21
bbbbb 1. Introduction to ET Enterprises Ltd 2. Brief History 3. Product Range 4. Main Applications 5. Recent Developments 6. Current and Past projects 7. Summary of Capability VLVnT08 – Toulon April 2008

Introduction to ET Enterprises Ltd Brief History Product Range Main Applications

Embed Size (px)

DESCRIPTION

Introduction to ET Enterprises Ltd Brief History Product Range Main Applications Recent Developments Current and Past projects Summary of Capability. VLVnT08 – Toulon April 2008. Introduction to ET Enterprises Ltd. ET Enterprises Limited Bury street Ruislip HA4 7TA United Kingdom - PowerPoint PPT Presentation

Citation preview

bbbbb

1. Introduction to ET Enterprises Ltd

2. Brief History

3. Product Range

4. Main Applications

5. Recent Developments

6. Current and Past projects

7. Summary of Capability

VLVnT08 – Toulon April 2008

bbbbb

ET Enterprises LimitedBury streetRuislipHA4 7TAUnited Kingdom

phone:   +44 (0)1895 630773fax:   +44 (0)1895 631774

web:  http://www.et-enterprises.com

e-mail:  [email protected]

Introduction to ET Enterprises Ltd

VLVnT08 – Toulon April 2008

bbbbb

ET Enterprises Limited is a newly formed company which has taken over the photomultiplier and accessories business of Electron Tubes Limited and will continue to manufacture, supply and develop the Electron Tubes brand product range.

Introduction to ET Enterprises Ltd

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Ludlum Instruments Inc. Sweetwater, Texas

ADIT PmtsSweetwater

ET Enterprises Ruislip UK

ELJENSweetwater

Introduction to ET Enterprises Ltd

VLVnT08 – Toulon April 2008

bbbbb

• ET Enterprises will benefit from the additional volume production facilities of ADIT.

• The more specialised pmts will continue to be made in the UK at the same location as our Development facility.

Introduction to ET Enterprises Ltd

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Introduction to ET Enterprises Ltd

• Combined resources of the two operations will enable the new company to extend its penetration into higher volume, lower cost markets

• Benefit from ET Enterprises’ knowledge and experience in many different photomultiplier applications worldwide.

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Brief History

As EMI Electron Tubes Ltd: 1940s: First pmt photon counting system

1970s: First large hemispherical pmt (5 inch)

As Thorn EMI Electron Tubes Ltd 1980s: First low background glass pmts

Rugged pmts for space applications

1990s: First small (1 inch) hemispherical pmtsFirst ultra-low background glass pmts

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Brief History

As Electron Tubes Ltd:1995: High performance pmt modules

X-Ray detection systems

2000: Ultra -low temperature pmts

2005: Signal processing electronics

ET Enterprises Ltd – from May 2007

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Product Range

•Photomultipliers

•Voltage Dividers

•Housings

•Photon counting systems

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Product Range

• Diameter: 19mm to 200mm• Spectral Range:110nm to 900nm• Gain: 103 to >108

• Rise Time: down to <2ns• Window profile: various • Rugged• Low temperature• High temperature• Low background glass

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Main Applications

• High energy Physics• Space exploration• Oil exploration• Nuclear radiation monitoring• Bio-technology• Pollution monitoring• Scintillation spectrometry

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Recent Developments

• Ultra-low temperature photocathodes for use down to -180 C

• Ultra-low background glass: ~50 times lower than standard glass

• All Quartz construction: >200 times lower than standard glass

• Range of standard rugged pmts

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Recent Developments

• High blue/green QE combined with low dark count

• Electro-optical designs to optimise collection efficiency

• Low temperature photocathodes with UV windows

• Encapsulated pmts for direct immersion in liquids

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

BaBar DIRC Detector

• 30mm diameter

• QE

• Water resistant glass

• Large quantity

• Customised base

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

BOREXINO

• 200mm hemi-spherical

• Collection Efficiency

• Encapsulated for Immersion in liquid

• Single electron resolution

• Dark count

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

VLVnT08 – Toulon April 2008

Collection Efficiency

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

WARP

• 78 mm domed window

• Timing

• Operation at LAr temperature

• Single electron resolution

• Dark count

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

DAMA

• 78 mm all quartz

• Collection Efficiency

• Fast timing

• Single electron resolution

• Dark count

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

ICARUS

• 200mm hemi-spherical

• QE and collection efficiency

• Operation at LAr temperature

• Single electron resolution

• Dark count

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Current and Recent Projects

MAGIC

• 25 mm & 38 mm hemi-spherical

• QE and collection efficiency

• Fast timing

• Single electron resolution

• Low gain

VLVnT08 – Toulon April 2008

rrrrrrrrrrrrrrrrrrrrrrbbbbb

Summary of Capability

• Difficult environments

• High QE/Low background

• Range of window profiles

• Single photon electron resolution

• Customisation and Application support

VLVnT08 – Toulon April 2008