BRUNNER WATER BOILERS
Kamin-Kessel 45/101lifting doors
made in germany
State: 25.02.2013
Kamin-Kessel 45/101 lifting doorsDimension sheet |
with mounting frame 50 mm
VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer
with mounting frame 70 mm
VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer
We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)
Kamin-Kessel 45/101 lifting doorsDimension sheet |
with door frame
VL supply 1"RL return boiler 1"E drain 1/2"SVL supply cooling pipe outletSRL return cooling pipe outletFTAS socket for thermometer cooling TF1 socket 1/2" for thermometerTF2 socket 1/2" for thermometer
We suggest for CAD planing Palette CAD. Permanent updated drawings: www.brunner.deFrames / front versions are marked colored.Art.-Nr I019490 flue gas adapter for horizontal outlet (E= 250mm / A= 200mm)
Planning and installationKamin-Kessel 45/101
meets requirement limit values forGermany / Austria / Switzerland / Norway 1.BlmSchV (Stufe 2) / 15. BVG / LRV / -
Rated heat power
Combustion performanceFlue gas mass flow
adjoining cast iron radiator (GNF10)accumulation rings (MAS)adjoining ceramic accumulatorceramic modular accumulator (KMS system)water boiler
Necessary supply pressure
Firewood consumption
Combustion air consumptionCombustion air connection
Distance to oven chamber wallDistance to floor
WallFloorCeilingBrick lining of protected walls
Data for functional demonstration
Flue gas temperature after
Heat distribution
Cross-section of gratings for max. warm air power
Space inside oven chamber
Heat insulation without / with
Insert / heating surface
Boiler
attached steel smoke hood
Outlet temperature (before heating surface)
Supply airWarm air
kWkg/hkWg/sC
CCCCCCPam/hmm
%
%
cmcm
cmcm
cmcmcmcm
Tested according to
Glass (single / double)
1)
2)
%
max. operating pressuremax. flow temperatureWater volumeConnections flow / return
Water boiler databarClitresinch
EN 13229 W
WeightFireplace + burning chamber 182 + 154 + 89kg
3) air gratings
EN 13229 W
4)
-
24,521,5
----
2001555125
62
20
1010
3100551
-
15 / -
45 - 50
400400
6
40 / 35
19
2315
----
1701245
125
62
201010
-
15 / -
45 - 50
400400
5,2
40 / 35
3100551
Ulrich Brunner GmbHZellhuber Ring 17 -18D-84307 EggenfeldenPhone: +49 / (0)87 21 / 7 71-0Fax: +49 / (0)87 21 / 7 [email protected] | www.brunner.de
BRUNNER products are offered and sold only by qualified dealers and service centres.Subject to technical and assortment changes. Errors excepted.
Approximate value, must be calculated eventually1)2)
Throttle flap recommended
Values with air gratings, stove casing is heat conducting3)heater = body + mounted exchanger4)