R EPA CERTIFIED WOODBURNING FIREPLACE Fire Risk. WARNING For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Model(s): Installation Manual Installation and Fireplace Setup WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. DO NOT touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. 7100FP-BK-B 7100FP-NL-B DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. DO NOT overfire. Overfiring will void your warranty. • Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www. quadrafire.com/translations. Installation and s ervice of this applianceshould be performed b y 1 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Installation Manual - Hearth N Homedownloads.hearthnhome.com/installManuals/433_3610.pdf · Installation Manual Installation and Fireplace Setup WARNING HOT SURFACES! Glass and other

  • Upload
    dangnga

  • View
    225

  • Download
    0

Embed Size (px)

Citation preview

R

EPA CERTIFIED WOODBURNING FIREPLACE

Fire Risk.

WARNING

For use with solid wood fuel only.Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).

O-T LTested and Listed by

PortlandOregon USA

OMNI-Test Laboratories, Inc.C US

Model(s):

Installation ManualInstallation and Fireplace Setup

WARNINGHOT SURFACES! Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.• DO NOT touch glass until it is cooled• NEVER allow children to touch glass• Keep children away

• CAREFULLY SUPERVISE children in same room as fireplace.

• Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.• Keep clothing, furniture, draperies and other flammable

materials away.

INSTALLER: Leave this manual with party responsible for use and operation.OWNER: Retain this manual for future reference.

7100FP-BK-B7100FP-NL-B

• DO NOTstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisor any other appliance.

• DO NOToverfire.Overfiringwillvoidyourwarranty.

• Comply with all minimum clearances to com-bustiblesasspecified.Failuretocomplymaycausehousefire.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

Pour demander un exemplaire en français de ce Manuel dupropriétaire,visitezwww.quadrafire.com/translations.

Installation and service of this appliance should beperformedby

1Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwill result in death or serious injury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcould result in death or serious injury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetothefireplaceortoproperty.

Table of Contents1 Product Specific & Important Safety Information

A.FireplaceCertification 4B.BTUEfficiencySpecifications 4C.MobileHomeApproved 4D.GlassSpecifications 5E.Non-CombustibleMaterials 5F.CombustibleMaterials 5G.ElectricalCodes 5

2 Getting Started A. Typical Fireplace System 6B. Design and Installation Considerations 7

1. Selecting Fireplace Locations 72. Locating Fireplace & Chimney 8

C. Tools and Supplies Needed 9D. Inspect Fireplace and Components 9E.FireplaceSystemRequirements 9

3 Framing and Clearances A. Fireplace Dimensions 10B. Clearances 11

1.MinimumClearancestoCombustibles 12C. Construct the Chase 13D.FrametheFireplace 14E.SecureandLeveltheFireplace 14F. ProtectiveMetalHearthStrips 15G.FacingMaterial 15H.OutsideAirKit 16I. AuxiliaryConvectionAirSystem 18J. HeatZoneKit(Optional) 19

4 Electrical Wiring 5 Chimney and Termination Requirements

A.ChimneyRequirements 23B.Offsets/Returns 24C.TerminationRequirements 25

6 Chimney Installation A. Typical Chimney System 26B.AssembleChimneySections 27C.InstallChimneyAirkit(CAK4A) 27D.SecureOffset/Return 29E. Install Ceiling Firestops 29F. Install Attic Insulation Shield 30G. Roof Penetration 31H.ManufacturedHomeInstallation 31I. InstallChase/ChaseTop 32J. TerminationCapRequirements 33K. Install Termination Cap 33

7 Finishing A.Template 35B FinishtheWall 35

1.Stone,BrickFinish 352.Tile,Granite,MarbleFinish 35

C. Mantel and Wall Projections 36D.FinishingtheHearthExtension 36E.Non-CombustibleSealantMaterial 38

8 Fireplace Setup A.FirebrickPlacement 39B.BaffleandBlanketPlacement 40C.InstallFascia(Fronts) 40

9 Reference Materials A.ChimneyComponents 41B.Accessories 45MESH-HHTFirescreen 45

2 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Customer:Lot/Address

Model (circle one): 7100FP-BK-B 7100FP-NL-B

YES IF NO, WHY?Fireplace InstallVerified that the chase is insulated and sealed. Requirednon-combustibleboardisinstalled.Verifiedclearancestocombustibles.Fireplaceisleveledandsecured.Hearthextensionsize/heightdecided.Outsideairkitinstalled.OptionalHeatZonehasbeeninstalledbyaqualifiedservicetechnician.

Chimney Section 5 Chimney configuration complies with diagrams.Chimney installed, locked and secured in place with proper clearance. Chimney air kit installed.Firestops installed.Attic insulation shields installed.Roof flashing installed and sealed.Terminations installed and sealed.

Electrical Section 4 Switch wires properly installed.

Dealer/Distributor Phone #Serial #:

WARNING! Risk of Fire or Explosion! Failure to install fireplace acording to these instructions can lead to a fire or explosion.

ATTENTION INSTALLER:Follow this Standard Work Checklist

Thisstandardworkchecklististobeusedbytheinstallerinconjuctionwith,notinsteadof,theinstructionscontainedinthisinstallationmanual.

Date Installed:Location of Fireplace:Installer:

Finishing Section 7 CombustibleCombustiblematerialsmaterialsnotnotinstalledinstalledininnon-non-combustiblecombustibleareasareas.Verifiedallclearancesmeetinstallationmanualrequirements.Mantelsandwallprojectionscomplywithinstallationmanualrequirements. Protectivehearthstripsandhearthextensioninstalledpermanualrequirements.

Fireplace Setup Section 8 Allpackagingandprotectivematerialsremoved.Firebrick,baffleandceramicblanketinstalledcorrectly.Facia and doors properly installed.Manualbagandallofitscontentsareremovedfrominside/underthefireplaceandgiventothepartyresponsibleforuseandoperation.Allpackagingmaterialsareremovedfrominside/underthefireplace.

Hearth & Home Technologies recommends the following:• Photographing the installation and copying this checklist for your file.• Thatthischecklistremainvisibleatalltimesonthefireplaceuntiltheinstallationiscomplete.

Commentscommunicatedtopartyresponsible

Part#4017-254•RevB•01/29/13

__________________________by______________________on_________(Builder/Gen.Contractor)(Installer)(Date)

Comments:Furtherdescriptionoftheissues,whoisresponsible(Installer/Builder/OtherTrades,etc.)andcorrectiveactionneeded:_________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

3Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

1 Product Specific & Important Safety Information

Model: 7100FP

Laboratory: OMNITestLaboratories,Inc.Report No: 061-S-41-2

Type: Wood Fireplace

Standard: UL127-2011 and ULC-S610-M87 (A1998)and(UM)84-HUD,Manu-facturedHomeApproved.

A. Appliance Certification

NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.

C. Mobile Home Approved This appliance is approved formobile home installationswhen not installed in a sleeping room and when an outside combustionair inlet isprovided.Thestructural integrityofthemobilehomefloor,ceiling,andwallsmustbemaintained.Theappliancemustbeproperlygroundedtotheframeofthemobilehomeanduseonlylisteddouble-wallconnectorpipe.D. Glass SpecificationsThisapplianceisequippedwith5mmceramicglass.Replaceglassonlywith5mmceramicglass.Pleasecon-tact your dealer for replacement glass.

Improper installation, adjustment, alteration, service ormaintenance can cause injury or property damage.

Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.

• Installation and use of any damaged appliance. • Modificationoftheappliance. • InstallationotherthanasinstructedbyHearth&Home Technologies. • Installationand/oruseofanycomponentpartnotapproved byHearth&HomeTechnologies. • Operatingappliancewithoutfullyassemblingall components. • DoNOTOverfire-Ifapplianceorchimneyconnectorglows, youareoverfiring.Anysuchactionthatmaycauseafirehazard.

