Upload
yoyosmet
View
218
Download
0
Embed Size (px)
Citation preview
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 1/16
132
BRUCIATORICALDAIE MURALI E TERRA A GAS
GRUPPI TERMICI IN GHISA E IN ACCIAIOGENERATORI DI ARIA CALDA
TRATTAMENTO ACQUA CONDIZIONAMENTO
01/01Cod. 97.00237.0
LAMBORGHINI CALOR S.p.A. VIA STATALE, 342
44040 DOSSO (FERRARA)ITALIA
TEL. ITALIA 0532/359811 - EXPORT 0532/359913FAX ITALIA 0532/359952 - EXPORT 0532/359947
Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senzaobbligo di preavviso tutte le modifiche che ritiene più opportuno per l'evoluzione del prodotto.
EM 35- E EM 40/2- E EM 40/M- E
BRUCIATORI AD ARIA SOFFIATA PERCALDAIE NORMALIIT
GB
F
D
ES
3
8
13
18
23
MANUALE PER L'UTENTE
Alla cortese attenzione del Sig. INSTALLATORE Consegnare il presente manuale d'uso all'UTENTE
A l’attention de l’INSTALLATEUR:Remettre la présente notice d’utilisation à l’UTILISATEUR
A la atención del Sr. INSTALADOR:Entregar el presente manual para el uso al USUARIO
For the attention of the INSTALLATION TECHNICIAN:Make sure that this manual is handed over to the USER
USER MANUAL
FORCED DRAUGHT BURNERS FORSTANDARD BOILERS
BRULEURS A AIR SOUFFLE POUR
CHAUDIERES CLASSIQUES
NOTICE D’UTILISATION
Les illustrations et les données contenues dans la présente notice ont été fournies à titre indicatif et n’engagent pa s. La Société LAMBORGHINIse réserve le droit d’apporter, sans obligation de préavis, toutes les modifications qu’elle estime nécessaires pour l’amélioration du produit.
The illustrations and data given are indicative and are not binding. LAMBORGHINI reserves the right to make any changesconsidered necessary for the improvement of the product without the obligation of providing prior notice.
MANUAL PARA EL USUARIO
Las ilustraciones y los datos son indicativos y no comprometen. LAMBORGHINI se reserva el derecho de realizar sin preaviso todas las modificaciones que estime oportuno para la evolución del producto
Hinweis für den INSTALLATEUR:Überreichen Sie bitte dieses Handbuch dem Benutzer
BENUTZERHANDBUCH
GEBLÄSEBRENNER FÜR NORMALEHEIZKESSEL
QUEMADORES DE AIRE FORZADO PARACALDERAS NORMALES
Die Abbildungen und die angegebenen Daten haben erläuternden Charakter und sind nicht verbindlich. Die Fa. LAMBORGHINI behält sichdas Recht vor, ohne Vorankündigung alle Änderungen vorzunehmen, die sie zur Weiterentwicklung des Produkts für angezeigt hält.
0 4 4 4 3
5 2 0 0 0
- V I
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 2/16
2 31
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 3/16
3
INDICE PAGINA
NORME GENERALI 4DESCRIZIONE 6
ACCENSIONE 6
SPEGNIMENTO 6
MANUTENZIONE 6
IRREGOLARITÀ DI FUNZIONAMENTO 7
Gentile Utente...... Lei è entrato in possesso di un prodotto, frutto di un’accurata progettazione e di metodi costruttivi
all’avanguardia, in grado di garantire la massima affidabilt à, sicurezza di funzionamento ed economiadi esercizio. Legga attentamente quanto descritto in questo manuale, per conoscere tutto ciò che concerneil funzionamento del prodotto. I ns. Centri Assistenza “LAMBORGHINI SERVICE”, sono a Sua disposizioneper garantire una QUALIFICATA MANUTENZIONE ed una TEMPESTIVA ASSISTENZA.
LAMBORGHINI CALORECLIMA
Per l’installazione e per il posizionamento della caldaia:RISPETTARE SCRUPOLOSAMENTE LE NORME LOCALI VIGENTI.
30
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 4/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 5/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 6/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 7/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 8/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 9/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 10/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 11/16
11
DESCRIPTION
These are forced-draught burners, with gas/air mix at the combustion head; one and two-stage versions, as well as modulating versions, are available. The burners are completely automatic and equipped with controlsassuring maximum safety. They can be combined with any type of chamber whether in negative or positivepressure, within the foreseen working range. The gas part is oversized so it can work even when the mainsupply pressure is very low. All the components can be easily inspected without having to disconnect from themain gas supply. The burners are equipped with a cover which means they are particularly compact, soundproof and safeguarded.
START UP
Open the gas cock and set the desired temperature on the boiler adjustment thermostat. The equipment willstart the automatic check-out test and then the burner will ignite automatically. Should the start up not perform- lock-out button lit - push this button so that the equipment can repeat the automatic check-out test.
PROLONGED SWITCHING OFF
If the burner should remain inactive at length close the gas cock and turn off the power by acting on the mainswitch.
MAINTENANCE
Skilled staff has to perform yearly the following operations:
Check the valve inside tightness.
Filter cleaning.
Fan and head cleaning. Check the position of the ignition electrode tips as well as the control electrode. Calibrate the air and gas pressure switches. Check the combustion by means of CO2-CO-fumes temperature bearings. Check all the gaskets and seal tightness.
22
BETRIEBSSTÖRUNGEN
DEFEKT URSACHE ABHILFE
1 DER BRENNER SPRINGTNICHT AN.
A. Kein Strom.B. Keine Gaszufuhr zum Brenner.
A. Die Schmelzsicherungen der Stromversorgungsleitungüberpr üfen.Die Schmelzsicherung desBrenners und der elektrischenSteuereinheit überpr üfen.Die Leitung der Thermostaten
und des Gasdruckw ächtersüberpr üfen.
B. Die Öffnung der Absperr- vorrichtungen auf der Versorgungsleitung überpr üfen.
2 DER BRENNER SPRINGT AN,ES BILDET SICH KEINEFLAMME, DER BRENNERGEHT AUF STÖRUNG.
A. Die Gasventile öffnen sichnicht.
B Zwischen den Elektroden-spitzen erfolgt keineEntladung.
C. Es erfolgt keine Freigabe durchden Druckw ächter.
A. Den Technikerverst ändigen.B. Den Technikerverst ändigen.C. Den Technikerverst ändigen.
3 DER BRENNER SPRINGT AN,DIE FLAMME BILDET SICH,DER BRENNER GEHT AUFSTÖRUNG.
A. Fehlende oder unzureichendeFlammenermittlung durch dieÜberwachungselektrode.
A Den Techniker verst ändigen.
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 12/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 13/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 14/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 15/16
7/24/2019 Lamborghini_em35 e Em40 2 e Em40 m e (Uso)
http://slidepdf.com/reader/full/lamborghiniem35-e-em40-2-e-em40-m-e-uso 16/16