32
JETFOIL AND LARGE AXIAL HIGH TEMPERATURE FANS » PART OF THE FIRE SAFETY PRODUCT PORTFOLIO AIR MOVEMENT FIRE SAFETY

JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

  • Upload
    vanthu

  • View
    248

  • Download
    4

Embed Size (px)

Citation preview

Page 1: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

Jetfo

il &

Larg

e Ax

ial C

atal

ogue

978

1GB

© C

opyr

ight

201

6 Fl

äkt W

oods

Lim

ited

JETFOIL AND LARGE AXIAL HIGH TEMPERATURE FANS

» PART OF THE FIRE SAFETY PRODUCT PORTFOLIO

AIR MOVEMENT

FIRE SAFETY

Page 2: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

2 OVERVIEW

LARGE - TUNNEL FANS

Fläkt Woods is the industry leader in air movement technology, providing innovative solutions worldwide. Our extensive knowledge of design and applications is based on over 100 years of experience in tunnels, buildings, industry and original equipment manufacturers. Fläkt Woods’ global coverage reaches over 100 countries and is supported by an extensive distribution network.

LARGE JM HIGH TEMPERATURE FANS • Size range 1.4 m to 2.8 m • Guaranteed performance to ISO 5801 • Unidirectional or Truly Reversible blade sections • Higher pressure twin impeller and 2 stage fans are available • High Temperature certification for 200°C and 300°C categories up to 710 kW, and 400 ºC up to 1000 kW • Static pressures up to 4000 Pa and volume flow up to 250 m3/s • Fans are tested up to 2.8 metre diameter, running at 1500 rpm, with a 1 MW motor • All cast rotating impeller components are examined by X-ray to ensure reliability in service • IEC motors certified to EN 12101-3 and ISO 21927-3 • Steel parts hot dip galvanised or hot Zinc Sprayed (except hub) • Manufacturer registered and assessed in accordance with BS EN ISO 9001 • Paint finish optional• Accessories: guards, condition monitoring, anti vibration mounts, flexible connectors, bellmouth/coned entries, diffusers, transition pieces, silencers, dampers, starters & controls

LARGE FAN INFORMATION PAGES 8 - 19

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 3: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

3OVERVIEW

JETFOIL - TUNNEL FANS

JETFOIL FANS• ø560 - ø1600 mm• Thrust up to 3500N• ø800 mm up to 1800 rpm, ø1250 mm up to 1800 rpm and ø1600 mm up to 1200 rpm • Fully adjustable die cast aluminium impellers in uni-directional and truly reversible configurations; and • 100% X-ray of all cast impeller components

• Mild steel casing - hot dipped galvanised after manufacture, painted or all stainless steel construction• Silencers fitted where required• Motor protection IP55 minimum• IEC motors certified to EN 12101-3• Emergency ventilation options up to 400 °C/2 hours • Truly reversible fans provide approximatey equal thrust and airflow in forward and reverse directions• Noise Levels: Fläkt Woods offer acoustic analysis and attenuators to ensure the fans are In accordance with environmental requirements and local regulations

• Applications; longitudinal ventilation of road tunnels, mine ventilation, emergency ventilation - smoke control, hangar/large area ventilation

Our expertise in tunnel ventilation applications covers road and rail tunnels, metros, tunnel construction and wind tunnels. Fläkt Woods’ products have been successfully used in underground projects throughout the world and our Jetfoil product range is unrivalled in its technology, innovation, efficiency and thrust.

JETFOIL FAN INFORMATION PAGES 20 - 29

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 4: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

4 VENTILATION

60º

COARSE MESH

ACOUSTICSPLITTERS

'I' SECTION BEAM FOR

FAN REMOVAL

NON-RETURNDAMPER ACOUSTIC

SPLITTERSCENTRAL

TUNNEL FAN

AIR IN

AIR OUT

VENTILATIONVentilation is required for safety and to maintain acceptable temperatures and comfort. Pollution emitted by trains and road vehicles must be removed to provide an acceptable and safe environment. The heat from a train may need to be removed by forced ventilation in order to ensure that the temperature is acceptable to both people and equipment. In the case of a fire, smoke must be removed in order to enable safe escape and to assist access to fight the fire.

The normal ventilation principles are to dilute pollution and to increase visibility by removal of particles.

In an emergency the smoke is controlled by creating sufficient air velocity to drive it away from the fire. Depending on the control strategy, the smoke can then be extracted. In rail and metro systems it is common to create a safe haven by pressurisation of the non-incident tunnel.

TUNNEL VENTILATION METHODSThere are a number of different types of ventilation methods for tunnels and these can either be used independently or in combination. Fläkt Woods can advise you in all aspects of tunnel ventilation.

FULLY TRANSVERSE SYSTEMA fully transverse system supplies fresh air from a low level, normally from a duct underneath the roadway. The hot, polluted air rises and is extracted at a high level normally through a ducted system above the roadway. This system gives the most precise level of control and generally uses large, fixed pitch, JM Aerofoil fans in parallel.

SEMI-TRANSVERSE SYSTEMThis system is similar to the fully transverse system for the supply and extraction of air and is used for long, congested two way tunnels. Semi-transverse systems rely on longitudinal air movement along the tunnel and require a higher ventilation rate.

LONGITUDINAL VENTILATION SYSTEMSThe simplest solution for tunnels as air movement is created along the length of the tunnel by large fans, jet fans or a combination of the two. The air can enter at one portal and leave at another, or be supplied or extracted at points within the tunnel.

