Kenneth Moore Architectural Engineering Lighting/Electrical September 8, 2014 University of Maryland Baltimore Health Sciences Facility III Tech Report 1, Part 1 Lighting Proposal Memo Circulation Space - Atrium Refer to A121E LEVEL ONE FLOOR PLAN EAST and A121W LEVEL ONE FLOOR PLAN WEST Room 1001: Lobby/Gathering Space The main atrium will be a suitable space to implement the psychological counterpart system of Spaciousness versus Closure. Since the atrium is 7 stories in height, it will be an interesting challenge to make such a large space seem a pleasing, ambient space. The seventh floor has a series of coves, which will need to be adequately lit to be visible from the ground floor, while not visible from an angle outside of the building . Outdoor Space + Building Façade Refer to L101 LANDSCAPE PLAN, L201 PLANTING DETAILS & NOTES, L202 GREEN ROOF PLANTING PLAN, L203 GREEN ROOF PLANTING PLAN I plan to use the majority of the outdoor space in my lighting design. There are multiple green roofs that can be seen in the planting plans. The majority of the site lighting will have to be integrated into the landscaping, some of which will need to showcase the façade of the building. There is also a large overhang space under the dry lab tower. This will require recessed outdoor lighting fixtures to be integrated into the first story ceiling. Large Work Space Refer to A121E LEVEL ONE FLOOR PLAN EAST and A121W LEVEL ONE FLOOR PLAN WEST Rooms 1140 and 1130: Nanomedicine PDoc/GS/TECH Workstation The large work space on the first floor is predominantly a workstation space. I will conduct lighting studies of the most appropriate design applicable to the desk height and intended layout. This will most likely result in evenly spaced recessed troffers or equally spaced pendant fixtures. Special Purpose Space Large Conference Room Refer to A121E LEVEL ONE FLOOR PLAN EAST Room 1010: Meeting Room There are many conference rooms in this section of the building, however this one is located on the first floor with the majority of the room consisting of curtain walls. This means that the

Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

Kenneth Moore

Architectural Engineering – Lighting/Electrical

September 8, 2014

University of Maryland – Baltimore

Health Sciences Facility III

Tech Report 1, Part 1 Lighting Proposal Memo

Circulation Space - Atrium Refer to A121E LEVEL ONE FLOOR PLAN EAST and A121W LEVEL ONE FLOOR PLAN WEST

Room 1001: Lobby/Gathering Space

The main atrium will be a suitable space to implement the psychological counterpart system of

Spaciousness versus Closure. Since the atrium is 7 stories in height, it will be an interesting

challenge to make such a large space seem a pleasing, ambient space. The seventh floor has a

series of coves, which will need to be adequately lit to be visible from the ground floor, while not

visible from an angle outside of the building .

Outdoor Space + Building Façade Refer to L101 LANDSCAPE PLAN, L201 PLANTING DETAILS & NOTES, L202 GREEN ROOF PLANTING PLAN, L203

GREEN ROOF PLANTING PLAN

I plan to use the majority of the outdoor space in my lighting design. There are multiple green

roofs that can be seen in the planting plans. The majority of the site lighting will have to be

integrated into the landscaping, some of which will need to showcase the façade of the building.

There is also a large overhang space under the dry lab tower. This will require recessed outdoor

lighting fixtures to be integrated into the first story ceiling.

Large Work Space Refer to A121E LEVEL ONE FLOOR PLAN EAST and A121W LEVEL ONE FLOOR PLAN WEST

Rooms 1140 and 1130: Nanomedicine PDoc/GS/TECH Workstation

The large work space on the first floor is predominantly a workstation space. I will conduct

lighting studies of the most appropriate design applicable to the desk height and intended layout.

This will most likely result in evenly spaced recessed troffers or equally spaced pendant fixtures.

Special Purpose Space – Large Conference Room Refer to A121E LEVEL ONE FLOOR PLAN EAST

Room 1010: Meeting Room

There are many conference rooms in this section of the building, however this one is located on

the first floor with the majority of the room consisting of curtain walls. This means that the

Page 2: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

lighting design of the outdoor space must not interfere with the conference room lighting, and

vice versa. This will be an important study in reducing glare and maximizing daylighting

potential. The large conference room will be a suitable space for the three schematic design

concepts. I would like to integrate this room into the surrounding landscape of the outdoor space

which can be seen upon entering the space from the elevator lobby. My initial thoughts include

cove lighting in the conference room ceiling and around the north wall of the room.

