TIP 0416-11 ISSUED – 2002 REVISED – 2008 REVISED – 2015 2015 TAPPI The information and data contained in this document were prepared by a technical committee of the Association. The committee and the Association assume no liability or responsibility in connection with the use of such information or data, including but not limited to any liability under patent, copyright, or trade secret laws. The user is responsible for determining that this document is the most recent edition published. TIP Category: Automatically Periodically Reviewed (Five-year review) TAPPI Recommended test procedure for black liquor evaporators 1.0 Scope Procedures used to measure the performance of black liquor evaporators and concentrators have frequently produced inconsistent and confusing results. There are two underlying causes for this problem. One is a lack of understanding of how to measure work done by an evaporation system. The second is that no standard evaluation procedure is available. This Technical Information Paper (TIP) establishes recommended test requirements for an accurate evaluation of black liquor evaporators. The evaluations discussed are for maximum rate evaluation, performance evaluation, and troubleshooting. It further describes procedures to fulfill test requirements for each. A general understanding of evaporators and the kraft chemical recovery cycle by the user is assumed. Pulp and Paper Manufacture: Volume 5-- Alkaline Pulping (1) gives extensive background on evaporators for others. Definitions are listed to ensure common understanding of terms. This TIP does not specifically include items unique to evaluation of black liquor concentrator systems; however, it can be used as a guide for evaluation of such systems. 2.0 Definitions See Appendix A 3.0 Safety precautions Due to the nature of the kraft pulping process, several substances are generated in the black liquor evaporation system that requires special care. The entire evaporation process is conducted at relatively high temperatures, approaching and in select applications exceeding, 300ºF (150 o C). Consequently, the fluids used in the process are at elevated temperatures and pressures. Therefore, high temperature and pressure precautions must be taken when opening sample valves, servicing instrumentation, servicing steam traps, etc. Black liquor used in the process is caustic and can cause severe chemical burns, if not properly handled. Extreme caution must be used when working around black liquor. Wear personal protective equipment (PPE) and use safety procedures related to evaporators, black liquor, and hot surfaces developed for the specific mill and company. Non-condensable gases (NCG) generated in the evaporation process are potential safety hazards. Some of the vapor components are explosive and easily ignite (for example, methanol and turpentine). Others, such as hydrogen sulfide, are extremely hazardous and can be fatal if inhaled at certain concentrations. When working in these areas, it is essential to know and practice mill and company safety procedures related to evaporators, NCG, and area or personal hydrogen sulfide monitors. The evaporation system can be a dangerous place if we do not take precautions. Although evaporator bodies have been

Key Process Indicators-Falling Film Evaporators

Embed Size (px)

DESCRIPTION

What are the key process indicators to determine how efficient how efficient our MVR is operating

Citation preview

Page 1: Key Process Indicators-Falling Film Evaporators

TIP 0416-11

ISSUED – 2002 REVISED – 2008 REVISED – 2015

2015 TAPPI

The information and data contained in this document were prepared by a technical committee of the Association. The committee and the Association assume no liability or responsibility in connection with the use of such information or data, including but not limited to any liability under patent, copyright, or trade secret laws. The user is responsible for determining that this document is the most recent edition published.

TIP Category: Automatically Periodically Reviewed (Five-year review)

TAPPI

Recommended test procedure for black liquor evaporators

1.0 Scope Procedures used to measure the performance of black liquor evaporators and concentrators have frequently produced inconsistent and confusing results. There are two underlying causes for this problem. One is a lack of understanding of how to measure work done by an evaporation system. The second is that no standard evaluation procedure is available. This Technical Information Paper (TIP) establishes recommended test requirements for an accurate evaluation of black liquor evaporators. The evaluations discussed are for maximum rate evaluation, performance evaluation, and troubleshooting. It further describes procedures to fulfill test requirements for each. A general understanding of evaporators and the kraft chemical recovery cycle by the user is assumed. Pulp and Paper Manufacture: Volume 5-- Alkaline Pulping (1) gives extensive background on evaporators for others. Definitions are listed to ensure common understanding of terms. This TIP does not specifically include items unique to evaluation of black liquor concentrator systems; however, it can be used as a guide for evaluation of such systems. 2.0 Definitions See Appendix A 3.0 Safety precautions Due to the nature of the kraft pulping process, several substances are generated in the black liquor evaporation system that requires special care. The entire evaporation process is conducted at relatively high temperatures, approaching and in select applications exceeding, 300ºF (150oC). Consequently, the fluids used in the process are at elevated temperatures and pressures. Therefore, high temperature and pressure precautions must be taken when opening sample valves, servicing instrumentation, servicing steam traps, etc. Black liquor used in the process is caustic and can cause severe chemical burns, if not properly handled. Extreme caution must be used when working around black liquor. Wear personal protective equipment (PPE) and use safety procedures related to evaporators, black liquor, and hot surfaces developed for the specific mill and company. Non-condensable gases (NCG) generated in the evaporation process are potential safety hazards. Some of the vapor components are explosive and easily ignite (for example, methanol and turpentine). Others, such as hydrogen sulfide, are extremely hazardous and can be fatal if inhaled at certain concentrations. When working in these areas, it is essential to know and practice mill and company safety procedures related to evaporators, NCG, and area or personal hydrogen sulfide monitors. The evaporation system can be a dangerous place if we do not take precautions. Although evaporator bodies have been

