O;kolkf;d ijh{k.k fjiksVZ la[;k@ No.: PT-41/403 COMMERCIAL TEST REPORT ekg:@ Month: June, 2013 BATCH TEST KAMCO KMB 200 POWER TILLER Hkkjr ljdkj Government of India d`f"k ea=ky;] (d`f"k ,oa lgdkfjrk foHkkx) Ministry of Agriculture, (Department of Agriculture and Cooperation) nf{k.kh {ks= d`f"k e'khujh izf'k{k.k ,oa ijh{k.k laLFkku Southern Region Farm Machinery Training and Testing Institute VªSDVj uxj] xkyZfnUus - 515 731, ftyk% vuariqj(vka .iz .) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.) Website: www.srfmtti.dacnet.nic.in E-mail: [email protected] Tele./FAX: 08551-286441

KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

  • Upload
    others

  • View
    25

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

O;kolkf;d ijh{k.k fjiksVZ la[;k@ No.: PT-41/403

COMMERCIAL TEST REPORT ekg:@ Month: June, 2013

BATCH TEST

KAMCO KMB 200 POWER TILLER

Hkkjr ljdkj Government of India d`f"k ea=ky;] (d`f"k ,oa lgdkfjrk foHkkx)

Ministry of Agriculture, (Department of Agriculture and Cooperation) nf{k.kh {ks= d`f"k e'khujh izf'k{k.k ,oa ijh{k.k laLFkku Southern Region Farm Machinery Training and Testing Institute VªSDVj uxj] xkyZfnUus - 515 731, ftyk% vuariqj(vka.iz.) Tractor Nagar, Garladinne- 515 731, District: Anantapur (A.P.)

Website: www.srfmtti.dacnet.nic.in E-mail: [email protected] Tele./FAX: 08551-286441

Page 2: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 1

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

Manufacturer

Applicant

: M/s. Kerala Agro Machinery

Corporation Ltd., Athani - 683 585,

Ernakulam District, Kerala.

: The Manufacturer

KAMCO KMB 200 POWER TILLER

Report No. DRAFT Month: MAY Year: 2013

GOVERNMENT OF INDIA

SOUTHERN REGION FARM MACHINERYTRAINING AND TESTING

INSTITUTE, TRACTOR NAGAR, PO: GARLADINNE – 515 731,

DISTRICT: ANANTAPUR (A.P)

Phone No. 08551-286441 Fax No. 08551-286441

Website: www.srfmtti.dacnet.nic.in E-mail: [email protected]

Page 3: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 37

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

16 SUMMARY OF OBSERVATIONS, COMMENTS &

RECOMMENDATIONS

Evaluative (mandatory)/ Non-evaluative (non-mandatory) parameters

applicable for Qualifying Minimum Performance Criteria as per Clause – 4.1

(Table-1) of IS: 13539: 2008 for acceptance of the power tiller for the purpose

of subsidies / NABARD financing are summarized as under:

Sl.

No.

Characteristics

Category

(Evaluative/

Non

Evaluative)

Requirements as

per IS: 13539:

2008

Values

declared

by the

applicant/

Requirem

ents

As

observed

Whether

meets the

requireme

nts

(Yes/No)

1 2 3 4 5 6 7

16.1 Engine Performance:

a)

Max. power

under two

hours test,

(kW)

Evaluative

Declared value to

be achieved with a

tolerance of -

7.5/+15 percent of

the declared value

7.0

6.7

Yes

b) Power at rated

engine speed,

(kW)

Non – evaluative

±5 %

6.7

6.7

Yes

c) Specific fuel

consumption

corresponding

to max.

power, ( g/kWh )

Non –

evaluative

5%

270

295

No

d) Specific fuel

consumption

corresponding

to rated

power, ( g/kWh )

Non – evaluative

5%

265

295

No

e) Max.

equivalent

crankshaft

torque (Nm)

Non – evaluative

8%

32.6

32.6

Yes

Page 4: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 38

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

f) Max. operating temperature (deg. C) :

- Engine oil

Evaluative

The declared

value should not

exceed the max.

value specified by

the oil company

and observed

value under high

ambient condition

should not exceed

the declaration

90

89

Yes

-Coolant,

(water)

Evaluative

The declared

value should not

exceed the boiling

temperature of

coolant under

pressurized

condition or

otherwise and the

observed value

under high

ambient condition

should not exceed

the declaration.