Page 3: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

UPUP

REF

.

UPUP

UPUP

1

H

G

B

C

E

F

A

1A301

1A305

2

B1

D

7643 54.5 5.5

E.5

21' - 0"

H.2

7A442

1A446

4A317

1A320

A207

1

2

3 4

1.5

4A405

3A401

CL103

1S01B

1S01

SH103

/MA TCHLINE SEE:

1A12 1E

2J6

2A6A

2A6A

2J6

2J6

2J6

0A6

0H6

0H6

1A6

0H6

1A6

1A6

2J6

2J6

2J6

2J6

5A207

6A207

3' - 11 5/8" 5' - 10 3/8" 5' - 3 5/8" 15' - 8 3/8" 5' - 3 5/8" 15' - 8 3/8" 5' - 3 5/8" 15' - 8 3/8" 5' - 3 5/8" 15' - 8 3/8" 5' - 3 5/8" 15' - 8 3/8"

2' - 0"

7' - 2

"5'

- 4 3/

8"22

' - 7 5

/8"5'

- 4 3/

8"15

' - 11

5/8"

5' - 4

3/8"

20' -

0 3/4"

6' - 2

7/8"

5' - 4

3/8"

20' -

0"

2A356

4A356

6A356

1A356

2A359

1A357

EL. 70' - 0"

CL104

2.5

31' -

6"

5A356

2A357

3A356

1A359

1101A1 1101A2 1101A3

1101A4 1101A5 1101A6

TW1 EW1

1A502

1A503

1175A

1101B4 1101B3

1101B2

1A336

1A337

10'-6" 2'-9" 5'-0" 2'-9" 21'-0" 2'-9" 5'-0" 2'-9" 10'-6" 21'-0" 2'-9" 5'-0" 2'-9"

3'-7" 6'-5 1/4" 14'-7 1/8" 25'-0" 17'-0 1/8" 10'-5 1/2" 10'-6 1/2" 10'-6" 10'-6"

10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6"

9'-3"

10'-6

1/8"

10'-6

1/8"

9'-5 1

/2"2'-

5 7/8"

15'-3

1/2"

5'-11

5/8"

7'-11

5/8"

1'-3 3

/4"7'-

3 3/4"

2'-1 1

/4"

6'-4 1

/4"5'-

7 1/8"

4'-0 3

/4"21

'-10 1

/8"11

'-11 3

/8"10

'-0 1/

8"

21'-1

0 1/8"

2'-6 1

/8"8'-

6 3/8"

9'-1 1

/4"12

'-5"

1'-11

1/8"

18'-2

5/8"

11'-5

1/2"

11 1/

2"

3'-9 3/8" 7'-10 3/8" 8'-7 7/8" 3'-7 3/4" 6'-10 1/4" 10'-6"

Stair 11S01 Shaft

SH101IT Room

TW1Electrical Room

EW1

ShaftSH103

Vestibule1101B

Vestibule1101A

Lobby/GatheringSpace

1001

Lobby1001

Stair 41S04

BAS ClosetCL103

SCCL104

2J6

2J6

2J6

2J6

2A6A

2A6A

2A6AA

2J6

2A6A

1A6

2J6

2J6

1A6

2J6

0H2

0A3

0A30G2

0A3

0H2 0H2

0H2

3'-2 3/4" 7'-9 1/4" 9'-5 1/4"

