7/30/2019 Krf_Datasheet_en.pdf
1/4
01
09/2008 by Krone Filter GmbH, subject to change
Krone Filter GmbH
Herbert-Ludwig-Str. 12-14
28832 Achim
Tel: +49 (0)4202 97 69 23
Fax: +49 (0)4202 97 69 27
www.krone-filter.com
Applications
The KRF backflush filter is a versatile self-cleaning,
maintenance-free filter for liquid media.
Brief description and operation
The electronic control monitors the differential pres-
sure applied to the strainer by means of a differenti-
al pressure switch. If the preset differential pressure
of 0.2 - 2 bar (depending on the design) is attained,
the cleaning function is triggered. In addition the
cleaning function can be triggered by a timer ormanually at the touch of a button, depending on the
operating conditions.
The contaminated medium flows through the flange
marked inlet into the filter. The contaminated me-
dium flows through the filter insert from the inside
to the outside and escapes from the flange marked
outlet as cleaned medium.
The reversible flow nozzle lowers the interior of the
strainer insert and simultaneously the contaminant
outlet valve is opened so that a pressure gradient oc-curs relative to the atmosphere. This initiates strainer
cleaning. The filter is designed in such a manner that
the drop in pressure for optimized cleaning can be
kept extremely low.
Filtration is not interrupted during the backflush
process in a system. After the set flushing period
elapses the contaminant outlet valve closes automa-
tically.
Installation
The filter is installed in pipes by means of flanges.Ensure that the standard version of the filter is
installed vertically and a mechanically tension-free
manner without additional loads. The medium must
flow in the direction specified on the housing. Incor-
rect installation can cause separator malfunctions.
The contaminant outlet pipe must be laid with no
pressure, without cross section reduction, without an
ascending gradient, and, if possible with a descen-
ding gradient.
KRFBACKFLUSH FILTER
DN 32 DN 400 (ANSI 1 1/2 20)
PN 16 PN 40
Fully automatic backflush
filter DN 32-200
Backflush filter
with double insert
7/30/2019 Krf_Datasheet_en.pdf
2/4
02
09/2008 by Krone Filter GmbH, subject to change
Technical data
We manufacture and deliver additional design and material variants on customer request.
We request your enquiry.
Standard version Special version or optional extras equipment
Filter insert 20 3000 m
Filter catch Cover with bolts and nuts -
Venting device Screw Ball valve
Drain unit Screw Ball valve
Connections Flange in accordance with DIN 2632/ Form C ANSI or in accordance with customer specifica-tions
Materials: e.g. ANSI
Housing GGG-40 1.4571, H II steel, CrNi, 1.0425
Seals NBR PTFE / FPM, other
Perforated plate/meshCleaning nozzle
1.4301/1.4404GGG 40/oG-CuSN 10/12
As specif ied by customer
Drain valve - St, Ms, A 2, A 4
Electric gear motor 3 x 400 V / 50 Hz protection class IP 65 As specified by customer
Control not attachedWith transformer 500 V / 400 V / 230 V 50Hz / 60 Hz, protection class IP 65, program-mable
Attached on the f ilter as specif iedby the customer
Contaminant outlet valve Rg 5, A 4Electro-pneumatic (230 V - 6 bar) /(24 V - 6 bar)
Protection class IP65Electrical Ex protection version, ATEX
Surface treatment
Interior:
Steel housingGGG-40
without epoxy-resin paint, hard rubber, ECTFE, glassbead blasted
Surface treatment
Exterior:
Housing, GGG-40,Steel housing steel
Synthetic resin paint RAL 5010 blue -
Stainless steel housing Pickled and passivated Glass bead blasted
7/30/2019 Krf_Datasheet_en.pdf
3/4
Technical data and dimensions 1
03
DNFilter-surface
cm2a b *c e f g h k l
ap-prox.
mp q u z Weight
kgCapacity
liters
Oil/emulsion
throughputat
60 m3/h
Viscosit yWater
at200 m3/h
32 530 108 73 43 75 14 50 740 190 14 378 126 1/2" 84 660 39 2.1 5 5
40/50 1.310 113 120 49/61 75 14 90 810 285 13 410 176 1/2" 115 750 54 5.5 10 15
65 3.100 130 160 77/90 123.5 14 100 938 350 12 550 270 1/2" 190 900 97 19 25 35
806.280 195 250
*90150 18 140 1.125 650 20 560 346 3/4" 250 1.180 205 45 50 90
100 100
125 10.390 236 280 125 175 23 200 1.300 760 20 650 400
1"
270 1.600 250 80 85 130
15014.750 276 350
*169225 23 200 1.421 820 20 740 516 350 1.680 495 154 120 350
200 200
250-800 Larger units on request
Krone backwash filter with single insert
09/2008 by Krone Filter GmbH, subject to change
Design pressure 16 bar
Test pressure 32 bar
Design temperature 180 C
7/30/2019 Krf_Datasheet_en.pdf
4/4
Technical data and dimensions 2
04
DNFilter-surface
cm2a b e f g h k
approx.m
approx.n
p r s t u z kg Liters
Oil/emulsion
throughputat 60 m3/h
Viscosit yWater
at 200 m3/h
125 11.050 169 320 335 12 x 18 850 1.230 770 350 240 406
3/4" 1/4 1"
400 1.500 240 7o 90 200
200 18.050 202 365 335 12 x 18 992 1.490 820 410 270 457 450 1.755 320 110 145 395
250 28.100 240 430 445 12 x 22 1.188 1.645 950 437 375 559 500 2.000 400 175 225 600
300 38.500 282 500 515 1 6 x 26 1.230 1.820 1.070 490 410 650 1" 1/2" 11/2" 580 2.250 580 290 310 890
350 53.500 305 550 550 20 x 22 1.462 1.920 1.170 515 470 750 1" 1/2" 11/2" 620 2.400 920 390 430 1.200
Krone reversible filter with double sieve
09/2008 by Krone Filter GmbH, subject to change
KF-PCIII-08-2008-PP
Perm. operating pressure 16 bar
Test pressure Germ. Lloyd 24 barTest pressure PED 97/23 EG 23 bar
Permissible operating pressure 120 C