23
Know what’s wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly Damage Keep Production Rates @ Highest Know Where, When, Why, How & What went wrong… Before Costly Damage Occurs! via Exact Location Fault Diagnostics

Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Embed Size (px)

Citation preview

Page 1: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Know what’s wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week

365 days a year.

A Simple Switch or Alarm will:Save Lives

Prevent Costly Damage

Keep Production Rates @ Highest

Know Where, When, Why, How & What went wrong…Before Costly Damage Occurs!

via

Exact Location Fault Diagnostics

Page 2: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Management System (CMS)Eliminates downtime and improves safety with a unique network of monitoring and protection devices --

without conduit or extra wiring.

Audible/Visible Prestart Warning

Pull Cord Switches

Dynamic Speed Monitoring

Multiple Conveyor Sequencing/Interlocking

Fault Location & Identification

Belt Underspeed and Slip

Belt Tear and Rip

Troughing and Return Belt Misalignment

PLC/PC Interface

Blocked Chute

CO Monitoring

Voice Communication

Control Room Interface

Pull CableContinuous monitoring from conveyor startup to shutdown identifies problems before they cause stoppage, damage, or personnel injury.

Modular design allows functions and devices to be added or removed to meet your specific needs.

No need for conduit or extra wiring. CTS Pull Cable supplies all the communications for the system, while also functioning as the pull cable. Other systems require individual switches to be hardwired through conduit.

Pinpoints faults by type and location so maintenance crews spend less time searching for the problem, and get vital equipment back online sooner.

Emergency stop, pre-start warning, and speech communications along the entire length of the conveyor enhance employee safety and equipment protection.

Interlocking and sequencing can control material flow. If a safety device stops a downstream conveyor, either upstream conveyors are stopped or flow is diverted to another conveyor. Once the problem is corrected, all conveyors are restarted sequentially, and the conveyor system is once again charged with material.

Central control room provides an overview of your entire operation, combining information from all controllers and field components, using Supervisory Control and Data Acquisition (SCADA) software.

Hardwire or RF radio communications. Controllers can use any industrial protocol or serial communications (RS-32, RS-422, or RS-485). Or, RF radio transmitters can be used to remove the need for hardwire communications.

Choose an Option or Next to Continue

NEXTExit Show

Page 3: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXT BACKConveyor Pull Cord Switches

Emergency stop switches stop the conveyor electrically at any point along the conveyor.

Heavy duty pulling mechanism compensates for temperature drifts, preventing false trips.

Electrical rotary switch allows the switch to be tripped manually. The electrical switch is a self-wiping rotary switch (not a microswitch), and consists of two normally open and two normally closed contacts.

Switch knob is padlockable in the "Off" position. Once the switch has been tripped, the knob latches in the "Off" position and must be manually reset in order to restart the conveyor.

High impact U.V. stabilized polycarbonate enclosure is rated IP 66 and D.I.P. (Dust Ignition Proof) degree of protection.

Recommended distance between switches is 330 feet (100.6 m).

Approved for use in non-hazardous locations by the Pennsylvania Dept. of Environmental Resources Mine Safety and Health Administration (MSHA).

Standard Pull Cord Switch

•All the standard features listed above.

•Self-wiping rotary switch (not a microswitch).

•Isolated mechanical and electrical sections.

•Heavy duty pulling mechanism eliminates false trips.

•Mounted on 330' (100.6 m) intervals.

•Corrosion-proof construction.

•For non-hazardous locations.

•For hazardous locations, must be installed in an intrinsically safe circuit.

Part Number: CTS 100

Main Page

Page 4: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Pre-Start Alarms

Enhance conveyor safety with audible and visible pre-start alarms.

High impact, UV stabilized polycarbonate enclosure rated at an IP 65 degree of protection.

Two audible alarms rated at 105dB each.

Can be used as a signaling device when equipped with a push button.

Intrinsically Safe AudioVisual Pre-Start Alarm

Standard Audio VisualPre-Start Alarm

Part Number: CTS 800 IS AVA Part Number: CTS 900 AVA

Flashing LED

Operating Voltage: 12-15 VDC(Intrinsically Safe Power Supply)

Current Consumption: 100 mA

Flashing Strobe Light

Operating Voltage:110-220 VAC

Current Consumption: 100 mA

BACKMain Page

Page 5: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXTConveyor Pull Cord Switches

Emergency stop switches stop the conveyor electrically at any point along the conveyor.

