Page 1 LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES When mounting Solibro modules from generation G1.4 or higher with the specified clamps, section 2 "Planning" of the valid installation and operation manual under: 2.2 "Requirements on the clamp system for unframed modules" 2.2 "Requirements on the clamp system for framed modules" 2.3 "Mounting options" must be observed. CLAMPS FOR UNFRAMED MODULES [SL2] SOLIBRO CLAMP - SC1 (120 mm) Manufacturer: Alumero Article number: Middle and End clamp are identical 22235 (black) 22234 (natural aluminum) MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa] TEST LOAD WITH SAFETY FACTOR γ m =1.5 [Pa] COMMENT SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm. Torque: 15-20 Nm Tensile load 1600 Tensile load 2400 SOLIBRO CLAMP - SC2 (120 mm) Manufacturer: Alumero Article number: Middle clamp 22285 (black) 22283 (natural aluminum) End clamp 22286 (black) 22284 (natural aluminum) MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa] TEST LOAD WITH SAFETY FACTOR γ m =1.5 [Pa] COMMENT SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm. Torque:10-18 Nm Tensile load 1600 Tensile load 2400 The required clamping force can be found in the manufacturer information. The fixing screws must be aligned with the substructure rails. The use of clamping systems which are not approved by Solibro can result in modules breaking, which in turn can cause electrical hazards that represent a danger to life and limb and a risk of material damage!

LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

  • Upload
    hakhanh

  • View
    232

  • Download
    2

Embed Size (px)

Citation preview

Page 1: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 1LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

When mounting Solibro modules from generation G1.4 or higher with the specified clamps, section 2 "Planning" of the valid installation and operation manual under:2.2 "Requirements on the clamp system for unframed modules" 2.2 "Requirements on the clamp system for framed modules" 2.3 "Mounting options" must be observed.

CLAMPS FOR UNFRAMED MODULES [SL2]

SOLIBRO CLAMP - SC1 (120 mm)

Manufacturer: Alumero Article number:Middle and End clamp are identical22235 (black)22234 (natural aluminum)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm.Torque: 15-20 NmTensile load 1600 Tensile load 2400

SOLIBRO CLAMP - SC2 (120 mm)

Manufacturer: Alumero Article number:Middle clamp22285 (black)22283 (natural aluminum)End clamp22286 (black)22284 (natural aluminum)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2 Point mounting Pressure load 1600 Pressure load 2400 Use a minimum rail width of 40 mm.Torque:10-18 NmTensile load 1600 Tensile load 2400

The required clamping force can be found in the manufacturer information. The fixing screws must be aligned with the substructure rails.

The use of clamping systems which are not approved by Solibro can result in modules breaking, which in turn can cause electrical hazards that represent a danger to life and limb and a risk of material damage!

Page 2: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 2LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

CLAMPS WITH GROUNDING FUNCTION FOR FRAMED MODULES [SL2-F]

ALUMERO (50 mm)

Manufacturer: Alumero Article number:Grounding middle clamp without screw17171 (black)15446 (natural aluminum)End clamp without screw17211 (black)17210 (natural aluminum)Grounding plate16075

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point and linear mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm.

Tensile load 1600 Tensile load 2400

ALUMERO (50 mm)

Manufacturer: Alumero Article number:Grounding middle clamp with screw18023 (black)16482 (natural aluminum)End clamp with screw18012 (black)17753 (natural aluminum)Grounding plate16075

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point and linear mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm.

Tensile load 1600 Tensile load 2400

ESDEC BV (40 mm)

Manufacturer: Esdec Article number:Grounding middle clamp100-3952 (black)100-3020 (natural alumi-num)End clamp100-3950 (black)100-3003 (natural alumi-num)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Clamps and screws should only be used as a system with Esdec substructure rails.

Tensile load 1600 Tensile load 2400

Page 3: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 3LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

HATICON (40/35 mm)

Manufacturer: HatiCon Article number:Grounding middle clamp with grounding clipAK II Klick 30-400-048 (natural aluminum)End clampAK II Klick 30-400-006 (natural aluminum)AK II Klick 30-400-053 (black)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Only use as a system with Haticon substructure rails.

Tensile load 1600 Tensile load 2400

HILTI MSP-PR-EC (50 mm)

Manufacturer: Hilti Article number:Grounding middle clamp with grounding plateMSP-PR-MC blackMSP-PR-MC (natural aluminum)End clampMSP-PR-EC blackMSP-PR-EC (natural aluminum)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Only use as a system with Hilti substructure rails.

