ITW
Buil
din
g C
om
ponen
ts G
roup,
Inc.
13389 L
akef
ront
Dri
ve
Ear
th C
ity,
MO
63045
(3
14)
344-9
121
Pag
e 1 o
f 1
Docu
men
t ID
:1V
8J9
71-Z
0131084548
Tru
ss F
abri
cato
r:T
ransm
itte
d F
rom
:Jo
b I
den
tifi
cati
on:
Model
Code:
Tru
ss C
rite
ria:
Engin
eeri
ng S
oft
war
e:T
russ
Des
ign L
oad
s:
Leth
erer
Tru
ssps
tilw
ell@
leth
erer
.com
8153
6--K
EENE
LUM
BER
CO /
IBEW
LOC
AL 2
75 -
- 14
0 N
64TH
AVE
COO
PERS
VILL
E, *
*IB
CIB
C200
9/TP
I-20
07(S
TD)
Alpi
ne p
ropr
ieta
ry t
russ
ana
lysi
s so
ftwa
re.
Vers
ion
13.0
2.Ro
of
- 67
.4 P
SF @
1.1
5 Du
rati
onFl
oor
- N/
AWi
nd
- 90
MPH
(AS
CE 7
-05-
Clos
ed)
Note
s:
1.
Dete
rmin
atio
n as
to
the
suit
abil
ity
of t
hese
tru
ss c
ompo
nent
s fo
r th
e
st
ruct
ure
is t
he r
espo
nsib
ilit
y of
the
bui
ldin
g de
sign
er/e
ngin
eer
of
re
cord
, as
def
ined
in
ANSI
/TPI
1
2.
As s
hown
on
atta
ched
dra
wing
s; t
he d
rawi
ng n
umbe
r is
pre
cede
d by
: MO
USR9
71
Deta
ils:
BRC
LBSU
B-A1
0030
05-G
BLLE
TIN-
GABR
ST05
-Su
bmit
ted
by P
PH 0
8:45
:26
07-3
1-20
14
Rev
iewe
r: P
PH$$
#
Re
f
Des
crip
tion
Dra
wing
#
Dat
e
1
330
51--
T1 5
0' C
ommo
n
142
1200
1 0
7/31
/14
2
330
52--
G1 5
0' G
able
142
1200
2 0
7/31
/14
3
330
53-V
1 44
'2"3
Val
ley
142
1200
3 0
7/31
/14
4
330
54-V
2 39
'2"3
Val
ley
142
1200
4 0
7/31
/14
5
330
55-V
3 34
'2"3
Val
ley
142
1200
5 0
7/31
/14
6
330
56-V
4 29
'2"3
Val
ley
142
1200
6 0
7/31
/14
7
330
57-V
5 24
'2"3
Val
ley
142
1200
7 0
7/31
/14
8
330
58-V
6 19
'2"3
Val
ley
142
1200
8 0
7/31
/14
9
330
59-V
7 14
'2"3
Val
ley
142
1200
9 0
7/31
/14
10
330
60--
V8 9
'2"3
Val
ley
142
1201
0 0
7/31
/14
11
330
61--
V9 4
'2"3
Val
ley
142
1201
1 0
7/31
/14
07/3
1/20
14
Phili
p P.
Hed
eman
n
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-4-5 0-4-5
4.8 4.8
10-0-0
Scale =.125"/Ft.13.02.09.0506.20
R=3845 U=0 W=5.5"RL=161/-161
R=3846 U=0 W=5.5"
W8
W6
W5W3
T2T3
PLT TYP. 18 Gauge HS,Wave
MOUSR971 14212001
Design Crit: IBC2009/TPI-2007(STD)
67.4 PSF
REF R971-- 33051 FT/RT=3%(0%)/0(0)
4X14(B8R)
1.5X4
3X4SS0312
5X6
1.5X4
7X8
6X8
SS0312
7X8
1.5X4
5X6
SS0312
3X4
1.5X4
4X14(B8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - T1 50' Common)
JREF- 1V8J971_Z01
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
(a)(a) (a)
(a)
Top chord 2x4 SP 2850f-2.3E :T2, T3 2x4 SP 2400f-2.0E:Bot chord 2x4 SP 2400f-2.0E Webs 2x4 SPF Stud :W3, W8 2x4 SPF #3::W5, W6 2x4 SPF #1/#2::Lt Wedge 2x4 SPF Stud::Rt Wedge 2x4 SPF Stud:
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.
