36
i700 & i702 Professional Steam Boiler i700A/B & i702C Professional Steam Cleaner Instruction Manual

Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700 & i702 Professional Steam Boiler

i700A/B & i702C Professional Steam Cleaner

Instruction Manual

Page 2: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the
Page 3: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the instructions carefully. With proper care and maintenance, your steamer will provide years of dependable service. Your boiler is supplied with a safety cap on the blow-down valve (right side of tank), as well as a plastic tube and fitting to secure the tube. Please remove the safety cap and install the tube and fitting. This will allow you to follow the cleaning procedure described at the bottom of the page. If there is a problem with the blow-down valve (leaking) you can use the safety cap to prevent water from leaking until you have the valve replaced.

1. Remove the steam generator from its packing and make sure all packing parts have been taken off (including the protective bags). Lay the machine on a flat and solid surface fitted to support it next to a wall socket (max. mt. 1,5).

2. Connect the accessory’s plug (iron i30, steam brush i38) to the socket (7) and the accessory’s steam hose to its brass “L” connector (8). Repeat the same operation with the second socket and the second “L” connector (8) (For mod. i702 only).

3. Before beginning any operation, make sure that the exhaust valve (10) is closed and the “L” joint is screwed with the outlet downwards.

4. Unscrew the safety cap (1) and fill the boiler with max. 7L tap water being careful not to overfill it. Screw the safety cap (1) snug only.

5. Insert the electrical plug (5), press the boiler switch on (3) and the steam switch on (2). When the two switches come on, the generator is working.

6. Set the temperature regulation knob (14) on the iron to “cotton ooo

”. 7. Keep waiting for the manometer (12) indicating 3,5 bar (it takes

about 20/25 minutes) 8. The machine is ready for use. 9. Press the steam button (13) of the steam iron (9) or steam brush

(11). It is possible to regulate the steam quantity by the steam regulation knob (6).

10. In case the steam stops during ironing and the water button’s red light (4) comes on, it means that there is not enough water in the tank. To start ironing again, switch off the boiler button (4); press the steam iron button (13) to ensure there is no more steam in the boiler, slowly open the pressure cap (1) and refill to the required level with warm water. Replace the cap and wait for it to build up pressure again.

11. When you first press the steam button (after having turned the boiler on and depressed the steam button (13) on the iron you might notice

Page 4: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

a decrease in pressure. This is because the tank has air in it. In order to have plenty of steam (after you have depressed the iron) wait until the pressure goes back up to the maximum level before you begin.

Picture 1. Mod. i700 Picture 1. Mod. i700 + i30 COMPONENTS 1. Safety cap 2. Steam switch 3. Boiler switch 4. Low water red pilot light 5. Power cord and plug 6. Steam regulation knob 7. Plug for accessory and solenoid valve control 8. “L” connector for steam outlet 9. Steam iron (i30 see mod. i700 + i30) 10. Exhaust valve 11. Steam brush (i38 see mod. i702 + i30 + i38) 12. Manometer 13. Steam button 14. Temperature regulation knob (i30)

Page 5: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

Picture 1. Mod. i702 Picture 1. Mod. i702 + i30 + i38 COMPONENTS 1. Safety cap 2. Steam switch 3. Boiler switch 4. Low water red pilot light 5. Power cord and plug 6. Steam regulation knob 7. Plug for accessory and solenoid valve control 8. “L” connector for steam outlet 9. Steam iron (i30 see mod. i700 + i30) 10. Exhaust valve 11. Steam brush (i38 see mod. i702 + i30 + i38) 12. Manometer 13. Steam button 14. Temperature regulation knob (i30)

Page 6: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

CAUTION

• Do not leave the machine unattended while the plug is connected to the socket

• Avoid opening the exhaust valve (10) while the machine is working, connected to the electric outlet or while it is still under pressure.

• Clean the boiler by opening the exhaust valve (10), only when the machine has been disconnected from the electrical outlet (for safety). For best performance, clean the boiler after every use.

• For complete safety, before refilling the boiler, please disconnect the plug.

• Do not touch the iron plate while ironing and for 15 minutes after it is switched off.

• While using the machine, never unscrew or remove the cap while under pressure. Before removing it, make sure that it does not give off steam anymore by shutting the boiler off, and pressing the steam iron button (13) to release all remaining steam.

• The safety cap (1) must be replaced with original parts only. TECHNICAL DATA Working voltage: 120V (i700+i702C) 220V (i702) Nominal capacity of the tank: 9 Liters Boiler power: 1 heating element 1200W (i700+i702C) and 2 heating elements 800W (i702) Power consumption: 20 amps (i700) Service pressure: 3,5 Bar/4 Bar Maximum pressure: 7 Bar

Page 7: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

TROUBLESHOOTING

PROBLEM EXPLANATION SOLUTION

Does steam go

out from the boiler?