Page 2: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 2

designed with the safety of mill personnel as a chief concern, specific safety procedures must be followed when performing work in and around the system. One must always use care when opening a valve that releases hot fluid into the atmosphere to avoid being severely burned by splattering fluid and/or flashing steam. Always stand to one side of the opening and use appropriate PPE. Do not open any drain valve on a vessel or pipe that contains hot black liquor above its atmospheric boiling point, i.e., under pressure. When the conditions behind the valve are unknown, always assume the process is under pressure with temperature above the atmospheric boiling point. Cool and dilute the stream before draining. Be extremely careful not to open a sample valve and be driven away by heat and/or vapor so that the valve cannot be closed. 4.0 Procedure Figure 1 is a flowchart which summarizes the steps detailed in this procedure. The chart indicates early decision points and then the sequence of preparatory work, data acquisition, generation of critical information and data evaluation leading to decision points around output reporting or measures for troubleshooting. Each step references the numbered section(s) of text that describes the corresponding material and procedures. An evaporation system transfers heat from one fluid to another. The amount of work performed can be quantified in several ways, such as: The quantity of heat that is transferred (Btu/h, GJ/h). Evaporation rate (lb water/h, kg water/h). Solids throughput rate from one solids concentration to another (lb/h or kg/h dry solids from, e.g., 15% to 65%). Evaporation rate or solids throughput rate are the most suitable measurement methods for specifying this work. Each of these takes into account the three most significant variables affecting the quantity of work: feed liquor concentration, product liquor concentration, and liquor feed rate. If any or all of these change, the evaporation rate will be accordingly influenced. 4.1 Key process performance criteria Six criteria are typically used to judge overall evaporation system performance. All or selected ones may be test objectives. Maximum evaporation rate Dry solids throughput rate Product dry solids content Overall steam economy Surface condenser outlet water temperature Process condensate quality These criteria are discussed in subsequent sections. It is important to have full agreement on test objectives between the client and the test group to ensure that the selected evaporator criteria are achieved and that all necessary data are collected. It is highly desirable, and in many cases mandatory, that all criteria are simultaneously met within a given test. Adjustments are possible for some of the parameters via calculations after the test, if simultaneous achievement of all process conditions cannot be achieved. These cases are covered in Section 5.0. Another important criterion is operational time between evaporator cleanings, i.e., boiling of selected bodies, full set boil out, or hydroblasting of selected bodies. An agreed upon long-term monitoring and evaluation plan needs to be developed to evaluate run time performance. This TIP does not address such a plan, although, in general, many of the techniques used to evaluate short-term performance can also be used for long-term monitoring.

Page 3: Key Process Indicators-Falling Film Evaporators

3 / Recommended test procedure for black liquor evaporators TIP 0416-11

Fig. 1. Flowchart of procedure 4.2 Process flow diagram and heat transfer surface area An accurate flow diagram showing the overall liquor, steam, vapor, NCGs and condensate flow patterns is required. In many cases, the original design drawing will not reflect the present system. Therefore, the person conducting the evaluation must verify the process equipment, flows, and data on the flow diagram or make a completely new diagram.

Page 4: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 4

A simple block diagram is sufficient in most cases. Heat transfer surface area is required for each evaporator body, liquor heater and surface condenser; this can be obtained from original design drawings, but may need to be modified for plugged tubes or blanked lamella (plate) elements as noted in the field data collection section. 4.3 System requirements for evaporator evaluation Evaluations to establish evaporator production capability or compliance with vendor guarantees require a high degree of accuracy. High accuracy performance data yields a more accurate evaluation. Mill instrumentation, while generally adequate to record daily operating parameters and to provide troubleshooting trend data, seldom meets the requirements for an accurate performance test. For these evaluations, the following minimum instrumentation is recommended: Operating pressures (calibrated precision electronic manometer, or calibrated pressure gauge and vacuum gage) Operating temperatures (precision thermometers or infrared pyrometer) Liquid flows (mill instrumentation noting discussion later in the field data section) Liquor solids concentration (oven drying tests, TAPPI T 650 "Solids Content of Black Liquor") The following is an explanation of each of the evaluation steps. Forms to aid in collecting and recording the required data are enclosed as Appendices B and C. Appendix B, Field Data Summary, summarizes performance data recorded in the field from system performance. Appendix C, Laboratory Analysis, summarizes data obtained from laboratory analysis of test samples. 4.4 Field data Field data must be taken during the shortest possible time interval while the evaporator is operating at steady conditions and at its maximum sustained rate (MSR) for at least 4 hours before collecting data. Other process areas that affect the liquor cycle should also have been operating at typical and steady conditions, ideally 24 to 72 hours. The key areas are:

Digester (wood species and quality, alkali charge, and H-factor) Washers (dilution ratio, black liquor solids from last washer) Soap skimmer (in typical operating mode, if applicable) Recausticizing area [causticizing efficiency, white liquor (TTA, AA & sulfidity), make-up chemical flow (s)] Recovery boiler reduction efficiency.

Care should be taken to ensure that liquor and condensate samples are representative of each applicable stream. The type of flow meter used to obtain flow measurements should be noted to permit evaluation of flow rate discrepancies. Field data collection is important, but it is only as good as the methods for obtaining it. When taking pressure readings, check the connection to ensure it is free of fiber, scale, or other debris. Drain any condensate or liquor from the sample line that would give inaccurate readings. Before getting liquor samples, thoroughly flush sample ports. This is generally indicated when its discharge temperature has stabilized at the “hot” condition. For samples near or above flashing temperature, run the sample line through a cooler before taking the sample to get the best representation of the liquor solids as well as for safety reasons. Fill the sample bottle completely and cap it tight immediately to prevent evaporation loss and a non-representative sample. The following field data is recommended: Obtain the following flow rates from mill instrumentation: Feed liquor (s) at each entry point (if a return “sweetening” liquor is used, measure total feed downstream

of entry point and the sweetening liquor flow) Product liquor (s) (review relative accuracy of this flow compared to the feed liquor flow with the mill) Any liquor streams leaving and re-entering the evaporator, e.g., liquor to/from the soap skimmer, ash mixing Chemical streams entering after the weak black liquor flowmeter (s)

e.g., salt cake, boiler ash, ClO2 spent acid, crude tall oil brine, caustic, and boil out reclaim Process condensates and flash vapors (likely via calculations) from other processes, if available Steam, including steam supplied to an integrated condensate stripper Steam condensate (s), if available

Page 5: Key Process Indicators-Falling Film Evaporators

5 / Recommended test procedure for black liquor evaporators TIP 0416-11

Desuperheating water, if available Surface condenser water Fluids heated by evaporator vapors, e.g. demineralized boiler feedwater Foul condensate flow to steam stripper, if one is integrated into the evaporators Obtain the following pressures using portable, calibrated gauges and from trusted mill instrumentation where

available. Preferably, measurements from the portable calibrated gauge are compared to the mill instrumentation: Surface condenser (s), vapor side inlet Non-condensable gas line to vacuum system (ejector or vacuum pump) NCG pipes around the ejectors or vacuum pumps Each effect, liquor side (vapor head) Each effect, steam/vapor side (only if pressure drop between effects is required) Steam, both upstream and downstream of the control valve Product flash tank (s) vapor pressure (alternately, product liquor temperature at pump suction) Condensate flash tank (s) vapor pressure (alternately, condensate temperature at pump suction) Record temperatures listed below. Glass laboratory thermometers provide good results, if open streams are

available. Alternately, portable IR sensors can be used on uninsulated non-reflective bare pipes or reflective pipes with a flat-black paint spot. Also record temperature data from mill RTD-type sensors, where available.

