11
LHC Beam screen: impact of the weld on the wakes Preliminary analysis E. Metral, G. Rumolo, B. Salvant, C. Zannini

LHC Beam screen: impact of the weld on the wakes

  • Upload
    topper

  • View
    64

  • Download
    0

Embed Size (px)

DESCRIPTION

LHC Beam screen: impact of the weld on the wakes. Preliminary analysis E. Metral, G. Rumolo, B. Salvant, C. Zannini. Overview. Model studied Comparing structure within and without weld Numerical noise. Model studied. LHC design as it is built and installed. - PowerPoint PPT Presentation

Citation preview

Page 1: LHC Beam screen:  impact of the weld on the wakes

LHC Beam screen: impact of the weld on the wakes

Preliminary analysis

E. Metral, G. Rumolo, B. Salvant, C. Zannini

Page 2: LHC Beam screen:  impact of the weld on the wakes

Overview

• Model studied

• Comparing structure within and without weld

• Numerical noise

Page 3: LHC Beam screen:  impact of the weld on the wakes

Model studiedLHC design as it is built and installed

weld

In this step we are only interested to understand the effect of the weld .

Page 4: LHC Beam screen:  impact of the weld on the wakes

Model studied

a

ba=46.4 mmb=36.8 mmw=2 mmL=1m

w

L

Page 5: LHC Beam screen:  impact of the weld on the wakes

Overview

• Model studied

• Comparing structure within and without weld

• Numerical noise

Page 6: LHC Beam screen:  impact of the weld on the wakes

Comparing within and without weld

For a displacement in x of 5 mm the horizontal dipolar wake with weld seems to be five time larger than the wake without weld

Page 7: LHC Beam screen:  impact of the weld on the wakes

Horizontal dipolar wake with weld versus displacement

The displacement is considered negative if it is in the direction opposite the weld

The horizontal dipolar wake with weld for a displacement in x of -5 mm seems to be twenty-five time larger than the wake with weld for a displacement in x of 5 mm

Page 8: LHC Beam screen:  impact of the weld on the wakes

For a displacement in x of -5 mm the horizontal dipolar wake with weld seems to be five time smaller than the wake without weld

Page 9: LHC Beam screen:  impact of the weld on the wakes

Changing the transverse dimension of the weld w

Ssteel corresponds to w/2

Increasing the transverse dimension of the weld the horizontal dipolar wake increase almost linearly.

Page 10: LHC Beam screen:  impact of the weld on the wakes

Overview

• Model studied

• Comparing structure within and without weld

• Numerical noise

Page 11: LHC Beam screen:  impact of the weld on the wakes

Numerical noise• The high value of conductivity that we need to simulate determines a very small signal and then

the simulation results (longitudinal wake) are very noisy. The transverse wakes are obtained integrating this wake using the Panofsky-Wenzel theorem. In the frame of these issues can we consider reliable the results shown previously?

• To verify the correctness of the results we can simulate the worst case for the noise: the structure without weld. We can simulate the structure with two different conductivity high and low conductivity and then rescaling the results at the same conductivity and compare them. The results obtained with low conductivity are more reliable because the numerical noise is insignificant. To obtain a good comparison it means that even though the signal is very noisy the code is able to make a good integration and we can be more confident of the results obtained.

Decreasing the conductivity the results increase as the square root of the conductivity

Sigmacopper is the conductivity of the cold Copper σ=1.82e9 S/m