NJT8306 series Instruction Manual Page 1 Copyright © 2015, New Japan Radio Co., Ltd. All rights reserved. This instruction manual may not be reproduced, in part or in whole, without the permission of New Japan Radio Co., Ltd. The specifications and information regarding the products in this instruction manual are subject to change without notice. All statements, information, and recommendations in this instruction manual are believed to be accurate but are presented without warranty of any kind, express, or implied. Users must take full responsibility for their application of any products. IM-T8306 Rev.01 [NJT8306 series] Issue Date: July 7, 2015 Ku-band 6W BUC Instruction Manual for Document Part Number: IM-T8306 Revision: 01

Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 1

Copyright © 2015, New Japan Radio Co., Ltd. All rights reserved.This instruction manual may not be reproduced, in part or in whole,

without the permission of New Japan Radio Co., Ltd.

The specifications and information regarding the products in thisinstruction manual are subject to change without notice.All statements, information, and recommendations in this

instruction manual are believed to be accurate but are presentedwithout warranty of any kind, express, or implied.

Users must take full responsibility for their application of anyproducts.

IM-T8306 Rev.01

[NJT8306 series]

Issue Date: July 7, 2015

Ku-band 6W BUC

Instruction Manualfor

Document Part Number: IM-T8306

Revision: 01

Page 2: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 2

1.

2.

3.

4.

5.

IM-T8306 Rev.01

General Caution

NJRC offers a variety of microwave components intended for particularapplications. It is important that you select the proper component for yourintended application. You may contact NJRC's sales office or salesrepresentatives, if you are uncertain about the products listed in thecatalog and the specification sheets.

Special care is required in designing devices, machinery or equipment,which demand high levels of reliability. This is particularly important whendesigning critical components or systems whose foreseeable failure canresult in situations that could adversely affect health or safety. Indesigning such critical devices, equipment or machinery, carefulconsideration should be given to, amongst other things, their safetydesign, fail-safe design, back-up and redundancy systems, and diffusiondesign.

The products listed in the catalog and specification sheets may not beappropriate for use in certain equipment where reliability is critical orwhere the products may be subjected to extreme conditions. You shouldconsult our sales office or sales representatives before using the productsin any of the following types of equipment.* Aerospace Equipment* Equipment Used in the Deep Sea* Power Generator Control Equipment (nuclear, steam, hydraulic)* Life Maintenance Medical Equipment* Fire Alarm/Intruder Detector* Vehicle Control Equipment (automobile, airplane, railroad, ship, etc.)* Various Safety Equipment

NJRC strives to produce reliable and high quality microwave components.NJRC's microwave components are intended for specific applications andrequire proper maintenance and handling. To enhance the performanceand service of NJRC's microwave components, the devices, machinery orequipment into which they are integrated should undergo preventativemaintenance and inspection at regularly scheduled intervals. Failure toproperly maintain equipment and machinery incorporating these productscan result in catastrophic system failures.

To ensure the highest levels of reliability, NJRC products must always beproperly handled. The introduction of external contaminants (e.g. dust, oilor cosmetics) can result in failures of microwave components.

Page 3: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 3

6.

IM-T8306 Rev.01

NJRC's products have been designed and tested to function withincontrolled environmental conditions. Do not use products under conditionsthat deviate from methods or applications specified in the catalog andspecification sheets. Failure to employ NJRC's products in the properapplications can lead to deterioration, destruction or failure of theproducts. NJRC shall not be responsible for any bodily injury, fires oraccidents, property damage or any consequential damages resulting fromthe misuse or misapplication of its products. PRODUCTS ARE SOLDWITHOUT WARRANTY OF ANY OF KIND, EITHER EXPRESS OR IMPLIED,INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

General Caution (continued)

Page 4: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 4

10

7. Specification ………………………………………………………………………………

5. Physical Description …………………………………………………………………

3. Packing List ………………………………………………………………………………

1. Introduction ………………………………………………………………………………

2. Safety Instructions ……………………………………………………………………

5

11

16 - 18

12 - 15

4. Overview ……………………………………………………………………………………

This instruction manual describes Standard / Universal Ku-band 6W BUC (ModelNo.: NJT8306N, NJT8306F, NJT8306UN, and NJT8306UF) herein referred to as"the Unit".

This instruction manual provides information and instructions for installation andoperation of the Unit.

About This Instruction Manual

6 - 9

IM-T8306 Rev.01

Contents

This instruction manual is intended for use by trained field installers or systemengineers responsible for satellite networks.