Calculated horizontal deflection is 0.28" due to live load and 0.13" due to deadload.(a) Continuous lateral restraint equally spaced on member.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 -0.53 49.18Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Truss passed check for 20 psf additional bottom chord live load in areas with42"-high x 24"-wide clearance.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.Calculated vertical deflection is 0.77" due to live load and 0.36" due to dead load
at X = 29-10-8.WARNING: Furnish a copy of this DWG to the installation contractor. Special caremust be taken during handling, shipping and installation of trusses. See "WARNING"note below.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
MO-ENG PPH/PPH
50-0-0 Over 2 Supports
25-0-0 25-0-0
2-0-0 2-0-0
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-8 0-0-8
4.8 4.8
10-0-0
Scale =.125"/Ft.13.02.09.0506.20
C13C12C11
PLT TYP. WaveREF R971-- 33052
Design Crit: IBC2009/TPI-2007(STD)
67.4 PSF
0.0 PSF
R=177 PLF U=1 PLF W=50-0-0RL=3/-3 PLF
FT/RT=3%(0%)/0(0)
3X5(D1)
3X6
3X6
5X6
4X6 3X6
3X6
3X5(D1)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - G1 50' Gable)
Note: All Plates Are 1.5X4 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
(a) (a) (a)(a) (a)
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :C11, C12, C13 2x4 SPF #3:
90 mph wind, 15.17 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.Truss spaced at 24.0" OC designed to support 1-0-0 top chord outlookers. Claddingload shall not exceed 3.00 PSF. Top chord must not be cut or notched. See DWGS A10030050109, GBLLETIN0212, & GABRST050109 for gable wind bracing
requirements.(a) 1x4 #3SRB SPF-S or better "L" brace. 80% length of web member. Attach with 8dBox or Gun (0.113"x2.5",min.)nails @ 6" OC. In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.68 49.32Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied perIBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
WARNING: Furnish a copy of this DWG to the installation contractor. Special caremust be taken during handling, shipping and installation of trusses. See "WARNING"note below.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
JREF- 1V8J971_Z01
MOUSR971 14212002
50-0-0 Over 4 Supports
25-0-0 25-0-0
MO-ENG PPH/PPH
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
11-6-0
Scale =.125"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=44-2-3RL=3/-3 PLF
W5
PLT TYP. Wave
JREF- 1V8J971_Z01
FT/RT=3%(0%)/0(0)
3X5(D1)
3X6
3X6
5X6
3X6
3X6
3X5(D1)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V1 44'2"3 Valley)
Note: All Plates Are 1.5X3 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212003
(a)
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :W5 2x4 SPF #3:
90 mph wind, 16.07 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.(a) Continuous lateral restraint equally spaced on member.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.68 43.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load applied perIBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
REF R971-- 33053
MO-ENG PPH/PPH
44-2-3 Over Continuous Support
22-1-2 22-1-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
12-6-0
Scale =.1875"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=39-2-3RL=2/-2 PLF
JREF- 1V8J971_Z01
FT/RT=3%(0%)/0(0)
3X4(D1) 3X5
3X5
5X5
3X5
3X5 3X4(D1)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V2 39'2"3 Valley)
Note: All Plates Are 1.5X3 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212004
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 16.57 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.68 38.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
REF R971-- 33054
MO-ENG PPH/PPH
39-2-3 Over Continuous Support
19-7-2 19-7-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
13-6-0
Scale =.1875"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=34-2-3RL=2/-2 PLF
JREF- 1V8J971_Z01
FT/RT=3%(0%)/0(0)
3X4(D1)
3X5
3X5
4X6(R)
3X5
3X5
3X4(D1)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V3 34'2"3 Valley)
Note: All Plates Are 1.5X3 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212005
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 17.07 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.00 34.18Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
REF R971-- 33055
MO-ENG PPH/PPH
34-2-3 Over Continuous Support
17-1-2 17-1-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
14-6-0
Scale =.25"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=29-2-3RL=2/-2 PLF
JREF- 1V8J971_Z01
FT/RT=3%(0%)/0(0)
2X4(D8R)
5X5
5X7 2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V4 29'2"3 Valley)
Note: All Plates Are 1.5X3 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212006
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 17.57 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 -0.68 28.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
REF R971-- 33056
MO-ENG PPH/PPH
29-2-3 Over Continuous Support
14-7-2 14-7-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
15-6-0
Scale =.3125"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=24-2-3RL=2/-2 PLF
JREF- 1V8J971_Z01
FT/RT=3%(0%)/0(0)
2X4(D8R)
5X5
3X5 2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V5 24'2"3 Valley)
Note: All Plates Are 1.5X3 Except As Shown.
