M1 Installation and User Manual ELECTRIC FENCE MONITOR JVA ELECTRIC FENCE SYSTEMS 2nd Edition, 2013

JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

M1Installation and User Manual

ELECTRIC FENCE MONITOR

JVA ELECTRIC FENCE SYSTEMS2nd Edition, 2013

Page 2: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA

Z E

nerg

izer

Ran

ge C

once

pt

Thank you for choosing our product. The JVA brand is a range of electric fencing products carefully selected from leading manufacturers around the world to meet the needs of perimeter security.

THE JVA Z RANGE ENERGIZER CONCEPTThe JVA Range of Energizers has been collaboratively designed and manufactured by an international team with over 30 years of electric fence experience earned in some of the most testing security environments in the world. It aims to provide the very best low-cost, high-voltage security energizers in the world. They are compact, integrated and fully programmable electric fence energizers with built-in alarm units and LCD out and return voltage display. They also have the option of being controlled from a remote LCD keypad.

State-of-the-art energizer design IP4 x and ABS plastic

Unique LCD display depicting fence out and return voltage

Wall-mountable, robust energizer housing with easily detachable PCB chassis for ease of installation and repair

Unique LCD keypad option depicting fence and alarm condition

TWO-YEAR WARRANTYAll JVA products carry a 2-year warranty against defective

components and workmanship. The warranty excludes damage caused by acts of Nature such as lightning or fl ooding, power

supply surges, rough handling, malicious action or incorrect wiring.

Please retain your invoice as proof of purchase andfi ll in the warranty form on page 32.

2-yrWARRANTY

JVA ELECTRIC FENCE SYSTEMS

Page 3: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

1

Contents

CONTENTS1. INTRODUCTION ....................................................................................... 3

2. FEATURES ................................................................................................ 52.1 Limitations ........................................................................................ 5

3. OPERATION .............................................................................................. 63.1 Control Options ................................................................................ 63.2 Control Arbitration ............................................................................ 6 3.3 Control Inputs .................................................................................. 6 3.4 Keypad Control ................................................................................. 7

3.4.1 Using the Alpha Plus LCD Keypad ..................................... 73.4.2 Changing the USER PIN .................................................... 73.4.3 Changing the Keypad Messages and Address ................... 73.4.4 To Exit Keypad Programming ............................................. 9

3.5 JumperConfiguration ....................................................................... 10

3.6 LCD Display ...................................................................................... 11

3.7 Status LED Lights ............................................................................ 12

3.8 Front Label ...................................................................................... 12

4. SPECIFICATIONS ..................................................................................... 13

5. INSTALLATION ......................................................................................... 14

5.1 8 EHT Terminals on the ZM1 ........................................................... 14

5.2 Fence Wiring Diagrams .................................................................... 15

5.2.1 ConfigurationwithNOReturnWirefromFence ................. 155.2.2 Earth Loop Monitoring ........................................................ 165.2.3 Earth Spike Monitoring ....................................................... 175.2.4 No Earth Monitoring ............................................................ 18

5.3 LowVoltageTerminalsontheZM1 ................................................. 19

5.4 LowVoltageWiringDiagrams .......................................................... 21

5.4.1 16Vac2AmpPowerSupply ................................................. 215.4.2 Controllinga240VacEnergizer .......................................... 225.4.3 External Battery and Charger .............................................. 22

1

Page 4: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

2

Con

tent

s

6. PROGRAMMING OPTIONS ..................................................................... 23

6.1 Programming Basics ....................................................................... 23

6.1.1 Entering Programming Mode .............................................. 236.1.2 Exiting Programming Mode ................................................ 236.1.3 Changing the INSTALLER PIN ........................................... 236.1.4 Changing an Option ............................................................ 23

6.2 Programmable Options Table .......................................................... 24

6.3 Programming Options in Detail ........................................................ 25

6.3.1 FenceAlarmVoltageLevel(01x#) ...................................... 256.3.2 CurrentAlarmLevel(02x#) ................................................. 256.3.3 GroundVoltageAlarmLevel(03x#) .................................... 256.3.4 MissedPulseCount(06x#)................................................. 266.3.5 BatteryAlarmVoltage(07x#) .............................................. 266.3.6 SirenOnTime(08x#) .......................................................... 266.3.7 SirenOffTime(09x#) .......................................................... 276.3.8 SirenCycles(10x#) ............................................................ 276.3.9 InputType(11x#) ................................................................ 276.3.10 Input2Function(12x#) ....................................................... 276.3.11 GateExitDelay(13x#)........................................................ 286.3.12 ChimeMode(14x#) ............................................................ 286.3.13 FenceMode(15x#)............................................................. 286.3.14 BinaryOptions(16x#) ......................................................... 296.3.15 Anti-BridgingThreshold(17x#) ........................................... 296.3.16 AutoRe-ArmTime(20x#) ................................................... 306.3.17 Relay Functions .................................................................. 306.3.18 GroupMode(26x#)............................................................. 31

7. WARRANTY ............................................................................................. 32

Page 5: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

3

1. INTRODUCTION

Introduction

TheZM1isdesignedtobecoupledwithanystandardelectricfenceenergizer(see2.1Limitationsbelow)topowerandmonitoranelectricfence.AsitcancontrolverylargeenergizersitisanticipatedthattheZM1willfindapplicationonlargefencesforgamereservesandbordersecurity.TheZM1usesPatentPending,DFD™ technology to determineifthereisafaultonverylongfences.

ThecombinationoftheZM1andtheenergizeroperateinthesamewayasasingleJVAZseriesenergizer,withtheexceptionthatthepulsepowerleveloftheenergizercannotbemodified.

TheZM1monitorsthelivefeedlinefromtheenergizertothefenceanddeterminesifthefenceisworkingproperlybymeasuringthevoltageandcurrent(thereforepower)flowing to the fence. As such it does not require a return line from the end of the fence.Thiscanrepresentalargesavingoninstallationcostsonnewfencesormakemonitoringanexistingfencepossibleifnoreturnlinewasoriginallywired.TheZM1can,however,alsomonitorthereturnifthatisdesired.

TheZM1hasmanyprogrammableoptionswhichcanbeadjustedusingaJVAZserieskeypad.Bycorrectlysettingthealarmthresholdlevelsitispossibletodetermineifafencehasbeencutorshortedatanypoint.

TheZM1isdesignedtomeetorexceedtherelevantpartsof IEC60335.2.76.TheZM1ispartoftheJVAZseriesofsecurityenergizers,designedandmanufacturedby Pakton Technologies.

Page 6: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

4

Intr

oduc

tion

Equipment Requirements and Options

Requirements• Anenergizer• 12Vrechargeablebackupbattery• 16VacpoweradaptorORexternalbatterycharger• Securityelectricfence;standards,insulators,wireetc.

SomeoftheseitemsmaybeincludedwiththeZM1.