Feed liquor, downstream of any sweetening liquor, brine addition, or other additions as applicable Product liquor Surface condenser cooling water inlet and outlet Non-condensable gas line to vacuum system (ejector or vacuum pump) NCG pipes around the ejectors or vacuum pumps Liquor out of each body Internal and external liquor heater(s) inlet and outlet liquor temperatures Liquor to/from the soap skimmer NCG vent temperature at each body, both directly upstream and downstream of throttling valve or orifice plate Steam temperature at the steam flowmeter, typically upstream of the desuperheater and control valve Steam temperature downstream of the desuperheater Desuperheater water temperature If a stripper is integrated, the following temperatures are also required:

Stripper feed condensate out of preheater or into column Stripped condensate from column / to preheater

Obtain the following liquor/condensate samples: Weak liquor feed(s), downstream of any sweetening liquor addition Product liquor from each body (especially important for parallel bodies and if checking for leaks within bodies) Liquor to and from salt cake pick-up Product liquor(s), upstream of any sweetening liquor take off Steam condensate(s) Clean process condensate(s) each fraction produced Foul process condensate(s) Operating conditions at the time of the evaluation must be documented. List any factors affecting performance per the following examples: Liquor levels in bodies via sight glasses or level sensors, especially if out of range Fiber content of the black liquor feed Condensate levels in bodies, especially if high or below minimum indication Document evidence of foaming Liquor content in condensate (conductivity or Na content) Describe any abnormal pump performance (have experienced operator review motor current readings and pump

noise levels) Stability of the system pressure profile (i.e. any “swinging”?) Document swings using PI or DCS printouts

Page 6: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 6

Condition of internal / external liquor heaters (in / out of service?) Vent control strategy for flash tanks (auto / manual and temperature / pressure) and valve position Control strategy for product solids (auto / manual and measurement method) Type of vacuum system (ejector or vacuum pump) Temperature of non-condensable gases from the surface condenser and pre-cooler ahead of the vacuum system Time since last full and partial boil out Boil out frequency and media used Number of mechanically plugged tubes or blanked plate elements in each body including condensers (maintenance

records) Soap skimmer performance (residual soap) Recausticizing area performance (causticizing efficiency) Recovery boiler reduction efficiency Type of wood furnish 4.5 Laboratory analysis The following laboratory analyses are required: Oven dry solids on all liquor samples (use TAPPI T 650 “Solids Content of Black Liquor”). Feed and product solids

should be performed in duplicate or triplicate. Feed and product liquor specific gravity TAPPI T625 “Analysis of Soda and Sulfate Black Liquor” or

equivalent method to determine specific gravity at liquor flow meter temperature (correlations given in references 2-4 or tabulations e.g., Appendix D may also be used).

Liquor boiling point rise (BPR curve). This analysis is best done on the current liquor by a laboratory with this capability. If this cannot be done, use the design BPR data for the set to construct a curve. Alternatively, the vapor pressure in each vapor head can be converted to a saturation temperature and subtracted from the temperature of the liquor exiting each body then compared with the measured solids from each body to determine an approximate BPR curve.

4.6 Raw data evaluation From the raw data, calculate the mass feed rate, solids rate, product rate and evaporation rate. As a check, compare the solids rates based on both feed and product flows and percent solids. Discrepancies normally occur between the two solids rates. Since the product rate is a smaller flow and typically has more variability, the feed rate generally offers a higher degree of accuracy, unless there is reason to believe the feed flow measurement is more variable. Some processes are configured for product flow rate control. In these cases the product flow and percent solids should be used. These calculations involve liquor flows, TAPPI oven-dry solids tests, and liquor specific gravity. Each of these values should be checked. Solids determination TAPPI T 650 should be accurate to ± 0.10% solids units. Shortcut methods are rarely better than ± 0.50% solids units. Specific gravity values Specific gravity at a given liquor concentration and temperature can be estimated from tables such as Appendix D (supplied by Kadant/ Chemical Pulping Division). References 2-4 show specific gravity data and provide equations to estimate black liquor specific gravity as functions of total solids content and temperature. Appendix D and the equations in References 2-4 agree to within approximately 0.2% up to 50% solids. When possible it is best to measure the specific gravity of the actual liquor. Flows Flow measurements are the most likely source of discrepancies. Evaluate sensor type from which measurements were obtained and determine if one flow should be more reliable than another. Magnetic flow meters or mass flow meters are generally more accurate than other types such as orifice meters. The recovery boiler flow meter and firing solids

Page 7: Key Process Indicators-Falling Film Evaporators

7 / Recommended test procedure for black liquor evaporators TIP 0416-11

instrumentation are usually well maintained and calibrated and can be used to determine the relative accuracy of the feed and product flow meters. Tank draw down or fill rates can be used to check flow meter accuracy. The steam flow meter can be checked either by condensate flow measurements or by comparison with the steam flow calculated from an overall mass and energy balance (discussed below). The remaining data should also be reviewed and graded according to its potential accuracy. Identify reliable performance benchmarks. Discard inconsistent or less reliable data. All of the remaining data then become the basis for system evaluation. 4.7 Mass and energy balance Show calculations to:

1. Determine the feed flow (lb/h or kg/h), including density correlation at the liquor temperature and tested solids. 2. Determine the feed solids flow (lb solids/h or kg solids/h). Feed solids rate (lb solids /h or kg solids/h) = Feed rate (lb/h or kg /h) Feed solids (% T.S.)) / 100 e.g. for a system

processing 1,000,000 lb/h weak liquor at 15% T.S. the solids feed flow rate = 1,000,000*15%=150,000

3. Determine the product flow (lb/h or kg/h) and product solids flow (lb solids/h or kg solids/h). Product solids rate (lb solids/h or kg solids/h) = Product rate (lb /h or kg /h) product solids (%)) / 100

4. Compare feed and product solids flows, accounting for loss in the soap skimmer. Dry solids flow checks between feed and product solids should be within 0.5 %.

