Safety, Efficiency, Predictability New Generation iSert®
The iSert® Preloaded IOL Implantation System now provides easier handling and greater protection of the IOL
— Safety: an untouched IOL in a disposable, closed preloaded iSert® system for ultimate sterility, reduced lens damage, and reduced exposure to contaminants.
— Efficiency: easily repeatable and disposable system that reduces the time-consuming aspects of inserter preparation, cleaning, and sterilization. Cuts the number of steps required with ordinary procedures in half.
— Predictability: ergonomic design provides consistent, controlled, and safeguarded delivery of the preloaded IOL that is predictable and reproducible.
Enhancing premium IOL performance and resultsPrecise vision correction for patients with astigmatism
— Unique Design: A unique hybrid, one-piece, two-material design with non-stick PMMA haptic tips and the sharpest square edge provide rotational stability and controlled centration for more consistent IOL calculations and improved refractive outcomes. Precise astigmatism correction with proprietary Aspheric Balanced Curve (ABC) design that restores image sharpness and visual acuity even when lens is decentered over 0.2mm.
— HOYA Optics: Pristine optics – the result of our proprietary lathe-cut, pad polished manufacturing process means higher optical precision.
— Mini-INcision: The non-wound-assist benefit of as low as a 2.2 mm incision reduces residual post-operative astigmatism.
Better Measurement for Better Toric IOL Results Enhance lens placement and minimize postoperative astigmatism
— IOL Suggestions: The HOYA Toric Calculator will suggest several HOYA Toric IOLs from which you may choose to treat a patient’s refractive cylinder resulting from corneal astigmatism. Astigmatic correction will be calculated for all toric lens powers and a non toric lens as well.
— Axial Placement: The Calculator will suggest intra-operative axial placement of the IOL that is intended to minimize postoperative astigmatism.
— Visualizing the Placement: Along with the recommended axis for TIOL placement, the Calculator provides an image of the eye with the incision location, steep and flat corneal axis, and the axis of placement for the TIOL.
Other Key Features
Toric design based on the proven 100% Hydrophobic Acrylic HOYA Monobloc design (iMics1)
The non-wound-assist benefit of up to 2.2 mm incision reduces residual post-operative astigmatism
Unique Preloaded iSert® delivery system with as low as a 2.2 mm incision
270˚
90˚
135˚
315˚
45˚
225˚
180˚
Axis Markings (Posterior)
Optimized Sharp Edge2,3,4
0˚6.
0 m
m
PMMA Non- Stick Haptics
Soft Acrylic
HOYA Toric Specifications
Specification Monobloc, blue-light filter5
Optic Material Hydrophobic soft acrylic (UV-absorbing acrylic resin with blue-light filter)
Haptic Material Hydrophobic soft acrylic (UV-absorbing acrylic resin with blue-light filter) with PMMA haptic tips
Optic Configuration/ Design
Biconvex toric Anterior: aspheric, asphericity = ~-0.18 µm Posterior: toric
Manufacturing Lathe-cut and pad polished
Haptic Configuration Modified C− loop, 5 ̊angulation
Dimension (Optic/OAL) 6.0 mm/12.5 mm
Spherical Power +10.0 to +30.0 D
Cylindrical Power1 T3 to T9 (see table above)
A-constant6 118.4
Optimized Optical Constants
Haigis a0 = 1.13; a1 = 0.4; a2 = 0.1 Hoffer Q pACD = 5.33 Holladay 1sf = 1.54 SRK/T 118.6 SRK II 118.7
Method of Sterilization Ethylene oxide (EO)
Incision As low as 2.2 mm
Refraction Index 1,52
Model 351
Power Cylinder on the IOL Plane
Power Cylinder on the Corneal Plane
T3 1.50 D 1.03 D
T4 2.25 D 1.55 D
T5 3.00 D 2.06 D
T6 3.75 D 2.58 D
T7 4.50 D 3.09 D
T8 5.25 D 3.61 D
T9 6.00 D 4.12 D
For more information: HOYA Medical Singapore Pte Ltd 455A Jalon Ahmad Ibrahim Singapore, 639939 (+65) 6863 4809
1. On IOL plane2. Werner L, Tetz M. Edge profiles of currently available intraocular lenses and recent improvements. European Ophthalmic Review. 2009;3(2):74-76.3. Kohnen T, Fabian E, Gerl R, et al. Optic edge design as a long-term factor for posterior capsular opacification rates. Ophthalmology. 2008;115(8):1308-1314.4. Nishi O, Nishi K, Wickström K. Preventing lens epithelial cell migration using intraocular lenses with sharp rectangular edges. J Cataract Refract Surg. 2000;26(10):1543-1549.5. The HOYA iSert® Toric 351 T3 / T4 / T5 / T6 / T7 / T8 / T9 achieves a transmittance factor close to that of the human lens. It blocks almost all ultraviolet light as well as some
short-wavelength blue light.6. This A-constant number is presented only as a guideline for lens power calculations. It is recommended that A-constant measurements be based on the surgeon’s experience
and measuring equipment.
iTraceTM is a trademark of Tracey Technologies, Corp.
12.5
mm
Anterior Posterior
ABC Aspheric Design
Toric
VDLA
-TB4
-EN
-29.
03.2
012/
1 ©
2012
HO
YA S
urgi
cal O
ptic
s, In
c.