LIGHTPLANE 3.5 Wet Location Recessed (LP3.5RWL and LP3.5RTWL) Installation Guide SAVE THESE INSTRUCTIONS Tel: (510) 489-2530 Fax: (650) 2490412 web: www.alwusa.com IMPORTANT SAFETY INSTRUCTIONS When installing or using this suspended fixture basic safety precautions should be followed Read ALL INSTRUCTIONS before installing fixture. •This fixture is intended for installation in accordance with the National Electric Code and Local and State Codes and must be installed by a licensed electrical contractor. •DANGER - RISK OF SHOCK AND FIRE - DISCONNECT POWER BEFORE INSTALLATION •THIS FIXTURE IS FOR INSTALLATION IN NON-INSULATED CEILINGS ONLY

LIGHTPLANE 3.5 Wet Location Recessed …...1.TURN OFF POWER at fuse box before installing fixture. 2. 3 Connect 1/4-20 all thread rod to building structure to both Endcaps of the fixture,

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: LIGHTPLANE 3.5 Wet Location Recessed …...1.TURN OFF POWER at fuse box before installing fixture. 2. 3 Connect 1/4-20 all thread rod to building structure to both Endcaps of the fixture,

LIGHTPLANE 3.5 Wet Location Recessed(LP3.5RWL and LP3.5RTWL)Installation Guide

SAVE THESE INSTRUCTIONSTel: (510) 489-2530 Fax: (650) 2490412 web: www.alwusa.com

IMPORTANT SAFETY INSTRUCTIONS

When installing or using this suspended fixture basic safety precautions should be followed

Read ALL INSTRUCTIONS before installing fixture.

•This fixture is intended for installation in accordance with the National Electric Codeand Local and State Codes and must be installed by a licensed electrical contractor.

•DANGER - RISK OF SHOCK AND FIRE - DISCONNECT POWER BEFORE INSTALLATION

•THIS FIXTURE IS FOR INSTALLATION IN NON-INSULATED CEILINGS ONLY

Page 2: LIGHTPLANE 3.5 Wet Location Recessed …...1.TURN OFF POWER at fuse box before installing fixture. 2. 3 Connect 1/4-20 all thread rod to building structure to both Endcaps of the fixture,

Instructions for a single section unit:

1. TURN OFF POWER at fuse box before installing fixture.

2.

3

Connect 1/4-20 all thread rod to building structure to both Endcaps of the fixture, secure rod with a nut. Adjust fixture mounting height for lens to be flush with ceiling finished plane. Endcaps will stick out below the ceiling. Attach conduit to 1/2” NPT threaded end cap.

4 Connect the luminary neutral (white) to the supply neutral,connect the luminary line wire (black) to the supply linewire. Fasten ground wire(s) (Green) to ground wire.

5 Push wires into wirebody and secure REFLECTOR ASSEMBLYwith SCREWS (DO NOT PINCH THE WIRES BETWEEN THE PARTS)

6 Turn on power.

SAVE THESE INSTRUCTIONSTel: (510) 489-2530 Fax: (650) 2490412 web: www.alwusa.com

1/4-20thread rod and nut by others

LIGHTPLANE 3.5 Wet Location Recessed(LP3.5RWL)Wallboard Installation Guide

NOTICE: For proper installation, have a qualified electrician install this product. Before installation of any luminary onto an electrical junction box, be sure to disconnect power. This luminary must be wired and grounded in accordance with National Electric Code, local codes and ordinances. Wire supply connections must be made with U.L. or ETL approved connectors. Check that luminary voltage and building voltage are the same.

CAUTION: EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINARY. USE OF SOFT GLOVES AND PADDED MATERIALS ARE RECOMMENDED DURING HANDLING TO AVOID MARRING THE FINISH

MAINTENANCE:1. Remove LENS to access lamp and power supply.2. To remove LENS, unscrew both LENS END CAPSand use suction cup to pull LENS out of WIRE-BODY.3. To access power supply, remove reflector. 4. Before re-attaching LENS, ascertain gasketchannel is clean. Push LENS firmly inside gasketchannel. Secure LENS by using both LENS END CAPS.

4"

3 1116 "

Building Structure

3 1316 "

FinishedCeiling Opening

Page 3: LIGHTPLANE 3.5 Wet Location Recessed …...1.TURN OFF POWER at fuse box before installing fixture. 2. 3 Connect 1/4-20 all thread rod to building structure to both Endcaps of the fixture,

web: www.alwusa.comTel: (510) 489-2530 Fax: (650) 249-0412

2.

3.

4.

5.

6.

1. Remove LENS and REFLECTOR ASSEMBLY on thefixture that connects to the building wire. Set partsaside.

2. Place provided o-rings around both ends of nipple.

3. On the inside of the joiner endcap, firmly tightenprovided nylon nut using a 1” socket or wrench ontonipple.

4. Install endcap onto desired fixture section usingexisting mounting points and hardware.

5. Mate both fixture sections together.

6. Place o-ring onto the nipple from inside of thefixture section.

7. Repeat step 3. and tighten down until minimumgap between fixture sections is achieved.(1/16” Nominally)

8. Push wires into wirebody and secure REFLECTORASSEMBLY with SCREWS (DO NOT PINCH THE WIRESBETWEEN THE PARTS)

9. Fluorescent fixtures, install lamp sockets backinto extrusion. Make sure markings on extrusion and socket are aligned to ensure correct socket distance.

LIGHTPLANE 3.5 Wet Location Recessed(LP3.5RWL)Joiner Endcap Installation Instructions

NOTICE:For proper installation, have a qualified electrician install this product. Before installation of any luminaire onto an electrical junction box, be sure to disconnect power. This luminaire must be wired and grounded in accor-dance with the National Electrical Code, local codes, and ordinances. Wire supply connections must be made with UL approved connectors. Check that luminaire voltage and building voltage are the same.

CAUTION:EXERCISE SPECIAL CARE AND SAFETY WHILE INSTALLING AND SERVICING LUMINAIRE. USE OF SOFT GLOVES AND PADDED DURING HANDLING TO AVOID MARRING THE FINISH.

1.

O-Ring

Seat nipple into endcap

1/2" NPS Nylon Nut

INSTRUCTION:Before proceeding, read maintenance instruction to access wiring compartment inside fixture. For Fluorescent fixtures, remove lamp sockets to access connecting hardware.