k-tech-book 2

Embed Size (px)

Citation preview

  • 8/12/2019 k-tech-book 2

    1/14

    Centrifugal

    Slurry

    Pump

    Wilfley

    M o d e l KTechnical Handbook

  • 8/12/2019 k-tech-book 2

    2/14

    Wilfley Model K Pumps

    A Slurry Pump for the Most Abrasive Slurries

    Single stage Side suction Horizontal To 12" discharge

    Sealess Design

    The Wi lf ley Expeller No water gland, pump or piping

    No mechanical seals No air pressure No stuffing box

    A Wilfley Can Run Dry becausethere is no Rubbing Contact whileRunning

    No dilution No contamination No leaking while running

    Wilfleys are sealed by hydraulicpressure while running. Thiscentrifugal seal is created by theexpeller which was developed morethan 80 years ago. Wear isminimized on the Wilfley expellerbecause it operates against suctionpressure only.

    Leakless at Shutdown

    The Wi lf ley Check Valve Long wear life Low cost Reliable Easily cleaned

    When the K is shut down, thecheck valve seals against the shortcylinder head.

    Maintenance

    The Wi lf ley Design Advantage Quick change wear parts Dual Side intake

    Maintenance is a majorconsideration in the development of

    all Wilfley Pumps. All moving partsin the K can be changed withoutdisturbing the suction or dischargepiping.

    Service-Support

    Wilfley Integrity Large replacement inventory Engineering assistance for the lifeof the pump Quality craftsmanship

    A.R. Wi lf ley & Sons has alwaysproduced the finest sealesscentrifugal pumps. W ilfley iscommitted to quality, durability andcustomer satisfaction. Wilfley stillsells parts for and services pumpsthat have been in continuousservice for more than 80 years. It isa tradition at Wilfley. The Wilfley K continues the legacy that is A.R.Wilfley & Sons.

    Discharge

    Expeller createspressure keepingfluid from shaft.

    Impeller pumpsfluid from intaketo discharge

    Suction Inlet

    1

  • 8/12/2019 k-tech-book 2

    3/142

    General Installation Recommendations

    This list will help establish specificpumping conditions.

    Solution Temperature Static Head Discharge Pipe Size Length, Discharge Pipe Discharge Pipe Fittings Equivalent Length Discharge Pipe Total Head

    Maximum Suction Pressure Minimum Suction Pressure CapacityGPM Specific Gravity % Solids by Weight Maximum Size of Solid Particles Mesh Analysis Electrical Characteristics Viscosity

    Choosing Pump Location

    The following recommendationsmay be helpful when choosing thebest location for your pump.

    a. Locate the pump as close to theliquid source as practical so thatthe suction pipe is short and directwith a minimum of elbows, fittingsand valves

    b. Place the pump in a location sothat the unit is accessible forinspection during operation as wellas for maintenance operationsinvolving removal and disassembly.

    Foundation

    The founda tion should besufficiently substantial to absorbany vibration and to form apermanent, rigid support. A concrete foundation on a solid baseis satisfactory. Foundation bolts of the proper size should beembedded in the concrete locatedby the outline drawing.

    Alignment The pump and motor are al igned atthe factory before shipment.Realignment may be necessary afterthe complete unit has been leveledon the foundation and after thefoundation bolts have beentightened. Explicit directions forchecking and aligning the pumpcomponents may be found in theHydraulic Institute Standards.

    Wilfley hydraulic seal in actual operation.

  • 8/12/2019 k-tech-book 2

    4/14

    Features and Components

    This closed type impeller withextra thick shrouds and vanesis available in standard portdesign or wide port design forviscous, frothy, or large particleslurries. The unique designhelps to maintain excellentperformance characteristicsthroughout its wear life.

    Crane assembly (not illustrated)allows the case to be opened orremoved quickly without usingseparate lifting equipment.(available in sizes 3" through 8")

    The extra heavy wall thickness andspecial volute design extends wear life.

    The impeller bolt functions both asa shear pin and to hold the impelleragainst the taper of the shaft.

