Introducing the bellavista™ 1000†
A new generat ion of vent i lat ion that supports you across care sett ings.
bellavista™ 1000 Engineered for clinicians. Optimized for patients.
A next generation ventilator that combines cutting edge technology to bring you simplicity in clinical practice. Delivering…
Performance: State of the art technology. Streamlined hardware that’s compact, powerful and durable. Software intelligence that’s clinically proven and highly responsive.
Flexibility: User centric design that’s as customizable, navigable and intuitive as using your smartphone.
Value: Configurable to meet the needs of your clinical practice.
2
Providing efficient ventilation and lung protection that’s focused on:
• Minimizing respiratory distress and improving comfort with unique automated synchronization features
• Reducing workload for health care professionals with AnimatedLung and VentSummary views
• Versatility with modes of ventilation and an upgradable platform to deliver a wide range of possibilities and solutions
Technology features
• Powerful and durable turbine drive enables a compact design and robust performance with extended service intervals. Provides Peak Flows up to 260 L/min and low cost of ownership
• 4 Hours battery life expands your reach during transport
• Configurable to meet the needs of your clinical practice
• 13.3" touch smart screen with brilliant full HD resolution
• Vent box: 13.8" W X 12.9" H X 8.7" D
• Weighs: 12.8 Kg
• Stores up to 20 clinician preconfigured profiles
Simplified preventive maintenance for a low cost of ownership
12 Month interval: Check battery life, calibration and functional testing, replace filter kit (turbine inlet filter, turbine exhaust filter, cooling fan inlet filter)
Portable, space efficient design
Compact hardware enables a footprint that allows you to ventilate on the go, during intra-hospital transport, while supported by a minimum of 4 hours battery life. The easy-to-steer transport cart features adjustable height, configurable storage shelves and brackets, silicone handle to grip cables and hoses, and oversized easy roll, lockable wheels.
Offering you state of the art technology and an innovative user interface that supports you in your daily challenges across care settings
3
Signature software features that make the bellavista unique
Settings assist
Use Settings Assist to see ventilation changes before you apply them. Changes in timing, cycling and I:E ratio can be easily overviewed and support you in choosing the best settings for your patient.
Smart user interface
Use the touch screen to access our quick start menu to begin ventilation. Easily configure settings to support your daily patient routine and display desired home screen parameters. bellavista can store up to 20 configurable user profiles with 3 always available on screen for quick access. Our system delivers you the ultimate flexibility so you can focus on the essentials.
AnimatedLung
Use this dynamic tool to visualize the patient’s lung condition at a glance. The simple graphical interface helps highlight changes in the patient’s lung condition by showing various states of compliance, resistance and spontaneous breathing activity.
VentSummary
VentSummary displays an overview of the most relevant weaning criteria, such as spontaneous breathing, PEEP and pressure support. The limits can be individually configured. As soon as the patient’s respiratory parameters are within the desired range, Vent Summary switches to green and a timer indicates how long the patient maintains your specific extubation criteria.
4
Flow
Volume
Pressure
PEEP Trigger
Leakage
Pressure overshoot caused byinadequate rise time setting
Rise
Advanced synchronization
Available for Invasive (IV) and Non-Invasive (NIV) ventilation. NIV is supported by the below synchronization tools to deliver high fidelity therapy, synchronized to every patient’s breathing pattern. It recognizes the patient’s expiratory effort immediately, thus helping to reduce the work of breathing and breath-stacking. The inspiratory and expiratory triggers adapt to variable leaks to maintain optimum performance.
Smart software working behind the scenes deliver auto.sync, auto.rise, auto.leak. These features ultimately work together to support patient safety and comfort.
auto.sync
Releases the patient from a fixed or manual expiratory trigger setting to optimize synchronization during spontaneous breathing. To ensure a smooth transition from inspiration to expiration, auto.sync detects and calculates several criteria with a high sampling rate.
auto.leak
Automatically and adaptively balances highly variable inspiratory and expiratory leaks up to 120 L/min. This feature and our sensitive flow or pressure trigger prevents failure and synchrony problems for your patient.
auto.rise
Adapts and optimizes rise time with a breath-by-breath calculation and prevents overshoot to relieve you from the challenge of finding the correct rise time for your patient.