5. Determine the steam flow to the evaporator

a. If steam desuperheating water is taken from the evaporator’s clean steam condensate pump, then the actual steam consumption in the process is the steam flow prior to desuperheating.

b. If steam desuperheating water is taken from a treated mill water source outside the evaporator process boundaries, like boiler feedwater or sweetwater condenser, then the steam consumption in the process is the sum of superheated steam flow and the theoretical desuperheating water flow (amount of water required to decrease the steam temperature from header conditions to actual temperature entering the steam chest).

6. Calculate the evaporation rate (feed rate minus product rate minus loss in soap skimmer, unless there is a large discrepancy in the feed and product solids flow). If solids flow between the feed and product is more than 0.5% apart, then new data should be collected. If no product flow meter exists, then calculate evaporation rate based on the feed liquor flow meter, tested feed percent solids, and tested product percent solids. Use the product flow and percent solids if this is the rate control for the set. Note in processes where ash (salt cake) addition takes place within the evaporator system, it is necessary to account for the added ash. In this case the evaporation rate is equal to: (feed rate + ash addition – product rate – soap skimmer losses)

7. Calculate steam economy (lb evaporation per lb steam): evaporation rate divided by steam rate.

8. Input the surface area for each heat transfer body in the evaporator and the field data into a mass and energy balance program specifically written for the set being tested. This is usually available through the manufacturer. Optionally, the owner can develop / purchase this capability. The general approach to such a calculation and an example are shown in Reference 1, pp. 502−511. Compare the heat transfer coefficients in each body with design values to ensure that all bodies are performing as designed. A lower heat transfer coefficient on any body indicates potential problems, see Section 8.0.

9. Close the mass and energy balance and validate the evaporation rate obtained in Step 6 with the mass and energy balance result in Step 8. Mass and energy balance closure of at least 95% is typically achievable with good data.

These calculations can be set up in a spreadsheet or process simulator for subsequent performance evaluations through-out the life of the set.

Page 8: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 8

5.0 Performance evaluation It is not unusual for the operating conditions represented by a reference mass and energy balance to be different from those for which performance data is desired. In such cases, it is necessary to make adjustments. Possible differences in conditions are listed below: Variation in steam pressure and / or surface condenser vacuum and / or liquor boiling point rise. Differences in feed concentration, product concentration and/or solids rate. Differences in feed liquor temperature. Differences in liquor composition. Adjustments for the first three of these are discussed below. Note that differences in liquor composition are discussed but only qualitative adjustments are possible. Adjustments for differences in steam pressure, surface condenser vacuum, and boiling point rise Three parameters -- steam pressure, surface condenser vacuum and liquor boiling point rise -- collectively define the systems’ available ΔΤ which is the driving force for heat transfer (see Appendix A). Differences between the design and actual values of each these parameters will impact the set’s overall evaporation capacity. The evaporation rate will change in direct proportion to a change in available ΔΤ. An adjustment factor for the overall evaporator ΔΤ available is defined to compensate for differences between actual and target conditions as follows. ΔT available target ΔT Adjustment factor = D = ΔT available actual where: ΔT Available target = Saturated steam temp target – Condenser vapor temp target – sum of BPR’s target for all effects ΔT Available actual = Saturated steam temp actual – Condenser vapor temp actual – sum of BPR’s actual for all effects Note: the vapor temperature at the condenser can only be used if the pressure drop between the surface condenser shell and the vapor head of the last effect is negligible i.e. less than 0.2 in. Hg (0.7 kPa), otherwise use the saturation temperature of the vapor head of the last effect for this calculation to attain a true net available ΔT. Adjustments for differences in feed concentration, product concentration and / or solids throughput rate Differences in feed and product solids also affect evaporation rate. For example, at a specified liquor solids throughput rate, if feed solids concentration is lower than the target value, the work required (evaporation rate) to achieve the target product solids is greater. Compensations for this difference can be handled in a mass and energy balance, or an adjustment factor can be determined by comparing the evaporation rate for the actual evaluation conditions to that for the target conditions. The procedure for calculating this adjustment follows. Actual solids rate = Sactual = Actual Feed Rate, lb/h or kg/h Feed Concentration, % T.S./ 100 Target solids rate = Starget = Target Feed Rate, lb/h or kg/h Feed Concentration, % T.S./ 100 Sactual Sactual

Actual evaporation rate = Eactual = − FCactual /100 PCactual /100 Starget Starget

