1
System Brief THE A+ SYSTEM OF COMPONENTS • Genie ® 760™ Low Volume Direct Drive™ Probe • Genie ® Heated Regulators™: Model GHR™ or JTR-H™ • Genie ® GV4 Vaporizer Liquid Sampling Vaporization Introduction Analytically Correct Engineered Systems™ are tailored to the specific application and designed to ensure sample integrity is maintained throughout the sample extraction and preconditioning process. The Liquid Sample Vaporizer System is an ACES™ tailored for mixtures with a wide range of components like Natural Gas Liquids (NGL) and Liquified Petroleum Gas (LPG). A key component of this system is the Model GV4 Genie ® Vaporizer™. The GV4 is designed to flash vaporize a liquid sample solely by heat transfer without pressure reduction, and without disassociation of the phases or fractionation of the components. The regulator in the system reduces the pressure only after the sample has been completely vaporized by the GV4 and is heated primarily to compensate for the Joule Thomson (JT) cooling effect associated with reducing the pressure of a vapor. A typical Vaporizing Pressure Regulator (VPR) uses sudden pressure reduction to vaporize the sample and provides heat transfer to support the phase change caused by the pressure drop. This approach may be well suited to a relatively low flow rate of a pure liquid or a mixture with very few and very similar components but cannot be used to vaporize a relatively high flow rate of mixtures with a wide range of components, like Y-Grade. The Liquid Sample Vaporizer System is composed of the GV4 and either the Model GHR™ or the Model JTR-H Heated Regulator™ in the small footprint of our patented vertical ACES™ insulated enclosure, all mounted on the Low Volume version of our Model 760™ probe. The low internal volume of the 760™ probe and the capillary inlet on the GV4 help to ensure minimal sample delay from the volume of liquid in the sample path. This system is especially well suited to supplying gas analyzers that can be field mounted near to the sample tap. ACES Component Breakdown Genie 760™ Low Volume Direct Drive™ Probe Known to be one of the safest, most versatile probes on the market, the Model 760LV is adjustable in length and low volume. The Model 760LV can be easily inserted into and retracted from a pressurized source through a full port valve up to 48”. This non-membrane tipped probe allows for liquids to drain back into the source after separation by our Genie Membrane Technology™ at the probe outlet. Genie GV4 Vaporizer™ has greater heat transfer capacity than most vaporizing regulators and is designed to flash vaporize wide boiler mixtures that cannot be vaporized by a heated regulator. Its design allows the liquid sample to be maintained at pressure, above the bubble point and temperature below the bubble point until it enters the flash chamber where it is instantaneously vaporized without pressure reduction. The proportional temperature controller on the GV4 is mounted outside of the enclosure where the temperature display panel can be easily viewed. Genie Heated Regulators™ A+ pressure regulators are designed specifically for sample handling. The self-limiting heater block on either the single-stage GHR™ or the 4 stage JTR-H™ compensates for the JT cooling effect to help preserve sample integrity. Insulated Enclosure This case allows the sample pressure and enclosure temperature to be monitored at a quick glance, without having to remove the enclosure. For complete access to system components, one or both sides can be completely removed. US Patents 10,073,013; 10,613,004; 10,627,320; 10,627,322; 10,641,687. ACES™, Analytically Correct Engineered Systems™, Genie ® , Genie ® Membrane Technology™, Genie ® Membrane Probes™ Genie ® Heated Regulators™, 760™, GHR™, JTR-H™ are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners. © 2012 A+ Corporation. All rights reserved. SCC-LiquidSamplingVaporization-SB_101421 Power Requirement: 250W @ 110 VAC or 1,000W @ 240 VAC Electrical Connection Approval: CSA: Class 1, Division 1, Group C&D, T3 Should you need assistance in selecting the appropriate components for your application, please consult the factory.

