1-IuB Data Configuration Overview
2-IuB NodeB configuration process using CME
3-IuB RNC configuration process
8/12/2019 IuB Data Configuration
3/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3
AbbreviationsCME Configuration Management Element
WBBPa WCDMA Baseband Process unit Type A
WRFU WCDMA Radio Filter Unit
UBFA Universal BBU Fan Unit Type A
UEIU Universal Environment Interface unit
UELP Universal E1/T1 Lighting Protection unit
UFLP Universal FE/GE Lighting Protection unitUPEU Universal Power and Environment Interface Unit
UTRP Universal Transmission Processing Unit
DCDU-01 Direct Current Distribution Unit-01
EXT Extending
MRRU Multi-carrier Remote radio unit
CPRI Common Protocol Radio Interface
NPSU NodeB Power Supply Unit
NPMU NodeB Power Monitoring Unit
8/12/2019 IuB Data Configuration
4/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4
1- IuB Data Configuration Overview
NodeB initial data configuration
Definition:
NodeB initial configuration is the process of preparing and configuring the data
after the NodeB hardware components are installed. The configuration is based
on the NodeB hardware components, network planning, and data negotiationbetween the NodeB and other equipment. After the configuration, a data
configuration file is generated.
8/12/2019 IuB Data Configuration
5/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5
Data Configuration Overview
Tool ---- WRAN CME:
A tool for NodeB initial configuration, provides an integrated
solution to RAN data configuration
This tool can be used for initial configuration and data
reconfiguration for the NodeB and the RNC
The GUI-based CME provides the operating platform for RAN
data configuration
The forth generation NodeB require the CME V100R008 version
Methods :
manually adding a NodeB
adding a NodeB through a template file
adding a NodeB through a existing configuration file
8/12/2019 IuB Data Configuration
6/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6
Data Configuration Overview
2- IuB NodeB configuration process using CME
Configuring
NodeB
Data
Step1:
Configuring Physical
Equipment
Step 2:
Configuring TransportStep3:
Configuring Local cell
The NodeB data configuration script name is NodeBCfg.xml
8/12/2019 IuB Data Configuration
7/22HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7
Procedure Configuring NodeB Physical Equipment
Physical Equipment Configuration
Create Logical and Physical NodeB
Used for BTS3900&A Used for DBS3900
Choose Macro NodeB Attribute
Add UL baseband
resource group Add
NPMUAdd
NEMU
Add
NPSU
End
Add UTRP
Add UTRP1~9
Add WMPT
Add WBBP
Add UPEA/UPEB B
Add BBU board
Add UEIU
Add RF
Chain/Ring
Add WRFU
Add MRRURHUB/PRRU
Add DL baseband
resource group
Add
UFAN
220V
Add BBU
B
Add RF
Chain/Ring
Add MRRU
RHUB/PRRU
APM30/100/200Add NPMU/NPSU
/NCMU
Antenna
Device
8/12/2019 IuB Data Configuration
8/22
8/12/2019 IuB Data Configuration
9/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9
DBS3900 board configuration
Subrack
number
Subrack
typeSlot number Board type MML Command
0 BBU3900
03 WBBPx/UTRP ADD BRD
45 UTRP ADD BRD
67 WMPT ADD BRD
16 UBF ADD BRD
1819 UPEA/UPEB/UEIU ADD BRD
6 EXT 0 NEMU ADD BRD
7 NPSU 0 NPMUSET
PWRSYSCFG
8 NCMU 0 NCMUSET
PWRSYSCFG
20~254 RRU 0MRRU/PRRU/RH
UBADD RRU
Configuring Physical Equipment
8/12/2019 IuB Data Configuration
10/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10
Configuring Physical Equipment
DBS3900 equipment plane
Right-click the slot numbers, and configure related parameters based on prepared
data so as to add board information of the BBU.
8/12/2019 IuB Data Configuration
11/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11
The RF Configuration Rules of New NodeB
The mechanism of the RF board is the chain and ring mechanism in V200R010.
WRFU of BTS3900
RRU of DBS3900
The steps of configuration the RF board
1.ADD SUBRACK to add RFU cabinet.