Options• 12VSirenandstrobelight• LCDKeypad(PTE0210).Note1,2• WindowsPC

– WindowsXPorWindows7– PAE223 USB to Keypad Bus or PAE212 TCP/IP adaptor– PerimeterPatrolPCapplication(Proversion)

Notes:1. WhiletheKeypadisnotessentialfornormaloperation,itisalwaysrequiredfor

programming options during installation.2. Upto3KeypadsmaybeusedwithaZM1,eachKeypadmusthaveauniqueID

setting.

Formoreinformationontheseoptionspleaseseewww.jva-fence.com.au

TherearehighvoltagesinsidetheZM1andJVAenergizers.

The high voltage inside the energizer may take a longtimetodischarge.Waitatleast10minutesafterturningoffbeforeopeningthecase.

Beforeworkingon thehigh voltagewiringof anelectricfence, it is recommended that theenergizer isdisarmedandashortcircuit isplaced fromthe fence livewires toearth.This is a sensible precaution against the energizer being armedwhileworkingonthefence.

Note: The energizer manual must also be provided to the customer as itincludesmandatorysafetyinformation.

DANGER

TheZM1containspatentpendingtechnology.contactJVAformoreinformation.

Page 7: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

5

Features

2. FEATURES

• Wall-mountableZseriesenergizerenclosure• Canbecombinedwithanyenergizer(see2.1Limitationsbelow)toproduceafullfeaturedsecurityelectricfenceenergizer/monitor

• DistantFaultDetection(DFD)™allowsfaults tobedetectedonvery longfencelines(Note1)

• Anti-bridgingmode,alarmsonsuddenchangeinload(Note2)• ControlandprogrammableviakeypadwithsimilarcodestotheZseries• Monitorfencevoltageandcurrenttotriggeranalarmifcurrentrisesorvoltagefalls(loadincreases)

• Startand/orendoffencemonitoring• AbletobemonitoredviaPC(usingZcontrolorPerimeterPatrolsoftware)• Runfrom16Vacor12VDCexternalsource• Built-inbatterychargerand7aHback-upbattery(notincluded)asperZ14• Canbeoperatedfromalternativelargerexternalbatteryandcharger• Controls12VDCfeedtoenergizer• Cancontrola240Vacenergizerviaexternalrelay(notsupplied)(12Vcoil,240Vacratedcontacts)

• Remoteon/offorkeyswitch• Gatecontactinput• Sirenandstrobeswitched12VDCoutputs• 3on-boardrelayswithmanyprogrammablefunctions.

2.1 Limitations• An energizer used with the ZM1must comply with IEC60335.2.76 (or similar)safetystandard.

• TheZM1supportsconventionalwiringonly(notBi-Polar),although2unitscouldbeusedtomonitoraBi-Polarfence.

• Themaximumenergizerpoweris36Joules(StafixM36orsimilar).• Atthisstage(CodeVersion1.4andearlier)aZM1cannotbeusedinagroupeitherwithotherZM1unitsorwithZseriesenergizers.

Notes:1. DFDoperatesonPCBVersions1.1andhigherandfirmware1.40andhigher.2. Anti-bridgingoperateswithfirmware1.32orhigher.

Page 8: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

6

Ope

rati

on

3. OPERATION

3.1 Control OptionsTheZM1maybearmedanddisarmed(controlled)usinga:

• Keyswitchorremoteswitchconnectedtothecontrolinput(IN1)• RemotecontrolradioreceiverconnectedtoIN1• ZSeriesKeypad• JVAGSMmodule• WindowsPCrunningJVAPerimeterPatrol(Proversion)• Lowlevelinterface(wiredtocontrolinputsandrelayoutputs)fromathirdparty

securityalarmpanelorPhysicalSecurityInformationSystem(PSIM)• Ahighlevelinterface

NOTE: More than 1 method may be used in the one installation.

3.2 Control ArbitrationIfaninstallationcontainstwowaystocontroltheZM1/Energizer,thenthemostrecentcontrolsignalwilldeterminetheArmed/Disarmedstate.Forexample,iftheZM1isarmedviathekeypad,andthendisarmedatthecontrolinput(IN1),itwilldisarm.

Thehigher levelcontrolmethodssuchas theGSMandPCcontrol softwaremayoverridetheControlinputandKeypadsmethods,dependingontheoptionsused.Ifyouneedtomakesurethatthefenceisdisarmed(formaintenance)thenusingtheKeyswitchorkeypadalonemaynotguaranteethatthefencewillremaindisarmed.

3.3 Control Inputs The ZM1 may have a single Key switch mounted on the right hand side of thecabinetwhichmaybeusedtoarmanddisarmthesecurityelectricfencetowhichitisconnected.ThisswitchisusefulforthesimplestimplementationswherenokeypadorPCcontrolprogramisused.Itmaybedisabledbytheinstaller,byremovingtheleadfromsocketSW2.

Whenswitchedonvia theKeyswitch(oraswitchconnected to IN1) theZM1willpoweruptheenergizeritiscoupledtoandbeginmonitoringthefence.

TheLCDdisplaywillchangetodisplaytheFeedandGroundvoltages.IfthereisafencefaulttheZM1willgointoalarm,theinternalbeeperwillsound(ifithasnotbeeninhibited)andanysirenandstrobeconnectedtotheZM1willbeturnedon.

SwitchingtheKeyswitchoffwilldisarmtheZM1,thoughitwillcontinuetodisplaythe alarm.

Page 9: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

7

Operation

3.4 Keypad ControlThe ZM1 uses the same keypads as the Zseriesenergizersand is controlledusingthe same keypad codes outlined below.The keypad will also display the feed andreturn voltages of the fence, but not theground voltage or fence current at this time.The standard alarms and alerts to problems (Trouble)willalsobedisplayed.

3.4.1 Using the Alpha Plus LCD KeypadTheLCDkeypadhastwoLED’s,Power and Arm,whichactasfollows:

Power – Onwithmainspower,flashesonlowbatteryArm – OnwhentheZM1isarmed.

Allotherindicationisgivenviamessagesonthescreen.

Wheneverthekeypaddisplays:

• ALARMZONE• FAULTEDZONEor• SYSTEMTROUBLE

pressingthe[#]keywillrevealmoreinformation,suchasthenameofthezoneortheactualsystemtrouble,forinstanceACFail.

3.4.2 Changing the User PINEntertheoldUSERPINfollowedby*0#(star,zero,hash).Enternew4-digitUSERPINand#(hash).

3.4.3 Changing the Keypad Messages and Address Youcanchangethemessagesandeachofthe8zonelabels.

The Dealer Messagedisplayswhenthesystemisonstandby.

Zonelabelsdisplayafterthe[#]keyispressedduringalarmmemoryorfaults.

The programmable Service Message is displayed duringAC failure, fuse failure,communicationfailure,orlowbattery.