Liquid Sampling - geniefilters.com

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Liquid Sampling - geniefilters.com

System Brief

THE A+ SYSTEM OF COMPONENTS

• Genie® 760™ Low Volume Direct Drive™ Probe

• Genie® Heated Regulators™:

Model GHR™ or JTR-H™

• Genie® GV4 Vaporizer

Liquid SamplingVaporization Introduction

Analytically Correct Engineered Systems™ are tailored to the specific application and designed to ensure sample integrity is maintained throughout the sample extraction and preconditioning process. The Liquid Sample Vaporizer System is an ACES™ tailored for mixtures with a wide range of components like Natural Gas Liquids (NGL) and Liquified Petroleum Gas (LPG). A key component of this system is the Model GV4 Genie® Vaporizer™. The GV4 is designed to flash vaporize a liquid sample solely by heat transfer without pressure reduction, and without disassociation of the phases or fractionation of the components. The regulator in the system reduces the pressure only after the sample has been completely vaporized by the GV4 and is heated primarily to compensate for the Joule Thomson (JT) cooling effect associated with reducing the pressure of a vapor. A typical Vaporizing Pressure Regulator (VPR) uses sudden pressure reduction to vaporize the sample and provides heat transfer to support the phase change caused by the pressure drop. This approach may be well suited to a relatively low flow rate of a pure liquid or a mixture with very few and very similar components but cannot be used to vaporize a relatively high flow rate of mixtures with a wide range of components, like Y-Grade.

The Liquid Sample Vaporizer System is composed of the GV4 and either the Model GHR™ or the Model JTR-H Heated Regulator™ in the small footprint of our patented vertical ACES™ insulated enclosure, all mounted on the Low Volume version of our Model 760™ probe. The low internal volume of the 760™ probe and the capillary inlet on the GV4 help to ensure minimal sample delay from the volume of liquid in the sample path. This system is especially well suited to supplying gas analyzers that can be field mounted near to the sample tap.

ACES Component Breakdown

Genie 760™ Low Volume Direct Drive™ Probe Known to be one of the safest, most versatile probes on the market, the Model 760LV is adjustable in length and low volume. The Model 760LV can be easily inserted into and retracted from a pressurized source through a full port valve up to 48”. This non-membrane tipped probe allows for liquids to drain back into the source after separation by our Genie Membrane Technology™ at the probe outlet.

Genie GV4 Vaporizer™ has greater heat transfer capacity than most vaporizing regulators and is designed to flash vaporize wide boiler mixtures that cannot be vaporized by a heated regulator. Its design allows the liquid sample to be maintained at pressure, above the bubble point and temperature below the bubble point until it enters the flash chamber where it is instantaneously vaporized without pressure reduction. The proportional temperature controller on the GV4 is mounted outside of the enclosure where the temperature display panel can be easily viewed.

Genie Heated Regulators™

A+ pressure regulators are designed specifically for sample handling. The self-limiting heater block on either the single-stage

GHR™ or the 4 stage JTR-H™ compensates for the JT cooling effect to help preserve sample integrity.

Insulated Enclosure This case allows the sample pressure and enclosure temperature to be monitored at a quick glance, without having to remove the enclosure. For complete access to system components, one or both sides can be completely removed.

US Patents 10,073,013; 10,613,004; 10,627,320; 10,627,322; 10,641,687. ACES™, Analytically Correct Engineered Systems™, Genie®, Genie® Membrane Technology™, Genie® Membrane Probes™ Genie® Heated Regulators™, 760™, GHR™, JTR-H™ are trademarks or registered trademarks of A+Corporation, LLC. All other referenced trademarks are the property of their respective owners. © 2012 A+ Corporation. All rights reserved. SCC-LiquidSamplingVaporization-SB_101421

Power Requirement: 250W @ 110 VAC or 1,000W @ 240 VACElectrical Connection Approval: CSA: Class 1, Division 1, Group C&D, T3 Should you need assistance in selecting the appropriate components for your application, please consult the factory.