104

103

Yes

g) Lubricating

Oil

consumption,

(g/kWh)

Evaluative

Not exceeding 1%

of SFC at max.

power under high

ambient condition

2.0

2.1

Yes

h) Maximum

coolant,

(water)

consumption,

(% of total

coolant

capacity)

Non – evaluative

The observed

value should not

exceed the

maximum value

specified by the

manufacturer

when evaluated

under high

ambient

conditions.

18.1

9.86

Yes

Page 5: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 39

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

i)

Smoke level

Evaluative

Max light

absorption

coefficient of

3.25/m or

equivalent Bosch

No. 5.2 or 75 Hetridge value

(As per CMVR)

Maximum

light

absorption

coefficient

of 3.25/m

Light absorptio

n coefficie

nt of 1.59 per

meter

Yes

j)

Overheating

tendency of

the engine

Evaluative

Satisfactory

completion of 2

hours test under

high ambient

condition.

--

Satisfac- tory

Yes

16.2 Rotary shaft performance:

a)

Max. Power

test, (kW)

Evaluative

Minimum 75 percent of obse

rved maximum

bhp for power

tiller above 5 hp

and 65 percent for

the power tiller

below 5 hp.

5.0

5.7

Yes

b) Power at rated

engine

speed,(kW)

Non – evaluative

- 10%

5.0

5.7

Yes

c) Specific fuel

consumption

corresponding

to power at

rated engine

speed,(g/kWh)

Non – evaluative

+ 10%

330

316

Yes

d) Max.

equivalent

rotary shaft

torque, Nm

Non – evaluative

8%

250

260

Yes

e) Max.

operating

temp. of

rotary

transmission

oil, (oC)

Non – evaluative

The observed

value should not

exceed the

maximum value

specified by the

manufacturer.

70

67

Yes

Page 6: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 40

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

f) Rotary shaft

power rating,

(kW)

Non – evaluative

To be declared by

the manufacturer

5.0

5.7

Yes

16.3 Drawbar Performance :

i) Maximum

drawbar pull

corresponding

to 15% wheel

slip, (kN).

Evaluative

Minimum 60 % of

static mass with

ballast

2.8

4.1

Yes

ii) Maximum

drawbar

power, (kW.)

Non – evaluative

- 10%

4.4

4.9

Yes

iii)

Maximum transmission oil temperature,

(oC)

Non – evaluative

The declared

value should not

exceed the

maximum value

specified by the

oil company and

the observed value

should not exceed

the declaration.

85

73

Yes

16.4 Brake Performance:

a)

Service brakes

Evaluative

Should meet the

requirement under

CMVR

--

--

--

b) Parking

brakes:

Observation

on rotation of

cranked

wheels at the

slope of 12%

facing up and

facing down

Evaluative

No rotation of

drive wheels at a

slope of 12

percent facing up

and facing down

No

rotation of

drive

wheels

No

rotation

of drive

wheels

Yes

16.5 Air cleaner oil pull over:

Maximum

percentage of

oil pull over

(mass basis)

Evaluative

0.25

0.25

0.17

Yes

Page 7: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 41

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

16.6 Noise level:

a) Maximum

ambient noise

emitted by the

power tiller,

dB(A)

Evaluative

As per CMVR

(88 dB(A))

82

Yes

b) Maximum

noise at

operator’s ear

level,

dB (A)

Evaluative

As per CMVR

(98 dB(A))

94

Yes

16.7 Amplitude of mechanical vibration at (microns):

a) Steering

handle grips

Non-

evaluative

100 m, max.

