Kitchen ventilation technology
Ventilation towers
Ventilation components for cleanroom areas
2
Südluft SyStemtechniK in Plattling (BaVaria)
the company Südluft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
ceiling ventilation system . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-21
Overview of systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Sl-altiuS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Sl-crOniS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sl-Select . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sl-PlanO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Ventilation hoods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-31
Wall-mounted hoods . . . . . . . . . . . . . . . . . . . . . . . . . . 24
ceiling hoods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Product variations . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
equipment versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-41
Sl-thermO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
Sl-micrOmatic . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35
Sl-uV/uVh-cOntrOl . . . . . . . . . . . . . . . . . . . . . . .36-37
Sl-ecOcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-39
Sl-aKuStiK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Sl-injeKtiOn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
accessories / technical basic data . . . . . . . . . . . . . . . . . . 42-45
lighting types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-43
Separator types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Ventilation towers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46-57
Ventilation components for cleanroom areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-61
cOn
ten
tS
3
4
the name Südluft guarantees quality in the ventilation technology sector – and has done so for decades . Where sector-specific
innovation meets practical design know-how and compelling technology . the range of successfully completed projects and our
customer satisfaction highlights this spectacularly . as a reliable partner of builders, property developers and planners, we recognise
the demands of contemporary ventilation technology and meet them time and time again . With high-quality, energy-saving and
sustainable products, we meet the environmental concepts and forward-thinking business philosophy of Südluft .
intrOducing an innOVatiVe cOmPany
your projects are in good hands
– we are certified in accordance
with iSO 9001:2008
made in germany – frOm Planning and in-hOuSe
manufacturing tO On-Site aSSemBly .
Kitchen VentilatiOn technOlOgy (ceiling VentilatiOn / VentilatiOn hOOdS)at the forefront of this sector is the manufacture, supply and assembly of industrial ceiling ventilation systems
adapted to the individual structural conditions . Ventilation hoods for industrial kitchens are manufactured in
standard designs and as individual solutions .
air guidance SyStemSthis sector is defined by the “modular duct” . a patented, gas-tight duct system, which was specially developed for
exhaust air management in automotive paint shops and which meets the highest demands in impermeability,
resistance to corrosion, easy assembly and even visual appearance . as accessories for these systems, which are built
with complete engineering, the range includes pipework construction for hot gas lines and smaller steelwork and
complete assembly . clients are predominantly plant and mechanical engineering companies .
VentilatiOn tOWerS and cOmPOnentS fOr cleanrOOm areaSthis sector comprises external and exhaust air towers, particulate filters for cleanroom areas,
airlock systems for cleanrooms and laser, edging and welding operations .
Our BuSineSS fieldS
5
6
ceiling VentilatiOn SyStemScOmPlete SOlutiOnS fOr OPtimum Kitchen VentilatiOn . a ventilation system for industrial kitchens must satisfy several requirements: supply fresh air, save energy, guarantee sustainable
and fault-free operation, satisfy aesthetic standards, be expandable and upgradable .
Only those who have been able to gather decades of experience in the specific requirements of industrial kitchens and combine
this with innovative technology, possess a solid basis to deliver impressive results . and those who enjoy close proximity to clients
thanks to a strong distribution network can offer real solutions .
thus, Südluft provides complete solutions that are accurately tailored to the respective structural and usage conditions . through
components that have been tried and tested over many years such as aerosol separators, lighting systems, ceiling panel elements
and supply air outlets, Südluft lays the foundation for successful planning support and the full satisfaction of the respective ope-
rator, investor, engineers and architects .
from the analysis of spatial requirements to the planning,
consultation and selection of suitable modules, and finally the
assembly and configuration in the kitchen facilities, you receive
everything from one source and all “made in germany”!
SOPhiSticated technOlOgy, imPreSSiVe imPact . Südluft kitchen ceiling ventilation systems are individually designed and adapted to all requirements with the greatest care and
exceptional know-how . flexibility and attention to detail play a key role here .
Südluft offers the highest quality standards in closed ceiling systems, whereby greasy exhaust air is prevented from coming into
contact with the building structure . this eliminates the risks of hazardous bacterial growth on the building . the flush-mounted
lighting system under Sekurit safety glass was specially developed for use in kitchens . the iP55 protection class achieved for the
entire lamp installation box is practically unique .
careful Planning and
PrOceSSing fOr indiVidual
requirementS
7
8 9
StrOng PrOduct lineS . four different basic equipment lines are available . each one with individual advantages and in proven Südluft quality:
everything you need for extensive aeration and ventilation including flexible determining of the focal point above the cooker,
in active areas with trapezoid exhaust air ducts and in passive areas comprising flat panel ceilings, available with recessed
single lights, strip lights or downlights . the supply air is drawn in through displacement air outlets with plenum boxes or
optionally as excess pressure covers with perforated ceiling panels .