Page 10: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

8

Keys used for changing messages

[1] [2]Characterup [3]notused Emergency not used

[4]<-Cursorleft [5]NextMessage [6]->Cursorright Fire not used

[7] [8]Characterdown [9] Panic not used

[*] [0]LastMessage [#]Enter/Exit Bypass not used

• Toactivatethekeypadprogrammingmode,enterthe[INSTALLER’sPIN][*][0][1][#].Informationmaybeenteredintothekeypadintheformofletters(upperandlowercase),numbers(0–9),and22specialsymbols.Allcharactersaredisplayedin theorder: upperand lower case letters, numbers, andspecial symbols.The[Space]characterprecedestheletterA.

• ToenteraLabel,usethe[2]keytoscrollthroughthecharactersuntilyoureachthedesiredcharacter.Ifyouscrollpastthedesiredcharacter,the[8]keymaybeusedtoscrollbackwards.Note:ThespacecharacterisbeforetheAcharacter(WhenAisdisplayed,press[8]tocreateaspace).

• Whenthedesiredcharacterisdisplayed,pressthe[6]keytomovethecursortothenextcharacterposition.The[4]keymovesthecursortotheleft.

• Whenallcharactershavebeenentered,pressthe[#]keytoenterthemessageandmovetothenextmessageposition.

• Usethe[0]keytomovebackwardthroughthemessages.

• To change the keypad address, scroll through the messages until the keypaddisplays: Keypad Address thenchangethevaluebypressing[2](up)or[8](down).Validatebypressing#

Note:Ifyoumovetothenextmessageusing[5]insteadofthe[#]key,youwilllose any changes you made!

Notes on keypad addresses: Upto3keypadscanbeusedinasystem.Whenusing2or3keypadsinasystem,oneof the keypadsMUSTbe set toaddress2and the secondone shouldbesettoavaluebetween1–7.Donotsetthistoaddress8asthisaddressusesadifferentprotocol.Ifathirdkeypadisused,itsIDmustalsobesettoauniquevaluebetween1and7.

the message order is:

• SERVICEMESSAGE(DisplayedunderSYSTEM TROUBLE)• DEALERMESSAGE(Displayedunderthestandbymessage:READY TO ARM)• SOFTZONEIDENTIFIERS(A,B,andC)(notused)• HARDWIREDLOOPIDENTIFIERS(Zone 1 =Gate,Zone 3 =Fence)• KEYPADADDRESS(shouldbe leftat1 forenergizerswithfirmwareolder than7V51)

Ope

rati

on

Page 11: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

9

3.4.4 to exit Keypad ProgrammingWhenyouhavefinishedprogramming,press[*][#]

Note:Thekeypadwillalsoexittheprogrammingmodeifyoudonotpressanykeywithinafiveminuteperiod.

summary of LCD Keypad Functions

Function Key sequenceArm/Disarm [UserPIN][#]Silenceanalarm(singlezonesystemonly) [UserPIN][#]StartprogrammingtheZseriesenergizer [InstallerPIN][*][0][#]Start programming the keypad [InstallerPIN][*][0][1][#]Exitprogramming(anymode) [*][#]Change a USER PIN [UserPIN][*]0[#][NewPIN]#Change the INSTALLER PIN [0][0][NewInstallerPIN][#]Arm All Zones(multi-zonegroups) [UserPIN][*][1][0][#]Arm Zone 1(Master) [UserPIN][*][1][1][#]Arm Zone 2(onZ28orSlaveingroup) [UserPIN][*][1][2][#]Disarm All Zones [UserPIN][*][2][0][#]Disarm Zone 1 or Master [UserPIN][*][2][1][#]Disarm Zone 2(onZ28orSlaveingroup) [UserPIN][*][2][2][#]Switchtolowpowermode(allzones) [UserPIN][*][4][1][#]Switchtohighpowermode(allzones) [UserPIN][*][4][2][#]

To change the Keypad Messages to English [*][3][1][#]To change the Keypad Messages to Spanish [*][3][2][#](notwellsupportedyet)

Keypad Audible Feedback Toggle [*][5][1][#]KeypadAlarmBeeper(Chime)On/Off [*][5][3][#]KeypadErrorTonesToggleOn/Off [*][5][4][#]BacklightToggleOn/Off [*][8][#]Display Keypad Model [*][9][#]Resetanddisplayfirmwareversionnumber [UserPIN][*][6][8][#]PowerBoost [*][9][9][#]Siren test [*][6][3][#]Battery test [*][6][4][#]onlywhiledis-armedClear Alarm memory [*][1][#]

Proposed Function Proposed Key sequencePre-warntoggleon/off [*][5][2][#]Resetandreturntofactorydefaults [InstallerPIN][*][6][8][#]Emergency Holdfor3seconds.

Operation

Page 12: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

10

Ope

rati

on

3.5 JumperConfigurationTheZM1isequippedwithfourjumpers.Twoofthem(J3andJ4)arespecialpurposejumpers(links).Thepurposeofeachislistedinthetablebelow.

Jumper Function PurposeJ3 DConlyjumper RemoveJ3toinhibitmainsfailerrorsifthe

intentionistooperatetheZ14onDConly(asinSolarPowersystems)

J4 Factorydefaultjumper Ifthemonitorunitneedstobedefaultedtofactorysettings,removeallpower–mainsandbattery–andremovetheJ4jumper.Reapplythebatterypowerfirst,andthenthemainspower.ReapplytheJ4jumperandtheunitwillberesettodefaultsettings.IfStatus LED flashesfourtimesafterdefaultingtheunit,returnittothenearestJVAservicecentre.

The3rdjumper,J5,whenfitted,willsuppressthebeeperontheZM1.

Thefourthjumper(J6)allowsthesupplyvoltagefortheenergizertobeset.Ifthetoptwopinsareselected(12VRegulated)thentheenergizersupplyvoltagewillbethesameasthePAE202batteryvoltage(between12and14.5volts).Ifthebottomtwopinsareselected(24VUnregulated)thevoltagesuppliedtotheenergizerwilldependonthetypeandsizeofACpoweradapterused,butmaybeashighas24volts.

Page 13: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

11

3.6 LCD Display TheLCDdisplayontheZM1willswitchbetweentwodifferentdisplaymodes.ThemodeshowncanbeidentifiedbythefeedandreturnLED’sonthestatuspanel.

Thepictureontheleftbelowshowsthefeedmode,whichshowsthevoltageatthestartof the fence,and thecurrent flowing into the fence.Thepictureon the rightshowsthevoltageattheendofthefence,andthegroundvoltage.

Notethatthereturnvoltagecanbeinhibitedwithprogrammingoption15ifonlythestartofthefenceistobemonitored.

OPERATION

Keypad Control

Group Configuration

Jumper Configuration

LCD display

OPERATION

Keypad Control

Group Configuration

Jumper Configuration

LCD display

Operation

Page 14: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

12

Operation

3.7StatusLEDLightsThestatusLED’sonthefrontoftheZM1allowtheusertoquicklyascertainthecurrentstatusoftheunitandifanyactionneedstobetaken.BelowisabriefdescriptionofeachLED(fromlefttoright,toptobottom)andtheinformationitconveys.