WARNINGFire Risk.Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

B. BTU & Efficiency SpecificationsNOTE: This installation must conform with local codes. In the absenceoflocalcodesyoumustcomplywiththeUL127-2011, (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S610-M87 (A1998) and CAN/CSA-B365 Installation Codes in Canada.

The 7100FPmeets the U.S. Environmental ProtectionAgency’scribwoodemissionlimitsforwoodheaterssoldafterMay15,2015.

EPACertification#: 5714-1-03EPACertifiedEmissions: 3.1 grams per hour*LHVTestedEfficiency: 77.6 %**HHVTestedEfficiency: 71.8%

***EPABTUOutput: 12,100to58,800/hr.****PeakBTU/HourOutput: 92,400

VentSize: 8 inchesFireboxSize: 3.4cubicfeet

RecommendedLogLength: 24inchesFuel Seasoned Cord Wood

ChimneySize: 8 inchesHHT: SL300 Series

DuraVent: DuraPlus**WeightedaverageLHV(LowHeatingValue)efficiencyusingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.LHVassumesthemoistureisalreadyinavaporstatesothereisnolossinenergytovaporize.****WeightedaverageHHV(HighHeatingValue)efficiencyusingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.HHVincludestheenergyrequiredtovaporizethewater in the fuel.***ArangeofBTUoutputsbasedonEPADefaultEfficiencyandtheburnratesfromthelowandhighEPAtests,usingDouglasFirdimensionallumber.****A peak BTU out of the appliance calculated using the maxi-mumfirsthourburnrate fromtheHighEPATestand theBTUcontentofcordwood(8600)timestheefficiency.

4 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

G. Electrical Codes

NOTICE: This fireplace must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1.

• A110-120VACcircuitforthisproductmustbeprotectedwith ground-fault circuit-interrupter protection, in compliancewiththeapplicableelectricalcodes,whenit is installed in damp locations.

WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam-age.

Hearth&HomeTechnologiesWILLNOTwarrantyappli-ancesthatexhibitevidenceofover-firing.Evidenceofover-firingincludes,butisnotlimitedto: • Warpedairtube • Deterioratedrefractorybrickretainers • Deterioratedbaffleandotherinteriorcomponents

E. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing: - Steel - Plaster - Brick - Iron - Concrete - Tile - Glass - SlateMaterials reported as passing ASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C. F. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingmaterials: - Wood - Compressed Paper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)Anymaterialthatcanigniteandburn:flameproofedornot, plastered or un-plastered.

5Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

2 Getting Started

Termination Cap

Chimney penetrates roof preferably without affectingroof rafters

Offset/Return (with hanger straps)

Attic insulation shield must be used to keep insulation away from chimney if attic is insulated

Storm Collar

Framing headed off in ceiling joists

Mantel

Chimney system

Combustible framing/headeron top of V-shaped standoffs (spacers)

Non-combustible material

Hearth extension

Non-combustibleroof flashing maintainsminimum clearancearound chimney

Additional lateralsupport for chimneyabove roof (or enclosedin chase) if needed

Enclosed space aboveand around fireplace

Ceiling firestopon floor of attic

Support strapson rafter supportschimney (not shown)

Outsidecombustion air

Outsidecombustion air

Chimney Air Kit (CAK-4A) (not shown) must be used with SL300 chimney

Protective metalhearth strip(s)

A. Typical Fireplace System

Figure 2.1 Typical Fireplace System

6 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

D

CA

E

F

AH

GB

A

B

B

AI

In an exterior chase or projecting into a garage

Across a corner

Along a wall

As a room divider

24 in. (610mm)

24 in. (610mm)

24 in. (610mm)

48 in. (1219mm)

*If interior of chase will be drywalled, add the thickness to this measurement.

°Faceplate to sidewall

24 in. (610mm)

I

A

*

*

*

*

Figure 2.2 Fireplace Locations

NOTICE:• Illustrations and photos reflect typical installations and

are FOR DESIGN PURPOSES ONLY.• Illustrations/diagrams are not drawn to scale.• Actual installation/appearance may vary due to individual

design preference.• Hearth & Home Technologies reserves the right to alter

its products.

NOTICE: In addition to these framing dimensions, also reference the following section:

• Clearances (Section 3).

NOTICE: A minimum 1/2 in. air clearance at the back and a minimum 1 in. air clearance to the sides of the fireplace assembly must be maintained.Chimney sections at any level require a 2 in. mini-mum air space clearance between the framing and chimney sections.

B. Design and Installation Considerations

NOTICE: Check building codes prior to installation.

• Installation MUST comply with local, regional, state and national codes and regulations.

• Consult insurancecarrier, localbuildinginspector,fireofficialsorauthoritieshavingjurisdictionoverrestrictions,installation inspection and permits.

1. Selecting Fireplace LocationsThis fireplace may be used as a room divider, installedalong a wall, across a corner or used in an exterior chase. See Figure 2.2.

Locating the fireplace in a basement, near frequentlyopened doors, central heat outlets or returns, or other loca-tionsofconsiderableairmovementcanaffect theperfor-mance.

Outside air must be used for combustion. The 7100FPcomesequippedwithanoutsideairinlettofeedcombus-tion air from outside the home, along with an outside air terminationcap;themetalductisrequiredbutnotsupplied.Considerationshouldbegiventothesefactorsbeforede-ciding on a location.

Model # 7100FP A B° C D E F G H I

(Dimensionsfor finishedwalls)

in. 42-1/2 16 89-1/2 63-5/16 22-7/16 44-3/4 14-1/16 56-9/16 54-1/2

mm 1080 406 2273 1608 570 1137 357 1437 1384

7Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

2. Locating Fireplace & Chimney

Locationofthefireplaceandchimneywillaffectperfor-mance.

• Installwithinthewarmairspaceenclosedbythebuildingenvelope.Thishelpstoproducemoredraft,especiallyduringlightinganddie-downofthefire.

• Penetrate the highest part of the roof. This minimizes the effects of wind loading.

• Locate termination cap away from trees, adjacent structures,unevenrooflinesandotherobstructions.

• Minimize the use of chimney offsets. • Considerthefireplacelocationrelativetofloorandceiling

and attic joists.• Takeintoconsiderationtheterminationrequirementsin

Sections5and6.

Marginal Location:• Below peak

Location NOT recommended:• Not the highest point of the roof• Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended Location:• Above peak

Recommended:• Insulated exterior chase

in cooler climates

Recommended Location:• Above peak• Inside heated space

Location NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wall

Marginal Location:• Wind loading possible

Not recommended in basement due to high negative pressure concerns that effect draft

Figure 2.3 Recommended Chimney Locations

• Installtheoutsideairkitwiththeintakefacingprevailingwinds during the heating season.

• Ensure adequate outdoor air for all combustionappliancesandexhaustequipment.

• Ensurefurnaceandairconditioningreturnventsarenotlocatedintheimmediatevicinityofthefireplace.

• Avoid installingthefireplaceneardoors,walkwaysorsmall isolated spaces.

• Recessedlightingshouldbea“sealedcan”design.• Attic hatches weather stripped or sealed.• Attic mounted duct work and air handler joints and seams

taped or sealed.

8 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

C. Tools and Supplies NeededBeforebeginningtheinstallationbesurethefollowingtoolsandbuildingsuppliesareavailable:

Reciprocating saw Framing material

Pliers Non-combustiblesealant

Hammer Gloves

Phillipsscrewdriver Framingsquare

Flatbladescrewdriver Electricdrillandbits

Plumbline Safetyglasses

Level Tapemeasure

1/2-3/4in.length,#6or#8self-drillingscrews

Misc. screws and nails

D. Inspect Fireplace and Components

WARNING! Risk of Fire and/or Explosion! Damaged parts could impair safe operation. DO NOT install dam-aged, incomplete or substitute components. Keep fire-place dry.