•Heavy duty pulling mechanism compensates for temperature drifts, preventing false trips.

•Electrical rotary switch allows the switch to be tripped manually. The electrical switch is a self-wiping rotary switch (not a microswitch), and consists of two normally open and two normally closed contacts.

•Switch knob is padlockable in the "Off" position. Once the switch has been tripped, the knob latches in the "Off" position and must be manually reset in order to restart the conveyor.

•High impact U.V. stabilized polycarbonate enclosure is rated IP 66 and D.I.P. (Dust Ignition Proof) degree of protection.

•Recommended distance between switches is 330 feet (100.6 m).

• Approved for use in non-hazardous locations by the Pennsylvania Dept. of Environmental Resources Mine Safety and Health Administration (MSHA).

Pull Cord Switch with Trip Light

•Standard switch features.

•Trip indicator light rated at 15W for locating the tripped switch.

•For use in a non-hazardous locations only.

Part Number: CTS 200L

BACKMain Page

Page 6: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXTConveyor Pull Cord Switches

Emergency stop switches stop the conveyor electrically at any point along the conveyor.

•Heavy duty pulling mechanism compensates for temperature drifts, preventing false trips.

•Electrical rotary switch allows the switch to be tripped manually. The electrical switch is a self-wiping rotary switch (not a microswitch), and consists of two normally open and two normally closed contacts.

•Switch knob is padlockable in the "Off" position. Once the switch has been tripped, the knob latches in the "Off" position and must be manually reset in order to restart the conveyor.

•High impact U.V. stabilized polycarbonate enclosure is rated IP 66 and D.I.P. (Dust Ignition Proof) degree of protection.

•Recommended distance between switches is 330 feet (100.6 m).

• Approved for use in non-hazardous locations by the Pennsylvania Dept. of Environmental Resources Mine Safety and Health Administration (MSHA).

Intrinsically Safe Pull Cord Switch

•Standard switch features.

•Trip indication LEDs.

•Hazardous and non-hazardous locations.

Part Number: CTS 300

BACKMain Page

Page 7: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXTConveyor Pull Cord Switches

Emergency stop switches stop the conveyor electrically at any point along the conveyor.

•Heavy duty pulling mechanism compensates for temperature drifts, preventing false trips.

•Electrical rotary switch allows the switch to be tripped manually. The electrical switch is a self-wiping rotary switch (not a microswitch), and consists of two normally open and two normally closed contacts.

•Switch knob is padlockable in the "Off" position. Once the switch has been tripped, the knob latches in the "Off" position and must be manually reset in order to restart the conveyor.

•High impact U.V. stabilized polycarbonate enclosure is rated IP 66 and D.I.P. (Dust Ignition Proof) degree of protection.

•Recommended distance between switches is 330 feet (100.6 m).

• Approved for use in non-hazardous locations by the Pennsylvania Dept. of Environmental Resources Mine Safety and Health Administration (MSHA).

Intrinsically Safe Switch with Pre-Start Alarm

•Standard switch features.

•Audible and visible pre-start alarms.

•Trip indication LEDs. Hazardous and non-hazardous locations.

Part Number: CTS 300 PSW

BACKMain Page

Page 8: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXTConveyor Pull Cord Switches: SpecificationsDimensions:

A. 7 13/16" (198 mm)

B. 6 1/8" (156 mm)

C. 7" (178 mm)

D. 5 1/2" (140 mm)

E. 5 1/2" (140 mm)Enclosure: I.P. 66 and DIP

Housing: High Impact Polycarbonate

Switch: Rated 16A at 500V standard10A at 500V-CSA2 normally open and 2 normally closed contacts

Hardware: 316 Stainless Steel

Approved by the Commonwealth of Pennsylvania - Department of Environmental Resources, Mine Safety and Health Administration (MSHA) for

use in non-hazardous locations. For use in hazardous locations, the CTS 100 must be installed in an intrinsically safe circuit.

Typical Connection Diagram

BACKMain Page

Page 9: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Management System ControllersThe Conveyor Management System's intelligent controllers monitor and supervise the entire operation.

The Safeline Circuit™ provides an extra level of safety. The Safeline Circuit in every CMS controller ensures that every safety device is operating at all times.

