36
EN4416DE20EN © 2004 Siemens AG 1 Solutions Siemens Solutions 1 optiPoint 410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Mobile HFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 BPOOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 4 Extended features for the Keysystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5 Alternative Routing on Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 6 Call Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 7 Edit Dial and Callog control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 8 UW7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 9 HiPath Backup&Restore (HBR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 10 CODEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Embed Size (px)

Citation preview

Page 1: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

Solutions

1 optiPoint 410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Mobile HFA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 BPOOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Extended features for the Keysystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 Alternative Routing on Error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 Call Forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 Edit Dial and Callog control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278 UW7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 HiPath Backup&Restore (HBR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3110 CODEW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

EN4416DE20EN© 2004 Siemens AG

1

Page 2: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

2

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 3: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

1 optiPoint 410

Install optiPoints 410 to a STMI2 board.

The connection between the optiPoints and the STMI2 should use voice compression.

Make a call and control, if a Codec with voice compression is used with the tools, you find on the PC.

Solution:

ADD-BCSU:MTYPE=PER,LTG=1,LTU=2,SLOT=43,PARTNO="Q2316-X ",FCTID=3;

ADD-HFAB:MTYPE=STMIHFA2,LTU=2,SLOT=43,SMODE=NORMAL,IPADDR=1.30.11.40, NETMASK=255.255.255.0,DEFRT=1.30.11.254;

RESTART-BSSU:ADDRTYPE=PEN,LTG=1,LTU=2,SLOT=43;

ADD-SBCSU:STNO=7188,OPT=OPTI,CONN=IP2,DVCFIG=OPTIIP,COS1=33,COS2=30, LCOSV1=9,LCOSV2=1,LCOSD1=9,LCOSD2=1,DPLN=0,ITR=0,STD=100;

ADD-SBCSU:STNO=7189,OPT=OPTI,CONN=IP2,DVCFIG=OPTIIP,COS1=33,COS2=30, LCOSV1=9,LCOSV2=1,LCOSD1=9,LCOSD2=1,DPLN=0,ITR=0,STD=100;

CHANGE-HFAB:MTYPE=STMIHFA2,LTU=2,SLOT=43,TYPE=ASC,CODECLST=G723;

● Set the Codec in the Configuration menu of the terminal:

– At the terminal: . Press the keys 1 0 3 simultaneously to get access to the “Configura-tion Menu” to change there the “Audio Settings”.

or

– Change the “Audio Settings” via the phone homepage with the following entry in the WEB Browser:

http://<ip address>:8082

● To see the used Codecs, start the homepage of the STMI2 board. To get access to the homepage of the STMI2 enter the following AMO command:

CHANGE-HFAB:MTYPE=STMIHFA2,LTU=2,SLOT=43,TYPE=DEBUG,FACCMODE=1;

EN4416DE20EN© 2004 Siemens AG

3

Page 4: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

4

ÜbungsaufgabenSiemens

a) When you are using the STMI2 homepage select the “dspSub” Menu -> “dspListActi-veChannels". All active calls are displayed. Note the B-channel. Return to the “dspSub” Menu enter the channel number under "show channel configuration". Now the channel configuration is displayed with the used Codec.

b) Also possible is to use the tool “Etherreal”, if a HUB is used or there are monitoring ports at the Layer 2 switch.

EN4416DE20EN© 2004 Siemens AG

Page 5: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

2 Mobile HFA

1. Add the feature Mobile HFA in your system.

Solution:

a) Which central AMO parameters are necessary for the function ?

ADD-WABE:CD=*50,DAR=MHFALGON,CD2=#50;

CHANGE-FEASU:TYPE=A,CM=MOBHFA;

REGENARATE-PERSI:TYPE=COPIN; */ Checking if COPIN1 = Mobile

DISPLAY-PERSI:TYPE=SYS; */ Checkking the length of PIN1

b) Which settings for the subscribers are necessary ?

