Intelligent Tri-Mode Terminal – ETM Purple Features: Intelligent Tri-Mode Terminal, AT mode, ET Mode, JET Mode SMS, IP or CSD operation and/or configuration options Small form factor, to fit under meter covers or other enclosures with size constraints 2G (GSM/GPRS) Connectivity 3G (HSPA/UMTS) Connectivity 4G (LTE) Connectivity Combined or separate RS232 Serial & Power Connectors High speed USB RS422 and RS485 functionality Signal strength LED indicator 5 - 35V power input. 7 - 35V for last Gasp variants FME M antenna connector ETM Purple user guide. 1802-20170003 R07 ETM-Purple User Guide

Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or [email protected] 1802-20170003 07 ETM Purple user guide.docx

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Intelligent Tri-Mode Terminal – ETM Purple

Features: ◩ Intelligent Tri-Mode Terminal, AT mode, ET Mode, JET Mode ◩ SMS, IP or CSD operation and/or configuration options ◩ Small form factor, to fit under meter covers or other enclosures with size constraints ◩ 2G (GSM/GPRS) Connectivity ◩ 3G (HSPA/UMTS) Connectivity ◩ 4G (LTE) Connectivity ◩ Combined or separate RS232 Serial & Power Connectors ◩ High speed USB ◩ RS422 and RS485 functionality ◩ Signal strength LED indicator ◩ 5 - 35V power input. 7 - 35V for last Gasp variants ◩ FME M antenna connector

ETM Purple user guide. 1802-20170003 R07

ETM-Purple User Guide

Page 2: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Contents Contents ............................................................................................................................................ 2Revision History ................................................................................................................................. 3Introduction ........................................................................................................................................ 3

Nomenclature ................................................................................................................................. 3Overview ........................................................................................................................................ 3Applications .................................................................................................................................... 3Tri-Mode Operation ........................................................................................................................ 4

Physical Dimensions ......................................................................................................................... 5Separate Power RJ12 & Serial 10 pin Boxhead Connector .............................................................. 5Combined Power & Serial RJ45 Connector ...................................................................................... 6USB Communications Port ................................................................................................................ 6Antenna ............................................................................................................................................. 6SIM Card ........................................................................................................................................... 6

SIMPin......................................................................................................................................................7

Indicator Lights .................................................................................................................................. 7LED Behaviour - Normal Start Sequence ...................................................................................... 7Green LEDs ................................................................................................................................... 8Orange LEDs ................................................................................................................................. 8

Installation ....................................................................................................................................... 10Initial Start-up & Configuration ......................................................................................................... 10

Typical Startup Sequence ............................................................................................................ 10ET Mode/Configuration .................................................................................................................... 11

Putting the Unit into ESC Mode ................................................................................................... 11ET Command Table ..................................................................................................................... 12

Last Gasp Mode Operation ............................................................................................................. 14AT Mode Operation ......................................................................................................................... 15

Common useful AT commands for basic operation include: ........................................................ 15SMS Specific Commands ............................................................................................................ 16AT Commands for Incoming Circuit Switch Data Calls ................................................................ 16

JET Mode Operation ....................................................................................................................... 16JET Command table .................................................................................................................... 16

JETConfigurationchangeresponses.......................................................................................................18

Installing the configuration tool in Windows 7. ............................................................................. 19Localconfiguration.................................................................................................................................25

Page 3: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 3 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Revision History Date Revision Editor Description 2016-05-01 201605RV01 Patrick Paffard First released version 2016-05-13 201605PRV02 Carl Håkansson Added signal strength picture,

Added LED behaviour from Main code 2017-02-13 R03 Christian Leierer Added Last Gasp information 2017-02-22 R04 Christian Leierer Change parameters in tables 2017-06-13 R05 Carl Håkansson Added config tool information 2017-08-04 R06 Carl Håkansson Changed Nomenclature 2017-08-04 R07 Carl Håkansson Changed part numbers

Introduction

Nomenclature The ETM Purple variants incorporate the Cinterion BGS2, BGS5, EHS5, EHS6 or ELS61 module and are intended for worldwide use (network and regulatory approvals permitting). Terminal Nomenclature/History Description Part

number Module Installed

ETM Purple 2G, RJ12, Boxhead 71271 BGS2-E ETM Purple 2G, RJ12, Boxhead, USB 71272 BGS5-E ETM Purple 2G/3G Penta Band, RJ45, USB 71280 EHS6 ETM Purple 2G/3G Penta Band, RJ12, Box head, USB, Last Gasp 71284 EHS6 ETM Purple 2G/3G/4G, E-band, RJ45, USB 71423 ELS61-E ETM Purple 2G/3G/4G, RJ12, Boxhead, USB, Last Gasp 71426 ELS61-E ETM Purple 3G/4G US-Band, RJ45, USB 71355 ELS61-US ETM Purple 3G/4G US-Band, RJ12, Boxhead, USB, Last Gasp 71356 ELS61-US ETM Purple 3G/4G AUS-Band, RJ45, USB 71357 ELS61-AUS

Overview The ETM Purple range of products, are intelligent industrial terminals designed for M2M (Machine to Machine) communications. With 2G/3G & 4G connectivity, intelligent Tri-Mode operation and small form factor they provide the ideal communications solution for electrical metering or other applications utilising serial communications.