It may happen that, while filling the tank, some water overfills the cap

and flows inside the boiler wetting the insulating material

In order to solve the problem, we suggest using the machine as usual so that the

insulating material dries up in about one hour through the heat of the machine. In case you still have this problem after one

working hour, please contact the service centre.

Does the

steam iron leak steam mixed with

water?

1) While filling the tank you may

have poured too much water into it.

2) The iron plate has to be hot before the steam passage

1) The problem will go on until the excess

water is emptied. Keep the steam button depressed until the water in the tank is at the correct level.

2) Please check that the temperature knob is on the right position: “cotton °°°)”

There is

no steam coming out of the

iron?

1) The steam knob (where

supplied) might be closed 2) The iron switch might be off

3) The boiler switch might be off 4) The water might be used up.

1) Open the steam knob anticlockwise.

2) After the iron switch comes on, wait for 4 minutes so that the iron plate gets hot.

3) After the boiler switch comes on, wait for 10 minutes so the boiler produces steam. 4) Fill it following the instructions carefully.

Does the ironing board get

wet?

1) The ironing board cover might not be able to absorb the steam completely

2) The steam iron leaks steam mixed with water (Check by spraying some steam on a dry

cloth)

1) You might use a thicker cover (or two covers) so to create a thicker surface to absorb the steam better. In case you are

using a vacuum table, switch on the vacuum function each time you are using the steam

2) See # 2

Does the steam leak

dirty water?

Some dirty might have gone into the tank with the water and it is

given off from the iron.

Fill the empty tank with 1 liter of water, screw the cap up, shake it, unscrew the

cap and empty the tank. Repeat the action until the water is cleaned. We do not recommend the use of any additive to pour

in the tank. Before ironing again spray some steam on a cloth until clean steam comes out.

