53
Key Value SSD Explained – Concept, Device, System, and Standard 09/14/2017 Yang Seok Ki Director of Memory Solutions Lab Samsung Semiconductor Inc.

Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

  • Upload
    vodieu

  • View
    228

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD Explained – Concept, Device, System, and Standard

09/14/2017Yang Seok Ki

Director of Memory Solutions LabSamsung Semiconductor Inc.

Page 2: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Disclaimer

2

This presentation and/or accompanying oral statements by Samsung representatives collectively, the “Presentation”) is intended to provide information concerning the SSD and memory industry and Samsung Electronics Co., Ltd. and certain affiliates (collectively, “Samsung”). While Samsung strives to provide information that is accurate and up-to-date, this Presentation may nonetheless contain inaccuracies or omissions. As a consequence, Samsung does not in any way guarantee the accuracy or completeness of the information provided in this Presentation.

This Presentation may include forward-looking statements, including, but not limited to, statements about any matter that is not a historical fact; statements regarding Samsung’s intentions, beliefs or current expectations concerning, among other things, market prospects, technological developments, growth, strategies, and the industry in which Samsung operates; and statements regarding products or features that are still in development. By their nature, forward-looking statements involve risks and uncertainties, because they relate to events and depend on circumstances that may or may not occur in the future. Samsung cautions you that forward looking statements are not guarantees of future performance and that the actual developments of Samsung, the market, or industry in which Samsung operates may differ materially from those made or suggested by the forward-looking statements in this Presentation. In addition, even if such forward-looking statements are shown to be accurate, those developments may not be indicative of developments in future periods..

Page 3: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Agenda• Cloud: A New Era• Scalability: A New Challenge• Key Value SSD: A New Technology

– Samsung Key Value SSD

• Ecosystem• Use Case and Performance Studies• Q&A

Page 4: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Agenda• Background• Concept• Key Value SSD• Ecosystem• Use Case and Performance Studies• Standards• Q&A

Page 5: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Cloud: A New Era & Challenges

Page 6: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

What happens in an internet minute?

6

1.5X

1.3X

1.3X

1.3X

Page 7: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

BC/AD in IT

6

Source: Human Computer Interaction % Knowledge Discovery

Page 8: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Challenges in Cloud Era

Scalable TCO

Capacity

Throughput

Latency

Power

Page 9: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Block: Parking Lot/Structure• A driver (host) is responsible for parking (data management)

9

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

P

Page 10: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Object: Valet Parking• A parking facility (storage) is responsible for parking (data

management)

10

“music”

“photo”

“zip file”

“document”

Page 11: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD: New Scalable Technology

Page 12: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Everything is object!

12

OSD Object Storage

ID Attributes User Data

KV Storage

Key Value

Page 13: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value Stores are Common in Systems at Scale

Page 14: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value in Systems at Scale: Twitter Timeline Service

14

Write API

Fanout

twemproxy

Followers

Key Value Store

Page 15: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Idea

Block Device Driver

Block Device

TX/s WAF, RAF, Latency

15

Host S/W

Traditional KV Store KV Stacks

Key Value Store is everywhere!

Thin KV Library

KV Device Driver

KV Device

KV

Page 16: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Samsung KV-PM983 Prototype

16

NGSFF KV SSD

Form factor: NGSFF/U.2Capacity: 1-16TBInterface: NVMe PCIe Gen.3

Page 17: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Physical Location / Offset

Index

User/Device Hash Key

NAND Page (32KB)

Lookup / Check hash collision

< NAND >

Read/Write User Data

Key Size Range ? Value Size Range ?

Key Value I/F Command

Key Value SSD device driver

Value Size

Meta data Key Value

Key Size

Get (key) / Put (Key, Value)

KV SSD Design Overview• Key/Value Range

– Key : 4~255B– Value : 64B~2GB (32B granularity)– The large value is stored into multiple NAND pages

Storage Server Key Value SSD

Page 18: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD is a Scalable Solution with Better TCO

18

• Performance• Capability

KV SSD

• Capacity• Performance

Scale-Up• CPU• Server

Scale-In

• TCO• Power

Scale-Down• Capacity• Performance

Scale-Out

TCO($)

Page 19: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV SSD Ecosystem

Page 20: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Ecosystem in Block and KV Device Era

