    IONOS-NMS P5

    EMS Management

    Installation and User Guide

    253 153 962-05

    May 2011 – Issue 05

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    2/205

    LIST OF CHANGES

    (A new edition replaces all previous versions)

    N° Date Change description Page

    253 153 962-05 

    3 000 322 859 000 03

    October 2008 Creation of original user guide forversion P5.3 

    All pages

    253 153 962-05 

    3 000 322 859 000 04

    April 2009 Update of user guide for version P5.4 All pages 

    253 153 962-05 

    3 000 322 859 000 05

    May 2011 Update of user guide for version P5.5 All pages 

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    3/205

    WARNING

    SAGEMCOM follows all the technical evolutions assiduously and continuously seeks the improvement of itsproducts so as to make some profit fully its customers.

    Consequently, it thus assumes the right to make evolve without notice its documentation.

    ENVIRONMENT

    Preservation of the environment as part of a sustainable development logic is an essential concern ofSAGEMCOM.

    The desire of SAGEMCOM is to operate systems observing the environment and consequently it has decidedto integrate environmental performances in the life cycle of its products, from manufacturing to commissioning,use and elimination.

    PACKING :

    The presence of the logo (green dot) means that a contribution is paid to an approvednational organisation to improve packaging recovery and recycling infrastructures.

    To facilitate recycling, please respect the sorting rules set up locally for this kind ofwaste

    BATTERIES : 

    If your product contains batteries, they must be disposed of at appropriate collection points.

    THE PRODUCT :

    The crossed-out waste bin stuck on the product (or on its accessories) means that the productbelongs to the family of electrical and electronic equipment.

    In this respect, the European regulations ask you to dispose of it selectively :•  At sales points in the event of the purchase of similar equipment.•  At the collection points made available to you locally (drop-off centre, selective

    collection, etc.).

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    4/205

    TABLE OF CONTENTS

    LIST OF FIGURES .............................................................................................................................................................9  

    LIST OF ABBREVIATIONS ............................................................................................................................................12  

    TYPOGRAPHICAL CONVENTIONS.............................................................................................................................13  

    GLOSSARY.......................................................................................................................................................................14  

    1. SYSTEM INSTALLATION AND MANAGEMENT...................................................................................................15  

    1.1 - GENERAL INFORMATION..........................................................................................................................................15  1.1.1 - IONOS-NMS ..................................................................................................................................................15  1.1.2 - Architecture ....................................................................................................................................................16   

    1.1.2.1 - General architecture .................................................................................................................................................16  1.1.2.2 - Software architecture  ...............................................................................................................................................17 

    1.1.3 - Workstations ..................................................................................................................................................17   

    1.1.4 - Man-Machine Interface (MMI) .....................................................................................................................17  1.2 - INSTALLING THE CD WITH WINDOWS .....................................................................................................................18  

    1.2.1 - To install the Server + Client Applications   ................................................................................................18 1.2.1.1 - To install the Server Application (with Client) .......................................................................................................18  1.2.1.2 - To install the Client Application ...............................................................................................................................20  1.2.1.3 - To install the Proxy Application ...............................................................................................................................21  1.2.1.4 - To install the NMSperftool Application ...................................................................................................................22  

    1.2.2 - To install LCT application for equipment (FMX, Sagem-Link, FSP2000, FSP3000, ADR155E) ......22 1.2.2.1 - To install LCT application for equipment of type FMX, Sagem-Link, FSP2000, FSP3000 ............................22  1.2.2.2 - To install LCT application for equipment ADR155E.............................................................................................23  

    1.2.3 - Available configurations on Server IONOS-NMS .....................................................................................24  1.2.3.1 - To configure TFTP server ........................................................................................................................................24  1.2.3.2 - To configure IP address of the server seen by the equipment ...........................................................................24  1.2.3.3 - To configure the backup directories .......................................................................................................................24  1.2.3.4 - To configure the HTTP Proxy Function .................................................................................................................25  1.2.3.5 - To configure the function Traps Forward...............................................................................................................25  1.2.3.6 - To configure the parameters associated with the collection of performance ...................................................25  1.2.3.7 - To authorize the data entry of the accents and the special characters in the "Name" of the equipment .....27 1.2.3.8 - To inhibit control on the name of cross-connections in the audit of the equipment.........................................27  1.2.3.9 - To configure the time interval between IONOS-NMS and equipment ...............................................................28  1.2.3.10 - To configure the performance parameters used by equipment .......................................................................28  1.2.3.11 - To configure the IONOS-NMS server name .......................................................................................................28  1.2.3.12 - To configure the send of mail on alarm change .................................................................................................28  1.2.3.13 - To configure the timers used for the send of mail ..............................................................................................29  1.2.3.14 - To configure the send of mail on critical alarm..................................................................................................29  1.2.3.15 - To configure the send of mail on a “system” alarm...........................................................................................30  1.2.3.16 - To configure the send of mail on a specific event type .....................................................................................30  

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    5/205

    1.2.3.34 - To configure the SNMP trap generator................................................................................................................41  1.2.3.35 - Configuration file to display the long name of the trail(s) in relation to its alarm pk ......................................43  1.2.3.36 - To run the getTrailLongNames script...................................................................................................................44  1.2.3.37 - To configure the FMX backup configuration file .................................................................................................44  

    1.2.3.38 - To configure the user rights to perform actions from the Federator application ............................................45  1.2.4 - Available configurations on Client IONOS-NMS ......................................................................................46  1.2.4.1 - To configure the help on line ...................................................................................................................................46  1.2.4.2 - To configure Internet Explorer to use HTTP Browser on the equipment of type ADR....................................46  1.2.4.3 - To configure Internet Explorer to use HTTP Proxy ..............................................................................................47  1.2.4.4 - To inhibit the data entry of spaces in the M1400 name of the equipment ........................................................47  1.2.4.5 - To activate the data entry of upercase in the M1400 name and longname......................................................47  1.2.4.6 - To configure the automatic deconnection of client after inactivity period  .........................................................48 1.2.4.7 - To configure the number of NEs for which a warning message is displayed in NML View ............................48  1.2.4.8 - To deactivate the automatic routing of trails/bearer SDH ...................................................................................48  

    1.2.4.9 - To configure the use of Proxy for SLF-v1 and SLF-N..........................................................................................49  1.2.4.10 - To configure the use of Proxy for SLF-H .............................................................................................................49  1.2.4.11 - To configure the use of client without an alarm window....................................................................................49  1.2.4.12 - To display the ADR10000 Proxy menu  ...............................................................................................................49 1.2.4.13 - To configure the launching of the Equipment View (ADR10000) ....................................................................49  

    1.2.5 - The Application Easy Launcher under Windows   .....................................................................................50 1.2.6 - To start the Server Application with Windows ..........................................................................................51  

    1.2.6.1 - To start the Server with Easy Launcher.................................................................................................................51  1.2.6.2 - To start the server without Easy Launcher ............................................................................................................51  

    1.2.7 - To start the Client Application with Windows ............................................................................................52  1.2.7.1 - To configure the time difference between client and server ...............................................................................53  

    1.2.8 - To close the Server Application with Windows .........................................................................................53  1.2.8.1 - To close the Server with Easy Launcher ...............................................................................................................53  1.2.8.2 - To close the Server without Easy Launcher. ........................................................................................................53  

    1.2.9 - To close the Client Application   ...................................................................................................................53 1.2.10 - To start the HTTP Proxy Application with Windows ..............................................................................53  1.2.11 - To close the HTTP Proxy Application with Windows   ............................................................................54 1.2.12 - To start the Proxy Application for SLF-v1 and SLF-N ...........................................................................54  1.2.13 - To close the Proxy Application for SLF-v1 and SLF-N   .........................................................................55 