384

No

b)

Gear levers Non-

evaluative

100 m, max.

307

No

c) Clutch / brake

lever(s)

Non-

evaluative

100 m, max.

357

No

d) Rotary shaft

speed change

lever

Non-

evaluative

100 m, max.

329

No

e) Steering

clutch lever

Non-

evaluative

100 m, max.

341

No

f) Accelerator

lever

Non-

evaluative

100 m, max.

233

No

16.8 Haulage Performance:

a) Gross load of

trailer (t)

Non-

evaluative

--

1.0

1.0

Yes

b) Distance

traveled / liter

of fuel

consumption,

(km)

Non-

evaluative

--

11.67 to

12.5

12.19 to

12.49

Yes

c) Fuel consu-

mption,(cc/

km/tonne)

Non-

evaluative

--

80 to 85.7

80.06

to 82.03

Yes

Page 8: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 42

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

16.9 Stationery operations:

Stationary

operations

Evaluative

Should have the

provision for

power outlet for

stationery

operations or

recommended

agricultural appliances

--

Provided

Yes

16.10 Discard limit (mm):

a)

Cylinder bore

diameter

Evaluative

To be specified by

the manufacturer

in printed

literature

95.20

95.02

Yes

b)

Piston

clearance

Evaluative

To be specified by

the manufacturer

in printed

literature

0.152

0.14

Yes

c) Ring end gap:

iii. 1st

Com

p.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

1.5

0.24

Yes

- 2nd

Comp.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

1.5

0.25

Yes

- 3rd

Comp.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

1.5

0.25

Yes

- 1st

Oil ring

Evaluative

To be specified by

the manufacturer

in printed

literature

1.5

0.27

Yes

- 2nd

Oil ring

Evaluative

To be specified by

the manufacturer

in printed

literature

1.5

0.27

Yes

Page 9: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 43

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

d) Clearance of big end bearing:

-Diametrical

Evaluative

To be specified by

the manufacturer

in printed

literature

0.25

0.07

Yes

- Axial

Evaluative

To be specified by

the manufacturer

in printed literature

0.25

0.19

Yes

e)

f)

Ring groove clearance:

- 1st

Comp.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

0.20

Tapered

Yes

- 2nd

Comp.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

0.20

0.04

Yes

- 3rd

Comp.

Ring

Evaluative

To be specified by

the manufacturer

in printed

literature

0.20

0.04

Yes

- 1st

Oil ring

Evaluative

To be specified by

the manufacturer

in printed

literature

0.20

0 .0 3

0.03

Yes

- 2nd

Oil ring

Evaluative

To be specified by

the manufacturer

in printed

literature

0.20

0.04

Yes

Thickness of

clutch lining

Evaluative

To be specified by

the manufacturer

in printed

literature

5 ± 0.1

5.05 to

5.07 mm

Yes

g) Clearance of main bearing:

Diametrical

clearance

Evaluative

To be specified by

the manufacturer

in printed

literature

Ball

Bearing

NA

---

Page 10: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 44

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

Crankshaft

end float

Evaluative

To be specified by

the manufacturer

in printed

literature

0.27

0.18

Yes

16.11 Safety requirements:

a) Provision of

guards on

moving parts

other than

otavator.

Evaluative

Yes

Yes

Provided

Yes

b) Location and

direction of

exhaust

emission to be

away from the

operator and

machine for

stationary operation.

Evaluative

Yes

Yes

Provided

Yes

c) Covers on hot

parts

Evaluative

Yes

Yes

Provided

Yes

d) Locking of

parking stand

lever

Evaluative

Yes

Yes

Provided

Yes

e) Protective

shield for

otavator to

prevent flying

of mud and

stones

Evaluative

Yes

Yes

Provided

Yes

f) Accidental

engaging of

reverse speed

gear when

rotary is in

operation.