19 - 20

6. Installing ……………………………………………………………………………………

Updated instruction manual may be available from NJRC's sales [email protected].

Page 5: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 5

Numbering System

The Unit has the following line-up:

This instruction manual is for Standard / Universal Ku-band 6W BUC (Model No.:NJT8306N, NJT8306F, NJT8306UN, and NJT8306UF).

1. Introduction

The Unit receives a reference signal (10 MHz) and an IF signal (L‐Band: 950 to1,450 MHz or 950 to 1,700 MHz) input and transmits an RF signal (Ku‐Band: 14.0to 14.5 GHz or 13.75 to 14.5 GHz) output.

IM-T8306 Rev.01

The Unit comes in a single, weatherized housing rated for outdoor use. The Unithas either an N-Type or a F-type female connector input, a WR75 waveguideoutput. The Unit is operated by +24 V DC power (Range: +12 to +30 V) input.

Page 6: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 6

IM-T8306 Rev.01

2. Safety Instructions

CAUTION

Statement Symbol Description

NOTE is used to notify ofinstallation, operation, ormaintenance information that isimportant, but not hazard-related.

WARNING indicates a potentiallyhazardous situation which, if notavoided, could result in death orserious injury.

CAUTION indicates a potentiallyhazardous situation which, if notavoided, could result in minor ormoderate injury. CAUTION mayalso be used to indicate otherunsafe practices or risks ofproperty damage.

NOTE

DANGER DANGER indicates an imminentlyhazardous situation which, if notavoided, will result in death orserious injury.

WARNING

Use the following safety guidelines to help protect the Unit from potential damageand to help ensure your own personal safety.

DANGER, WARNING, CAUTION, and NOTE Statements

DANGER, WARNING, CAUTION, and NOTE statements are used throughoutthis instruction manual to emphasize important and critical information. Youmust read these statements to help ensure safety and to prevent productdamage. The statement are defined below.

Page 7: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 7

ELECTRIC HAZARD

HOT SURFACE

2.1. Safety Statements

When installing the Unit, observe the following safety guidelines.

Only input a voltage within the range indicated in specifiedvoltage.DO operate at the input voltage of +12 to +30 V DC power.

Symbol DescriptionGENERIC HAZARD

DO NOT dismantle this product.Dismantlement may cause malfunction and electric shock.

3. RF Radiation

1. Opening / Removing

2. Input Voltage

A radiation hazard exists if the BUC is operated with its RFsignal output unterminated.DO NOT operate the BUC without a load or terminationattached to the RF signal output.

IM-T8306 Rev.01

Page 8: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 8

2.2. Instruction Statements

1. MountingDO NOT block the fins.Normally the Unit should be mounted with long fins face up.

2. WeatherproofThe Unit is mounted outdoors must be adequatelyweatherproofed.Ensure the waveguide joints are properly sealed with thesupplied o-ring (gasket).Use self-amalgamating tape to seal connectors and cable entrypoints from the connector to the cable sheath.

DO NOT input an IF signal over the range of +13 dBmmaximum and a reference signal within the range of -5 to +5dBm.

6. Operating Temperature.Operate the Unit within the ambient temperature range of -40to +65 degree C.

DO NOT touch the body, especially fins, during operating theUnit.High touch temperatures may exist, depending on loadconditions.

4. High Temperatures

IM-T8306 Rev.01

5. Input Level

Page 9: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 9

5. WarrantyOpening or removing any component (e.g. label, and screws)or sealed area will immediately void the warranty.

3. WaveguideDO NOT remove the sealing tape on the waveguide. If thesealing tape is removed, it may lose the performance ofwaterproof.

4. ConnecterConnect the IF cable to the input connector of both N and F-type with 0.68 to 1.13 N·m torque.

IM-T8306 Rev.01

Page 10: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 10

NJT8306FNJT8306UN

Qty(1), Cross-recessed Head Screw (M4x6)

3. Packing List

No.

IM-T8306 Rev.01

The Unit is shipped in a single shipping container with the following content:

Qty(1), O-ring

1.

2.