THE SACCARDO NOZZLEThe Saccardo nozzle system operates on the principle that a high-velocity air jet is injected longitudinally into the tunnel to induce a high volume airflow in the tunnel. For this to be successful, the fans have to be carefully matched to optimise performance. The system uses blocks of JM Aerofoil axial fans, mounted in parallel for each tunnel which are fitted with special nozzles to accelerate the air.

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 5: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

5CERTIFICATION

EN 12101-3 AND ISO 21927-3 HT CERTIFICATIONEmergency, High Temperature, Smoke Extract Fans fall within the scope of the EU Construction Products Regulation.

The implementation of the Construction Products Regulation and the publication of the product specific standard, EN 12101-3 have made it a mandatory requirement for smoke control fans sold into the European Union to carry a CE Mark from April 1st, 2005.

The CE mark may only be affixed after successful completion of testing, auditing of factory production control and issue of a certificate by accredited independent authorities.

This procedure is intended to prevent fan failures during an emergency smoke situation, where a fan failure can ultimately lead to the loss of life.

Fläkt Woods fully endorse the concept that, in such a safety critical application, only fully verified and certified products should be specified. As such all JM fans are tested and certified.

The Fläkt Woods JM HT range was successfully tested and are certified to EN 12101-3 and ISO 21927-3 by a third party; however, because ISO 21927-3 applies globally, it provides specifications against which powered smoke and heat exhaust ventilators can be evaluated and certified outside EU member states.

Fläkt Woods worked with the certifying authorities to build and certify a high temperature facility capable of testing fans up to 3.5 metres diameter at up to 400°C.

This investment resulted in Fläkt Woods being able to offer a British Standards Institution Certified, CE marked JM HT product including 300°C/2 hours 400°C/2 hours ranges, in diameter starting at 1400mm up to a maximum of 2800mm at relevant time/temperature categories.

This investment also resulted in Fläkt Woods being able to offer a British Standards Institution Certified, CE marked Jet Fan product for use at 400°C/2 hours from 560mm to 1600mm, together with a comprehensive range of approved accessories.

Fläkt Woods have enhanced their position as the foremost provider of specialist products for emergency high temperature smoke control by becoming the first fan manufacturer in the world to be able to apply CE marking to these safety critical products, ensuring that Fläkt Woods has one of the most comprehensive range of products available in the World.

It is also believed that Fläkt Woods is now the only manufacturer to have successfully tested a 2.24 metre diameter fan, running at 1500 rpm, with a 1MW motor.

Fan label in accordance with CE marking directive EN12101-3

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 6: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

6 R&D FACILITIES

Our dedicated laboratory in Colchester, unique in the UK, is equipped to demonstrate and prove product performance and control strategies.

Other R&D facilities can be found in Scandinavia and North America. The fan performance is maintained and improved in line with a planned Research and Development programme to ensure optimised aerodynamic and acoustic performance.

Axial flow aerofoil fans aerodynamic performance is tested in accordance with ISO 5801 Type C code D; acoustic performance BS 848 in a semi reverberant area ISO 5136; Over speed 125% for 15 Minutes ; X-Ray examination ASTME 155; balance ISO 1940; vibration BS 848 pt7 ISO 14694.

Jet Fans Thrust ISO 13350; acoustic performance BS 848 in a semi reverberant area ISO 5136; over speed 125% for 15 minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694.

R&D FACILITIES

TESTLABORATORY CONTROL PANEL

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 7: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

7FAN SELECTOR

Overview

The Fan Selector is a software application that allows the user to select and configure from our wide range of Fläkt Woods Group products. The program is desktop based, installed locally onto the user’s computer but is designed to automatically check for updates using an internet connection, so information is always up to date.

Products available include, but not limited to are: Axial Fans (including Large Aerofoils and Jet Fans for Tunnel applications), Boxed Fans, Roof Extract Fans, Plate Mounted Fans and Centrifugal Fans.

How to aquire and obtain an account

The fan selector software can be downloaded and installed from http://fanselector.Fläktwoods.com

Our software is available also on request via CD / USB media which is the same as the one on the aforementioned link.

Once installed, you will be prompted to register your details to start using the software. On recieving your registration we will set up your account so that it delivers a customised set of product mix and price options (If applicable). We will then send you an e-mail confirming your user name and password to allow you to log on.

FAN SELECTOR

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Fan Selector – for quick and easy selection

Page 8: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

88 LARGE TUNNEL FANS

LARGE FAN SELECTION CURVES F300

10 100 500

10,000

1,000

100

500

5,000

Pa P

ress

ure

(Tot

al)

m³/s Volume Flow

10 100 500

10,000

1,000

100

500

5,000

Pa P

ress

ure

(Tot

al)

m³/s Volume Flow

Unidirectional 50Hz 4 & 6 Pole

Unidirectional 50Hz 8 & 10 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 9: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

99LARGE TUNNEL FANS

LARGE FAN SELECTION CURVES F300

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

Truly Reversible 50Hz 4 & 6 Pole

Truly Reversible 50Hz 8 & 10 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 10: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1010

LARGE FAN SELECTION CURVES F300

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

10 100 500

500

5,000

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Unidirectional 60Hz 4 & 6 Pole

Unidirectional 60Hz 8, 10 & 12 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 11: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1111

LARGE FAN SELECTION CURVES F300

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Truly Reversible 60Hz 4 & 6 Pole

Truly Reversible 60Hz 8 & 10 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 12: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1212

LARGE FAN SELECTION CURVES F400

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

140JMFG64

160JMFG64

200JMFG9018JMFG72

224JMFG112

160JM

FG64

180JM

FG72

200JMFG

80 224JM

FG80

250JMFG

140

280JMFG

140

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Unidirectional 50Hz 4 & 6 Pole

Unidirectional 60Hz 8, 10 & 12 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 13: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1313

