12
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA PHONE: (303) 442-1255 FAX: (970) 535-3114 E-MAIL: [email protected] WEBSITE: www.itlboulder.com NVLAP LAB CODE: 200925-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 4 3 2 1 0 1 2 2.75 1.75 0 1 2 3 4 5 6 7 2.25 3.75 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting Heights House Side Street Side Maximum Candela point 1/2 Maximum Candela trace Approved Checked M KLOPF N WHITE Lighting Engineer 5 2 1 .5 .2 .1 .05 .02 .01 .005 .005 .005 .005 IES Classification: Medium, Noncutoff, Type II REPORT NUMBER: ITL83798 ISSUE DATE: 12/11/14 PAGE: 1 OF 8 PREPARED FOR: RAB LIGHTING, INC. CATALOG NUMBER: TBLED2T150 (TYPE II) LUMINAIRE: CAST GRAY PAINTED FINNED METAL HOUSING WITH CAST GRAY PAINTED METAL ACCESS DOOR, 2 CAST METAL CIRCUIT BOARD MOUNTING BASES, 4 CIRCUIT BOARDS EACH WITH 1 LED, MOLDED 3-PIECE PLASTIC REFLECTOR WITH SPECULAR FINISH AND 1 APERTURE PER LED, CLEAR FLAT GLASS LENS IN CAST GRAY PAINTED METAL FRAME. LAMPS: FOUR WHITE MULTI-CHIP LIGHT EMITTING DIODES (LEDS), TILTED 54- DEGREES FROM VERTICAL BASE-UP POSITION AND CANTED 77-DEGREES FROM STRAIGHT AHEAD. INPUT ELECTRICAL: 120.0 VOLTS, 163.6 WATTS, 1.37 AMPS LED DRIVER: RAB RD-160-Q1050 NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT. TEST PROCEDURE: IESNA LM-79-08 TEST DISTANCE = 35.0 FEET 11 13/16 15 11/16 27 13/16 14 3/8

ISOFOOTCANDLE LINES OF HORIZONTAL … · the light center of the industry since 1955 independent testing laboratories, inc. 4066 camelot circle, longmont, co 80504 usa phone: (303)

Embed Size (px)

Citation preview

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATIONValues based on 25 foot mounting height.

4

3

2

1

0

1

2

2.75

1.75

0 1 2 3 4 5 6 72.25 3.75Longitudinal Distance in Units of Mounting Heights

Tra

nsve

rse

Dis

tanc

e in

Uni

ts o

f Mou

ntin

g H

eigh

tsH

ouse

Sid

eS

tree

t Sid

e

Maximum Candela point1/2 Maximum Candela trace

Approved

Checked M KLOPF

N WHITELighting Engineer

5

2

1

.5

.2.1

.05

.02

.01

.005

.005

.005

.005

IES Classification: Medium, Noncutoff, Type II

REPORT NUMBER: ITL83798ISSUE DATE: 12/11/14 PAGE: 1 OF 8PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)LUMINAIRE: CAST GRAY PAINTED FINNED METAL HOUSING WITH CAST GRAY PAINTED METAL ACCESS DOOR, 2 CAST METAL CIRCUIT BOARD MOUNTING BASES, 4 CIRCUIT BOARDS EACH WITH 1 LED, MOLDED 3-PIECE PLASTIC REFLECTOR WITH SPECULAR FINISH AND 1 APERTURE PER LED, CLEAR FLAT GLASS LENS IN CAST GRAY PAINTED METAL FRAME.LAMPS: FOUR WHITE MULTI-CHIP LIGHT EMITTING DIODES (LEDS), TILTED 54- DEGREES FROM VERTICAL BASE-UP POSITION AND CANTED 77-DEGREES FROM STRAIGHT AHEAD.INPUT ELECTRICAL: 120.0 VOLTS, 163.6 WATTS, 1.37 AMPSLED DRIVER: RAB RD-160-Q1050NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT.TEST PROCEDURE: IESNA LM-79-08TEST DISTANCE = 35.0 FEET

