28
Peter Palensky Principal Scientist Head Complex Energy Systems Austrian Institute of Technology / Energy Department Kann IT Speicher ersetzen?

Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Embed Size (px)

Citation preview

Page 1: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Peter Palensky

Principal Scientist

Head Complex Energy Systems

Austrian Institute of Technology / Energy Department

Kann IT Speicher ersetzen?

Page 2: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

The future energy system

Expectations

Increased share of renewable energy sources

Host new applications like electric vehicles or

cooperative loads

Optimized, resilient, flexible, robust, globalized, etc.

That leads to an increment in:

Distributed structure

Control and management

New energy technologies & markets

Links to other “systems”

IT expected to help!

207.11.2013

Page 3: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

IT and Energy Storage

Adding IT leads to „smart“ something

Benefits if adding IT

Explicitly link processes

• physical, market, social, etc.

Control and optimize processes

More knowledge (state, sensors, analytics, etc.)

IT and Storage

Storage Management

„virtual“ Storage

307.11.2013

Page 4: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

IT for Storage Management

4

Solar Plus House

Zwettl

202,80 m²

Isolating bricks

POROTHERM

48 m² Solar Thermal

9.580 liter storage

Wood stove 40 kW

Activated brick walls

49 m² / 6,5 kWp Photovoltaics11/7/2013

Page 5: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

IT for „virtual“ Storage

Augmented dynamics to mimic storage behavior

Supply Side (primary/secondary control)

Distributed Supply Side

Intelligent inverters

• Feed limit

• Voltage support

Demand Side

Load shedding

Intelligent loads

• Matter transport: pipes, ducts, conveyor belts, etc.

• Thermal inertia

• Schedules/programs: dishwasher, etc.

Coordinated via communication links

507.11.2013

Page 6: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example Project: EcoGrid EU

New energy market design and

implementation

Model-predictive load shed/shift

Interoperability of equipment

Information security

System integration

PowerMatcher, DEMS, grid plausibility,

market platform, CellControler, etc.

OpenADR

Fine grained distribution grid model

parameters

Intelligent demand side

607.11.2013

DEMS: Decentralized Energy Management System (Siemens)

OpenADR: Open Automated Demand Response

Page 7: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

An intelligent demand side

GRID

Voltage support via reactive power in DG

Frequency support via (fair) generation shed, or

Cooperative loads

MARKET:

Reduce consumption peaks / end user costs

Increase renewable generation

Demand elasticity

707.11.2013

DG: Distributed Generation

Page 8: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example: elastic demand

807.11.2013

Page 9: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example: Dynamic Voltage Support

907.11.2013

Load(s)Transformer

Upper limit

Lower limit

Voltage

With PV

Without PV

PV: Photovoltaics

Feeder depth

Page 10: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

EcoGrid EU

1007.11.2013

Regulating power market

Frequency-controlledreserves Inertia

Quantity

Time scale

Days Hours Minutes Seconds Now

Volatility

Direct control

Market-based operation

EcoGrid Real-time

Market

Page 11: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

DSM Time Scales

1107.11.2013

DSM: Demand Side Management

DR: Demand Response

Page 12: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Types of Demand Response

Price Response:

Triggered by wholesale market prices (e.g. Real-time Pricing)

Goal: Peak load reduction

Measure of Success: CO2 / Utility bill savings

Reliability Response:

Triggered by the conditions of the grid

Goal: Peak load reduction upon request from Utilities or DSO/TSO

Measure of success: Financial incentive based on how much electric

load (kW) is reduced

1207.11.2013

DSO/TSO: Distribution/Transmission System Operator

Page 13: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example for DR – Part 1

1307.11.2013

Page 14: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example for DR – Part 2

14

source: Reuters

07.11.2013

Page 15: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Example for DR – Part 3

Texas: 50% of spinning reserves from load

Pumps of petrol industry

Wind dropped from 1700MW to 300MW

Stage 2 emergency: reserves < 1750 MW

1000 MW DR called in Feb 2008

Out of 36 GW -> 2.8%

Restored in

90 minutes

1507.11.2013

Page 16: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Homes: PCT

Programmable

Communicating

Thermostat

California Building Efficiency Standard

16

1902,

Honeywell

2008, Golden Power

07.11.2013

Page 17: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Automated Demand Response: OpenADR

1707.11.2013 ADR: Automated Demand Response

DRAS: Demand Response Automation Server

EMCS: Energy Management Control SystemHVAC: Heating Ventilation, Air Conditioning

Page 18: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

OpenADR Bidding Example

1807.11.2013

Page 19: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

OpenADR in Salzburg: Building2Grid

Needed: Load Models

1911/7/2013

Page 20: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Simple Load Models: Thermal Inertia

Refrigerators as regulation power providers

Frequency-dependent setpoint adjustment

Fairness via communication

2007.11.2013

Page 21: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Slightly more complex load models

2107.11.2013MPC: Model Predictive Control

Page 22: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Modeling - Details

2207.11.2013

Page 23: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

MPC - Results

2307.11.2013

Page 24: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Frequency and demand response

“GridFriendly” (PNNL)

KNIVES (Japan)

California

ORB

Smart AC

PCT

“50.2 Hz problem”

with 10 GW PV inverters

in Germany 2011?

2407.11.2013

PNNL: Pacific Northwest National Laboratory

AC: Air Conditioning

PCT: Programmable Communicating Thermostat

PV: Photovoltaics

Page 25: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Consumer response in Salzburg: Consumer2Grid

Field Trial, 240 Households

2511/7/2013

ConsumerHuman in the Loop

Energy-

Feedback

Database

Energieverbrauchs-Info

Lieber Kunde, Sie haben im

Monat xy 523 kWh verbraucht

Lieber Kunde, Sie haben im

Monat xy 523 kWh verbraucht

Smart Metering

System

Page 26: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Challenges

Interoperability

ISO/IEC 15118 „Road Vehicles –V2G Communication Interface“

IEC 61850 – Substation Automation

CIM – Common Information Model

IEEE 1547 “Standard for Interconnecting Distributed Resources with

Electric Power Systems”

ICT Security

Trusted platforms, updates, personnel, etc.

Complex models

Automatic derivation

Robustness?

2607.11.2013

V2G: Vehicle to Grid

Page 27: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Conclusion

IT can mimic storage behavior

Storage potential depends on domain (building, industry, etc.)

Return of investment

Bits are cheaper than copper?

Bits are cheaper than (real) storages

No explicit storage no chemicals, etc.

Replace? – Not completely

Enable

Support

Part of the solution

2707.11.2013

Page 28: Kann IT Speicher ersetzen? - ak-energie.at · Austrian Institute of Technology / Energy Department ... Load shedding ... (e.g. Real-time Pricing) Goal: Peak load reduction

Thank you

Peter Palensky

Principal Scientist

Head Complex Energy Systems

Austrian Institute of Technology / Energy Department

[email protected]

2807.11.2013