    1.2.14 - To start the Proxy Application for SLF-H under Windows ....................................................................55  1.2.15 - To close the Proxy Application for SLF-H ...............................................................................................55  1.3 - TO INSTALL THE CD FOR SOLARIS  .........................................................................................................................56 

    1.3.1 - To install the Server and Client Applications ............................................................................................56  1.3.1.1 - To install the Server Application with Solaris ........................................................................................................56  1.3.1.2 - To install the Client Application with Windows......................................................................................................56  1.3.1.3 - To install the HTTP Proxy Application with Solaris ..............................................................................................56  

    1.3.2 - To install LCT application for equipment (FMX, Sagem-Link, FSP2000, FSP3000, ADR155E) ......57  1.3.3 - Available configurations on Server IONOS-NMS .....................................................................................57  1.3.4 - Available configurations on Client IONOS-NMS ......................................................................................57  1.3.5 - To start the Server Application with Solaris ..............................................................................................57  1.3.6 - To start the Client Application with Windows ............................................................................................57  1.3.7 - To close the Server Application with Solaris .............................................................................................57  1.3.8 - To close the Client Application with Windows ..........................................................................................57  1.3.9 - To start the Proxy Applications with Solaris ..............................................................................................57  1.3.10 - To stop the Proxy Application with Solaris ..............................................................................................58  1 3 11 T t t SUN t ti ith S l i 58

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    6/205

    1.5.2.4 - Restore of backup directories copied on magnetic tape with Solaris ................................................................62  1.5.3 - To migrate a database .................................................................................................................................63  

    1.5.3.1 - Migration of a database with Windows. .................................................................................................................63  1.5.3.2 - Migration of a database with Solaris. .....................................................................................................................64  

    1.5.4 - Database Management (Split & Merge) ....................................................................................................64  1.5.4.1 - To split a IONOS-NMS database............................................................................................................................65  1.5.4.2 - Split with Solaris ........................................................................................................................................................65  1.5.4.3 - Split with Windows ....................................................................................................................................................66  1.5.4.4 - To merge two IONOS-NMS databases .................................................................................................................66  1.5.4.5 - Merge with Solaris ....................................................................................................................................................67  1.5.4.6 - Merge with Windows ................................................................................................................................................67  

    1.5.5 - Updating the traps managers table of NEs after a merge or a split ......................................................67  1.6 - EMS-ADR DATABASE MANAGEMENT (ADR 10000) .............................................................................................68  

    1.6.1 - To backup the EMS-ADR database ...........................................................................................................68  1.6.2 - To restore the EMS-ADR database in R7.2 ..............................................................................................68  1.6.3 - To restore the EMS-ADR database in R8.1 ..............................................................................................69  

    1.7 - TO SAVE THE EQUIPMENT DATABASES (EXCEPT METERING)..................................................................................71  1.8 - TO EXPORT EQUIPMENT INVENTORY IN A FILE XML.................................................................................................71  1.9 - TO EXPORT EQUIPMENT INVENTORY IN A FILE TXT.................................................................................................72  1.10 - TO EXPORT DETAILED EQUIPMENT INVENTORY IN A FILE TXT  ..............................................................................72 1.11 - ALARMS RESYNCHRONIZATION OF IONOS-NMS FOR THE SERVER NETCOOL ..............................................73  1.12 - TO RUN THE FORCE POLLING SCRIPT ..................................................................................................................73  1.13 - TO RUN THE ALIGN-NES SCRIPT...........................................................................................................................73  

    2. TOPOLOGY MANAGEMENT ....................................................................................................................................75  

    2.1 - INTRODUCTION........................................................................................................................................................75  2.2 - TOPOLOGY VIEW WINDOW .....................................................................................................................................75  2.3 - SUB-NETWORK ADMINISTRATION............................................................................................................................77  

    2.3.1 - To create a sub-network ..............................................................................................................................77  2.3.2 - To display/modify the properties of a sub-network ..................................................................................79  2.3.3 - To move a sub-network   ...............................................................................................................................81 2.3.4 - To delete a sub-network ..............................................................................................................................82  2.3.5 - To rename a sub-network ............................................................................................................................82  2.3.6 - To change the sub-network background image .......................................................................................82  2.3.7 - To delete the sub-network background image .........................................................................................82  

    2.4 - ADMINISTRATION OF NETWORK ELEMENTS (NE, VNE) .........................................................................................83  2.4.1 - To create a network element .......................................................................................................................83  2.4.2 - To copy a network element (NE, VNE) ......................................................................................................89  2.4.3 - To move a network element (NE, VNE) ....................................................................................................89  2.4.4 - To delete a network element (NE, VNE) ...................................................................................................89  2.4.5 - To rename a network element (NE, VNE) .................................................................................................90  

    2.4.6 - To display and modify the properties of a network element ...................................................................90  2.4.7 - To modify the M1400 name of a network element (NE, VNE) ...............................................................92  2.4.8 - To audit a network element (NE) ................................................................................................................95  2.4.9 - To reapplicate the general parameters in a network element (NMS to NE) ......................................104  2.4.10 - To align the capacity parameters from a network element (NE to NMS) .........................................106  2.4.11 - To perform an inventory alignment for a network element (NE) ........................................................107  2 4 12 To display and modify the configuration of an equipment 109

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    7/205

    3.1 - INTRODUCTION......................................................................................................................................................130  3.2 - NML VIEW WINDOW ..............................................................................................................................................130  

    3.2.1 - To display / filter a list of objects ...............................................................................................................132  3.2.2 - To use an element of a list as input filter .................................................................................................134  3.2.3 - List of objects in search area ....................................................................................................................134  

    4. ALARMS MANAGEMENT........................................................................................................................................135  

    4.1 - INTRODUCTION......................................................................................................................................................135  4.2 - MANAGEMENT OF CURRENT ALARMS....................................................................................................................136  

    4.2.1 - To display the current alarms ....................................................................................................................136  4.2.2 - To acknowledge a current alarm ..............................................................................................................138  4.2.3 - To unacknowledge a current alarm ..........................................................................................................138  4.2.4 - To filter current alarms by criteria .............................................................................................................138  4.2.5 - To locate a current alarm ...........................................................................................................................140  4.2.6 - To display the properties of a current alarm ...........................................................................................140  4.2.7 - To display the alarms unacknowledged cleared alarms .......................................................................141  4.2.8 - To display the new alarms .........................................................................................................................142  4.2.9 - To filter current alarms by multi-criteria ...................................................................................................143  4.2.10 - To activate the send of mails on alarms modification   .........................................................................145 4.2.11 - To activate the send of mails on critical alarm .....................................................................................146  

    5. HISTORIES MANAGEMENT  ...................................................................................................................................148 

    6. PREFERENCES MANAGEMENT ...........................................................................................................................152  

    6.1 - INTRODUCTION......................................................................................................................................................152  6.2 - PREFERENCES ......................................................................................................................................................152  

    6.2.1 - To change the IP address of the server ..................................................................................................152  6.2.2 - To change an icon image ..........................................................................................................................153  6.2.3 - To change the default properties of the Nes ...........................................................................................154  6.2.4 - To change the default properties of sounds   ...........................................................................................155 

    7. USERS MANAGEMENT ...........................................................................................................................................157  7.1 - INTRODUCTION......................................................................................................................................................157  7.2 - ADMIN VIEW WINDOW............................................................................................................................................157  

    7.2.1 - To create a profile .......................................................................................................................................159  7.2.2 - To create a group ........................................................................................................................................161  7.2.3 - To create a user ..........................................................................................................................................163  7.2.4 - To display/modify the properties of a profile ...........................................................................................164  7.2.5 - To display/modify the properties of a group ............................................................................................166  7.2.6 - To display/modify the properties of a user ..............................................................................................168  