11 13/1615 11/16

27 13/16

14 3/80°

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

30° 0° 30°

60°

90°

120°

150°180°

90°

60°

HOUSESIDE

STREETSIDE

CA

ND

EL

A

MAXIMUM PLANE AND MAXIMUM CONE PLOTS OF CANDELA

VERTICAL PLANE THROUGH MAXIMUM CANDELA CONE THROUGH MAXIMUM CANDELA

4600

9200

13800

70.0 (Degrees Vertical) 76.5 (Degrees Horizontal) = 13702

REPORT NUMBER: ITL83798ISSUE DATE: 12/11/14 PAGE: 2 OF 8PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)LUMINAIRE: CAST GRAY PAINTED FINNED METAL HOUSING WITH CAST GRAY PAINTED METAL ACCESS DOOR, 2 CAST METAL CIRCUIT BOARD MOUNTING BASES, 4 CIRCUIT BOARDS EACH WITH 1 LED, MOLDED 3-PIECE PLASTIC REFLECTOR WITH SPECULAR FINISH AND 1 APERTURE PER LED, CLEAR FLAT GLASS LENS IN CAST GRAY PAINTED METAL FRAME.LAMPS: FOUR WHITE MULTI-CHIP LIGHT EMITTING DIODES (LEDS), TILTED 54- DEGREES FROM VERTICAL BASE-UP POSITION AND CANTED 77-DEGREES FROM STRAIGHT AHEAD.INPUT ELECTRICAL: 120.0 VOLTS, 163.6 WATTS, 1.37 AMPSLED DRIVER: RAB RD-160-Q1050NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT.TEST PROCEDURE: IESNA LM-79-08TEST DISTANCE = 35.0 FEET

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 3 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

COEFFICIENTS OF UTILIZATION AND FLUX DISTRIBUTION

PERCENT LUMENS OF FIXTURE

DOWNWARDSTREET SIDE 13973 79.2

DOWNWARDHOUSE SIDE 3674 20.8

DOWNWARDTOTAL 17647 100.0

UPWARDSTREET SIDE 0 0.0

UPWARDHOUSE SIDE 0 0.0

UPWARDTOTAL 0 0.0

TOTALFLUX 17647 100.0

EFFICACY = 107.9 lm/W

ALL CANDELA AND LUMENS IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY.THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTELUMEN OUTPUT OF THIS LUMINAIRE SAMPLE.

0 1 2 3 4 50.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

Street Width / Mounting Height

Coefficients of Utilization

HOUSE SIDE

STREET SIDE

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 4 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

FLUX DISTRIBUTION BY SOLID ANGLE

(PER IESNA TM-15-11, LUMINAIRE CLASSIFICATION SYSTEM FOR OUTDOOR LUMINAIRES)

PERCENT BUG OF ZONE LUMENS FIXTURE RATINGS

FORWARD LIGHT 13973. 79.2 FL ( 0- 30) 1524.3 8.6 FM ( 30- 60) 7284.7 41.3 FH ( 60- 80) 4981.4 28.2 G2 FVH( 80- 90) 183.0 1.0 G2

BACK LIGHT 3674. 20.8 BL ( 0- 30) 1040.0 5.9 B3 BM ( 30- 60) 1830.4 10.4 B2 BH ( 60- 80) 780.2 4.4 B2 G2 BVH( 80- 90) 23.2 0.1 G1

UPLIGHT 0. 0.0 UL ( 90-100) 0.0 0.0 U0 UH (100-180) 0.0 0.0 U0

TRAPPED LIGHT 0. 0.0

TOTAL FLUX 17647. 100.0

BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS (PER ADDENDUM A FOR IESNA TM-15-11)

BUG RATING: B3 U0 G2

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 5 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