Applications Typical applications include: ◩ RS232, RS422/485 or USB communications interface for electrical meters and data

concentrators ◩ Serial communications interface for other devices such as PLC’s, Irrigation controls, Security

and/or access systems, data loggers ◩ As a device for sending SMS alarms notifications based on AT commands from a connected

PLC, PC or Server

Page 4: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 4 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Tri-Mode Operation The unit can be operated in a number of ways to achieve different functional outcomes, depending on the requirements of the device to which the unit is connected, and/or the interaction with any back-end/server. The ETM Purple can support CSD or IP connections and SMS configuration or status queries. The following is a simplified block schematic to assist in understanding the operational capabilities of the unit.

Mode/Command Structure

Purpose Interface Method

ET Commands The external processor is used to control the start sequence of the modem and make default operational settings. It is also used to configure "Last Gasp" functionality (if applicable) and other features.

ET commands sent to serial port if in ESC mode SMS of a subset of ET commands sent to the units phone number (note SIM needs to have SMS activated)

AT Mode Depending on the setting made above the unit can be operated as a basic 2G/3G/4G modem using AT commands to drive the unit

AT commands sent to the serial or USB port

JET Mode Provides intelligent operational functions such as; - TCP tunnel - CSD tunnel - TCP Server - Serial to TCP Server - Status Logging > sending to server for

monitoring (by others)

JET commands sent to the serial port, or by SMS or by TCP

Note that there may be a charge associated with the provision of JET code, and that it is possible for customers to use the modem and to load their own Java™ code for a specific application. ETM will not provide un-compiled JET code for use by others, it is the customers responsibility to develop their own code using the resources available for the BGS5, EHS5, EHS6 or ELS61 module.

External Processor ET Commands

Java Engine JET Mode

EHS5/6 Wireless Module AT Commands

ETM Purple Tri-Mode Intelligent terminal

RS232 Serial ET Mode AT Mode JET Mode

USB AT Mode

(Modem Can be powered by USB)

TM

Page 5: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 5 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Physical Dimensions

Separate Power RJ12 & Serial 10 pin Boxhead Connector Some models of ETM Purple utilises a 6-pin RJ12 connector for power, pin allocations are shown below. Pin Function Looking at Modem Socket 1 Power Supply (+5 to +35VDC) (+7 to 35VDC

for Last Gasp)

2 Not Used 3 Not Used 4 Not Used 5 Not Used 6 GND

Some models of ETM Purple utilises a 10-pin box head connector for communication, pin allocations are shown below. Pin Function Looking at Modem Socket 1 DCD Out

2 DSR Out

3 RXD Out

4 RTS In

5 TXD In

6 CTS Out

7 DTR In

8 RING Out

9 GND

10 Not Used

70.0

52.0

24.0110Approx.

SIM Cover

RJ45 Serial & Power Connector

Mini-USB Connector

1 2 3 4 5 6

Page 6: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 6 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Combined Power & Serial RJ45 Connector Some models of the ETM Purple utilises a single RJ45 combined power and serial connector, pin allocations are shown below. Pin Function Looking at Modem Socket

1 Power Supply (+5 To 35VDC, 400mA @ 12VDC) (+7 To 35VDC for Last Gasp)

2 DCD 3 DTR 4 GND 5 RX 6 TX 7 CTS 8 RTS

USB Communications Port Mini-USB port for communications directly to the EHS6 module within the modem, drivers for Windows need to be installed on the PC to allow access to this port. The modem can be powered from the USB assuming the USB can deliver a voltage in the range of +5 to 35VDC(+7V to 35V Last Gasp), if not a separate power supply via the RJ45 connector is required. Note: The NES DCN3000 data concentrator can be set to 12VDC output USB power. AT commands and responses are available via the USB port.

Antenna The ETM Purple has a standard FME M antenna Plug on the end of an approximately 110mm cable.

FME M Antenna Connector

SIM Card The SIM card connector is located on the underside of the ETM Purple Terminal. The unit supports both 3V or 1.8V SIMs. Any SIM card used needs to be correctly provisioned for the services and network upon which it is intended to be used.

If the terminal is intended to be used for remote access to a device a terminating data number for Circuit Switch Data (CSD) will need to be provisioned by the network operator, this number will usually differ from any voice/SMS number. Other key configuration settings are; ◩ Telstra NextG® SIMs when used for CSD require 2620 bearer capability

Caution Take care to ensure that only the correct connectors are used or mechanical damage to the pins may result.

Caution Always disconnect power supply before inserting or removing SIM Card. Care should be taken in inserting and removing the SIM card so as not to damage the SIM holder or cover.

1 2 3 4 5 6 7 8

Page 7: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 7 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

SIM Pin If the SIM used has a PIN either;

• The unit can be configured to enter the SIM pin, refer applicable section of this manual OR

• The SIM PIN should be deactivated, insert the SIM in a mobile phone and deactivate then transfer the SIM into the ETM Purple unit.