5
Parameter Specification
Area of application • Intensive Care Unit (ICU)• Intermediate Care (IMC)• Emergency Room (ER)• Intrahospital transfer
Patient Types Adult, Pediatric ≥ 6 kg
Technology High performance turbine ventilator
Ventilation Modes: • Pressure controlled• Volume controlled• Flow Pattern• Apnea ventilation• Backup Modes
CPAP, PCV, P-A/C, PC-SIMV, PSV*, beLevel, APRV, S, S/T*, TVCV, V-A/C, VC-SIMV, PLV (Pressure Limited Ventilation)Square, Decelerating 50 %, DeceleratingP-AC, PC-SIMV, V-AC, VC-SIMVPSV*, S/T*
Peak inspiratory flow 0-260 L/min
Peak expiratory flow 0-180 L/min
Inspiratory pressure, IPAP 2-60 cm H2O
Psupport 0-60 cm H2O
PEEP, EPAP 0-40 cm H2O
Tidal volume 40-2500 mL Adult, Pediatric
Inspiratory time 0.1-10 sec
Respiratory rate 0-100 bpm, Adult, Pediatric
I:E ratio 1:299 - 59:1
Inspiratory Trigger Flow 0.1-20 L/min, Pressure 0.1-15 cm H2O, Trigger off
Expiratory Trigger auto.sync, 5-90 % manual
Rise time auto.rise, 0-2000 ms manual
Leakage compensation
auto.leak, automatic in-/expiratory leak compensation up to 120 L/min
Curves Pressure, Flow, Volume, ATC
Loops Pressure Volume, Pressure Flow, Flow Volume
Monitoring 56 online parameters
Trending 14 days realtime trending, 1 year parameter trending
Maneuvers Manual Breath, Configurable Sigh*, Inspiratory Hold, Expiratory Hold, P0.1 (Occlusion Pressure), AutoPEEP
Suction tool Increase of oxygen concentration for a limited period of time: Default: Adult/Pediatric: 100 % O2 for 2 min
ATC Automatic tube compensation for Endotracheal Tube/Tracheostomy Tube. Configurable for in-/expiratory breaths
Parameter SpecificationWeaning protocol VentSummary
Graphics AnimatedLung, VentSummary
Oxygen 21 %-100 %
Alarms VtExp, Vt, VtInsp, MVExp, MVInsp, MV, Apnea, Ppeak, Leak, FiO2
Patient circuit type Single Limb, Dual Limb, Adult/Pediatric**
Interfaces RS232, Ethernet, 2 × USB, Nurse Call, bellavista Bus
Connection protocols VueLink, Intellibridge, HL7
Dimensions (w × h × d) 13.8" X 8.7" X 12.9"
Screen 13.3" Full HD Color TFT Touchscreen
Battery time minimum of 4 hrs for a fully charged battery**
Oxygen supply 21.75 - 101.5 psi
Air Inlet built-in turbine
Weight 12.8 kg
Protection class IP21
Power input 100-240 VAC ± 20 % / 50–60 HzLow voltage input 24 VDC / 3.5 A
Mode Description Invasive Non-Invasive
Pressure controlled
P-A/C Pressure Assist Control Ventilation
PC-SIMVPressure Controlled-Synchronized Intermittent Mandatory Ventilation
beLevel Biphasic Ventilation
APRV Airway Pressure Release Ventilation
CPAP Continuous Positive Airway Pressure
PSV Pressure SupportVentilation * *S Spontaneous
S/T Spontaneous/Timed * *T Timed
Volume controlled
V-A/C Volume Assist Control Ventilation -
VC-SIMVVolume Controlled-Synchronized Intermittent Mandatory Ventilation
-
* Not available in Pediatric ** See manual for more detail
Technical specifications overview
6
Contact Vyaire today.Call Call 1.833.327.3284 or visit vyaire.com
Product Description Part #
bellavista 1000 US Ventilator unit.Includes iFlow 200S proximal flow sensor, expiration valve mount, exhalation valve with L-connector, expiration valve adaptor, Easy lung 1L, non-heated dual limb circuit, bacteria filter, 02 Hose, O2 adapter connector, power cable and user manual
301.100.030
Accessory Description Part # i.flow 200 Flow Sensor Advanced flow sensor. Single patient use.
Pack of 10301.328.010
Exhalation Valve Exhalation valve with 10" pressure control line and L- connector. Pack of 10
302.231.001
Cart Adjustable height (37.4" – 45.3") 301.105.000
- Cart Basket 15" W x 10.25" D x 5.5" H 302.520.000
- Cart Drawer 14" W x 10" D x 4.3" H 304.138.000
- Oxygen Cylinder Holder Holds up to 2 cylinders 301.551.000
- Humidifier Bracket Double 304.072.000
Support Arm Stable single joint. Includes rail mount and twin tube holder 301.106.000
- Tube Support Extension Supports weight of all tubing 302.792.000
- Single Tube Holder Supports single limb circuits 302.792.000
Water bottle holder Adjustable height to support humidifier bags 304.584.000
Adult Smart Lung 2L Simulates adult lungs with adjustable compliance and resistance settings
302.730.000
Pediatric Smart Lung 0.5L Simulates pediatric lungs with adjustable compliance and resistance settings
300.400.004
Nurse Call Connector Used for both open or closed formats 301.115.000
Data Communication Interface Adaptor
For PDMS and Vuelink/Intellibridge connections 302.079.000
Ordering information
7
vyaire.com† bellavista is a trademark of imtmedical. imtmedical is doing business as Vyaire Medical.
U.S. distribution only bellavista is a trademark of imtmedical. imtmedical is doing business as Vyaire Medical. © 2019 Vyaire. Vyaire, the Vyaire logo and Vyaire AirLife are trademarks or registered trademarks of Vyaire Medical, Inc., or one of its affiliates. VYR-US-1900162
G L O B A L H E A D Q U A R T E R S
Vyai re Medica l , Inc.26125 Nor th R iverwoods B lvdMettawa, I L 60045, USA