INSTALLATION MANUAL
PedigreeTechnologies.com | Support: (701)-499-0022
Temperature Monitoring Add-On
Document ID: IM-TT-TEMP-ADDLast Updated: April 3, 2019
Pedigree Technologies recommends using a professional installer for optimal results. Please let your Pedigree Technologies representative suggest a provider if
you need help with your hardware installations.
2
Prerequisites
PedigreeTechnologies.com | Support: (701)-499-0022
Temperature Monitoring Add-On
Required Information • Name of asset (ex: Reefer #20) • Detailed information about the asset (year, make, model, VIN, license plate, etc.) • State, area, organization, or group the asset belongs to (ex: North Region, MN tankers, etc.) • ESN of each device to be installed (ESN is found on the back of each unit with a barcode)
Required Equipment
Required Tools
Drill and assorted drill bits (to access device and/or secure cabling)Slotted and Philips Torx bits (to access device and/or secure cabling)Butane Torch or Heat Gun (if using heat shrink tubing at wire connections)Rubber Grommet (if drilling new hole for cabling)Silicone sealant (if running cabling through new or existing hole)
Temperature Sensor
Before You Begin
TURN TO THE LAST PAGE - WRITE DOWN THE REQUIRED INFORMATION!!!
• Find appropriate location for installation • Midway or evenly spaced between tranported items• On a wall not obstruction by objects or directly in front of air vents• Near other existing or factory installed sensors is a good location
• Route cables through existing hole to send cable to LMU• If new hole is required, it should be insulated with rubber grommet and silicone sealent• Secure cabling to trailer all along route to LMU• Additional hardware may be required
Temperature SensorExtention Kit
OR
1 - Digital Temp Sensor5 - Cable Clamps5 - Screws5 - Cable Ties1 - Plastic Bushing4 - Heat Shrink with Built-
in Solder Disc1 - Instructions for Heat
Shrink Termination
PedigreeTechnologies.com | Support: (701)-499-0022
3
Installation Steps, ContinuedInstallation
Temperature Monitoring Add-On
MOUNT TEMPERATURE SENSORThe temperature sensor should be mounted in the desired location with included hardware.
ROUTE TO TELEMATICS DEVICERoute the temperature sensor cable to the asset’s telematics device.
CONNECT SENSOR WIRESConnect the 1BB Data wire and 1BB Ground wire from the tempearture sensor to the corresponding wires based on the telematics device type. Use the self-sealing and soldering waterproof connectors included in the hardware kit.
DATANAB SENSORIf your sensor looks like this, (stainless probe, no boot) follow the Datanab sensor instructions for wire colors and connections.
CALAMP SENSORIf your sensor looks like this, (stainless probe with boot) follow the Calamp sensor instructions for wire colors and connections.
CALAMP WIRE COLORS/FUNCTIONSWHITE = DATABLACK= GROUNDBLUE = ENABLERED = OUT
DATANAB WIRE COLORS/FUNCTIONSRED = DATABLACK = GROUNDWHITE = ENABLEGREEN/WHITE = OUT
PedigreeTechnologies.com | Support: (701)-499-0022
4
Temperature Monitoring Add-On
Telematics Device WiringTELEMATICS DEVICE WIRINGThe following section describes each style of telemtatics device you could be connecting a temperature sensor to. Follow the wiring schematic for the appropriate telematics device.
LMU 26xx/27xx DEVICES1BB data wire is WHITE/BLUE on pin 171BB ground wire is BLACK on pin 16
TTU 28xx DEVICES1BB data wire is WHITE/BLUE1BB ground wire is shared with the BLACK chassis ground of the TTU 2830
WHITE/BLUE = 1BB DATA
BLACK = 1BB GROUND
LMU 42xx SERIES DEVICES1BB data wire is GREEN/BLACK on pin 8 or the 22-pin I/O harness1BB ground wire is BLACK on pin 9 of the 22-pin I/O harness
View looking into LMU
View looking into LMU
PedigreeTechnologies.com | Support: (701)-499-0022
5
Temperature Monitoring Add-On
Calamp Digital Temperature Sensor Diagrams
Sensor 1 Sensor 2 Sensor 3
1W
GND
LMU
Connect Blue wire to GND on first sensor.
Connect Red of previous sensor to Blue of next sensor.
Leave Red of last sensor disconnected.
Multiple Calamp Sensors = White Wire
Single Sensor
1W
GND
LMU
Tie Blue and Black sensor wires before connecting to ground
Single Calamp Sensor
Leave Red wire of sensor disconnected.
= White Wire
PedigreeTechnologies.com | Support: (701)-499-0022
6
Temperature Monitoring Add-On
Datanab Digital Temperature Sensors Diagrams
Sensor 1 Sensor 2 Sensor 3
1W
GND
LMU
Connect White wire to GND on first sensor.
Connect Green/White of previous sensor to White of next
sensor.
Leave Yellow/Green of last sensor disconnected.
Multiple Datanab Sensors= White Wire
Single Sensor
1W
GND
LMU
Tie White and Black sensor wires before connecting to ground
Single Datanab Sensor
Leave Yellow/Green wire of sensor disconnected.
= White Wire
Testing / Confirmation Steps
PedigreeTechnologies.com | Support: (701)-499-0022
Temperature Monitoring Add-On
FINAL STEPCall Pedigree Technologies installation support to confirm and finalize the installation.
701-499-0022You will be prompted for the following information during the set up process
• Device ESN
• Name of Asset (ex. Goosneck 51)
• Trailer make and model
• VIN #
• License plate #
• Mileage Hours
REMOVE POWERRemove power from the LMU/TTU by powering down the trailer/reefer and let the device go to sleep and all lights on the LMU are off.