3. 1 sheet Date sheet

Qty(4), Hexagon Socket Head Bolt (M4x10)

ORNJT8306UF

NJT8306N

Qty(1), Hexagon Wrench Key (M4)

Accessory of BUC

Ku-band 6W BUCQty

1 unit

1 set

Description

Page 11: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 11

4. Overview

IM-T8306 Rev.01

Block Diagram

The unique features are* High Efficiency Output Power P1dB: +37.8 dBm min. over temperature ACPR: -30 dBc typ. @ Pout = +37.8 dBm Power Consumption: 35 W typ. @ No IF Signal 40 W typ. 48 W max. @ Pout = +37.8 dBm* RF Frequency Line-up Universal Ku-band: 13.75 to 14.5 GHz Standard Ku-band: 14.0 to 14.5 GHz* DC Power Operation +12 to +30 VDC* Smaller Size & Lighter Weight Dimension: 174.9 (L) x 84 (W) x 59.2 (H) mm [6.89” (L) x 3.31” (W) x 2.33” (H)] Weight: 1.2 kg [2.6 lbs]* LED Indicator* RoHS Compliance

The Unit transmits an RF signal (Ku‐Band: 14.0 to 14.5 GHz or 13.75 to 14.5GHz) output with up to 6W (+37.8 dBm) linear.

The Unit has the following line-up:

Page 12: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 12

IM-T8306 Rev.01

5.1. Appearance

5. Physical Description

This section describes appearance and outline for the Unit.

Overall Picture(Model No. NJT8306UF)

Page 13: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 13

Caution: DO NOT remove the sealing tape on the waveguide. If the sealing tape isremoved, it may lose the performance of waterproof.

5.2. Outline

5.2.1. Outline Drawing of NJT8306N / NJT8306UN

IM-T8306 Rev.01

Page 14: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 14

Caution: DO NOT remove the sealing tape on the waveguide. If the sealing tape isremoved, it may lose the performance of waterproof.

IM-T8306 Rev.01

5.2.2. Outline Drawing of NJT8306F / NJT8306UF

Page 15: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 15

GroundHole

M4 Threaded Hole Common chassis ground

IM-T8306 Rev.01

PurposeThe Unit receives an IF signal (950 to1,450 MHz or 950 to 1,700 MHz) and areference signal (10 MHz) and isrequired to supply +12 to +30 V DCpower via this connector.The Unit transmits an RF signal (14.0to 14.5 GHz or 13.75 to 14.5 GHz) viathis waveguide.

N-typeORF-typeFemaleConnectorWR-75

LEDIndicator

Item DescriptionIF / ReferenceInputandDC Power Input

RF Output

Local Unlock Alarm GREEN: L.O. locked

5.3. Description of Connectors, Switches, and LEDs

RED: L.O. unlocked (or no referencesignal)

Page 16: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 16

・ ・

When attaching the OMT or the filter, you should follow the followingsteps:

Verify that the o-ring groove on thewaveguide flange of the Unit is clean.Insert the enclosed o-ring (gasket)the groove as shown.

6.1.2. Guidelines for MountingWhen mounting on the OMT or the filter, you should follow the followingcautions:

DO NOT block the fins.Normally the Unit should be mounted with long fins face up.

6.1. Mounting Configuration

6. Installing

This section describes basic installation for the Unit.

IM-T8306 Rev.01

6.1.1. Guidelines for Attachment of OMT

The Unit can be mounted in the feed horn of the satellite antenna.

Step 1:

Step 2: Secure the OMT or the filter to the Unit using the enclosedhexagon socket head bolts (M4x10) with 1.15 to 1.4 N·mtorque as shown, when the thickness of the flange of the OMTor the filter is 3.5 to 5.0 mm.When the thickness is not 3.5 to 5.0 mm, you should preparethe appropriate length screws or bolts.

Page 17: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 17

Connecting the coaxial cable is proceeded with the following steps:Step 1: Connect the coaxial cable with the N or F-type male connectors

to the coaxial connecter equipped with the Unit which is shownin a figure below under 0.68 to 1.13 N·m torque.

Step 2:

Only input a voltage within the range indicated in specifiedvoltage.DO operate at the input voltage of +12 to +30 V DC power atthe coaxial connecter on the Unit.

The Unit receives an IF signal and a reference signal via coaxial cable frommodem, and is required to supply +12 to +30 V DC power via coaxialcable from modem.

IM-T8306 Rev.01

The Unit is connected a coaxial cable and ground wire.

DO NOT input an IF signal over the range of +13 dBmmaximum and a reference signal within the range of -5 to +5dBm.

Use self-amalgamating tape to seal connector and cable entrypoints from the connector to the cable sheath.

