PCR60 Cabinets

Cabinets are vertical laminar flow

workstations designed for installation on

standard laboratory benches, or on optional

floorstands.Theircompactdimensionsreduce

theneedforbenchspace.

Theyaredesignedandmanufactured

in Australia, and each unit is factory-tested

andcertifiedbyaNATA-registeredlaboratory.

PleaserefertoourStandardspage.

Verticallaminarairflowintheworkzone

createsabiologically-clean,particle-freework

environmentthatreducescrosscontamination

duringsamplepreparation.

Description

AESEnvironmentalmaintainsanISO

9001:2008qualitymanagementsystemto

ensureprocessandproductconformance.

Applications

In order to obtain reliable results

in clinical and diagnostic PCR work, it is

necessary to maintain an ultra-clean work

environment that is free from biological and

particulate contamination. Additionally, UV

radiationisneededtodestroypost-procedure

contaminants.Clyde-ApacPCR60TMcabinets

provideahighdegreeofprotectionforproducts

andapparatusinPCRapplications.

ThePCR60RTMisavariantofthebasic

PCRcabinet,andprovidesprotectionforboth

personnelandproducts.

Partial recirculation of air leaving the work

zone reduces air turbulence and extends

HEPAfilterlife.

A short-wavelength UV lamp

inactivates residualDNA/RNAparticles, thus

reducing carryover contamination. The UV

operates onlywith the fan switched off, and

theUV shield should be fittedwhenever the

UVlampisinuse.

PCR60R Cabinets

In addition to the product protection

afforded by PCR60 cabinets, the PCR60R

provides protection for personnel. This is

achievedbyanairbarrierattheworkopening

andHEPAfiltrationoftheexhaustair.

Anairbarrierbetweentheoperatorand

theworkzoneismaintainedbyaflowofroom

airintoagrilleintheworkopening.Allpositive

pressure zones are surrounded by negative

pressure zones, so as to contain hazardous

aerosols.

Page 3: Laminar Flow Cabinets - Clyde-Apac Air Filtrationclydeapac.com.au › pdf › PCR series.pdfLaminar Flow Cabinets Sterile airflow UV radition control contmination in PCR work PCR60

Construction

Cabinet The sturdy steel housing is finished

in a durable baked enamel that has been

developed for laboratory equipment. The

workzoneand the removableUVshieldare

constructed in easy-to clean 304 stainless-

steel.

Fan A direct-drive fan is regulated by

a speed controller to enable airflow to be

maintainedthroughfilterlife.Thefanandfilter

plenumsaredesigned toprovideultra-quiet,

low-vibrationoperation.

HEPA Filters Clyde-ApacMicrosealTMHEPA filters,

which are certified by Quality Assurance

ServicesunderLicenceNo.2515tocarrythe

SAAStandardsMarkforcompliancewithAS

4260.

Each filter is individually certified to achieve

efficiency of not less than 99.995% to the

stringentBS3928SodiumFlametest,andto

beleak-freeinaccordancewithAS1807.6.

Testing is conducted in a NATA registered

laboratory and a NATA-endorsed test label,

beinganextractof the test report, isaffixed

toeachfilter.Positive-pressurefiltersealsare

surroundedbynegativepressurezones,thus

enhancingthereliabilityofthefilterinstallation.

Pre-Filters On PCR60 cabinets, an easily

accessed, washable pre-filter on top of the

unitarrestsnot less than90%ofparticles5

micronandlarger,thusprolongingHEPAfilter

life.

ElectricalCabinets operate on single-phase 240V, 50

Hzpowerviaa10Aoutlet.Alowvoltagetouch

control panel is located on the front of the

cabinetwith thestatusofswitched functions

indicated by LEDs. The PCR60R has an

audible alarm and warning LED to signify

reduction of airflow. An integral fluorescent

lamphousingreducesheatbuild-upnearthe

operator and provides lighting intensity of

>800 lux at thework surface. TheUV lamp

produces radiation at 254 nm wavelength.

Theelectricalsystemofthecabinetcomplies

withAustralianStandardAS3100.

Page 4: Laminar Flow Cabinets - Clyde-Apac Air Filtrationclydeapac.com.au › pdf › PCR series.pdfLaminar Flow Cabinets Sterile airflow UV radition control contmination in PCR work PCR60

ModelCatalogue

No.Overall

Dimensions (mm)Work Zone

Dimensions (mm)Weight

(kg)

W H D W H D

PCR60 2015800 676 1000 690 576 575 525 70

PCR60R 2015810 676 1055 690 576 575 525 86

Physical Data

Note: PCR60R cabinets have top exhaust. The minimum exhaust discharge clearance recommended is 500 mm.