1. Field PCB

2. End Unit

3. Supply

4. Control

5. Safeline

6. Communication

A voltage inverting device used as the last unit in line transmits a negative voltage through a normally closed contact within each switch, back to the controller.

The controller monitors for the presence of the negative voltage, ensuring that the circuit is complete.

CMS Controllers Selection Chart

NEXT BACKMain Page

Engineering Capabilities

Our Electrical Controls Division can design, build, integrate and test a system customized for your needs, planned for the best cost efficiency and ease of operation.

As a company with many years of experience in the material handling industry, we understand the entire process rather than only the individual controls.

From 10 feet to 10 miles, we can provide the complete solution for your conveyor control needs.

Any level of service and components, literally from the pull cord switch to the SCADA screen.

Complete system pre-testing eliminates start-up delays. Because we provide both the field components and control units, we can completely test the entire system prior to shipment, eliminating delays due to incompatible components.

Page 10: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

NEXTSystem Capabilities CTS-ISP CTS-1000 CTS-3000

Pull Cable Y Y Y

Pre-Start Warning Y Y

Dynamic Speed Monitoring Y

Multi-Conveyor Sequencing Y Y

Fault Location and Identification Y

PLC/PC Interface Y Y

Belt Protection Devices CTS-ISP CTS-1000 CTS-3000

Belt Underspeed/Slip Y Y Y

Belt Tear Y Y Y

Belt Rip Y Y Y

Belt Misalignment Y Y Y

Blocked Chute Y Y Y

Pre-Start Warning Y Y

Conveyor Pull Cord Switches CTS-ISP CTS-1000 CTS-3000

Padlockable Safety Switch Y Y Y

Carbon Monoxide Monitoring Y Y

Audible/Visible Pre-Start Alarm Y Y

Voice Communication Y

BACK

CTS 3000: Head End Control Unit

CTS 1000: Conveyor Control Unit

Provides prestart warning alarm capability, either as stand-alone units or within CTS 300 PSW Pull Cord Switches.

CTS ISP: Power Supply and Line Check Unit

Provides emergency stop pull cord switch capability, using CTS Pull Cord Switches.

Main Page

Page 11: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

CTS 3000: Head End Control Unit

CTS 1000: Conveyor Control UnitProvides prestart warning alarm capability, either as stand-alone units or within CTS 300 PSW Pull Cord Switches.

Includes push buttons and a serial interface port for PC control.

Safeline Circuit for uncompromising safety. Intrinsically safe power supply allows our CTS Pull Cable to be used, eliminating the need for conduit.

CTS ISP: Power Supply and Line Check UnitProvides emergency stop pull cord switch capability, using CTS Pull Cord Switches.

Safeline Circuit for uncompromising safety.

Intrinsically safe power supply allows our CTS Pull Cable to be used, eliminating the need for conduit.

1. Motor Control Circuit

2. CTS IPS

3. Pull Cord Switches

4. End Unit

NEXT BACKMain Page

Programmable control unit with internal fault diagnostics controls, monitors, and supervises all safety and belt protection devices.

LCD display shows fault type and location, giving maintenance personnel the information they need to solve the problem quickly, minimizing downtime.

Transmits fault information to the control room with a fail safe interlock.

Safeline Circuit for uncompromising safety. Intrinsically safe power supply allows our CTS Pull Cable to be used, eliminating the need for conduit.

Page 12: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Management System ComponentsThe CMS system's modular design allows components to be added or removed to meet the needs of your specific

application. In addition to the pre-start alarms and monitors on this page, we provide a wide selection of Belt Protection Units, Pull Cord Switches, Pre-Start Alarms, and other devices.

Pre-Start Alarm with Termination EnclosureTwo enclosures mounted on a chassis plate that forms a canopy above the unit.Pre-Start Alarm: Our CTS 300 PSW Pull Cord Switch.

Emergency stop pull cord switch. Padlockable electrical rotary switch rated to 500V 16 amp. 2 audible prestart warning alarms. Trip indication LEDs. Replaceable resin-coated PC board.

Termination Enclosure: A resin coated PC board populated with spring-loaded type terminals for the cable connections and compression entry glands.Part Number: CTS 300 PSW/DC

Pre-Start Alarm with Speech CommunicationA "push to talk" speech communication unit enables operators and maintenance personnel to communicate from any point along the conveyor.