LARGE FAN SELECTION CURVES F400

224JMFTS112

200JMFTS90180JMFTS72

160JMFTS62

140JMFTS62

280J

MFTS

140

250J

MFTS1

00

224JM

FTS8

0

200JMFT

S80

180JMFT

S72

160J

MFTS6

2

6 Pole

4 Pole

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

280JMFTS140

250JMFTS100

224JMFTS

80

280J

MFTS1

40

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Truly Reversible 50Hz 4 & 6 Pole

Truly Reversible 50Hz 8 & 10 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 14: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1414

LARGE FAN SELECTION CURVES F400

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Unidirectional 60Hz 4 & 6 Pole

Unidirectional 60Hz 8, 10 & 12 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 15: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

1515

LARGE FAN SELECTION CURVES F400

140JMTS64

250J

MTS14

0

224JM

TS112

200JMTS

90

180J

MTS72

160JMTS

64

140J

MTS64

6 Pole

4 Pole

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

280JMTS140

250JMTS100224JMTS80

200JMTS80

180JMTS72 224JMTS80

250JMTS100

280JMTS140

280J

MTS14

0

m³/s Volume Flow

Pa P

ress

ure

(Tot

al)

LARGE TUNNEL FANS

Truly Reversible 60Hz 4 & 6 Pole

Truly Reversible 60Hz 8, 10 & 12 Pole

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 16: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

16

LARGE FAN DIMENSIONS AND WEIGHTS - VERTICAL MOUNTING

The motor is sized for the highest absorbed power of the curve. An indication of the motor rating may be established by the calculation shown below:

Unidirectional fans: Motor power (kW) = Flow (m3/s)*total pressure (Pa)*0.0015 Truly reversible fans: Motor power (kW) = Flow (m3/s)*total pressure (Pa)*0.0017

Motor Power (kW)

50 Hz 55 75 90 110 132 160 200 250 315 355 400 450 500 560

60 Hz 63 86 103 126 152 184 230 287 362 408 460 517 575 644

4 poles 446 720 756 900 1007 1000 1525 1651 1835 1865 2140 2140 2500 3200

6 poles 645 830 930 1000 1150 1520 1754 1916 2180 2500 2900 3150 3300 3400

8 poles 830 930 1021 1390 1520 1680 1820 2180 2600 3200 3400

F300 & F400 Motors Weight (kg)

Note: For motors exceeding the kW catalogue refer to Fläkt Woods - Colchester.

Fan Dia A B C

MAXD

MAXL

CRS M H PCD S T

Max Fan Weight

Less Motor (kg)

1400 1400 1560 2050 1050 1750 2000 1470 20 15 2000

1600 1600 1760 2050 1150 1950 2200 1680 24 18 2365

1800 1800 1960 2050 1250 2250 2400 1880 24 18 2425

2000 2000 2160 2050 1350 2500 2650 2080 24 18 2500

2240 2240 2415 2050 1470 2840 3000 2320 24 18 2720

2500 2500 2716 2650 1700 3100 3250 2580 24 18 4620

2800 2800 3055 2650 1850 3400 3650 2880 24 18 5220

LARGE TUNNEL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 17: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

17

LARGE FAN DIMENSIONS AND WEIGHTS - HORIZONTAL MOUNTING

The motor is sized for the highest absorbed power of the curve. An indication of the motor rating may be established by the calculation shown below:

Unidirectional fans: Motor power (kW) = Flow (m3/s)*total pressure (Pa)*0.0015 Truly reversible fans: Motor power (kW) = Flow (m3/s)*total pressure (Pa)*0.0017

Motor Power (kW)

50 Hz 55 75 90 110 132 160 200 250 315 355 400 450 500 560

60 Hz 63 86 103 126 152 184 230 287 362 408 460 517 575 644

4 poles 446 720 756 900 1007 1000 1525 1651 1835 1865 2140 2140 2500 3200

6 poles 645 830 930 1000 1150 1520 1754 1916 2180 2500 2900 3150 3300 3400

8 poles 830 930 1021 1390 1520 1680 1820 2180 2600 3200 3400

Fan Dia A B C

MAXD

MAX F K CRS

L CRS M P H

PCD S T

Max Fan Weight

Less Motor (kg)

1400 1400 1538 2050 1050 1670 1700 1300 1400 900 1470 20 15 1400

1600 1600 1760 2050 1150 1962 1700 1454 1600 1082 1680 24 18 1765

1800 1800 1960 2050 1250 2162 1700 1500 1800 1182 1880 24 18 1785

2000 2000 2160 2050 1350 2418 1700 1630 2000 1330 2080 24 18 1850

2240 2240 2415 2050 1470 2658 1700 1830 2200 1450 2320 24 18 2000

2500 2500 2716 2650 1700 2968 2500 1940 2000 1610 2580 24 18 3700

2800 2800 3055 2650 1850 3288 2500 2190 2250 1760 2880 24 18 4170

F300 & F400 Motors Weight (kg)

Note: For motors exceeding the kW catalogue refer to Fläkt Woods - Colchester.

LARGE TUNNEL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 18: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

ATMOSPHERE SILENCER

FAN

SQUARE TO ROUND TRANSFORMATION SECTION

SPRING VIBRATION SIOLATORS

FLEXIBLE CONNECTOR(S)

SYSTEM SIDE SILENCER

AIRFLOW

18

LARGE FAN ACCESSORIES AND ADDITIONAL FEATURES

SilencersFläkt Woods has over 50 years experience in noise control engineering and can assess and design silencers to meet sound attenuation on both system and atmospheric sides. Attenuators can be provided as complete units, modules and splitter only to suit on site conditions. Airways velocity above 10m/s should be avoided to limit system pressure and noise generation.

