16
RANGE (ELECTRICAL) INSTRUCTION AND MAINTENANCE MANUAL “Professionally with Professionals”

INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

RANGE

(ELECTRICAL)

INSTRUCTION AND

MAINTENANCE MANUAL

“Professionally with Professionals”

Page 2: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

DESCRIPTION

Our dear customer,

Your preferred KUSİNA is nature and technology friendly. We thank you for your choice.

KUSİNA has been produced with the understanding of "Total Quality" in modern production facilities.

Important Safety Information

Carefully read this guide and keep it for future review.

WARNING: Installation of the devices must be done by an authorized service person.

WARNING: Equipment must be grounded.

Indicates that there is a risk of personal injury or property damage.

Explosion / fire hazard.

The instructions in this manual contain important information on the safe mounting, usage,

cleaning and maintenance of the device. Thus, keep the manual at a place easily accessible by

the person who will use the machine, and the technician.

Mounting, electrical connection and maintenance works of the device should be performed by a

specialist authorized in this subject and in accordance with the instructions of the manufacturer

company.

Electrical connection of the device should be arranged according to the tables and electrical

diagram given in this manual.

Manufacturer Company accepts no responsibility for the final damages incurred in humans or

properties that are caused by any procedure not conforming to the instruction manual, or

maintenance or technical interventions that are not performed by authorized people.

Product Types • G6K100E – 600 serie ½ module counter top

• G6K200E – 600 serie 1 module counter top

• G7K100E – 700 serie ½ module cupboard

• G7K200E – 700 serie 1 module cupboard

• G7K210E – 700 serie 1 module oven

• G9K100E – 900 serie ½ module cupboard

• G9K200E – 900 serie 1 module cupboard

• G9K210E – 900 serie 1 module oven

Please check the table (1) below for the product specifications

Page 3: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

MOUNTING

Placement Installation and adjustment of the device should be carried out by technical staff of the

Authorized Service.

Place the device at a place min. 10cm away from the side or back wall to prevent excessive

temperature rises.

Place the device beneath a filtered exhaust hood in order to eliminate smell and fume that may

be emitted during cooking.

Device should be placed on a flat surface by suitably balancing on the four adjustable legs.

(Figure A)

Remove the protective nylon on the device. Clean the adhesive particles left on the device with a

suitable cleaner.

Never leave flammable material near the device.

Electrical Connection Connect the device to the electrical installation according to the electrical standards of the

relevant country.

Feed the device with suitable network voltage written on the information plate.

Connect to the electrical installation over a suitable automatic fuse. Fix the said fuse on a place

that is easily accessible in case of a danger.

The cable connecting the device to the electrical installation should be at least type H05 RNF.

Before connecting the electrical inlet cable to the inlet clamp on the device, connect the cable by

passing it through the inlet coupling. And then tighten the coupling cover in a manner that does

not allow cable return.

Electrical inlet is indicated with a label on the device.

If the device will be used in a commercial kitchen, apply a correct grounding system. Here,

consider DIN VDE D100 Article 540.

Grounding screw ” ” is indicated with a label behind the device.

OPERATOR INSTRUCTIONS With the aim of eliminating the protection oil on it, operate the device and ovens at maximum

level for a while. Then, cover with vegetable oil again.

Clean the accumulated food residues that are burned and carbonized on the cooking surface and

oven with a suitable tool everyday at the end of operation. If the said daily maintenance is not

performed, accumulated burned food residues may cause a decline in cooking efficiency by

creating a crust on the plates

Do not operate the oven with its back funnel mouldings removed or closed.

BEFORE USE

Electrical system check After mounting, check the controlling members and heaters by operating at different temperatures.

After the installation and maintenance, check the heating power of device.

During first operation, device will emit fume and smell for a short period. This fume and smell is the

result of the insulation material and the substances such as oil, etc. on the metal sheet surfaces. This is not

dangerous and will disappear by itself.

During the first use of the device should be run in the highest degree of operating for a period of 1 hour

STARTING-UP COOKERS (Figure B) Each plate has 6 adjustable Temperature value. Desired Temperature level is set with relevant

button (1).

1 is the lowest Temperature and 6 is the highest Temperature.

Page 4: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

STARTING-UP OVEN (Figure B) Adjust the thermostat to desired temperature (2).

Adjust cooking area (4), you will see that the indicator light is on.

When the indicator (3) light is off, it means that the oven has reached the desired temperature.