CANDELA TABULATION

STREET SIDE LATERAL ANGLE 0.0 5.0 15.0 25.0 35.0 45.0 55.0 65.0 75.0 76.5 85.0 || 180.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 175.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 165.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 155.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 145.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 135.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 125.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 115.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 105.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 95.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 92.5 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 90.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 87.5 0. 0. 1. 3. 7. 12. 20. 27. 69. 63. 49. 85.0 8. 8. 9. 14. 26. 43. 136. 281. 417. 399. 261. V 82.5 17. 16. 18. 27. 63. 206. 526. 1147. 1528. 1449. 961. E 80.0 25. 24. 29. 76. 234. 604. 1534. 3232. 4123. 4151. 2956. R 77.5 43. 39. 55. 157. 558. 1421. 2988. 5050. 6671. 6795. 4691. T 75.0 114. 125. 215. 492. 1194. 2509. 4188. 6469. 9419. 9230. 6542. I 72.5 428. 447. 707. 1186. 2112. 3492. 4962. 8031.12297.12407. 9362. C 70.0<< 950. 938. 1371. 1990. 2899. 4128. 5711. 9647.13552.13702.11017. A 67.5 | 1619. 1467. 1914. 2571. 3427. 4686. 6767.11400.13209.12960.10552. L 65.0 | 2134. 1924. 2303. 2976. 3866. 5363. 7830.12052.11787.11281. 9690. 62.5 | 2457. 2251. 2580. 3339. 4373. 6239. 9120.11711.10432.10136. 9338. A 60.0 | 2747. 2562. 2865. 3744. 5051. 7190.10127.11419. 9556. 9441. 8760. N 57.5 | 3072. 2915. 3220. 4281. 5865. 8270.10522.10486. 8794. 8596. 8223. G 55.0 | 3533. 3348. 3673. 4912. 6609. 8977.10585. 9558. 8094. 7884. 7809. L 52.5 | 4113. 3886. 4211. 5543. 7488. 9319.10086. 8699. 7411. 7362. 7348. E 50.0 | 4587. 4408. 4718. 6218. 7950. 9237. 9372. 7982. 6871. 6891. 6828. 47.5 | 5138. 4977. 5240. 6630. 8196. 8983. 8642. 7184. 6432. 6460. 6391. 45.0 | 5630. 5368. 5517. 6732. 8313. 8771. 7928. 6412. 6035. 6083. 5966. 42.5 | 5826. 5562. 5548. 6598. 7735. 8339. 7055. 5928. 5642. 5643. 5494. 40.0 | 5705. 5527. 5354. 5979. 6755. 7437. 6191. 5428. 5316. 5378. 5002. 37.5 | 5507. 5286. 5072. 5425. 6025. 6102. 5425. 5018. 5031. 4847. 4656. 35.0 | 5204. 5080. 4745. 4898. 5262. 5385. 4848. 4718. 4580. 4705. 4370. 32.5 | 4944. 4798. 4486. 4405. 4628. 4592. 4387. 4369. 4420. 4452. 4169. 30.0 | 4680. 4559. 4180. 3897. 4211. 4075. 3982. 4115. 4147. 4147. 3985. 25.0 | 4268. 4154. 3835. 3486. 3494. 3495. 3668. 3766. 3796. 3794. 3712. 20.0 | 3841. 3796. 3588. 3401. 3275. 3403. 3383. 3506. 3510. 3493. 3456. 15.0 | 3740. 3732. 3608. 3485. 3368. 3302. 3288. 3225. 3190. 3190. 3189. 10.0 | 3767. 3790. 3742. 3599. 3523. 3412. 3325. 3244. 3187. 3194. 3187. 5.0 | 3771. 3797. 3814. 3705. 3638. 3565. 3488. 3431. 3383. 3392. 3400. 0.0 | 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. | || | PLANE OF MAXIMUM CANDELA | CONE OF MAXIMUM CANDELA

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 6 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