2J6

0D3 0D

3

0D3

0D3

0D3

0D3

0D3

0D6

0D3

2J6

0D6

0D6

0D60D6

0D3

0G3

0D6

1A3B

0D3B

0D3B

0D3B

0D3B

0D3B

0D3B

0D3B

0D3B

0D3A

1A3A 1A3A

0H8

0D3

0D6

0D3

0D3

0H2

0H2

1A6

0H2

0D6 0D6

0H80H80H80H8

0G6

WLA1165

Office1181

Office1180

Office1177

Office1176

LER1160

Fire CommandCenter

1171

Lab Support1142

CorridorC112

Microscopy1141

Lab Support1131

Office1173

ShaftSH109

Clean Room1164

Lab Support1161

Lounge/StaffLunch Rm

1175

Lab Support1151

Lab Support1152

Lab Support1150

Lab Support1144

PhysiochemicalCharacterization

1145

NanomedicinePDoc/GS/Tech

Wkst1140

SAIR Suite1132

CTR1167

Autoclave1166

Clean Room1162

Clean Room1163

CTR1143

1151

1152

1176 1177 1178 1179

1145 1142

1132

1165

1141B

1175

1180 1181

1161

117411731172

1141A

1134A

11621162A

1163

2'-9" 5'-0" 2'-9"2'-9" 5'-0" 2'-9" 2'-9" 5'-0" 2'-9"

8A405

1S04A

1S04B

Office1172

Office1174

Office1178

Office1179

2J6

NanomedicinePDoc/GS/Tech

Wkst1130

1171A

1171B

3

3

3

3A343

1A729

5A343

1A343

A207A

1

FEC FEC FEC

FECFECFEC

FEC FEC

FEC

0D3

?

1S01A

1. WHERE INDICATED ON THESE PLANS,LABORATORY CASEWORK AND FURNITURE ARESHOWN FOR REFERENCE ONLY. SEE THE LABFURNISHING PLANS AND FURNITURE PLANS FORLAYOUTS, DIMENSIONS, DETAIL KEYS AND OTHERINFORMATION.

2. REFER TO SHEET A519 FOR DETAILS AT TYPICALINTERIOR COLUMNS NOT INCLUDED IN ENLARGEDPLAN DETAILS.

3. REFER TO SHEET A540 FOR DETAILS AT WALLBASES AND THRESHOLDS.

4. REFER TO ENLARGED FURNITURE PLANS A800LBATO A816 FOR LOCATIONS OF FLOOR BOXES.

5. REFER TO SHEETS A160LB THROUGH A171 FORFINISH PLANS THAT COORDINATE WITH FINISHSCHEDULE.

6. PROVIDE ELECTROMAGNETIC AND/OR LEADSHIELDING AS REQUIRED BY THE PROJECTSPECIFICATIONS.

7. REFER TO THE SPECIFICATIONS FOR FIREEXTINGUISHER REQUIREMENTS IN BACK OF HOUSEAREAS.

EAST/WEST FLOOR PLAN NOTES

ADMINISTRATION & FINANCE

FACILITIES MANAGMENTARCHITECTURE, ENGINEERING &CONSTRUCTION DIVISION220 ARCH STREET, OFFICE LEVEL 3BALTIMORE, MARYLAND 21201

PHONE NO. (410) 706-7740FAX NO. (410) 706-8547

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410)706-6882UMB WORK CONTROL (410)706-7570

KEY PLAN

A/E CONSULTANTS

PROFESSIONAL CERTIFICATION. I HERE BY CERTIFY THAT THESEDOCUMENTS WERE PREPARED OR APPROVED BY ME, AND THATI AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THELAWS OF THE STATE OF MARYLAND,

LICENSE No.

EXPIRATION DATE: .

,

REGISTRATION / STAMP

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DATE:

CAD FILE NO.:

A/E PROJECT NO.:UMB PROJECT NO.:

UMB BUILDING NO.:

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20850

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

EASTWEST

HSF III

11-38512.14006.00

HEALTHSCIENCESFACILITY III

DONOR NAME.:

A121W

LEVEL ONEFLOOR PLAN -WEST

07/25/2014

1/8" = 1'-0"1 FLOOR PLAN - LEVEL 01 WEST

Revisions

No. Date Item1 05/08/14 Addendum 42 6/13/14 Bulletin 93 7/25/14 Bulletin 10

B CA B CA B CA B CA

Main Index

Arch Index

Curb per 1/A365RFI 24 Item 13j

GO TO ARCH GO TO HVAC GO TO HVAC PIPING GO TO PLUMB GO TO ELEC FP SUBMITTALS

Page 4: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

UPUP

UP

UP

UPUP

DN

H

G

B

C

E

F

A

7.5

1A305

B1

2A202

1A306

D

76 12111098 11.5

1A302

1A303

EE

E.5

105

104

103

101

102

AA

BB

CC

DD

2' - 8 5/8"

