Upload
others
View
5
Download
0
Embed Size (px)
Citation preview
NOZZLE SCHEDULENOZZLE
MARK SIZE QTYSERVICE
NtExt.Proj.
Int.Proj. 41 42 43
WELDS
TYPE SB F1 F2 F3
Flanges
- - - - - - - - - - - - - - -
1
23
4
BILL OF MATERIALITEM QTY. DESCRIPTION MATERIAL
1 2 Clamp SA-182 F316L2 2 Ferrule SA-182 F316L3 2 1/4" - 20 UNC SHCS 1.5" Lg. SA-193 B74 2 1/4" - 20 UNC Nut SA-194 2H
MATERIAL
Tri-ClampB
REVISIONDRAWING NO
A
B
C
DD
C
B
A
1234567
8 7 6 5 4 3 2 1
0JOB ID
PVE-4472SCALE
1:1
SIZE
This drawing and the information herein is confidential, and must no be reproduced or usedin any way without the written permission of Pressure Vessel Engineering Ltd.
See BOM SHEET 1 OF 2
TITLE
DESIGN DATADESIGN CODE:
INTERNAL DESIGN PRESSURE & TEMPERATURE:EXTERNAL DESIGN PRESSURE & TEMPERATURE:
HYDRO TEST PRESSURE & TEMPERATURE:MDMT:
CORROSION ALLOW:PWHT:
RADIOGRAPHY:IMPACT TESTING REQUIRED OR EXEMPTION:
SEISMIC CODE:SERVICE:
WIND CODE:CAPACITY:
WEIGHT EMPTY: WEIGHT FULL:
Pressure Vessel Engineering Ltd120 Randall Drive, Suite BWaterloo, Ontario, CanadaN2V 1C6
Tel. 519-880-9808Fax 519-880-9810
ASME VIII-1, 2007 ed, 2009 add1,500 psi @ 500 °F-2,201 psi @ 70 °F
-40 °F0 inNoneNone
None as per UG-20(f)N/AN/A
N/AN/AN/A0.976 lb
PVEdwg-4472.0
8
REVISON HISTORYREV DATE INITIALS0 08/13/10 CBMRELEASE12345
NOZZLE SCHEDULENOZZLE
MARK SIZE QTYSERVICE
NtExt.Proj.
Int.Proj. 41 42 43
WELDS
TYPE SB F1 F2 F3
Flanges
- - - - - - - - - - - - - - -
.750
A
A
B B
3.250
.500
.281 THRU2 PLCS
SECTION A-A
2.000 Typ.
C
SECTION B-B
.2781.000
.472.200
.153 .115
40°R.685
R.858R.993
DETAIL C SCALE 2 : 1
CL
CL
MATERIAL
Tri-ClampB
REVISIONDRAWING NO
A
B
C
DD
C
B
A
1234567
8 7 6 5 4 3 2 1
0JOB ID
PVE-4472SCALE
1:1
SIZE
This drawing and the information herein is confidential, and must no be reproduced or usedin any way without the written permission of Pressure Vessel Engineering Ltd.
See BOM SHEET 2 OF 2
TITLE
DESIGN DATADESIGN CODE:
INTERNAL DESIGN PRESSURE & TEMPERATURE:EXTERNAL DESIGN PRESSURE & TEMPERATURE:
HYDRO TEST PRESSURE & TEMPERATURE:MDMT:
CORROSION ALLOW:PWHT:
RADIOGRAPHY:IMPACT TESTING REQUIRED OR EXEMPTION:
SEISMIC CODE:SERVICE:
WIND CODE:CAPACITY:
WEIGHT EMPTY: WEIGHT FULL:
Pressure Vessel Engineering Ltd120 Randall Drive, Suite BWaterloo, Ontario, CanadaN2V 1C6
Tel. 519-880-9808Fax 519-880-9810
ASME VIII-1, 2007 ed, 2009 add1,500 psi @ 500 °F-2,201 psi @ 70 °F
-40 °F0 inNoneNone
None as per UG-20(f)N/AN/A
N/AN/AN/A0.976 lb
PVEdwg-4472.0
8
REVISON HISTORYREV DATE INITIALS0 08/13/10 CBMRELEASE12345
Sheet1Drawing View9