LIQUID CYLINDER GAS MANIFOLD SERIES 240 LEFT RIGHT HEADER HEADER GAS SERIES (# cylinders) (# cylinders) SERVICE 240 72” Pigtails 72” Pigtails 320-Carbon Dioxide 240HP 1L72 1R72 540-Oxygen 2L72 2R72 580-Argon/Nitrogen 3L72 3R72 326-Nitrous Oxide } Integral alarm system is standard, remote A/V alarm optional } Electrical - 115 volts (AC) } Maximum inlet pressure 350 PSIG } Manifold outlet - 1/2” NPT } Relief valve outlet - 1/4” NPT } 240 Series for use with 235 PSIG relief valve liquid cylinders } 240HP Series for use with 350 PSIG relief valve liquid cylinders } 72" Pigtails are standard The Series 240 Manifold is designed specifically to regulate and monitor vaporized gas from cryogenic cylinders. The Series 240 Manifold prevents downtime by automatically switching over when the primary cylinder bank is depleted. A green light indicates the primary cylinder service bank is functioning and the reserve cylinder bank is ready for service. A red light signals that the system has changed over and one or both banks are depleted. The user resets the primary bank by turning the lever. ORDERING INFORMATION FOR GAS WITHDRAWAL FROM CRYOGENIC GAS CYLINDERS THE HARRIS PRODUCTS GROUP www.harrisproductsgroup.com 1.800.241.0804

LIQUID CYLINDER GAS MANIFOLD - The Harris Products Group In India

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

LIQUID CYLINDER GAS MANIFOLDSERIES 240

Left Right headeR headeR gas seRies (# cylinders) (# cylinders) seRvice

240 72” Pigtails 72” Pigtails 320-Carbon Dioxide 240HP 1L72 1R72 540-Oxygen 2L72 2R72 580-Argon/Nitrogen 3L72 3R72 326-Nitrous Oxide

}Integral alarm system is standard, remote A/V alarm optional

}Electrical - 115 volts (AC)

}Maximum inlet pressure 350 PSIG

}Manifold outlet - 1/2” NPT

}Relief valve outlet - 1/4” NPT

}240 Series for use with 235 PSIG relief valve liquid cylinders

}240HP Series for use with 350 PSIG relief valve liquid cylinders

}72" Pigtails are standard

The Series 240 Manifold is designed specifically to regulate and monitor vaporized gas from cryogenic cylinders. The Series 240 Manifold prevents downtime by automatically switching over when the primary cylinder bank is depleted. A green light indicates the primary cylinder service bank is functioning and the reserve cylinder bank is ready for service. A red light signals that the system has changed over and one or both banks are depleted. The user resets the primary bank by turning the lever.

ORDERING INFORMATION

FOR GAS WITHDRAWAL FROM CRYOGENIC GAS

CYLINDERS

the haRRis PROdUcts gROUPwww.harrisproductsgroup.com1.800.241.0804

PROFESSIONAL PRODUCTS ...SUPERIOR RESULTS

Gas Distribution Systems

240 TYPICAL LAYOUT

MaxiMUM MaxiMUM inteRnaL adjUstabLe MOdeL inLet PRessURe fLOW Rate Line RegULatOR deLiveRy Range

240 235 PSIG 750 SCFH 40-85 PSIG

240HP 350 PSIG 800 SCFH 40-180 PSIG

240 SPECIFICATIONS

the haRRis PROdUcts gROUPwww.harrisproductsgroup.com 1.800.241.0804

240 SERIESSWITCHOVER MANIFOLD

240 SERIESSWITCHOVER MANIFOLD

240 SERIESSWITCHOVER MANIFOLD

10

1213

864

2

50

-30

0

100

150

200-1

0

LEFT BANK

EMPTY NORMAL EMPTY NORMAL

RIGHT BANK

Power Supply

72" Pigtails

Remote Alarm(Optional)

16”

9.25”