Target evaporation rate = Etarget = − FCtarget /100 PCtarget /100

Page 9: Key Process Indicators-Falling Film Evaporators

9 / Recommended test procedure for black liquor evaporators TIP 0416-11

Etarget Adjustment factor = S = Eactual where FCactual = actual feed concentration, % FCtarget = target feed concentration, % PCactual = actual product concentration, % PCtarget = target product concentration, % Adjustments for feed liquor temperature Differences in the feed liquor temperature can have a significant impact on steam economy and to a lesser extent on throughput rate. Adjustments for feed temperature differences must be made in mass and energy balances. Variations in liquor composition The effect of liquor composition can have a profound effect on performance of evaporators both in terms of physical properties, e.g., boiling point rise and viscosity, and chemical properties, e.g., scaling tendency. The liquor components of primary interest are listed in Troubleshooting Section 8.0, item 9. There is no systematic way at this writing to quantitatively adjust evaporation rate capability for composition variation. A comparison of composition data, boiling point rise and viscosity measurements between baseline and test liquors and an adjustment based on experienced judgment is the best approach presently available. This is why wood species/quality and digester cooking conditions need to be as typical as possible when the performance test is performed. Adjusted evaporator rate The two quantitative adjustment factors specified above are to be used as follows: Adjusted evaporation rate = Eactual D S 5.1 Condensate quality Condensate quality parameters include: conductivity (influenced mainly by sodium), biological oxygen demand (BOD), and methanol content. Conductivity is typically used for mill measurements. Steam condensate will be the cleanest with the lowest conductivity while foul process condensates will have the highest conductivity. Conductivity of a specific process condensate stream is a relative indicator of black liquor carryover. Black liquor carryover into condensing vapor and then into the process condensate is to be minimized. The amount of carryover can be determined by testing the amount of sodium in the various condensate streams. It is important to compare actual clean and foul condensate conductivities and/or sodium levels with either design specifications or with best operating data, depending on the test objectives. There may also be a need to sample condensate for BOD or methanol content related to treatment system evaluations. For these analyses special sampling procedures are required to prevent volatiles loss during flashing. Tests for BOD are to be conducted in accordance with EPA Procedure 308. Tests for methanol should be in accordance with National Council for Air and Stream Improvement (NCASI) procedures. 6.0 Verification If the purpose of the evaluation is to compare actual performance with the vendor’s design performance, comparison of the adjusted evaporation rate from the Section 5.0 with the design evaporation rate supplied by the vendor should suffice.

Page 10: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 10

6.1 Contractual considerations If evaporator testing is to be done to satisfy an equipment sales performance guarantee or another multiple party business contract, mutual agreement needs to be established in a number of key areas. These include: Test length, number of tests and "load points" to be tested. Performance data to be demonstrated. Configuration to be evaluated (process flow diagram). Sample location for primary lab samples and test values. Test methods and laboratory to be used. Method to be used for mass and energy balance. Heat losses to ambient and to non-condensable gas system (i.e., venting and radiation losses). Accuracy of test data to be demonstrated (e.g. ±5%, ±10%). Criteria for interrupting test, restarting test or extending test length. Critical site-specific parameters and properties not otherwise documented. Method of correcting test values to guarantee conditions. If applicable, criteria for accepting performance. 7.0 Upgrade basis If the purpose of this evaporator evaluation is to determine the best way to increase capacity of an existing system, it will be necessary to find ways to increase the work done by the system. Possibilities are as follows: Increase the heat transfer coefficient, U. (e.g., reduce liquor fouling potential, reduce liquor viscosity, increase

cleaning frequency, increase heat flux, tube surface modifications, and tube inserts) Increase the overall system ΔT (e.g., increase steam pressure, increase vacuum, decrease pressure drops

between bodies, or reduce boiling point rises) Remove sensible heat load (e.g., convert out-of-service internal liquor heaters to evaporation service and add

external liquor heaters) Increase body heat transfer area (repair plugged tubes or blanked plates) Eliminate dilution water from sealed bearings (mechanical seals) Reduce product solids, shifting the corresponding evaporation load to another evaporator or concentrator set Reduce number of effects (significantly reduces steam economy) Change liquor flow path (low probability) Recognizing the complexity of a multiple effect evaporator set, a new mass and energy balance at the required new evaporation rate is essential for making intelligent choices. 8.0 Troubleshooting The most accurate method for troubleshooting performance of an evaporation system is to compare its current performance to its performance when the evaporation system was operating well and/or to its design performance. First, compare the current steam economy and overall heat transfer coefficient to both the latest design balance and past performance evaluations. If there are significant deviations, then a full evaluation of the set will be required, so that individual body heat transfer coefficients can be evaluated. A guideline for troubleshooting including the balance work follows: 1. Check system instrumentation to ensure functionality.

2. Pick appropriate target operating conditions.

3. Operate system at steady state during data acquisition.

Page 11: Key Process Indicators-Falling Film Evaporators

11 / Recommended test procedure for black liquor evaporators TIP 0416-11

4. Obtain the following data: Feed liquor, flow rate and temperature Product liquor, flow rate and temperature Liquor or chemical streams leaving and entering the evaporator, flow rate and temperature Steam, flow rate, pressure and temperature downstream of control valve Stripper feed condensate, flow rate and temperature Stripped condensate, flow and temperature Liquor heater(s), temperature in and out Each effect, liquor temperature and vapor pressure Each liquor flash tank, liquor temperature and vapor pressure Each condensate flash tank, flow, temperature and vapor pressure Surface condenser vacuum Condenser water, flow rate and inlet / outlet temperatures Temperature and pressure of NCG line from surface condenser to ejector or vacuum pump.

5. Obtain the following liquor samples: Feed liquor (s) at each entry point. If a return “sweetening” flow is used, sample downstream of its entry point. Product liquor Discharge liquor from each transfer pump (optional if mass and energy balance conducted) Liquor or chemical streams entering the evaporator.

6. Perform the following basic laboratory analyses: Obtain percent solids of each feed and product sample Obtain percent solids and pH of each chemical stream (e.g. brine) added to the feed liquor Obtain percent solids of each transfer pump liquor sample. Alternately, obtain from mass and energy balance Obtain boiling point rise data. Alternately, use design and/or past data.

7. Check and record the following: Are level gauge glasses operational? Are there any high condensate levels in the bodies, heaters, or surface condenser(s)? Is there evidence of foaming? Is steam condensate conductivity OK? Is process condensate conductivity OK? Is precooler section of condenser or external precooler near target temperature?? Do NCG ejectors have clean, dry steam at design pressure (if present)? Are inter and after condensers properly working (if present)? Is NCG vacuum pump working properly (if present)? Is the ejector NCG suction temperature consistent with the NCG temperature vented from the condenser? Are any pumps cavitating? Are any pump seals leaking water or air into the system? How many tubes are plugged (or blanked plates) in each body? At what level is soap skimmer liquor/soap interface, e.g., temperature transition? How long since last boil out and hydroblast? What is average boil out frequency? What wood is being pulped? What is fouling potential of liquor based on its liquor composition? Has the caustizing area been operating in a stable manner (What is the CE trend)?