• Removefireplaceandcomponentsfrompackagingandinspect for damage.

• Vent system components and doors are shipped in separate packages.

• Report to your dealer any parts damaged in shipment.• Read all the instructions before starting the

installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

E. Fireplace System RequirementsTheQuadra-Firefireplacesystemrequirementsconsistofthefollowing:

• Fireplace- Firebrick(includedwithfireplace)- Door(includedwithfireplace)- Non-combustible facingmaterial (included with

fireplace)- HearthExtension

• OutsideAir System (hood and collars includedwithfireplace)

• Fascia• Chimney System

- Chimneyairkit(includedwithfireplace,requiredwithSL300serieschimney)

- AtticInsulationShield(includedwithfireplace)- Chimney termination cap

• Non-combustiblefinishmaterial

Optionalcomponentsinclude:• Firescreen• Lintel Bar• HeatZoneKit

9Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

3 Framing and Clearances

A. Fireplace Dimensions

CL

Blower Electric Access(right side of fireplace)

3-1/2 in.(89 mm)

32-1/2 in.(826 mm)

38 in.(965 mm)

40 in.(1016 mm)

42-5/16 in.(1075 mm)

45-13/16 in.(1148 mm)

23-7/16 in.(595 mm)

13-3/16 in.(335 mm)

10-13/16 in.(259 mm)

4-5/16 in.(109 mm)

6 in.(152 mm)

1 in.(25 mm)

13-3/4 in.(349 mm)

9-7/16 in.(240 mm)

42 in.(1067 mm)

Auxilary

Outside Air

3 in.(76 mm)

1in.(25 mm)

1/2 in.(13 mm)

Figure 3.1 Fireplace Dimensions

10 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

B. ClearancesWARNING! Risk of Fire!

You must comply with all minimum air space clearances to combustibles as specified in Figure 3.2. DO NOT pack required air spaces with insulation or other materials. Framing or finishing material used on the front of, or in front of, the fireplace closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc.). Failure to comply may cause fire.

Figure 3.2 Clearances to Combustible Materials

(ceiling)

(roof)

(ceiling)

2 in. (51 mm) min.

Attic Insulation

Shield

Ceiling Firestop(attic)

Storm Collar

Roof Flashing

2 in. min.(51 mm)

2 in. (51 mm) min.

2 in. (51 mm) min.

Ceiling Firestop Offset/Return with hanger straps

2 in.(51 mm)

min.

2 in. (51 mm) min.

Must have 2 in. (51 mm)minimum clearance

to header

Electrical wires must be 3-1/2: (89mm) from top

0 in. to levelof standoffs

1 in. (25mm) to side of appliance

1/2 in. (13 mm) to backof appliance

0 in.to floor

36 in. (914 mm) standoffs to ceiling

Chimney Air Kit required with SL chimney

11Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

1. Minimum Clearances to Combustibles

Position combustible/ non-combustible mantel60 in. (1524 mm) from base of fireplace

12 in.(305 mm)

46-1/4in.(1175 mm)

24 in.*(610 mm) 48-1/2 in.

(1232 mm)

42-1/2in.(1080 mm)

The �nished cavity depth must be no less than 24 in. (610 mm) from the �nished backwall to the outside of front wall framing.

2 x 4s must be used for the header and framing above the header to maintain pipe clearances.

Double studs to catch non-combustible board and wall facing material.

*If interior of chase will be drywalled, add the thickness to this measurement.

12 in.(305 mm)

When installing the outside air with an elbow/bend, allow a minimum cavity of 12 in. (305mm)

14 1/2 in. (368 mm) for SL300 Chimney16 in. (406 mm) for DuraPlus Chimney

Figure 3.3 Framing the Fireplace

WITHIN ENCLOSURE AREAFireplacetobackwall 1/2in.(13mm)Fireplace to sidewall 1in.(25mm)Ductbootstoframing 0in.(0mm)Top standoffs to header 0in.(0mm)Door opening to sidewall 22-7/8in.(581mm)

EXPOSED SURFACESFaceplate to sidewall 16in.(406mm)Heatzoneairgrillstoceiling 12in.(305mm)

MANTELNon-combustiblemantel(Non-combustibleframingmaterialsabovethefireplacetoceiling) 46in.(1168mm)Combustiblemantel(Combustibleframingmaterialsabovethefireplacetoceiling) 60in.(1524mm)Maximum mantel depth 12in.(305mm)

12 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

C. Construct the ChaseAchaseisaverticalboxlikestructurebuilttoenclosethefireplaceand/oritsventsystem.Verticalchimneysthatrunontheoutsideofabuildingmustbeinstalledinsideachase.

Incoldclimates,Hearth&HomeTechnologiesrecom-mendsthatthechasebewellinsulatedusingbatttypeinsulationbetweenthejoists.

Constructionofthechasemayvarywiththetypeofbuild-ing.Theseinstructionsarenotsubstitutesfortherequire-mentsoflocalbuildingcodes.LocalbuildingcodesMUSTbechecked.

Chasesshouldbeconstructedinthemannerofalloutsidewallsofthehometopreventcoldairdraftingproblems.Thechaseshouldnotbreaktheoutsidebuildingenvelopeinanymanner.Allouterwallsneedtobeinsulated.

Buildingcodesrequirefalseceilingandceilingfirestops/atticshieldsateachfloorofthechaseorevery10ft(3048mm)ofclearspacetocontrolspreadoffire.

Walls,ceiling,baseplateandcantileverflooratthefirstlevelofthechaseshouldbeinsulated(seeFigure3.4.)Vaporandairinfiltrationbarriersshouldbeinstalledinthechase as per regional codes for the rest of the home. Ad-ditionally,Hearth&HomeTechnologiesrecommendsthattheinsidesurfacesbedrywalledandtaped(ortheuseofanequivalentmethod)formaximumairtightness.

Holesandotheropeningsshouldbecaulkedwithhightemperaturecaulkorstuffedwithunfacedfiberglassinsulation.

Ceiling Firestop

Metal Chase Top

Round Termination Cap

False Ceiling

Insulation in the outside walls of the chase

Attic Insulation

Shield

Chimney

Ceiling Firestop

Tabs

False Ceiling False Ceiling Insulation Insulation

Storm Collar

Figure 3.4 Chase Assembly

1 2 3

All outside walls should be insulated.

Figure 3.5 Chase Constructions

1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney offset through exterior wall and enclosed in chase. 3. Chase constructed on roof.

• The chase is constructed using framing materials much thesameasthewallsinyourhome.Avarietyofsidingmaterialsmaybeused includingbrick, stone, veneerbrick,orstandardsidingmaterials.

• In constructing the chase, several factorsmust beconsidered:- Maintain a 2 in. (51mm) air space around the

chimney.- The chase top must be constructed of non-

combustiblematerial.- Incoldclimates,afirestopspacerandatticinsulation

shieldshouldbeinstalledinaninsulatedfalseceilingat the 8 ft. (2438mm) level above the fireplaceassembly.Thisreducesheatlossthroughthechase.

- Incoldclimates, thewallsof thechaseshouldbeinsulatedtothelevelofthefalseceilingasshowninFigure3.4.Thiswillhelpreduceheatlossfromthehomearoundthefireplace.

Three examples of chase applications are shown in Fig-ure3.5.

WARNING! You must install false ceilings and ceil-ing firestops at each floor of the chase or every 10 ft (3.05 m) to control spread of fire.

WARNING! Risk of Fire! DO NOT seal area between fire stop opening and chimney pipe except where they enter the attic or leave the warm air envelope of the home (use 600° F sealant).

WARNING! Risk of Fire! You must maintain a minimum 2 in. (51 mm) air space clearance to insulation and other materials surrounding the chimney system.• Insulation and other materials must be firmly secured to

prevent accidental contact with chimney system.• The chase must be properly blocked to prevent blown

insulation or other combustibles from entering and making contact with fireplace or chimney.