Product AccessoriesSuch as inlet cones, guards, flexible connectors and anti-vibration mountings are available. For further information, please enquire.

Typical Installation - Horizontal Airflow

INLET CONE FLEXIBLE SLEEVES & MATCHING FLANGES

GUIDE VANES

INLET WIRE GUARD ANTI VIBRATION MOUNTINGS

DIFFUSERS

LARGE TUNNEL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 19: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

19

LARGE FAN ACCESSORIES AND ADDITIONAL FEATURES

DampersKey to the control and operation of many ventilation systems are control dampers. These should normally be sized on an airway velocity of 8m/s or below in order to avoid excessive system pressure and excess sound generation. Physical support must be designed in to accept both static and dynamic loading.

Vibration/Condition MonitoringPrinciple operating monitoring systems are available on the fans to minimise risks of breakdown and enable programmed maintenance to be effectively planned. Optionsinclude bearing vibration and temperature systems, bearing condition monitoring and motor winding condition. We will be pleased to discuss the best choice for your application.

Motor Starters/ Inverter DrivesDrive systems can be supplied and specified through Fläkt Woods to match the operating characteristics of the fan drives and ensure compatibility of the complete package. Interfacing with key control and management systems are principle specification requirements.

After Sales ServiceFläkt Woods Service and Repair Division offer a full range of site support activity that includes routine monitoring site surveys and service contracts. Please contact Fläkt Woods for further details.

LARGE TUNNEL FANS

AIRFLOW

ATMOSPHERE SILENCER

SUPPORT STEEL WORKFOR ATMOSPHERE SIDESILENCERAND ATMOSPHERESIDE TRANSFORMATIONSECTION

SQUARE TO ROUND TRANSFORMATION SECTION

FAN

SUPPORT STEEL WORK FOR FAN SYSTEM SIDE TRANSFORMATION SECTION

SQUARE TO ROUND TRANSFORMATION SECTION

SYSTEM SIDE SILENCER

FLEXIBLE CONNECTOR

SPRING VIBRATION SIOLATORS

FLEXIBLE CONNECTOR

Typical Installation - Vertical Airflow

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 20: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

20 OVERVIEW

STANDARD RANGERange includes:• 10 diameters - 560 mm to 1600 mm • Swept back arm design for improved performance and noise reduction • Zinc galvanised or stainless steel casing • IP55 motor protection minimum • Low installed noise levels • High energy efficiency • ISO standard 13350

Options:• Silencers with or without acoustic pod fitted • Mounting frame to ensure secure installation • Epoxy paint

HIGH TEMPERATURE RANGERange includes: • 10 diameters - 560 to 1600 mm • 200/2, 300/2 or 400/2 operation • 50 Hz or 60 Hz supply • HT Approved and certified fans motors • Additional impeller locking feature for extra security

Options:• Epoxy paint on top of galvanised finish for enhanced protection • Bolt-on Silencers • Accessories

JETFOIL RANGE

20 JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 21: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

21OVERVIEW

FAN CODES 112 JMTS / 40 / 4 / 9 / 32FAN DIAMETER56 = 560MM 100 = 1000MM63 = 630MM 112 = 1120MM71 = 710MM 125 = 1250MM80 = 800MM 140 = 1400MM90 = 900MM 160 = 1600MM

FAN DIAMETERJMTS = TRULY SYMMETRICAL JET FANJMG = UNI-DIRECTIONAL JET FAN

HUB DIAMETER20 = 200MM 40 = 400MM25 = 250MM 50 = 500MM31 = 315MM 63 = 630MM

MOTOR POLE2 = 2 POLE4 = 4 POLE6 = 6 POLE8 - 8 POLE

NO. OF BLADES5 = 5 BLADES6 = 6 BLADES9 = 9 BLADES12 = 12 BLADES

BLADE PITCH ANGLE IN DEGREES

21JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 22: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

22 OVERVIEW

0

1000

2000

3000

4000

632 714 712 804 904 1006 1004 1126 1124 1256 1254 1406 1404 1608 1606

Thru

st (N

)

300/2 Unidirectional 50Hz

0

500

1000

1500

2000

2500

3000

3500

4000

714 804 904 1006 1004 1126 1124 1256 1406 1608 1606

Thru

st (N

)

300/2 Unidirectional 60Hz

0

500

1000

1500

2000

2500

3000

562 632 714 712 804 802 904 1006 1004 1126 1124 1256 1254 1408 1406 1608 1606

Thru

st (N

)

300/2 Reversible 50Hz

0

500

1000

1500

2000

2500

3000

3500

4000

714 804 904 1006 1126 1256 1408 1406 1608 1606

Thru

st (N

)

300/2 Reversible 60Hz

0

1000

2000

3000

4000

632 714 712 804 904 1006 1004 1126 1124 1256 1254 1406 1404 1608 1606

Thru

st (N

)

300/2 Unidirectional 50Hz

0

500

1000

1500

2000

2500

3000

3500

4000

714 804 904 1006 1004 1126 1124 1256 1406 1608 1606

Thru

st (N

)

300/2 Unidirectional 60Hz

0

500

1000

1500

2000

2500

3000

562 632 714 712 804 802 904 1006 1004 1126 1124 1256 1254 1408 1406 1608 1606

Thru

st (N

)

300/2 Reversible 50Hz

0

500

1000

1500

2000

2500

3000

3500

4000

714 804 904 1006 1126 1256 1408 1406 1608 1606

Thru

st (N

)

