27
Introduction to ARIA IP - 60 Anton Hattingh

Introduction to

  • Upload
    faunia

  • View
    38

  • Download
    0

Embed Size (px)

DESCRIPTION

Introduction to. ARIA IP - 60. Anton Hattingh. Content. System overview Connection diagram System Recourses Connections Hardware Features. System overview. Hybrid telephone system with 12 analog PSTN’s & 48 ext. Caller ID service for CO line & SLT - PowerPoint PPT Presentation

Citation preview

Page 1: Introduction to

Introduction to

ARIA IP - 60

Anton Hattingh

Page 2: Introduction to

Content

System overview Connection diagram System Recourses Connections Hardware Features

Page 3: Introduction to

Hybrid telephone system with 12 analog PSTN’s

& 48 ext.

Caller ID service for CO line & SLT

Conference, SMDR, LCR, Call duration control

Collect call barring, Mobile extension

Other services for enterprise communications

- Alarm detection

- External door phone control

- External paging interface,

- External music source interface

System overview

Page 4: Introduction to

General connection diagram

Page 5: Introduction to

System Resources 1/2

DESCRIPTION CAPACITY/BOARD TOTAL

Time Slots 128

CO Line Ports 3/MBU, 3/EMBU, 3/CHB308, 3/CSB316, 8/VOIB, 30/E1HB8

Max. 36

Max Direct Station (DKT, SLT, DSS) Connections

8/MBU, 8/EMBU, 8/CHB308, 16/CSB316, 8/VOIB, 8/E1HB8

Max. 48

Max. Door 2/MBU, 2/EMBU 4

LAN MBU, VOIB, E1HB8 3

MODEM Channel 1/MODU 1

Attendant Positions 5/System

Intercom Links Non-Blocking

Paging- All Call- Internal

1 zone5 zones

Station Speed Dial 100/station, 24 digits each 500

System Speed Dial 24 digits each 500

Last Number Redial 15 ~ 50(by admin programming) 32 digits

Page 6: Introduction to

System Resources 2/2

DESCRIPTION CAPACITY/BOARD TOTAL

CO Line Group 8 8

Station Group 10 10

Conference 3~15 Party All ports are available

Multi-Conference 3~15 Party Max. 3 groups

Internal MOH (13 Music Sources)

1/MBU 1

External MOH 1/MBU 1

External Paging port 1/MBU 1

External Relay Contact 2/MBU, 2/EMBU 4

Alarm Input 1/MBU 1

RS-232C Port 1/MBU 1

DTMF/CPT Receiver channels

16 chs/MBU 16 chs

FSK Receiver channels 16 chs/MBU 16 chs

PFT Circuit 1/MBU, 1/EMBU, 1/CHB308, 1/CSB316 4

Page 7: Introduction to

MBU connectors and LED

※ Available Option: 1. CN2 : E1HB8, CHB308, CSB316 or SLIB8 2. CN4 : MODU 3. CN5 : VMIU or AAFU 4. CN14: VOIB 5. CN9 & CN10: CMU50PR or CMU12PR

LD1 : System running indication

LD2-4 : S/W task indication

SW1 : Default ON

Pole1 : reserved

Pole2 : system trace on

Pole3 : reserved

Pole4 : system backup

SW2 : Backup battery

ON for protection

Status LED

Page 8: Introduction to

System Connections

RJ-11

1: N/A2: DKT-Tip3: SLT-Tip or CO-Tip4: SLT-Ring or CO-Ring5: DKT-Ring6: N/A

CO# : Loop start CO PortSTA# : Hybrid PortDKT# : DKTU Only PortSLT# : SLT Only Port

BKSU

EKSU

BKSU Only

Page 9: Introduction to

Connector Pin-out 1/3

NOTE—When installing DKT or SLT on Hybrid Ports, (MJ2-2,3,4,5,6,7,8), keep the above pin assignment. Otherwise the DKT or SLT will not operate normally.