• Failure to prevent contact between insulation or other materials and chimney system may cause overheating and fire.

13Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

D. Frame the Fireplace

NOTICE: Hearth extension designmust be determinedbeforeinstallationoffireplace.

Ifthefireplaceisplacedonthefloorthemaximumheightofafinishedraisedhearthis5-3/4”, ifyouwantahigherraisedhearththefireplacemustbeplacedonaplatform.

NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone Kit, it also must be installed before enclosure is complete.

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles. DO NOT pack required air spaces with insulation or other materi-als.

WARNING! Risk of Fire! Comply with all minimum clear-ances specified.• A minimum 1/2 in. (13 mm) air clearance must be

maintained at the back and 1 in. (25 mm) to the sides of the fireplace assembly.

• Chimney sections at any level require a 2 in. (51 mm) minimum air space clearance between the framing and chimney section.

Figure3.3showsatypicalframing(using2x4lumber)ofthefireplace,assumingcombustiblematerialsareused.All required clearances to combustibles around the fire-placemust be adhered to. See Figure 3.2.Any framingacrossthetopofthefireplacemustbeabovethelevelofthetopstandoffs.(Norecessabovestandoffs.)

The finished cavity depth must be no less than 24 in.(610mm)fromthefinishedbackwalltotheoutsideoffrontwall framing. Framing must extend straight up all the way to the ceiling.

CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.

WARNING! Risk of Fire! Prevent contact with sagging, loose insulation. • DO NOT install against vapor barriers or exposed

insulation.• Secure insulation and vapor barriers.• Provide minimum air space clearances at the sides and

back of the fireplace assembly as outlined in Section 3.

E. Secure and Level the FireplaceThis fireplacemaybeplacedoneither a combustible ornoncombustiblecontinuousflatsurface.Followtheinstruc-tionsforframinginSection3.Slidethefireplaceintoposi-tion.Besuretoprovidetheminimum1in.airclearanceatthesidesand1/2in.atthebackofthefireplace.

Thefireplaceshouldbepositionedsothefaceofthenon-combustiblematerialonthefireplacewillbeflushwiththeface of the drywall on the walls. See Figure 3.6.

Levelthefireplaceandshimasnecessary.Securethefire-place(usingthepalletmountingbracketslocatedoneithersideofthefireplace)tothesubfloor.

These surfaces must be even!

Drywall Non-combustiblefacing material

Figure 3.6 Drywall - Non-combustible Facing Material

Standoffs are attached to the fireplace.The unit can be positioned with the standoffs touchingcombustiblewallsorframingbutDONOTpackinsulationorothermaterials intheairspacebetweenthefireplaceand wall.

14 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

1in. (25 mm) Overlap

Metal strips 2 in. (51 mm) under edge of Fireplace and Hearth Extension and extended 2 in. (51 mm) beyond both sides of fireplace opening.Nail or screw metal strips in place.

Pallet Mounting/Floor Brackets

Raised Platform

Floor

2 in.(51 mm)

1 in. (25 mm) min.overlap

2 in.(51 mm)

Top piece must overlapbottom piece

Figure 3.8 Protect the Front of an Elevated Platform

F. Protective Metal Hearth Strips

Figure 3.7 Position the Protective Metal Hearth Strips

• Locatethetwoprotectivemetalhearthstripsmeasuringapproximately26in.x4in.(660mmx102mm)includedwiththisfireplace.

• Slideeachmetalstrip2in.(51mm)underfrontedgeoffireplace.

• Overlapstripsinthemiddleoffireplaceopeningby1in. (25mm)minimum.

• Metal stripsmust extendbeyond the front and sidesof the fireplace opening by at least 2 in. (51mm),Figure3.7).

• Protectthefrontofaplatformelevatedabovethehearthextensionwithmetalstrips(notincludedwithfireplace)per Figure 3.8. See Section 6 for hearth extension instructions.

WARNING! Risk of Fire! Protective metal hearth strips MUST be installed on combustible surfaces. DO NOT cover metal strips with combustible materials. Sparks or embers may ignite flooring.

WARNING! Risk of fire! High temperatures, sparks, embers or other burning material falling from the fireplace may ignite flooring or concealed combustible surfaces.• Protective metal hearth strips MUST be installed.• Hearth extensions MUST be installed exactly as

specified.

WARNING! Risk of Fire!Follow these instructions exactly.Facing materials must be installed properly to prevent fire.No materials may be substituted without authorization by Hearth & Home Technologies.

G. Facing Material

TOOLS NEEDED: Powered drill with #2 Phillips head bit;caulking gun.Onlynon-combustiblematerials(suppliedwithfireplace)maybeusedtocoverthemetalfireplacefront.

NOTE: All boards are pre-drilled for your convenience. Boards MUST be attached in the following order: bottom, top, and then the two sides, red-painted side out. The top and bottom board should each have a hang tag attached. Leave them attached for referral for the finishing operation.

• Attach the bottom board to the bottom of the outerfireplacecanwithenclosedscrews,ensuringtheboardis centered. DO NOT remove hang tags.

• Centerandattachthetopboardtotheoutercanandframingmembers. DO NOT remove hang tags.

• Using the SuperCalstick, run a light bead (1/8 in.minimum)between themetalsurfaceof thefireplaceandthebuttedgesofthetopboard.See Figure 3.9.

• Ensuringthetopofthesidepiecesandthetopboardalign, attach the side pieces to the outer can and framing members.

NOTICE: 1/8 in. of the facing material may be visible after finishing materials are applied. This 1/8 in. must be painted or the red will show.

Figure 3.9 Apply Non-combustible Materials

Side Board

Bottom Board

Side Board

Top Board

DO NOT remove hang

tags

Apply bead of Super Calstick to

edge here

15Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

H. Outside Air KitAnoutsideairkitmustbeusedforcombustion.Hearth&HomeTechnologiesrecommendsyouutilizetheshortestduct run to optimize the performance of the outside air kit.Theoutsideairinlethoodshouldbepositionedinamannerthatwillnotallowsnow,leaves,etc.toblocktheinlet.Insomeinstallationstheairductmayneedtoberunvertically.Insuchaninstallation,a3ft(914mm)heightdifferencemustbemaintainedfromthetopoftheupper-most chimney section to the outside air inlet hood.

Refer to Figures 3.10 and 3.11 when placing the outside air inlet hood.

The outside air kit is installed on the right hand side of the fireplace.SeeFigure3.12forhandlelocation/operation.

• Cut a 6-1/2 in. (165mm) hole in outside wall toaccommodate air piping.

• Use6in.(152mm)metalflexorrigidpiping(notsupplied)todirectlyconnectoutsideairtofireplaceintake.Insulatethepipetopreventfrostcondensation.

• Insulating thepipe isn’t requiredbutwillhelppreventfrost condensation.

• Use the supplied outside air inlet hood.• Seal between thewall and the pipewith silicone to

preventmoisturepenetrationandairleaks.• Sealbetweentheoutsideairinlethoodandthehouse

withsiliconetopreventairinfiltration.

CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.

CAUTION! Risk of Fire or Asphyxiation! DO NOT draw outside combustion air from wall, floor or ceiling cavity, or enclosed spaces such as an attic or garage. • DO NOT place outside air inlet hood close to exhaust

vents or chimneys. Fumes or odor could be drawn into the room through the fireplace.

• Locate outside air inlet hood to prevent blockage from leaves, snow/ice, or other debris. Blockages could cause combustion air starvation.

16 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

3 ft. (91cm) min. from top of uppermost chimney section to outside air inlet.

Locate outside air inlet to prevent blockage from leaves, snow/ice, or other debris.

Attic insulation shield must be used to keep insulation away from chimney.

Ceiling firestop on floor of attic

Outlet blocked bysnow, leaves, etc.