    The integrated bell-shaped expellerprovides a positive hydraulic leakagesealing arrangement eliminatingmaintenance associated with packing,water glands, or mechanical seals.

    The heavy section follower platecan be rotated to prolong wear life.

    The frame protecting ring is made ofabrasion resistant material to protect

    the inlet chamber from excessive wear.

    The rear inlet design allows for removalof the case without disturbing piping,reduces surging, controls pre-whirl, andcan be vented for froth applications.

    The case bolts are extra largeso that fewer are required.Each nut is convenientlylocated for quick disassembly.

    3

    The discharge keeperassembly supports thedischarge piping duringmaintenance so that the

    case can be opened orremoved withoutdisconnecting piping.

    The centrifugallyoperated check valveprovides a seal atshut-down and opensthe seal at start-up toinsure that there is norubbing contact whilethe pump is running.

  • 8/12/2019 k-tech-book 2

    5/14

    The draw bolt is provided to adjust forwear to maintain peak pump performance.

    The shaft is made of extrastrength, high quality steel.Bearing shoulder diameters areground for precision bearing fits.

    Convenient, sturdy oil fillerelbow allows for simplepositive check on oil level.

    The long cylinder has a largeoil reservoir for superior bearinglubrication. Bearing bores aremachined to precise concentricityfor proper bearing alignment.

    The frame base is made of castiron with heavy rib reinforcementto withstand stresses.

    Rubber Lined Intake Chamber optional

  • 8/12/2019 k-tech-book 2

    6/144

    1. Impeller Seal Face Adjustment -to maintain efficiency

    One of the losses in a centrifugalpump is the re-circulation of thepumpage in the pump case backinto the suction of the impeller. Theamount of re-circulation dependsupon the clearance between theimpeller and the follower plate.On the Wilfley Model K pump aMINIMUM clearance is maintainedby a simple adjustment. This Wilfleyfeature is appreciated by all operatorsbecause it eliminates the need forincreasing the pump speed, addingmakeup water, early replacement of pump parts and other methods of maintaining efficiency.

    2. Quick Change out of Wear Parts -to minimize down time

    The five key wear parts case,impeller, follower plate, frameprotecting ring and die ring canbe changed within a few minuteswithout disturbing the suction or

    discharge piping. This quick changeis made possible by the case crane(available on sizes 3"-8"), dischargekeeper, the use of only four casebolts, and the manner in which theimpeller is attached to the shaft.

    This exclusive Wilfley feature savesvaluable time and manpower overother solids handling pumps that mayrequire hours to make accomplishsuch required maintenance.

    Maintenance Features

  • 8/12/2019 k-tech-book 2

    7/14

    K Pump Capacities

    2x1 2 1 / 2 x11 / 2

    175

    150

    125

    100

    75

    50

    25

    H - F

    T .

    10 100 1,000 10,000

    CapacityGPM

    4x24x2 1 / 2

    5x3 6x4 8x5 10x6

    12x8

    14x10

    16x12

    Model K 2" x 1" through 12" x 8"Model L 14" x 10" through 16" x 12"

    5

  • 8/12/2019 k-tech-book 2

    8/14

    General Characteristics

    Model K pumps are available indischarge sizes ranging from 1"to 12". Cram arm assemblies thatsupport the case during maintenanceare available in discharge sizes 3"to 8". Larger pumps, designatemodel L use support base to slidethe case away from the pump.Special pump configurations areavailable for high suction head andextreme horsepower services. Eachpump is engineered to match serviceand system requirements.

    Special Modifications

    We are equipped to modify pumpsthat are used for special services.Such things as flush ports, speciallubrication systems and specialdrain plugs are common. We willalso engineer modifications requiredto fit your specific installation.

    We provide engineering modificationsfor related pumping problems such

    as maintenance and installation. Manyapplications require specific motor

    and drive configurations as well asbase plates and mounting brackets.We will design and produce theseitems to your specifications andsatisfaction. We also have the capabilityto supply pumps with a number of exotic corrosion resistant paints.