17' - 7 1/4"

17' - 3"

16' - 11 1/2"

11' - 5 3/4"

2' - 8 5/8"

9' - 3"

10' - 11"

12' - 6 1/8"

1A202

3A202

H.2

1A431

10A431

7A431

1A446

A440

2

A440

6

A440

3

2A443

A444 3

A447 11A44712

1A550

7A447

1A447

1A310

1A311

1A313

1A315

1A316

3A316

1A318

2A328

3A328

4A328

5A328

1A331

2A333

2A208

1A410

1A408

3A405

3A403

12A405

103.1

104.8

BB.1

COMPACTOR

DOCK LIFTC104

1115

1154

1S03

EE1

1164

TE1

1105

1104

1154A

1S02A

C103

1S03A

CL103

SH103

/MATCHLINE SEE:

1A121W

2J6

2J6

1A6AP

1M8

1A6

0M8U

0M8

0M8U

1M8R

0M8R

2M8R

2M6

0M6

1M8

1M6

2M6

1A208

WHEELCHAIRLIFT

15' - 8 3/8" 16' - 6" 30' - 1" 15' - 4" 16' - 0 3/8" 9' - 11 5/8" 22' - 0 3/8" 2' - 11 5/8" 2' - 0" 13' - 9"

21' - 0" 15' - 8 3/8" 2' - 8"1' - 8" 14' - 1" 44' - 10" 15' - 8 3/8" 5' - 3 5/8" 5' - 4 3/8" 4' - 3 5/8"

7' - 1 1/2"

17' - 2 3/8"

5' - 3

5/8"

21' -

0 3/8"

5' - 4

"0"

5' - 3

5/8"

16' -

0 3/8"

5' - 3

5/8"

19' -

4 3/8"

3' - 4

"5'

- 3 5/

8"7'

- 2 3/

4"

4A358

3A358

SLOPE 1/8" PER FT. SLOPE 1/8" PER FT.

SLO

PE

1/8"

PER

FT.

SLO

PE

1/8"

PER

FT.

SLOPE 1/8"PER FT.

SLOPE 1/8"PER FT.

SLO

PE

1/8"

PER

FT.

SLO

PE

1/8"

PER

FT.

SLO

PE

1/8"

PER

FT.

SLO

PE

1/8"

PER

FT.

SLOPE 1/8"PER FT.

SLOPE 1/8"PER FT.

SLO

PE

1/8"

PER

FT.

SLO

PE

1/8"

PER

FT.

SLOPE 1/8"PER FT. FD

FD

FD

FD

FD

FD

FD

FD

FD

FD

4A357

2A358

6A357

5A357

EL. 70' - 0"

EL. 69' - 10"

EL. 69' - 10"

EL. 65' - 6"

EL. 65' - 6"

EL. 65' - 6"

EL. 65' - 6"

EL. 69' - 10"

EL. 70' - 0"

EL. 70' - 0"

EL. 70' - 0"

EL. 70' - 0"

BOLLARD, TYP.

8' - 6

"

7' - 5" 2' - 1"

1' - 6

"1'

- 6"

1' - 8 5/8"

1' - 0"

2' - 0"

61' - 5 7/8"

61' - 5 3/8"

61' - 6"

61' - 4 3/4"

61' - 3 3/4"

61' - 6"

61' - 3 3/4"

61' - 5 7/8"

PAPE

R / P

LAST

IC+G

LASS

/ CAR

DBOA

RD / C

OMPO

ST

1A352

2A352

1A730

2A357

3A357

1A358

5A358

6A358

1A359

1120

1A731

3A731

C102

1154B

1117

1S02

4A731

6A731

1M8U

R

1M8U

1M8U

0M8U

1M8U

3'-8 1/2"

3'-8 1

/8"

3'-6 7/8"

3'-6 7/8"

5A726

7'-5 5/8" 5'-1 5/8" 9'-0 1/8" 18'-1 5/8" 2'-11" 30'-10"

2'-9" 5'-0" 2'-9" 32'-5 1/2" 8'-7 1/4"

10'-6" 10'-6" 17'-11 1/2"