› Germicidal UV lamp and safety shield

› Glare-free fluorescent lighting

› Lowvoltagetouchcontrols

› Easy to clean stainess steel work area

› Airflow alarm (PCR60R)

› Comprehensiveoperationandmaintenancemanual

› Made in Australia with 2 year warranty

› Hourmeter

› Manometer

› Power Outlet

› Servicetapsforair,gasandvacuum

› Floor Stand

› Trolley

› Fumigation Adaptors (PCR60R)

Standard Features Options

Page 5: Laminar Flow Cabinets - Clyde-Apac Air Filtrationclydeapac.com.au › pdf › PCR series.pdfLaminar Flow Cabinets Sterile airflow UV radition control contmination in PCR work PCR60

Operation

TheSERVICE PREFILTER LEDindicatesthattheprefilterneedscleaningorreplacement.

TheRUNswitchoperatesthefan.

The LIGHT switch operates thefluorescent lamps in the workzone.Thelampsmaybeoperatedindependentlyofthefan.

TheUVswitchoperatestheoptionalUVlamp.Thisswitchisonlyactivewhenallotherfunctionsareswitchedoff.

ThePOWER switchoperatestheoptionalworkzoneGPO.

TheMAINS LEDindicatesthatelectricalpowerisconnectedtothecabinet.

PCRSeriescabinetsarefittedwithalow-voltage,touch-controlpanel

tooperatestandardcabinetfunctionsageneralpurposepoweroutlet(GPO)

andultraviolet(UV)lamp.

Light-emittingdiodes(LEDs)indicatethestatusofswitchablefunctions,

theprefilterandmainselectricalpower.

Switchesareofthemembranetypewithatoggleaction.Amomentary

touchontheswitchpadwillswitchtheselectedfunctiononoroff.

Personnel Protection

PCR60cabinetsprovideprotection

for products or experiments, but do

not protect personnel from aerosols of

hazardousmaterialsthatmaybehandled

inthecabinet.ForPCRapplicationswhere

protection for products and personnel is

required,PCR60Rsafetycabinetsshould

beconsidered.

WARNING

Page 6: Laminar Flow Cabinets - Clyde-Apac Air Filtrationclydeapac.com.au › pdf › PCR series.pdfLaminar Flow Cabinets Sterile airflow UV radition control contmination in PCR work PCR60

© 2018 AES Environmental | Bulletin No. 20F.02.18 AES170 REV2In keeping with our policy of continuing product improvement, we reserve the right to alter specifications without notice.

› HWSSeriesTMhorizontallaminarflowcabinets.

› VWSSeriesTMverticallaminarflowcabinets.

› BSC2000TMClassIbiologicalsafetycabinets. › BH2000TMClassIIbiologicalsafetycabinets.› Recirculatingfumecabinets.› TFPTMSeriesHEPAfiltercleanroommodules.

› ExhaustCaptureHoodforCytotoxicSuite.› Passthroughhatches.

Other ProductsOn-Site Testing

PCR Series cabinets are factory

tested and certified by a NATA-Accredited

laboratory.Additional testingandcertification

isrecommendedasfollows:

› Onsitepriortouse

› Aftermaintenance› Afterfilterreplacement› Afterre-location› Atleastannually› Inspecialcircumstances,e.g.iffaultyoperationissuspected.

9A Pembury Rd, Minto 2566Ph 1300 550 116 F 1300 550 [email protected]

www.aesenvironmental.com.au

AESEnvironmental,aNATAregistered

laboratory, provides comprehensive on-site

maintenance,testingandcertificationservices

forsafetycabinets,laminarflowworkstations,

clean-rooms and HEPA filter installations.

This service is available from fully-equipped

laboratories in major Australian centres.

Similar services are provided by appointed

serviceagentsinotherregions.

NATA Registered

The Company

AESEnvironmentalisanAustralianownedmanufacturingbusinessproducingproductsunder

Clyde-Apac,EmailAirHandlingandVokesbrandnamesforindustriesthatareasvariedasindustrialplants,

commercialbuildings,powerstations,foodprocessing,healthcare,scienceandelectronics.AESEnvironmental

considerstheAustralianStandardsasacorecomponentofitsproductmixandhasdevelopedanexportmarket

in25countries,promotingAustralianStandards,engineeringandmanufacturingsolutions.AESEnvironmental,

atrustedmanufacturercapableofdeliveringreliableproductsolutionstohighly-criticalapplications,wherethe

controlofhazardousairbornecontaminationisoftencriticaltoprocessandpersonnel.