NO

Garage orcombustible

liquids storage

NO

Attic spaceNO

Outlet placedhigher than 3 ft

below thetermination cap

NO

UL181 Listed Class 0 or Class 1 metal flex orrigid duct

Clear area outside

house or in ventilated

crawl space

YES

Figure 3.11 Outside Air Installation

Figure 3.10 Outside Air Inlet Locations

17Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

I. Auxiliary Convection Air SystemNote: Both the outside air and auxiliary air kits are installed ontherighthandsideofthefireplace.

Theauxiliaryconvectionairsystemallowstheoptionatthetimeofinstallationofthefireplace,toruna6inch(152mm)diameterducttotheoutsideofthehome,andbringoutsideairoverthefanswhereitisheatedandthendistributedintotheroom.Thisproducesapostivepres-sure inside the home.

Figure 3.13 Auxiliary Convection Air Duct

Alternatively,a6inch(152mm)ductcanberuntoan-other location in the home and used as a cold air return withinthehomeanddistributedintotheroomwherethefireplaceislocated.SeeFigure3.13.

If no ducting is installed, the fans will pull air from the roomandre-circulateheatedairbackintotheroom.

Figure 3.12 Outside Air

Termination Caps supplied with fireplace

UL 181 Listed Class 0 or Class 1 metal flex or rigid duct

Outside Air intake

Auxiliary Convection

Air

Open/Close Knob for

outside air

OUTSIDE AIR

OPENCLOSED

Auxiliary Convection Air LeverTheauxiliaryconvectionair lever is locked fromthe fac-tory.Ifyouaregoingtousethisfunctionforairmovementyoumustremovethelock.

Afterremovingthefascia,removetheonescrewandplatetoallowthehandletobemovedinthefullmotionrighttoleft.SeeFigure3.14.

Discard the plate and screw. Replace fascia.

Theauxiliaryconvection lever is locatedunderneath thefrontlowerpanelasshowninFigure3.14.

Figure 3.14 Auxiliary Convection Air Lever

8-32 Screw

Convection Lock Bracket

NOTICE:If you live in an area with very cold winter months, you will want to use room air as opposed to bringing in ex-tremely cold air from outside of the home. This will eliminate creating a draft of cold outside air infiltrating your home. Definitely keep the lever to the LEFT when not using the fireplace if the duct has been installed.

18 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

DUCT RUN REQUIREMENTS

MAXIMUMDuctRun=40-ft.(12m)MINIMUMDuctRun=36in.(914mm)

DUCTING MATERIAL

6in.(152mm)B-VentOnlyDONOTductintoexistingfurnaceplenum

MINIMUM CLEARANCE TO COMBUSTIBLES

1in.(25mm)fromtheB-Vent1/2in.(13mm)fromtop&bottomofoutletbox0in.(0mm)fromthesidesofoutletbox12in.(305mm)fromwallregistertoceilingRefertoFigure3.15.

CAUTION! ALL wiring should be done by a qualified elec-trician and shall be in compliance with local codes and with the National Electric Code NFPA/NEC No. 70-current. CSC22.1 Canadian Electric Code.

Possible Air Duct Runs / Locations

Figure 3.15 Minimum Clearances to Combustibles

J. Heat Zone Kit (Optional)TheHeat-Zoneaccessorykitconveyswarmairfromthefireplacethroughairduct(s)toremotelocationsinthesameroomorotherroomsofthebuilding.Youmayinstall1or2Heat-Zonekitsonthefireplace.Installationofthiskit MUSTbeperformedbyaqualifiedservicetechnician.If any parts are missing or damaged, contact your local dealerbeforestartinginstallation.DONOTinstalladam-aged kit.

This kit is tested and safe when installed in accordance withthisinstallationmanual.Itisyourresponsibilitytoreadallinstructionsbeforestartinginstallationandtofol-low these instructions carefully during installations.

TheHeat-Zone®Woodkitiscarefullyengineeredandmustbeinstalledonlyasspecified.Ifyoumodifyitoranyofitscomponentsyouwillvoidthewarrantyandyoumaypossiblycauseafirehazard.Installationmustbedoneaccordingtoapplicablelocal,state,provincialand/ornational codes.

Planthelocationofthefireplaceandwarmairductrun(s).

Ceiling RegisterWall Register

Floor Register

Two Duct Kits

Ceiling Register

12 in. (305mm) minimum clearance from register to ceiling

17 in. (432mm) minimum clearance to allow for venting

19Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Installation• Removetheknockoutorcoverplatefromthetopofthe

fireplaceanddiscardit.SeeFigure3.16.• Cuta3in.(76mm)holeintheinsulationboardasper

the dimensions shown in Figure 3.16.

Adapter

Mounting Plate

Starter Pipe

Knockout

Cut a 3 in. (76 mm)

hole in insulation board

3-13/16 in. (97 mm)

3-1/8 in. (79 mm)

CL

Run Length Cut Pipe20 - 40 ft (6-12 m) 2 in. (51 mm)*

*A minimum of 2 in. (51 mm) pipe must be used to cover the raw insulation to prevent it from blowing out through the return air grille.

10 - 20 ft (3 - 6 m) 8 in. (203 mm) 3 - 10 ft (1 - 3 m) No cut needed**

**Use full 16 in. (406 mm) as supplied

• Determine the necessary length of starter pipe from the Table3.1andcutasrequired.

Figure 3.16

• Slide the starter pipe into the fireplace,matching theholesintheplatetotheholesinthefireplace.

• Place the adapter on the mounting plate lining up holes. Using four sheet metal screws included in the kit, secure the adapter andmounting plate into fireplace.Aftersecuringtothefireplace,tapedowntheadapteredgestothetopofthefireplacewithaluminumtapetopreventleakage.

• Determine the location for the air register and fan housingassembly.Cuta7-5/8in.x13-5/8in.(143mmx346mm)holebetweenframingmembers(wallstudsorfloor joists).Thebracketscanberotated180°andmountedtothebacksideofthe2x4ifnecessary.SeeFigure 3.18.

NOTICE: The fan and electrical connections must be accessible for servicing per local code requirements.

NOTICE: If the fan housing is installed in a 2 x 4 wall, the front of the housing will protrude approximately 1/4 in. (6 mm) from the finished wall.

• Attachenough6 in. (152mm)B-Ventas required foryour installation to the fan housing. A maximum of (4) 90° elbows is recommended. Securely twist lock the B-Vent to the adapter. AlsoscrewtheB-Venttotheoutletboxonthefan

housing. See Figure 3.19. Supportductatintervalsofnogreaterthan4ft(1m)asrequiredbylocalcode.

Figure 3.17

WARNING! Risk of Fire! Comply with all minimum clearances specified.• A minimum 1 in. (13 mm) air clearance must be

maintained at the back and 1 in. (25mm) to the sides of the fireplace assembly.

NOTE: It is important the pipe length be adhered to or it will affect the performance of your fireplace.

• Onthemountingplate,handbendthetabsdownward.Slidethetabsovertheoutsideofthestarterpipe.Securewith four sheet metal screws included in fasteners package. Figure 3.17.

Table 3.1

20 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Securely Twist Lock B-Vent to Adapter

Secure B-Vent to Fan Housing with sheet metal screws

Return Air GrilleInstall with Louvers pointed down

Bracket

Can rotate 180o

2 x 4 Wall

Fan Housing

1/2 in. (13mm)clearance tocombustiblesmust bemaintained.

2 x 4 wall

Sheet Rock

Leave 1/4" (6mm) clearance from all 4 outer edges

Seal grille using gasketing supplied with the kit

• Installthevariablespeedwallrheostat(withsettingon“OFF”)inaconvenientlocation.ThisswitchwillcontroltheHeat-Zonefanoperation.