We present our four product lines below:
•Sl-altiuS
•Sl-crOniS
•Sl-Select
•Sl-PlanO
OVerVieW Of SyStemSceiling VentilatiOn SyStemS
8 9
humboldt university mensa-nord, Berlin
9Beach house,
nordwijk aan Zee (nl)
10 11
this system is manufactured from extruded aluminium profiles specially developed by Südluft . these are bolted, sealed and
condensation-proof . the ceiling can be delivered ral powder-coated or anodised .
ceiling VentilatiOn SyStemS Sl-altiuS
Vier jahreszeiten, hamburg Vier jahreszeiten, hamburg
1110 11
this ventilation ceiling impresses through high-quality 1 .4301 stainless steel with K240 duplo finish . the trapezoid exhaust air
ducts are firmly welded with a brushed surface . ideal for coping with high thermal or mechanical stress .
Sl-crOniS
ruhr university, Bochum daimler, mettingen
12 13
Sl-Select
individual product lines and versions are combined here . We meet your individual specifications . a mixture of materials, individual
colour schemes and the incorporation of extractor hoods with ceiling ventilation systems are possible .
ceiling VentilatiOn SyStemS
edeka, hamburg Brandauer, gerngross
1312 13
Sl-PlanO
in thiS caSe: flat iS gOOd . the Sl-PlanO boasts a homogeneous view from below . it is recessed into the ceiling with integrated flush-mounted exhaust
panels as required . all other functional elements are flush-mounted and create an appealing aesthetic .
BmW, leipzig enBW canteen, Stuttgart
14 BmW-Welt, munich
15Sportschloss, Velen
16 Scelta, Venlo (nl)
edeka, hamburg 17
18
convention hall, tashkent (uZ)
19
BmW-Welt, munichZf, Passau
20
21trumpf, ditzingen
trumpf, ditzingen
22
VentilatiOn hOOdSthe core business of Südluft SyStemtechniK has
always been ventilation hoods . What began as the
flagship product of a small family company more
than 40 years ago, was perfected by Südluft with
entrepreneurial vision . the technical maturity and
variety that can be specified for standard hoods is
impressive .
We construct ventilation hoods based on your
requests and ideas . We would be happy to realise
these in accordance with all conventional standards
and provisions .
rupert, Windorf
23
fresh air in the kitchen and excellent function of the
aerosol separator in the ventilation hood are core
requirements for kitchen aeration and ventilation .
Of course all Südluft products comply with the cur-
rent valid provisions in every respect, particularly Vdi
and din .
quality and VerSatility Say
it all
24 25
Wall-mounted hoods are ideal for capturing exhaust air above thermal kitchen appliances and counters .
this hood is manufactured in the following designs:
VentilatiOn hOOdS Wall-mOunted hOOdS
tyPe e-K
tyPe f-K
Single-row wall-mounted hoods in box design Single-row wall-mounted hoods in trapezoid design with bevelled front
Single-row wall-mounted hoods in elevated box design – ideal for small spaces or narrow installation points . this shape ensures optimal headroom for users .
Single-row wall-mounted hoods in elevated trapezoid design with bevelled front – ideal for small spaces or narrow mounting locations . this shape ensures optimal headroom for users .
tyPe e
tyPe f
2524 25
Whether freestanding stoves, double-row cooking stations, serving counters or cooking islands, Südluft provides individual ceiling hood
solutions – made to measure! the following hood types complete the Südluft range and set it apart from competitors:
ceiling hOOdS
tyPe h
Single-row ceiling hoods in slim trapezoid design with bevelled long edges
tyPe c
double-row ceiling hoods with V-shaped separator row in trapezoid design
double-row ceiling hoods with V-shaped separator row in box design
tyPe c-K
double-row ceiling hoods with edge suction on the long sides
tyPe c-K/gf
tyPe h-K
Single-row ceiling hoods in slim box design
tyPe d-K
double-row ceiling hoods in elevated box design – ideal for small spaces or narrow mounting locations . this shape ensures optimal headroom for users .
tyPe d
double-row ceiling hoods in elevated trapez-oid design – ideal for small spaces or narrow mounting locations . this shape ensures optimal headroom for users .
26 27
SOftlineelegant and hygienic
Südluft products look high-quality instantly and also
on closer inspection . you decide whether the ventilation
hood should form the focal point of the kitchen or blend
in with the entire space . the stainless steel surface exudes
quality . hood designs with softline edges are the cherry on
the cake . the rounded corners and edges set soft design
accents and increase the hygiene standard .
almost all hood models are available with softline edges .
With circumferential aerosol collecting channel on request .
easy cleaning, fewer deposits .
SOurce air hOOdthe all-rounder in hoods saves space and money! Ventila-
tion hoods with integrated supply air intake in the form of
front displacement air outlets . ideal as a compact compo-
nent, it creates a focal point, collects vapours above the
cooker and feeds low-draught and low-induction supply air
into the kitchen .
using a perforated front plate with 40 % free cross-section,
6 .0 mm hole spacing and 4 .0 mm hole diameter, the tem-
pered supply air flows evenly through an isolated pressure
chamber inside the hood in the kitchen area . compatible
with practically all hood types (excluding tyPe f-K, f, d-K, d
and cK/gf), this hood type serves as an all-rounder to suit
a wide range of applications .