MBU (CO)

ConnectorPIN Number NO Signal Name

RJ11 1,2 N/A

3,4 CO-T, CO-R

5,6 N/A

MBU (Extension) DKT ONLY

CONNECTOR PIN NUMBER NO SIGNAL NAME

RJ11 1 N/A

2 DKT-T

3,4 ALARM_Detection

5 DKT-R

6 N/A

MBU (Hybrid)

CONNECTOR PIN NUMBER NO SIGNAL NAME

RJ11 1 N/A

2 DKT-T

3,4 SLT-T, SLT-R

5 DKT-R

6 N/A

Page 10: Introduction to

Connector Pin-out 2/3

TERMINAL DKT

CONNECTOR PIN NUMBER NO SIGNAL NAME

RJ11 1 N/A

2 RING

3,4 Reserved

5 TIP

6 N/A

TERMINAL SLT

CONNECTOR PIN NUMBER NO SIGNAL NAME

RJ11 1,2 N/A

3,4 TIP, RING

5,6 N/A

Page 11: Introduction to

Connector Pin-out 3/3

CN13 Pin Assignment (Relay Contact)

CONNECTORNO SIGNAL NAME

4 PIN 1 Relay 1-pin1

2 Relay 1-pin2

3 Relay 2-pin1

4 Relay 2-pin2

MJ3 Pin Assignment (LAN)

Connector Pin Number NO SIGNAL NAME FUNCTION

RJ45 4,5,7,8 RESERVED

1 TX+ Transmit Data

2 TX- Transmit Data

3 RX- Receive Data

6 RX+ Receive Data

Page 12: Introduction to

Terminal/SLT Cabling Distance

Page 13: Introduction to

Expansion Card CHB308

External.• Provides 3 circuits Loop start CO line

interface.• DTMF or pulse signaling to line• Loop current detection• FSK & DTMF CID detection.• Call progress tone detections

Internal.• Provides 8 digital Stations or 8 SLT station

circuits.• FSK & DTMF CID detection and Generator. • +36V Power Circuit for SLT feeding• SLT feeding Current is 20mA at 900ohm

loop impedance.

CO Line and Hybrid Board (3 CO + 8 HYB)

Page 14: Introduction to

Expansion Card CSB 316CO Line and SLT Board (3 CO + 16 SLT)

External.• Provides 3 circuits Loop start CO line

interface.• DTMF or pulse signaling to line• Loop current detection• FSK & DTMF CID detection.• Call progress tone detections.

Internal.• Provides 16 SLT station circuits.• FSK & DTMF CID detection and Generator.• +36V Power Circuit for SLT feeding• SLT feeding Current is 20mA at 900ohm

loop impedance.

Page 15: Introduction to

Expansion Card SLIB 8SLT Board (8 SLT’s)

Internal.• Provides 8 SLT station circuits.• FSK & DTMF CID detection and

Generator.• +36V Power Circuit for SLT feeding• SLT feeding Current is 20mA at

900ohm loop impedance.

Page 16: Introduction to

Expansion Card E1HB8E1 Digital trunk & 8 Hybrid

• CN5 on the MBU, but not on the EMBU• E1 digital trunk: maximum 30 CO lines at the same time• 8 Hybrid ports that provide DKT or SLT connection• 2.048Mbps E1 line as CAS(Channel Associated Signaling)• HDB3 CODE• DID, DOD, and TIE according to each country’s specifications• Pulse dialing, DTMF dialing, and MFC-R2 signaling(30 channels at the same time)• SLU8(Single Line Interface Unit: 8 ports• CN6, CN7 on the E1HB8• +36V power circuit for SLT feeding• Single Line Interface circuit: 8 EA

Page 17: Introduction to

Add on board MODU

MODEM function board

  MODU provides analogue modem connection. MODU should be installed on the CN4 Supports Bell, ITU-T, V.34, V.32BIS, V.90 Protocol 300bps up to 33Kbps speed rate Automatic rate negotiation 

Modem function board

Page 18: Introduction to

Add on board VMIU

• VMIU provides 4 channel Record/Play• VMIU provides Time & System prompt• All message are saved in Flash memory• Max record time

- Prompt : 8 Min. - System greeting : 24 Min - User record time : 99 Min • Max. Number of User Voice Message: 800ea