Indicator Lights

Looking at underside (SIM access side) of unit.

LED Behaviour - Normal Start Sequence

LED 1

LED 2

LED 3

LED 1

LED 2

LED 3

GreenLED1:ONGreenLED2:ONGreenLED3:ON

GreenLEDsremainON

OrangeLED1:ON(IndicatingthatModulehasbeenfound)

OrangeLED2:ON(IndicatingthatModulehasbeenpowered-upOK)

OrangeLED3:ON(IndicatingthatSIMcardhasbeenfound)

AllLEDsturnOFF

OrangeLED1:Flashing4timesOrangeLED2:Flashing4timesOrangeLED3:Flashing4times

AllLEDsturnOFF

ThenSeeLEDBehaviourBelow

Page 8: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 8 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Green LEDs Green LED 1 Function Slow Flash 500ms On / 500ms Off Searching for mobile network Double Flash 3s Off / 100ms ON / 100ms OFF / 100 ms ON

Active 2G network connection

Triple Flash 3s OFF / 100ms ON / 100ms OFF / 100 ms ON / 100ms OFF / 100ms ON

Active 3G network connection

Four time Flash 3s OFF / 100ms ON / 100ms OFF / 100 ms ON / 100ms OFF / 100ms ON / 100ms OFF / 100 ms ON

Active 4G network connection

Green LED 2 Function ON Internet Service Provider connection (Active PDP

context and IP address) OFF No Internet Service Provider connection

Green LED 3 Function Rapid Flash Sending Data ON Receiving data from host (turn off after 2 seconds) OFF No data transmission occurring

Note: All LED will flash at boot up

Orange LEDs Orange LED 1 Function Flashing RSSI < -105 dBm or no SIM detected ON RSSI ≥ -105 dBm (Poor signal) OFF Not registered to mobile network ≥

Orange LED 2 Function Flashing No SIM detected ON RSSI ≥ -89 dBm (Fair signal) OFF RSSI < -89 dBm or Not registered to mobile network

Orange LED 3 Function Flashing No SIM detected ON RSSI ≥ -73dBm (Good signal) OFF RSSI < -73dBm or Not registered to mobile network

Page 9: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 9 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

-110 dBm (no signal)

<-100 dBm (poor signal)

-100 to -86 dBm (fair signal)

-85 to -70 dBm (good signal)

> -70 dBm (excellent signal)

Signal strength levels.

Page 10: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 10 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Installation 1. Connect a suitable serial interface to the modems RJ45 port or 10 pin box header depending

on model, see previous section for pinout details. 2. Fit a suitable antenna to the unit’s FME antenna lead. 3. Install a SIM card enabled for the services you intend to use. If the terminal is intended to be

used for Circuit Switch Data (CSD) a SIM with a terminating data number will need to be provisioned by the network operator, this number will usually differ from any voice/SMS number. Note that for Telstra you will need to request;

2620 bearer capability (Telstra NextG™ Sims) 4. Connect the power supply. (The unit accepts a broad range of voltages from +5 to +35VDC) 5. Refer to related sections of this manual for information on configuring the unit for the intended

mode of operation.

Initial Start-up & Configuration The unit may be delivered in the following states depending on customer request, note that additional costs may apply for certain functionality. As delivered State

Description Start-Up

Standard – no JET Code

Basic modem that may be controlled by AT commands from devices such as a PC, electrical meter or PLC

When the units power is connected and the start-up sequence completed (approximately 20-30 seconds) the serial and USB ports will become available at the set baud rate for AT commands

With JET Code When JET code is installed in the unit custom functionality become available

When power is connected and the start-up sequence completed (approximately 20-30 seconds) the serial and USB ports will become available at the set baud rate for AT commands. Note that dependant on the JET code and actual state the serial and/or USB ports may not be accessible as they may be busy. Depending on the configuration settings associated with the JET code the JET code may auto run or be manually started

Typical Startup Sequence

AT commands may now be sent to the unit.

Page 11: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 11 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

ET Mode/Configuration ET Mode runs in the background irrespective of whether the unit is being used as a basic AT modem controlled via AT commands from a connected device, or the JET functionality is being used. ET mode enables configuration of the unit to run in a specific way, controls the Last Gasp functionality (if applicable) and allows for some SMS based diagnostic queries. ET commands can be sent to the unit via the serial port (RJ45 or box head) when the unit is in ESC mode, a subset of the commands may also be sent by SMS to reconfigure the unit or query the unit's status. All commands must start with “ET” and end with Carriage Return(<CR> / ASCII 13). The response will be: “Message Body” + “OK”

Putting the Unit into ESC Mode To enter ESC mode and configure the ET functions the unit must be started while holding the ESC key down in an active terminal window. The example below uses ETM's Term42 program and valid terminal program will suffice. 1. Open and Setup a suitable Terminal Program

2. Power up Unit while holding down ESC key

You are now in ESC mode and ET configuration commands and queries can be sent to the unit.