CANDELA TABULATION

HOUSE SIDE LATERAL ANGLE 90.0 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 180.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 175.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 165.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 155.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 145.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 135.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 125.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 115.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 105.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 95.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 92.5 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 90.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 87.5 50. 12. 9. 5. 3. 1. 0. 0. 0. 0. 0. 85.0 202. 65. 31. 16. 9. 5. 3. 2. 1. 0. 0. V 82.5 681. 270. 97. 40. 27. 13. 6. 4. 3. 2. 2. E 80.0 2004. 870. 158. 104. 61. 28. 12. 7. 5. 4. 5. R 77.5 3023. 1695. 187. 118. 90. 58. 26. 12. 10. 9. 10. T 75.0 4314. 2549. 291. 139. 103. 93. 41. 18. 15. 13. 16. I 72.5 6404. 3585. 412. 179. 144. 108. 58. 25. 18. 17. 20. C 70.0<< 7862. 4669. 777. 225. 156. 113. 57. 36. 23. 19. 21. A 67.5 | 8130. 5250. 1430. 438. 190. 165. 59. 38. 27. 20. 19. L 65.0 | 8127. 6191. 2260. 632. 210. 150. 75. 50. 32. 23. 22. 62.5 | 8333. 7170. 3045. 815. 257. 162. 105. 60. 34. 26. 23. A 60.0 | 8117. 7202. 3331. 991. 336. 183. 117. 61. 44. 33. 27. N 57.5 | 7774. 7140. 3372. 1255. 458. 230. 161. 87. 74. 42. 34. G 55.0 | 7388. 6621. 3264. 1639. 615. 255. 217. 135. 103. 49. 43. L 52.5 | 6838. 6214. 3348. 1972. 673. 360. 188. 182. 136. 89. 63. E 50.0 | 6247. 5744. 3642. 2132. 769. 412. 297. 168. 121. 108. 70. 47.5 | 5904. 5557. 3946. 2312. 935. 494. 355. 265. 146. 89. 74. 45.0 | 5580. 5433. 4049. 2454. 1116. 606. 375. 267. 185. 131. 62. 42.5 | 5241. 5201. 3951. 2541. 1298. 699. 458. 256. 149. 121. 65. 40.0 | 4870. 4860. 3860. 2627. 1546. 838. 488. 341. 165. 113. 76. 37.5 | 4574. 4554. 3795. 2744. 1815. 1022. 572. 366. 244. 177. 108. 35.0 | 4349. 4362. 3756. 2849. 2011. 1258. 763. 429. 259. 204. 196. 32.5 | 4162. 4228. 3708. 2940. 2141. 1487. 1002. 619. 366. 292. 310. 30.0 | 3995. 4058. 3663. 2996. 2298. 1667. 1218. 843. 573. 485. 466. 25.0 | 3719. 3770. 3565. 3057. 2554. 2008. 1606. 1211. 924. 881. 876. 20.0 | 3466. 3492. 3375. 3096. 2675. 2311. 1939. 1614. 1457. 1402. 1406. 15.0 | 3191. 3209. 3159. 3082. 2867. 2618. 2446. 2272. 2198. 2188. 2190. 10.0 | 3177. 3186. 3171. 3221. 3201. 3111. 3028. 3009. 3044. 3117. 3152. 5.0 | 3394. 3417. 3426. 3466. 3469. 3485. 3543. 3598. 3670. 3685. 3707. 0.0 | 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. 3783. | | | CONE OF MAXIMUM CANDELA

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 7 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

5-DEGREE 10-DEGREEZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY 0- 5 87 0- 10 331 5- 10 244 0- 20 1192 10- 15 372 0- 30 2564 15- 20 489 0- 40 4682 20- 25 615 0- 50 7887 25- 30 758 0- 60 11679 30- 35 938 0- 70 15369 35- 40 1180 0- 80 17441 40- 45 1486 0- 90 17647 45- 50 1719 0-100 17647 50- 55 1860 0-110 17647 55- 60 1933 0-120 17647 60- 65 1913 0-130 17647 65- 70 1777 0-140 17647 70- 75 1355 0-150 17647 75- 80 717 0-160 17647 80- 85 192 0-170 17647 85- 90 14 0-180 17647 90- 95 0 95-100 0100-105 0105-110 0110-115 0115-120 0120-125 0125-130 0130-135 0135-140 0140-145 0145-150 0150-155 0155-160 0160-165 0165-170 0170-175 0175-180 0

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83798 PAGE: 8 OF 8ISSUE DATE: 12/11/14PREPARED FOR: RAB LIGHTING, INC.

ADDRESS: 170 LUDLOW AVE. NORTHVALE, NJ 07647

THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BYTHE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENTBY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83807 Page 1 of 4DATE: 12/19/14PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)

ADDRESS: 170 LUDLOW AVE. NORTHVALE, NJ 07647

LUMINAIRE: CAST GRAY PAINTED FINNED METAL HOUSING WITH CAST GRAY PAINTED METAL ACCESS DOOR, 2 CAST METAL CIRCUIT BOARD MOUNTING BASES, 4 CIRCUIT BOARDS EACH WITH 1 LED, MOLDED 3-PIECE PLASTIC REFLECTOR WITH SPECULAR FINISH AND 1 APERTURE PER LED, CLEAR FLAT GLASS LENS IN CAST GRAY PAINTED METAL FRAME.

LAMP: FOUR WHITE MULTI-CHIP LIGHT EMITTING DIODES (LEDS), TILTED 54-DEGREES FROM VERTICAL BASE-UP POSITION AND CANTED 77-DEGREES FROM STRAIGHT AHEAD.

DRIVER: RAB RD-160-Q1050

NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120.0 AND 277.0 VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT.