Page 8: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700 SPARE PARTS LIST

ITEM DESCRIPTION U.M Q.TY

AST113 FLAT WASHER FOR PA012 NR 2

CD024/442 NIPPLE JOINT NR 1

CD332 HANDLE FOR MOD.07/08/09 NR 1

CD332/2 HEXAGONAL HEADED SCREW NR 2

CD338/1 STICK SUPPORT NUT NR 1

CD338/2 WASHER FOR STICK SUPPORT NR 3

CD338/3 STICK SUPPORT NR 1

CD347 FAIRLEAD FOR CAP JOINT NR 1

CD347/7000 FAIRLEAD FOR SOLENOID VALVE NR 1

CD348/1 SCREW FOR BULB THERMOSTAT NR 6

CD348/185 BULB THERMOSTAT 165° NR 2

CD350 RED LIGHT 110V UL APPROVAL NR 1

CD351 CONNECTOR FOR SOLENOID VALVE NR 1

CD360 STOP FOR FAIRLEAD 6W-1 NR 1

CD361 STOP FOR FAIRLEAD 6N 3-4 NR 1

CD365/5 SAFETY CAP WITH TEFLON O-RING NR 1

CD366/6 O-RING FOR SAFETY CAP NR 1

CD367 DYN FOOT NR 4

CD368 WAND NR 1

CD369 FUNNEL NR 1

GV028/84/110 ADJUSTABLE SOLEINOID VALVE NR 1

CD374/1 MANOMETER NR 1

CD458 TECHNICAL DATA NR 2

CV103 METAL RING 1/4 SOLENOID NUT 7000 NR 1

FS012 SCREW M4x22 FOR THERMOSTAT FIXING NR 5

FS017 STAINLESS HANDLE FIXING SCREW M5x10 NR 2

GV025/15 PTFE O-RING FOR HEATING ELEMENT NR 2

Page 9: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION U.M Q.TY

GV025/23 WHITE ZINC-PLATED NUT 4MA 5588 NR 6

GV025/27 NUT NR 2

GV025/30 NUT NR 9

GV025/31 SCREW NR 3

GV025/32 NUT NR 2

GV025/33 NUT NR 1

GV025/45 GLASS LEVEL NR 1

GV025/47 NUT NR 9

GV025/49 COVER FOR GLASS LEVEL INDICATOR NR 1

GV025/51 COPPER PIPE NR 1

GV025/55 SCREW FOR GLASS FIXING 3 MA NR 2

GV025/56 NUT FOR TAP NR 1

GV026/12 TAP NR 1

GV026/7 FEMALE FAST RECEPTACLE NR 1

GV028/1/110 INCOLOY HEATING ELEMENT 1200W 110V NR 2

GV028/12 "L" JOINT FOR COCK NR 2

GV028/15 BASEMENT NR 1

GV028/17 VARNISHED IRON HOLDER NR 1

GV028/18 BRACKET BOILER FIXING NR 1

GV028/19 GLASS FIXING PLAQUE NR 2

GV028/2 STAINLESS BOILER NR 1

GV028/22 CHOCK FOR TAP NR 1

GV028/27 EXTESION JOINT NR 1

GV028/29 BOILER INSULATING FOR ITEM I700N NR 1

GV028/30 "L" JOINT FOR SOLENOID VALVE NR 1

GV028/33 O-RING FOR GLASS LEVEL NR 2

GV028/36 FEMALE FRUIT ILME PLUG NR 1

GV028/43 JOINT FOR TEDDINGTON NR 1

GV028/45 STRAIGHT HOLDER WITH ROD NR 1

Page 10: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION U.M Q.TY

GV028/46 TEDDINGTON PRESSURE SWITCH NR 1

GV028/47 WIRING FOR I700N/110V 1,5 MM NR 1

GV028/49 CHASSIS NR 1

GV028/50 FRONT CHASSIS NR 1

GV028/52 SCREW NR 4

GV028/6 YELLOW BRASS ANGLE CONNECTION NR 1

GV028/69 BOX NR 1

GV028/72 TUBE NR 1

GV028/73 ANGLE CONNECTION NR 1

GV028/74 POWER CORD NR 1

GV028/75 HOSE CLAMP NR 1

GV028/76 MANUAL INSTRUCTION NR 1

GV028/9 SCREW FOR CLOSING NR 16

GV029/4 COVER NR 1

MC020 BIPOLAR SWITCH NR/NR+ LED RED NR 2

RIC003/2 CERAMIC TERMINAL BLOCK FOR 110V NR 1

Page 11: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700/120V PARTS DRAWING

Page 12: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700 WIRING DIAGRAM

Page 13: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i702 SPARE PARTS LIST

ITEM DESCRIPTION UM Q.TY

AST113 FLAT WASHER NR 2

CD024/442 BRASS NIPLE JOINT NR 1

CD332 HANDLE FOR NR 1

CD332/2 HEXAGONAL HEADED SCREW NR 2

CD338/1 STICK SUPPORT NUT NR 2

CD338/2 WASHER FOR STICK SUPPORT NR 4

CD338/3 STICK SUPPORT NR 2

CD347 FAIRLEAD FOR CAP JOINT NR 1

CD347/7000 FAIRLEAD FOR SOLENOID VALVE NR 1

CD348/1 SCREW FOR BULB THERMOSTAT NR 6

CD348/185 BULB THERMOSTAT 165° NR 2

CD350 RED LIGHT 110V UL APPROVAL NR 1

CD351 CONNECTOR FOR SOLENOID VALVE NR 2

CD360 STOP FOR FAIRLEAD 6W-1 NR 2

CD361 STOP FOR FAIRLEAD 6N 3-4 NR 1

CD365/5 SAFETY CAP WITH TEFLON O-RING NR 1

CD366/6 O-RING FOR SAFETY CAP

CD367 DYN FOOT NR 4

CD368 STICK TO HOLD THE CORD UP NR 2

CD369 FUNNEL D. 10 ITEM 013 NR 1

GV028/84 ADJUSTABLE SOLENOID VALVE NR 2

CD374/1 GAUGE SCALE 0/10 NR 1

CD458 TECNICAL DATA NR 2

CV103 METAL RING 1/4 SOLENOID NUT 7000 NR 1

FS012 SCREW M4x22 FOR THERMOSTAT FIXING NR 5

GV025/15 PTFE O-RING FOR HEATING ELEMENT NR 2

GV025/19 "T" JOINT 1/4F NR 1

GV025/20 BEND JOINT M-M NR 2

GV025/23 WHITE ZINC-PLATED NUT 4MA 5588 NR 8

GV025/27 NOTCHED WASHER FOR FOOT NR 2

GV025/30 NUT 3MA NR 8

GV025/31 SCREW 3MA NR 5

Page 14: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV025/32 NUT FOR WATER LEVEL INDICATOR 3/8 NR 2

