30
K800 FIT Fuel Island Terminal (Hybrid)

K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid C/OPT FIT500

Embed Size (px)

Citation preview

Page 1: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

K800 FITFuel Island Terminal (Hybrid)

Page 2: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

TerminalsFeatures – Identity Formats

K800 Hybrid

C/OPT FIT500

Page 3: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

TerminalsFeatures – Heater

K800 Hybrid

C/OPT FIT500

Provides reliable operation in the coldest climates

Page 4: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

TerminalsFeatures – Receipt Printer

K800 Hybrid

C/OPT FIT500

ThermalOn Demand Receipts

Customizable Header, Trailer, & Body (proprietary only)

02/10/99 12:37 PMCARD #1: 0300000000000001CARD #2: 0300000000000002TRANS #: 46PRODUCT: UNLEADED QUANTITY: 40.000PR/UNIT:$ 1.290TOTAL: $ 51.60DRIVER: MR EDACCT.NAME: ACME TRUCKINGSITE I.D.: 1MISC: 54785ODOM: 22345M.P.G. 4.7PUMP #: 1 - 1ACCOUNT#: 1000

Page 5: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Requires K800 FIT software 21.01H or up

All FSC3000s Sys2 requires FSC software 21.01D/33.07 or up

Petro-Net is fixed at 9600

PCT is integrated with the FIT(FIT 1 is PCT 1, FIT 4 is PCT 4, Etc.)

No Receipt Printer

K800 FIT/PCT w/ FSC3000 (Hybrid)

Page 6: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Fuel Island Terminal (FIT) Features

Built-In DiagnosticsSimplified trouble-shooting

Up to 4 Terminals Supported

Each FIT controls up to 4 fueling points simultaneously (Max. 16 fueling points)

Page 7: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

K800 Fuel Island Terminal (FIT) Overview

Display

ReaderPV247 FIT

Board

Keypad Main Cable

Page 8: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FIT Power & Communication Wiring

CircuitPanel

Indoors

Outdoors

Petro-Net Junction Box

FIT Power and Petro-Net Wires

PeripheralPower Outlets

OR

Petro-Net can be wired as Star or daisy chain

Page 9: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FIT Pump & Pulser Conduit & WiringPumps Pumps

Wiring Trough

Indoors

Outdoors

Pump Junction Box

Pump Power and Pulser Wires

Existing Conduit

New Conduit

CircuitPanel

Page 10: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000 ControllerFeatures and Benefits

Compatible with System2 componentsSystem2 FITs, PCTs

Configurable with Windows-based software

Command-Line Programming

Store up to 2000 transactions

Page 11: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000 Controller Capabilities

Downloadable Firmware & Option Upgrades

Optional Built-in Dial-in Modem

Standard Built-in Ethernet

Office journal printer for transaction backup

Support Wireless Communications to Terminals

Page 12: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000 Controller Local Proprietary Record Features

Single or Dual-Entry (Driver & Vehicle)

Account Grouping

Restrictions – Product, Quantity, Allocations, Reasonability

Personal Identification Number (PIN)

Supports over 60,000 Records (9999 accounts)

Odometer Tracking

Additional Programmable PromptsAlphanumeric, verified

Page 13: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000 ControllerNetwork Capability

Dial-out to up to 8 different networks ComdataT-Chek

FleetOneTCHEFS

PaymentechCredit Cards

Wright ExpressVoyagerFuelman

CFNNBS

Dual-Host Authorization

Registered Bank Card

Page 14: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000 Controller Reporting Features

Pump an Product total reports

Declining Inventory Report

Midnight Totals

PUMP #1 TOTALS: 512.5 TOTALIZER: 512.5PUMP #2 TOTALS: 1154.0 TOTALIZER: 1154.0PUMP #3 TOTALS: 1158.7

TOTALIZER: 1158.7

PREMIUM QTY: 11748.0 GALLONUNLEADED QTY: 10900.0 GALLON REGULAR QTY: 10000.0 GALLON MRKD FUEL QTY: 11748.0 GALLON #1 DIESEL QTY: 10900.0 GALLON#2 DIESEL QTY: 10000.0 GALLON GASOHOL QTY: 11748.0 GALLONALCOHOL QTY: 10900.0 GALLON