BlockSSD

KVSSD

Page 21: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV SSD Ecosystem

Key Value SSD

Standard

Product

ApplicationsSDK

Partners

21

Page 22: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV SSD Ecosystem

Key Value SSD

Standard

Product

ApplicationsSDK

Partners

22

Page 23: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Applications for KV SSD

23

Distributed DB Object Storage SystemNoSQL DB

KV Device

KV Stacks

OSD

API

KV Adapter

KV Device

KV Stacks

API

KV Adapter

KV Device

KV Stacks

API

Storage EngineStorage Engine

Swift API

Page 24: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV SSD Ecosystem

Key Value SSD

Standard

Product

ApplicationsSDK

Partners

24

Page 25: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SW Stacks• SSD with native key value interface through hardware software co-design

Datacenter S/W Infra

Storage Plugin Interface

Block Interface

POSIX API

Key Value API

S/W Key Value Store

Key Value Glue Logic

File System

Block Device Driver

Index Log

JournalBlock Map

Command Protocol

Block DeviceMap Log

Datacenter S/W Infra

Storage Plugin Interface

KV Interface

Key Value APIThin KV Library

Key Value Glue Logic

KV Device Driver

Command Protocol

KV DeviceIndex Log

TX/s WAF, RAF, Latency

Index Log

Block Map

Index Log

25

Page 26: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value Software Development Stacks

Key Value Library & Tools

Cache AIO Multi-Queue Multi-Device Memory Manager

KV Abstract Device Interface (ADI)

Linux Kernel Device Driver Linux User-space Device Driver Windows Device Driver

store/retrieve/delete/exist KV Pair namespace

Tools

Page 27: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV API/Lib

KV ADI

kvbench: Key Value Benchmark Suite

Performance Profiler

Workload Generator

…RocksDB ForestDBWiredTiger

Filesystem

Block Device Driver

Block Device KV Device

KV Device Driver

Page 28: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

KV devices

Application

KV Virtualization

28

KV Virtualization

Key Space Distribution Load BalancingCapacity Management

Page 29: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value Software Development Stacks

Key Value Library & Tools

Cache AIO Multi-Queue Multi-Device Memory Manager

KV Abstract Device Interface (ADI)

Linux Kernel Device Driver Linux User-space Device Driver Windows Device Driver

store/retrieve/delete/exist KV Pair namespace

Tools

Page 30: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD Use Case Studies

Page 31: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Device

Key ValueStore

Benchmark

Use Case StudyScale-UpSingle Scale-Out

KV Stacksvs

NVMeoF

KVBench

Page 32: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Device

Key ValueStore

Benchmark

Use Case StudySingle

or

NVMeoF

KV Stacks

KVBench

Scale-Up Scale-OutSingle

Page 33: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Single Component Performance: RocksDB vs. KV Stacks

• RocksDB– Originated by Facebook and Actively used in their infrastructure– Most popular embedded NoSQL database – Persistent Key-Value Store– Optimized for fast storage (e.g., SSD)– Uses Log Structured Merge Tree architecture

• KV Stacks on KV SSD– Benchmark tool directly operates on KV SSD through KV Stacks

33

Page 34: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

RocksDB vs. KV Stacks Performance Measurement• Better Performance

– Lean software stacks– Overhead moved to device

• IO Efficiency– Reduction of host traffic to

devices

KV SSD

KV-PM983

Block SSD

PM983

VS.

Block Driver

RocksDB

Filesystem

Client: kvbench

Key Value ADI

Key Value API

KV Driver

KV Stacks

Hardware Intel(R) Xeon(R) CPU E5-2630 v3 @ 2.40GHz96 GB RAMPM983(Block) & KV-PM983 SSD

Software Ubuntu 16.04RocksDB v5.0.2 on XFS50M records, 16B Key, 4KB value

Page 35: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

0

1

2

3

4

5

6

7

8

9

RocksDB(PM983) KV Stacks(KV-PM983)0

2

4

6

8

10

12

14

RocksDB(PM983) KV Stacks(KV-PM983)

Performance: Random PUT• 8x more QPS (Query Per Second) with KV Stacks than RocksDB on

block SSD• 90+% less traffic goes from host to device with KV SSD than

RocksDB on block device

8x

* Workload: 100% random put, 16 byte keys of random uniform distribution, 4KB-fixed values on single PM983 and KV-PM983 in a clean state