Note : User Greeting does not lost by system power off or reset because of this message is stored in FLASH memory

Voice Mail Interface Unit

Page 19: Introduction to

Add on board AAFUAuto Attendant Function Unit

• AAFU provides 4 channel Record/Play• AAFU provides Time & System prompt• All message are saved in Flash memory• Max record time

- Prompt : 8 Min. - System greeting : 24 Min - User record time : 9 Min • Max. Number of User Voice Message: 800ea

Note : User Greeting does not lost by system power off or reset because of this message is stored in FLASH memory

Page 20: Introduction to

Add on board VOIB & VOIUVoice over Internet Protocol Interface board

Item Specification

LAN Interface 10 / 100 Base-T Ethernet(IEEE 802.3)

Speed 10 Mbps (Auto-Negotiation)

Duplex Half Duplex or Full Duplex(Auto-Negotiation)

VoIP Protocol H.323 Revision 2

Voice Compression G.711/G.726/G729/G.723.1

Voice/Fax Switching T.38

Echo cancellation G.165

• VOIB can be installed on the basic MBU• Provides the Ethernet interface for S/W applications and VoIP features .• Optional VoIP daughter board.(VOIU)• Maximum Capacity: 8 channels -VOIB provides four(4) VoIP channels. -VOIU provides four(4) VoIP channels.

Page 21: Introduction to

Add on board CMP50PR & CMU12PRCall Metering & Polarity Reversal Detection unit 50Hz and 12Hz

CMU50PR (Call Metering-50 Hz & Polarity Reversal Detection unit)• Provides 3 channels Call Metering detection for 50Hz • Provides 3 channels of Polarity Reversal Detection • It can be installed on the MBU, EMBU, CHB308 or CSB316

CMU12PR(Call Metering-12KHz & Polarity Reversal Detection unit)• Provides 3 channels Call Metering detection for 12 KHz or 16Khz• Provides 3 channels of Polarity Reversal • It can be installed on the MBU, EMBU, CHB308 or CSB316

Page 22: Introduction to

Proprietary TerminalsMODEL DESCRIPTION

LDP-7224D 3 Line LCD display, 24 Flexible Button,3 Soft keys, Naviga-tion key

LDP-7208D 2 Line LCD Display, 8 Flexible Button

LDP-7248DSS 48 Button DSS Console

LDP-DPB Door Phone Box

LDP-7248DSS LDP-Door phoneLDP-7224D LDP-7208D

Not Compatible with OptiCon IP and GDK Systems.

Page 23: Introduction to

IP TerminalsMODEL DESCRIPTION

LIP-7024LD 3 Line LCD display, 24 Flexible Button,3 Soft keys, Navigation key, Dual LED,Calender,Scheduler

LIP-7024D 3 Line LCD display, 24 Flexible Button,3 Soft keys, Navigation key,Dual LED

LIP-7016D 3 Line LCD display, 16 Flexible Button,3 Soft keys, Navigation key, Dual LED

LIP-7008D 2 Line LCD Display, 8 Flexible Button

LIP-7024D LIP-7016DLIP-7024LD LIP-7008D

Page 24: Introduction to

Maintenance

PSTNDial-up Connection

Off-site (Remote)Maintenance

Data Network

In-site maintenance

Digital Terminal Admin

Maintenance Console

On-site & Off site maintenance through RS-232C, Ethernet, Modem

On line PC Admin: DB up/download, Diagnostics, S/W upgrade, PC AdminOff line PC Admin (PC Admin Pro)Speed Editor for system speed dial

User level admin program – adjustable level program

Page 25: Introduction to

Voice Mail / Auto Attendant

Voice MailSMS Notification to virtual extension (mobile extension)4 ch. / Max. 100 min recording time/ 25 min greeting / 800 user message recordingMax. 100 system greetings / Max. 25 min

Optional Voice Mail and Auto-Attendant

Auto-Attendant : 4 channels / 10 min recording / 25 min system greeting

Page 26: Introduction to

Networking

SIP / H.323 proxy registration

Business models for SIP operator / Nortel IP platform

ARIA IP – 60 Voice Networking

Page 27: Introduction to

Questions?