GV025/33 NUT FOR WATER LEVEL INDICATOR JOINT NR 1

GV025/45 WATER LEVEL INDICATOR NR 1

GV025/47 WASHER FOR SCREW DIAM. 3 NR 8

GV025/49 GLASS PLATE NR 1

GV025/51 COPPER HOSE NR 1

GV025/55 SCREW FOR GLASS FIXING 3 MA NR 2

GV025/56 CLOSING NUT NR 1

GV026/12 FAIRLEAD NR 1

GV026/7 FEMALE FAST RECEPTACLE NR 2

GV028/1 INCOLOY HEATING ELEMENT 800W 230V NR 2

GV028/12 "L" JOINT FOR COCK NR 2

GV028/15 BASEMENT NR 1

GV028/16 TOP NR 1

GV028/18 BRACKET BOILER FIXING NR 1

GV028/19 GLASS FIXING PLAQUE NR 2

GV028/2 STAINLESS BOILER NR 1

GV028/22 CHOCK FOR COCK NR 1

GV028/27 EXTESION JOINT NR 1

GV028/29 BOILER INSULATING NR 1

GV028/30 "L" JOINT FOR SOLENOID VALVE NR 1

GV028/33 O-RING FOR GLASS LEVEL NR 2

GV028/35 CORD 3,5 MT NR 1

GV028/36 FEMALE FRUIT ILME PLUG NR 2

GV028/43 JOINT WITH OGIVA FOR SOLENOID NR 1

GV028/45 STRAIGHT HOLDER WITH ROD NR 2

GV028/46 TEDDINGTON PRESSURE SWITCH NR 1

GV028/47 WIRING FOR I700N/110V 1,5 MM NR 1

GV028/49 CHASSIS NR 1

GV028/50 FRONT CHASSIS NR 1

GV028/52 SCREW NR 4

GV028/6 "L" JOINT DA1/4 MALE/FEMALE NR 2

GV028/70 BOX NR 1

Page 15: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV028/72 PVC TUBE FOR WATER DISCHARGE NR 1

GV028/73 ANGLE CONNECTION NR 1

GV028/75 HASE CLAMP NR 1

GV028/76 MANUAL INSTRUCTION NR 1

GV028/9 SCREW FOR CLOSING NR 16

MC020 BIPOLAR SWITCH NR/NR+ LED RED NR 3

RIC003/2 CERAMIC TERMINAL BLOCK FOR 110V NR 1

Page 16: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i702 PARTS DRAWING

Page 17: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i702 WIRING DIAGRAM

Page 18: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

USER INSTRUCTIONS i700A/B & i702C Thank you for purchasing the Reliable™ i700A/B or i702C series steam cleaner. Please follow the instructions carefully. With proper care and maintenance, your steamer will provide years of dependable service. Your steamer is supplied with a safety cap on the blow-down valve (right side of tank), as well as a plastic tube and fitting to secure the tube. Please remove the safety cap and install the tube and fitting. This will allow you to follow the cleaning procedure described at the bottom of the page. If there is a problem with the blow-down valve (leaking) you can use the safety cap to prevent water from leaking until you have the valve replaced. 1. Unscrew the security cap (on the top) and fill the steamer with a

maximum of 7 liters of water. For the i700A or i702C screw in the adjustable nozzle and tighten securely. Insert the 4-pin receptacle provided for the plug on the electronic foot pedal. For the i700B or i702C, connect the steam gun by plugging it in the quick disconnect fitting on the solenoid valve (you can also install the hose support wand at this time as well) and insert the 4-pin connector in the receptacle provided.

2. Plug the steam generator into the main power supply. 3. Switch on the steam generator by pressing the button "boiler" and the

steam by pressing the “steam “ button. 4. Wait until the pressure reaches 4-5 bar (60-70 lbs) (about 15 min.). 5. Press the foot pedal or the (red) steam button on the steam gun and

regulate the desired steam quantity by turning the valve handle situated behind the solenoid valve on the steam generator.

6. Every 30 minutes check the water level in the glass to ensure that the

water is not below the minimum level mark. If you notice a decrease in steam pressure when you first use the steamer, this is because the tank is full of air. In order to have plenty of steam (after you have depressed the foot pedal or steam gun) wait until the pressure goes back up to the maximum level before you begin. If during use the steam flow ceases and the low water button lights up, it means that there's no more water in the steam generator. In order to start steaming again, switch off the "boiler" button, slowly unscrew the security

Page 19: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

cap, verifying before unscrewing it completely that there is no more steam in the nozzle or steam gun. To verify this, just press the foot pedal or the red steam button situated on the gun. Take the plug off the steam generator and fill the steamer with water to the required level. i700A/B & i702C COMPONENTS

Picture 1. Mod. i700A Picture 1. Mod. i700B

COMPONENTS i700A/B & i702C 1. Safety cap 2. Steam switch 3. Boiler switch 4. Low water red pilot light 5. Power cord and plug 6. Steam regulation knob 7. Plug for accessory and solenoid valve control 8. Adjustable steam nozzle (i700A-i702C) 9. Steam tip (i700A+i700B-i702C) 10. Exhaust valve 11. Pedal (i700A-i702C) 12. Manometer 13. Steam gun (i700B-i702C) 14. Steam switch (i700B-i702C

Page 20: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

Picture 1. Mod. i702C

COMPONENTS i700A/B & i702C 1. Safety cap 2. Steam switch 3. Boiler switch 4. Low water red pilot light 5. Power cord and plug 6. Steam regulation knob 7. Plug for accessory and solenoid valve control 8. Adjustable steam nozzle (i700A-i702C) 9. Steam tip (i700A+i700B-i702C) 10. Exhaust valve 11. Pedal (i700A-i702C) 12. Manometer 13. Steam gun (i700B-i702C) 14. Steam switch (i700B-i702C)

Page 21: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

CAUTION

1. Never leave the machine unattended when it's plugged in. 2. Never remove the tank locking cap while the machine is running and

always check, before removing it, that no steam is coming out of the iron.