    7.2.7 - To copy a profile ..........................................................................................................................................170  7.2.8 - To copy a group ..........................................................................................................................................171  7.2.9 - To copy a user .............................................................................................................................................172  7.2.10 - To delete a profile .....................................................................................................................................174  7.2.11 - To delete a group ......................................................................................................................................174  7.2.12 - To delete a user ........................................................................................................................................174  7 2 13 To lock a user 174

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    8/205

    8.2.11 - To Restore the database on a server ....................................................................................................183  8.2.12 - To Change a server ..................................................................................................................................183  8.2.13 - Backup 1+1 of IONOS NMS servers (Option) ......................................................................................183  

    8.2.13.1 - Introduction ............................................................................................................................................................183  

    8.2.13.2 - Procedure of backup ............................................................................................................................................184  APPENDIX - SPECIAL FUNCTIONS UPON OBJECTS  ........................................................................................187 

    APPENDIX - SNMP VIEW TABLE ..............................................................................................................................190  

    MIB II MENU ..................................................................................................................................................................190  EQUIPMENT MENU.........................................................................................................................................................195  SESSION MENU..............................................................................................................................................................198  

    APPENDIX – EXAMPLE OF SPLIT/MERGE SCENARIO.......................................................................................199  

    APPENDIX – EXAMPLE OF SNMP TRAP GENERATOR CONFIGURATION ...................................................202  

    APPENDIX – EXAMPLE OF GETTRAILLONGNAMES SCRIPT USAGE ...........................................................204  

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    9/205

    LIST OF FIGURES

    FIGURE 1.1 : GENERAL ARCHITECTURE OF IONOS-NMS.................................................................................................16  FIGURE 1.2 : IONOS-NMS SOFTWARE PLATFORM  ...........................................................................................................17 FIGURE 1.3 : WINDOW - IONOS SOLUTIONS SERVER –  DIAGNOSTIC.................................................................................18  FIGURE 1.4 : WINDOW - IONOS SOLUTIONS CLIENT –  DIAGNOSTIC  ..................................................................................20 FIGURE 1.5 : WINDOW - NMSPERFTOOL –  SCHEDULED TASK...........................................................................................22  FIGURE 1.6 : EASY LAUNCHER (1) .......................................................................................................................................50  FIGURE 1.7 : EASY LAUNCHER (2) .......................................................................................................................................50  

    FIGURE 1.8 : EASY LAUNCHER (3) .......................................................................................................................................51  FIGURE 1.9 : WINDOW - START IONOS-NMS SERVER .......................................................................................................51  FIGURE 1.10 : DOS COMMANDS WINDOW ..........................................................................................................................52  FIGURE 1.11 : WINDOW - CONNECT TO WHICH NAME SERVER .........................................................................................52  FIGURE 1.12 : LOGIN WINDOW  ...........................................................................................................................................52 FIGURE 1.13 : WINDOW –  HTTP PROXY APPLICATION .....................................................................................................54  FIGURE 1.14 : WINDOW SLF-V1 SLF-N PROXY APPLICATION  .........................................................................................55 FIGURE 1.15 : WINDOW –  SLF-H PROXY APPLICATION ....................................................................................................55  FIGURE 1.16 : FORCE BACKUP WINDOW............................................................................................................................60  

    FIGURE 1.17 : BACKUP / DATABASE WINDOW .....................................................................................................................61  FIGURE 2.1 : TOPOLOGY MAIN VIEW ..................................................................................................................................75  FIGURE 2.2 : WINDOW –  CREATE SUB-NETWORK (1).........................................................................................................77  FIGURE 2.3 : WINDOW –  CREATE SUB-NETWORK (2).........................................................................................................78  FIGURE 2.4 : WINDOW –  CREATE SUB-NETWORK (3).........................................................................................................78  FIGURE 2.5 : WINDOW –  SUB-NETWORK PROPERTIES /  GENERAL ....................................................................................79  FIGURE 2.6 : WINDOW –  SUB-NETWORK PROPERTIES /  ADDITIONAL INFORMATION .........................................................80  FIGURE 2.7 : WINDOW –  SUB-NETWORK PROPERTIES /  ALARMS  ......................................................................................81 FIGURE 2.8 : WINDOW –  OPEN ...........................................................................................................................................82  

    FIGURE 2.9 : WINDOW –  CREATE A NETWORK ELEMENT (1)..............................................................................................83  FIGURE 2.10 : WINDOW –  CREATE NE  /  SECONDARY IP ADDRESS).................................................................................84  FIGURE 2.11 : WINDOW –  CREATE A NETWORK ELEMENT (2)  ...........................................................................................84 FIGURE 2.12 : WINDOW –  CREATE A NETWORK ELEMENT (3)  ...........................................................................................85 FIGURE 2.13 : WINDOW –  CREATE A NETWORK ELEMENT (4)  ...........................................................................................86 FIGURE 2.14 : WINDOW –  CREATE A NETWORK ELEMENT (5)  ...........................................................................................87 FIGURE 2.15 : WINDOW –  CREATE A NETWORK ELEMENT (6)  ...........................................................................................88 FIGURE 2.16 : WINDOW NETWORK ELEMENT PROPERTIES ...............................................................................................90  FIGURE 2.17 : WINDOW NETWORK ELEMENT PROPERTIES /  ALARMS...............................................................................91  

    FIGURE 2.18 : WINDOW NETWORK ELEMENT PROPERTIES ...............................................................................................92  FIGURE 2.19 : WINDOW RENAME NE M1400 NAME (1) ....................................................................................................92  FIGURE 2.20 : WINDOW RENAME NE M1400 NAME (2) ....................................................................................................93  FIGURE 2.21 : WINDOW RENAME NE M1400 NAME (3) ....................................................................................................93  FIGURE 2.22 : WINDOW RENAME NE M1400 NAME (4) ....................................................................................................93  FIGURE 2.23 : WINDOW RENAME NE M1400 NAME (5) ....................................................................................................93  FIGURE 2.24 : WINDOW RENAME NE M1400 NAME (6) ....................................................................................................94

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    10/205

    FIGURE 2.41 : WINDOW GENERAL PARAMETERS REAPPLICATIONRESULTS..................................................................105  FIGURE 2.42 : WINDOW GENERAL PARAMETERS REAPPLICATIONRESULTS /DETAILS ...................................................106  FIGURE 2.43 : WINDOW AUDIT  /  CAPACITY PARAMETERS ALIGNMENT...........................................................................106  FIGURE 2.44 : WINDOW GENERAL CAPABILITY PARAMETERS ALIGNMENT RESULTS  ......................................................107 

    FIGURE 2.45 : WINDOW AUDIT  /  INVENTORY ALIGNMENT ...............................................................................................108  FIGURE 2.46 : WINDOW INVENTORY ALIGNMENT RESULTS .............................................................................................108  FIGURE 2.47 : WINDOW SAGEM-LINK EQUIPMENT VIEW  .............................................................................................110 FIGURE 2.48 : WINDOW SAGEM-LINK LIGHT EQUIPMENT VIEW.................................................................................110  FIGURE 2.49 : WINDOW SLF-A EQUIPMENT VIEW...........................................................................................................110  FIGURE 2.50 : WINDOW NETWORK ELEMENT PROPERTIES /  FMX INVENTORY ..............................................................111  FIGURE 2.51 : EXAMPLE OF SNMP VIEW WINDOW .........................................................................................................112  FIGURE 2.52 : WINDOW NETWORK ELEMENT BACKUP RESULTS ....................................................................................112  FIGURE 2.53 : WINDOW –  NETWORK ELEMENT BACKUP FAILED RESULT........................................................................113  