Power – OnwhenevertheunithaspowerFeed – Tells the user that the LCD is displaying the Feed Voltage(left)andFence

Current (right)Armed – Onwhentheunitisarmed(pulsing)Return – Tells the user that the LCD is displaying the Return Voltage (left) and

Ground Voltage (right)Fence – Onwhenthereisafencealarm(eitherchannel)Gate – OnwhenthereisagatealarmGround – Onwhenthereisagroundalarm(specificmeaningwillvarydepending

ongroundconfiguration)(Pleaserefertotheinstallationchapterformoreinformation.)

Status – Flashesanerrorcodeformonitor(service)errors.TheseerrorcodesareidenticaltotheZenergizerrange.ThetablebelowshowstheStatusLEDError Codes.

error LeD Number of Flashes Interpretation Corrective Action

2 16Vacmainsfail Restoremainspower3 Lowbattery,badbattery Charge or replace battery

4PCBservicefault Returntorepair/servicecentre.

Note:AZslavewillshowthiserrorifdisconnectedfromtheMaster.

3.8 Front LabelAscanbeseeninthepicturealongside, thefrontlabelclearlylabelsthedifferent LEDfunctionsandLCDdisplaymodes.

Spe

cific

ations

Spe

cific

ations

Ope

rati

on

Page 15: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

13

Operation

Spe

cific

ations

4. SPECIFICATIONS

ThespecificationstablebelowoutlinesthepowerconsumptionoftheZM1andtheacceptablevoltageandcurrentrangesfordifferentinputsandoutputs.

Internalbatterychargerfloatvoltage 14.3VdcInternal battery charger charging current 580mAAbsolutemaximumpowerconsumptionofZM1(Note1) 85mAat12.5VdcMaximumACinputvoltagewheninternalbatterychargerissupplying 580mA 19Vac

MaximumDCenergizercurrentfromENERGIZERpoweredoutputifusing16Vacsupplyandinternalbattery 2.3 Amps

AmpsmaximumDCenergizercurrentfromENERGIZER poweredoutputifusingexternalpowersupplyandbattery 10 Amps

MaximumvoltageonIn1,SW2 and Gateinputs(Note2) 5VdcMaximumpowerprovidedtoSiren and Strobe outputs (Note3) 35Watts

Maximumfencevoltage 9.9kVMaximumfencecurrent 80 AmpsRecommended operating temperature –15°C to +50°C

Note 1: This is the power consumption when none of the powered outputs areactiveandthekeypadisnotconnected.Theratedpowerconsumptionmaybelowerdependingonrelayconfigurationandalarmstates.

Note 2: The control inputs, In1,SW2 and Gate supply their own power (5 volts,limited to 220nA). If a powered control system is connected to these inputs, thecontrolvoltagesmustnotexceed5volts.

Note 3:TheratedpoweristhecombinedoutputpowerofboththeSiren and Strobe outputs.Thevoltagewhichcanbeexpectedonthisoutputisthebatteryvoltage.Thecombinedmaximumoutputcurrentofboththeseoutputsis2.5Amps.Notethatthemaximumoutputpowerwilldropasbatteryvoltagedrops.

Spe

cific

ations

Specifications

Page 16: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

14

5. INSTALLATION

5.1 EHTTerminalsontheZM1

INSTALLATION

EHT terminals on the ZM:

Description of high voltage terminals (left to right)

EHT In Connectthehighvoltageoutputoftheenergizertothisterminaltoallowfencecurrenttobemeasured.

Feed Connectthestartofthefencetothisterminal.VoltageatFeedwillbethesamevoltageasEHT In.

Return Connecttheendofthefencetothisterminal.TheReturn voltagewillnormallybelowerthantheFeed voltage.

Not Used This terminal is unused at this time.GroundRef Referencegroundconnection.PleaserefertodiagramsEarth Loop

Monitoring,Earth Spike Monitoring and No Earth Monitoring forinformationonhowtoconfigurethisinput.

Ground Mainfenceearth.PleaserefertodiagramsEarth Loop Monitoring,Earth Spike Monitoring and No Earth Monitoringforinformationonhowtoconfigurethisinput.

Inst

alla

tion

Page 17: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

15

ENERGIZER

5.2.1 ConfigurationwithNOReturnWirefromFenceNote:PleaserefertoprogrammingoptionFenceMode(point6.3.13)onpage28.

5.2 FenceWiringDiagramsThereareanumberofwaysthefencewirescanbeconnectedtoaZM1.Thefollowingdiagramswilloutlinedifferentwaysinwhichthegroundcircuitcanbeconfiguredandwhatthebenefitsofeachare.

EARTH SPIKES

JVAKEYPAD

JVAZM1

M36

HVIN

FEE

D

GR

OU

ND

RE

F

Installation

Page 18: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

16

5.2.2 earth Loop MonitoringThesetuppicturedbelowwilldetectifthegroundwirehasbeencut.ConnecttheGround ReferenceinputtotheenergizerEarth,andtheGround input to the other end oftheearthfenceloop.

Inst

alla

tion

HIGHVOLTA

GEIN

FEE

DHIGHVOLTAGE

ENERGIZER EARTH

HIGH POWER ENERGIZER

Feed/ Return

RE

TUR

N

GR

OU

ND

RE

FER

EN

CE

GR

OU

ND

EARTH

Current/ GroundkV

CONVENTIONALFENCE

Page 19: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

17

Installation

5.2.3 earth spike Monitoring This setup will check how well the energizer is earthed. Connect the Ground ReferenceinputoftheZM1tothemainsearth,orthecabinetearth.ThisGroundReferencemustbemorethan10mawayfromtheEnergizerEarth.

HIGHVOLTA

GEIN

FEE

DHIGHVOLTAGE

ENERGIZER EARTH

HIGH POWER ENERGIZER

Feed/ Return

RE

TUR

N

GR

OU

ND

RE

FER

EN

CE

GR

OU

ND

EARTH

Current/ GroundkV

CONVENTIONALFENCE

Page 20: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

18

5.2.4 No earth Monitoring Thissetupwillmonitoronlythefencefeedandreturnvoltagesandfencecurrent.Connect the Ground Reference and Groundinputstoeachotherwithashortpieceofwire.

Inst

alla

tion

HIGHVOLTA

GEIN

FEE

DHIGHVOLTAGE

ENERGIZER EARTH

HIGH POWER ENERGIZER

Feed/ Return

RE

TUR

N

GR

OU

ND

RE

FER

EN

CE

GR

OU

ND

EARTH

Current/ GroundkV

CONVENTIONALFENCE

Page 21: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

19

Installation

5.3 LowVoltageTerminalsontheZM1

Low voltage terminals on the ZM1

Label Type Description Energiser control input (dry contact). Defaults to normally open.