Pre-Start Alarm: A CTS 300 PSW Pull Cord Switch.Emergency stop pull cord switch. Padlockable electrical rotary switch rated to 500V 16 amp. 2 audible prestart warning alarms. Trip indication LEDs. Replaceable resin-coated PC board.

Speech Communication Unit: A PC board populated with terminals for pull cable connections equipped with 2 gland entries and a "push to talk" speech communication unit.

Part Number: CTS 300 PSW/DC/SC

NEXT BACKMain Page

Page 13: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Pre-Start Alarm with Carbon Monoxide Monitor

Pre-Start Alarm: A CTS 300 PSW Pull Cord Switch.

Emergency stop pull cord switch.

Padlockable electrical rotary switch rated to 500V 16 amp.

2 audible prestart warning alarms. Trip indication LEDs.

Replaceable resin-coated PC board.

CO Gas Monitor: Sounds an alarm at 100 PPM, and stops the conveyor at 400 PPM. The bottom enclosure consists of a PC board populated with terminals for pull cable connections equipped with 2 gland entries.

Part Number: CTS 300 PSW/DC/CO

Primary Device

Incorporates auxiliary equipment such as an emergency stop push button, take-up limit switches, fluid coupling temperature devices, blocked chute detectors, etc. into the Conveyor Management System's network.

The normally closed contact of the auxiliary equipment is connected to terminals in the unit's termination box.

If the auxiliary equipment is activated and the normally closed contact opens, the unit will stop the conveyor and latch in the "Off" position.

Part Number: CTS 400 PD

NEXT BACKMain Page

Page 14: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Temperature Monitor

Monitors the temperature of bearings, electrical motors, oil tanks, etc. The unit has two settings: one for alarm and one for stopping the conveyor.

Alarm settings range from 120° to 300° F, in 10° increments.

The unit is incorporated into the safety system of the conveyor by the pull cable. Part Number: CTS 500 TM

Vibration Monitor

Monitors the vibration of bearings, electrical motors, crushers, etc.

The unit's "accept" push button that is used to set the normal working vibration as the reference for alarm or trip.

The unit has two settings, one for alarm and one for stopping the conveyor. The alarm settings are set in increments of 5% from the normal vibration. The trip settings are set in increments of 5% above the alarm settings.

The unit is incorporated into the safety system of the conveyor by the pull cable.

Part Number: CTS 500 VM

NEXT BACKMain Page

Page 15: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Management System (CMS): Hardware

CMS Pull CableHigh-tensile braided steel cable with six internal conductors. The dual purpose cable serves as both the electrical and control cable for the entire system, as well as the emergency stop pull cable, eliminating the need for conduit and extra wiring. For added protection, the steel braiding is covered with U.V. stabilized flame retardant PVC.

Part Number: CTS PC

Termination KitCable clamp and steel hook terminates the pull cable between the pull-keys. The cable clamp grips the pull cord and the steel J-bolt is fastened to the pull cord switch pulling mechanism.

Part Number: CTS TK

Pull Cable CarrierCarries the pull cable between the pull cord switches (and to other various belt protection units). Pull cable carrier is mounted on the conveyor structure at 10 ft (254 mm) centers.

Part Number: CTS PCC

Conventional Hardware

Vinyl Coated Pull CordPart Number: CTS CRD

Galvanized ThimblePart Number: CTS THB

Galvanized Pull Cord FastenerPart Number: CTS PCF

Galvanized TurnbucklePart Number: CTS TRB

NEXT BACKMain Page

Page 16: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Troughing Belt Misalignment Detector

Troughing belt misalignment is detected by two upright arms, which are connected to an electrical switch by a glass reinforced polycarbonate coupling.

If the belt misaligns on either side to the extent that it could cause damage to the belt or conveyor structure, it contacts one of the upright arms. The arm tilts in the direction of the moving belt and activates the switch.

Adjustable mechanical trip delay on the switch coupling mechanism prevents false trips.

Switch structure is designed to minimize material build-up which could render the switch inoperable.

Belt protection units can be combined to meet your specific needs.

Enclosure: I.P. 66

Housing: High Impact Polycarbonate

Switch: Rated 16A/500V (2 normally open and 2 normally closed contacts)

Part Number: CTS 700 BL

Conveyor Belt Protection:Return Belt Misalignment Detector

Return belt misalignment is detected by two downcast arms, which are connected to an electrical switch by a glass reinforced polycarbonate coupling.

