47
“Integrated Functional- Aesthetic - Restorative, Prosthodontic & Implant Dentistry” Dr. Samuel Waknine, M.D.M.S., Ph.D.

“Integrated Functional-Aesthetic - Restorative, Prosthodontic & Implant Dentistry” Dr. Samuel Waknine, M.D.M.S., Ph.D

Embed Size (px)

Citation preview

“Integrated Functional-Aesthetic -

Restorative, Prosthodontic & Implant Dentistry”

Dr. Samuel Waknine, M.D.M.S., Ph.D.

DiamondCrown

Case no 1

Direct Restoration of a Traumatized Lateral Incisor

6 Years Post-Op.

TM

DiamondCrownAlloyless, Fiberless

Case no 2Anterior Crowns

(7 years Post-Op.)

TM

DiamondCrownAlloyless, Fiberless

Case no 3Anterior Crowns

(7 years Post-Op.)

TM

Emilio balbo

DiamondCrown

Case no 4

3-Unit Posterior Bridgework Alloyless, Fiberless

TM

Clinical Implications 1 Average Human Masticatory ForceAnterior - 9 MPa

Posterior - 31 - 41 MPa

Moler Flexural Strength - (fracture) - 145 MPa

1 Kg /mm2 = 10 N/mn2 = 1 MPa = 145 psi

DiamondCrown

x 9Diametral Tensile Strength - 79 MPax 2.2

Biaxial Flexural Strength - 231 Mpax 1.6

TM

DiamondCrown

Case no 5

Posterior Crown & BridgeAlloyless, Fiberless

(5 years Post-op)

TM

DiamondCrown

Case no. 6

Long-Span Alloy-Based Framework

(5 years Post-op)

TM

“Tissue Compatible

Bio-Integrated Functional-Esthetic -

Implant Prosthodontics

Dr. Samuel Waknine, M.D.M.S., Ph.D.

DiamondCrown Conventional Ti-Implant Superstructure

(7 years Post-Op.)

TM

Case no. 7

Integrated

Implant Post - ZTi

Superstructure - DiamondCrown

TM

TM

IDC+ZTi™

DiamondCrown IDC StratificationDiamondCrown IDC StratificationTM

DC Metal Cupler / Opaque

ZTiImplant

Post

ZTi Abutment Post

DC Opaque Dentin

DC Dentin

DC Enamel

DC Incisal

Clinical Implications 2

1 Kg /mm2 = 10 N/mn2 = 1 MPa = 145 psi

Biomechanical Concepts

Porcelain Fused to MetalShear Bond Strength - 12 MPa

DiamondCrown IDC - Abutment Post Shear Bond Strenght - 35 MPa

(x 3)

TM

IDC-Abutment-Implant Cross-Section

Metal Opaque

Opaque-Dentin

Dentin

Enamel

DiamondCrown IDC Accelerated Cyclic Fatigue Studies

(3 years In-Vivo Correlation)

TM

Clinical Implications 3

Average Human Masticatory ForceAnterior - 9 MPaPosterior - 31 MPaBruxer - 41 MPaPistachio Sealed Shell - 16 MPa

1 Kg /mm2 = 9.807 N/mn2 = 1 MPa = 145 psi

IDC (Molar) - 500 MPa (3000N/6mm2)

Biomechanical Concepts

x55x16x12x31

DiamondCrown™ Implant-Superstructure(s) IDC Clinical

Application5-Year Post-Op.

Case no. 8

Biocompatibility

A Novel Polycrystalline Reinforced Superstructure for Aesthetic - Restorative - Prosthodontic & Implant

Dentistry

DiamondBond-001 - DiamondFlow - DiamondLite -DiamondLink & DiamondCrown™

Dr. Samuel Waknine, M(D.M.S.), Ph.D.

New York University College of DentistryDRM Research Laboratories, Inc. USA