3. The tank-locking cap must be replaced with original spare parts. DO NOT TIGHTEN THE CAP TOO MUCH AS IT WILL CAUSE THE PLASTIC TO CRACK. MAKE SURE IT IS "SNUG".

4. For a longer life and better machine performance, we suggest you to rinse (blow-down) the tank once a day using the valve on the side of the steamer. Check that no more steam comes out of the nozzle or gun before you open the valve. Let all of the water flow out of the steamer into a bucket (not supplied), and then close the valve.

5. The use of normal tap water is recommended for the i700A/B & i702C.

6. Make sure you refill the steamer before you turn it back on. 7. The warranty does not cover mineral damages due to not cleaning

the steamer. 8. Service: If you need to have this product serviced, please contact

only authorized technical assistance centers (for further information please call 1-800-268-1649 or visit our web site at www.reliablecorporation.com).

TECHNICAL DATA Working voltage: 120V (i700A-B-i702C) Nominal capacity of the tank: 9 Liters Boiler power: 1 heating element 1200W (i700A-B-i702C) Power consumption: 15 amps (i700S-B- i702C) Service pressure: 3,5 Bar/4 Bar Maximum pressure: 5,5 Bar

Page 22: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

TROUBLESHOOTING PROBLEM EXPLANATION SOLUTION

Does steam go out from

the boiler?

It may happen that, while filling the tank, some water overfills the cap and flows inside the boiler wetting

the insulating material.

In order to solve the problem, we suggest using the machine as usual so that the insulating material dries up in about one

hour through the heat of the machine. In case you still have this problem after one working hour, please contact the service

centre.

Does the nozzle or

gun leak water mixed with

steam?

1) While filling the tank you may have poured too much water into it.

1) The problem will go on until the excess water is emptied. Keep the steam button

depressed until the water in the tank is at the correct level.

There is no steam

coming out of the nozzle or

gun?

1) The steam knob (where supplied) might be closed.

2) The foot pedal is not plugged in (i700A or i702C) 3) The boiler switch might be off.

4) The water might be used up.

1) Open the steam knob anticlockwise.

2) Plug the 4-pin receptacle into the boiler. 3) After the boiler switch comes on, wait for

10 minutes so the boiler produces steam. 4) Fill it following the instructions carefully.

Does the steam leak dirty

water?

Some dirty might have gone into the tank with the water and it is given off from the iron.

Fill the empty tank with 1 liter of water, screw the cap up, shake it, unscrew the cap and empty the tank. Repeat the action

until the water is cleaned. We do not recommend the use of any additive to pour in the tank. Before ironing again spray some steam on a cloth until clean steam

comes out.

Page 23: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700A SPARE PARTS LIST