ADD-PERSI:TYPE=STN,STNO=7288,PIN1=7288;

ADD-PERSI:TYPE=STN,STNO=7289,PIN1=7289;

CHANGE-SDAT:STNO=7288,TYPE=ATTRIBUT,AATTR=MHFAHOME&MHFATBV;

CHANGE-SDAT:STNO=7289,TYPE=ATTRIBUT,AATTR=MHFAHOME&MHFATBV;

c) How is the handling on the terminal ?

– Handling at the terminal:

*50 7288# 7288#

or

Service Menu --> mobility LogOn "ok" ---> 7288# --> 7288#

2. Add the feature network wide.

Add a Secretary-Executive group on the otipoints 410. Use all special keys for the Secre-tary and for the Executive.

EN4416DE20EN© 2004 Siemens AG

5

Page 6: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

6

SolutionsSiemens

a) Is it possible to use the Secretary-Executive feature with Mobile HFA ?

b) Can the DSS (Direct Station Selection) be used ?

Solution:

CHANGE-SBCSU:STNO=7289,OPT=OPTI,SECR=Y;

ADD-CHESE:EXEC=7288,SECR=7189,ALLOC=E1S1;

CHANGE-TAPRO:STNO=7289,KY09=DSS,KY10=PUS,KY11=RNGXFER;

CHANGE-TAPRO:STNO=7288,KY09=DSS,KY10=RNGXFER;

ADD-ZIEL:TYPE=DSS,SRCNO=7289,KYNO=9,DESTNOD=7288;

ADD-ZIEL:TYPE=DSS,SRCNO=7288,KYNO=9,DESTNOD=7289;

3. Add the ATND-DAR for destination of a “to be visited” phone !

Solution:

ADD-ZIEL:TYPE=FWD,SRCNO=7289,SI=VCE,DESTNOF=92,NAME=HFA,DTYPE=CFNR,I TYPE=GEN,CFVAR=SYSTEM;

4. Activate and deactivate the feature with the HiPath 4000 Assistant !

Configuration Management --> System Data--> Maintenance --> Maintenance HFA mobile

Remark: All Executive and Secritary functions can be used when using the feature HFA Mobile.

EN4416DE20EN© 2004 Siemens AG

Page 7: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

EN4416DE20EN© 2004 Siemens AG

7

Page 8: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

8

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 9: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

3 BPOOL

1. Add a Standby board for the HFA board, already installed.

a) using the HiPath 4000 Assistant

● Add the Standby board:

– Start HiPath 4000 Assistant

– Select menu “Configuration Management”

– Change to “System Data” -> “Board” -> “Board”

EN4416DE20EN© 2004 Siemens AG

9

Page 10: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

10

SolutionsSiemens

– Configure the HFA Standby BOARD DATA.

– Add the board

EN4416DE20EN© 2004 Siemens AG

Page 11: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

– Add the board pool:

– Select “Board Pool”

– Select “NEW”

EN4416DE20EN© 2004 Siemens AG

11

Page 12: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

12

SolutionsSiemens

b) Using AMO

– Existing board:

ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=91,PARTNO="Q2316-X ",FCTID=3;

– Existing HFA generating:

ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=91,SMODE=NORMAL,IPADDR=1.30.21.40, NETMASK=255.255.255.0,PATTERN=213,VLAN=NO,DEFRT=1.30.21.254,TCPP=4060, BITRATE="100MBFD",VLANID=0;

– Adding the Standby board:

ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3;

– Configuring the HFA Standby board data

ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

– Adding the board pool:

ADD-BPOOL:MTYPE=STMIHFA2,POOLNO=1,LTU=1,SLOT=91,HOPAUT=SINGLE or MULTI;

ADD-BPOOL:MTYPE=STMIHFA2,POOLNO=1,LTU=1,SLOT=61,HOPAUT=SINGLE or MULTI;

EN4416DE20EN© 2004 Siemens AG

Page 13: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

– Display the Board Pool:

DISPLAY-BPOOL;