12.7

1.0

Rela

tive

QPS

8.0

Dev

ice

IO/U

ser I

O

Page 36: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Device

Key ValueStore

Benchmark

Use Case Study

NVMeoF

vsKV Stacks

KVBench

Scale-OutScale-UpScale-UpSingle

Page 37: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Scale-Up Storage: RocksDB• Linear Scaling

– More devices, more throughput and capacity

• IO Efficiency– Reduction of host traffics

to devices• Less CPU utilization

– Small number of cores or less CPU utilization for performanceXeon E5 Skylake (24 Cores) Xeon E5 Skylake (24 Cores)

DRAM 768 (GB)SSD(1.92 TB)

SSD(1.92 TB)

SSD(1.92 TB)2.5” SSD(1.92 TB)2.5” SSD(1.92 TB)

NGSFF(1 TB)

SSD(1.92 TB)

SSD(1.92 TB)

SSD(1.92 TB)2.5” SSD(1.92 TB)2.5” SSD(1.92 TB)NGSFF KV

(1 TB)18 EA 18 EA

vs

RocksDB

XFS

Page Cache

RAID0

Block Driver

RocksDBRocksDBRocksDB

Client: kvbench

Page 38: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

0.0

5.0

10.0

15.0

20.0

25.0

30.0

35.0

1 6 12 18

RocksDB (PM983) - R KV Stacks (KV-PM983)

0

1

2

3

4

5

6

7

8

RocksDB (PM983) KV Stacks (KV-PM983)

Scale-up Performance: Random Key PUT• 15x IO performance over S/W key value store on block devices

# of SSDs

Rela

tive

QPS

Relative performance to the maximum aggregate RocksDB random Put QPS for 1 SSD with a default configuration for 1 PM983 SSD in a clean state.System: Ubuntu 16.04.2 LTS, , Ext4, RAID0 for block SSDs, Actual CPU utilization could be 70-90% at CPU saturation point.Workload: 100% puts, 16 byte keys of random uniform distribution for RocksDB v. 5.0.2, 4KB-fixed values, 24 RocksDB instances with 4 client threads, 50GB/Instance or 1.2TB Data is used

6.8-7.0

1.0

15x

Dev

ice

IO/U

ser I

O

Page 39: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

0

0.5

1

1.5

2

2.5

RocksDB (PM983) KV Stacks (KV-PM983)

Scale-up Performance: Sequential Key PUT• 3.4x IO performance over S/W key value store on block devices

39

Rela

tive

QPS

1.0

2.0

Dev

ice

IO/U

ser I

O

Relative performance to the maximum aggregate RocksDB random Put QPS for 1 SSD with a default configuration for 1 PM983 SSD in a clean state.System: Ubuntu 16.04.2 LTS, , Ext4, RAID0 for block SSDs, Actual CPU utilization could be 90% at CPU saturation point.Workload: 100% puts, 16 byte keys of random uniform distribution for RocksDB v. 5.0.2, 4KB-fixed values, 36 RocksDB instances with 1 client thread, 34GB/Instance or 1.2TB Data is used

0.00

5.00

10.00

15.00

20.00

25.00

30.00

35.00

1 6 12 18

RocksDB (PM983) - S KV Stacks (KV-PM983)

3.4x

# of SSDs

Page 40: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Device

Key ValueStore

Benchmark

Use Case StudyScale-Out

NVMeoF

vsKV Stacks

KVBench

Scale-Up Scale-OutSingle

Page 41: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

DBBench/KVBenchDBBench/KVBench

Scale-Out: RocksDB & KV Stacks Configuration

RDMA Fabric

RocksDBvs

KV Stacks

NVMeoFover

RDMA

Mission PeakKV-PM983 SSDs

…Software CentOS 7.3 w/ KV Target

NICs 2x 100GbE + 2x 50GbECPU Xeon 8160 CPU @2.10GHz

1-node 2-socket, 48-core 96-thread# SSDs 36x 1TB

Software CentOS 7.3 w/ KV SWNIC 2x 100GbE

CPUXeon E5-2699V4 CPU @2.20GHz1-node 2-socket44-core 88-thread

DRAM 256 GB

Client: kvbench Client: kvbench Client: kvbench Client: kvbench

Page 42: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Local vs NVMeoF PUT Latency

