    01

    09/2008 by Krone Filter GmbH, subject to change

    Krone Filter GmbH

    Herbert-Ludwig-Str. 12-14

    28832 Achim

    Tel: +49 (0)4202 97 69 23

    Fax: +49 (0)4202 97 69 27

    [email protected]

    www.krone-filter.com

    Applications

    The KRF backflush filter is a versatile self-cleaning,

    maintenance-free filter for liquid media.

    Brief description and operation

    The electronic control monitors the differential pres-

    sure applied to the strainer by means of a differenti-

    al pressure switch. If the preset differential pressure

    of 0.2 - 2 bar (depending on the design) is attained,

    the cleaning function is triggered. In addition the

    cleaning function can be triggered by a timer ormanually at the touch of a button, depending on the

    operating conditions.

    The contaminated medium flows through the flange

    marked inlet into the filter. The contaminated me-

    dium flows through the filter insert from the inside

    to the outside and escapes from the flange marked

    outlet as cleaned medium.

    The reversible flow nozzle lowers the interior of the

    strainer insert and simultaneously the contaminant

    outlet valve is opened so that a pressure gradient oc-curs relative to the atmosphere. This initiates strainer

    cleaning. The filter is designed in such a manner that

    the drop in pressure for optimized cleaning can be

    kept extremely low.

    Filtration is not interrupted during the backflush

    process in a system. After the set flushing period

    elapses the contaminant outlet valve closes automa-

    tically.

    Installation

    The filter is installed in pipes by means of flanges.Ensure that the standard version of the filter is

    installed vertically and a mechanically tension-free

    manner without additional loads. The medium must

    flow in the direction specified on the housing. Incor-

    rect installation can cause separator malfunctions.

    The contaminant outlet pipe must be laid with no

    pressure, without cross section reduction, without an

    ascending gradient, and, if possible with a descen-

    ding gradient.

    KRFBACKFLUSH FILTER

    DN 32 DN 400 (ANSI 1 1/2 20)

    PN 16 PN 40

    Fully automatic backflush

    filter DN 32-200

    Backflush filter

    with double insert

  • 7/30/2019 Krf_Datasheet_en.pdf

    2/4

    02

    09/2008 by Krone Filter GmbH, subject to change

    Technical data

    We manufacture and deliver additional design and material variants on customer request.

    We request your enquiry.

    Standard version Special version or optional extras equipment

    Filter insert 20 3000 m

    Filter catch Cover with bolts and nuts -

    Venting device Screw Ball valve

    Drain unit Screw Ball valve

    Connections Flange in accordance with DIN 2632/ Form C ANSI or in accordance with customer specifica-tions

    Materials: e.g. ANSI

    Housing GGG-40 1.4571, H II steel, CrNi, 1.0425

    Seals NBR PTFE / FPM, other

    Perforated plate/meshCleaning nozzle

    1.4301/1.4404GGG 40/oG-CuSN 10/12

    As specif ied by customer

    Drain valve - St, Ms, A 2, A 4

    Electric gear motor 3 x 400 V / 50 Hz protection class IP 65 As specified by customer

    Control not attachedWith transformer 500 V / 400 V / 230 V 50Hz / 60 Hz, protection class IP 65, program-mable

    Attached on the f ilter as specif iedby the customer

    Contaminant outlet valve Rg 5, A 4Electro-pneumatic (230 V - 6 bar) /(24 V - 6 bar)

    Protection class IP65Electrical Ex protection version, ATEX

    Surface treatment

    Interior:

    Steel housingGGG-40

    without epoxy-resin paint, hard rubber, ECTFE, glassbead blasted

    Surface treatment

    Exterior:

    Housing, GGG-40,Steel housing steel

    Synthetic resin paint RAL 5010 blue -

    Stainless steel housing Pickled and passivated Glass bead blasted

  • 7/30/2019 Krf_Datasheet_en.pdf

    3/4

    Technical data and dimensions 1

    03

    DNFilter-surface

    cm2a b *c e f g h k l

    ap-prox.

    mp q u z Weight

    kgCapacity

    liters

    Oil/emulsion

    throughputat

    60 m3/h

    Viscosit yWater

    at200 m3/h

    32 530 108 73 43 75 14 50 740 190 14 378 126 1/2" 84 660 39 2.1 5 5

    40/50 1.310 113 120 49/61 75 14 90 810 285 13 410 176 1/2" 115 750 54 5.5 10 15

    65 3.100 130 160 77/90 123.5 14 100 938 350 12 550 270 1/2" 190 900 97 19 25 35

    806.280 195 250

    *90150 18 140 1.125 650 20 560 346 3/4" 250 1.180 205 45 50 90

    100 100

    125 10.390 236 280 125 175 23 200 1.300 760 20 650 400

    1"

    270 1.600 250 80 85 130

    15014.750 276 350

    *169225 23 200 1.421 820 20 740 516 350 1.680 495 154 120 350

    200 200

    250-800 Larger units on request

    Krone backwash filter with single insert

    09/2008 by Krone Filter GmbH, subject to change

    Design pressure 16 bar

    Test pressure 32 bar

    Design temperature 180 C

  • 7/30/2019 Krf_Datasheet_en.pdf

    4/4

    Technical data and dimensions 2

    04

    DNFilter-surface

    cm2a b e f g h k

    approx.m

    approx.n

    p r s t u z kg Liters

    Oil/emulsion

    throughputat 60 m3/h

    Viscosit yWater

    at 200 m3/h

    125 11.050 169 320 335 12 x 18 850 1.230 770 350 240 406

    3/4" 1/4 1"

    400 1.500 240 7o 90 200

    200 18.050 202 365 335 12 x 18 992 1.490 820 410 270 457 450 1.755 320 110 145 395

    250 28.100 240 430 445 12 x 22 1.188 1.645 950 437 375 559 500 2.000 400 175 225 600

    300 38.500 282 500 515 1 6 x 26 1.230 1.820 1.070 490 410 650 1" 1/2" 11/2" 580 2.250 580 290 310 890

    350 53.500 305 550 550 20 x 22 1.462 1.920 1.170 515 470 750 1" 1/2" 11/2" 620 2.400 920 390 430 1.200

    Krone reversible filter with double sieve

    09/2008 by Krone Filter GmbH, subject to change

    KF-PCIII-08-2008-PP

    Perm. operating pressure 16 bar

    Test pressure Germ. Lloyd 24 barTest pressure PED 97/23 EG 23 bar

    Permissible operating pressure 120 C