H500: AMO BPOOL STARTED

+------------------------------------------------------------------------------+

| POOLNO = 1 MTYPE = STMIHFA2 HOPAUT = SINGLE |

| INFO = |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 91 HOP-AUT-CNT = 0 HOP-MAN-CNT = 0 |

| DC-STATUS = READY LAN-CONN = READY SMODE = NORMAL |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 61 HOP-AUT-CNT = 0 HOP-MAN-CNT = 0 |

| DC-STATUS = READY LAN-CONN = READY SMODE = STBYRDY |

+------------------------------------------------------------------------------+

2. Test the fuctionality by unplugging the LAN connection.

DISPLAY-BPOOL;

H500: AMO BPOOL STARTED

+------------------------------------------------------------------------------+

| POOLNO = 1 MTYPE = STMIHFA2 HOPAUT = SINGLE |

| INFO = |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 91 HOP-AUT-CNT = 0 HOP-MAN-CNT = 0 |

| DC-STATUS = DEF LAN-CONN = SMODE = STBYDEF |

| SWITCHED AUTTO BRD LTU = 2 SLOT = 91 DATE/TIME : 2004-04-10 18:07 |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 61 HOP-AUT-CNT = 1 HOP-MAN-CNT = 0 |

| DC-STATUS = READY LAN-CONN = READY SMODE = NORMAL |

| SWITCHED AUTFR BRD LTU = 2 SLOT = 25 DATE/TIME : 2004-04-10 18:07 |

+------------------------------------------------------------------------------+

EN4416DE20EN© 2004 Siemens AG

13

Page 14: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

14

SolutionsSiemens

3. Set the “Standby defect” board to the state "Standby ready"

a) using the HiPath 4000 Assistant

– Start the “Configuration Management”

– Select “Maintenance” -> “Board Maintenace”

– Search boards

– Change to “object list”

– Select board

– Change to “object”

– Select “Action” -> “Execute”

– Select “Restart board to standby ready mode”

EN4416DE20EN© 2004 Siemens AG

Page 15: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

b) using AMO

RESTART-BSSU:ADDRTYPE=PEN,LTU=1,SLOT=91,HFASW=STBYRDY;

4. Switchover the subscribers to the Standby board manually.

a) using the HiPath 4000 Assistant

– Search boards

– Change to “object list”

– Select board

– Change to “object”

– Select “Action” -> “Execute”

– Select “Switchover IP stations to Standby Ready board”

EN4416DE20EN© 2004 Siemens AG

15

Page 16: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

16

SolutionsSiemens

b) using AMO

RESTART-BSSU:ADDRTYPE=PEN,LTU=1,SLOT=61,HFASW=SWITCH,LTU2=1, SLOT2=91;

5. Delete the BPOOL History Data.

a) using the HiPath 4000 Assistant

– Select the “Configuration Management”

– Select “System Data” -> “Maintenance” -> “Board Maintenance”

– Search boards

– Change to “object list”

– Select board

– Change to “object”

EN4416DE20EN© 2004 Siemens AG

Page 17: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

– Select “Action” -> “Execute”

– Select “Reset board pool history”

Repeat this step for board SLOT=61;

EN4416DE20EN© 2004 Siemens AG

17

Page 18: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

18

SolutionsSiemens

b) using AMO

CHANGE-BPOOL:MTYPE=STMIHFA2,TYPE=HISTRES,LTU=1,SLOT=61;

CHANGE-BPOOL:MTYPE=STMIHFA2,TYPE=HISTRES,LTU=1,SLOT=91;;

DISPLAY-BPOOL;

H500: AMO BPOOL STARTED

+------------------------------------------------------------------------------+

| POOLNO = 1 MTYPE = STMIHFA2 HOPAUT = SINGLE |

| INFO = |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 91 HOP-AUT-CNT = 0 HOP-MAN-CNT = 0 |

| DC-STATUS = READY LAN-CONN = READY SMODE = STBYRDY |

+------------------------------------------------------------------------------+

| LTU = 1 SLOT = 61 HOP-AUT-CNT = 0 HOP-MAN-CNT = 0 |

| DC-STATUS = READY LAN-CONN = READY SMODE = NORMAL |

+------------------------------------------------------------------------------+

EN4416DE20EN© 2004 Siemens AG

Page 19: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

4 Extended features for the Keysystem

1. Realize a Secretary-Executive group with a local Keysystem.

– For the needed keys use key modules at the phones.