ITEM DESCRIPTION UM Q.ty

AST113 FLAT WASHER FOR PA012 NR 2

CD024/442 NIPPLE JOINT NR 1

CD332 HANDLE FOR MOD.07/08/09 NR 1

CD332/2 HEXAGONAL HEADED SCREW NR 2

CD338/1 STICK SUPPORT NUT NR 1

CD338/2 WASHER FOR STICK SUPPORT NR 3

CD338/3 STICK SUPPORT NR 1

CD347 FAIRLEAD FOR CAP JOINT NR 1

CD347/7000 FAIRLEAD FOR SOLENOID VALVE NR 1

CD348/1 SCREW FOR BULB THERMOSTAT NR 6

CD348/185 BULB THERMOSTAT 165° NR 2

CD350 RED LIGHT 110V UL APPROVAL NR 1

CD351 CONNECTOR FOR SOLENOID VALVE NR 1

CD360 STOP FOR FAIRLEAD 6W-1 NR 1

CD361 STOP FOR FAIRLEAD 6N 3-4 NR 1

CD365/5 SAFETY CAP WITH TEFLON O-RING NR 1

CD366/6 O-RING FOR SAFETY CAP NR 1

CD367 DYN FOOT NR 4

CD368 STICK TO HOLD THE CORD UP NR 1

CD369 FUNNEL D. 10 ITEM 013 NR 1

GV028/84/110 ADJUSTABLE SOLEINOID VALVE 110V NR 1

CD374/1 MANOMETER NR 1

CD458 TECHNICAL DATA LABEL NR 2

CV103 METAL RING 1/4 SOLENOID NUT 7000 NR 1

FS012 SCREW M4x22 FOR THERMOSTAT FIXING NR 5

FS017 STAINLESS HANDLE FIXING SCREW M5x10 NR 2

GV025/15 PTFE O-RING FOR HEATING ELEMENT NR 2

Page 24: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.ty

GV025/23 WHITE ZINC-PLATED NUT 4MA 5588 NR 6

GV025/27 EXTESION JOINT NR 2

GV025/30 BOILER INSULATING FOR ITEM I700N NR 9

GV025/31 "L" JOINT FOR SOLENOID VALVE NR 3

GV025/32 O-RING FOR GLASS LEVEL NR 2

GV025/33 CORD 3,5 MT NR 1

GV025/45 FEMALE FRUIT ILME PLUG NR 1

GV025/47 STRAIGHT HOLDER WITH ROD NR 9

GV025/49 CHASSIS NR 1

GV025/51 COPPER HOSE NR 1

GV025/55 SCREW FOR GLASS FIXING 3 MA NR 2

GV025/56 NUT FOR TAP NR 1

GV026/12 TAP NR 1

GV028/1/110 INCOLOY HEATING ELEMENT 1200W 110V NR 2

GV028/12 "L" JOINT FOR TAP NR 2

GV028/15 BASEMENT NR 1

GV028/17 VARNISHED IRON HOLDER NR 1

GV028/18 BRACKET BOILER FIXING NR 1

GV028/19 GLASS FIXING PLAQUE NR 2

GV028/2 STAINLESS STEEL BOILER NR 1

GV028/22 FAIRLEAD FOR TAP NR 1

GV028/27 EXTESION JOINT NR 1

GV028/29 BOILER INSULATING FOR ITEM I700N NR 1

GV028/30 "L" JOINT FOR SOLENOID VALVE NR 1

GV028/33 O-RING FOR GLASS LEVEL NR 2

GV028/36 FEMALE FRUIT ILME PLUG NR 1

GV028/43 JOINT FOR TEDDINGTON NR 1

GV028/45 STRAIGHT HOLDER WITH ROD NR 1

GV028/46 TEDDINGTON PRESSURE SWITCH NR 1

Page 25: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.ty

GV028/47 WIRING FOR I700N/110V 1,5 MM NR 1

GV028/49 CHASSIS NR 1

GV028/50 FRONT CHASSIS NR 1

GV028/52 SCREW NR 4

GV028/60 COPPER STEAMER PIPE NR 1

GV028/61 STEAMER NOZZLE NR 1

GV028/62 T JOINT FOR STEAMER PIPE NR 1

GV028/63 JOINT FOR STEAMER PIPE 1/8 NR 1

GV028/64 RED FIBER GLASS COATING MT 0,56

GV028/69 BOX NR 1

GV028/71 PEDAL NR 1

GV028/72 TUBE NR 1

GV028/73 ANGLE CONNECTION NR 1

GV028/75 HOSE CLAMP NR 1

GV028/76 MANUAL INSTRUCTION NR 1

GV028/9 SCREW FOR CLOSING NR 16

GV029/4 COVER NR 1

MC016/110 POWER CORD 110V NR 1

MC020 BIPOLAR SWITCH NR/NR+ LED RED NR 2

RIC003/2 CERAMIC TERMINAL BLOCK FOR 110V NR 1

Page 26: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700A PARTS DRAWING

Page 27: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700B SPARE PARTS LIST

ITEM DESCRIPTION UM Q.TY

AST113 FLAT WASHER FOR PA012 NR 2

CD024/442 NIPPLE JOINT NR 1

CD332 HANDLE FOR MOD.07/08/09 NR 1

CD332/2 HEXAGONAL HEADED SCREW NR 2

CD338/1 STICK SUPPORT NUT NR 1

CD338/2 WASHER FOR STICK SUPPORT NR 3

CD338/3 STICK SUPPORT NR 1

CD347 FAIRLEAD FOR CAP JOINT NR 1

CD347/7000 FAIRLEAD FOR SOLENOID VALVE NR 1

CD348/1 SCREW FOR BULB THERMOSTAT NR 6

CD348/185 BULB THERMOSTAT 165° NR 2

CD350 RED LIGHT 110V UL APPROVAL NR 1

CD351 CONNECTOR FOR SOLENOID VALVE NR 1

CD356/6 COATED HOSE 5X10 NR 1

CD360 STOP FOR FAIRLEAD 6W-1 NR 1

CD361 STOP FOR FAIRLEAD 6N 3-4 NR 1

CD365/5 SAFETY CAP WITH TEFLON O-RING NR 1

CD366/6 O-RING FOR SAFETY CAP NR 1

CD367 DYN FOOT NR 4

CD368 STICK TO HOLD THE CORD UP NR 1

CD369 FUNNEL D. 10 ITEM 013 NR 1

GV028/84/110 ADJUSTABLE SOLEINOID VALVE 110V NR 1

CD374/1 MANOMETER NR 1

CD378 HOSE CLAMP 10/12 NR 2

CD458 TECHNICAL DATA NR 1

CV043 STEAMER WITH ROUND NOZZLE NR 1

CV103 METAL RING 1/4 SOLENOID NUT 7000 NR 1

FS012 SCREW M4x22 FOR THERMOSTAT FIXING NR 5

FS017 STAINLESS HANDLE FIXING SCREW M5x10 NR 2

Page 28: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV025/15 PTFE O-RING FOR HEATING ELEMENT NR 2