300/2 Reversible 60Hz

PERFORMANCE RANGE WITH 1D SILENCERS300/2 RANGE

Higher thrust levels available, please enquire for further information

22 JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 23: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

23OVERVIEW

0

500

1000

1500

2000

2500

3000

71 4 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 6 160 8 160 6

Thru

st (N

)

400/2 Unidirectional 50Hz

0

500

1000

1500

2000

2500

3000

71 4 80 4 90 4 100 6 112 6 125 6 140 6 160 8 160 6

Thru

st (N

)

400/2 Unidirectional 60Hz

0

500

1000

1500

2000

2500

3000

56 2 63 2 71 4 71 2 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 8 140 6 160 8 160 6

Thru

st (N

)

400/2 Reversible 50Hz

0

500

1000

1500

2000

2500

71 4 80 4 100 6 112 6 125 6 140 8 160 8

Thru

st (N

)

400/2 Reversible 60Hz

0

500

1000

1500

2000

2500

3000

71 4 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 6 160 8 160 6

Thru

st (N

)

400/2 Unidirectional 50Hz

0

500

1000

1500

2000

2500

3000

71 4 80 4 90 4 100 6 112 6 125 6 140 6 160 8 160 6

Thru

st (N

)

400/2 Unidirectional 60Hz

0

500

1000

1500

2000

2500

3000

56 2 63 2 71 4 71 2 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 8 140 6 160 8 160 6

Thru

st (N

)

400/2 Reversible 50Hz

0

500

1000

1500

2000

2500

71 4 80 4 100 6 112 6 125 6 140 8 160 8

Thru

st (N

)

400/2 Reversible 60Hz

Higher thrust levels available, please enquire for further information

PERFORMANCE RANGE WITH 1D SILENCERS400/2 RANGE

23JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 24: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

24 JETFOIL FANS

Fan type

Motor Pole

Speed

Blade Angle

Thrust N

Outlet Velocity

m/s

Absorbed Power

kW

Motor Power kW

Nominal Current

A

Sound power LwA

Sound Pressure

in free field, 45º, 10m

dB(A)

Weight(Kg)

63JMG

2 20 324 29.4 9.2 11.04 20.2 104 73 194

2 24 419 33.5 12.6 12.65 23.3 106 75 194

2 29 529 37.6 17.6 18 32.6 97 66 310

2 32 592 39.8 21.1 22.2 40.4 98 67 310

2 36 672 42.4 26.1 27 49.8 99 68 310

71JMG

2 22 575 34.8 17.8 18 32.6 100 69 326

2 25 672 37.6 21.6 22.2 40.4 101 70 326

2 28 772 40.3 26.5 27 49.8 101 70 326

2 34 943 44.6 38.9 40 74.6 103 72 379

80JMG

4 27 289 21.9 4.62 4.8 9.2 87 56 216

4 32 355 24.3 6.4 6.6 12.6 89 58 282

4 36 408 26 8.2 8.63 16.3 91 60 282

4 40 457 27.5 9.8 11.04 21 93 62 282

100JMG

4 26 661 26.5 12.7 13.2 25.4 97 66 282

4 31 819 29.5 17.7 18 35 99 68 493

4 38 1038 33.2 26.4 27 49.8 101 70 493

4 40 1088 34 28.7 33 65 102 71 540

112JMG

4 21 878 27.2 16.7 17.3 33.1 92 61 581

4 27 1176 31.5 26.8 27 49.8 95 64 581

4 31 1378 34.1 34.8 36 67 96 65 727

4 34 1532 36 41.6 42.55 77.7 98 67 727

4 37 1687 37.8 49 49.5 94.8 99 68 727

4 40 1826 39.3 56.9 63.3 110 100 69 845

125JMG

4 20 1289 29.6 33.9 34.5 63.8 99 68 827

4 24 1665 33.6 46.7 49.5 94.8 100 69 827

4 28 2021 37 61.2 63.3 110 101 70 968

4 33 2438 40.7 82.4 86.3 154 103 72 1074

140JMG

6 26 1141 24.9 21.8 22.2 42.7 95 64 976

6 33 1500 28.5 34.5 36 66.2 98 67 1107

6 37 1710 30.4 42.8 44.4 79.9 100 69 1224

6 40 1868 31.8 49.8 51.8 92.3 101 70 1224

160JMG6 20 1253 22.8 24.7 26.4 49.7 98 67 1202

6 25 1606 25.8 34.6 36 66.2 99 68 1345

6 31 2087 29.4 51.6 51.8 92.3 101 70 1453

50Hz UNIDIRECTIONAL RANGE 300/2H

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 25: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

25JETFOIL FANS

Fan type

Motor Pole

Speed

Blade Angle

Thrust N

Outlet Velocity

m/s

Absorbed Power

kW

Motor Power kW

Nominal Current

A

Sound power LwA

Sound Pressure in forward direction

in free field, 45º, 10m

dB(A)

Weight(Kg)