    Materials of Construction

    A.R. Wilfley & Sons produces model K pumps in a variety of hard irons andstainless steels including proprietaryallows specially developed to standup to the difficult erosive-corrosiveconditions found in slurry services.

    Wilfley Model K pumps are alsoavailable in natural rubber, syntheticelastimers and urethane.

    Wear in a slurry pump is a complexprocess. It is a function of: The size and concentration of the

    solid particles The shape and hardness of the

    solid particles Temperature PH level

    This type of wear invo lves sl idingand impact erosion in conjunctionwith corrosion. This combinationintensifies the effects of eachindividual type of wear. Materialhardness, fracture toughness andcorrosion resistance must beproperly balanced to providereasonable wear resistance. A.R.Wilfley & Sons developed proprietaryalloys that optimize this balance forpumping conditions where standardallows were not adequate. Maxalloy5 and Maxalloy 8 are two proprietaryalloys that significantly surpasstraditional white iron and NiHard incorrosion, erosion and corrosion-erosion services.

    A. R. Wil fl ey & So ns has ov er80 years of experience designing,manufacturing and applying slurrypumps and can provide theexpertise to assist in selection of pumps and materials for a widevariety of difficult services.

    Material

    White ironNiHard 4

    Maxalloy 5

    Maxalloy 8

    HardnessHBN

    400-600620-670

    580-720

    415-520

    TensileStrength(psi)

    45,00080,000

    80,000

    90,000

    FractureToughness(psi)

    12,00022,000

    30,000

    20,000

    ApplicationRange(pH)

    5 84.5 8.5

    3.6 9.5

    1.3 12.2

    6

  • 8/12/2019 k-tech-book 2

    9/14

    Pump Weights and Sump Dimensions

    Complete Metal Pumps

    Pump Size

    Bare Pump

    Direct Driven Pump with baseplate and flexible coupling

    Overhead V-Belt Driven Pump withFixture (Less Sheeves & Belts)

    Approximate Shipping Weight in Pounds

    1

    430

    640

    700

    1 1 / 2

    450

    665

    720

    2

    680

    1060

    950

    21 / 2

    690

    1060

    960

    3

    1030

    1350

    1300

    4

    1675

    2120

    2185

    5

    2150

    2600

    2820

    6

    2550

    3350

    3140

    8

    4150

    5450

    4850

    10

    6320

    8230

    7420

    12

    7900

    10290

    9275

    14

    9875

    12860

    11600

    Sump DimensionsPump Size

    WInches

    HInches

    I Inches

    1" & 1 1 / 2"

    18

    36

    46

    2" & 2 1 / 2"

    24

    36

    57

    3"

    30

    42

    68

    4"

    36

    48

    79

    5"

    4842 Min.

    54

    9690 Min.

    6"

    6048 Min.

    66

    118106 Min.

    8"

    7260 Min.

    72

    135123 Min

    10"

    8475 Min.

    8475 Min.

    166150 Min.

    12"

    132120 Min.

    8475 Min.

    166150 Min.

    14"

    150

    96

    192

    16"

    190

    108

    210

    Intake Sump

    It is desirable to feed the Wilfleypump by means of sump tank orfeed box placed as close to thepump as possible. Recommendedsump sizes are given below. Whenthe feed to the pump is increasedor decreased, the material in thesump simply seeks a higher orlower level, respectively. Hopperbottom sumps are much moresatisfactory than flat bottom sumps.

    A sloping pipe from the intake sumpinto the pump is particularly desirablewhen handling materials that settlequickly, such as concentrates andcoarse sands, or when the quantityis small for the size of intake pipeand pump. Long suction pipesrequire sufficient velocity in the pipeto prevent setting.

    Suction Piping

    Suction pipe may be connected toeither or both sides of the pump andneed not be disturbed to change thepumping parts or bearing unit.

    It is preferred that thesump tank is designatedfor a minimum of 3minutes restriction time.