6.2. Connecting System

6.2.1. Connecting Coaxial Cable

Supplied the IF/Ref./DC Power via Coaxial Cable

Page 18: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 18

IM-T8306 Rev.01

6.2.2. Fixing Ground WireThe Unit should be common with ground of other equipment (e.g.antenna).

To reduce the risk of damage or broken by lightning surge, theUnit should be fixed with the ground wire.

Fixing a ground wire from the common ground of other equipment forgrounding is proceed with the following step:

Fix the ground wire from other equipment to the ground holenear the coaxial connector with enclosed on the Unit.

Step 1:

Fixing the Ground Wire

Page 19: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 19

Output Frequency Range<Universal Ku-band> 13.75 to 14.5 GHz<Standard Ku-band> 14.0 to 14.5 GHz

Input Frequency Range<Universal Ku-band> 950 to 1,700 MHz<Standard Ku-band> 950 to 1,450 MHz

Maximum IF Input Level +13 dBm max.(without damage)Conversion Type Single, fixed L.O.L.O. Frequency

<Universal Ku-band> 12.80 GHz<Standard Ku-band> 13.05 GHz

Frequency Sense PositiveOutput Power @ 1dB G.C.P. +37.8 dBm min. over temperatureLinear Gain 62 dB nom., 56 dB min.

-60 dBc/Hz max. @ 100 Hz-70 dBc/Hz max. @ 1 kHz-80 dBc/Hz max. @ 10 kHz-90 dBc/Hz max. @ 100 kHz-100 dBc/Hz max. @ 1MHz

<N-type Model> 50 ohms nom.<F-type Model> 75 ohms nom.

13. Input VSWR14.

8.9.

10.Reference

[Phase Noise]

3.

2.

5.

6.7.

7. Specification

No.1.

4.

Specifications

The Unit is in compliance with the following specifications:

12.

11.

-30 dBc typ., -24 dBc min.

-140 dBc/Hz max. @ 10 kHzL.O. Phase Noise

Item

Input Impedance

IM-T8306 Rev.01

[Input Power][Frequency]

Requirement for External

10 MHz (sine-wave)-5 to +5 dBm @ Input port

@ Pout = +37.8 dBm

7.1. Electrical Specifications

ACPR

2 : 1 max.Output Load V.S.W.R.

-125 dBc/Hz max. @ 100 Hz-135 dBc/Hz max. @ 1 kHz

3 : 1 max.1.3 : 1 max.[Recommendation]

[Input Power]

Page 20: Instruction Manual for Ku-band 6W BUC [NJT8306 series] · Step 1: Step 2: Secure the OMT or the filter to the Unit using the enclosed hexagon socket head bolts (M4x10) with 1.15 to

NJT8306 series Instruction Manual Page 20

<N-type Model><F-type Model>

2.

1 mm p-p (3 axis, 5 to 50 Hz)

EMC (2004/108/EC)RoHS (2011/65/EU)Safety: EN60950-1

*1: Conditioned on connection with waveguide.

GREEN: L.O. lockedRED: L.O. unlocked (or no 10 MHz reference signal)

35 W typ. @ No IF signal40 W typ., 48 W max. @ Pout = +37.8 dBm3 W max. @ 10 MHz ref. off (Mute on)

16. Mute Shut off the HPA in case of L.O.unlocked

[Power Consumption]

17. LED Indicator

8. Altitude 15,000 feet (4,572 m)

without Interface Connector

No. Item Specifications15. DC Power Requirement

Performance Guarantee: -40 to +60 ºC

[Voltage Range] +24 VDC (+12 to +30 VDC)

9. Vibration 5 G [49.03 m/s2]5 G [49.03 m/s2] (3 axis, 50 Hz to 2 kHz)

Output Interface3.

F-type female connector, 75 ohms

10. Shock 30 G [294.2 m/s2] (3 axis)

[Operating]

1.2 kg [2.6 lbs]

7. Humidity

1.

[Storage]

Waveguide, WR75 (with Groove)

11. Dustproof / Waterproof

Dimension & Housing

Weight

IF / Ref. / DC Power:N-type female connector, 50 ohms

Input Interface

IM-T8306 Rev.01

5. Cooling Convection Cooling

(L) (W) (H)

4.

84 mm [3.31"]59.2 mm [2.33"]

7.2. Mechanical and Environmental Specification:

6. Temperature Range (ambient)

-40 to +75 °C

Operation Guarantee: -40 to +65 ºC

13. Comply with RoHS (Restricting the use of Hazardous Substances)directives

12. Regulatory Compliance EU Directive (CE Marking)IP67 (IEC 60529) *1

No. Item Specifications

0 to 100 %