56JMTS

2 22 133 21.2 3.3 3.6 6.93 94 63 150

2 30 211 26.7 6.4 6.6 12.3 95 64 180

2 35 260 29.7 8.8 9 16.4 97 66 180

2 40 304 32.1 12.2 12.65 23.3 101 70 180

63JMTS

2 20 177 21.8 4.4 4.6 9.3 93 62 168

2 24 229 24.8 6.5 6.6 12.3 95 64 197

2 28 290 27.8 8.8 9 16.4 96 65 197

2 32 354 30.8 11.9 12.65 23.3 98 67 197

2 37 425 33.7 17.2 18 32.6 99 68 314

2 40 466 35.3 20.7 22.2 40.4 100 69 314

71JMTS

2 20 320 25.9 8.1 8.25 15.5 100 69 183

2 24 415 29.5 12.1 12.65 23.3 100 69 244

2 28 516 32.9 17.4 18 32.6 101 70 331

2 33 660 37.3 26.3 27 49.8 103 72 331

2 35 698 38.3 30.9 33 58.8 104 73 385

80JMTS

4 30 259 20.7 4.6 4.8 9.2 90 59 220

4 35 324 23.2 6.6 6.6 12.6 92 61 286

4 40 374 24.9 8.9 9 17 94 63 286

4 44 395 25.6 10.8 11.04 21 95 64 286

90JMTS4 35 534 26.4 12.4 13.2 25.4 90 59 441

4 40 617 28.4 17 17.3 33.1 92 61 441

4 43 648 29.1 19.6 20.35 39.5 93 62 441

100JMTS

4 29 566 24.5 12.1 13.2 25.4 100 69 500

4 34 704 27.3 17.1 17.3 33.1 101 70 500

4 39 896 30.8 26.1 27 49.8 104 73 546

4 44 1011 32.8 31.1 33 65 106 75 546

112JMTS

4 30 1023 29.4 25.4 27 49.8 97 66 589

4 33 1180 31.6 32 33 65 98 67 648

4 37 1356 33.9 42.6 44.4 79.3 100 69 856

4 41 1495 35.6 53.7 54 95.1 102 71 856

4 44 1551 36.2 61.2 63.3 110 103 72 856

125JMTS

4 25 1074 27 26.4 27 49.8 101 70 685

4 28 1300 29.7 33.9 34.5 63.8 102 71 841

4 31 1546 32.4 43.9 44.4 79.3 104 73 982

4 33 1715 34.1 52.1 54 95.1 104 73 982

4 36 1960 36.5 65.7 66 115 105 74 1095

4 40 2251 39.1 83.6 86.3 154 107 76 1095

140JMTS

6 32 1186 25.3 25.7 26.4 49.7 99 68 991

6 36 1393 27.5 34.4 36 66.2 100 69 112

6 40 1555 29 44.1 44.4 79.9 102 71 1245

6 43 1631 29.7 50.9 51.8 92.3 103 72 1245

160JMTS

6 23 1234 22.6 25.3 26.4 49.7 100 69 1217

6 27 1571 25.5 34.7 36 66.2 101 70 1360

6 30 1856 27.7 43.3 44.4 79.9 101 70 1474

6 40 2555 32.5 84.5 86.3 155 105 74 1600

50Hz TRULY REVERSIBLE RANGE 300/2H

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 26: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

26

Fan type

Motor Pole

Speed

Blade Angle

Thrust N

Outlet Velocity

m/s

Absorbed Power

kW

Motor Power kW

Nominal Current

A

Sound power LwA

Sound Pressure in free field, 45º , 10m

dB(A)

Weight(Kg)

71JMG

4 23 222 21.6 4.1 4.32 7.61 98 67 171

4 30 307 25.4 6.6 6.93 12.9 99 68 180

4 35 368 27.8 9 9.78 16.3 101 70 241

4 40 427 30 11.5 12.1 20.2 105 74 241

80JMG

4 25 378 25 6.8 6.93 12.9 91 60 216

4 30 472 28 9.6 9.78 16.3 93 62 282

4 35 568 30.7 13.1 13.8 22.3 95 64 282

4 40 640 32.6 16.7 19.6 32.8 97 66 370

90JMG4 25 526 26.3 13.3 13.8 22.3 89 58 330

4 29 644 29 18.1 19.6 32.8 91 60 436

4 34 806 32.5 25.9 28.8 46.9 93 62 525

100JMG

4 20 744 28.1 18 19.6 32.8 101 70 493

4 25 1012 32.8 26.7 28.8 46.9 102 71 540

4 31 1312 37.3 39.1 39.6 66.3 104 73 540

4 37 1586 41 53.9 58.3 96.7 106 75 614

112JMG

4 20 1237 32.3 27.4 28.8 46.9 96 65 639

4 25 1606 36.9 41.7 43.2 68.8 98 67 727

4 31 2039 41.5 62.6 63.6 97 101 70 845

4 34 2207 43.2 74.8 75.6 115 102 71 1070

4 39 2580 46.7 97.5 97.8 150 104 73 1070

125JMG6 26 974 25.7 19.4 20.4 32 95 64 737

6 32 1256 29.2 28.9 30 50 98 67 827

6 39 1565 32.6 42.2 43.2 68.1 100 69 968

140JMG

6 20 1266 26.2 24.3 25.2 41.6 97 66 976

6 27 1796 31.2 42.7 43.2 68.1 100 69 1107

6 29 1950 32.5 48.8 50.4 79.3 101 70 1224

6 32 2184 34.4 58.9 61 94.9 102 71 1224

160JMG6 21 1967 28.6 47.5 50.4 79.3 103 72 1453

6 24 2284 30.8 58 61 94.9 104 73 1453

60Hz UNDIRECTIONAL RANGE 250/2H

JETFOIL ACCESSORIESJET FAN SILENCER GUARDS MOUNTING FEET

JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 27: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

27

60Hz TRULY REVERSIBLE RANGE 250/2H

JETFOIL ACCESSORIESACOUSTIC POD BELLMOUTH INLET SPRING VIBRATION ISOLATORS

Fan type

Motor Pole

Speed

Blade Angle

Thrust N

Outlet Ve-locity m/s

Absorbed Power

kW

Motor Power kW

Nominal Current

A

Sound power LwA

Sound Pressure in free field, 45º , 10m

dB(A)

Weight(Kg)