    FIGURE 2.54 : WINDOW –  CRITICAL FMX BACKUP MISSING ALARM IN FAULT VIEW .......................................................114  FIGURE 2.55 : WINDOW –  WARNING CONFIGURATIONCHANGED ALARM IN FAULT VIEW ..............................................114  FIGURE 2.56 : WINDOW NETWORK ELEMENT RESTORATION ..........................................................................................114  FIGURE 2.57 : WINDOW NETWORK ELEMENT RESTORATION RESULTS ..........................................................................115  FIGURE 2.58 : WINDOW SOFTWARE MANAGEMENT WINDOW ..........................................................................................116  FIGURE 2.59 : WINDOW SOFTWARE MANAGEMENT WINDOW /  INVENTORY  ....................................................................118 FIGURE 2.60 : WINDOW PERF VIEW ON SLF-V1..............................................................................................................121  FIGURE 2.61 : WINDOW PERF VIEW /  NMSPERFTOOL ON SLF-V1 .................................................................................122  FIGURE 2.62 : WINDOW PERF VIEW /  NMSPERFTOOL ON SLF-H (ETHERNET COUNTERS) ..........................................123  

    FIGURE 2.63 : DISCOVER NETWORK ELEMENTS WINDOW  ..............................................................................................126 FIGURE 2.64 : WINDOW –  DISCOVER NETWORK ELEMENTS /SEEDS...............................................................................126  FIGURE 2.65 : WINDOW –  DISCOVER NETWORK ELEMENTS /COMMUNITIES...................................................................127  FIGURE 2.66 : WINDOW –  DISCOVER NETWORK ELEMENTS /DISCOVERING ...................................................................127  FIGURE 2.67 : WINDOW –  DISCOVER NETWORK ELEMENTS /STATUS .............................................................................128  FIGURE 2.68 : WINDOW –  TOPOLOGY VIEW / TREE............................................................................................................128  FIGURE 2.69 : WINDOW –  TOPOLOGY VIEW /  SEARCH NE ..............................................................................................129  FIGURE 3.1 : NML VIEW : SEARCH AREA (1) ...................................................................................................................130  FIGURE 3.2 : NML VIEW : DETAILS AREA (2) ....................................................................................................................131  

    FIGURE 3.3 : NML VIEW /  MAIN FILTER /  TRAILS /  FILTER ...............................................................................................132  FIGURE 3.4 : NML VIEW /  MAIN FILTER /  TRAILS /  FILTER /  LIST CONFIGURATION  .........................................................133 FIGURE 4.1 : WINDOW TOPOLOGY VIEW /  FAULT VIEW ...................................................................................................136  FIGURE 4.2 : WINDOW TOPOLOGY VIEW /  FAULT VIEW /  POP-UP MENU .........................................................................137  FIGURE 4.3 : WINDOW TOPOLOGY VIEW /  FAULT VIEW /  LIST CONFIGURATION..............................................................139  FIGURE 4.4 : WINDOW ALARMS PROPERTIES /  INFORMATION..........................................................................................140  FIGURE 4.5 : WINDOW UNACKNOWLEDGED CLEARED AND NEWALARMS .......................................................................141  FIGURE 4.6 : WINDOW UNACKNOWLEDGED CLEARED AND NEWALARMS .......................................................................142  FIGURE 4.7 : WINDOW TOPOLOGY VIEW /FAULT VIEW /  LIST CONFIGURATION /  MULTI-CRITERIA FILTERING ...............144 

    FIGURE 5.1 : WINDOW LOG VIEW /  EVENT LOG ...............................................................................................................149  FIGURE 5.2 : WINDOW LOG VIEW /  FAULT LOG................................................................................................................149  FIGURE 5.3 : WINDOW LOG VIEW /  SERVER LOG.............................................................................................................150  FIGURE 5.4 : WINDOW LOG VIEW /  DATABASE LOG.........................................................................................................150  FIGURE 5.5 : WINDOW LOG VIEW /  SDH TRAILS LOG  .....................................................................................................151 FIGURE 6.1 : WINDOW PREFERENCES /  IONOS-NMS....................................................................................................152  FIGURE 6 2 : WINDOW PREFERENCES / TOPOLOGY VIEW 153

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    11/205

    FIGURE 7.15 : WINDOW ADMIN VIEW /  PROFILES /  DEFINITION .......................................................................................165  FIGURE 7.16 : WINDOW ADMIN VIEW /  PROFILES /  AUTHORIZATION...............................................................................165  FIGURE 7.17 : WINDOW ADMIN VIEW /  GROUPS  /  DEFINITION........................................................................................167  FIGURE 7.18 : WINDOW ADMIN VIEW /  GROUPS /  ADDITIONAL INFORMATION.................................................................167  

    FIGURE 7.19 : WINDOW ADMIN VIEW /  USERS /  DEFINITION............................................................................................168  FIGURE 7.20 : WINDOW ADMIN VIEW /  LDAP USERS /  DEFINITION..................................................................................168  FIGURE 7.21 : WINDOW ADMIN VIEW /  USERS /  PASSWORD...........................................................................................169  FIGURE 7.22 : WINDOW ADMIN VIEW /  USERS /  ADDITIONAL INFORMATION  ...................................................................169 FIGURE 7.23 : WINDOW PROFILE CREATION (1)...............................................................................................................170  FIGURE 7.24 : WINDOW PROFILE CREATION (2)...............................................................................................................170  FIGURE 7.25 : WINDOW PROFILE CREATION (3)...............................................................................................................171  FIGURE 7.26 : WINDOW GROUP CREATION (1) ................................................................................................................171  FIGURE 7.27 : WINDOW GROUP CREATION (2) ................................................................................................................172  

    FIGURE 7.28 : WINDOW ADMIN VIEW /  USERS /  DEFINITION............................................................................................172  FIGURE 7.29 : WINDOW USER CREATION (1) ...................................................................................................................173  FIGURE 7.30 : WINDOW USER CREATION (2) ...................................................................................................................173  FIGURE 7.31 : WINDOW USER CREATION (3) ...................................................................................................................173  FIGURE 7.32 : WINDOW ADMIN VIEW /  USERS /  DEFINITION............................................................................................175  FIGURE 7.33 : WINDOW ADMIN VIEW /  USERS /  DEFINITION............................................................................................176  FIGURE 8.1 : WINDOW IONOS FEDERATOR.......................................................................................................................177  FIGURE 8.2 : WINDOW IONOS FEDERATOR /  ALARMS ......................................................................................................178  FIGURE 8.3 : WINDOW IONOS FEDERATOR /  ALARMS /  LIST ............................................................................................179  

    FIGURE 8.4 : WINDOW IONOS FEDERAOR /  LIST CONFIGURATION...................................................................................180  FIGURE 8.5 : WINDOW IONOS FEDERATOR /  LOGIN ON CLIENT.......................................................................................181  

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    12/205

    LIST OF ABBREVIATIONS

    AU Administrative Unit

    BBE Background Block Error (Bloc erroné résiduel)

    CIR Committed Information Rate

    EML Equipment Management Layer

    EMS Equipment Management System

    LCT Local Craft Terminal

    ES Errored Second

    SES Severely Errored Second

    GUI Graphic User InterfaceMCP Management Control Panel

    MIB Management Information Base

    NE Network Element

    PDH Plesiochronous Digital Hierarchy

    PIR Peak Information Rate

    QOS Quality Of ServiceSIA Signal d’Indication d’Alarme

    SNMP Simple Network Management Protocol

    TPI Terminal Portable Intelligent

    TU Tributary Unit

    TUG Tributary Unit Group

    UAP Unavailable PeriodUAS Unavailable Second

    VC Virtual Container : VC-4, VC-3, VC-12

    VNE Virtual Network Element (not managed by NMS)

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    13/205

    TYPOGRAPHICAL CONVENTIONS

    Window or screen.Ex : Create a network element   name of window or screen displayed

    Screen access path from menu bar or pop-up menu.Ex : Topology > New > NE sequence of functions selected from menu bar to display the

    following screen

    Create a Network Element / General

    Network Element (NE), Sub-network, Tab or Function selected in explorer, in a window or in a menu.Ex : General  Tab selected in window shown above

    Text insertion or selection field.Ex : “Name“ field forming part of window shown above

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    14/205

    GLOSSARY

    Virtual network elements (VNE)

    A network managed by the network manager is generally connected to another SDH network which iseither the network of another operator or the SDH equipment of another manufacturer managed byanother manager

    The Virtual Network Elements (VNE) are used to represent the SDH equipment which is not managedby the manager and to create links between the Network Elements and the Virtual Network Elements.