GV025/23 WHITE ZINC-PLATED NUT 4MA 5588 NR 6

GV025/27 EXTESION JOINT NR 2

GV025/30 BOILER INSULATING FOR ITEM I700N NR 9

GV025/31 "L" JOINT FOR SOLENOID VALVE NR 3

GV025/32 O-RING FOR GLASS LEVEL NR 2

GV025/33 CORD 3,5 MT NR 1

GV025/45 FEMALE FRUIT ILME PLUG NR 1

GV025/47 STRAIGHT HOLDER WITH ROD NR 9

GV025/49 CHASSIS NR 1

GV025/51 COPPER HOSE NR 1

GV025/55 SCREW FOR GLASS FIXING 3 MA NR 2

GV025/56 NUT FOR TAP NR 1

GV026/12 TAP NR 1

GV026/7 FEMALE FAST RECEPTACLE NR 1

GV026/9 QUICK RELEASE NR 1

GV028/1/110 INCOLOY HEATING ELEMENT 1200W 110V NR 2

GV028/12 "L" JOINT FOR COCK NR 2

GV028/15 BASEMENT NR 1

GV028/17 VARNISHED IRON HOLDER NR 1

GV028/18 BRACKET BOILER FIXING NR 1

GV028/19 GLASS FIXING PLAQUE NR 2

GV028/2 STAINLESS BOILER NR 1

GV028/22 CHOCK FOR TAP NR 1

GV028/27 EXTESION JOINT NR 1

GV028/29 BOILER INSULATING FOR ITEM I700N NR 1

GV028/30 "L" JOINT FOR SOLENOID VALVE NR 1

GV028/33 O-RING FOR GLASS LEVEL NR 2

GV028/36 FEMALE FRUIT ILME PLUG NR 1

GV028/38 MALE PLUG GROUP NR 1

Page 29: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV028/39 REMOVABLE COVER FOR MALE PLUG NR 1

GV028/40 CABLE PRESS NR 1

GV028/43 JOINT FOR TEDDINGTON NR 1

GV028/45 STRAIGHT HOLDER WITH ROD NR 1

GV028/46 TEDDINGTON PRESSURE SWITCH NR 1

GV028/47 WIRING FOR I700N/110V 1,5 MM NR 1

GV028/49 CHASSIS NR 1

GV028/50 FRONT CHASSIS NR 1

GV028/52 SCREW NR 4

GV028/6 YELLOW BRASS ANGLE CONNECTION NR 1

GV028/69 BOX NR 1

GV028/72 TUBE NR 1

GV028/73 ANGLE CONNECTION NR 1

GV028/75 HOSE CLAMP NR 1

GV028/76 MANUAL INSTRUCTION NR 1

GV028/9 SCREW FOR CLOSING NR 16

GV029/4 COVER NR 1

MC016/110 POWER CORD 110V NR 1

MC020 BIPOLAR SWITCH NR/NR+ LED RED NR 2

RIC003/2 CERAMIC TERMINAL BLOCK FOR 110V NR 1

Page 30: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i700B PARTS DRAWING

Page 31: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i702C SPARE PARTS LIST