8. Calculate mass and energy balance (general approach and example shown in Reference 1, pp. 502 - 511): Adjust the area of each body for known plugged tubes or blanked plates. Compare current heat transfer coefficients and ΔT values for each body with latest design and past balances. For each body and external heater. Note significant differences in solids and temperature between these balances for a given

body. Low heat transfer coefficient(s) and high ΔTs? If not explained by differences in liquor solids

or temperature or time since last cleaning, these identify the body (or bodies) that is (are) decreasing the entire set’s overall performance.

Page 12: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 12

9. Obtain liquor analyses including the following and compare against design and past performance data: TAPPI T 650 solids Carbonate Sulfate Sodium Potassium Residual effective alkali (SCAN-N 33-94) Residual sulfide (SCAN-N 31-94) Oxalate Calcium (total and insoluble) Aluminum Silica Magnesium Fiber content (typically fraction of dry solids retained on a 100 mesh screen) Insoluble soap (see Appendix E for sampling guide) pH Viscosity versus solids curve and correction from lab temperature/pressure to process conditions Determine the solubility limit (see Reference 1, pp. 522 - 523 for estimation method)

For evaporator bodies operating above the solubility limit, calculate the carbonate-to-sulfate ratio for guidance on managing soluble scale (5) For liquors with oxalate content over 0.3 wt % of dry solids, determine the solubility limit for sodium oxalate (6)

10. Evaluate performance as follows: Evaporation rate (lb/h or kg /h) = Feed rate (lb/h or kg/h) Product rate (lb/h or kg/h) Loss in soap skimmer

(lb/h or kg/h). See previous comments regarding systems with ash addition. Solids ratefeed (lb/h or kg/h) = Feed rate (lb/h or kg/h) (% Feed solids) / 100 Solids rateproduct (lb/h or kg/h) = Product rate (lb/h or kg/h) (% Product solids) / 100 Note: A difference in these two solids rates, corrected for soap skimmer loss, by more than 0.5% represents a

flaw in data. Steam economy = Total evaporation rate divided by total steam used (not including steam for ejectors) 11. In the event test conditions are different from reference performance data available for the comparison, the

adjustment factors outlined in the Section 5.0 can be used to correct performance values. 12. Compare the adjusted data to the mass and energy balance for the reference condition to find differences that could

indicate a problem, such as: Steam flow rate and steam economy. Differences in delta T and heat transfer coefficient for each body and heater. Surface condenser vacuum.

13. The evaluation cannot be considered complete unless it includes an inspection of the interior of each body during a

shutdown. Look for symptoms indicated by the mass and energy balance and the following: Check integrity of the NCG removal system. Steam nozzle condition; inter and after condenser tube condition Conduct a hydrostatic test on the tube side of each body including condenser. Check pluggage or damage to entrainment separators including seal pots where equipped. Look for plugged or damaged tubes or plates in evaporator bodies and condensers. Look for damage or debris in liquor boxes and condenser water boxes. Look for damage or missing gaskets on all internal heaters. Check for build up of material opposite the liquor inlet nozzle in the bottom liquor box on LTV bodies

Page 13: Key Process Indicators-Falling Film Evaporators

13 / Recommended test procedure for black liquor evaporators TIP 0416-11

Look for missing or misaligned impingement plates, scale on tubes or plates and fiber buildup on the vapor side. Check condition of condenser tubes or plates, both inside and outside. Check condition of umbrella baffle on LTV evaporators and look for impact patterns under the umbrella that indicate patterns in tube flow. Check for plugged distributor plate holes in falling film evaporators. Check condition of NCG ejector nozzles.

14. For black liquor evaporator bodies and concentrators operating generally above 50% solids concentration, determination of solubility limits or crystallization points (commonly known as critical solids of black liquor) will help define feed and product liquor solids concentrations, sweetening liquor flow requirements, and other factors to manage soluble scale fouling in bodies which must support crystallization of sodium salts. This is a relatively new and advanced subject beyond the scope of the present TIP, but discussed elsewhere (5÷7).

See Pulp and Paper Manufacture: Volume 5 -- Alkaline Pulping (1, pp. 526 -528), and several other references (8-14 for additional information on evaporation system troubleshooting.

9.0 Keywords Evaporators, Black liquors, Heat transfer, Heat transfer coefficient, Testing, Troubleshooting 10.0 Additional information Effective date of issue: March 31, 2015 Working Group:

Christopher Verrill, Chair, International Paper Jim Straka, Lundberg Dan Bloom, Lundberg Jason Smith, Kadant Jim Bradbury, Verso Will Krepps, MeadWestvaco Corporation

Literature cited 1. Grace, T.M., Malcolm, E.W., Eds., Pulp and Paper Manufacture Volume 5 Alkaline Pulping, Chapter XIX, pp. 477

-530, Technical Section Canadian Pulp & Paper Association, 1996. 2. Green, R.P., Hough, G., Ed., Chemical Recovery in the Alkaline Pulping Processes, Chapter 2, pp 5-6, TAPPI Press,

1992. 3.. Adams, T. N., Ed., Kraft Recovery Boilers, Chapter 3, pp 86-90, TAPPI Press, 1997. 4. Gullichsen, J., Fogelholm, C.-J., Eds., Chemical Pulping, Paper Making Science and Technology Book 6B, Chapter

11, pp B18-19, Fapet Oy, 1999. 5. DeMartini, N., Verrill, C.L., “Minimizing soluble scales in black liquor evaporators: Application of metastable and

solubility limit data for the Na-CO3-SO4 system,.” 2007 International Chemical Recovery Conference Proceedings, pp 479-483 (May 2007).

6. DeMartini, N., Verrill, C.L., “Evaporator fouling mitigation - case studies,” 2005 TAPPI Engineering, Pulping and

Environmental Conference Proceedings, Paper 34-2 (July 2005).