TANK #1 PREMIUM QUANTITY: 11748.0 LOW LEVEL: 2000.0TANK #2 UNLEADED QUANTITY: 10900.0 LOW LEVEL: 2000.0TANK #3 REGULAR QUANTITY: 10000.0 LOW LEVEL: 2000.0TANK #4 MRKD FUEL QUANTITY: 11748.0 LOW LEVEL: 2000.0TANK #5 #1 DIESEL QUANTITY: 10900.0 LOW LEVEL: 2000.0TANK #6 #2 DIESEL QUANTITY: 10000.0 LOW LEVEL: 2000.0TANK #7 GASOHOL QUANTITY: 11748.0 LOW LEVEL: 2000.0TANK #8 ALCOHOL QUANTITY: 10900.0 LOW LEVEL: 2000.0

Page 15: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

ARTWare Windows-base configuration tool

Simplifies Configuration

Off-line or On-line

Global database for common site parameters

Separate databases for different customers

Page 16: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

TerminalsFeatures

With the ART system the customer can choose one of our 3 terminals to meet the his needs.

K800 Hybrid FITFuel Island Terminal

C/OPT Commercial Outdoor Payment Terminal

FIT500

Fuel Island Terminal

Page 17: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

TerminalsFeatures

Support for up to 8 terminals.

Pump Restriction to specific terminals

Page 18: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Pump ControlFeatures

The FSC3000 is capable of controlling up to 32 fueling points. The system can control both mechanical and electronic

pumps or a combination of them.

Note: With electronic pumps there may a hardware limitation that

may decrease the number of fueling points that can be controlled.

Page 19: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Pump ControlFeatures

Time-OutsHandle, First Pulse, Missing Pulse (MPD), Total Fueling

Configurable Pulse per unit

Pump Sentry

Product Restrictions Hose restrictions on multi-product dispensers

when using DPC or UPC option is used

Page 20: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Pump ControlMethods

Mechanical Pump Control by Pump Control Module (PCM)or K800 Hybrid Integrated Pump Control

Note: Pump Control Terminal (PCT) no longer sold with new systems still exist in large numbers

Electronic Pump Control by Universal Pump Control (UPC)using manufacture’s console or pump controller

Electronic Pump Control by Direct Pump Control (DPC)Controlling pumps directly

Page 21: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

ART SystemFunctional Overview

1) Driver inserts his card

2) System prompts for additional information (PIN #, Mileage, etc.)

3) Driver selects his pump #

4) Driver begins fueling his vehicle

5) When finished driver reinserts his card and gets receipt.

Page 22: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

Specifications / Components

LEDs, Switch & Jumper Settings

Power & Peripheral Connections

Installation

Cold Start Procedure

FSC3000Fuel Site Controller

Page 23: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000Front/Back View Information Display

Function Buttons

Page 24: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

FSC3000Inside View

Warning: This contains high voltage inside the unit and should

be unplugged when servicing

Battery

SIMM Card

Page 25: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

DPCWith the ART system you are now able to control

electronic pumps without having the additional hardware required with a UPC.

Direct Pump Control

Page 26: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

32 Fueling Points (may be hardware limitations)

Directly interfaces to pump distribution boxes

Supports the following Brands Gilbarco, Tokheim, Wayne

DPC - Electronic Pump Control

Page 27: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

DPCGilbarco

CRIND LOOPPUMP LOOP

75-2036*

Gilbarco D-Box

RS422 Convertor

PowerSupply

PUMP LOOP

JP10 &

JP11

RS-422 CableGilbarco Part #

R19249G1

Jumper JP1 OFF

All switches OFF

Gilbarco Direct Pump Control DPC) Wiring

12-1018*RJ45 Cable

Port #4

FSC3000

20-1519-04*

* = Included with 20-4260 option

PrewiredCables

Page 28: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

DPCTokheim

Page 29: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500

DPCWayne

Wayne Data Distribution Box

20-7068 Current Loop Convertor

Wayne Direct Pump Control (DPC) Wiring

12-1018*RJ45 Cable

* = Included with 20-7068

Front view

Port #4

FSC3000

1 2 3 4 5 6 7 8

+ - + -Data in Data out

+ - + -Data outData in

GN

D (R

ed

)

12VA

C (W

ht/Blk)

}

To 2nd Data Distribution Boxfor Pumps 17-24}

Rear view

12VAC

Transformer*

Wayne part number 80017-001-016

Page 30: K800 FIT Fuel Island Terminal (Hybrid). Terminals Features – Identity Formats K800 Hybrid  C/OPT  FIT500