LIFEPAK 12 PRESENTATION

Embed Size (px)

Citation preview

Page 1: LIFEPAK 12  PRESENTATION

Life Pack 12Life Pack 12

Biphasic technology. Biphasic technology.

Compatible with QUIK-COMBO™ Compatible with QUIK-COMBO™ pacing/ defibrillation/pacing/ defibrillation/

ECG electrodes. ECG electrodes.

Page 2: LIFEPAK 12  PRESENTATION

Life Pack 12Life Pack 12What can it do?What can it do?

ECG MONITORINGECG MONITORING

ACQUIRING A 12-LEAD ECGACQUIRING A 12-LEAD ECG

PULSE OXIMETRYPULSE OXIMETRY

AUTOMATED EXTERNAL DEFIBRILLATIONAUTOMATED EXTERNAL DEFIBRILLATION

MANUAL DEFIBRILLATIONMANUAL DEFIBRILLATION

SYNCHRONIZED CARDIOVERSIONSYNCHRONIZED CARDIOVERSION

NONINVASIVE PACINGNONINVASIVE PACING

NIBP MONITORINGNIBP MONITORING

THERAPY WARNINGSTHERAPY WARNINGS

Page 3: LIFEPAK 12  PRESENTATION

CONTROLS AND INDICATORS

Page 4: LIFEPAK 12  PRESENTATION

MO-1 DMAT

Controls and Indicators - Area 1 ON Button: Switches power on / off

Energy Select: Selects energy levels in manual shock. Press the up or down button.

Charge: When the defibrillator is

charging a charging bar appears and a ramping tone sounds.

Shock: Discharges the shock to the patient. If shock is not delivered in 60 sec, the stored energy is removed. If you change the charge energy, the energy is removed and you will need to recharge.

Sync: Use for cardioversion.

Page 5: LIFEPAK 12  PRESENTATION

MO-1 DMAT

Controls and Indicators - Area 1 Battery Charge: Indicates that at

least one battery is installed and being charged by an AC/DC power adapter

Service: Indicates that the internal self-check failed

Advisory: Activates continuous patient surveillance system (CPSS) which monitors the patient for potential shockable rhythm

Analyze: Activates the Shock Advisory

System (SAS). SAS is a ECG analysis system that will advise the user if it detects a shockable or nonshockable rhythm

Page 6: LIFEPAK 12  PRESENTATION

Controls and Indicators - Area 2

Pacer: Switches pacer on and off indicated by light. Once the ECG confirm a triangle sensor marker on the top of the QRS, if not change leads or adjust.

Rate: Press the button (10ppm) or rotate the dial (5ppm)to the desired rate

Current: Press the button for 10 increments or rotate the dial for 5 increments until capture occurs. Pacer indicator will flash with each pacing stimulus.

Pause: Push and hold this button to pause pacing. Pacing will continue at 25% of set rate. Release button and pacing will continue at set rate

Page 7: LIFEPAK 12  PRESENTATION

Controls and Indicators - Area 3

Lead: Select or change ECG leads. Press the lead button again or rotate the dial to the desired lead. Display will be on the right side of the screen.

Size: Press the button a display will appear. Either press again or rotate the dial to the desired ECG size.

NIBP: Press the button to activate. Cuff should inflate 30mmHg higher then pt systolic pressure.

Alarms: Can be configured on or off. Alarms are set to a predetermined limits. They can be adjusted.

Page 8: LIFEPAK 12  PRESENTATION

Controls and Indicators – Area 3

Options: Press the button and a screen will display Patient, Pacing, Date/Time, Alarm volume, Archives, Print and User Test.

Events: Press the event button and scroll thru the screen selecting the choice from Adenosine, ASA, Atropine, Bicarb, CPR, Dopamine, Epinephrine, Intubation for example. By pressing the button a timestamp will appear on the code summary.

Home Screen: Pressing this button will return you to from any overlay screen to the home screen EXCEPT during AED analysis or manual defibrillation charging or shocking.

Page 9: LIFEPAK 12  PRESENTATION

Controls and Indicators - Area 4

CO2 tubing connector: Open the connection door and connect the Capnography tubing next connect to the patient.

SPO2 Cable Connector: When plugged in performs a 17 sec calibration and 3 sec self test. Measures SpO2 between 50% and 100%.

NIBP Tubing Connector: When connect there is a 3 sec self test. Typically takes pressure within 40 sec. but no longer 120 sec.

ECG Cable Connector: Connect the trunk lead and the limb leads and/or the 12 leads are connected the trunk lead.

Page 10: LIFEPAK 12  PRESENTATION

MO-1 DMAT

Controls and Indicators - Area 4

Speaker

Printer

Therapy Cable Connector: Connect cable to therapy electrodes or to the paddles.

Page 11: LIFEPAK 12  PRESENTATION

Controls and Indicators - Area 5

12 Lead: Press to initiate acquisition of a

12 lead ECG.

Transmit: Capability to transmit patient data.

Code Summary: Pressing button will print the code summary with critical events that were recorded.