10'-6" 29'-3 1/4" 2'-2 3/4"

17'-0 1/8"

5'-10"

5'-7 5/8"

3'-7 1/2"

7'-3 3/4"

2'-5 3/8"

31'-7 7/8"

2'-1 1/4"7'-10 3/4"

2'-7 1/4"

11'-7

"8'-

7"10

"31

'-6"

13'-8

3/8"

3'-7 5

/8"17

'-4 3/

8"11

1/2"

20'-2

1/4"

9'-7 1

/4"

2'-6 1

/8"12

'-5"

1'-11

1/8"

18'-2

5/8"

11'-5

1/2"

11 1/

2"

6'-1 3

/4"1'-

2"3'-

3 5/8"

29'-7

3/8"

7'-2 7

/8"2'-

4"10

'-0 1/

8"9'-

5 5/8"

4'-4 1

/4"

9'-10

"

5'-5 1/4"

8'-10 3/4" 6'-7" 20'-4" 5'-5 3/8"

3'-2"

ShaftSH107

ShaftSH108

Loading/Staging/Recycling1111

Biohazard WasteStorage

1104

Animal Receiving1115

Water Pump1120

CorridorC104

CorridorC105

Stair 31S03

Lobby/GatheringSpace

1001

ElevatorPE107

ElevatorSE101

Elevator LobbyC106

IT RoomTE1

Electrical RoomEE1

JC1117

CorridorC103

BAS ClosetCL103

Cylinder Stor1106

Chemical WasteStorage

1105

Stair 51S05

2J6

2J6

2J6

2J6

2A6A

2A6A

2A6A

2A6A

2J6A

2J6

ElevatorPE103

ElevatorPE104

ElevatorPE105

ElevatorPE106

ElevatorSE102

2J6

2J6

2J6

2J6

0A6A

P

0A3AP

2J6

2J6

1M8

0M6

0A6

0A6AP

0A6AP

1A6

0A6

2A6A 0H2

0H2

1M6

0M6

2J6

2J6

0H2

0G3P

0H3

0H21M

8

0H3

2A6A

0A3

0H2

0H2

2J6A

2J6A0H

3

2M8

3'-11 1/4" 1'-9 3/8"

2A6A

0A6A

P

0A6AP

1A6A

1182

0M8U

0M8

0M8U

0M8

Stair 21S02

0A3

0G20A3

9'-5 1/4"

11' - 1 3/4"

7' - 7 1/4"

24' - 7 1/4"

10' - 8 1/8"

2J6

0H3

0H3

0G3P

2J6

TRUCK RESTRAINT

TRUCK BUMPERS

TRUCK RESTRAINT

TRUCK BUMPERS

1A732

2A6A

1M8U

1A6

0D60D6

1A6A

0D6

0D3B

0D3B

0D3A

0H8

0D3A

0D3

1A6

0A6A

0H2

0H2

10' -

8 3/4"

DIRTY BEDDINGDUMPSTER

DIRTY BEDDINGVACUUMSYSTEM

EQUIPMENT

6' - 0"

CYLINDER STOR.

CorridorC102

Vestibule1125

Office1181

Office1180

Meeting Rm1010

Bioinformatics1134

CorridorC110

CorridorC111

Microscopy1141

Lab Support1131

(Wet Lab) LargeConference Rm

1182

SAIR Suite1132

CTR1167

Storage1010A

ShaftSH110

MenLocker/Shower

1118

WomenLocker/Shower

1119

Men1101

Women1100

Restroom1102

Wellness Rm1103

Elevator Lobby1003

ShaftSH113

CorridorC109

CorridorC101

EMR1164

C110

1104

1179

1132

1180

1133

1181

C111

1010A1

1010A2

1134A

1134

1104A

1119A

1118A

1119

1118

1101

1100

1103 1102

1125

C101

1105A 1105C1105B

SS STANCHION

3

7' - 6

"31

' - 6"

31' -

6"11

' - 7"

9' - 5

"31

' - 6"

21' -

0"20

' - 3"

8' - 2

"11

' - 7"

2'-9" 5'-0" 2'-9" 28'-5 1/2" 4'-1 1/2"

1A6A

0H2

2J6

1154D1154C

NanomedicinePDoc/GS/Tech

Wkst1130

4'-5 5

/8"5'-

6 7/8"