Prior to starting the unit Open a terminal program and ensure the correct serial port is open, the baud rate is 115200 and the cursor is flashing in the terminal window

Make sure you hold the ESC key on until the unit confirms "Escape Pressed!"

Page 12: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 12 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

ET Command Table

ET Command Description Command Method ESC (Serial in ESC Mode), SMS

Response

ETI Query Modem Information ESC, SMS Modem Info: VAR:Standard POWIN:7414mV MODV:3912mV CAPV:3712mV IMEI:004401081945897 SCID:89462046001000364372 MTemp:29degC BSWS:2.2.6.4 SWS:2.2.9.24 HWS:71357 PCBS:B06031703 SWC:0 PUC:6 PFC:0 MRC:0 Module Info: ATI1 Cinterion ELS61-AUS REVISION 01.001 A-REVISION 00.004.00

ETNET

Query Network Information ESC, SMS Network Info: SIM:READY(1) CREG:1 SigQ:8 Operator:"Tele2" LAC:00D4 CELL:0D4133A ACT:3G UARFCN:10787 PSC:275 EC/n0:-6.0 RSCP:-100

ETMCU Query MCU Information ESC, SMS MCU Info: Bootloader version:2.2.6.4,Build time: Jan 26 2017 10:18:49 Firmware version:ETM Purple SW:2.2.9.24, SVN version: TBD:TBD, Build time: Feb 1 2017 10:00:39 Binary image size:82420 bytes STM32 SOC ID:0x4321554238314746ffff0033 FLASH size:256kb

ET&V Query Active Profile ESC, SMS PROFILE: CID:001 LGNR:+46709032555026 IPADD:000.77.219.177:8608 APN:maingatelan.telia.se HSD:10(min) HSP:10(min) LGPFT:0(s) LGBT:3600(s) LGPRT:0(s) RT:1440(min) Max SMS limit:50

ET&T Query Timers Profile ESC, SMS TIMERS: MRTC:00/00/00,00:00:00 RTC:00:02:38(h:m:s) PFTS:0(s) RT/RTR:1440/1437(min) BkpWTR:744(s) HSPTR:464(s) HSDTR:464(s)

ETRVL Query CAP Voltage level ESC, SMS CAP VOLT: 3838mv ETGIS Query Short format

Information ESC, SMS #2,CuID,UID,ETGIS,0,004401081945897,71357*B0

6031703,2.2.9.24,89462046001000364372,9,OPC,3,00D4,0D4133A,3.706,33,0,0,0#

ETSC1 Set communication to Module mode Starts the module and switches to AT mode

ESC Powering up modem...

ETRT? Query Reset Timer ESC, SMS Periodic reset timer: 1440min Time remaining: 1436min

ETSMSML=n Set SMS Max Limit, ETSMSML=n; n=number of SMS max limit before delete

ESC, SMS SMS Max limit set to: 50

ETHSD? Query Hash Send Delay Timer Periodic Hash send delay: xmin Time remaining: xxsek

ETHSD=n Set Hash Send Delay Timer, ETHSD=n; n=Delay Time in Minutes

ESC, SMS Periodic Hash send delay set to: 3min

Page 13: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 13 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

ET Command Description Command Method ESC (Serial in ESC Mode), SMS

Response

ETHSP? Query Hash Send Periodic Timer ESC, SMS Periodic Hash send timer: 10min Time remaining: 272s

ETHSP=n Set Hash Send Periodic Timer, ETHSP=n; n=Time in Minutes

ESC, SMS Periodic Hash send period set to: 10min

ETRT=n Set Reset Timer, ETRT=n; n=Time in seconds

ESC, SMS Periodic reset period set to: 0s

ETLGNR? Query Last Gasp report SMS Phonenumber. The phone number that the power failure SMS is sent to, default is ETM EWO i.e. 0709-032555026 (Infoflex number) ETLGNR? <CR>

ESC, SMS Last Gasp report number: +46709032555026

ETLGNR=XXXX XXX XXX

Set Last Gasp report SMS Phonenumber. ETLGNR=+46709032555026<CR>

ESC, SMS Last Gasp report number set to: +46709032555026

ETIPADD? Query IP Address and Port ESC, SMS IP address:Port: 000.77.219.177:8608 ETIPADD=n Set IP Address and Port ESC, SMS IP address:Port: set to: 000.77.219.177:8608 ETAPN? Query Network APN ESC, SMS APN: maingatelan.telia.se ETAPN=n Set Network APN ESC, SMS APN set to: maingatelan.telia.se ETLGPRT? Query Last Gasp Power return time.

Notification that power has returned after a power failure. A value between 0 -120 sec, the time that power needs to be present before a notification is sent. 0 = disabled.

ESC, SMS Last Gasp power return time: 120s

ETLGPRT=n Set Last Gasp Power return time, ETLGPRT=n; n=Time in seconds. Set ETLGPRT to a value between 0 – 120 seconds. 0 = disabled.

ESC, SMS Last Gasp power return time set to: 120s

ETLGPFT? Query Last Gasp power failure time. A value between 60-120 sec, the time that power needs to be absent in order for a power loss to be regarded as a power failure. 0 = disabled.