Print: Press the button to start and to stop the printer.

Page 12: LIFEPAK 12  PRESENTATION

MO-1 DMAT

Controls and Indicators - Area 6

Page 13: LIFEPAK 12  PRESENTATION

ECG MONITORINGECG MONITORING

ECG Monitoring - Patient ECG cable

ECG Monitoring – Combo Electrode

Selecting ECG leas and size

Adjusting systole volume

Alarm settings

Page 14: LIFEPAK 12  PRESENTATION

SpO2 MONITORINGSpO2 MONITORING

Adjust Sensitivity normal/highAdjust Sensitivity normal/high

Average Sensing time 4,8,12 and 16 SecAverage Sensing time 4,8,12 and 16 Sec

Hi light and select SpO2 volumeHi light and select SpO2 volume

Cover sensor if excessive ambient light presentCover sensor if excessive ambient light present

SpO2 waveform displays on channel 2SpO2 waveform displays on channel 2

Page 15: LIFEPAK 12  PRESENTATION

AUTOMATED EXTERNAL DEFIBRILLATIONAUTOMATED EXTERNAL DEFIBRILLATION

AED – Do not place electrodes in AED – Do not place electrodes in Anterior and posteriorAnterior and posterior

AED – Not for Pediatric less than AED – Not for Pediatric less than 8Yrs8Yrs

Press Advisory – (CPSS On)Press Advisory – (CPSS On)

Press Analyze – (SAS On)Press Analyze – (SAS On)

AED – Motion detector Auto onAED – Motion detector Auto on

Page 16: LIFEPAK 12  PRESENTATION

AED SAMPLE VIDEOAED SAMPLE VIDEO

AED SAMPLE VIDEO.MSWMM

Page 17: LIFEPAK 12  PRESENTATION

MANUAL DEFIBRILLATIONMANUAL DEFIBRILLATION

Press Energy Select or Rotate Press Energy Select or Rotate energy select dialenergy select dial

Press charge – Press shockPress charge – Press shock

Shock not pressed in 60sec. Auto Shock not pressed in 60sec. Auto

discharge internallydischarge internally

Page 18: LIFEPAK 12  PRESENTATION

SYNCHRONIZED CARDIOVERSIONSYNCHRONIZED CARDIOVERSION

ECG through Therapy Electrode, Select ECG through Therapy Electrode, Select PaddlesPaddles

Press sync – LED blinks each QRSPress sync – LED blinks each QRS

Confirm triangle sense markerConfirm triangle sense marker

Press Energy Select or Rotate energy Press Energy Select or Rotate energy select dialselect dial

Press charge – Confirm ECG rhythm and Press charge – Confirm ECG rhythm and available energyavailable energy

Press and hold shock button until Press and hold shock button until discharge occurs with next QRS complexdischarge occurs with next QRS complex

Page 19: LIFEPAK 12  PRESENTATION

NONINVASIVE PACINGNONINVASIVE PACING

Demand and Nondemand PacingDemand and Nondemand Pacing

Place ECG and Therapy electrodesPlace ECG and Therapy electrodes

Press pacer. Confirm LED illuminatesPress pacer. Confirm LED illuminates

Press rate or rotate selector set PPMPress rate or rotate selector set PPM

Press current or rotate selector – electrical Press current or rotate selector – electrical capture occurredcapture occurred

View intrinsic rhythm press and hold pass.View intrinsic rhythm press and hold pass.(25%)(25%)

Page 20: LIFEPAK 12  PRESENTATION

NONINVASIVE BLOOD PRESSURENONINVASIVE BLOOD PRESSURE

Initial Inflation pressureInitial Inflation pressure

Manual single measurementManual single measurement Timer controlled measurementTimer controlled measurement

Pulse not displayed when spo2 / ECG activePulse not displayed when spo2 / ECG active

Page 21: LIFEPAK 12  PRESENTATION

THERAPY WARNINGSTHERAPY WARNINGS Do not clean with ketones or other flammable agents. Do not clean with ketones or other flammable agents.

Do not autoclave or sterilize this device accessoriesDo not autoclave or sterilize this device accessories

Do not use this device in the presence of flammable Do not use this device in the presence of flammable gases or anesthetics. Use care when operating this gases or anesthetics. Use care when operating this device close to oxygen sources (such as bag-valve-device close to oxygen sources (such as bag-valve-mask devices or ventilator tubing). Turn off gas mask devices or ventilator tubing). Turn off gas source or move source away from patient during source or move source away from patient during defibrillation.defibrillation.

Avoid operating device near cauterizers, diathermy Avoid operating device near cauterizers, diathermy equipment, or cellular phones. Maintain equipment equipment, or cellular phones. Maintain equipment separation of at least 1.2 mtrs.separation of at least 1.2 mtrs.

Page 22: LIFEPAK 12  PRESENTATION

CODE SUMMARY REPORTCODE SUMMARY REPORT

Page 23: LIFEPAK 12  PRESENTATION

THANK YOUTHANK YOU