Solution:

– Adding the Key functions for the Secretary and the Executice:

CHANGE-TAPRO:STNO=7189&4146,DIGTYP=OPTIA1,KY01=LINE,KY02=LINE;

ADD-KCSU:STNO=7146,TYPE=PRIM,PRIMKEY=20,RIOP=YES;

ADD-KCSU:STNO=7189,TYPE=PRIM,PRIMKEY=20,RIOP=YES;

ADD-KCSU:STNO=7146,TYPE=SEC,KYNO=21,STNOSEC=7189,RIOP=NO;

ADD-KCSU:STNO=7189,TYPE=SEC,KYNO=21,STNOSEC=7146,RIOP=NO;

a) The opposing call should be realized by the DSS feature.

Solution:

– Activate the feature „HOTLINE“:

CHANGE-FEASU:TYPE=A,CM=HOTRCL;

– Set authorization “HOT” in the needed COS class:

CHANGE-COSSU:TYPE=COS,COS=33,AVCE=HOT;

– Add two phantom subscribers:

ADD-SBCSU:STNO=7120&7121,OPT=OPTI,CONN=DIR,DVCFIG=OPTISET, COS1=333, COS2=30,LCOSV1=9,LCOSV2=1,LCOSD1=5,LCOSD2=1,STD=101, INS=SIGNOFF,TEXTSEL=ENGLISH;

– Change the key layout for the two subscriber:

CHANGE-TAPRO:STNO=7120&7121,DIGTYP=OPTIT12,KY05=LINE;

EN4416DE20EN© 2004 Siemens AG

19

Page 20: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

20

SolutionsSiemens

– Prepare both subscribers for the Keysystem:

ADD-KCSU:STNO=7120,TYPE=PRIM,PRIMKEY=5,RIOP=NO;ADD-KCSU:STNO=7121,TYPE=PRIM,PRIMKEY=5,RIOP=NO;

– Change the key layout for the Secretary and Executive:

CHANGE-TAPRO:STNO=7189&7146,DIGTYP=OPTIA1,KY03=LINE;

– Extend the existing Keysystem for the Secretary and Executive:

ADD-KCSU:STNO=7146,TYPE=SEC,KYNO=22,STNOSEC=7120,RIOP=YES, DSSLINE=YES;

ADD-KCSU:STNO=7189,TYPE=SEC,KYNO=22,STNOSEC=7121,RIOP=YES, DSSLINE=YES;

– Add Hotline destinations:

ADD-HOTLN:TYPE=HOTDEST,HTLNIDX=1,DEST=7120;ADD-HOTLN:TYPE=HOTDEST,HTLNIDX=2,DEST=7121;

– Add the HOTLINE INDEX to the subscribers:

CHANGE-SDAT:STNO=7121,TYPE=DATA1,HOTIDX=1;CHANGE-SDAT:STNO=7120,TYPE=DATA1,HOTIDX=2;

– Add the “Direct Station Selection for Line” (DSSLINE) to the subscribers:

CHANGE-SDAT:STNO=7120,TYPE=ATTRIBUT,AATTR=DSSLINE;CHANGE-SDAT:STNO=7121,TYPE=ATTRIBUT,AATTR=DSSLINE;

b) The Secretary should has access to the mailbox of the Executive.