• Remove the junctionbox.Wire110VACserviceTOthewall rheostatandFROM thewall rheostat to thefanjunctionbox.Usewirenutstosecurethe110VACservicewirestothehot(black)andneutral(white)fanwires and screw the 110 VAC ground wire to the junction box.SeeFigure3.21.

• Secure the return air grille to the fan housing making sure it is flush.Thegrillemust be installedwith thelouverspointingdown.

NOTICE: DO NOT USE ADJUSTABLE REGISTERS.

Junction Box Removed

Wire Clamp

Wire Nuts

Junction Box

Bla

ck

White

NOTICE: Secure the duct so that clearance to the fire-place outer wrap is maintained. Tape all seams with alumi-num tape 1-1/4 in. (32 mm) minimum width or as specified by local codes.)• Seal all the way around the inside of the return air grille to

preventhotairbeingdrawnbackintotheventingsystemusinggasketingsuppliedwiththekit.Leave1/4in.(6mm)clearancefromallfourouteredges.Trimexcessgasketing. See Figure 3.20.

Figure 3.18

Figure 3.19

Figure 3.20

Figure 3.21

21Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

14-2 w/ground

Standard wall mount with Junction Box

14-3 w/ground

WIRE NUT

WHITE

GREEN

BLACK

BLAC

K

RED

WHITEMatch colors to wire harness (red to red, white to white, etc) and secure with a wire nut

Incoming Power(110V)

Power to the FireplaceSnap Disc bypass switch

Figure 4.1 Fan Wiring Diagram

NOTICE: The manual override switch, rheostat speed control and cover plate are supplied. You will need to supply: 14-3 wire with ground; 14-2 wire with ground; standard wall mount junction box; wire nuts.

• Remove junctionboxcoverplateon thebottomrightsideofthefireplace.

• Threadthe14-3withgroundwirethroughtheopeningwiththestrainreliefonthecoverplate.

• Matchcolorstowireharness,(redtored,whitetowhite,etc.)andsecurewithwirenuts.

WARNING! Risk of Fire! DO NOT apply combustible fin-ishing materials over any part of the front of this fireplace.• The metal fireplace face may only be covered with

noncombustible materials such as ceramic tile, brick, or stone.

• Do not cover or block any cooling air slots.

NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

4 Electrical Wiring

22 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

6 ft (1.8 m) max.unsupportedrun

20 ft (6.10 m) max.pipe between anoffset & return

Ceiling firestop

35 ft (10.7 m)max. straightunsupported

chimney height

14.5 ft (4.42 m) min. height/single offset-return20 ft. (6.10 m) min. height/double offset-return

50 ft (15.24 m) max. height

6 ft (1.83 m) max.unsupported chimneyabove roof

45 3/4 in.(1162 mm)to top of standoffs

Attic Insulation Shield

Chimney Air Kit required with SL

chimney

Figure 5.1 Chimney Requirements

NOTICE: A maximum of two pairs of offsets and returns may be used.

Minimum overall straight height 13 ft 3.96 mMinimum height with single offset/return

14.5 ft 4.42 m

Double offset/return minimum height 20 ft 6.1 mMaximum height 50 ft 15.24 mMaximum chimney length between an offset and return

20 ft 6.1 m

Maximum distance between chimney stabilizers

35 ft 10.67 m

Maximum unsupported chimney length between the offset and return

6 ft 1.83 m

Maximum unsupported chimney height above the fireplace

35 ft 10.67 m

Maximum unsupported chimney above roof

6 ft 1.83 m

WARNING! Risk of Fire! You must maintain 2 in. (51 mm) air space clearance to insulation and other combustible materials around the chimney system. Failure to do so may cause overheating and fire.

NOTICE: You must provide support for the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

A. Chimney RequirementsVerticaldistancesaremeasuredfromthebaseofthefireplaceasshowninFigure5.1.

5 Chimney and Termination Requirements

Table 5.2 Chimney Component DimensionsTable 5.1 Chimney Requirements

HEIGHT OF CHIMNEY COMPONENTS in. mm

Chimney Stabilizer

SL3 4-3/4 121

Offsets/Returns

SL315 13-3/8 340

SL330 15-1/2 394

Chimney Sections*

SL306 4-3/4 121

SL312 10-3/4 273

SL318 16-3/4 425

SL324 22-3/4 578

SL336 34-3/4 883

SL348 46-3/4 1187

* Dimensions reflect effective height.

Note: 8in.DuraPluscanalsobeused.

23Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Table 5.3 Offset Dimensions

B. Offsets/Returns• Useanoffset/returntobypassoverheadobstructions.• Anoffsetandreturncanbeusedasasingleentityorseparatedbychimneysection(s).

WARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheating and fire. Secure offsets with screws ( not to exceed 1/2” / 13 mm in length) Secure returns with strapping. Straight chimney sections may be secured with screws. Keep chimney sections from separating or twisting.

• Measuretheshiftneededtoavoidtheoverheadobstruction.RefertodimensionAinFigure5.2.• FindtheappropriateAdimensionlistedinTable5.3.TheBdimensioncoincidingwiththeAdimensionmeasurementin

Table5.3representstherequiredverticalclearanceneededtocompletetheoffset/return.• Readacrossthecharttofindthenumberofchimneysections/modelnumbersneededbetweentheoffsetandreturn.

A

B

1-1/4 in. (32 mm)OVERLAP

Figure 5.2 Chimney Offset/Return

Example: Your“A”dimensionfromFigure5.2is14-1/2in.(368mm).UsingTable5.3thedimensionclosestto,butnotlessthan14-1/2in.(368mm)is14-1/2in.(368mm)us-inga30°offset/return.

Youdeterminefromthetablethatyouneed34-1/8in.(867mm)(Dimension“B”)betweentheoffsetandreturn.

ThechimneycomponentthatbestfitsyourapplicationisoneSL324.

15-degree 30-degree

SL306 SL312 SL318 SL324 SL336 SL348A B A B

in. mm in. mm in. mm in. mm15/8 41 133/8 340 35/8 92 151/2 394 - - - - - -

27/8 73 173/4 451 51/2 140 185/8 473 1 - - - - -

41/8 102 223/8 568 71/4 184 213/4 552 2 - - - - -

41/2 114 235/8 600 81/2 216 233/4 603 - 1 - - - -

53/4 146 281/4 718 101/4 260 27 686 1 1 - - - -

6 152 293/8 746 111/2 292 29 737 - - 1 - - -

71/4 184 34 864 131/4 337 321/8 816 - 2 - - - -

73/4 197 361/8 918 141/2 368 341/8 867 - - - 1 - -

83/4 222 393/4 1010 161/4 413 373/8 949 1 - - 1 - -

103/8 264 455/8 1159 191/4 489 421/2 1080 - - 2 - - -

105/8 270 463/4 1187 201/2 521 445/8 1133 - - - - 1 -

117/8 302 513/8 1305 221/4 565 473/4 1213 1 - - - 1 -

131/2 243 571/4 1454 251/4 641 527/8 1343 - - - 2 - -

133/4 349 583/8 1483 261/2 673 55 1397 - - - - - 1

15 381 63 1600 281/4 718 581/8 1476 1 - - - - 1

161/2 419 683/4 1746 311/4 794 631/4 1607 - 1 - - - 1

18 457 745/8 1895 341/4 870 681/2 1740 - - 1 - - 1

195/8 498 803/8 2042 371/4 946 733/4 1873 - - - 1 - 1

205/8 524 841/8 2137 391/8 994 767/8 1953 1 - - 1 - 1

223/4 578 917/8 2334 431/4 1099 841/8 2137 - - - - 1 1

24 610 961/2 2451 451/8 1146 871/4 2216 1 - - - 1 1

257/8 657 1031/2 2629 491/4 1251 941/2 2400 - - - - - 2

Properassemblyofair-cooledchimneypartsresultinanoverlapatchimneyjointsof1-1/4in.(32mm).Effectivelengthisbuiltintothischart.