VentilatiOn hOOdS PrOduct VariatiOnS
2726 27
injectiOn hoods with supportive flow technology are used to coun-
teract cross-flows and efficiently collect cooking vapours .
the injection hood is available as both a wall-mounted
hood and a ceiling hood . the pre-tempered fresh air is
blown into the isolated supply air pressure chamber via
diffuser plate and the supportive flow nozzles to stabilise
the thermal stream in the hood .
Supportive flow nozzles can be adjusted to the respective
air volume and create a strong stabilisation effect with 30 -
50 m3/h per linear metre of hood length .
inductiOn With this technical hood version, an induction volume flow
of max . 20 % of the entire volume is blown directly into the
hood . this enables enhanced extraction of the exhaust air
and improved collection . contrary to the injection prin-
ciple, the tempered supply air is not blown into the hood
storage space through nozzles but through adjustable
ventilation grates, which enable optimum fine tuning .
28
hood type e
hood type h – with optional touch panel
hood type c – with optional touch panel
Whether wall-mounted
or ceiling hood – the perfect model
from Südluft is tailored
to your requirements!
alWayS the Perfect
SOlutiOn!
Südluft canteen, Plattling 29
3030 ruhr university, Bochum
31
ruhr university, Bochum
32 33
WaSte-heat recOVery SaVeS energy . do you want to minimise your ventilation energy costs?
Sl-thermO enables reduced energy consumption (up to 30 %) compared with standard hoods . the heat exchanger is installed
precisely above the cooking equipment, where the exhaust air temperatures are highest . the cold fresh air is conducted and pre-
warmed in a flat tube heat exchanger in the cross-flow for the warm kitchen exhaust air . the reheater positioned behind it is only
activated in extreme cold to heat the air to the desired temperature . all with significantly lower energy consumption .
enormous reduction of heating and energy costs
Summer-winter changeover, automatic or manual
Practical conservation of resources and significant cost savings
equiPment VerSiOnS fOr ceiling VentilatiOn and hOOdS Sl-thermO
3332 33
Sl-thermO – a cOmPact SyStem integrated in the
hOOd and/Or ceiling fOr highly efficient heat recOVery .
thanks to the special design, this development is ideal for exhaust air that contains aerosols and solves the problem of a central
system . the distance of the flat tube in the heat exchanger is sufficient to avoid any blockage or severe contamination, so service
life and pressure drop are not negatively influenced . the clash of cold fresh air and hot exhaust air generates condensation on the
surface of the exchanger pipe in the hood interior . this condensation automatically “rinses” the grease particles from the heat
exchanger and may run down the back to the aerosol separator in the condensation collection channel and drain off from here .
We therefore refer to a self-cleaning action, as the heat exchanger keeps itself clean without additional devices .
an output as regards heat recovery efficiency and design of the reheater and/or heating output
can be calculated on a case-by-case basis .
34 3534
BiOlOgical SecOndary treatment Of aerOSOlateS in accOrdance With din 18869-7 – fOr ceiling and hOOd .By this method, your ventilation system is automatically kept free of aerosolate
deposits in a thorough, convenient, biodegradable and energy-efficient way .
Sl-micrOmatic uses the properties of natural enzymes to biodegrade aero-
solate and fat particles in the ventilation hood . Spray nozzles in the storage
space opposite the aerosol separators generate a fine spray mist . this mist
mixes with the thermal airflow of the kitchen exhaust air . this evenly distributes
the mist throughout the entire system and wets the surface of the exhaust air
components . this biofilm dissolves aerosol deposits and prevents the forma-
tion of new deposits . the cultures break down the molecular chains of the
aerosols . this generates water and carbon dioxide, which is simply removed
with the exhaust air flow . the spraying process repeats automatically . its
frequency can be individually adapted to the kitchen operations .
Sl-micrOmaticequiPment VerSiOnS fOr ceiling VentilatiOn and hOOdS
34 35
Secondary treatment of aerosolates using 100 % biodegradable enzymes
convenient programne automation for optimised spraying frequency
reduced workload: cleaning cycles are extended several times over . laborious, manual cleaning is obsolete .
aerosol post-treatment system pursuant to din 18869 Part 7
35
Sl-micrOmatic is tailor-made to your ceiling ventilation system and also for extractor hoods, and can of course be retrofitted . it goes
without saying that all materials used with the Sl-micrOmatic comply with the current strict legal requirements . We would be happy
to advise you on the most suitable Sl-micrOmatic solution for your individual needs .
enzymes break down any layers of grease Biofilm formation to repel greasy deposits
certified Safety fOr indiVidual requirementS
air flOW
greaSe layer
hOOd/metal Sheet
air flOW
BiOfilm fOrmatiOn
hOOd/metal Sheet
36 37
With uV light and OZOne . fOr ceiling and hOOd .tried-and-tested technology based on ultraviolet (c) light and ozone supplements the separator function of conventional systems
and eliminates noise . new accumulation of soot is effectively prevented . the Sl-uV-cOntrOl works with special uV lamps, a paten-
ted safety device and a monitoring controller with individual lamp testing . the special uV lamps are mounted behind the aerosol
separator .