1'-2" 2'-0"MANF.PER 2'-0"

24" WIDE EMBEDDEDSTEEL SKID PLATES

5

1A411

1A729

5A343

1A343

FEC

FEC

FEC

FEC

FEC

FEC

1M6 2M8U

1120A

23'-6 1/2" 3'-5 5/8" 6'-7"9'-1 3

/4"

CLR.8'-0"

1. WHERE INDICATED ON THESE PLANS,LABORATORY CASEWORK AND FURNITURE ARESHOWN FOR REFERENCE ONLY. SEE THE LABFURNISHING PLANS AND FURNITURE PLANS FORLAYOUTS, DIMENSIONS, DETAIL KEYS AND OTHERINFORMATION.

2. REFER TO SHEET A519 FOR DETAILS AT TYPICALINTERIOR COLUMNS NOT INCLUDED IN ENLARGEDPLAN DETAILS.

3. REFER TO SHEET A540 FOR DETAILS AT WALLBASES AND THRESHOLDS.

4. REFER TO ENLARGED FURNITURE PLANS A800LBATO A816 FOR LOCATIONS OF FLOOR BOXES.

5. REFER TO SHEETS A160LB THROUGH A171 FORFINISH PLANS THAT COORDINATE WITH FINISHSCHEDULE.

6. PROVIDE ELECTROMAGNETIC AND/OR LEADSHIELDING AS REQUIRED BY THE PROJECTSPECIFICATIONS.

7. REFER TO THE SPECIFICATIONS FOR FIREEXTINGUISHER REQUIREMENTS IN BACK OF HOUSEAREAS.

EAST/WEST FLOOR PLAN NOTES

ADMINISTRATION & FINANCE

FACILITIES MANAGMENTARCHITECTURE, ENGINEERING &CONSTRUCTION DIVISION220 ARCH STREET, OFFICE LEVEL 3BALTIMORE, MARYLAND 21201

PHONE NO. (410) 706-7740FAX NO. (410) 706-8547

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410)706-6882UMB WORK CONTROL (410)706-7570

KEY PLAN

A/E CONSULTANTS

PROFESSIONAL CERTIFICATION. I HERE BY CERTIFY THAT THESEDOCUMENTS WERE PREPARED OR APPROVED BY ME, AND THATI AM A DULY LICENSED PROFESSIONAL ENGINEER UNDER THELAWS OF THE STATE OF MARYLAND,

LICENSE No.

EXPIRATION DATE: .

,

REGISTRATION / STAMP

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DATE:

CAD FILE NO.:

A/E PROJECT NO.:UMB PROJECT NO.:

UMB BUILDING NO.:

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20850

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

EASTWEST

HSF III

11-38512.14006.00

HEALTHSCIENCESFACILITY III

DONOR NAME.:

A121E

LEVEL ONEFLOOR PLAN -EAST

07/25/2014

1/8" = 1'-0"1 FLOOR PLAN - LEVEL 01 EAST

Revisions

No. Date Item1 04/18/14 Addendum 32 05/08/14 Addendum 43 6/13/14 Bulletin 94 6/13/14 Addendum 55 7/25/14 Bulletin 10

B CAB CAB CAB CA

Main Index

Arch Index

GO TO ARCH GO TO HVAC GO TO HVAC PIPING GO TO PLUMB GO TO ELEC FP SUBMITTALS

Bollards are 8" dia., expansionanchor, concrete filledBP5 Pre-Bid Structure RFI 2

CIP Stair- see 2/S306BP5 Pre-Bid Structure RFI 3

Page 5: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20852

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

HEALTH

SCIENCES

FACILITY III

SHEET TITLE :

PROJECT TITLE :

REVISIONSITEMDATENO

REGISTRATION / STAMP

A/E CONSULTANTS

UMB PROJECT NO. :

DATE :

SRI PROJECT NO. :

UMB BUILDING NO. :

SHEET NO.