    Alarm

    An alarm is a fault detected on a network element (NE) : a severity degree (major, minor or non-alarm)is associated to each alarm. This information is sent to the manager using the SNMP protocol.

    Event

    An event is an information item sent by the equipment using the SNMP protocol. Though there is noevent severity range, there are several types of events:

      Protection event when connection occurs

      Startup event when equipment is activated

      Session event when user initiates a « login » or a « logout »

      Maintenance event when a loop is created or cancelled

      Loading event when downloading occurs

      Change of attribute event (change of HTTP session)

      Performance event

    Console/Client/Server/User/”Customer”

    Console : refers to the user workstation. 

    Cli f li i f h C l

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    15/205

    1. SYSTEM INSTALLATION AND MANAGEMENT

    1.1 - GENERAL INFORMATION 

    1.1.1 - IONOS-NMS

    The IONOS-NMS system provides an efficient solution for management of a digital data transmission networkincluding:

    - SAGEMCOM SDH equipment : ADR155C, ADR155CPE, ADR155E, ADR63E1, EXT155HA, ADR2500C,ADR2500 EXTRA, ADR622, ADR10000, ADR10000HN, FOT155A, FOT155C

    - SAGEMCOM PDH equipments : FMX, Sagem-Link, Sagem-Link 2, Sagem-Link Light, SLA, SLF-v1, SLF-N, SLF-H, SLT, SLF-A

    - SAGEMCOM WDM equipments : FSP2000 and FSP3000,

    - SAGEMCOM DSLAM equipments : 4400, 4048, 4450 and 4900

    - SAGEMCOM TV Num equipment : DTX and DTX2

    - SAGEMCOM Data Concentrator : XP3000

    IONOS-NMS offers EMS functions for all the SAGEMCOM equipments

      Equipment configuration and alarm management

    Cf Installation and user guide EMS management 253 153 959-05

    IONOS-NMS offers NMS functions for the following SAGEMCOM equipments :ADR155C, ADR155CPE,ADR155E, ADR63E1, EXT155HA, ADR2500C, ADR2500 EXTRA, ADR622, ADR10000HN, ADR10000,FSP2000 and FSP3000

      Configuration and management for links, bearers and trails

      Alarm management for trails

      Management of SDH protections: SNCP, MSP MS-SPRing (for ADR2500C, ADR2500 eXtraand ADR10000HN only)

      Management of DWDM protections : SNC optique

    Cf Installation and user guide EMS/NMS management 253 153 897-05

    IONOS-NMS offers EMS functions for all the SAGEMCOM Data Concentrators

    Cf Installation and user guide Metering 253 153 941 05

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    16/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.1.2 - Architecture

    1.1.2.1 - General architecture

    The general architecture is built on a client-server architecture: the various clients can be installed on severalphysical machines connected to the same server.The interface between the network element (NE equipment) and IONOS-NMS uses the SNMP V1 or SNMP Nprotocol to send the alarm messages and to configure the end-to-end trails (« provisioning »).This interface also uses the HTTP protocol to configure the equipment (NE integrating an on-card HTTPserver).

    The management data are stored on the server.

    CLIENT Plateform Windows

    SGBD

    SERVER Plateform Windows or Solaris

    run

    RMI, TCP

    SNMP TFTP HTTP

    IONOS-NMSSERVER

    TopologyAlarmsSécurity

    Performances

    IONOS-NMSCLIENT

    Generic functions

    InternetExplorer

    Specific functions toequipment

    HTTPPROXY

    HTTP

    TFTP CLIENT

    TFTP SERVER

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    17/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.1.2.2 - Software architecture

    IONOS-NMS is built on software modules implementing independent functional blocks developed in JAVA:each block only processes a function subset of the complete software.

    IONOS-NMS is based on the LUMOS software environment which supplies:  an SNMP interface.

      base services on which the main functions of the network elements manager are based(alarms, logs, etc.)

      a Client application (MCP) based on use of Java Beans and providing the graphic interfaceelements (topology, etc.)

    The main application, developed by SAGEMCOM, integrates the network level functions.

    The access to HTML pages for equipment of type ADR is done via a HTTP Proxy installed on the IONOS-NMS Server.

    IONOS NMS comprises the following modules:

      The Client Application , which contains the functions for data presentation to the operator(commonly called the client terminal).

      The Server Application  which implements the core functions.

    The IONOS-NMS platform contains a Network element manager and a Network manager.

    Figure 1.2 : IONOS-NMS software platform

    1.1.3 - Workstations

    The Client Applications are run on a PC whereas the Server Application is run either on a PC or on a UNIXplatform. For small networks, the Client Application can be run on the same PC platform as the server, instand-alone mode.The hardware platform thus remains flexible, open-ended and modular in terms of hard disk, RAM and

    Network

    Manager 

    Network

    Element

    Manager

    Faults on NE NEconfiguration

    Faults oncircuits

    Security

    Configurationof circuits

    NEperformances

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    18/205

    SYSTEM INSTALLATION AND MANAGEMENT

      If the action is long (example: activation/deactivation of trail, audit, etc.), a waiting window isdisplayed. When the action is completed, a window indicates the result or an error message.

    1.2 - INSTALLING THE CD WITH WINDOWS

    The IONOS-NMS software is supplied on a CD with a manual.Two installations exist :

      The installation of a server PC (with client)

      The installation of a client PC

    1.2.1 - To install the Server + Client Applications

    The operating system and the database Oracle have been installed beforehand on the PC where the serverapplication is installed.

    1.2.1.1 - To install the Server Application (with Client)

    Caution: The installation of the Server Application must be carried out by a personnel qualifiedSagemcom.

      Insert CD on the PC used as server. A menu appears automatically. If it does not appear, double-to

    click on the file "menu.vbs".

      Select the language ("English").

      Click on "Installation on a windows PC".

      Click on "Ionos-NMS 5.5 installation".

      Click on "Full (server with client)"

      Follow the installation instructions: choose a directory (Ionos-NMS by default).

      Click on [Quit].

    A screen of diagnosis is displayed and gives the results of installation.

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    19/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Notes: It is possible to modify:-  the repertory used by default for backup of the database

    (c:\temp\oracle.backup) (see § 1.2.3.3 - )

    -  the repertory used by default for backup of the databases of equipment (Ionos-NMS\backup\equipment) (see §1.2.3.3 - )

    To check that:-  IP address of the server seen by the equipment corresponds to IP address of

    the PC on which the server is installed (see § 1.2.3.2 - )

    To use a HTTP Proxy, see § 1.2.4.3 - .

      Click on [Save configuration].

      Click on [Quit] to quit the installation.

    At the end of the installation procedure, short cuts are available in menu Start  :

      Ionos-NMS 5.5 Client : Client Application (1).

      Ionos-NMS 5.5 Server : Server Application.

      TFTP : downloading software.