ITEM DESCRIPTION UM Q.TY

AST113 FLAT WASHER FOR PA012 NR 2

CD024/442 NIPPLE JOINT NR 1

CD332 HANDLE FOR MOD.07/08/09 NR 1

CD332/2 HEXAGONAL HEADED SCREW NR 2

CD338/1 STICK SUPPORT NUT NR 2

CD338/2 WASHER FOR STICK SUPPORT NR 4

CD338/3 STICK SUPPORT NR 2

CD347 FAIRLEAD FOR CAP JOINT NR 1

CD347/7000 FAIRLEAD FOR SOLENOID VALVE NR 1

CD348/1 SCREW FOR BULB THERMOSTAT NR 6

CD348/185 BULB THERMOSTAT 165° NR 2

CD350 RED LIGHT 110V UL APPROVAL NR 1

CD351 CONNECTOR FOR SOLENOID VALVE NR 2

CD356/6 COATED HOSE 5X10 NR 1

CD360 STOP FOR FAIRLEAD 6W-1 NR 2

CD361 STOP FOR FAIRLEAD 6N 3-4 NR 1

CD365/5 SAFETY CAP WITH TEFLON O-RING NR 1

CD366/6 O-RING FOR SAFETY CAP NR 1

CD367 DYN FOOT NR 4

CD368 STICK TO HOLD THE CORD UP NR 1

CD369 FUNNEL D. 10 ITEM 013 NR 1

GV028/84/110 ADJUSTABLE SOLEINOID VALVE 110V NR 1

CD374/1 MANOMETER NR 1

CD378 HOSE CLAMP 10/12 NR 2

CD458 STEAMER WITH ROUND NOZZLE NR 1

CV043 METAL RING 1/4 SOLENOID NUT 7000 NR 1

CV103 SCREW M4x22 FOR THERMOSTAT FIXING NR 1

FS012 SCREW NR 5

GV025/15 PTFE O-RING FOR HEATING ELEMENT NR 2

Page 32: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV025/19 T JOINT NR 1

GV025/20 JOINT NR 2

GV025/23 WHITE ZINC-PLATED NUT 4MA 5588 NR 8

GV025/27 EXTESION JOINT NR 2

GV025/30 BOILER INSULATING FOR ITEM I700N NR 8

GV025/31 "L" JOINT FOR SOLENOID VALVE NR 5

GV025/32 O-RING FOR GLASS LEVEL NR 2

GV025/33 CORD 3,5 MT NR 1

GV025/45 FEMALE FRUIT ILME PLUG NR 1

GV025/47 STRAIGHT HOLDER WITH ROD NR 8

GV025/49 CHASSIS NR 1

GV025/51 COPPER HOSE NR 1

GV025/55 SCREW FOR GLASS FIXING 3 MA NR 2

GV025/56 NUT FOR TAP NR 1

GV026/12 TAP NR 1

GV026/7 FEMALE FAST RECEPTACLE NR 1

GV026/9 QUICK RELEASE NR 1

GV028/1/110 INCOLOY HEATING ELEMENT 1200W 110V NR 2

GV028/12 "L" JOINT FOR COCK NR 2

GV028/15 BASEMENT NR 1

GV028/16 COVER NR 1

GV028/18 BRACKET BOILER FIXING NR 1

GV028/19 GLASS FIXING PLAQUE NR 2

GV028/2 STAINLESS BOILER NR 1

GV028/22 CHOCK FOR TAP NR 1

GV028/27 EXTESION JOINT NR 1

GV028/29 BOILER INSULATING FOR ITEM I700N NR 1

GV028/30 "L" JOINT FOR SOLENOID VALVE NR 1

GV028/33 O-RING FOR GLASS LEVEL NR 2

GV028/36 FEMALE FRUIT ILME PLUG NR 2

Page 33: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

ITEM DESCRIPTION UM Q.TY

GV028/38 MALE PLUG GROUP NR 1

GV028/39 REMOVABLE COVER FOR MALE PLUG NR 1

GV028/40 CABLE PRESS NR 1

GV028/43 JOINT FOR TEDDINGTON NR 1

GV028/45 STRAIGHT HOLDER WITH ROD NR 2

GV028/46 TEDDINGTON PRESSURE SWITCH NR 1

GV028/47 WIRING FOR I700N/110V 1,5 MM NR 1

GV028/49 CHASSIS NR 1

GV028/50 FRONT CHASSIS NR 1

GV028/52 SCREW NR 4

GV028/6 YELLOW BRASS ANGLE CONNECTION NR 1

GV028/60 COPPER STEAMER PIPE NR 1

GV028/61 STEAMER NOZZLE NR 1

GV028/62 STEAMER JOINT DIAM.6 FOR STEAMER HOSE NR 1

GV028/63 STEAMER JOINT 1/8"F FOR STEAMER NR 1

GV028/64 RED GLASSFIBER COATING FOR STEAMER MT 0,56

GV028/70 BOX NR 1

GV028/71 PEDAL WITH ILME PLUG NR 1

GV028/72 TUBE NR 1

GV028/73 ANGLE CONNECTION NR 1

GV028/75 HOSE CLAMP NR 1

GV028/76 MANUAL INSTRUCTION NR 1

GV028/9 SCREW FOR CLOSING NR 16

MC016/110 POWER CORD 110V NR 1

MC020 BIPOLAR SWITCH NR/NR+ LED RED NR 3

RIC003/2 CERAMIC TERMINAL BLOCK FOR 110V NR 1

Page 34: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

i702C PARTS DRAWING

Page 35: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the
Page 36: Instruction Manual - Vapor SystemsInstruction Manual . USER INSTRUCTIONS i700 – i702 Thank you for purchasing the Reliable™ i700 or i702 series steam boiler. Please follow the

www.reliablecorporation.com