    7

    I

    CL of Intake

    45 o

    45 o

    45 o

    H

    WW

    Alternative SumpConstruction

  • 8/12/2019 k-tech-book 2

    10/14

    Dimensions in Inches

    Size

    111 / 2221 / 234

    568

    Discharge

    111 / 2221 / 234

    568

    Suction

    221 / 24456

    81012

    A

    5959651 / 2651 / 267801 / 2

    91931 / 2114

    B

    11 1 / 411 1 / 4131 / 8131 / 8145 / 8157 / 8

    171 / 2181 / 224

    C

    3737423 / 4423 / 4423 / 4461 / 4

    6361763 / 4

    D

    101011 3 / 411 3 / 4131 / 4141 / 2

    1617223 / 8

    E

    11111212121 / 416

    14161 / 4243 / 4

    F

    1111103 / 4103 / 412181 / 4

    14161 / 4121 / 2

    G

    93 / 893 / 811 1 / 211 1 / 2131 / 8141 / 8

    153 / 8165 / 8215 / 8

    *H

    2424281 / 2285 / 83140

    433 / 8553 / 4627 / 8

    J

    13131515161 / 4203 / 8

    22233 / 4281 / 4

    K

    1111131 / 2135 / 8143 / 4195 / 8

    213 / 831**345 / 8

    L

    11 / 211 / 213 / 413 / 431 / 25

    851 / 291 / 2

    M

    51 / 451 / 261 / 261 / 277 / 893 / 4

    11 3 / 8121 / 4133 / 4

    N

    101 / 4101 / 411 3 / 411 3 / 4131 / 215

    151 / 2187 / 820

    O

    2233 / 833 / 853 / 861 / 4

    33 / 453 / 491 / 4

    P

    75 / 875 / 891 / 891 / 8137 / 8121 / 2

    20171 / 422

    Q

    11 / 211 / 217 / 817 / 817 / 817 / 8

    11 / 217 / 821 / 4

    R3 / 43 / 43 / 43 / 43 / 43 / 4

    7 / 87 / 87 / 8

    S

    223 / 8223 / 8253 / 4253 / 42315 / 16273 / 4

    34377 / 8375 / 8

    T

    11 / 811 / 811 / 211 / 211 / 211 / 2

    13 / 413 / 413 / 4

    U

    411 / 16413 / 1657 / 16511 / 1677 / 891 / 2

    103 / 411 3 / 4161 / 4

    V

    413 / 16413 / 1661 / 1661 / 16513 / 168

    33 / 445 / 810 1 / 4

    Dimension P is the minimum clearance for removing wearing parts. Provide ample clearance at this point for removing the wearingparts as they are very heavy.Dimension K is distance from center of pump to outside of discharge sleeve.Dimension N is distance from center of pump to outside of suction flange. the feed may be from either side.Use 1 1/2" pipe sleeves around foundation bolts and allow 1/2" for grouting. Place valves in suction and discharge lines near pump.The suction line should be short, free from elbows if possible, and sloping when heavy materials or large particles are to be pumped.*Dimension H is the maximum height of the pump.**Rubber pump 22