Positions of change over switch is below:

TURN OFF

(Up 1500W down 4500W)

Upper Heater (Up 4500W)

Lower Heater (Down 4500W)

TURN OFF Turn the switch to position “0”.

Turn the thermostat to position “0”.

MAINTENANCE

Do not perform maintenance when the device is loaded with electrical power.

Before it cools down completely, wipe the device with a cloth immersed in warm soapy water.

Do not use cleaning substances and tools that may cause scratches on device surface.

Do not clean the device with water or vapour pressure. Otherwise, you may cause electrical plate

failure.

If the device will not be used for a long period, coat the surfaces with a thin layer of Vaseline. In

case of any dangerous condition with the device, notify to the authorized service. Never let

unauthorized people to interfere in the device.

Figure A

Compatibility Information

This device is designed and manufactured in accordance with the following directives and standards.

marking directive, 93/68/EEC

TS EN 60335-1:2012/AC

TS EN 60335-2:37

Related to CE Directive(s):

2014/35/EU (Low Voltage)

Page 5: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

1 2 43

Şekil BFigure B

1

Figure B

Limitation of Liability: All technical information contained in this manual, operating instructions,

operation and maintenance of the device, contains the latest information on your device. The

manufacturer accepts no responsibility for damage or injury which may result from failure to follow the

instructions in this manual, use outside of the intended use, unauthorized repair, unauthorized

modifications to the device, or use of spare parts not approved by the manufacturer.

Page 6: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

Table (1)

