1
KINGFISHER LAKE WATER TREATMENT PLANT KAL provided engineering services to design the Kingfisher Lake Water Treatment Plant. The facility utilizes a dual train conventional water treatment system with full redundancy. The maximum design flow for each water treatment train is 4.65 litres/sec (402 m 3 /day). Each treatment train produces safe drinking water meeting O.Reg 170/03 at all possible flow rates equal to and less than 4.65 litres/sec. The scope of work for the water treatment plant incorporates the following building characteristics: 460 m 2 building Two conventional filtration units Concrete below grade reservoirs High lift pumping system Chemical feed system SCADA system Online instrumentation for continuous monitoring. Truck haul fill station Washroom and shower facilities. Work Room Emergency backup generator Various other associated works. Client Kingfisher Lake First Nation Services Pre-Design MOE Approval CEA Approval Detailed Design Tendering Contract Administration On-Site Inspection Reference Mr. Aaron Swansburg 807 623-3534 Year 2009 PROJECT EXPERIENCE

Kingfisher Lake WTP Lake WTP.pdf · 2015. 10. 14. · KINGFISHER LAKE WATER TREATMENT PLANT KAL provided engineering services to design the Kingfisher Lake Water Treatment Plant

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Kingfisher Lake WTP Lake WTP.pdf · 2015. 10. 14. · KINGFISHER LAKE WATER TREATMENT PLANT KAL provided engineering services to design the Kingfisher Lake Water Treatment Plant

KINGFISHER LAKE WATER TREATMENT PLANT

KAL provided engineering services to design the Kingfisher Lake Water Treatment Plant.  The facility utilizes a dual train conventional water treatment system with full redundancy.  The maximum design flow for each water treatment train is 4.65 litres/sec (402 m3/day).  Each treatment train produces safe drinking water meeting O.Reg 170/03 at all possible flow rates equal to and less than 4.65 litres/sec.  

The scope of work for the water treatment plant incorporates the following building characteristics:  

460 m2 building  

Two conventional filtration units 

Concrete below grade reservoirs 

High lift pumping system 

Chemical feed system 

SCADA system 

On‐line instrumentation for continuous monitoring. 

Truck haul fill station 

Washroom and shower facilities. 

Work Room 

Emergency back‐up generator 

Various other associated works. 

 

Client Kingfisher Lake First Nation

Services Pre-Design

MOE Approval CEA Approval

Detailed Design Tendering

Contract Administration On-Site Inspection

Reference Mr. Aaron Swansburg

807 623-3534

Year 2009