      Ionos-NMS 5.5 (Easy Launcher) : used for Server starting.

      Ionos-NMS 5.5 (Federator) : Federator Application (see § 1.4 -)

      Copy the short cuts on the computer desktop (Drag and Drop of short cut of menu Start with the keyCTRL pressed)

    Note: (1) The Client application is also installed on the same PC. It will be used only for the stand-alone configuration (Server + 1 Client on the same computer).

    Modification of license file

      In the directory chosen for installation (Ionos-NMS by default), select the Config. folder.

      Copy the file LICENSE.DAT, provided with application.

    Note: With a license "CORE", only the functions EMS are available.

    Modification of database configuration file (for a no standard configuration)

      In the directory chosen for installation (Ionos-NMS by default), select the Config folder.

    In the folder open the oracle ext assembly xml file

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    20/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.2.1.2 - To install the Client Application

      Insert CD on the PC used as Client. A menu appears automatically. If it does not appear, double-toclick on the file "menu.vbs".

      Select the language ("English").

      Click on "Installation on a windows PC".

      Click on "Ionos-NMS 5.5 installation".

      Click on "Client".

      Follow the installation instructions: choose a directory (Ionos-NMS by default).

      Click on [Quit].

    A screen of diagnosis is displayed and gives the results of installation. The two parameters concerning theproxy are not used (see § 1.2.4.2 - ).

    Figure 1.4 : Window - Ionos Solutions Client – Diagnostic

    Note: To use a HTTP Proxy, see § 1.2.4.3 -

      Click on [Save configuration]

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    21/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.2.1.3 - To install the Proxy Application

      Insert CD on the PC used as Server. A menu appears automatically. If it does not appear, double-toclick on the file "menu.vbs".

      Select the language ("English")

      Click on "Installation of a server PC (with client)"

      Click on "Ionos HTTP Proxy 3.2 installation "

      Follow the installation instructions: choose a directory (Ionos HTTP Proxy by default).

      Click on "HTTP" to install an HTTP proxy only.

      Click on "SLF-v1 F-N" to install a proxy for equipment of type SLF-v1 and SLF-N.

      Click on "SLF-H" to install a proxy for equipment of type SLF-H

      Click on "Full" to install the two proxy : HTTP proxy and proxy for equipment of type SLF-v1 SLF-N,and SLF-H.

      Click on [Quit].

      A screen of diagnosis is displayed and gives the results of installation. (see § 1.2.1.1 - )

      Click on [Quit] to quit the installation.

    At the end of the installation procedure, short cut are available in menu Start  :

      Ionos HTTP Proxy 3.2 : HTTP Proxy Application.

      Start Ionos Proxy 3.2 (SLF-H) : to launch the Proxy Application for equipment of type SLF-H

      Start Ionos Proxy 3.2 (SLF-v1 SLF-N) : to launch the Proxy Application for equipment oftype SLF-v1 and SLF-N.

      Stop Ionos Proxy 3.2 (SLF-v1 SLF-N) : to stop the Proxy Applicationfor equipment of type

    SLF-v1 and SLF-N.  Copy the short cut on the computer desktop (Drag and Drop of short cut of menu Start with the key

    CTRL pressed).

    Caution: In the case of the use of HTTP Proxy, to guarantee the access security to the equipment, itis possible to add IP address of the server with a habilitation "Supervisor" in each NE of typeADR155C, ADR155CPE, ADR2500C, ADR2500 EXTRA, ADR622 or ADR63E1 which will bemanaged by IONOS-NMS. For that to use HTTP browser : Menu "Equipment/Management" – toadd IP address of the server in the table "List Managers" while clicking on "Supervisor". To

    validate the modification with "Apply".

    The HTTP Proxy is available with :

    -  ADR155C P3.5 and > P3.5-  ADR2500C P2.4 and > P2.4

    ADR63E1 P2 0 and > P2 0

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    22/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.2.1.4 - To install the NMSperftool Application

    The NMSPerftool allows to collect the performance counters on equipment of type Sagem-Link , SLF-v1, SLF-N

    and SLF-H.

      Insert CD on the PC used as Server.

      Open the Folder "Install"

      Double-Click on "nmsperftool.exe"

      Confirm the installation directory.

      Wait several minutes: some windows are displayed, then closed.

      A scheduled task is automatically created and the next window is displayed, in case of password.

      Give the password.

    Figure 1.5 : Window - NMSperftool – Scheduled task

      The NMSperftool Application is installed.

    1.2.2 - To install LCT application for equipment (FMX, Sagem-Link, FSP2000,

    FSP3000, ADR155E)

    The LCT application for FMX, Sagem-Link 2, SLF-v1, SLA, SLF-N, SLF-H, FSP2000, FSP3000, ADR155E isused by the Client IONOS-NMS.

    Notes: The LCT applications for equipment FOTC and Sagem-Link light are embedded. No particularinstallation is needed

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    23/205

    SYSTEM INSTALLATION AND MANAGEMENT

      Click on "TPI-FMX / FSP2000 / FSP3000 / Sagem-Link 2 / SLF-v1 / SLF-N / SLF-H / SLA installation "

      Follow the installation instructions

      Don't reboot immediately the PC.

    A window of diagnosis gives the results of installation.

      Click on [Save configuration].

      Click on [Quit] to quit the installation.

      Reboot the PC.

    1.2.2.2 - To install LCT application for equipment ADR155E

      Insert CD on the PC used as Server.

      Open the folder "Install/TPI/ADR155E".

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    24/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Note: The LCT of the 155E is using ftp server. Refer to § 1.2.5 - “ The Application Easy Launcherunder Windows ” to know how to launch ftp server under Windows

    1.2.3 - Available configurations on Server IONOS-NMS

    1.2.3.1 - To configure TFTP server

      Launch the TFTP server.

      In the Settings, enter:Timeout = 20 s ;Base Directory = C:\Program Files\Ionos-NMS\tftproot (if Ionos-NMS chosen by default)

    Note: This configuration is made automatically after the installation of the Server on PC.It is imperative on the Unix server.

    1.2.3.2 - To configure IP address of the server seen by the equipment

      In the directory chosen for the installation (by default Ionos-NMS), Select the Config  folder.

      In the folder, open the file Server.xml

      Update the field "LocalServerAdress" so that it corresponds to IP address of the PC server seen bythe equipment.

    This modification will be effective only after launching of Server IONOS-NMS.

    Note: This configuration is made automatically after the installation of the Server on PC.It is imperative on the Unix server.

    1.2.3.3 - To configure the backup directories

    Backup directory for the Server database

    The backup files (backup of database Oracle) will be copied in the directory given in the File.xml  file. Thedirectory by default can be modified :

      In the directory chosen for installation (Ionos-NMS by default), select the Config folder.

      In the folder, open the File.xml file

      In this file, update the field "oracle-backup-dat" path.

    Note:This modifcation will be effective only after launching of Server IONOS-NMS.The database back-up files are saved in directory "c:/temp/oracle.backup/AAAA/AAAA-MM/JJ" byd f lt

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    25/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Caution: If the directory of the NE database has been modified, it is necessary to update theequipmentbackup.xml   file to be able to display the NE database list available and to restore it. The

    directory by default can be modified :

      In the directory chosen for installation (Ionos-NMS by default), select the Config Folder.

      In the folder, open the equipmentbackup.xml file

      In this file, update the field "backup repository" so as to match to the specified directory that isgenerally the same as the previously modified in the File.xml file.

    1.2.3.4 - To configure the HTTP Proxy Function

      In the directory chosen for installation of Proxy (Ionos HTTP Proxy), select the Config. folder.

      In the folder, open the HttpProxy.cfg file  

      After the tag [SERVER], insert a line which gives IP address of the server (x.x.x.x)

      After the tag [Allow], remove the line "x.x.x.x:x.x.x.x=OBSERVER".