Calibration Due: INSTRUMENTS: Associated Power Technologies APT5040 AC Power Source N/A Yokogawa WT210 Digital Power Meter #8 12/31/14 Ocean Optics QE65000 Spectroradiometer 07/14/15 ITL 2.0m Diameter Integrating Sphere S20-2, 4PI Geometry 07/14/15

OBJECT OF TEST: Measure the Total Radiant Flux*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Indices (CRIa,1-14), Chromaticity Coordinates (x,y; u’v’), ANSI C78.377 Duv, Scotopic / Photopic Ratio, and electrical data including ANSI C82.77-2002 Power Factor (PF) and Total Harmonic Distortion (THD) to the test sample. Report Off-State Power. Measure electrical data including Total Harmonic Distortion (THD) at maximum nominal rated voltage.

PROCEDURE: The test sample was provided by the customer and had an unknown number of operating hours. The test sample was mounted inside the integrating sphere and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 120.0 VAC input. Electrical data was also recorded at maximum nominal rated input voltage (277.0 VAC). All testing performed in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM-79-08. All data are traceable to the National Institute of Standards and Technology. Off-State Power was reported with no voltage applied to the sample.

*NOTE: Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.

RESULTS: (continued subsequent pages) THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

Sphere Lab SupervisorApproved

Checked N THOMAS

P O’CONNOR

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83807 Page 4 of 4DATE: 12/19/14PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)

CIE Chromaticity Diagram

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83807 Page 2 of 4DATE: 12/19/14PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)

RESULTS:

SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u’ Chromaticity Ordinate v’ Correlated Color Temp CCT (K) ANSI C78.377-2008 Duv Scotopic / Photopic Lumen Ratio Total Radiant Flux (milliWatts) ELECTRICAL Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)

Off-State Power (Watts)

ELECTRICAL AT MAX NOMINAL INPUT Input Voltage (Volts AC) Input Current (Amps AC) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%)

CIE 1931 2 degree 0.3528 0.3654 CIE 1976 2 degree 0.2113 0.4924 4777 0.004 1.746 52442 * 120.0 1.37 163.7 99.6 4.8 0.2

0.0

277.0 0.634 160.3 91.3 13.8 0.1

*NOTE: Proper calibration of integrating spheres for measuring total flux output of non-directional samples will produce reliable, repeatable results within the calibration tolerances of the equipment used. However, measurement of test samples with significant self absorption and/or directional output, even when these effects are compensated for, are likely to have a greater variation in results compared to the flux output calculated from a goniophotometric exploration since these artifacts do not affect the goniophotometric results.

COLOR RENDERING INDICES CRI Ra (Average 1-8) R1 Light greyish red R2 Dark greyish yellow R3 Strong yellowish green R4 Moderate yellowish green R5 Light bluish green R6 Light blue R7 Light violet R8 Light reddish purple R9 Strong red R10 Strong yellow R11 Strong green R12 Strong blue R13 Light yellowish pink (skin) R14 Moderate olive green (leaf)

72 70 77 82 72 70 68 83 58 -24 45 68 39 70 90

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL83807 Page 3 of 4DATE: 12/19/14PREPARED FOR: RAB LIGHTING, INC.CATALOG NUMBER: TBLED2T150 (TYPE II)

RESULTS:

Wavelength mW per nm Wavelength mW per nm Wavelength mW per nm 380 1.384 515 187.805 650 118.916 385 1.497 520 214.301 655 106.265 390 1.716 525 235.713 660 94.757 395 2.249 530 252.553 665 84.147 400 3.280 535 264.812 670 74.599 405 5.505 540 273.987 675 65.874 410 10.349 545 281.072 680 58.055 415 20.230 550 285.809 685 50.978 420 38.294 555 289.571 690 44.716 425 68.706 560 292.512 695 39.245 430 114.934 565 294.119 700 34.445 435 174.756 570 294.297 705 30.151 440 248.449 575 293.241 710 26.390 445 345.728 580 290.750 715 23.017 450 401.809 585 286.115 720 20.157 455 332.432 590 279.639 725 17.595 460 216.147 595 271.161 730 15.306 465 147.831 600 261.341 735 13.340 470 103.967 605 249.776 740 11.642 475 71.752 610 236.609 745 10.145 480 56.516 615 222.363 750 8.922 485 53.364 620 207.199 755 7.832 490 58.045 625 191.402 760 6.853 495 72.090 630 176.367 765 6.014 500 95.560 635 161.258 770 5.267 505 125.292 640 146.650 775 4.619 510 156.913 645 132.414 780 4.036

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

0.0

85.0

170.0

255.0

340.0

425.0

Out

put (

mW

/nm

)

380.0 420.0 460.0 500.0 540.0 580.0 620.0 660.0 700.0 740.0 780.0Wavelength (nm)

Output vs. Wavelength