71JMG4 30 207 20.9 4.3 4.32 7.61 90 59 174

4 33 239 22.4 5.5 5.76 9.75 91 60 183

4 36 271 23.9 6.9 7.56 12.7 93 62 244

80JMG

4 25 285 21.7 5.6 5.76 9.75 93 62 220

4 32 419 26.4 9.4 9.78 16.3 94 63 286

4 37 508 29 13.1 13.8 22.3 97 66 286

4 44 564 30.6 19 19.6 32.8 99 68 380

90JMG

4 27 489 25.3 11.8 12.1 20.2 91 60 337

4 30 578 27.5 14.9 15 25.6 92 61 441

4 33 667 29.6 18.9 19.6 32.8 94 63 441

4 39 818 32.7 28.4 28.8 46.9 96 65 530

4 44 885 34.1 36 39.6 66.3 98 67 530

112JMG

6 28 1241 32.4 40.2 41.4 65.6 107 76 739

6 31 1438 34.9 49.4 50.4 77.9 108 77 856

6 35 1693 37.8 63.2 63.6 97 109 78 856

6 37 1813 39.2 71.7 72.5 110 110 79 856

6 40 1980 40.9 87.8 97.8 150 112 81 1080

125JMG

6 28 936 25.2 19.4 20.4 32 97 66 748

6 31 1083 27.1 24.2 25.2 41.6 98 67 841

6 34 1227 28.9 29.6 30 50 100 69 841

6 40 1466 31.6 41.8 43.2 68.1 102 71 982

6 44 1544 32.4 50 50.4 79.3 103 72 1095

140JMG6 26 1293 26.5 29.2 30 50 101 70 991

6 30 1627 29.7 40.2 43.2 68.1 102 71 1122

6 35 2034 33.2 58.8 61 94.9 104 73 1245

160JMG6 22 1736 26.8 41.5 43.2 68.1 104 73 1360

6 24 1957 28.5 49.4 50.4 79.3 105 74 1474

6 26 2209 30.3 57.8 61 94.9 105 74 1474

JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 28: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

28

Max

3.3

D

D

1.2 D

OPT

ION

AL

AN

CILL

ARY

Max

5.2

D

1.2 D

D

OPT

ION

AL

AN

CILL

ARY

JETFOIL OUTLINE DRAWINGS

JET FAN WITH 1D SILENCERS JET FAN WITH 2D SILENCERS

JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 29: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

29

JETFOIL OUTLINE DRAWINGSIt is recommended that a Fläkt Woods frame accompany the jet fan to ensure a secure installation. Anti-vibration mounts are available for soft mounting installations.

BASE FAN NO SILENCERS

JETFOIL FANS

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 30: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

30 REFERENCES

SAMPLE PROJECT REFERENCE LIST - RAIL / METRO

Country ProjectAustralia Parramatta Rail LinkAustria U3 Station ErdbergAustria U2/1 SchottenringAustria River CityAustria U1 UnterwerkAustria U2 MesseAustria U4 SchottenringAustria Vienna Metro - GrossAustria Vienna Metro - LeoupAustria Obb wien mitteAustria U4 schotatenringBrazil Sao Paulo Metro Line 4Canada TTC ShepherdCanada TTC PetrofitCanada TTC York Mills Canada Montreal STCUMChina Guangzhou MetroDenmark Copenhagen MetroDubai Dubai Light RailwayGreece Attiko Metro - Elliniko Ext.Greece Egnatio Odos Driscos TunnelGreece Attiko Metro, AthensHong Kong TKO South Hong KongHong Kong Beacon Hill TunnelHong Kong Lok Ma ChauHong Kong Penny’s Bay LineHong kong Mtr/tsy stationHungary Budapest Metro Line 2Hungary Budapest Metro Line 4India Delhi Metro Phase IIIndia Delhi MetroIndia DMRC Phase 1 (Mc1b)India DamelIndia Dwarka sector 21 east Iran Mashhad MetroItaly Passante Ferroviario Di TorinoItaly Torino Di BolognaItaly Nodo Di BolognaItaly Passante FerroviarioItaly Turin MetroItaly Turin Metro Lot 6c ProjectItaly Rome Rail StationItaly AviglianaItaly Alifana MetroItaly Milan MetroItaly Metro Station NapoliItaly Milan Metro Line 3 extensionItaly Monterrobbio Milan metro 2Italy Nci Roma Italy Turin metro New Zealand Britomart ProjectNew Zealand Otira Rail TunnelPortugal Lisbon MetroPortugal Porto MetroPuerto Rico Tren Urbano Romania Bucharest MetroSingapore CCL2Singapore CCL3Singapore CCL4

Country Project Singapore CCL5Singapore KPE ExpresswaySingapore North East LineTaiwan Nankang Extension ProjectTaiwan KMRTTurkey Adana Light RailTurkey Antalya Light Rail Turkey Marmaray Rail TunnelUK Bank Station DLRUK Channel Tunnel Rail LinkUK Cooling the TubeUK Docklands Light RailwayUK Jubilee Line ExtensionUK Liverpool Street StationUK Heathrow T5 Track TransitUK Woolwich Arsenal ExtensionUSA Las Vegas Airport USA MBTA Greenline (Boston) USA NYCTA E-31261 USA NYCTA E-31080 USA NYCTA E-31255 USA NYCTA E_31269 USA NYCTA E-31264 USA Amtrak Penn Station USA NYCTA C-20201 USA NYCTA C-20203 USA NYCTA E-31265 USA NYCTA E-31243 USA Trimet (Portland, OR) USA MARTA (Atlanta) USA NJNY PATH USA BART (San Francisco) USA MBTA R-10 (Boston) USA MSP Light Rail USA NYCTA C-52003 USA NYCTA E-31271 USA Amtrak Weehauken USA NYCTA E-31277 USA SEA-TAC USA NYCTA 03A8607 USA Cincinnati Airport USA Denver Airport USA NYCTA E-31287 USA NJT NERL USA Amtrak 1st Ave USA Beacon Hill (Seattle) USA NYCTA E-31274 USA NYCTA E-31278 USA Maverick (Boston) USA NYCTA A-36006 USA NYCTA E-31290R USA Pittsburgh North Connector USA Transportation Hub USA NJT Bergen USA SDSU LRT USA Beacon Hill (Seattle) USA Pittsburgh North Connector USA LA Mid-ConnectorVenezuela Valencia Metro