Page 14: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 14

7. Frederick, W. J., Jr., Euhus, D. D., “A practical approach to eliminating inorganic scaling in black liquor

evaporators and concentrators,” TAPPI PEERS Conference Proceedings, Paper 30-2 (September 2014) 8. Clay, D. T., “Evaporator and Concentrator Design Considerations for Troubleshooting,” 2008 TAPPI Engineering,

Pulping, and Environmental Conference Proceedings, Paper 28-2 (August 2008). 9. Corcoran, M., Rieke, J.F., “HPD Systems Evaporator Troubleshooting,” 2003 TAPPI Fall Technical Conference:

Engineering, Pulping, and PCE&I Proceedings, Paper 58-1 (October 2003). 10. Goodwin, A., Almond, C., “Troubleshooting Two Vacuum Problems, TAPPI Fall Technical Conference:

Engineering, Pulping, and PCE&I Proceedings, Paper 58-2 (October 2003). 11. Almond Jr., C. B., “Evaporator Troubleshooting Techniques,” Southern Pulp and Paper, pp 30-36 (August 1982). 12. Lankenau, H. G., Badyrka, J. T., “Multiple-effect evaporators: problems and troubleshooting, Part I,” Tappi J. 65

(2):75-76 (1982). 13. Lankenau, H. G., Badyrka, J. T., “Multiple-effect evaporators: problems and troubleshooting, Part II,” Tappi J. 65

(3):153 (1982). 14. Swartz, A., “A guide for troubleshooting multiple-effect evaporators,” Chemical Engineering, pp 175-182 (May 8,

1978). Appendix A. Definitions Boiling point rise, BPR – All liquids with dissolved solids exhibit a physical property known as boiling point rise (BPR). The BPR is the temperature rise above the boiling temperature of the pure solvent at which the solution boils. The BPR is dependent on the concentration of dissolved solids and increases with concentration. BPR is also somewhat dependent on system pressure. In general, BPR will increase for a liquor of uniform concentration if the boiling temperature is increased, i.e., boiling achieved at higher pressure. BPR causes a loss of T in each effect and is important in design calculations. The sum of the BPR values in individual effects (not bodies) is one of the variables used to calculate the overall ΔT for the evaporator set. However, BPR is not heat loss and is not considered a part of total losses in the system. Btu– Using the English system, the unit of heat is the Btu (British thermal unit). The Btu is the heat required to raise the temperature of one pound of water one degree Fahrenheit (at 60F). 1 Btu = 1.05506 kJ in SI units. Condensate terminology

Steam condensate – Condensate formed during condensing of low pressure steam supplied to the multiple effect evaporator, MEE.

Clean process condensate – Condensate that is collected from condensing vapors from black liquor other than

that from bodies where feed weak liquor vapor is condensed. Foul process condensate – Condensate that is collected from condensing vapors from feed weak black liquor or

from the surface condenser where a significant amount of the vapor chest vent gases from each vessel are condensed.

Delta T, (T) – The driving force causing heat transfer is the “temperature difference” or ΔT. The heating fluid must always be hotter than the heated fluid; the cooling fluid must always be colder than the fluid cooled. The ΔT provides the push, causing the heat (Btu’s) to flow towards the cooler fluid.

Page 15: Key Process Indicators-Falling Film Evaporators

15 / Recommended test procedure for black liquor evaporators TIP 0416-11

The ΔT of an individual evaporator body is the steam or vapor saturation temperature in the condensing side minus exiting liquor temperature in the liquor side of that body. This definition is by industry convention. The heat transfer process is actually governed by the log mean temperature difference. However, since the entering temperature is in many cases hard to define the noted convention is used. One exception is in forced circulation evaporators where the entering and exit temperatures from the heater unit can be measured. In this case the log mean temperature difference is used. The overall ΔT of an evaporator set is the saturated steam temperature minus the surface condenser vapor temperature minus the sum of the BPR values in individual effects. Effects and bodies – The vessels comprising the MEE are referred to either as effects or bodies. The number of bodies is the number of physically distinct vessels in the MEE. The number of effects is the number of vessels having distinctively different energy supply pressures. Example 1: An MEE has three vessels with steam being supplied to the first. Vapors from the remaining two vessels both flow to a common condenser. This MEE has 3 bodies and 2 effects. The first effect is the first body and the second effect consists of the two bodies 2 and 3 that are both supplied by first effect vapors. Example 2: An MEE has three vessels with steam being supplied to the first. Vapors from vessel 1 flow to vessel 2 and vapors from vessel 2 flow to vessel 3 and vapors from vessel 3 flow to a surface condenser. This MEE has 3 bodies and 3 effects Latent heat – Latent heat is the heat required or available in producing a phase change at constant pressure and constant temperature. If heat is added to ice at freezing temperature and atmospheric pressure, the ice will melt and the temperature will remain constant. The heat so utilized is the “latent heat of fusion.” If sensible heat is added to water sufficient to raise its temperature to 212ºF (100ºC) at atmospheric pressure, the water temperature suddenly becomes constant as additional latent heat of vaporization (LHV), is added causing the water to evaporate to steam. Latent heat is not lost but will become available or required whenever a substance passes through a phase change. Latent heat is expended (a) in overcoming the molecular cohesion of the constituents of a substance and (b) in overcoming the resistance of external pressure to a change of volume of the heated or cooled body. Latent heat of vaporization thus is composed of (a) internal and (b) external fractions. In evaporating 1 lb of water at 212ºF to 1 lb of steam at 212ºF, 897.6 Btu are expended as internal latent heat and 72.7 Btu as external latent heat for a total of 970.3 Btu. Latent heat of vaporization, LHV – This is the most important characteristic of a liquid in an evaporator. Latent heat is the prime source of heat available from the condensing steam and the prime heat requirement. Latent heat is the basis of multiple-effect evaporation since the latent heat in the vapor from one effect provides the necessary heat to cause the liquid in the next effect to boil, though at a lower temperature of course. Multiple effect evaporation, MEE – Evaporation of water from a process stream in two or more vessels wherein external energy (typically low pressure steam) is supplied to the first vessel. A heat transfer surface, typically tubes or plates, separates the condensing steam and the boiling liquor. Water vapor evaporated in the first vessel flows to the second vessel supplying energy for evaporation in this vessel. The second vessel is at a lower temperature and pressure than the first. Vapors from the second vessel flow either to a third vessel or to a condenser. Vapors from the third and subsequent vessels similarly cascade to the next effect and then to a condenser. Black liquor evaporators typically have from 5 to 8 effects, the number depending on desired economic return considering the cost of capital and operating cost of steam. Non-condensable gases, NCG – Gas components of vapor released during evaporation that do not condense at the lowest temperature and pressure the vapor can contact. For example, if the lowest contact temperature is 130ºF (54.4ºC), which corresponds to -25.4 in. Hg vacuum (15.3 kPa-a) water vapor pressure, then NCG are those components that remain as gases at this condition. Evaporator NCG typically include nitrogen, oxygen, hydrogen sulfide, methyl mercaptan, and dimethyl disulfide. NCG within evaporators will be saturated with water vapor, consistent with the process conditions. Personal Protection Equipment, PPE – Safety equipment to protect from personal injuries. PPE typical for work in evaporator areas include hard hat, eye protection, hearing protection, hand protection, steel-toe shoes, and others as defined by specific mill policies.