    Note: This configuration will be effective only after launching of Proxy Application.

    Caution: the Proxy HTTP rejects all the addresses which are not true IP adress. (for example :sagem.com will be rejected and an error message will be logged.)

    1.2.3.5 - To configure the function Traps Forward

    The function Traps Forward is installed on the Server IONOS-NMS.By default, this function is not activated. The file "forward.xml " must be configured to activate the function.

      In the directory chosen for installation (Ionos-NMS by default), select the Config/Forward folder.

      In the folder, open the forward.xml file

      In this file, update the parameters of manager which will receive the traps : the IP address, the NEtype ((default, ADR2500C, ADR2500EXTRA, ADR10000HN, ADR155C, ADR155CPE,

    ADR155C_P2_6, ADR63E1, ADR622, ADR155E, EXT155HAPHYSICAL, FOT155C, FOT155A,FHLINK, FHLINKLIGHT, FHLINK_2, FHLINK-F, FHLINK-A, FHLINK_HC, FSP2000, FSP3000 FMX,TRIPACK4048, TRIPACK4400, TRIPACK4450, TRIPACK4900) and the trap type (default, LogTrap,ThresholdTrap, EquipstatusTrap) for the traps filtering.

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    26/205

    SYSTEM INSTALLATION AND MANAGEMENT

      In the repertory chosen for the installation (by default Ionos-NMS), Select the Config/Perf folder.

      In this folder, Open the Config.xml file.

      Update the following parameters:

    - the deadline between two collections for the counters 15mn - > by default 180min- the deadline between two collections for the counters 24h - > by default 1320 min- the deadline between two collections for the periods of unavailabilities associated with thecollection of the counters 15mn - > by default 600min- the deadline between two collections for the periods of unavailabilities associated with thecollection of the counters 24h - > by default 1320min- the deadline between two attempts in the event of failure with the first reading - > 15min- the maximum number of points collected on 15min - > by defect 15000- the maximum number of points collected on 24h - > by defect 18000

    - the maximum number of the log for the points of collection 15mn - > by defect 10000- the maximum number of remaining lines after automatic export for the log associated with thepoints with collection 15mn - > by defect 4000- the maximum number of the log for the points of collection 24h - > by defect 10000- the maximum number of remaining lines after automatic export for the log associated with thepoints with collection 24h - > by defect 4000- the maximum number of the log for the periods of unavailability - > per defect 10000- the maximum number of remaining lines after automatic export for the log associated with theperiods with unavailability - > by defect 4000

    "R t P i d" t "j l I t " l "15"/

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    27/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Caution: The taking into account of the file modification will be effective only after launching of ServerIONOS-NMS.

    1.2.3.7 - To authorize the data entry of the accents and the special characters in the"Name" of the equipment

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config  folder.

      In this folder, open the file server-advanced.xml

      Replace the line:

    by

    Note: By default, the data entry of the accents and characters special in the "Name" of theequipment are not authorized.If the data entry of the accents and the special characters is authorized, the "Name" is not updated inthe equipment and control on this parameter (General tab) is not made in the Audit of NE(see § 2.4.8 -).

    Caution: The taking into account of the file modification will be effective only after launching of ServerIONOS-NMS.

    1.2.3.8 - To inhibit control on the name of cross-connections in the audit of the equipment

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config  folder.

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    28/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.2.3.9 - To configure the time interval between IONOS-NMS and equipment

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, open the file lfserver_ext_parameters.xml

      Modify the line (by default 60 seconds) :

    Note: When IONOS-NMS starts, The time set is done for all the NEs.Then, the time set of a NE is done if the time interval between the date and time of NE and the dateand time of IONOS exceeds the defined value.

    Caution: The taking into account of the file modification will be effective only after launching of Server

    IONOS-NMS.

    1.2.3.10 - To configure the performance parameters used by equipment

    The parameters used by equipment for performance collect ( available for ADR155 ≥ P4.1 rev AF andADR2500 EXTRA ≥ P2.1) can be modify in a file xml.

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, open the file server.xml

      Modify eventually the the following lines :

    The equipment will send threshold performance trap if it is set to "true"

    Make it possible to synchronize the performances counter on NE time modulo 15 minutes 

    Note: After the modification of this file and restart of server, launch an audit on each NE of typeADR155 ≥ P4.1 rev AF or ADR2500 EXTRA ≥ P2.1 and realign the general parameters.

    Caution: The taking into account of the file modification will be effective only after launching of ServerIONOS-NMS.

    1.2.3.11 - To configure the IONOS-NMS server name

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.  In this folder, open the file server.xml

      Modify the the following line :

    Note If l i gi f th NMSN m ( l b d f lt) th m f IONOS NMS ill b

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    29/205

    SYSTEM INSTALLATION AND MANAGEMENT

    [email protected]

      Give the address of destination (for example [email protected])

    [email protected]

    Repeat several times this sequence (one sequence by address of destination)

    It is possible to choose the format of the mail : “short” or “complete”With the “short” format, you get only a summary of all alarms

      Give if you want a subject

    NMSAlarms

    If this item is present, you will get this text in the header of your message in your mail box. If

    this item is not present, you will get a text with the severity of the alarm in the header of your

    message in your mail box.

      Give the address and the port of mail server

    10.142.3.103

    25

      The taking into account of the file modification will be effective only after launching of Server IONOS-NMS..

    Caution: It's not possible to activate "critical alarm sending mail" and "report sending mail"at the same time.

    1.2.3.13 - To configure the timers used for the send of mail

    The timers are used for the send of mail (see § 4.2.10 -). A mail is sended after X minutes for an alarm change( raised of alarm indeterminate/ warning/ minor/ major/ critical/ inaccessible, cleared, acknowledged,unacknowledged)

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    30/205

    SYSTEM INSTALLATION AND MANAGEMENT

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config/mail folder.

      In this folder, open the file criticAlarmConfig.xmlTo enable critical alarm mail for “system” alarm, change: 

    false

    by

    true

      Save and close the file criticAlarmConfig.xml

      The taking into account of the file modification will be effective only after launching of Server IONOS-NMS.

    Caution: It's not possible to activate "critical alarm sending mail" and "report sending mail"at the same time.

    1.2.3.15 - To configure the send of mail on a “system” alarm

    This procedure is used to configure the send of mail on critical alarm appartion (see § 4.2.11 -To activate the

    send of mails on critical alarm).First step : do the described actions of § 1.2.3.12 - To configure the send of mail on alarm changeSecond step :

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config/mail folder.

      In this folder, open the file criticAlarmConfig.xml To enable critical alarm mail for “system” alarm, change: 

    false

    by

    true

      Save and close the file criticAlarmConfig.xml 

      The taking into account of the file modification will be effective only after launching of Server IONOS-

    NMS.

    Caution: It's not possible to activate "critical alarm sending mail" and "report sending mail"at the same time.

    1 2 3 16 - To configure the send of mail on a specific event type

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    31/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Caution The event type name in criticAlarmConfig.xml must be strickly identical to the one seen in thecurrent alarm window (or in the fault log)

      Save and close the file criticAlarmConfig.xml

      The taking into account of the file modification will be effective only after launching of Server IONOS-NMS.

    Caution: It's not possible to activate "critical alarm sending mail" and "report sending mail"at the same time.

    1.2.3.17 - To send a mail in relation to one sub-network, NE type and NE name

    This procedure is used to configure the send of mail (in short mail format only) on critical alarm in relation to

    one sub-network (recursively), NE type and NE name.

    First step: do the described actions of § 1.2.3.12 - To configure the send of mail on alarm change

    Second step:

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config/mail folder.