0

200

400

600

800

1000

1200

1 2 4 8 16 32 64 128

Average Latency

Local Avg

RDMA Avg

Queue Depth

Mic

rose

cond

s @Qdepth: 1-8Overhead: 4-7us

RDMASwitch

kvbench

Page 43: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

0

2000

4000

6000

8000

10000

1 - Client 2 - Client 3 - Client 4 - Client

# of KV Clients

Scaling w/ 2 KV Servers

RocksDB KV Stacks

Performance and Capacity Scale-Out: PUT Throughput

13.8X

0

2000

4000

6000

8000

10000

1 - Client 2 - Client 3 - Client 4 - Client

# of KV Clients

Scaling w/ 2 KV Servers

RocksDB KV Stacks

5.87X

Client RocksDB: CentOS 7.3, Ext4, RAID0 for block SSDs, Workload: 100% puts, 16 byte keys of random uniform distribution for RocksDB, 4KB-fixed values, 24 RocksDB instances with 8 client threads, 50GB/Instance or 1.2TB Data is used, Client KV Stacks: CentOS 7.3, KV Load Generator, 100% 4K PUTs, 16 byte keys, KV Server: Mission Peak w/ NVMeoF KV Target

KQPS

KQPS

9.4M 9.4M

1.6M680K

Page 44: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

0102030405060708090

100

CPU Utilization for Clients

0102030405060708090

100

1 38 75 112

149

186

223

260

297

334

371

408

445

482

519

556

0102030405060708090

100

1 41 81 121

161

201

241

281

321

361

401

441

481

521

561

Avg Utilization 10% Higher

Time Time Time

2.1 M QPS

Page 45: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD Standards

Bill MartinPrincipal Engineer

Memory Solutions Lab

Page 46: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD layers

e.g. KV SSD

KV Device

KV Protocol Provider Interface

KV Wire Protocol

SNIA KV Library

Application(s)

KV Protocol Client Interface

e.g. SNIA KV API

e.g. NVMe KV commands

e.g. C Library, Java, etc.Written by vendors, open source, etc.

KV API

Page 47: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD Standard Activities• NVMe

– Work on a technical proposal is being discussed by the NVMe working group

– The group is defining the scope of the work– This will be a new device type

• SNIA– A proposal for a Key Value API has been submitted to the SNIA Object

Drive Technical Working Group– Discussion on the minimum necessary commands to meet basic Key

Value needs is progressing

Page 48: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value, not Object Drive• Both standards efforts are focused on Key Value SSD not

Object Drive– Key Value is a means to submit a Key and put or get a Value– Object Drive would include more extensive commands to query the

Key Value database

48

Page 49: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

NVMe Extension for Key Value SSD• Defines a new device type for a Key Value device• A controller performs either KV or traditional block storage

commands

PUT GET DELETE EXISTS

Admin command

Identify commands for KV

Other non-block specific commands

New Key Value Commands

Existing Command Extension

Page 50: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

SNIA Key Value API• The Key Value API (Application Programming Interface) has been presented to SNIA for consideration in the

Object Drive Technical Working Group• Defines a Tuple

– Key– Value

• Defines KV specific constants– Max Key Lebngth– Alignment Unit

• Key type supported– 4 byte fixed– 8 byte fixed– Variable length character string– Variable length binary string

• The API defines the calls that an application may make to the Key Value device interface– These calls are independent of any specific implementation– These calls support the basic commands proposed for the NVMe standard

• Open/Close• Store/Retreive• Exist• Delete• Containers/groups

Page 51: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Call for Participation• NVMe work is proceeding in the NVMe working group

– www.nvmexpress.org• Contributors and Promoters have access to working proposals

• SNIA work is proceeding in SNIA Object Drive Technical Working group– www.snia.org

• Members may join the Object Drive TWG and have access to working proposals

51

Page 52: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Key Value SSD is a Scalable Solution with Better TCO

52

TCO reduction

CPU or server reduction

Dense performance and capacity scaling

Linear performance and capacity scaling

Lean host software stacksKV SSD

Scale-Up

Scale-In

Scale-Down

Scale-Out

Page 53: Key Value SSD Explained – Concept, Device, System, and … ·  · 2017-09-08Key Value SSD Explained – Concept, Device, System, and Standard. ... Physical Location / Offset. Index

Questions?

[email protected]