during the cleaning process the odorous and greasy exhaust air is absorbed by the kitchen ventilation system and guided through
the special uV lamps . a photolytic oxidation process takes place whereby the organic substances in the exhaust air (e . g . grease) are
destroyed . grease loads and noise emissions are significantly reduced – by up to 95 %! the final products are oxygen, carbon dioxide,
water and dust-like, 100 % biodegradable by-products, which are removed by the exhaust air system .
almost 100 % absorption can be achieved
increased service life of ventilation through open ducts
retrofitting into existing systems possible
furthermOre: the Kitchen ceiling VentilatiOn
remainS clean and dry Within the range Of the uV lamPS . the lamPS SimPly need tO Be checKed and
WiPed if neceSSary during regular cleaning .
Sl-uV/uVh-cOntrOlequiPment VerSiOnS fOr ceiling VentilatiOn and hOOdS
36 37
cleVer liKe nature the system is based on the impact of short-term uV radiation (photolysis)
and the chemical reaction of the ozone (O3) produced by the atmospheric oxy-
gen (O2) with the organic particles (oxidation) . Ozone is an extremely reactive
and unstable form of oxygen that can oxidise organic substances in the air
e .g . grease . at the same time bacteria, germs, spores and viruses are killed
(ozone disinfects 100-times more quickly than hypochlorite) .
truSt iS gOOd – cOntrOl iS Better for this reason Südluft leaves nothing to chance, including this system: all
system components are monitored via a modern BuS system in conjunction
with a touchscreen . at any time the control unit can supply all relevant infor-
mation on the operating status of the system e .g . filter monitoring and func-
tion of the safety locks, status of the uV lamps, operating hour meter or fault
monitoring in the exhaust air duct system . the tool also immediately reports
any faults, thus ensuring perfect functionality .
37
38 39
SenSitiVely cOntrOlled . fOr ceiling and hOOd .the energy costs for heating fresh air account for a large portion of overall operating costs for industrial kitchens . the “intuitive”
Sl-ecOcontrol allows energy savings of up to 80 % . it also creates a pleasant working environment . Sl-ecOcontrol air conditioning
ensures the perfectly balanced supply of fresh air . heating this cold air is exactly what causes high energy costs and expenditure .
Photoelectronic sensors continuously detect the volume of rising vapours . the speed control is regulated based on these values .
the ventilation adjusts automatically to the current requirements at any time . it is also possible to activate zone valves and volume
flow controllers . the air is quickly and effectively exchanged in brief peak loads . Otherwise the system runs on a pilot flame .
cost minimisation guaranteed .
Precise sensory control for high energy efficiency
high operating comfort through automation
Pleasant indoor climate through “intermittent airing effect“
Sl-ecOcontrol
light barrier (invisible to the naked eye)
equiPment VerSiOnS fOr ceiling VentilatiOn and hOOdS
38 39edeka, hamburg 39
40
a ceiling ensures peace and quiet – high noise levels cause additional stress for employees . this means increased risk of accident,
dissatisfaction and often illness . a good working climate in industrial kitchens therefore requires corresponding sound insulation .
Südluft developed Sl-aKuStiK for this very reason: a ceiling with exceptional sound-insulation properties, as certified by the
fraunhofer institute . the insulation is also hygienically sound and classified as “hardly flammable” .
highly efficient sound reduction and absorption
noticeably more comfortable soundscape
available in various colours and tailored to individual requirements
can also be retrofitted in existing panel ceilings
dimensionally-stable, hygienic, robust, light
Sl-aKuStiKequiPment VerSiOnS fOr ceiling VentilatiOn SyStemS
16
00
20
00
25
00
31
50
40
00
50
00
12
5
10
0
16
52
00
25
0
31
54
00
50
06
30
80
0
10
00
12
50
Abs
orpt
ion
coef
fici
ent
Sound absorption in accordance with DIN EN 20 354
Thickness in mm
3040
6050
1.2
1.0
0.8
0.6
0.4
0.2
Note: The sound reduction index ranges from 10 to 16 dB depending on the strength of the material.
Frequency in Hz
4141
Sl-injeKtiOn
cross-flows, spread of smells, poor exhaust air collection, narrow spaces?
Südluft offers the solution to these problems with its supportive flow
elements in the Sl-injeKtiOnStechniK . exhaust air vapours and steam
are extracted with the exhaust air through vertical and horizontal air inlet
nozzles, which are connected to the fresh air supply via a special construc-
tion . these also allow enhanced separation through a constant and even
separator inflow .
furthermore, this technology enlarges the collection storage space, thus
increasing efficiency whilst reducing the exhaust air requirement . the total
supply air requirement is approx . 30 - 35 m3/linear metre, but max . 10 % of
the supply air volume . the required inlet pressure should be 50 Pa . Small
booster fans supply the necessary compression .