If the belt misaligns on either side to the extent that it could cause damage to the belt or conveyor structure, it contacts one of the downcast arms. The arm tilts in the direction of the moving belt and activates the switch.Adjustable mechanical trip delay on the switch coupling mechanism prevents false trips. Switch structure is designed to minimize material build-up which could render the switch inoperable. Belt protection units can be combined to meet your specific needs.

Enclosure: I.P. 66 Housing: High Impact Polycarbonate Switch: Rated 16A/500V(2 normally open and 2 normally closed contacts)

Part Number: CTS 700 RBL

NEXT BACKMain Page

Page 17: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Conveyor Belt Tear Detector

A tear to the wing section of the belt is detected by a profiled arm mounted below the belt, which is connected to an electrical switch by a glass reinforced polycarbonate coupling.

A torn piece of belt hanging at least 2 3/8" (60 mm) beneath the belt will strike the profiled arm, and activate the switch.

Part Number: CTS 700 BTEnclosure: I.P. 66

Housing: High Impact Polycarbonate

Switch: Rated 16A/500V (2 normally open and 2 normally closed contacts)

Conveyor Belt Protection:Conveyor Belt Tear and Rip Detector

Combines two types of protection on a single frame.

A tear in the belt's wing section or a rip in the belt's center section is detected by a profiled arm mounted below the belt, which is connected to an electrical switch by a glass reinforced polycarbonate coupling.

A torn piece of the belt's center or wing section that hangs at least 2 3/8" (60 mm) under the belt will strike the profiled arm mounted under the belt, activating the switch.

Adjustable mechanical trip delay on the switch coupling mechanism prevents false trips. Switch structure is designed to minimize material build-up which could render the switch inoperable. Belt protection units can be combined to meet your specific needs.

Part Number: CTS 700 BTR

Enclosure: I.P. 66

Housing: High Impact Polycarbonate

Switch: Rated 16A/500V (2 normally open and 2 normally closed contacts)

NEXT BACKMain Page

Page 18: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Conveyor Belt Speed Unit

Belt speed is monitored by a spring-loaded revolving roller mounted underneath the troughing belt. A sensor monitors pulses from the revolving roller.

The enclosure contains a programmable electronic motion detector that displays the speed of the belt in feet per minute. The unit receives a signal from the speed roller, which can be monitored in two modes:

Part Number: CTS 700 BSDStatic mode monitors for off-speed condition

Dynamic mode monitors for movement, acceleration, and operating speed

Adjustable mechanical trip delay on the switch coupling mechanism prevents false trips. Switch structure is designed to minimize material build-up which could render the switch inoperable. Belt protection units can be combined to meet your specific needs.

Enclosure: I.P. 66 Housing: High Impact Polycarbonate Power Requirements: 120 VAC Switch: One normally closed and one normally open contact

Conveyor Belt Protection:Belt Misalignment and Tear Detector

Troughing belt misalignment is detected by two upright arms, which are connected to an electrical switch by a glass reinforced polycarbonate coupling.

If the belt misaligns on either side to the extent that it could cause damage to the belt or conveyor structure, it contacts one of the upright arms. The arm tilts in the direction of the moving belt and activates the switch.

A tear to the wing section of the belt is detected by a profiled arm mounted below the belt, which is connected to an electrical switch by a glass reinforced polycarbonate coupling.

A torn piece of belt hanging at least 2 3/8" (60 mm) beneath the belt will strike the profiled arm, and activate the switch.

Part Number: CTS 700 BLTEnclosure: I.P. 66 Housing: High Impact Polycarbonate Switch: Rated 16A/500V(2 normally open and 2 normally closed contacts)

NEXT BACKMain Page

Page 19: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Belt Misalignment, Tear, and Speed Detector

Troughing Belt Misalignment Detection

Troughing belt misalignment is detected by two upright arms, which are connected to an electrical switch by a glass reinforced polycarbonate coupling.

If the belt misaligns on either side to the extent that it could cause damage to the belt or conveyor structure, it contacts one of the upright arms. The arm tilts in the direction of the moving belt and activates the switch.

Troughing Belt Tear Detection

A tear to the wing section of the belt is detected by a profiled arm mounted below the belt, which is connected to an electrical switch by a glass reinforced polycarbonate coupling.

A torn piece of belt hanging at least 2 3/8" (60 mm) beneath the belt will strike the profiled arm, and activate the switch.