24 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Slanted Roofs

Flat Roofs

Chimney mustextend 3 ft (.9 m)above the roof

Chimney must extend 2 ft (.6 m)above any portion of the roof oradjacent structures within 10 ft (3 m) of the chimney

Chimney mustextend 3 ft (.9 m)above the roof

Chimney must extend 2 ft (.6 m)above any portion of the roof oradjacent structures within10 ft (3 m) of the chimney

Multiple Chimney Locations

A B6 in. (minimum) up to 20 in.

152 mm/508 mm18 in. minimum

457 mm20 in. and over 0 in. minimum

Gas, Wood or Fuel OilTermination Cap

WoodMinimum

(Seeillustration

above)

B

GasTermination

Cap **

A *

Per

pend

icul

ar W

all

* If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

** In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap.

Figure 5.3 Multiple Chimney Locations

C. Termination Requirements• Installacapapprovedandlistedforthisfireplacesystem.• Locatecapwhereitwillnotbecomepluggedbysnoworothermaterials.• Locate cap away from trees or other structures.• Thebottomoftheterminationcapmustbeatleast3ft(.91m)abovetheroofANDatleast2ft(.61m)aboveanyportion

ofroofwithin10ft(3.05m)asshowninFigure5.3.• ThedistancerequiredbetweencapsisshowninFigure5.3.

25Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

6 Chimney Installation

Termination Cap

Additionalsupport fortall chimneys

Storm Collar

Maintain minimumclearances to combustibles asspecified

Chimney must extendbeyond combustibleroof structure

Maintain minimumheight of chimneyabove roof

Install roof flashingaccording to minimumrequirements

Offsets/returnsmay not exceed30° from vertical Support straps for offsets/

returns must be securedto adequate framing

Ceiling firestopsare required wherechimney passes through ceiling orfloor

Attic Shield isrequired where chimneypasses through attic

Figure 6.1 Typical Chimney System - Guidelines for Chimney System Installation

NOTICE: Chimney performance may vary.

• Trees, buildings, roof lines and wind conditions affect performance.• Chimney height may need adjustment if smoking or overdraft occurs.

A. Typical Chimney System

TheSL300serieschimney(UL127approvedforusewiththisfireplace)isshippedwithwraparoundwarninglabelsinstalled.Theselabelsmayberemovedfromthesectionsofchimneyexposedabovetheroofline.

26 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Attach Flue First

CAK4A

Secure with Screws Provided

Push TogetherSecure to Top

C. Install Chimney Air kit (CAK4A)

NOTICE: Chimney Air Kit, Part CAK4A is required when using the SL-300 Pipe Series. Detailed instructions are supplied with the kit. If using the Dura-Plus System (must be 8 in./203 mm in diameter), the starter ring that came with the fireplace must be removed and replaced with the Dura-Plus Base Plate. The CAK4A is not required with a Dura-Plus System.

• Installthechimneypipefirst.• Handbend the tabs inpositionbeforeplacingon the

fireplace.• Placetheboxontopofthefireplacearoundthechimney

pipe,pushbothpiecestogetherandsecurewithscrewsprovided.

• Usethepre-punchedholesinthetabsasguidesanddrillholesthroughthefireplacetop.

• SecuretheCAK4Ainplace.SeeFigure6.3.• Seal around the kit at the flue and at the top of the

canwithhightempcaulkwithaminimumratingof500degrees. See Figure 6.3.

Figure 6.3 Installing the CAK4A

NOTICE: Chimney sections cannot be disassembled once locked together. Plan ahead!

• Lockchimneysectionsand/oroffsets/returnstogetherbypushing downward until the top section meets the stop beadonthelowersection.

• Pull on the top section to make sure it is fully engaged and will not separate.

• You may use #6 or #8 sheet metal screws no longer than 1/2in.(13mm)tofastenchimneysectionstogether.DoNOTpenetrateinnerflue.

WARNING! Risk of Fire! You MUST use screws to fas-ten offset/returns to chimney sections to keep the chim-ney parts from twisting. Failure to do so could cause fire.

• Fasten offset/returns to chimney sections. DoNOTpenetrateinnerflue.

• Secure chimney returnswithhanger strapsprovided;fasten to studs or joists.

• Verticalstraightrunsofchimneymustbesupportedevery35ft(10.7m).

B. Assemble Chimney Sections Useonlythosecomponentsdescribedinthismanual.

Substituteordamagedchimneycomponentscouldimpairsafeoperationandcauseoverheatingandfire.

Attach either a straight chimney section or an offset to the topofthefireplace(dependingonyourinstallationrequire-ment).Chimneysectionsare locked togetherbypushingdownwarduntilthetopsectionmeetsthestopbeadonthelower section.

Theinnerflueisplacedtotheinsideofthefluesectionbelowit.Theoutercasingisplacedoutsidetheoutercas-ingofthechimneysectionbelowit.SeeFigure6.2.

WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components.

Figure 6.2 Assembling Chimney Sections

27Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

NOTES: • TheCAK4Aterminationcapmustbeaminimumof4ft

(1219mm)abovethegroundandkeptfreeofdebris.• If theCAK4A is installed inachase, theCAK4Aside

terminationcapmustbeat least3ft(914mm)belowthe chimney top.

• Sealaroundthecapandflexwithcaulktostopairfromgettingintothechase(seeFigures6.4).

• The pipe cannot lay on top of the unit.

Wire TiesSeal

Seal

4" Duct - Use UL181 Class 0 or Class 1 ducting.

NOTE: The pipe cannot lay on top of the unit.

Figure 6.4 Installing Flex Pipe

WARNING! Risk of Fire!• The flex pipe must never be compressed or deformed!• Restricting the airflow inside the flex pipe may increase

flue pipe temperatures causing a chase fire.

28 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

D. Secure Offset/Return

E. Install Ceiling Firestops CAUTION! Risk of Fire! Ceiling firestops must be used

whenever the chimney penetrates a ceiling/floor.• Chase construction requires ceiling firestops at each

floor or every 10 ft. (3.05 m) of clear space.• The ceiling firestop slows spread of fire and reduces

cold air infiltration.

• Installaceilingfirestopwheneverchimneypenetratesceiling/floor.

• Mark and cut an opening in ceiling as shown in Figure 6.6.• Frametheopeningwiththesamesizelumberusedin

the ceiling joists.• Nailtheceilingfirestoptothebottomoftheceilingjoists

whenthereisaroomabove.• Use an attic insulation shield if the ceiling is insulated.

Theceilingfirestopmaythenbeattachedaboveorbelowthe joists.

ROOM ABOVE (non-insulated ceiling)

ATTIC ABOVE (insulated ceiling)

B A

Ceilng firestop attached to bottom

of framing

Ceiling firestop attached to top of

framing

Note: Use same dimensional lumber for framing ceiling firestop and joists.

2 in. (51mm) clearance

2 in. (51mm) clearance

WARNING! Risk of Fire! DO NOT seal area between firestop opening and chimney pipe except where they en-ter the attic or leave the warm air envelope of the home (use 600° F sealant).

Figure 6.6 Installing the Ceiling Firestop

When offsets and returns are joined to straight pipe sec-tions,theymustbelockedintopositionwithscrews(outeronly).Topreventgravityfrompullingthechimneysectionsapart,thereturnsandthechimneystabilizershavehangerstraps for securing these parts to joists or rafters. See Fig-ure6.5.

* Use # 6 or # 8 sheet metal screw, or larger, no longer than1/2in.(13mm).

WARNING! Risk of Fire!• Secure offsets with screws (not to exceed 1/2 in./13 mm

In length).• Secure returns with strapping.• Straight chimney sections may be secured with screw

(not to exceed 1/2 in./13 mm In length) at the joints.• Keep chimney sections from separating or twisting.