      In this folder, open the file emailParameters.xml

    To enable the critical alarm mails sending for a “sub-network”, a “NE type” or a “NE name”, add or modify:

    [email protected]

    [email protected]

    [email protected]

    In this example, a mail will be sent on critical alarm to the [email protected]  receiver for all NetworkElement type ‘SLF-H’ belonging to the ‘Region Paris’ sub-network (and each sub-network included into thissub-network).Also, a mail will be sent on critical alarm to the [email protected]  receiver for all Network Element type‘SLF-N’

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    32/205

    SYSTEM INSTALLATION AND MANAGEMENT

    Caution (2): The taking into account of the file modification will be effective only after launching of ServerIONOS-NMS.

    Note: If a Network Element is moved from one sub-network to another, it is not mandatory to restart theIONOS-NMS server in order to get the mail to be send to the right receiver.

    1.2.3.18 - To configure the format of the sent mail

    This procedure is used to configure the format of the sent mail (the length of the message) in short mode oncritical alarm. (see § 4.2.11 - To activate the send of mails on critical alarm)

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config/mail folder.

      In this folder, open the file criticAlarmConfig.xml

      Modify if necessary these labels.

    Equipment: $EQUIPEMENT - Location: $LOCATION - Event type: $EVENT_TYPE - Begindate: $BEGIN_DATE - End date: $END_DATE (by default)

    You can modify or remove the labels. (e.g. Equipment to Eqpt, or delete the word ‘Equipment’)You can remove the label and its variableIf the variable exits, don’t modify its value (e.g. $EVENT is not correct, must be $EVENT_TYPE)

      Save and close the file criticAlarmConfig.xml

    Example: Eqpt: $EQUIPEMENT - $LOCATION - Evt: $EVENT_TYPE - Begin date: $BEGIN_DATE

    Caution: The taking into account of the file modification will be effective only after launching of Server IONOS-

    NMS.1.2.3.19 - To configure a timer for the send of mails

    This timer is used for the send of mail on critical alarm (see § 1.2.3.12, refer to the main document: Ionos-NMS Installation and User Guide N 253 153 959-04 or 253 153 962-04 ).A mail is sent after X seconds for an alarm change, if during this length of time a clear of this alarm was sent,the sending of e-mail is cancelled

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config/mail folder.

      In this folder, open the file criticAlarmConfig.xml  Modify if necessary the value of this timer (in seconds), 0 is the value by default.

    30 

    Caution: The taking into account of the file modification will be effective only after launching of Server IONOS-

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    33/205

    SYSTEM INSTALLATION AND MANAGEMENT

    1.2.3.21 - To allow the duplication of IP address

    This procedure is used to allow the duplication of IP address.

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, open the file server-advanced.xml

      Modify if necessary the following line :

    by :

    Caution: The taking into account of the file modification will be effective only after launching of ServerIONOS-NMS.The duplication of IP address is forbidden by defaultIn case of duplication, the following alarm is generated for each equipment: “Duplicate address IP”

    1.2.3.22 - To configure the duration of the inactivity period and the number of attemptsauthorised before locking a user

    By default, the lock of user after a period of inactivity is not activated.

    By default, the lock of user is performed after 5 wrong attempts

      In the repertory chosen for the installation (by default IONOS-NMS), select the Config folder.

      In this folder, open the file lfserver_ext_advanced.xml

      Replace the lines:

    By:

    Notes: - "MaxUserInactivityPeriod" stands for the number of full days of inactivity before a user isbeing locked.

    - "maxLoginAttempts" stands for the number of attempts authorised before a user is being locked.

    User with admin profile and default users can't be locked

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    34/205

      Save and open the file lfserver_ext_parameters.xml

      Modify the following lines :

    - ->

    by :

      Once the TMF814 northbound interface has been set up, two external applications are required tolaunch the Ionos NMS Server:

    - Corba name server- Corba notification service

    Caution: Once the TMF814 northbound interface has been set up, it will be no longer possible to launchthe NMS Server if Name server and Notifications server have not been launched will previously.

      In the repertory chosen for the installation (by default Ionos-NMS), select the Bin folder.

      In this folder, execute the following scripts:- start_TransientNameServer.bat (PC) or ./start_TransientNameServer.sh (solaris) (starts the

    name server)- start_NotificationService.bat (PC) or ./start_NotificationService.sh (solaris ) (starts thenotification service)

      IONOS-NMS server can be restarted.

    Note: If you want to step back, you just have to replace the two modified files in the config  directory bytheir backup ones.

    1.2.3.24 - To configure the scheduled task for Standby trail

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    35/205

    PPI-LOS alarms will not be inverted

    PPI-AIS alarms will be inverted

    PPI-AIS alarms will not be inverted

      Adjust the variable StandbyLimitDelay which unit is hour (default value is 720 equals 30 days)

    give the delay for an alarm to be present before to be inverted

      Adjust the variable StandbyTaskTime for the starting time of the scheduled task

      If you don’t want this task to be run, then you should configure the server_advanced.xml file according

    :

      Restart the IONOS-NMS server

    Note :  If you want log informations about this function in the server.log file or for manual actions aboutStandby trail from the NML View, modify

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.  In this folder, open the file ems_trace.properties  

      Uncomment line “log4j.category.com.sagem.ionos.nms.server.fault.priv.ext.standby=DEBUG” to getdebug informations on the Standby trail activities. The debug infos are saved in file Ionos-NMS\log\app\server.log

      Idem for :”log4j.category.com.sagem.ionos.nms.server.nml.priv.sec.SecNmlServiceImpl=DEBUG” and“log4j.category.com.sagem.ionos.nms.server.nml.priv.impl.NmlServiceLocal=DEBUG” about manualactivation

      Nota: this feature is designed for debug purposes only.

      Restart the IONOS-NMS server

    1.2.3.25 - To configure the Ldap connection

    This procedure is used to activate the LDAP connection:

      In the repertory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, save and open the file server.xml

      Modify the following lines :

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    36/205

      Restart the IONOS-NMS server

    1.2.3.26 - To configure SSH protocol

    This procedure is used to configure SSH server to replace FTP for BDD transferts with Backup 1+1 ofIONOS-NMS servers and TFTP for equipment software upgrade ( for transfert between IONOS-NMS Clientand IONOS-NMS server)

      In the directory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, open the file server-advanced.xml 

      Modify the following line

      is replaced by :

      Save and close the file server-advanced.xml

    On UNIX server :

    In the directory chosen for installation (Ionos-NMS by default), select the bin folder.

      Execute sftp_Install.sh (in order to create two users : "download" and "backup") 

      PassWord for users "download" and "backup" is "$agem001" 

      The default values can be changed (users and password)

      The last input is the path for the directory chosen for the installation (by default /tools/Ionos-NMS)

    On Windows server :

    In the directory chosen for installation (Ionos-NMS by default), select the bin. folder.This command file installs the CopSSH application and sets CopSSH installation folder and IONOS-NMS.It creates two users : "download" and "backup".

      Execute install_sftp.cmd (in order to create two users : "download" and "backup" 

      PassWord for users "download" and "backup" is "$agem001" The default values can be changed (users and password)

      Add environnement variable $CoppSHHInstall-Directoriy\bin in the system environnement variable :

    PATH

    SYSTEM INSTALLATION AND MANAGEMENT

  • 8/17/2019 Ionos Nms p5 Ems User Guide 253153962-05

    37/205

    The CopSSH server is launched as a windows' service.

    Note : If the default values of SFTP username and SFTP password of Software Upgrade are changed,they must be changed in the server-advanced.xml file.

      In the directory chosen for the installation (by default Ionos-NMS), select the Config folder.

      In this folder, open the file server-advanced.xml 

      open the file the server-advanced.xml file

      Modify the following line

    Note : If the default