Can be used for a remote switch or a radio receiver. The receiver may be powered from the keypad +12V terminal.

Seepage20foratablegivingtheTypeandDescriptionofeachcomponentlabelledabove.

Page 22: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

20

Inst

alla

tion

Label type DescriptionIN1 2 Way Energizercontrolinput(drycontact).Defaultstonormally

open.Canbeusedforaremoteswitchoraradioreceiver.Thereceivermaybepoweredfromthekeypad+12Vterminal.

Gate 2 Way ZM1GateInput,whentheunitisarmedandthegateisopened,itwilltriggerthegatealarm.

Keypad 3 Way Suppliespoweranddatalineforanexternalkeypad.The+12sourceontheseterminalsisprotectedwitha1Aselfresettingfuse.

Siren 2 Way Switched12voltoutput.Lowsideswitched.35Wmax(includingstrobe).Abufferrelayshouldbeusedwhenconnecting these outputs to an alarm panel.

Strobe 2 Way Switched12voltoutput.Lowsideswitched.35Wmax(includingsiren).Abufferrelayshouldbeusedwhenconnecting these outputs to an alarm panel.

EnergizerPower

2 Way PoweredoutputwhichisenabledwhentheZM1isarmed.PowerisdrawnfromtheZM1batteryand16Vacpowersupply,orfromtheEXT12Vinput.

EXT12V 2 Way InputusedforDCenergizerswhichexceedthesupplyratingofthe16Vactransformer(greaterthan12Joulesoutput).

16VACIN 3 Way 16Vacpowerinput.FusedviaF33Aselfresettingfuse.Relay 3 3 Way Maybesettoanyof16alarmconditions.Relay 4 3 Way Maybesettoanyof16alarmconditions.Relay 5 3 Way Maybesettoanyof16alarmconditions.Batt Leads 12VdcorbatteryconnectionviaF1(3Ampselfresetting

fuse).ConnectRedleadtobatterypositive(+)terminal.(notpicturedonpage17)

SW2 2 Way Energizercontrolinput.Normallyconnectedtoakey-switch(notpicturedonpage17).

Page 23: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

21

Installation

5.4 LowVoltageWiringDiagrams

5.4.1 16Vac2AmpPowerSupply

HIGHVOLTAGE

HIGH POWER ENERGIZER

EARTH

Feed/ Return

Current/ GroundkV

12V 16Vac

BATT

16Vac 2A PSU

SLA12Volt Battery

+ -The ZM1 can be used to power an external highpowered energizer. A 16Vac 2Amp power supplyis able to power a B5, B8 or B12 (or equivalent)energizeraswellastheZM1andkeepthebackupbattery charged.

WARNING: The DC voltage supplied to theenergizerwillbe therectifiedvoltageof the16Vacwhichmaybeashighas30Vdc.

Largerenergizerswillneedtoutilisetheexternal12voltpowersupplyinput.

Page 24: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

22

5.4.2 Controlling a 240Vac energizer

HIGHVOLTAGE

HIGH POWER ENERGIZER

EARTH

Feed/ Return

Current/ GroundkV

12V 16Vac

BATT

16Vac 2A PSU

SLA12Volt Battery

+ -

Mains Relay Box

110/240Vac Input

TheZM1canbeusedtopoweranexternalhigh-poweredenergizer.

The ZM1 can control an external relay box designed to switch110Vacor240Vacpoweredenergizers.Therelayboxneedstoacceptswitchingvoltagesofupto13.8volts.

WARNING:DONOTuserelay3,4or5ontheZM1toswitchmainsvoltage.

Inst

alla

tion

5.4.3 external Battery and Charger

Larger12Vdcenergizerswillneedtoutiliseanexternal12voltpowersupply.

To power the ZM1 from theexternal battery and charger,ensure Jumper J6 is placed on the 12V regulated pins. Do notconnecta16Vacsupplytothe ZM1.

HIGHVOLTAGE

HIGH POWER ENERGIZER (DCPOWERED)

EARTH

Feed/ Return

Current/ GroundkV

BATT

External 13.8Vdc Charger

SLA12Volt Battery

+ -

12V 16VacOUT IN

12V

Page 25: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

23

Program

ming O

ptions

6. PROGRAMMING OPTIONS

LiketheZseriesofsecurityenergizers,theZM1hasanon-volatilememoryinwhichprogrammingoptions(orsetupparameters)canbestored.Thesearefactorypre-set,butcanbefieldprogrammedusingakeypad.

6.1 ProgrammingBasicsSomeoftheprogrammingoptionsontheZM1aredifferenttothoseontheZseriesofsecurityenergizers,butthebasicfunctionsremainthesame.

6.1.1 entering Programming ModeToenterprogrammingmode,enterthe6digitINSTALLER PIN followedby*0# keys. Thekeypadwillbeeptwicetoindicatethatthecommandwasaccepted.IfthePINwasincorrectthekeypadwillbeep3times.TheLCDwillnowshowthefirstprogrammingoption and its current setting.

Pressingthe#keywillcyclethroughalltheoptionsontheLCD.

Note:Notallnumbersareused.ThedefaultINSTALLER PIN is 012345.

6.1.2 exiting Programming ModeToexitprogrammingmodeonceprogramminghasbeencompleted,press*#.Ifleftunattended,theunitwilltimeoutandautoexitafterapproximately5minutes.

6.1.3 Changing the INstALLer PINThe INSTALLERPINmayonlybechangedwhileinprogrammingmode.

ToenteranewINSTALLER PIN,press00 followedbythenew6digitINSTALLER PIN,thenthe# key.

If youcannot rememberyour INSTALLER or USER PIN, return theunitsmemorytodefault.Todothis,removepower(ACoffanddisconnectthebattery),opentheenergizer,removejumperJ4andreconnectthebatteryforabout10seconds.Donotforgettore-fitJ4.Thiswillreturnalloptionstothefactorysetdefaults.

6.1.4 Changing an optionMostoftheoptionshavepossiblevaluesintherangeof0to9.

Tochangeanyoptions,firstcheck theoptionnumber (see tableonpage24)andthen the Programming Options in Detail on page 25. Then press the option number followed by the required value. For example, to change theMissed PulseCount(Option06)tomaximum(9istheMaximum)press069#,thekeypadwillbeeptwicetoindicatethatthecommandwassuccessful.TheZM1LCDwillimmediatelyshowtheupdatedvalue.

Page 26: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

24

Pro

gram

min

g O

ptio

ns

6.2 ProgrammingOptionsTable

option Function Description01 Fence alarm

voltagelevelSetsthevoltagebelowwhichthefencealarmwilloccur.IfthefeedORreturnvoltagefallsbelowthislevelformorethantheMissed Pulse Count afencealarm(Zone 1)willoccur.Ifthereturnvoltageisnotbeingusedsetoption15to1.