2.ADD RRUCHAIN to add chain or ring.
3.SET RRUCHAINBRKPOS to set the break pointoptional)
4.ADD RRU to add WRFU/MRRU/PRRU
5.RMV RRUCHAINBRKPOS to cancel the break point
optional
Right-click the RRU chain to configure the previous five steps in CME software.
8/12/2019 IuB Data Configuration
12/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12
The Backup Mode of RF board
MRRU only support the cold backup mode
The backup mode should be configured in properties of the RRU chain/ring
The hot backup ring can not support the upper layer cascading
The RRUs are of the following types: MRRU, RHUB, PRRU, and WRFU
The RRU Chain of the distributed NodeB supports the configuration of threeRRU types: MRRU, RHUB, and PRRU
the RRU Chain of the macro NodeB supports the configuration of four RRU
types: MRRU, RHUB, PRRU, and WRFU
8/12/2019 IuB Data Configuration
13/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13
TransportConfiguration
Create NodeB
Add UTRP
Add FractionalATM
Add UNI LINKAdd IMA Group
Add WMPT
Add IMA Link
Add Treelink PVCAdd NCP/CCP/IPoA DeviceAdd ALCAP Add CES
Add AAL2 Path
Add Time SlotAcross
Add STM-1 Link
End
Configuring Transport over ATM
Configuring Transport
8/12/2019 IuB Data Configuration
14/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14
Configuring Transport over ATM
Adding NCP
Adding CCP
Adding ALCAP
Adding AAL2path
Adding Tree link PVC
Adding OMCH
8/12/2019 IuB Data Configuration
15/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15
Configuring Transport over IP
TransportConfiguration
Configure the IP Route
Configure the PPP
End
Configure the MLPPPConfigure the timeslot
Cross channelConfigure the Dev IP
Configure the Qos Optional
Configure the SCTP
Configure the IPCP
Configure the OM
Configure the IP Path
8/12/2019 IuB Data Configuration
16/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16
Configuring Transport over IP
Configure the PPP, MP, and Ethernet IP
In a single transport mode, configure one type of transport links.
In hybrid transport mode, configure E1 and FE transport links.
For E1 links, configure PPP or MP
For FE links, configure PPPoE or Ethernet IP
IP networkNodeB RNC
PDH/SDH
IP hybrid transmission
8/12/2019 IuB Data Configuration
17/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17
Configuring Local Cell
Procedure of Local Cell Configuration
Add
Site
Add
Sector
Add
Local
Cell
Local
cell
8/12/2019 IuB Data Configuration
18/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18
Configuring Local Cell Adding Site
Adding a site to the NodeB
Note
A site number within one
NodeB must be unique.
Adding Sector
Adding a sector to the NodeB
Note
A sector number must be unique within one NodeB
Configuring a sector is mainly configuring the corresponding
antenna and feeder system
8/12/2019 IuB Data Configuration
19/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19
Configuring Local Cell
Adding Local Cell
Adding a local cell to the NodeB
Note
Local Cell ID must be unique within thesame NodeB
Negotiated with the peer end RNC
Local Cell ID
Uplink Frequency Downlink Frequency
8/12/2019 IuB Data Configuration
20/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20
IuB RNC configuration process over ATM
Configuring the Physical Layer
Configuring the ATM Traffic Resources
Configuring the Control Plane of the Iub Interface
Configuring the Mapping Between Service Types and TransmissionResources
Configuring the User Plane of the Iub Interface
Configuring the OM Channel over the Iub Interface
http://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-96-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-100-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-101-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-103-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-104-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-104-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-103-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-101-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-100-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-96-u.html8/12/2019 IuB Data Configuration
21/22
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21
IuB RNC configuration process over IP
Configuring the Physical Layer and Data Link Layer (over IP)
Configuring the Control Plane for the Iub Interface (over IP)
Configuring the Mapping Between Service Types and Transmission
Resources
Configuring the User Plane over the Iub Interface (over IP)
Configuring an OM Channel over Iub Interface (over IP)
http://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-106-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-111-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-113-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-114-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-114-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-113-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-111-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-106-u.html8/12/2019 IuB Data Configuration