Tensile load 1600 Tensile load 2400

MOUNTING SYSTEMS (40/35 mm)

Manufacturer: Mounting Systems

Article number:Grounding middle clamp 700-0120 (natural aluminum)End clamp 702-0282 (black)702-0280 (natural aluminum)Grounding clip 814-0543

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Only use as a system with Mounting Systems sub-structure rails.Tensile load 1600 Tensile load 2400

Page 4: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 4LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

SCHLETTER (100 mm)

Manufacturer: Schletter

Article number:Grounding middle clamp135001-900 (black)135001-000 (natural aluminum)Grounding end clamp130001-930 (black)130001-030 (natural aluminum)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point and linear mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm. For black anodized clamps, a screw with lock-ing serration must be used.

Tensile load 1600 Tensile load 2400

SCHLETTER (100 mm)

Manufacturer: Schletter

Article number:Grounding middle clamp135002-900End clamp131001-930

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Only use as a system with Rapid2+ substructure rails.

Tensile load 1600 Tensile load 2400

SUNFIXINGS (70 mm)

Manufacturer: Sunfixings

Article number:Grounding middle clamp with grounding disc220001End clamp220024

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point and linear mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm.

Tensile load 1600 Tensile load 2400

Page 5: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 5LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

SUPORTS (50 mm)

Manufacturer: Suports Article number:Grounding middle clampOS2 (natural aluminum)End clampZS2 (natural aluminum)

MODULE MOUNTING DESIGN LOAD PERMISSIBLE STATIC LOAD [Pa]

TEST LOAD WITH SAFETY FACTOR γm=1.5 [Pa]

COMMENT

SL2-F Point mounting Pressure load 3600 Pressure load 5400 Use a minimum rail width of 40 mm.

Tensile load 1600 Tensile load 2400

Page 6: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 6LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

MOUNTING SYSTEMS FOR UNFRAMED MODULES [SL2]

SOLIBRO

Manufacturer Solibro

Name of system Slide-In

Type of application Free field

Mounting variant Detachedly elevated system

Permitted inclination 20° – 60°

Design Load for pressure and tensile* 2,000 Pa

Test Load for pressure and tensile 3,000 Pa

Notice Mounting on a separate substructure

The currently valid installation manual for the Solibro Slide-In System must be applied for the installation. The requirements of the substructure can be requested from the respective manufacturer.

*Max. system load equals max. permissible module load

SUNBEAM

Manufacturer Sunbeam

Name of system Sunbeam symmetrical

Type of application Flat roof with the max. inclination of 5°

Mounting variant Elevated system

Mounting inclination 2 x 10°

Design Load for pressure and tensile* 1,600 Pa

Test Load for pressure and tensile 2,400 Pa

Type of roof** Flat roof: foil and bitumen roof

Roof connection** Flat roof: ballasting

*Max. system load equals max. permissible module load* * Mounting according to the manufacturer‘s specification and the structural

analysis

CALYXO

Manufacturer Calyxo

Name of system MX

Type of application Flat roof, tilted roof

Mounting variant Parallel to the roof

Design Load for pressure and tensile* 2,000 Pa

Test Load for pressure and tensile 3,000 Pa

Type of roof** Flat roof: foil and bitumen roofTilted roof: tile and metal roof

Roof connection** Flat roof: ballastingTilted roof: roof penetration

*Max. system load equals max. permissible module load* * Mounting according to the manufacturer‘s specification and the structural

analysis

Page 7: LIST OF APPROVED CLAMPS AND MOUNTING …solibro-solar.com/fileadmin/image/05_News_Downloads/Downloads/... · Mounting variant Parallel to the roof Design Load for pressure and tensile*

Page 7LIST OF APPROVED CLAMPS AND MOUNTING SYSTEMS FOR MODULES OF THE SL2 AND SL2-F SERIES

SOLIBRO GMBHOT Thalheim, Sonnenallee 32–3606766 Bitterfeld-Wolfen, Germany

EMAIL [email protected] www.solibro-solar.com

Subj

ect t

o al

tera

tions

. © S

olib

ro G

mbH

Lis

t of a

ppro

ved

clam

ps a

nd m

ount

ing

syst

ems_

SL2_

2017

-12_

Rev1

5_EN

MOUNTING SYSTEMS FOR FRAMED MODULES [SL2-F]

K2

Manufacturer K2 Systems

Name of system Dome D 800

Type of application Flat roof with the max. inclination of 5°

Mounting variant Elevated system

Mounting inclination 2 x 10°

Design Load for pressure and tensile* 2,000 Pa

Test Load for pressure and tensile 3,000 Pa

Type of roof** Flat roof: foil and bitumen roof

Roof connection** Flat roof: ballasting

*Max. system load equals max. permissible module load* * Mounting according to the manufacturer‘s specification and the structural