02 Current alarm level

Setsthethresholdtoalarmoncurrentfromthefeedterminaltothefence.Ifthefeedcurrentrisesabovethislevelformorethan the Missed Pulse Countafencealarm(Zone 1)willoccur.

03 Ground Voltagealarmlevel

Sets thevoltageabovewhich the fencealarmwilloccur. Ifthegroundvoltagerisesabovethis level formorethantheMissed Pulse Countagroundalarm(Zone 2)willoccur.

06 Missed Pulse Count

Setsthenumberofpulseswhichmaybemissedbeforethealarmisactivated.

07 Battery Alarm Voltage

Sets thebatteryvoltage thresholdbelowwhich thegeneralalarmwillactivate.

08 Siren On Time Setsthetimethatthesiren(andkeypadbeeper)willstayonafteranalarm.

09 SirenOffTime TheamountoftimethesirenwillremainoffaftertheOn Time has expired.

10 Siren Cycles The number of times the siren will sound for the time setin On Time above. After this many cycles the siren willautomatically mute.

11 Input type AllowstheZM1inputstobechangedfromnormallyopentonormally closed.

12 Gate Input Function

Gateswitchonlyfornow.

13 Gate Exit Delay

Durationoftimefromgateswitchopeningtoalarm.

14 Chime Mode Allowsthekeypadandinternalbeeperfunctiontobealtered.15 Fence Mode Setto1ifusingstartoffenceonly,removesreturnvoltage

fromdisplayandalarm.16 Binary Options Miscellaneous options17 Anti-Bridging Sets the% threshold for alarmon a sudden rise or fall of

fencecurrent.20 Auto Re-Arm

TimeSetsthetimewhichmustelapseafteranalarmhastimedout(completedthesirencycles)beforetheunitwillautomaticallyre-armreadyforthenextalarmevent.

21 Relay 1 Usedtoassignanalarmfunctiontorelay1(sirenoutput)22 Relay 2 Usedtoassignanalarmfunctiontorelay2(strobeoutput)23 Relay 3 Usedtoassignanalarmfunctiontorelay324 Relay 4 Usedtoassignanalarmfunctiontorelay425 Relay 5 Usedtoassignanalarmfunctiontorelay526 Group ID IfusedaspartofaSCADAsystem,thissetsthedeviceID

Page 27: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

25

Program

ming O

ptions

6.3 ProgrammingOptionsinDetail

6.3.1 Fence Alarm Voltage Level (01x#)Thisoptionsetsthevoltagebelowwhichthefencealarmwilloccur.IfthefeedORreturnvoltagefallsbelow this level for more than theMissed Pulse Count afencealarm(Zone 1)willoccur.Ifthere-turnvoltageisnotbeingused,setoption15to1.

Unlike the other Z series energizer the value issetdirectly,notviaa table.Forexample tosetathresholdof5.0kVenter:0150# (Donotenterthedecimal!)Thedefaultlevelis4.0kv(40).

6.3.2 Current Alarm Level (02x#)This option sets the threshold to alarm on current from the feed terminal to the fence. If the feedcurrent rises above this level for more than theMissed Pulse Count a fence alarm (Zone 1) willoccur.

Unlike the other Z series energizer, the value issetdirectly,notviaa table.Forexample tosetathresholdof5Aenter:0205#Thedefaultlevelis10A.

6.3.3 Ground Voltage Alarm Level (03x#)Thisoptionsetsthevoltageabovewhichthefencealarmwilloccur.IfthegroundvoltagerisesabovethislevelformorethantheMissed Pulse Count a groundalarm(Zone 2)willoccur.

Unlike the other Z series energizer, the value issetdirectly,notviaatable.Forexample, tosetathresholdof2.0kVenter:0320#Do not enter the decimal! Thedefaultlevelis1.0kv(10)

Value (x) Alarm LevelMinimum0 0.0kVMaximum99 9.9kVFence Alarm Voltage Level

(01x#)

Value (x) Alarm LevelMinimum0 0 AmpsMaximum75 75 AmpsCurrent Alarm Level (02x#)

Value (x) Alarm LevelMinimum0 0.0kVMaximum50 5.0kVGround Voltage Alarm Level

(03x#)

Note: The bold panel in each table indicatesthedefaultvalue.

Page 28: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

26

Pro

gram

min

g O

ptio

ns

Value (x) Missed Pulses

0 11 12 23 34 45 56 67 78 89 9

Missed Pulse Count (06x#)

6.3.4 Missed Pulse Count (06x#)The Missed Pulse CountoptionisidenticaltothatoftheZseriesofsecurityenergizers.

Thisoptionenablesthepulsecounttobevariedfromthedefault(3).Thisisthenumberofbadormissingpulsesthatarecountedbeforethealarmoccurs.

Note:The lower this option is set, themore likelyyouaretogetfalsealarms

6.3.5 Battery Alarm Voltage (07x#)Thisoptionsetsthebatteryvoltagethresholdbelowwhich the general alarm will activate. The defaultBatteryAlarmVoltage is10.0Volts.Thisalarmcanbesettoactivateoneoftherelays,andispartoftheGeneralalarm,seebelow.

Note:TheZM1willnotturntheenergizeroffwhenthe battery voltage is low.But if the supply voltagefallstoolowtherelaypoweringtheexternalenergizerwilleventuallydropout.

6.3.6 siren on time (08x#)The Siren On Timeoption is identical to thatof theZseriesofsecurityenergizers.

Thisoptionsetsthedurationoftimethatthesirenwillremainonafterafencealarmoccurs.Afterthistimethesirenwillturnofffortheoff time indicated in the table in 6.3.7 Siren Off Time Values.Thesirenwillsoundagainifthealarmisstillpresentafterthisoff time has passed.

The default is 3Minutes. Thismay be the subjectof localregulationstostopanalarmcausingunduedisturbancetoneighbours,etc.

Note: The Siren On Time will be cut short if thebatteryfallsbelowthelowbatterylevel.

Value Alarm0 9.0V1 19.5V2 10.0V3 10.5V4 11.0V5 11.5V6 12.0V7 12.5V8 13.0V9 13.5V

Battery Alarm Voltage (07x#)

Value time0 10 Seconds1 30 Seconds2 1 Minute3 2 Minutes4 3 Minutes5 4 Minutes6 5 Minutes7 6 Minutes8 7 Minutes9 8 Minutes

Siren On Time (08x#)

Page 29: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

27

Program

ming O

ptions

Value time0 10 Seconds1 1 Minute2 2 Minutes3 5 Minutes4 10 Minutes5 20 Minutes6 30 Minutes7 40 Minutes8 50 Minutes9 60 Minutes

Siren On Time (09x#)

6.3.7 siren off time (09x#)The Siren Off Time option is identical to thatof theZseriesofsecurityenergizers.

Thisoptionsetstheamountoftimethesirenwillbeoffforaftertheontimeabovehasexpired.Ifanalarmisstillpresentafterthisoff timethesirenwillsoundagain.