Solution:

– Change the key layout for the Secretary:

CHANGE-TAPRO:STNO=7146,DIGTYP=OPTIA1,KY09=MB,KY10=MBLINE;

EN4416DE20EN© 2004 Siemens AG

Page 21: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

– Assign the “Mailbox Line” to the Secretary:

ADD-ZIELN:STNO=7146,TYPE=MBLINE,KYNO=29,STNOMB=7189;

c) The Executive and the Secritary get a Ring Transfer key to switchover the accoustic signaling.

Solution:

– Change the key layout for the Secretary and Executive:

CHANGE-TAPRO:STNO=7189,DIGTYP=OPTIA1,KY06=RULEITNG;CHANGE-TAPRO:STNO=7146,DIGTYP=OPTIA1,KY14=RULEITNG;

– Activate the special authorization for the subscribers:

CHANGE-SDAT:STNO=7189,TYPE=ATTRIBUT,AATTR=RNGXFERL;CHANGE-SDAT:STNO=7146,TYPE=ATTRIBUT,AATTR=RNGXFERL;

– Add the “Ring Transfer” for both subscribers:

ADD-ZIELN:STNO=7189,TYPE=RNGXFERL,KYNO=25,STNORXFR=7146, RXFRFCT=SRC;

ADD-ZIELN:STNO=7146,TYPE=RNGXFERL,KYNO=33,STNORXFR=7189,RXFRFCT=DEST

EN4416DE20EN© 2004 Siemens AG

21

Page 22: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

22

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 23: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

5 Alternative Routing on Error

1. Add an alternative route for any subscriber for the case OOS on error. An incoming call should be routed to a Public Network number (e.g. 0-30300-7xxx).

Solution:

CHANGE-SDAT:STNO=7480,TYPE=DATA1,STNOOOS=0303007341;

2. What happens, if the pen of the station is deactivated by AMO ?

Solution:

The caller gets the Busy Tone.

3. Realize that the incoming calls to this station is also routed to the alternative destination, if the station is deactivated by AMO.

Solution:

CHANGE-SDAT:STNO=7480,TYPE=DATEA1,AMOALTRT=YES;

4. All incoming calls to stations of a special Source Group sould be routet to the attendant in case of error.

Solution:

ADD-APRT:TYPE=ALTERR,SRCGRP=1,ALRTYPE=OOS,ALTRTNR=93,EXTNO=0;

– The following AMO command must be entered, if the alterative route should be used in this case too, if one of the subscribers of the source group is deactivated by AMO:

CHANGE-SDAT:STNO=7xxx&&7yyy,TYPE=DATA1,AMOALTRT=YES;

EN4416DE20EN© 2004 Siemens AG

23

Page 24: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

24

LösungenSiemens

EN4416DE20EN© 2004 Siemens AG

Page 25: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

6 Call Forwarding

1. Realize the "old" call forwarding concept in the HiPath 4000 V2.0 !

Solution:

CHANGE-ZAND:TYPE=ALLDATA3,CFNRDEST=USECFUF;

a) Check the feature depending on AMO COSSU.

Solution:

Add CFNR and CFB in the used COS class and test the function. Both parameters should have the corresponding effect.

b) Are the menus in the Service Menu of the optisets/optiPoints changed?

Solution:

The menus of the Service Menu are not changed by setting the ZAND parameter.To change the Service Menu to the "old" structure, a Patch is needed!

EN4416DE20EN© 2004 Siemens AG

25

Page 26: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

26

ÜbungsaufgabenSiemens

EN4416DE20EN© 2004 Siemens AG

Page 27: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

7 Edit Dial and Callog control

1. Realize the featurel "Edit Dial" in the system.

Solution:

CHANGE-ZANDE:TYPE=OPTISET,EDITDIAL=YES;

2. Testen Sie die Benutzeroberfläche:

Solution:

a) Number corretion before sending it.

Positioning the Cursor with the arrow keys (“<“ and “>”). Delete single digit with the Minus key (“-”).

b) Which keys are necessary for number corrections ?

Arrow keys (“<“ and “>”) and the Minus key (“-”).

c) For which types of terminals can this feature be used ?