ESC, SMS Last Gasp power failure time: 120s

ETLGPFT=n Set Last Gasp power failure time, ETLGPFT=n; n=Time in seconds. Set ETLGPFT to a value between 60 – 120 seconds, Consider that the Meter needs x sec to start and power modem. 0 = disabled.

ESC, SMS Last Gasp power failure time set to: 120s

ETLGBT? Query Last Gasp block time. Block time is defined as the time in seconds which a power failure SMS will not be sent if a new power failure occurs. The functionality can be regarded as a basic hysteresis i.e. avoid unwanted rapid switching or in this case avoid several power failure SMS during a defined period

ESC, SMS Last Gasp block time: 3600s

ETLGBT=n Set Last Gasp block time, ETLGBT=n; n=Time in seconds. Set ETLGBT to a value between 0 – 43200 seconds (12 hours)

ESC, SMS Last Gasp block time set to: 3600s

ETHWS? Query Hardware serial number ESC, SMS Hardware serial: 71357 ETSWS? Query Software version ESC, SMS Software version: ETM Purple SW:2.2.9.24, SVN

version: TBD:TBD, Build time: Feb 1 2017 10:00:39

ETBSWS? Query Bootloader Software version ESC, SMS Bootloader Software version: 2.2.6.4 ETCC Clear SW-,PU-,PF-Counters ESC, SMS SW-,PU-,PF-,MR-Counter Cleared ETSEND="ATcmd" Send AT command to module ESC, SMS Response to AT command sent is forward to

serial port and/or SMS ETSJAM=n Send JAVA App cmds to the

Module, ETSJAM=n; n=cmd(0=install,1=start,2=stop,3=remove,4=list inst,5=list run)

ESC, SMS Sending command: “ETSJAM=5” ^SJAM: "a:/JRC-1.60.28.jad","Java Remote Control MIDlet Suite","Cinterion","1.60.28",1 ^SJAM: "a:/SocketTunnel_QS.jad","SocketTunnel_QS MIDlet Suite","ETM Matteknik AB, ETM Pacific and Tony Kay Pty Ltd","3.3.02770",1

ET&SR Do Software Reset on the MCU No response, unit will restart

ESC, SMS Shutting down modem... ^SHUTDOWN

Page 14: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 14 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Last Gasp Mode Operation Read ”ET&V” PROFILE by sending ET&V over SMS or serial port:

Example:

CID:001

LGNR:+46709032555026

IPADD:213.115.2.218:3003

APN:4g.tele2.se

HSD:3(min)

HSP:60(min)

LGPFT:60(s)

LGBT:60(s)

LGPRT:60(s)

RT:1440(min)

Max SMS limit:50

For Last Gasp operation, set:

[SMS] Set SMS phone number: ETLGNR=<SMS Phone number>

[TCP/IP] Set IP address and port: ETIPADD=<IP address>:<Port>

Note: If only “SMS”-Last Gasp is desired, set ETIPADD=000, to turn off TCP/IP operation.

Set APN: ETAPN=<apn>

Set Last Gasp Power failure time, ETLGPFT=n; n=Time in seconds

Set Last Gasp Block time, ETLGBT=n; n=Time in seconds

Set Last Gasp Power return time, ETLGPRT=n; n=Time in seconds

Example:

ETLGNR=+46709032555026

ETIPADD=213.115.2.218:3003

ETAPN=4g.tele2.se

ETLGPFT=60

ETLGBT=60

ETLGPRT=60

Last Gasp message protocol structure:

#9,Eventcode,ICC(SIMCno),Res,Res,Res,Res,RTC_Date,RTC_Clock,Alarm_counter(Power fail counter),I/O Alarm_Status(Event ID),Free_text,CapVolt,mV,IMEI,Modultemp

Note: “Res”=Reserved

Example:

#9,3,89462046211101409980,,,,,04/01/06,23:52:15+00,2,8AL,Power Failure,4.370,mV,004401081755155,24,

#9,4,89462046211101409980,,,,,04/01/07,00:00:49+00,3,8ALR,Power Restored,5.012,mV,004401081755155,25,

Page 15: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 15 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

AT Mode Operation In AT mode the Terminal can be controlled and by means of AT commands applicable to the Cinterion EHSx/ELS61 module, AT commands can be sent to either the serial or USB port. All commands must start with “AT” and end with Carriage Return (<CR> / ASCII 13).

