Upload
chris-findlay
View
227
Download
1
Embed Size (px)
DESCRIPTION
Lindapter - Free Connection Design Service 822
Citation preview
A) Assembly Data (allowable loads, torque requirements and Factor of Safety used)
B) Customised project name or detail
Email your connection requirement (contact details on next sheet)
Example shown: GC001-1
As part of its extensive Technical Support service Lindapter, the innovators of steelwork clamping fixings, can design a bespoke connection based on your specific requirements free of charge in three easy steps...
C) Your company name
D) Lindapter product requirements
E) Additional dimensions for precise fabrication
Lindapter’s experienced Engineers will devise your
bespoke solution
1 32
An Engineer will send you a design drawing,
as below> >
Each drawing includes:
www.Lindapter.com
FREE CONNECTION DESIGNAvailable now from
A
Top BeamFlange Width = 203mmFlange Thickness = 15.5mm
Lower BeamFlange Width = 102mmFlange Thickness = 6mm
10
116
218
180
270
14 THRU
DETAIL A SCALE 1 : 1.5
M12 x 70mm Long Setscrew, PropertyClass 8.8, with Class 8 Nut & Plain Washer
Lindapter B12L Clamp
Lindapter A12M Clamp
Lindapter P1S12 Packer
Location Plate
For combined loadings the current relevant nationalstandard should be taken into consideration
Assembly Data:
Static Tensile SWL = 23.2 kNFactor of Safety :
5 : 1Static Slip Resistance
SWL = 1.4 kNFactor of Safety :
5 : 1Lindapter Fastener Tightening Torque = 69 Nm
GC001-1 Connection Details
DWG. NO. REV.
CHECKEDDATE
WEIGHT:
DESCRIPTIONREV. DATEBY
0SWXXXX-XX
CUSTOMER ENQUIRY N.
SCALE:
www.lindapter.com
DRAWN
DRAWING TITLE
GENERAL NOTES:
NOT TO SCALE
DO NOT SCALE THIS DRAWING1.THIS DRAWING AND THE COPYRIGHT THEREIN ARE THE 2.PROPERTY OF LINDAPTER INTERNATIONAL. IT IS ISSUED ON THE CONDITION THAT IT MUST NOT BE USED, COPIED, DISTRIBUTED OR EXHIBITED WITHOUT WRITTEN PERMISSION AND CONSENT. THE DRAWING MUST ALSO NOT BE USED FOR ANY OTHER PURPOSE THAN WHICH IT IS ISSUED.IT IS THE RESPONSIBILITY OF THE ENGINEER TO PERFORM 3.ALL REASONABLE CHECKS ON THE SUPPORTING AND SUPPORTED MEMBERS. THAT IS LOCAL TO THE CONNECTION AND THE LINDAPTER COMPONENTS, BOTH FOR THE LOAD APPLIED AND THE CLAMPING FORCE GENERATED FROM THE TIGHTENING OF THE FASTENERS.WHERE NECESSARY WORKMANSHIP FOR ITEMS SHOWN 4.ON THIS DRAWING SHOULD COMPLY WITH THE RELEVANT SECTIONS OF THE NATIONAL STRUCTURAL STEELWORK SPECIFICATION (NSSS) FOR BUILDING CONSTRUCTION 5TH EDITION CE MARKING VERSION.IF FELT NECESSARY, WHERE EXCESSIVE VIBRATION MAY BE 5.A CONCERN, IT IS ACCEPTABLE FOR CERTAIN TYPES OF ANTI-VIBRATION LOCKING DEVICES SUCH AS, BUT NOT LIMITED TO, PROPRIETARY WASHERS AND NUTS TO BE USED WITH LINDAPTER COMPONENTS AND/OR ASSEMBLIES; SPRING WASHERS OF ANY TYPE ARE NOT RECOMMENDED. IN THESE SITUATIONS IT IS IMPORTANT THAT THE MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. NO GUARANTEES OR WARRANTIES ARE IMPLIED.
DRAWING NOTES:
PROJECT
DIMENSIONS ARE IN MM1.TOLERANCES: 2.ANGULAR: BEND 3.MATERIAL COATINGS TO BE SPECIFIED BY THE ENGINEER 4.
A
B
D
C
E
FREE CONNECTION DESIGNAvailable now from
Why choose Lindapter?Lindapter’s experienced team of Engineers ensures an efficient specification process from start to finish, aiming to create a bespoke solution that delivers on cost and performance, ultimately saving you time and money.
