3
Desco Asia Phone: +81 43-309-4470 I Fax: +81 43-332-8741 E-mail: [email protected] Web: DescoAsia.com IONIZER SELECTION CHART BENCHTOP IONIZERS BEST PERFORMANCE BEST PERFORMANCE Product Series Benchtop Blower High Output Benchtop Ionizer Benchtop Zero Volt Ionizer 961JH - Ionized Air Blower 9100-JP - Benchtop Air Ionizer Fan Count 1 1 1 1 1 Maximum Airflow 117 CFM 100 CFM 100 CFM 117 CFM 117 CFM Balance Offset Voltage ±5V ±3V ±3V ±5V ±5V Discharge Time <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 Seconds @ 30.5 cm Ion Emission AC Steady-state DC Steady-state DC AC Steady-state DC Special Feature High airflow Active balance Stainless steel enclosure High airflow Variable Fan Speeds Dimensions 22.9 H x 27.9 L x 17.8 D cm 24.1 H x 15.2 W x 7.9 D cm 24.1 H x 15.2 W x 7.9 D cm 15.3 H x 16 L x 6.3 D cm 19.8 H x 18.5 W x 10 D cm Weight 5.9 kg 2.04 kg 2.04 kg 1.3 kg 1.5 kg Certifications Intertek, CE* CE* CE* UL -- Country of Origin United States of America United States of America United States of America Japan China

IONIZER SELECTION CHART - Desco Asia

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IONIZER SELECTION CHART - Desco Asia

Desco AsiaPhone: +81 43-309-4470 I Fax: +81 43-332-8741

E-mail: [email protected]: DescoAsia.com

IONIZER SELECTION CHART

BENCHTOP IONIZERS

BEST PERFORMANCEBEST PERFORMANCE

Product Series Benchtop Blower High Output Benchtop Ionizer Benchtop Zero Volt Ionizer 961JH - Ionized Air Blower 9100-JP - Benchtop Air Ionizer

Fan Count 1 1 1 1 1

Maximum Airflow 117 CFM 100 CFM 100 CFM 117 CFM 117 CFM

Balance Offset Voltage ±5V ±3V ±3V ±5V ±5V

Discharge Time <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 seconds @ 30.5 cm <2 Seconds @ 30.5 cm

Ion Emission AC Steady-state DC Steady-state DC AC Steady-state DC

Special Feature High airflow Active balance Stainless steel enclosure High airflow Variable Fan Speeds

Dimensions 22.9 H x 27.9 L x 17.8 D cm 24.1 H x 15.2 W x 7.9 D cm 24.1 H x 15.2 W x 7.9 D cm 15.3 H x 16 L x 6.3 D cm 19.8 H x 18.5 W x 10 D cm

Weight 5.9 kg 2.04 kg 2.04 kg 1.3 kg 1.5 kg

Certifications Intertek, CE* CE* CE* UL --

Country of Origin United States of America United States of America United States of America Japan China

Page 2: IONIZER SELECTION CHART - Desco Asia

Desco AsiaPhone: +81 43-309-4470 I Fax: +81 43-332-8741

E-mail: [email protected]: DescoAsia.com

IONIZER SELECTION CHART

Product Series 973 - Ionized Air Blower 975 - Ionized Air Blower Mini Zero Volt Ionizer

Fan Count 1 1 1

Maximum Airflow 100 CFM 100 CFM 51 CFM

Balance Offset Voltage ±5V ±5V ±5V

Discharge Time <2.5 seconds @ 30 cm <1 seconds @ 30 cm <3 seconds @ 30.5 cm

Ion Emission Steady-state DC Steady-state DC Steady-state DC

Special Feature Relay and alarm output Relay and alarm output Compact size

Dimensions 18 H x 18 W x 5 D cm 17 H x 20 W x 7.2 D cm 13.5 H x 8.9 W x 4.3 D cm

Weight 2.04 kg 1.3 kg 0.5 kg

Certifications -- UL CE*

Country of Origin Japan Japan United States of America

IN-TOOL/BENCHTOP IONIZERSProduct Series Chargebuster® Ion Gun Ion Python

(Hose/Foot Switch)Ion Python

(Controller w/ Hand Gun/Hose)

Maximum Airflow 2.3 CFM @ 30 psi 3.5 CFM

Maximum Input Pressure 65 psi 100 psi

Balance Offset Voltage ±30V ±20V

Discharge Time <1 second @ 15.24 cm <2 seconds @ 15.24 cm

Ion Emission Steady-state DC AC Ionizer

Special Feature Ergonomic gun design High air pressure

Gun Dimensions 20.3 L x 7.6 W x 2.5 D cm 21.6 L x 4.6 W x 2.5 D cm

Console Dimensions 21.6 L x 7.6 W x 4.1 D cm 13 L x 16.3 W x 18 D cm

Gun + Hose Weight 0.4 kg 0.5 kg

Console Weight 0.3 kg 2.1 kg

Certifications UL, C-UL, CE* Intertek, CE*

Country of Origin China United States of America

COMPRESSED AIR IONIZERS

Page 3: IONIZER SELECTION CHART - Desco Asia

Desco AsiaPhone: +81 43-309-4470 I Fax: +81 43-332-8741

E-mail: [email protected]: DescoAsia.com

Desco AsiaPhone: +81 43-309-4470 I Fax: +81 43-332-8741

E-mail: [email protected]: DescoAsia.com

IONIZER SELECTION CHART

The ESD Association’s ANSI/ESD S20.20 requires insulators/isolated conductors that charge to:

• 125 volts or more be kept 1 inch or more away from ESD sensitive items.• 1000 volts or more be kept 12 inches or more away from ESD sensitive items.

There are 3 options available for handling insulators/isolated conductors in an EPA:

1. Move the insulators/isolated conductors beyond the 1 inch and 12 inch requirements from ANSI/ESD S20.20 2014.2. Replace the non-ESD version of insulators/isolated conductors with an ESD protective version of insulators/isolated conductors.3. Use air ionization to neutralize charges on insulators/isolated conductors.

*NOTE: CE mark only applicable to 220 VAC units.

OVERHEAD IONIZERSProduct Series Chargebuster® Overhead Ionizer Overhead Zero Volt Ionizer 9300-NO - Overhead Air Ionizer,

Fan Count 2 3 2 3 3

Maximum Airflow 200 CFM 300 CFM 200 CFM 300 CFM 270 CFM

Balance Offset Voltage ±10V ±10V ±3V ±3V ±15V

Discharge Time <3 seconds @ 45.7 cm <3 seconds @ 45.7 cm <3 seconds @ 45.7 cm <3 seconds @ 45.7 cm <3.5 seconds @ 45 cm

Ion Emission Steady-state DC Steady-state DC Steady-state DC Steady-state DC Steady-state DC

Special Feature Active balance Active balance Superior balance Superior balance Variable Fan Speeds

Dimensions 9.9 H x 16.8 W x 56.6 D cm 9.9 H x 16.8 W x 94.7 D cm 9.9 H x 16.8 W x 69.3 D cm 9.9 H x 16.8 W x 107.4 D cm 12 H x 108 W x 17.2 D cm

Weight 3.2 kg 4.5 kg 3.2 kg 4.5 kg 4.8 kg

Certifications CE* CE* CE* CE* --

Country of Origin United States of America United States of America United States of America United States of America China

BEST PERFORMANCE BEST PERFORMANCE