Common useful AT commands for basic operation include: AT Command Description/Details Response Notes ATI Returns Module Name and Firmware

Version Cinterion EHS6 REVISION 03.001 OK

AT+CPIN=XXXX Allows you to input the SIM card PIN number, if required where XXXX is the PIN number

AT+CPIN? Check the PIN status +CPIN: READY OK

AT+CSQ returns signal strength e.g. CSQ 11,99 where 11 is the signal and 99 is the service quality

+CSQ: 11,99 OK

AT+CREG? Verifies network registration status, 0 – not registered, 1 – registered, 2 – not registered searching, 3 – registration denied, 5 – registered roaming

+CREG: 0,1 OK

AT+COPS? Indicates connected operator if applicable +COPS: 0,0,"vodafone AU",2 OK

AT&V will return the current settings for the terminal

ACTIVE PROFILE: E1 Q0 V1 X4 &C1 &D2 &S0 \Q3 S0:000 S3:013 S4:010 S5:008 S6:000 S7:060 S8:000 S10:002 +CBST: 7,0,1 +CRLP: 61,61,78,6 +CR: 0 +CRC: 0 +CMGF: 1 +CSDH: 0 +CNMI: 1,0,0,0,0 +CMEE: 0 +ICF: 3 +DTMF: 0 +CSMS: 0,1,1,1 +CREG: 0,1 +CLIP: 0,2 +COPS: 0,0,"vodafone AU",2 +CGSMS: 1 OK

AT&W Stores the current configuration of the unit. OK AT&F sets all current parameters to the

manufacturers default profile OK Caution this may adversely

affect the operation of the modem - contact ETM

AT^SCFG=“Radio/Band”,”X”

Sets available radio bands, we recommend using 511, all bands (where X=radio band setting)

^SCFG: "Radio/Band","511" OK

Page 16: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 16 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

SMS Specific Commands AT Command Description/Details Response Notes AT+CMGF=1 Changes the unit from PDU (Default Setting)

to text mode OK

AT+CSCA? Checks the SMS Central number Normally, this should be read automatically from the SIM Card at start-up

+CSCA: "+61415011501",145

AT+CMGS=“YYYYYYYYYY”

To send a SMS in Text Mode to a mobile number , where YYYYYYYYYY is the mobile phone number Next, wait for prompt >, then enter the text message followed by the CTRL and Z key together to send the message.

at+cmgs="0414532963" > test +CMGS: 112 OK

AT Commands for Incoming Circuit Switch Data Calls AT Command Description/Details Response Notes ATS0=2 Will set the unit to answer an incoming call

after 2 rings. Please note that for this to work the SIM Card must be provisioned with a Terminating Data Number by your network operator.

OK

AT+CRC=1 Sets call type indication, voice or incoming data call. Only terminating data calls displayed as REL ASYNC will be answered.

OK Note, this terminal does not have voice capabilities

JET Mode Operation Java ETM Terminal (JET) mode operation is controlled by Java™ code embedded within the BGS5, EHSx or ELS61 module designed to provide additional useful features such as TCP Threaded Tunnel mode Serial to TCP Tunnel etc. The JET mode, if installed, will typically run automatically but can be started and stopped by sending specific commands to the terminal. The specific operation of the JET mode can be tailored to meet customer requirements via the setting of various configuration options, these configuration options can be set, in most cases, via the serial port, by SMS or by TCP/IP. Some basic useful commands applicable to JET operations are shown below.

JET Command table The most common settings can be performed with the Windows based Configuration tool (CT) over the USB port. However, these settings and more can also be changed via SMS. Note that all settings must be saved with JETSAVE in order to be stored in persistent memory. The commands take effect immediately. Each JET set command answers with a response number see Jet configuration change response below.

Page 17: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 17 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

JET Command Description Command Method ESC(RS232 in ESC Mode), USB, SMS

Response example

JETI Query status Information. This information is shown in the CT “Real Time Status” tab.

USB, SMS TCPServerTesting,10/10/11,20160617,144630,3G,10638,-3.5,240,08,017C,0124B95,,TSIP:94.234.165.237:2055,TTTIP:94.234.165.237:2040,,3.3.02763,EHS5-E,2.0,15,12Kb,5Kb,Telenor SE,32,358173052048876,89460862917000109621,30,13,JET

ETSJAM=4 Requests details of JAD file currently installed

SMS If unit has JET functionality installed the file name will be similar to "a:/SocketTunnel_QS.jad","SocketTunnel_QS MIDIletSuite","ETM Matteknik AB","X.X.XX",X,XXXXX,XXXXXX Where X reflect the version of JET firmware

JETSEND=AT&V Will return the current settings for the modem.

USB, SMS JETSEND: ACTIVE PROFILE: E0 Q0 V1 X4 &C1 &D2 &S0 \Q3 S0:000 S3:013 S4:010 S5:008 S6:000 S7:060 S8:000 S10:002 +CBST: 7,0,1 +CRLP: 61,61,78,6 +CR: 0 +CRC: 0 +CMGF: 1 +CSDH: 0 +CNMI: 1,0,0,0,0 +CMEE: 0 +ICF: 3 +DTMF: 0 +CSMS: 0,1,1,1 +CREG: 0,1 +CLIP: 0,2 +COPS: 0,0,"00540065006C0065006E006F0072002000530045",2 +CGSMS: 1 OK

JETCPIN=n Set SIM pin; n=SIM pin USB, SMS JETCPIN=2009(2) JETTHREADEDTUNNEL TCPINUSE=n

Turn on/off the Threaded Tunnel function: n=false for OFF n=true for ON

USB, SMS JETTHREADEDTUNNELTCPINUSE=true(2)

