6
Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning mode). R-type 2488-01E 2433-06D (mounted on module 137) 2395-17E (mounted on module 137) 2439-15D Sample set number: 962 (P2-2007). Phi type Required peak dose: 3E15 p cm -2 , single hit spot. 2433-12B 2433-07A (mounted on module 136) 2395-31C (mounted on module 136) 2313-17B Sample set number: 966 (P2-2007).

Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

Embed Size (px)

Citation preview

Page 1: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

Irradiation logbook:

Detectors names (inserted from top to bottom in the holder):Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning mode).R-type2488-01E2433-06D (mounted on module 137)2395-17E (mounted on module 137)2439-15DSample set number: 962 (P2-2007).Phi type Required peak dose: 3E15 p cm-2, single hit spot.2433-12B2433-07A (mounted on module 136)2395-31C (mounted on module 136)2313-17BSample set number: 966 (P2-2007).

Page 2: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

2433-07A

0

0.2

0.4

0.6

0.8

1

1.2

1.4

-1000 -800 -600 -400 -200 0

Bias (V)

1/C

² (p

F-2

)

After irradiation

Pre-irradiated

Module 136 ()

2413-17B

0

0.2

0.4

0.6

0.8

1

1.2

1.4

-1000 -800 -600 -400 -200 0

Bias (V)

1/C

² (p

F-2

)

Pre-irradiated

After irradiation

CV measurements (Note: VFD is not a fixed values, it varies with the non-homogeneous irradiation level, see fluence profile!).

P-type

N-type

Page 3: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

Module 136 ()IV measurements.P-type

2313-17B

1

10

100

1000

-1000 -800 -600 -400 -200 0

Bias (V)

I (µ

A) After irr. n-type

N-type2433-07A

1

10

100

1000

-1000 -800 -600 -400 -200 0

Bias (V)

I (µ

A)

After irr. p-type

Comparison n and p

1

10

100

1000

-1000 -800 -600 -400 -200 0

Bias (V)

I (µ

A)

After irr. n-type

After irr. p-type

Page 4: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

2433-06D

0

0.2

0.4

0.6

0.8

1

1.2

-600 -500 -400 -300 -200 -100 0

Bias (V)

1/C

² (p

F-2

)

After irradiation

2395-17E

0

0.2

0.4

0.6

0.8

1

1.2

1.4

-600 -500 -400 -300 -200 -100 0

Bias (V)

1/C

² (p

F-2

)After irradiation

P-type

N-type

Module 137 (R)

CV measurements (Note: VFD is not a fixed values, it varies with the non-homogeneous irradiation level, see fluence profile!).

Page 5: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

2433-06D

0

1

10

100

1000

-600 -500 -400 -300 -200 -100 0

Bias (V)

I (µ

A)

After irradiation

Pre-irr.

P-type N-type

2395-17E

1

10

100

1000

-600 -500 -400 -300 -200 -100 0

Bias (V)

I (µA

)

After irradiation

Comparison n and p

1

10

100

1000

-600 -500 -400 -300 -200 -100 0

Bias (V)

I (µA

)

P-type

N-type

Module 137 (R) IV measurements.

Page 6: Irradiation logbook: Detectors names (inserted from top to bottom in the holder): Required dose: 1.5E15 p cm-2, homogeneous on half of the detectors (scanning

R-detectors irradiation profile

-detectors irradiation profile