G6K100E G6K200E G7K100E G7K200E

G7K210E G9K100E G9K200E G9K210E

Width (A) mm 400 600 400 800 800 400 800 800

Dept (B) mm 600 600 730 730 730 900 900 900

Hight (C) mm 300 300 900 900 900 900 900 900

Power Kw 3 Kw 8 Kw 3,5 Kw 7 Kw 13 Kw 6 Kw 12 Kw 18 Kw

Electrical Inlet

400 V

3N PE

400 V

3N PE

400 V

3N PE

400 V

3N PE

400 V

3N PE

400 V

3N PE

400 V

3N PE

400 V

3N PE

Cable Sections mm² 5x2,5 5x2,5 5x2,5 5x4 5x4 5x2,5 5x4 5x4

Page 7: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

G6K100E G6K200E

600

300

ELEKTRİK GİRİŞ

ELECTRICAL INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

400

G6K100E

600600

300

ELEKTRİK GİRİŞ

ELECTRICAL INLET

ELEKTRİK GİRİŞ

ELECTRICAL INLET

G6K200E

Page 8: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

G7K100E G7K200E

G7K210E G9K100E

G9K200E G9K210E

Page 9: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

730

900

400

ELEKTRİK GİRİŞ

ELECTRICAL INLET

G7K100E

730

900

800

ELEKTRİK GİRİŞ

ELECTRICAL INLET

G7K200E

730

900

800

Elektrik GİRİŞ

Electrical INLET

G7K210E

Page 10: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

900

900

400

ELEKTRİK GİRİŞ

ELEKTRICAL INLET

G9K100E

900

900

800

ELEKTRİK GİRİŞ

ELECTRICAL INLET

G9K200E

900

900

800

ELEKTRİK GİRİŞ

ELECTRICAL INLET

G9K210E

Page 11: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

PE

M

L3

4 3 1 2 5

P2 P1 P3

4 3 1 2 5

A1

L2

L1

N

400V AC 3N PEG9K100E

P2 P1 P3

A1,2 - PLEYT ŞALTERİ/ PLATE SWİTCHES

R1,2 -PLEYT/ PLATES

5X2.5mm² H07 RNF

R2R1

4 1 3 2

PE

4

3

2

1

A 1 ,2 , 3 ,4

P1 P2 P3

0

1

3

2

5

4

6

1 2 3 4 3 1 5

A2

M - GIRIŞ KLEMENSI/ INLET CLAMP

4 1 3 2

Page 12: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

PEM L3

43

12

5

P2

P1

P3

43

12

5

A1

L2

L1

N

43

12

54

31

25

400

V A

C 3

N P

EG

9K

200E

P2

P1

P3

P2

P1

P3

P2

P1

A1

,2,3

,4 - P

LE

YT

ŞA

LT

ER

İ/ PLA

TE

SW

İTC

HE

S

R1

,2,3

,4 -P

LE

YT

/ PLA

TE

S

5X

2.5

mm

² H07 R

NF

R4

R3

R2

R1

41

32

PE 4 3 2 1

A 1

,2 , 3

,4

P1

P2

P3

013 25 46

12

34

31

5

A2

A3

A4

M - G

IRIŞ

KL

EM

EN

SI/ IN

LE

T C

LA

MP

41

32

41

32

23

14

Page 13: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

PEM L3

43

12

5

P2

P1

P3

43

12

5

A1

L2

L1

N

43

12

54

31

25

11

21

31

12

22

33

H1

F1

40

0V

AC

3N

PE

G9K

21

0E

P2

P1

P3

P2

P1

P3

P2

P1

R6

- FIR

IN A

LT

ISIT

CIL

AR

/ OV

EN

BO

TT

OM

HE

AT

ER

S

R5

-FIR

IN Ü

ST

ISIT

CIL

AR

/OV

EN

TO

P H

EA

TE

RS

A1

,2,3

,4 - P

LE

YT

ŞA

LT

ER

İ/ PL

AT

E S

WİT

CH

ES

A5

- FIR

IN Ş

AL

TE

Rİ/O

VE

N S

WİT

CH

H1

,2 -L

AM

BA

/ LIG

HT

IND

ICA

TO

R

F1

- TH

ER

MO

ST

AT

R1

,2,3

,4 -P

LE

YT

/ PL

AT

ES

5X

4m

m² H

07

RN

F

21

43

1a

2a

3a

4a

5a

6a

21

34

65

p1

p3

p2

p4

8a

7a

87

H2

R6

A5

12

p1

p2

3

1a

43

p4

p3

2a

3a

21

4a

5a

45

7a

6a

8

67

8

A5

R4

R3

R2

R1

41

32

1234M PE

PE

L3

N L1

L2

PE 4 3 2 1

A 1

,2 , 3

,4

P1

P2

P3

013 25 46

12

34

31

5

A1

A1

A1

H2

M - G

IRIŞ

KL

EM

EN

SI/ IN

LE

T C

LA

MP

41

32

41

32

23

14

Page 14: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

11 21 31

12 22 33

H1

F1

400V AC 3N PE

G9K210E-FIRIN

R6 - FIRIN ALT ISITCILAR / OVEN BOTTOM HEATERS

R5 -FIRIN ÜST ISITCILAR /OVEN TOP HEATERS

A1,2,3,4 - PLEYT ŞALTERİ/ PLATE SWİTCHES

A5 - FIRIN ŞALTERİ/OVEN SWİTCH

H1,2 -LAMBA/ LIGHT INDICATOR

F1 - THERMOSTAT

R1,2,3,4 -PLEYT/ PLATES

5X4mm² H07 RNF

21 43

1a 2a 3a 4a 5a 6a

21 3 4 65

p1 p3p2 p4 8a7a

87

H2

R6

A51 2

p1 p2 3

1a43

p4p3

2a 3a

21

4a 5a

4 5

7a6a 8

6 7 8

A5

1

2

3

4

M

PEPE

L3

N

L1

L2

H2

M - GIRIŞ KLEMENSI/ INLET CLAMP

Page 15: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

EVALUATION: APPROVERS

SOLUTION PROPOSAL:

DATE:

PROBLEM DESCRIPTION:

SIGN:

PRODUCT NAME: DETECTED ( Name , Appellation)

CUSTOMER

NAMECUSTOMER COMPLAINT

DETECTION TYPE

CORRECTIVE \PREVENTIVE ACTIVE FORM

OPTIMIZATION REQUEST/

DESCRIPTION

Note: If required, you can send it to our company by viewing the

form above or by post.

Page 16: INSTRUCTION AND MAINTENANCE MANUAL · 2019. 11. 20. · diagram given in this manual. Manufacturer Company accepts no responsibility for the final damages incurred in humans or properties

+90 232 853 92 00

www.kusina.com.tr

İ[email protected]

As a KUSİNA, we realize the production of our devices with CE certificate.

We continue to contribute to the environment using recycled paper.

Manufacturer: Gürçelik Dayanıklı Tüketim Mamülleri Mut. Ins. Tur. Tar.San.Tic. Ltd.Sti.

Adress: Bahçelievler Mahallesi Sakarya Cad. No:11 Yazıbaşı/Torbalı- İZMİR

Phone: +90 232 853 92 00

Web: www.kusina.com.tr – www.gurcelikas.com

E-mail: [email protected]

is a brand.