JETTHREADEDTUNNEL TCPSERVERAPN=n

Set Threaded Tunnel APN; n=APN name

USB, SMS JETTHREADEDTUNNELTCPSERVERAPN =static.telenor.se(13)

JETTHREADEDTUNNEL TCPSERVERUSERNAME =n

Set Threaded Tunnel User Name; n=user name

USB, SMS JETTHREADEDTUNNELTCPSERVERUSERNAME=user(11)

JETTHREADEDTUNNEL TCPSERVERPASSWORD =n

Set Threaded Tunnel Password; n=Password

USB, SMS JETTHREADEDTUNNELTCPSERVERPASSWORD=password(11)

JETTHREADEDTUNNEL TCPSERVERLOCALPORT =n

Set TCP/IP Port; n=Port number USB, SMS JETTHREADEDTUNNELTCPSERVERLOCALPORT=4059(2)

JETTHREADEDTUNNEL SERIALCOMSPEED =n

Set Serial port speed; n=baudrate USB, SMS JETTHREADEDTUNNELSERIALCOMSPEED =9600(2)

JETTHREADEDTUNNEL SERIALQUIETDELAY=n

Set delay time to send data; n=delay time in ms

USB, SMS JETTHREADEDTUNNELSERIALQUIETDELAY =250(2)

JETPINGERINUSE=n Turn on/off the pinger function. n=false for OFF n=true for ON

USB, SMS JETPINGERINUSE=true(2)

JETPINGERIP=n Set the ping IP server address. n=IP address in format xxx.xxx.xxx.xxx DNS address is not acceptable.

USB, SMS JETPINGERIP=192.168.010.001(2)

JETPINGERSCHEDULED INTERVAL=n

Ping interval in minutes. n=interval in minutes

USB, SMS JETPINGERSCHEDULEDINTERVAL=5(2)

JETPINGERTRIGGER COUNT=n

After n failed Ping attempts disconnect from carrier and reconnect. n=number of failed Ping attempts.

USB, SMS JETPINGERTRIGGERCOUNT=5(2)

JETSAVE Saves changes to memory done with JET commands.

USB, SMS JETSAVE (OK)

Page 18: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 18 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

JET Configuration change responses When changing options within the JET code, by any connection method, JET responds with a completion method response number;

DataSet: 13 – An existing entry key is available and the value is not the same as the data being set 11 – There is no existing entry key available so the new entry was created 2 – An existing entry key is available and the value is the same as the data being set 0 – The entry key being used is null and is not being set

DataSetCaseSensitive: 111 – The entry was set 0 – The entry key being used is null and is not being set

DataUnset: 12 – The entry was removed 1 – The entry either did not exist to be removed or there was an error

DataUnsetCaseSensitive: 12 – The entry was removed 1 – The entry either did not exist to be removed or there was an error ... so when setting or deleting an option a return value greater than 0 is a good response.

Page 19: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 19 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Installing the configuration tool in Windows 7. • Contact ETM to get the ETM-Purple Configuration Tool (PCT).

• Save the driver software to a local place on the computer.

• Connect the ETM-Purple to the computer with a USB cable with USB Type A connector in one end and USB Mini-B in the other end.

Figure 6. USB driver installation.

• The computer will try to install the USB drivers, see figure 6. Click on the pop up window in order to see the status information.

Page 20: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 20 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 7. USB driver installation, skip automatic search.

• Click on the row “Skip obtaining driver software from Windows Update”, see figure 7.

* Note: Actual port number will vary depending on USB port used.

Page 21: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 21 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 8. USB driver installation, browse manually.

• Click on the alternative “Browser my computer for driver software”, see Figure 8.

Page 22: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 22 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 9. USB driver installation, find the driver locally.

• Browse to the saved folder for the ETM-Purple Configuration Tool and select the folder ehsx_drivers_1113/usb and click OK, see figure 9 Note: You need to be logged in as Admin user on the computer in order to get permission to install the driver.

Page 23: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 23 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 10. USB driver installation, find the driver locally.

• Click on the “Install” button, see figure 10.

Page 24: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 24 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 11. USB driver installation, check the installation.

• Check in the “Control Panel”/”Device Manager” that “Cinterion EHx USB Com Port number 1 to 6 is installed, see figure 11. If this is not the case, right click on the failing one and select “Update driver software” and follow the instructions.

*Note: it is irrelevant if “Cinterion do_not_use” port is not installed. This does not affect the operation.

• Open the program "Purple Config Tool.exe" in the locally stored folder.

• Install .NET if you are asked to do that.

Page 25: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 25 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Local configuration The most common settings can be performed with the Windows based ETM-Purple Configuration Tool (PCT) over the USB port. The below instruction will only cover the basics of all available settings.

Note: Make sure there is SIM card in the modem.

To configure the ETM-Purple locally, a USB-A to a USB-mini-B cable must be available. This ETM programming kit connects a Windows computer with the ETM-Purple modem without using a mobile network. The advantages include:

• the user can see the modem during the configuration

• only a single user needs to know how to configure the modems

The followings steps describe how the modems can be configured once the ETM configuration software has been installed on a Windows XP, Windows 7 or Windows 10 computer:

1. Connect the USB cable to the ETM-Purple modem.

2. Make sure that a SIM card is installed

3. Connect the USB cable to the Windows computer

4. Start the Purple Configuration Tool software tool on your computer. It should look like figure 13, otherwise select the "User Settings (JET Commands):

Figure 13, screen showing “not connected” modem.