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212007
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 18.07 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.68 23.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
REF R971-- 33057
MO-ENG PPH/PPH
24-2-3 Over Continuous Support
12-1-2 12-1-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8
4.8
16-6-0
Scale =.375"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=19-2-3RL=2/-2 PLF
REF R971-- 33058 FT/RT=3%(0%)/0(0)
2X4(D8R)
1.5X3
1.5X3
5X5
1.5X3 3X5 1.5X3
1.5X3
2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V6 19'2"3 Valley)
JREF- 1V8J971_Z01
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212008
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 18.57 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.68 18.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
MO-ENG PPH/PPH
19-2-3 Over Continuous Support
9-7-2 9-7-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
17-6-0
Scale =.5"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=14-2-3RL=2/-2 PLF
REF R971-- 33059 FT/RT=3%(0%)/0(0)
2X4(D8R)
1.5X3
1.5X3
4X4
1.5X3 1.5X3
1.5X3
2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V7 14'2"3 Valley)
JREF- 1V8J971_Z01
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212009
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 19.07 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.00 14.18Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
MO-ENG PPH/PPH
14-2-3 Over Continuous Support
7-1-2 7-1-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8
4.8
18-6-0
Scale =.5"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=9-2-3
REF R971-- 33060 FT/RT=3%(0%)/0(0)
2X4(D8R)
4X4
1.5X3 2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V8 9'2"3 Valley)
JREF- 1V8J971_Z01
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212010
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 19.57 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.62 8.56Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf, Ct=1.10, Ce=1.00, CATII & Pf=46.20 psf.
MO-ENG PPH/PPH
9-2-3 Over Continuous Support
4-7-2 4-7-2
MI/-/1/-/-/R/-
07/31/2014
**WARNING**
ITW Building Components Group Inc. (ITWBCG) shall not be responsible for any deviation from this design,
READ AND FOLLOW ALL NOTES ON THIS SHEET!
shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs
Trusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and
drawing or cover page listing this drawing, indicates acceptance of professional engineering Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. A seal on this
**IMPORTANT**
any failure to build the truss in conformance with ANSI/TPI 1, or for handling, shipping, installation &
responsibility solely for the design shown. The suitability and use of this design for any structure is
ICC: www.iccsafe.org
practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.
general notes page; ITW-BCG: www.itwbcg.com; TPI: www.tpinst.org; WTCA: www.sbcindustry.com; the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see: This job's
bracing of trusses. Apply plates to each face of truss and position as shown above and on the Joint
FURNISH THIS DESIGN TO ALL CONTRACTORS INCLUDING INSTALLERS.
follow the latest edition of BCSI (Building Component Safety Information, by TPI and WTCA) for safety
shall have bracing installed per BCSI sections B3, B7 or B10, as applicable.
ALPINE
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord
ITW Building Components Group, Inc.
Earth City, MO 63045
0-0-4 0-0-4
4.8 4.8
19-6-0
Scale =.5"/Ft.13.02.09.0506.20
R=136 PLF U=0 PLF W=4-2-3
REF R971-- 33061 FT/RT=3%(0%)/0(0)
2X4(D8R)
3X4
2X4(D8R)
DATE 07/31/14DRW
THIS DWG PREPARED FROM COMPUTER INPUT (LOADS & DIMENSIONS) SUBMITTED BY TRUSS MFR.(81536--KEENE LUMBER CO /IBEW LOCAL 275 -- 140 N 64TH AVE COOPERSVILLE, ** - V9 4'2"3 Valley)
JREF- 1V8J971_Z01
TC LL
TC DL
BC DL
BC LL
TOT.LD.
DUR.FAC. 1.15
SPACING 24.0"
50.4 PSF
7.0 PSF
10.0 PSF
0.0 PSF
67.4 PSF
Design Crit: IBC2009/TPI-2007(STD)
MOUSR971 14212011
PLT TYP. Wave
Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2
90 mph wind, 20.07 ft mean hgt, ASCE 7-05, CLOSED bldg, Located anywhere in roof,CAT II, EXP B, wind TC DL=4.2 psf, wind BC DL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&C member design.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 50 -0.68 3.51Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord live load appliedper IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increase factor for deadload is 1.50.
Unbalanced snow loads have not been considered.
MO-ENG PPH/PPH
4-2-3 Over Continuous Support
2-1-2 2-1-2
MI/-/1/-/-/R/-
07/31/2014
07/31/2014
Building Components Group Inc.
Earth City, MO 63045
07/31/2014
07/31/2014
Building Components Group Inc.
Earth City, MO 63045
07/31/2014
07/31/2014 Building Components Group Inc.
Earth City, MO 63045 07/31/2014
07/31/2014
Building Components Group Inc.
Earth City, MO 63045
07/31/2014