Evaluative

Yes

Yes

Provided

Yes

g) Provision of

head lights

Evaluative

Yes

Yes

Provided

Yes

Page 11: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 45

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

16.12 CATEGORY OF BREAKDOWNS/DEFECTS:

S. No.

Characteristi

cs

Category

(Evaluative/

Non-

evaluative)

Requirements as

per IS: 13539-

2008

As

observed

Whether meets the

requirements

(Yes/No)

1.

Critical

Evaluative No critical

breakdown

None

Yes

2.

Major

Evaluative

Not more than two

and neither of

them should be of

repetitive in nature

None

Yes

3.

Minor

Evaluative

Not more than five

and frequency of

each should not

more than two.

None

Yes

16.13 Salient Observations:

16.13.1 Engine Performance:

i) The backup torque is 2.19% only, which is very low and needs to be

improved.

ii) The maximum brake horse power of the engine at 2000 rpm was

observed as 6.7 kW during maximum power two hours test.

iii) The specific fuel consumption corresponding to max power was

recorded as 295 g/kWh against declared value of 270 g/kWh. This

should be looked into. iv) The pressure release setting and minimum permissible pressure of

lube oil pump is specified as 215 kPa and 2.5 kPa respectively. This

should be looked into.

16.13.2

Rotary shaft performance:

i) The maximum rotary shaft power was measured as 5.7 kW.

ii) The rotary power at rated engine speed was measured as 5.7 kW.

16.13.3

Drawbar performance test:

i) The power tiller developed 4.9 kW Power during drawbar

performance test in H1 gear corresponding to 15% wheel slip.

Page 12: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &

PT-41/403 KAMCO KMB 200 POWER TILLER

COMMERCIAL (BATCH TEST) 46

SOUTHERN REGION FARM MACHINERY TRAINING & TESTING INSTITUTE - ANANTAPUR

16.13.4 Mechanical Vibration:

The amplitude of mechanical vibration on maximum controls /

measuring points of the power tiller exceeded the limit of 100 micron.

It should be dampened down to improve operational comfort and life

of the components.

16.13.5

Noise measurement:

Max. Noise at operator’s ear level and by stander’s position was

observed as 94 dB (A) and 82 dB (A). The noise observed at

operator’s ear level is more than the limit specified by IS: 12239

(Part 3) – 1988. This should be looked into.

16.13.6

Haulage test

16.13.6.1 The power tiller was recommended for haulage test with a trailer of

gross mass of 1.0 tonne

16.13.6.2 Distance traveled per litre was observed 12.19 to 12.49 km.

16.13.6.3 Specific fuel consumption was observed 80.06 to 82.03 cc/km/ton

16.13.7 The chemical composition of the blades does not conform, in full, to IS: 6690-1981.

16.13.8 The Hardness of the blades does not conform, in full, to IS: 6690-

1981.

16.13.9 As per IS: 12239 (Part 3) – 1988, “maximum safe speed” with trailer

is required to be specified by the manufacturer. Necessary action may

be taken in this regard.

16.13.10 As per IS: 12239 (Part 3) – 1988, balancing mass to be added to

achieve correct weight balance of the power tiller with various

attachments should be recommended by the manufacturer in the operator manual. This may be examined for compliance.

16.13.11 Provision of spark arresting device may be considered for

incorporation in the exhaust system.

16.14

General observation:

The handle grip does not meet the requirement of IS: 11858 – 1986.

This may be looked into for compliance.

16.15

Maintenance / Service problems:

No noticeable maintenance / service problem was observed during the

test. Provision for draining of sediments/water in fuel tank may be

provided to check contamination/impurities in fuel.

Page 13: KAMCO KMB 200 POWER TILLERsrfmtti.dacnet.nic.in/Test reports upload 2013-2014/403.pdfKAMCO KMB 200 POWER TILLER COMMERCIAL (BATCH TEST) 38 SOUTHERN REGION FARM MACHINERY TRAINING &