Lindapter provides drawings in 2D and interactive 3D formats as well as CAD files that are suitable to import into all major software applications. We can even customise the drawing by adding your project name so it’s ready for plan checking immediately, thereby reducing design time.
Simply provide the details listed on the right and Lindapter will do the rest!
If you would like Lindapter to design your bespoke connection, please make sure to have the following:
1. Member sizes to be used or flange width and thickness
2. Loads to be resisted (eg. 10kN tension and 15kN slip)
3. General arrangement sketch and/or verbal description*
4. Project Name / Title (optional)
5. Project Location (optional)
*See Lindapter’s catalogue for different configurations
The Service Free connection design is just a small part of Lindapter’s service. We offer comprehensive design and support, tailoring our products to your application:
££ £3D>
Free design proposal
2D / 3D drawings
Quotation SupplyInstallation guidance
> > >
>> For simple Girder Clamp connections try the Assembly Selector today at www.Lindapter.com <<
Contact Lindapter today
Tech Support: [email protected] / General Enquiries: [email protected] / T: +44 (0) 1274 521444
What we require...
www.Lindapter.com
A
Top BeamFlange Width = 203mmFlange Thickness = 15.5mm
Lower BeamFlange Width = 102mmFlange Thickness = 6mm
10
116
218
180
270
14 THRU
DETAIL A SCALE 1 : 1.5
M12 x 70mm Long Setscrew, PropertyClass 8.8, with Class 8 Nut & Plain Washer
Lindapter B12L Clamp
Lindapter A12M Clamp
Lindapter P1S12 Packer
Location Plate
For combined loadings the current relevant nationalstandard should be taken into consideration
Assembly Data:
Static Tensile SWL = 23.2 kNFactor of Safety :
5 : 1Static Slip Resistance
SWL = 1.4 kNFactor of Safety :
5 : 1Lindapter Fastener Tightening Torque = 69 Nm
GC001-1 Connection Details
DWG. NO. REV.
CHECKEDDATE
WEIGHT:
DESCRIPTIONREV. DATEBY
0SWXXXX-XX
CUSTOMER ENQUIRY N.
SCALE:
www.lindapter.com
DRAWN
DRAWING TITLE
GENERAL NOTES:
NOT TO SCALE
DO NOT SCALE THIS DRAWING1.THIS DRAWING AND THE COPYRIGHT THEREIN ARE THE 2.PROPERTY OF LINDAPTER INTERNATIONAL. IT IS ISSUED ON THE CONDITION THAT IT MUST NOT BE USED, COPIED, DISTRIBUTED OR EXHIBITED WITHOUT WRITTEN PERMISSION AND CONSENT. THE DRAWING MUST ALSO NOT BE USED FOR ANY OTHER PURPOSE THAN WHICH IT IS ISSUED.IT IS THE RESPONSIBILITY OF THE ENGINEER TO PERFORM 3.ALL REASONABLE CHECKS ON THE SUPPORTING AND SUPPORTED MEMBERS. THAT IS LOCAL TO THE CONNECTION AND THE LINDAPTER COMPONENTS, BOTH FOR THE LOAD APPLIED AND THE CLAMPING FORCE GENERATED FROM THE TIGHTENING OF THE FASTENERS.WHERE NECESSARY WORKMANSHIP FOR ITEMS SHOWN 4.ON THIS DRAWING SHOULD COMPLY WITH THE RELEVANT SECTIONS OF THE NATIONAL STRUCTURAL STEELWORK SPECIFICATION (NSSS) FOR BUILDING CONSTRUCTION 5TH EDITION CE MARKING VERSION.IF FELT NECESSARY, WHERE EXCESSIVE VIBRATION MAY BE 5.A CONCERN, IT IS ACCEPTABLE FOR CERTAIN TYPES OF ANTI-VIBRATION LOCKING DEVICES SUCH AS, BUT NOT LIMITED TO, PROPRIETARY WASHERS AND NUTS TO BE USED WITH LINDAPTER COMPONENTS AND/OR ASSEMBLIES; SPRING WASHERS OF ANY TYPE ARE NOT RECOMMENDED. IN THESE SITUATIONS IT IS IMPORTANT THAT THE MANUFACTURER'S INSTALLATION INSTRUCTIONS ARE FOLLOWED. NO GUARANTEES OR WARRANTIES ARE IMPLIED.
DRAWING NOTES:
PROJECT
DIMENSIONS ARE IN MM1.TOLERANCES: 2.ANGULAR: BEND 3.MATERIAL COATINGS TO BE SPECIFIED BY THE ENGINEER 4.