6.3.8 siren Cycles (10x#)The Siren Cyclesoption is identical tothatof theZseriesofsecurityenergizers.

Thisoptionsets themaximumnumberof timesthesirenwillsoundfortheOn Timeifthealarmcontinues.This may be limited by local regulations to stop an alarmcausingunduedisturbancetoneighbours,etc.

Note:Thisisthemaximumnumberofcyclesfor1continuous alarm. Intermittent alarm events couldcausemorethanthisnumberofsirensoundings.

6.3.9 Input type (11x#)The Input Type option is identical to that of theZseriesofsecurityenergizers.

ThecontrolinputscanbeinvertedunlessaninputisusedforaGateswitch,inwhichcaseitisalwaysNC.

6.3.10 Gate Input Function (12x#)ThisinputcannotbeconfiguredtoanythingotherthanaGate input at this time.

Value Cycles0 11 12 23 34 45 56 67 78 89 9Siren Cycles (10x#)

Value Input type0 No Normally

open1 NC Normally

closedInput Type (11x#)

Page 30: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

28

6.3.11 Gate exit Delay (13x#)The Gate Exit DelayoptionisidenticaltothatoftheZseriesofsecurityenergizers.Thisoptionsetsthetimebetweenthegateswitchopeningandthesirensounding.

6.3.12 Chime Mode (14x#)The Chime Modeoption is identical to thatof theZseriesofsecurityenergizers.

Thisoptionallowstheenergizerinternalandkeypadbeeper to be used as a door chime for the gateswitch. When set to None, the keypad beeper isused to indicate correct keypad operation only. In Door Chime mode, the beepers sound when thegateswitchopens,eveniftheenergizerisdisarmed.Note: Gate must be selected in option 12.

IfsettoSiren,thebeepersmimicthesirenfunction.

Gate Beeps plus Siren will give 2 beepswhen thegatestartsopeningand4beepswhenitcloses,pluscontinuous beeps for an alarm. Beeps are on thekeypadonly,notontheinternalbeeper.

6.3.13 Fence Mode (15x#)Thisoptionconfiguresifthereturnvoltageshouldbemonitored.Ifsetto1,thisoptionwillstopthereturnvoltagefrombeingdisplayedontheLCD,andinhibitanyalarmswhichmaynormallybetriggeredowingtonovoltagebeingpresentonthereturninput.

Pro

gram

min

g O

ptio

ns

Value Function0 0 Seconds

(immediate)1 30 Seconds2 1 Minute3 2 Minutes4 3 Minutes5 4 Minutes6 5 Minutes7 6 Minutes8 7 Minutes9 8 Minutes

Gate Exit Delay (13x#)

Value Function0 None1 Door Chime2 siren3 Fence Alarm4 Gate Beeps

plus SirenChime Mode (14x#)

Value Function0 Monitor return1 Feed onlyFence Mode (15x#)

Page 31: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

29

Program

ming O

ptions

6.3.14 Binary options (16x#)Each option in this table can be turned on by adding thevalue.Foroption+1set16to01,for+1and+2set16to03.

+1:EnableDFD™(DistantFaultDetection).FirmwareV1.40andlater,PCBV1.10andlater.

DFD™enables theZM1todetecta faultat theendof very long fences. Instead of only measuring thepeakcurrenttheZM1withDFD™calculatesthe“real”currentandrejectsthe“reactive”current.Thecurrentdisplayedwillusuallybelessthanreadbyastandardhand-heldmeterwiththisfeatureon.ThereisnotheoreticallimittothelengthoffencethattheZM1canmonitorwiththisfeatureon.WithoutDFD™thelimitisapproximately8km.

*DFD™isTradeMarkandPatentPendingbyEx-PTPtyLtd.

6.3.15 Anti-Bridging threshold (17x#)Anti-Bridging has been designed to detect a section of fence being bypassed, and removed,byanintruderbridgingtheadjacentfencesectionstogether. This also detects when the feed isconnectedtothereturnwithashortcable,andthentheentirefenceiscut.

Settingthisoptiontoavaluegreaterthan0(defaultis0=off)willenableAnti-Bridging.

WhileArmed,aFenceAlarmwilltriggeriftheFenceCurrentrisesORfallsquicklybymorethanthethreshold.AslowchangetotheCurrentwillnottriggeraFenceAlarmuntiltheCurrentismorethantheCurrentAlarmLevel(02x#)

TheAnti-BridgingThresholdisapercentagevalueoftheFenceCurrent.Forexample,settingoption17to50(1750#)willseta50%Anti-BridgingThreshold.AtthislevelaFenceCurrentnormallyreading10AmpswilltriggeraFenceAlarmiftheCurrentquicklyrisestoover15Aorfallstolessthan5A.

Measuringfencecurrenttodetermineifafenceisbridgedwillworkirrespectiveoftheenergizertypepoweringthefence.

Value Function0 None+1 EngageDFD*

Binary Options (16x#)

Value (x) thresholdMinimum0 DisabledMaximum90 90%

Anti-Bridging Threshold (17x#)

Page 32: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

30

Pro

gram

min

g O

ptio

ns

Value Function0 0 seconds

(immediate)1 30 Seconds2 1 Minute3 2 Minutes4 3 Minutes5 4 Minutes6 5 Minutes7 6 Minutes8 7 Minutes9 Disabled – Do

not auto re-armAuto Re-Arm Time (20x#)

6.3.16 Auto re-Arm time (20x#)The Auto Re-Arm Timeoption is identical to thatoftheZseriesofsecurityenergizers.

Thisoptionsets the timewhichmustelapsebeforeanother alarm will sound after the first alarm hastimedout(gonecompletelythroughitscycles).

Ifaneventoccurs(suchasalowfencevoltage)whichtriggers the siren, any other events which wouldotherwisetriggerthesiren(suchasagatealarm)willbeignoredwhilethesirenissoundinganduntilafterthe Auto Re-Arm time has passed.

Asettingof9willdisableautoRe-Arm.

IfthistimeissettolessthantheSiren Off Time,theunitmayre-arminthesirenofftimeandthenumberofsirencycleswillbereduced.

6.3.17 relay FunctionsAll relays can be set to any of theavailablefunctions(userassignable).

Relay1is(21x#)Relay2is(22x#),etc

Defaults for the ZM1:

• Relay1 – Siren• Relay2 – Strobe• Relay3 – Fence1• Relay4 – Armed• Relay5 – General

Note: The siren and strobe switched12V outputs can be used to driveexternalbufferrelays.