�
������������������������������������������������������������������������������������������
�������
�����������������������������������
�������������������������������
����� ������������ ������
�����
�������� ���� ����� ����
�������
����������������
�������������������������������������������������������
��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
���
���
�
������������������������������������������������������������������������������������������������������������������������������������
���������������������������������������������������������������������������������
��������������������������
�����������������
���
���
����������
�
�
�
����������
�����������
�
��������������
������������
���������������������������
����������
����������������
�
��
��������������������������������������������
5°
�
�
����
����
����
����
����
����
����
����
��������
����
����
����
���
����
����
����
����
����
����
����
����
����
����
����
����
����
���
����
����
����
����
����
������
������
������
������
����
���
����
����
����
����
����
����
����
����
����
����
����
����
����
���
����
����
����
����
����
������
����
����
����
����
���
�
������������������������������������������������������������������������������������������������������������������������������������������
������������������������������������������������������������������������������������������
��������������������������
����������
��������������
����������
�������� �����
�������
���������
������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
�������
���������
�������
�����
��������
�����
���� ����
��������������������
����������
�������������������������������������������������������������������������������
���
����
���������������������������
���
���
�
����������
�
�����������������
� �����������
�������������
������������
����������
�
�
�
���������
�
������������������������������������������
� ���������
2020
�������������������� ���������������������������������������� ����������������������
�������
�����������������������������������
�������������������������������
����� ������������ ������
�����
�������� ���� ����� ����
�������
����������������
�����������������������������������������������������
��������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
���
���
�
������������ ������������������������������������������ ������������������������������������������ ���������������������������������
��������������������������
�����������������
� ��
���
����������
�
�
�
����������
�����������
�
� �������������
������������
���������������������������
�����������������
��
������������������������������������������
85°
5°
42
acceSSOrieS / technical BaSic data ceiling VentilatiOn and hOOdS receSSed lamPS With led
led tuBeS230 V
light colour 5000 K
eSg ornament 504
dimmable: optional
Protection class: iP55
tube length Output luminous flux
600 mm 2 x 10 W 2300 lm
1200 mm 2 x 18 W 4200 lm
1500 mm 2 x 27 W 6100 lm
information per lamp (double-headed)
led circuit BOard205 - 264 V ac (50/60 hz) / 205 - 380 V dc
light colour 5000 K
eSg ornament 504
dimmable: yes
Protection class: iP55
lamp length Output luminous flux
600 mm 16 W 2056 lm
1200 mm 32 W 4112 lm
1500 mm 40 W 5140 lm
information per lamp
led dOWnlight230 V
light colour 2700 K, 4000 K
example a: swivelling, aluminium/iP44
example B: fixed, stainless steel/iP65
design diameter Output luminous flux
a 90 mm 4 W 255 lm
B 85 mm 4 W 250 lm
a B
43
receSSed lamPS - StandardreceSSed lamPS t5 Single-headed230 V
light colour 4000 K
eSg ornament 504
dimmable: optional
Protection class: aluminium iP55 /
stainless steel iP65
tube length Output luminous flux
600 mm 1 x 14 W 1200 lm
1200 mm 1 x 28 W 2900 lm
1500 mm 1 x 49 W 4300 lm
ceiling SPOtS 230 V
light colour 4000 K
clear glass
dimmable: optional
Protection class: aluminium iP55 /
stainless steel iP65
diameter Output luminous flux
220 mm 2 x 26 W 3600 lm
receSSed lamPS t5 dOuBle-headed230 V
light colour 4000 K
eSg ornament 504
dimmable: optional
Protection class: aluminium iP55 /
stainless steel iP65
tube length Output luminous flux
600 mm 2 x 14 W 2400 lm
1200 mm 2 x 28 W 5800 lm
1500 mm 2 x 49 W 8600 lm
information per lamp
44 4544
SeParatOr tyPeS
flameproof pursuant to ul 1046*
examination of separation characteristics according to Vdi 2052 / din 18869-5
examination of acoustic characteristics
Structural design according to din 18869-1 / 18869-2
flameproof pursuant to din 18869-5
flameproof pursuant to ul 1046*
examination of separation characteristics according to Vdi 2052 / din 18869-5
examination of acoustic characteristics
Structural design according to din 18869-1 / 18869-2
flameproof pursuant to din 18869-5
flameproof pursuant to ul 1046
examination of separation characteristics according to Vdi 2052
examination of acoustic characteristics
Structural design according to din 18869-1 / 18869-2
* according to requirement with same technical data
dimensionsl x W in mm
Pressure drop in Pa
Volume flow at 0 .7 m/s inflow velocity
exhaust air volume in m3/hSeparator noise in
dB(a)
500 x 500 53 600 54
500 x 350 53 450 54
500 x 250 53 300 54
500 x 200 53 250 54
WV-r - flOW SeParatOr - up to 94 % separation efficiency
dimensionsl x W in mm
Pressure drop in Pa
Volume flow at 0 .7 m/s inflow velocity
exhaust air volume in m3/hSeparator noise in
dB(a)
500 x 500 72 600 55
500 x 350 72 450 55
500 x 250 72 300 55
500 x 200 72 250 55
WV-r - cOmBinatiOn SeParatOr - up to 98 % separation efficiency
dimensionsl x W in mm
Pressure drop in Pa
Volume flow at 0 .7 m/s inflow velocity
exhaust air volume in m3/hSeparator noise in
dB(a)
500 x 500 80 600 55
500 x 350 80 450 55
500 x 250 80 300 55
500 x 200 80 250 55
WV-r/WV- duPlO SeParatOr - up to 98 % separation efficiency
acceSSOrieS / technical BaSic data ceiling VentilatiOn and hOOdS
4544 45
material
V2a chrOmium nicKel Steel 1 .4301 With K 240 duPlO finiSh this material is particularly corrosion resistant to air humidity, water and most acids and alkaline solutions .