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 31: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

31REFERENCES

SAMPLE PROJECT REFERENCE LIST - ROAD

Country ProjectAlgeria Algerian Road TunnelAustralia Mitcham Frankston FreewayAustralia M5 East TunnelAustralia Lane CoveAustralia Brisbane eastern busway Austria Wske TunnelBelgium Gare De NamurBelgium Leopold IIBrazil Lamsa tunnelCanada Toronto AirportChina Hu Rong Su Tunnel China Chong Qin Fang Dou ShanChina Sky Pier (Tunnel 1)China Hu Nan Jia Hou YanChina Hu Nan Xue Feng Shan TunnelCroatia Tunnel TrsatCroatia Tunnel SkurinjeCroatia Sveti Rok 2Croatia Mala KapelaCroatia Veliki GlozacCroatia Tunnel BiskoCroatia Tunnel MravinceCroatia Tunnel StrazinaCroatia CardakCroatia BrezovicaCroatia Sveta Tri KrajlaCroatia Mala KapelaCroatia Tunnel pecineDubai Dubai International AirportFinland Kehu ProjectFinland Hakamaentie/Kivihaka TunnelFinland Vuoli TunnelFinland Keha 1Finland Kehu 2France Tunnel du Vieux PortFrance A14France A86France A51Greece Egnatia Odos-Panagia-GrevenaGreece EftaxiasHong Kong Route 8Hong Kong Sky PlazaHong Kong Lantau Airport & RailwayHong kong Contract 708India DAMELIndia C DoctorItaly Seiano TunnelItaly Montenegrone ProjectItaly MartignanoItaly Gran SassoItaly Mongrando TunnelItaly Gra Salva CandidaItaly Cesena TunnelItaly Valsassina TunnelItaly SpeziaItaly Lonato TunnelItaly Ronco TunnelItaly Val Badia Tunnel

Country Project Italy Marinasco TunnelItaly Autostrada del FioriLuxembourg Tunnel HowaldMalaysia SMARTMonaco T33 TunnelMonaco TFT TunnelNew Zealand JHT New ZealandNorway E18 - Bjorvika TunnelnNorway Norway Road TunnelNorway Mesta AsNorway KrakeroytunnelenNorway Sporsmal om malNorway TussentunnelnPoland Rondo TunnelPortugal Tunnel Do Rossio Portugal Moscavide aeroportoPuerto Rico Tven UrbanaQatar New Doha International AirportQatar NDIA Free Trade ZoneSaudi Arabia Jamarat Bridge Phase IISaudi Arabia Jamarat Bridge BasementSaudi Arabia King Khalid Road TunnelSaudi Arabia King Abdullah TunnelSerbia Vrmac TunnelSingapore Singapore Metro LinkSweden Arlandabanan, StockholmSwitzerland Biasca TunnelSyria Kafar Sousah Road TunnelTaiwan PinglinUK A3 Hindhead TunnelUK Bell Common TunnelUK Holmesdale TunnelUK Limehouse LinkUK Terminal 5 - Coach StationUK T5 - Taxi BridgeUK Blackwall TunnelUK New Tyne CrossingUSA Bunyard Tunnel USA Detroit Airport USA Minneapolis Airport USA Tulip City Airport USA Whittier TunnelYemen Sayhut-Nishtun Road Project

Fläkt Woods 9781GB 2016.07 Specifications are subject to alteration without notice

Page 32: JETFOIL AND LARGE AXIAL - pdfs.findtheneedle.co.ukpdfs.findtheneedle.co.uk/40930.pdf · minutes; X-Ray examination ASTME 15; balance ISO 1940; vibration BS848 pt7 ISO 14694. R&D FACILITIES

WWW.FLÄKTWOODS.COM ETCE FIRE DAMPER | 0000GB | 20140101

Jetfo

il &

Larg

e Ax

ial C

atal

ogue

978

1GB

© C

opyr

ight

201

6 Fl

äkt W

oods

Lim

ited

» To learn more about our offering and get in contact with your nearest sales representative please visit www.Fläktwoods.com

AIR MOVEMENT - FANS CENTRE OF EXCELLENCEAxial Way, Colchester, Essex. CO4 5ZD Tel: +44 (0)1206 222555

WE BRING BETTER AIR™ TO LIFEWith over a century of innovation and expertise to share with our customers, Fläkt Woods is a global leader in Air Technology products and solutions. We specialize in the design and manufacturing of a wide range of products and solutions for Air Movement, Air Treatment, Air Distribution, Air Management and Air Diffusion with focus on two major benefits – Air Comfort and Fire Safety. With market presence in 65 countries we are in a unique position to be a local supplier and an international partner in our customer’s projects.

Our product brands such as SEMCO®, eQ®, eQ Prime®, JM Aerofoil®, JMv Aerofoil®, VCC technology®, Econet®, Veloduct®, Optivent®, Optimix®, Econovent® and Cleanvent® are well-known and trusted by customers all over the world to deliver high quality and energy efficient solutions.

WWW.FLAKTWOODS.COM TUNNELS/JETFOIL | 9781GB | 07.2016