Value Function0 Fence 11 Fence1oroff2 Armed 13 GroundVoltage4 GroundVoltageorOff5 Not used6 Bi-Polar7 General8 Siren9 Strobe10 AC Fail11 Low/BadBattery12 Tamper13 Not used14 Gate Alarm15 Siren caused by Gate16 Not used

Relay Functions

Page 33: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

31

Program

ming O

ptions

6.3.18 Group Mode (26x#) At this time it is not possible to connect ZM1s into a group.

Since the ZM1 cannot control the pulse timing ofan attached energizer it cannot be grouped for thepurposesofsynchronising.NorcanitbeincludedinagroupwithotherZseriesenergizers.

It may be necessary to change 26 to 1 to enable PC controloftheZM1.

Value Function0 No Group1 Master2 Slave13 Slave24 Slave35 Slave46 Slave57 Slave68 Slave79 Slave8Group Mode (26x#)

Function Logic for alarm state (opposite of normal state)Fence alarm TheZM1isArmedANDthefencevoltagehasfallenbelowtheFence

AlarmVoltageLevel(Option01)formorepulsesthantheMissedPulse Count. Not latched.

Fence alarmoroff

TheZM1isDisarmedORtheZM1isArmedandfencevoltagehasfallenbelowtheFenceAlarmVoltageLevelformorepulsesthantheMissed Pulse Count. Not Latched.

Fence Bipolar Not applicable to the ZM1.

Armed The ZM1 is Armed.General ACfailORTamperORLowbatteryORinternalerror.Latchedfor

internal errors only.

Siren Fencealarm1ORfencealarm2ORGateOrTamper,willtimeoutafterthesirentimeouttime.Thisfunctionislatched.

Strobe Aspersirenbutdoesnottimeout,willremainonuntiltheZM1isDisarmed.Thisfunctionislatched.

AC Fail AlarmonACfail.

Battery Alarmonloworbadbattery.

Tamper Not applicable to the ZM1.

CUSTOMISED CODES

Customer Pin No. ...................

Installer Pin No: ......................

INSTALLER DETAILS

Name ........................................................

Phone No. ................................................

Date Of Installation .................................

Page 34: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

32

War

rant

y

All JVA products carry a 2-year warranty against defective components andworkmanship.Thewarranty excludes damage caused by acts ofNature such aslightning or flooding, power supply surges, rough handling, malicious actions orincorrectwiring.

Whilsteveryefforthasbeenmade tocheck that the informationcontained in thismanual isaccurate,JVATechnologiesPtyLtdwillnotbe liable to lossordamageresulting from construction, operation or failure of any installation or system.Installationofsecurityelectricfencesshouldbemadebytrainedprofessionalswithregardtotherelevantlocalstandardsandworkplacehealthandsafetyrequirements.

Product model purchased: .................................. Serial No.: ..........................

Customer Name: ..................................................................................................

Address: ..................................................................................................

..................................................................................................

..................................................................................................

Postal Code: .......................................

Tel. No.: Cell: ................................ Landline: ....................................

email: ..................................................................................................

Date purchased: ........................................

InvoiceNo.: ........................................

Dealer Name: ..................................................................................................

Dealer’s stamp

7. WARRANTY

Mail to your local JVA Dealer: rsA JVA service Department, P.o. Box 13898, Cascades 3202

republic of south Africa

Page 35: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

JVA ELECTRIC FENCE SYSTEMS

GSM MONITORS AND CONTROLS JVA ENERGIZERS

USING A CELL PHONEZ14 STANDARDAND BI-POLAR ENERGIZERS

Z-RANGE

WEB SERVER MONITORS AND CONTROLS

ENERGIZERS VIA THE INTERNET

Z14

Z18 STANDARDAND BI-POLAR ENERGIZERS

Customer SupportFor assistance: If you have any questions or need further assistance, please call your nearest JVA dealer. RSA Tel. No.: 0861 782 349.For service or repairs: If a service or repair is required, please package and label your energizer carefully and return it to your local JVA Service Centre.For warranty repairs: Include proof of purchase, e.g. invoice.Note: Repair centre details are displayed on the back cover of this manual.

Z18

Z28

Z28 STANDARD2-ZONE ENERGIZER

RANGE FEATURES INCLUDE

9.2 9.09.2 9.09.2 9.09.2 9.09.2 9.0

LCD voltage display Powerful 4 joules per zone peak output energy Designed to pass IEC60335.2.76 and EMC

standards (reports available on request) Wall mountable, robust enclosure with

detachable PCB chassis for ease ofinstallation and repair

Earth monitor input Gate input Key-switch Keypad programmable Lower-power mode Entry/Exit delay from gate input trigger Switched +12V outputs for Siren and

Strobe (up to 30 Watts for 3 minutes) Microprocessor controlled Outputs may be wired for BiPolar fences

(excluding Z28) Multiple single-zone energizers can be

wired as a group

PERIMETER PATROLCOMPLETE CONTROLSYSTEM MONITORING

EVENT LOGGING

Page 36: JVA ZM1 Manual Cover Zm1 Manual.pdf · reserves and border security. The ZM1 uses Patent Pending, DFD™ technology to determine if there is a fault on very long fences. The combination

East Rand (Jet Park)Aerostar Business Park219 Jet Park Road, Jet ParkTel: 011 397 3507

North Rand (Kya Sand)174 Bernie StreetRandburgTel: 011 708 6442

West Rand (Roodepoort)602 Ontdekkers RoadDelaréy, RoodepoortTel: 011 472 8823

Pretoria1185 Steve Biko Road(977 Voortrekker Road)Wonderboom SouthTel: 012 335 4290

Kimberley29 Schmidtsdrift RoadTel: 053 861 5631

JVA ELECTRIC FENCE SYSTEMS

Cape TownUnit 15, Viking Business ParkViking Way, Epping IndustriaTel: 021 534 5056

Polokwane19A Suez StreetNirvanaTel: 015 292 6273

NelspruitD1 Waterfall Park15 Rapid StreetRiverside Industrial ParkTel: 013 752 7152

Bloemfontein36 Kolbe LaneTel: 051 448 6695

PinetownUnit 1, 7 Suffert StreetTel: 031 702 6351

Rustenburg1 Howick Avenue, Shop 7, Waterfall MallTel: 014 537 2884

Durban NorthShop 11, Arcadia Centre87 Umhlanga Rocks DriveTel: 031 563 0274/ 031 563 6478

Pietermaritzburg51 Winston RoadTel: 033 342 6727

Port Elizabeth45 Mangold StreetNewton ParkTel: 041 365 7178

East LondonShop 3, Paphos ParkDevereaux AvenueTel: 043 726 6652/60

GeorgeShop 3, 57 York RoadGeorgeTel: 044 874 0669

Nearest RSA branch: 0861 782349 • Website: www.jvasecurity.com • e-mail: [email protected]

JVA SA SERVICE CENTRES

JVA products are designed by JVA Technologies,Queensland, Australia and distributed to:

AUSTRALIA AFRICA NEW ZEALAND

LATINO AMERICA CARIBBEAN SOUTH EAST ASIA

EUROPE RUSSIA INDIA

USA MEXICO

CENTRAL ASIA UNITED KINGDOM