Optimum material properties eliminate contamination through negative hygiene factors such as germs,
bacteria, viruses and fungus .
anOdiSed and POWder-cOated aluminiumanodic oxidised (anodised) aluminium has a silver-white sheen . the corrosion resistance is based on a thick, hard,
connected and transparent oxide layer with just a few molecule layers, which forms on freshly scarified aluminium
within seconds in open air and under water . this resistance to acids and alkaline solutions and corrosion resistance
does not endanger food hygiene .
Südluft OfferS the fOllOWing cOlOur SchemeS aS Standard:
ceiling in aluminium deSign
- anodised
- ral 9010 powder-coated (standard colours)
ceiling in StainleSS Steel deSign
- 1 .4301 stainless steel with K 240 duplo finish
all non-standard colours are available on customer request .
a longer lead time must be taken into account .
46
VentilatiOn tOWerSSüdluft ventilation towers prove that functionality and imposing
design can co-exist . Sl-Sfera introduces a new dimension in building
planning .
Ventilation towers harmoniously integrated into the overall architec-
ture – or as an accentuating, independent “artwork” . a shining enhan-
cement of design possibilities in the truest sense of the word . the use
of geothermal power is interesting from an energy perspective .
dmg-europe, Klaus (a) 47
48 4948
imPreSSiVe deSign elementS, imPreSSiVe functiOnality . Whether ascending external walls, enthroned on the roof or an eye-catching feature on company
premises, inside and outside, with Sl-Sfera you can create unmistakeable architecture and land-
marks visible for miles around . the inner workings of the Sl-Sfera towers impress through their
technology, low-maintenance and longevity . Sl-Sfera: Ventilation towers that aren’t too good to
be true!
Sl-Sfera has all the hallmarks of a good external and exhaust air tower . including more than 30
years’ product experience, tried-and-tested materials and excellent manufacturing quality .
available in stainless steel or normal steel, with or without lamellae . the technical design of the
ventilation towers guarantees excellent ventilation performance without disruptive noise .
Verifiable statistics pursuant to din are available for all requested load scenarios .
design, functionality and quality from Südluft – an all-round success!
Sl-Sfera - the VentilatiOn tOWer VentilatiOn tOWerS
48 49eurospar, Bludenz (a) 49
50 51lSe, graz (a) Office building, Berlin50
VentilatiOn tOWerS
5150 51
mOunting VariantS:
technical BaSic data
Standard mounting with
hV anchor pegs screwed into
concrete ceiling or concrete
foundations
Standard mounting with
concrete-encased anchor cage
in 1 .4301 or galvanised S235
Sealing VariantS fOr VentilatiOn tOWerS - mOunting On cOncrete ceiling
VentilatiOn tOWerS
52
external and exhaust air towers are construction products according to Buildings rules list “a” Part 1 2012/1 no . 4 .10 .2 .
the “technical rules” stipulated therein must comply with the applicable regional building regulations .
Planning, dimensioning, design and manufacture are performed exclusively using eurocodes .
they are only marketable and may only be used if they are furnished with a ce mark of the manufacturer pursuant
to din en 1090 .
Sl-Sfera ventilation towers are may only be used for their intended purpose i .e . con-
ducting fresh air and uncontaminated exhaust air without increased temperature or
extracting smoke with increased temperature .