Page 16: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 16

Sensible heat – The heat utilized in raising the temperature of a fluid is termed “sensible heat.” In the case of water, the sensible heat required to raise it from 32ºF to the boiling point corresponding to the pressure at which steam is formed is also termed the “heat-of-the-liquid.” For example: The heat required to raise 10 pounds of water from 80ºF to 180ºF is 1 10 (180-80) = 1,000 Btu of “sensible heat.” Steam economy, SE – The unit mass of water that can be evaporated per unit mass of steam supplied to a multiple effect evaporator. Example: If the evaporation rate = 400,000 lb/h and total steam supplied = 90,000 lb/h, then the steam economy = 4.44 lb water evaporated / lb of steam supplied. Steam economy increases with an increasing number of effects in a multiple effect evaporator. Total heat, Q – Heat transfer in MEE systems is covered by one basic law: Q = U A T This states that Q, the total heat transferred in Btu/h or W, is equal to the product of the heat transfer coefficient, U times the heat transfer area, A, (ft2 or m2) times the available temperature difference, ΔT (ºF or ºC). The heat-balance determines the Q. The coefficient of ΔT heat-transfer U is determined, usually by actual test (or recorded data) or by calculation based on the physical characteristics of the liquid and the evaporator type. The U is a widely variable number ranging from nearly zero to several hundred Btu/h-ft2-F (0-3 kW/m2-K). The U is, therefore, the most significant part of the above formula but can be difficult to determine. For tubular evaporator, where evaporation occurs within the tubes, the area referred to in the above equation is the inside surface area. For evaporators of the lamella (plate) design or tubular units where evaporation takes place on the outside of the tube, the area term refers to the outside surface area.

Page 17: Key Process Indicators-Falling Film Evaporators

17 / Recommended test procedure for black liquor evaporators TIP 0416-11

Appendix B. Field data summary

SECTION 1: Field Measurements

Effect No.

Vapor Head Pressure (including flash tanks)

Steam/Vapor Chest Pressure

Feed Liquor Flow/Temp.

Product Liq. Flow/Temperature

Steam Flow

Surface Condenser Water Flow

Surface Cond. Water Temp. In./Out

SECTION II: Equipment Design Data

Effect No.

Heating Element Area

Internal Heater Area

External Heater Area

Vapor Head Diameter/St. Side

Vapor Pipe Inlet Diameter

Type Entrainment Separator

Condensate Segregation Yes/No

Soap Skimmer location between effect & ; Inlet temp. F Outlet temp. F

Liquor Flow Arrangement: Feed: % to ; % to ; & % to , then

SECTION III: Mill Data

Type Process; Kraft Other, Describe

Type Digester Batch Continuous

Type Furnish Softwood Hardwood Blend, Describe Wood Species;

SECTION IV: Equipment Performance Data

Boilout Frequency; Evaporator Concentrator

Type Scale; Describe

Operating Problems

Page 18: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 18

Appendix C. Laboratory analysis

SECTION V; Liquor Solids

Feed solids % Product solids %

Effect no.

Liquor out, %

SECTION VI; Liquor Analysis (Standard testing)

Carbonate Residual Alkali

Sulfate Residual Sulfide

Sodium Fiber

Potassium TAPPI Solids

Calcium

SECTION VII; Boiling Point Rise Data

Put BPR Curve Here

Page 19: Key Process Indicators-Falling Film Evaporators

19 / Recommended test procedure for black liquor evaporators TIP 0416-11

Appendix D. Specific gravity of black liquor

Page 20: Key Process Indicators-Falling Film Evaporators

TIP 0416-11 Recommended test procedure for black liquor evaporators / 20

Appendix E. Sampling black liquor for tall oil soap analysis

This appendix describes the procedure to be followed in collecting black liquor samples for tall oil soap analysis. Black liquor samples for tall oil soap analysis Phase separation of tall oil soap occurs very quickly in black liquor, therefore, a special procedure must be followed to obtain a representative sample that will permit accurate determination of tall oil content. The liquor sample must be diluted in water to approximately 5% solids concentration to assure that all of the tall oil will dissolve. This necessitates that liquor solids concentration at the sampling point be determined to an accuracy of about 2%. Next, calculate the quantity of water that would be required to produce a 500 mL volume of sample at approximately 5% solids, then proceed as follows: 1. Mark container to indicate 500 mL level. 2. Place the specified quantity of water in the sample container. 3. Flush the sample tap to assure that a representative sample can be obtained. 4. Add liquor to the container to the fill mark making sure that liquor enters water and does not contact

sides of container. 5. Cap the container and shake gently to assure tall oil is dissolved. 6. If container has a ground glass joint, do not use silicone grease or any type of lubricant. The formula for calculating the quantity of dilution water for a 500 mL sample is: 22.5 Dilution water = 500 - Liquor Solids The quantity of dilution water required for a 500 mL sample for various liquor solids concentrations is provided in the table below. Liquor Solids Dilution Water Liquor Solids Dilution Water (%) (mL) (%) (mL) 15 350 33 432 17 368 35 436 19 382 37 439 21 393 39 442 23 402 41 445 25 410 43 448 27 417 45 450 29 422 47 452 31 427 49 454