CAD FILE NO. :

ADMINISTRATION & FINANCE

220 ARCH STREET, OFFICE LEVEL 3

PHONE NO. (410) 706-7740

BALTIMORE, MARYLAND 21201

FAX NO. (410) 706-8547

FACILITIES MANAGEMENT

CONSTRUCTION DIVISIONARCHITECTURE, ENGINEERING &

KEY PLAN

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410) 706-6882UMB WORK CONTROL (410) 706-7570

DONOR NAME :

LANDSCAPE

PLAN

L101

Main Index

Land Index

Page 6: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20852

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

HEALTH

SCIENCES

FACILITY III

SHEET TITLE :

PROJECT TITLE :

REVISIONSITEMDATENO

REGISTRATION / STAMP

A/E CONSULTANTS

UMB PROJECT NO. :

DATE :

SRI PROJECT NO. :

UMB BUILDING NO. :

SHEET NO.

CAD FILE NO. :

ADMINISTRATION & FINANCE

220 ARCH STREET, OFFICE LEVEL 3

PHONE NO. (410) 706-7740

BALTIMORE, MARYLAND 21201

FAX NO. (410) 706-8547

FACILITIES MANAGEMENT

CONSTRUCTION DIVISIONARCHITECTURE, ENGINEERING &

KEY PLAN

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410) 706-6882UMB WORK CONTROL (410) 706-7570

DONOR NAME :

PLANTING

DETAILS &

NOTES

L201

Main Index

Land Index

Page 7: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20852

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

HEALTH

SCIENCES

FACILITY III

SHEET TITLE :

PROJECT TITLE :

REVISIONSITEMDATENO

REGISTRATION / STAMP

A/E CONSULTANTS

UMB PROJECT NO. :

DATE :

SRI PROJECT NO. :

UMB BUILDING NO. :

SHEET NO.

CAD FILE NO. :

ADMINISTRATION & FINANCE

220 ARCH STREET, OFFICE LEVEL 3

PHONE NO. (410) 706-7740

BALTIMORE, MARYLAND 21201

FAX NO. (410) 706-8547

FACILITIES MANAGEMENT

CONSTRUCTION DIVISIONARCHITECTURE, ENGINEERING &

KEY PLAN

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410) 706-6882UMB WORK CONTROL (410) 706-7570

DONOR NAME :

GREEN ROOF

PLANTING

PLAN

L202

Main Index

Land Index

Page 8: Kenneth Moore Architectural Engineering Lighting ... · Lab Planning 303 South Broadway, Suite G20 Tarrytown, NY 10591 Melville Thomas Architects, Inc Interior Architects 600 Wyndhurst

HOKArchitect3223 Grace Street, NWWashington, DC 20007

Design CollectiveAssociate Architect601 East Pratt Street, Suite 300Baltimore, MD 21202

AEI EngineersME Engineers401 N. Washington St, Suite 400Rockville, MD 20852

WFT EngineersPlumbing/FA/FP Engineers9737 Washingtonian Blvd. Suite 588Gaithersburg, MD 20878

Cagley & AssociatesStructural Engineer6141 Executive Blvd,Rockville, MD 20852

Site ResourcesCivil Engineer / Landscape Architect14315 Jarrettsville Pike,Phoenix, MD 21131-0249

Jacobs ConsultancyLab Planning303 South Broadway, Suite G20Tarrytown, NY 10591

Melville Thomas Architects, IncInterior Architects600 Wyndhurst Ave. Suite 315Baltimore, MD 21210

HEALTH

SCIENCES

FACILITY III

SHEET TITLE :

PROJECT TITLE :

REVISIONSITEMDATENO

REGISTRATION / STAMP

A/E CONSULTANTS

UMB PROJECT NO. :

DATE :

SRI PROJECT NO. :

UMB BUILDING NO. :

SHEET NO.

CAD FILE NO. :

ADMINISTRATION & FINANCE

220 ARCH STREET, OFFICE LEVEL 3

PHONE NO. (410) 706-7740

BALTIMORE, MARYLAND 21201

FAX NO. (410) 706-8547

FACILITIES MANAGEMENT

CONSTRUCTION DIVISIONARCHITECTURE, ENGINEERING &

KEY PLAN

UMB EMERGENCY PHONE NUMBERS

UMB POLICE (410) 706-6882UMB WORK CONTROL (410) 706-7570

DONOR NAME :

GREEN ROOF

PLANTING

PLAN & NOTES

L203