Datei: S.52 CE-Konformitätskennzeichnung SL_SFERA 1.4307 140627.docDruck: 06.08.2014
Südluft Systemtechnik GmbH & Co. KG, Plattling
14
2451-CPR-EN1090-2013.0304.001
EN 1090-1
SL-SFERA ventiliation chimney
Südluft Systemtechnik GmbH & Co. KG, Plattling,
Robert-Bosch-Straße 6
Geometric tolerances: EN 1090-2 / Class 1
Weldability: 1.4307 in accordance with EN 10088-2
Fire behaviour: Class A1 rated material
Release of Cadmium: KLF
Release of radioactive radiation: KLF
Durability: Surface preparation in accordance with
EN1090-2, preparation grade P1
Load capacity: Measurement in accordance
with DIN EN 1993-3-2 and DIN EN 1991-1
Manufacturing: In accordance with component
specifications and EN 1090-2, execution class EXC 3
2451
regional hospital, Bregrenz (a) Police barracks, Waldeck 53
54
triple sports hall, altötting
red Bull, fuschl (a)
lindner, Wals (a) eurospar, Bludenz (a) 55
VentilatiOn tOWerS
56
VariantS
tower roof type t15 - 45° bevel
tower roof type t2
tower open at top (for exhaust air) protected by removable bird protection screen . lamellae head is omitted or performed “blind” (optic)
tower roof type t3 tapered
lamellae head l/45°, tower pipe lamellaeprotruding h = 50 - 150 mm
Static load-bearing tower pipe available in welded or screwed design
height-dependent flange division
rain cap (optional)
Water inhibitor with combina-tion of vertical connector and exhaust air (open at top)
condensation base with combi-nation of lateral connector and exhaust air
available with lateral connector and square connector
mounting variants:- with mounting flange- with din flange + anchor cage
trim ring for sealing film (optional)
inspection doors
lamellae head lB/45°/B tower pipe lamel-lae flush with vertical cover
lamellae head lB/45° tower tub lamellae h = 50 - 150 mm
57
geOthermal energy tOWerS
intaKe tOWer fOr geOthermal energy Specially designed for fresh air intake of geothermal systems, with highest ventilation and
acoustic requirements . Variable connection possibilities to all geothermal systems .
acceSSOrieS - connector junction for ht pipes
- replacement filter mat, filter class g3
- Velcro strip to mount filter
- hVZ anchor for tower mounting
- Stainless steel care products
laser-cut filter basket for holding the filter
mat . this is mounted using clamping rings or
Velcro strips . Below with sealing strip – thus
no suction of unfiltered fresh air possible .
name af lam . filter ring∆P
filter∆P
total
eWt-260 0 .17 m2 1 .23 m/s 6 m/s 30 50
eWt-330 0 .27 m2 1 .49 m/s 4 m/s 35 65
eWt-415 0 .36 m2 1 .8 m/s 5 m/s 35 65
eWt-520 0 .47 m2 1 .73 m/s 4 m/s 35 65
5858
VentilatiOn cOmPOnentSfOr cleanrOOm areaSthe air iS clean . fOr Sure!clean air as a crucial success factor . Our air is interspersed with fine dirt and dust particles . in many sectors this needs no further
mention, provided it does not have a negative impact on quality of life . it’s a different situation in areas where clean air is crucial to
the desired results . clean air can be vital particularly in the medical sector . Operations that take place in contaminated air consti-
tute an enormous health risk . When it comes to the success of surgery or recovery of patients, operating theatres, clinics and hospi-
tals depend on reliable filter technology . the same applies for modern production facilities in the pharmaceutical, microelectronic
and semi-conductor industries . clean rooms are prerequisite for the manufacture of sensitive products .
59
VentilatiOn cOmPOnentS Particulate filterS
the air is interspersed with fine dirt and dust partic-
les . in some sectors this poses significant risks to the
production quality or can influence quality of life . Sl
particulate filters in Südluft ventilation shafts provi-
de remedy here .
mounting depth l = variable 40 - 120 mm, dimension c = 20 mm,
indicated air flow-rate refers to 2 .5 m/s inflow velocity in mounting dimension with
max . 25 Pa pressure drop in clean state .
SelectiOn taBle - nOminal air flOW VOlume
the robust stainless steel frames of the particulate
filter are worked from one piece and backed with a
tight wire mesh pursuant to din iSO 4783 . mesh size
0 .5 x 0 .32 mm . the mounting frame is secured by solid
stainless steel knurled screws (20 mm border, plus 10
mm support) . Sl particular filters meet the require-
ments of din 1946, Part 4 .
Höhe (Maß B)in mm 225 325 425 525 625 725
125 58 m³/h 98 m³/h 140 m³/h 180 m³/h 220 m³/h 262 m³/h225 190 m³/h 325 m³/h 450 m³/h 580 m³/h 705 m³/h 838 m³/h325 325 m³/h 540 m³/h 760 m³/h 980 m³/h 1200 m³/h 1430 m³/h425 450 m³/h 760 m³/h 1075 m³/h 1380 m³/h 1700 m³/h 2005 m³/h525 580 m³/h 980 m³/h 1380 m³/h 1780 m³/h 2180 m³/h 2885 m³/h625 705 m³/h 1200 m³/h 1700 m³/h 2180 m³/h 2670 m³/h 3164 m³/h725 838 m³/h 1430 m³/h 2005 m³/h 2885 m³/h 3164 m³/h 3745 m³/h825 975 m³/h 1645 m³/h 2315 m³/h 2986 m³/h 3655 m³/h 4325 m³/h
Einbautiefe L = variabel von 40 - 120 mm Maß C = 20 mm
Breite (Maß A) in mm
Datenblatt für Flusenabscheider Type: SL-OP-FFS-K
Auswahltabelle - Nennluftvolumenströme
Angegebener Luftvolumenstrom bezieht sich auf 2,5 m/s Anströmgeschwindigkeit im Anschlußmaß, mit max. 25 Pa Druckverlust in gereinigtenZustand.