    Direct Driven

    8

  • 8/12/2019 k-tech-book 2

    11/14

    Size

    111 / 2221 / 234

    568

    Discharge

    111 / 2221 / 234

    568

    Suction

    221 / 24456

    81012

    A

    281 / 4281 / 4303 / 4303 / 4295 / 8321 / 4

    36401 / 2483 / 4

    B

    81 / 481 / 497 / 897 / 811 1 / 81213 / 16

    141520

    C

    233 / 4233 / 4263 / 8263 / 8267 / 826

    30351 / 840

    D

    7785 / 885 / 897 / 8119 / 16

    121 / 2131 / 2181 / 2

    E

    11 / 411 / 411 / 411 / 411 / 411 / 4

    11 / 211 / 211 / 2

    F

    41 / 241 / 243 / 843 / 823 / 461 / 4

    653 / 883 / 4

    G

    61 / 261 / 28891 / 4107 / 8

    12131 / 2171 / 4

    *H

    2121251 / 8251 / 8271 / 2351 / 2

    393 / 8503 / 4565 / 8

    J

    10101119 / 321119 / 32123 / 4157 / 8

    18183 / 422

    K

    1111131 / 2131 / 2143 / 4195 / 8

    213 / 831**345 / 8

    L

    11 / 211 / 213 / 413 / 431 / 25

    851 / 291 / 2

    M

    51 / 451 / 261 / 261 / 277 / 893 / 4

    11 3 / 8121 / 4133 / 4

    N

    101 / 4101 / 411 3 / 411 3 / 4131 / 215

    151 / 2187 / 820

    O

    45 / 845 / 861 / 461 / 4883 / 4

    89121 / 4

    P

    991111151 / 415

    231925

    Q

    11 / 211 / 213 / 413 / 413 / 421 / 2

    221 / 43

    R3 / 43 / 43 / 43 / 43 / 43 / 4

    7 / 87 / 87 / 8

    S

    21 / 221 / 241 / 841 / 8315 / 169

    91 / 4103 / 8105 / 8

    T

    7781 / 281 / 2611 / 16151 / 4

    151 / 4153 / 4193 / 8

    U

    11 / 811 / 423 / 825 / 841 / 164

    31 / 433 / 843 / 4

    V

    39 / 1639 / 1631 / 1631 / 16313 / 1651 / 2

    71 / 283 / 811 1 / 2

    W

    771 / 287 / 891 / 811 5 / 8141 / 2

    163 / 8167 / 8195 / 8

    X

    17 / 1617 / 16111 / 16111 / 1621 / 823 / 16

    25 / 825 / 833 / 16

    Y

    31 / 431 / 441 / 241 / 241 / 267 / 16

    73 / 1673 / 1685 / 16

    AA3 / 83 / 83 / 83 / 81 / 21 / 2

    5 / 85 / 83 / 4

    AB3 / 163 / 163 / 163 / 161 / 41 / 4

    5 / 165 / 163 / 8

    Dimension P is the minimum clearance for removing wearing parts. Provide ample clearance at this point for removing the wearingparts as they are very heavy.Dimension K is distance from center of pump to outside of discharge sleeve.Dimension N is distance from center of pump to outside of suction flange. the feed may be from either side.Use 1 1/2" pipe sleeves around foundation bolts and allow 1/2" for grouting. Place valves in suction and discharge lines near pump.The suction line should be short, free from elbows if possible, and sloping when heavy materials or large particles are to be pumped.*Dimension H is the maximum height of the pump.**Rubber pump 22

    Bare Pump

    9

    Dimensions in Inches

  • 8/12/2019 k-tech-book 2

    12/14

  • 8/12/2019 k-tech-book 2

    13/14

    Pump

    10L12XL12L

    A

    171 / 4171 / 422

    B

    261 / 4261 / 417

    C

    202031

    D

    232331

    E

    1818235 / 8

    F

    793 / 4793 / 487

    G

    23 / 423 / 42

    H

    51 / 251 / 279 / 16

    J

    183 / 419219 / 16

    K

    241 / 2241 / 2281 / 2

    L

    111171 / 4

    M

    191923 1 / 4

    N

    181 / 2201 / 2211 / 2

    OMin.-Max.

    171 / 2-19 1 / 220-2220-22

    PMin.-Max.

    66-68703 / 4-72 3 / 472-74

    QAve.

    2111 / 162111 / 16231 / 2

    R

    929 / 32929 / 32133 / 16

    SDia.

    33 / 433 / 441 / 8

    Key

    1 / 2 X11 / 2 X11 / 2 X1

    T

    161518

    U

    5858593 / 4

    Suction & Discharge Flange Diameters (125 Lb. Amer. Std.)

    Pump10L12XL12L

    AA141418

    BB10,12,1412,14,16,18,2012,14,16,18,20

    Pump14XL14L16XL

    AA182020

    BB14,16,18, 20,2414,16,18, 20,2416, 18, 20, 24, 30

    L Series

    11

    Dimensions in Inches

  • 8/12/2019 k-tech-book 2

    14/14

    A.R. Wi lf ley & Sons, Inc.

    P.O. Box 2330

    Denver, Colorado 80201

    303/779-1777

    1-800-525-9930

    FAX 303/779-1277

    www.wilfley.com