Page 26: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 26 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

5. Select the modem type (2G, 3G or 4G) in the top left drop down list.

6. Click on Connect modem on the top tab row.

*Note: Make sure that the “Devices found: 2” is displayed. If its not 2, there is a problem with the USB driver.

The “Port status” shall change to open and the fields will be populated, see figure 14.

Note: If the field isn’t automatically populated, click on the “Read setting” button at the lower left corner.

Figure 14, screen showing “connected” modem and populated fields.

Quality of service parameter sending (#1 sending) 7. Make the following settings if the quality of service parameter

sending functionality will be used: – Select the tab “Hash sending”, se figure 15. – Set “Hash TCP in use” to True. – Set “send interval (min)” to 60 if you want the modem to send the

quality of service package every hour. – Enter "IP" to the EWO server or other type of receiving server – Enter “remote port” for the EWO server or other type of receiving

server – Set APN

Page 27: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 27 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

– Enter "User Name" and "Password" for the ISP, if needed. – Set “User ID use CCID” to TRUE in the “Global” tab, see figure

16.

Click WRITE AND SAVE SETTINGS. The changed data will be written into the memory of the ETM-Purple modem.

Figure 15, screen showing “connected” modem and populated fields.

Page 28: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 28 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 16, screen showing “connected” modem and populated fields.

Threaded Tunnel settings 8. Make the following settings if the “Threaded Tunnel” functionality

will be used: – Select the tab “Threaded Tunnel”, se figure 17. – Set “Server in use” to True. – Set APN – Enter "User Name" and "Password" for the ISP, if needed. – Enter the TCP/IP port number for the modem in the “TTServer

local port” box. – Set serial port baud rate in the “Configuration” tab, see figure 14. – Enter SIM pin in the “Global” tab and “CPIN” box if needed, see

figure 16. Click WRITE AND SAVE SETTINGS. The changed data will be written into the memory of the ETM-Purple modem.

Page 29: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 29 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 17, screen showing the “Threaded Tunnel” settings.

Page 30: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 30 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

9. Select the “Real Time Status” tab. The following screen will appear:

Figure 18, screen showing “Real Time Status”.

The “Real Time Status” screen shows useful information about the mobile network, software, hardware and data-exchange parameters. This screen is updated every 15 seconds which is adjustable.

These parameters can be saved to the local computer by pressing the “Save RTS Report”.

Page 31: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 31 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

10. Select the “Terminal” tab. The following screen will appear:

Figure 19, screen showing the “Terminal” window.

In the Terminal window the user can send single commands starting with JET, see JET command table above.

Page 32: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 32 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

11. Select the “Debug Terminal” tab. The following screen will appear:

Figure 20, screen showing the “Debug Terminal” window.

This screen shows the activity in the modem and can be useful to fault trace problems in the field. The debug log shows activity since the start of the ETM-Purple Configuration Tool. The log file can be saved to the local computer by pressing the “Save” button.

Page 33: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 33 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

12. Select the “COM Connection/settings” tab. The following screen will appear

Figure 21, screen showing the “COM Connection” window.

The USB port settings and the ETM-Purple Configuration Tool password can be changed in this screen.

Note that the modem connection to the computer can stop working if changes are made in this screen.

Page 34: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 34 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

Figure 22, screen showing the “File” menu.

13. Select “Read & Save Script file from Modem” to save the complete modem configuration for backup or in order to copy the configuration to other ETM-Purple modems.

14. Select “Load & Execute Script file to configure Modem” to open a saved modem configuration and load it to the modem.

15. Disconnect the modem by clicking on the “Disconnect Modem”.

* Always disconnect before unplugging otherwise the device may not be recognized or port may be stuck.

16. Unplug the ETM programming USB cable from the ETM-Purple modem and computer.

Page 35: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

Page 35 of 36 For Support Contact +46 25 28 75 or [email protected]

1802-20170003 07 ETM Purple user guide.docx

This page intentionally left blank

Page 36: Intelligent Tri-Mode Terminal – ETM Purple€¦ · PLC, PC or Server . Page 4 of 36 For Support Contact +46 25 28 75 or sales@etm.se 1802-20170003 07 ETM Purple user guide.docx

ETM Matteknik AB Ekbacksvägen 32 SE-168 69 Bromma Sweden Tel: +46 (0)8 25 28 75 Fax: +46 (0)8 80 11 10 Email: [email protected] Web: www.etm.se

ETM Pacific Pty Ltd Suite, 273 Alfred Street North Sydney NSW 2060 Australia Tel: +61 (0)2 9956 7377 Fax: +61 (0)2 9956 5791 Email: [email protected] Web: www.etmpacific.com.au

© ETM Pacific Pty Ltd · Subject to change without notice.