in Operationsräumen, Kliniken und Reinraumproduktionen.Flusenfilter der Serie FFS sorgen für die Abscheidung von Textilfasern
gh 29.12.2010J:\Flusenfilter\Flusenfilter_Datenblatt_Leistungstabelle.Type SL-OP-FFS-K.xls
height (dimen-sion B) in mm
Width (dimension a) in mm
225 325 425 525 625 725
125 58 m3/h 98 m3/h 140 m3/h 180 m3/h 220 m3/h 262 m3/h
225 190 m3/h 325 m3/h 450 m3/h 580 m3/h 705 m3/h 838 m3/h
325 325 m3/h 540 m3/h 760 m3/h 980 m3/h 1200 m3/h 1430 m3/h
425 450 m3/h 760 m3/h 1075 m3/h 1380 m3/h 1700 m3/h 2005 m3/h
525 580 m3/h 980 m3/h 1380 m3/h 1780 m3/h 2180 m3/h 2885 m3/h
625 705 m3/h 1200 m3/h 1700 m3/h 2180 m3/h 2670 m3/h 3164 m3/h
725 838 m3/h 1430 m3/h 2005 m3/h 2885 m3/h 3164 m3/h 3745 m3/h
825 975 m3/h 1645 m3/h 2315 m3/h 2986 m3/h 3655 m3/h 4325 m3/h
Höhe (Maß B)in mm 225 325 425 525 625 725
125 58 m³/h 98 m³/h 140 m³/h 180 m³/h 220 m³/h 262 m³/h225 190 m³/h 325 m³/h 450 m³/h 580 m³/h 705 m³/h 838 m³/h325 325 m³/h 540 m³/h 760 m³/h 980 m³/h 1200 m³/h 1430 m³/h425 450 m³/h 760 m³/h 1075 m³/h 1380 m³/h 1700 m³/h 2005 m³/h525 580 m³/h 980 m³/h 1380 m³/h 1780 m³/h 2180 m³/h 2885 m³/h625 705 m³/h 1200 m³/h 1700 m³/h 2180 m³/h 2670 m³/h 3164 m³/h725 838 m³/h 1430 m³/h 2005 m³/h 2885 m³/h 3164 m³/h 3745 m³/h825 975 m³/h 1645 m³/h 2315 m³/h 2986 m³/h 3655 m³/h 4325 m³/h
Einbautiefe L = variabel von 40 - 120 mm Maß C = 20 mm
Breite (Maß A) in mm
Datenblatt für Flusenabscheider Type: SL-OP-FFS-K
Auswahltabelle - Nennluftvolumenströme
Angegebener Luftvolumenstrom bezieht sich auf 2,5 m/s Anströmgeschwindigkeit im Anschlußmaß, mit max. 25 Pa Druckverlust in gereinigtenZustand.
in Operationsräumen, Kliniken und Reinraumproduktionen.Flusenfilter der Serie FFS sorgen für die Abscheidung von Textilfasern
gh 29.12.2010J:\Flusenfilter\Flusenfilter_Datenblatt_Leistungstabelle.Type SL-OP-FFS-K.xls
Particulate screen 1 .0 mm
V2a with wire mesh
60 6160
VentilatiOn cOmPOnentS Particulate Shaft / Particulate Barrier
an operation door with stainless steel hinges and turn bolt is located on the
front of the visible stainless steel suction duct with brushed, ground welded
seams . this allows simple cleaning of the fully-accessible interior . the duct is
fitted with two particulate filters: the lower mounted by bending, the upper
with mounting flange . the standard sheet thickness is 1 .0 - 1 .5 mm . Various
mounting versions are available for tiled or plaster walls .
the system can be individually adapted to the conditions of each room .
With Südluft your requirements and requests are in the best hands .
60 61
Sl Particulate filterS: Pure quality!
highest quality materials and workmanship
of all components
for efficient cleaning action today and
tomorrow
top functionality, easy to clean
also compatible with existing systems
Südluft quality and Südluft expertise:
an unbeatable combination!
61
62
yOur reliaBle,
innOVatiVe
Partner fOr
VentilatiOn
technOlOgy
PrePare tO Be imPreSSed By Our SerViceS!
VentilatiOn cOmPOnentS fOr cleanrOOm areaS
VentilatiOn tOWerS
Kitchen VentilatiOn technOlOgy(ceiling ventilation, ventilation hoods)
63
Südluft SyStemtechniK gmBh & cO . Kg
robert-Bosch-Straße 6 · 94447 Plattling · germany
telephone: +49 99 31/91 79 - 0 · fax: +49 99 31/91 79 -70
info@suedluft .de · www .suedluft .de
ww
w.c
reat
ivpa
rtne
r.com
· 03
/17
PlattlingStadtplatz
DirectionPassau
DirectionPassau
DirectionRegensburg
DirectionRegensburg
DirectionMünchen
Globus
Robert-Bosch-
Straße 6
Deggendorf
A92
B8
B8
A3
A3
Exit atPlattling Nord
Deggendorf motorway interchange
Exit atPlattling West