Belt Underspeed/Slip Detection

Belt speed is monitored by a spring-loaded revolving roller mounted underneath the troughing belt. A sensor on the structure receives pulses from the revolving roller.

Part Number: CTS 700 BLTS

Conveyor Belt Protection:Doppler Conveyor Belt Speed Unit

Non-contact, high accuracy speed unit has no moving parts so it is maintenance free.

The Doppler Speed Unit uses the latest technology to provide a revolutionary method of monitoring conveyor speed. The unit is equipped with a 2-line LCD display with 4 push buttons. The push buttons are used to configure the unit, and belt

speed is displayed on the LCD with the belt is in motion. Part Number: CTS 7000 DSU

NEXT BACKMain Page

Page 20: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Infrared Conveyor Belt Rip Detector

Part Number: CTS 9000 IRRD

Network of infrared sensors detects material spilled through a rip in the conveyor belt.

The Infrared Rip Detector is an electronic device consisting of a network of infrared sensors mounted beneath the troughing belt. If a foreign object penetrates the belt, material will fall through the cut in the belt onto the detector's tray. As material builds up on the tray, the infrared beams are blocked and the conveyor is stopped. A "wash" cycle allows the unit to be cleaned without stopping the conveyor belt.

Conveyor Belt Protection:Ultrasonic Conveyor Belt Misalignment Detector

Ultrasonic beams detect misalignment with no moving parts.

The Ultrasonic Misalignment Detector has a profiled arm shaped in the same configuration as the troughed section of the belt. Two alignment sensors near its edge each emit a narrow ultrasonic beam towards the belt surface at predetermined

angles. The beams are reflected back to the sensors.

Belt misalignment in either direction causes the reflected signal to be outside the acceptable limit, and the detector will provide a visual indication that misalignment is occurring. If misalignment continues beyond a predefined time limit, the

detector will trip and must be manually reset. Part Number: CTS 7000 RF/BL

NEXT BACKMain Page

Page 21: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Conveyor Belt Protection:Motion Detector

Programmable electronic motion detector displays the speed of any rotating or moving object in meters per second, feet per second, or revolutions per minute (RPM).

An object's movement is detected by a proximity switch connected to the unit, in two different modes:

Static mode monitors for off-speed condition

Dynamic mode monitors for movement, acceleration, and operating speed

A two line LCD and four push buttons are used to set system mode, run speed, trip speed, movement time, acceleration time, and other settings.

Part Number: CTS 700 MD

Conveyor Belt Protection:Blocked Chute Detector

The blocked chute detector is a tilt switch mounted inside the chute to detect any restriction of material flow within a transfer point. Blockage which causes the switch to tilt more than 15° will activate the switch.

The switch consists of 3 normally closed mercury switches connected in series, mounted 120° from each other. A steel enclosure provides optimum protection.

Part Number: CTS 600 BCD

NEXT BACKMain Page

Page 22: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Engineering Capabilities

Our Electrical Controls Division can design, build, integrate and test a system customized for your needs, planned for the best cost efficiency and ease of operation.

As a company with many years of experience in the material handling industry, we understand the entire process rather than only the individual controls.

From 10 feet to 10 miles, we can provide the complete solution for your conveyor control needs.

Any level of service and components, literally from the pull cord switch to the SCADA screen.

Complete system pre-testing eliminates start-up delays. Because we provide both the field components and control units, we can completely test the entire system prior to shipment, eliminating delays due to incompatible components.

Head End Control Unit (HECU)

Conveyor Trip Switches with Pre-Start Warning Alarm

Conveyor Underspeed/Slip Detector(Connected direct to controller)

Sequence Roller(Connected to controller of upstream conveyors)

Pull Cable Pull Cable Carrier (Pigtail)

Blocked Chute Detector

Fusable Plug Bearing

Temperature Tension Limit Switches

Troughing Belt Misalignment Detector

Return Belt Misalignment Detector

Troughing Belt Tear Detector Return Belt Rip Detector

NEXT BACKMain Page

Page 23: Know whats wrong, anywhere on your conveyor line(s): 24hrs a day 7 days a week 365 days a year. A Simple Switch or Alarm will: Save Lives Prevent Costly

Phone: 800-940-4044Fax: 800-845-6787

Click below for more information:

www.directline-supply.comwww.directline-supply.com

Let us automate you!Questions? Comments?Call us or visit us online.