Only for UP0E terminals.

d) What about terminals without a display ?

The parameters DIGNODIS and CALLOG in AMO SBCSU have to be set correctly for optiPoint 500 entry and optiset entry and basic (DIGNODIS=YES and CALLOG=NONE).

e) Change for test the parameter “DIGNODIS" to “NO” for an optiPoint 500 entry or opti-set entry / basic.

f) Test the calling situation for the entry/basic.

g) What happens after deactivation/activation of the entry/basic ?

The parameter DIGNODIS is set automatically to the right value. So the correct function is guaranteed.

3. The Callog entries should not can be deleted by the customer in the system.How do you can realize this feature ?

CHANGE-ZAND:TYPE=OPTISET,CALLOG=YES;

EN4416DE20EN© 2004 Siemens AG

27

Page 28: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

28

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 29: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

8 UW7

1. How do you can block the startup of Unix UW7 ?

Solution:

DEACTIVATE-BCSM:UNIT=A1,SYSTEM=UNIX;

EXEC-UPDAT:UNIT=A1,SUSY=ALL;

UNIX startup is blocked for the next restarts/reloads until using the AMO command “ACTIVATE-BCSM:UNIT=A1,SYSTEM=UNIX;“ and “EXEC-UPDAT:......;“.

2. How do you can prevent Logbook entries, caused by UW7 ?

Solution:

CHANGE-FUNCT:LOGBKOFF="2"&"3"&"4";

2= exec-uplo/uplo2

3= regen CPTP

4= reg-funct

EN4416DE20EN© 2004 Siemens AG

29

Page 30: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

30

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 31: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

9 HiPath Backup&Restore (HBR)

1. How is a “Recovery MOD” be created ?

Solution:

Hipath 4000 V2.0 Assistant -> Software Management -> Backup&Restore-> GLA/PDS

Select "HD -> MO"

2. Which RMX Areas of the HD are stored on the “Recovery MOD” ?

Solution:

Area E, F, G, H

EN4416DE20EN© 2004 Siemens AG

31

Page 32: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

32

SolutionsSiemens

3. Which Unix Data are stored on the “Recovery MOD” ?

Solution:

Install Partition of UW7 is stored on Area I of the MOD.

Additionally the Unix DB and RMX DB are store as packed files on the same Area (Area I).

EN4416DE20EN© 2004 Siemens AG

Page 33: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

4. How do you can restore the Unix Data of the “Recovery MOD” ?

Solution:

In the Menu Restore -> Select MO-RMX / Type all /

with Option "Get original list from archive"

-> Select UNIX_CFDATA without RMX

EN4416DE20EN© 2004 Siemens AG

33

Page 34: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

34

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG

Page 35: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

Solutions Siemens

10 CODEW

1. How do you can find “marked resp. blocked” components in the HiPath 4000 V2.0systems ?

Solution:

DISPLAY-SDSU:STATUS=LICMARK,TYPE=PEN,LEVEL=PER3;

DISPLAY-SDSU:STATUS=LICBLOCK,TYPE=PEN,LEVEL=PER3;

2. There are 4 modes in the codeword, which could be activated in a HiPath 4000 V2.0 sys-tem (manually or automatically).

– Which modes are realized ?

Solution:

1. Normal Mode,

2. Trail mode,

3. Emergency mode,

4. Escalated Emergency mode

EN4416DE20EN© 2004 Siemens AG

35

Page 36: Kap 13 EN4416DE20EN - Papagayo System€¦ ·  · 2010-11-18ADD-BCSU:MTYPE=PER,LTG=1,LTU=1,SLOT=61,PARTNO="Q2316-X ",FCTID=3; – Configuring the HFA Standby board data ADD-HFAB:MTYPE=STMIHFA2,LTU=1,SLOT=61,SMODE=STBYRDY;

36

SolutionsSiemens

EN4416DE20EN© 2004 Siemens AG