CeilingFirestop

Straps

OptionalAdditionalSupport

JointBand

(Optional)

Figure 6.5 Secure the Chimney

Catalog #A B

in. mm in. mm

FS338 14-1/2 368 14-1/2 368

FS339 14-1/2 368 18-3/8 467

FS340 14-1/2 368 23 584

29Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Installationofaceilingfirestopisrequired:

• RefertoFigures5.5,5.6,5.7.• Iftheatticshieldispre-rolledcontinue.Ifitisaflatpart,

try and roll it up to aid in wrapping it around the chimney.• Pre-bendallthetabsinatthetopto45°.• Wraptheshield(aroundthechimneyifalreadyinstalled)

untilyouhaveanoverlapandthethreeholesoneachsidematchup(largeholesontop).

• Insert three screws into the matching holes to form a tubestartingatthebottom.

• Bendthetabsonthebottomofthetubeinwardto90°tomaintain chimney air space.

• Resttheinsulationshieldontheceilingfirestopbelow.• Tapeoffanyopeningaroundthebottom.

Ifyouwishtomakeacustomshieldorbarrier,followtheseguidelines:

• Metal is preferred, although any material stiff enough to holdbacktheinsulationcanbeused.

WARNING! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi-ronmental conditions is not recommended.

• The shield or barriermust be tall enough to extendabovetheinsulationandpreventblown-ininsulationfromspillingintothecavity.

• Maintainspecifiedairspacesaroundchimney.• Check instructions and local codes for further details.

Insert three screws

Pre-bend the tabs to rest against pipe to prevent insulation from falling in.

(5)Tabs bent in 90°

Figure 5.5 Prepare Attic Insulation Shield

F. Install Attic Insulation ShieldWARNING! Risk of Fire! You MUST install an attic insu-lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney. • DO NOT pack insulation between the chimney and the

attic insulation shield. • Failure to keep insulation and other materials away from

chimney pipe could cause fire.• DO NOT offset chimney inside insulation shield.• Combustible material may come in contact with the attic

insulation shield as long as the required clearances are maintained to the chimney pipe.

Double-check the Chimney AssemblyContinueassemblingthechimneysectionsupthroughthe ceiling firestops as needed. While doing so, beaware of the height and unsupported chimney length limitationsgivenunderSection5.

Checkeachsectionbypullingupslightlyfromthetoptoensureproperengagementbeforeinstallingthesuc-ceedingsections.Iftheyhavebeenconnectedcorrect-ly, they will not disengage when tested.

Figure 5.6 Install Attic Insulation Shield (firestop above ceiling)

5 Tabs bentin 90°

Tabs bent in to rest against pipe

Attic Insulation Shield

Ceiling Firestop

10-1/2 in.(267 mm)

14-1/2 in. (368 mm)diameter

InsulationInsulation

Pipe

Pipe

2 in. (51 mm)air space

Seal with tape

5 Tabs bentin 90°

Tabs bent in to rest against pipe

Attic Insulation Shield

Ceiling Firestop10-1/2 in.(267 mm)

14-1/2 in. (368 mm)diameter

InsulationInsulation

Pipe

Pipe

2 in. (51 mm)air space

Seal with tape

Figure 5.7 Install Attic Insulation Shield (firestop below ceiling)

30 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

G. Roof Penetration• Refer to Figure 6.10.• Plumbfromrooftocenterofchimney.• Driveanailupthroughrooftomarkcenterofpipe.• Measuretoeithersideofnailandmarkthe14-1/2in.x

14-1/2in.(368mmx368mm)openingrequired.• Measure opening on the horizontal; actual length may

belargerdependingonroofpitch.• Cut out and frame opening.• Refer to Chapter 25 of the Uniform Building Code for

roof framing details.

Figure 6.10 Ceiling/Attic Construction

Install Flashing• Assemblechimneysoitpassesthroughtheframed

opening.• Sliptheflashingoverthechimney.

NOTICE: Roofing shingles must be below the flashing plate on the lower side of a sloped roof and over the flashing plate on the sides and top.

• Nailtheflashingtotheroof.Keepgapsbetweentheflashingplateandtherooftoaminimum.

• Caulktheflashingplateandroofjunctionaswellastheverticalseamontheflashing.Allnailheadsmustbecaulkedwitharoofingsealant.

• Caulktheoverlapseamofanyexposedpipesectionsthatarelocatedabovetherooflinetopreventleaks.

CHIMNEY

FLASHING PLATE

JOISTS

NAIL

THIMBLE

FLASHING

Figure 6.11 Installing Part: 12966A, Configuration 1

NOTICE: REQUIRED for manufactured homes.

• Locatethepointwherethechimneywillexittheroofbyplumbingdowntothecenterofthechimney.Layout,cutand framea14-1/2 in. (368mm)squareopening(measuredonthehorizontal)throughtheceilingandroofstructure. Consult local codes for framing details.

• The thimblemustextendcompletely through theroofstructureshieldingcombustiblematerials.Fivelocationholeshavebeenprovidedtoallowforavarietyofceiling/roofthicknesses.Athimbleextensionisrequiredwhentheceiling/roofthicknessexceeds12-1/2in.(318mm).Theextensionshouldoverlapthethimbleoneinch.

• Toattachtheextensiontothethimble,drill1/8in.(3mm)holesthroughtheoutershieldofthethimbleusingthepredrilled holes in the extension as guides. Attach the extensiontothethimbleusingthescrewsprovidedwiththe extension.

• Installthethimbleassemblyandnailitsecurelytotheframingmembers.

H. Manufactured Home Installation SL-300 Series Ceiling/Roof Thimble

• Centertheflashingoverthechimneyandnailittotheroof.Keepgapsbetweentheflashingplateandtherooftoaminimum.Caulktheflashingplateandroofjunctionaswellastheverticalseamontheflashing.Allnailheadsmustbecaulkedwitharoofingsealant.

• Finish assembling the chimney storm collar andtermination cap following the installation instructions providedwiththem.

31Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

NAIL

FLASHING PLATE

CHIMNEY

THIMBLE EXTENSION

SCREW

FLASHING

THIMBLE ADJUSTABLE EXTENSION HOLES

Figure 6.13 Installing Part 12966A Configuration 3

I. Install Chase/Chase Top• You MUST use a chase top in a chase installation.

Chase tops are available from yourQuadra-Firedealerormaybefieldconstructed.

• Includeaturndownanddripedgetopreventwaterfrom seeping into the chase.

• Includea2 in. (51mm)soldered,weldedorspuncollar around pipe opening to keep water out.

• Providea1/8in.(3mm)gaparoundthefluepipe.• Slope the chase top downward away from the

opening.

WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. • Caulkallseamstopreventleaks.

Slope Downward(1/4 in. per footminimum)

Turn-down Drip Edge

Chase

2 in. (51 mm) Collar on Chase Top

.018 (26 ga) min. Galvanized Chase Top

Figure 6.14 Chase Top Construction

FLASHING

CHIMNEY

FLASHING PLATE

NAIL THIMBLE

SCREW

THIMBLE EXTENSION

Figure 6.12 Installing Part 12966A, Configuration 2

32 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

J. Termination Cap Requirements• Installacapapprovedandlistedforthisfireplacesystem.• Locatecapwhereitwillnotbecomepluggedbysnow

or other materials.• Locate cap away from trees or other structures.• Thebottomoftheterminationcapmustbeatleast3ft

(.91m)abovetheroofANDatleast2ft(.61m)aboveanyportionofroofwithin10ft(3.05m).

StormCollar

ChimneyPipe

Chase Top

TerminationCap

Chase

6 in. (153 mm)Minimum top ofchase to top ofchimney pipe

Collar2 in. (51 mm)

Minimum Height

Do NOTblock air holes

Caulk gaps between storm collar & pipe,

and storm collar& chase top.

Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm).

Slipstorm collar

around chimney pipebefore termination

cap pipe is snapped into the chimney

pipe.

Figure 6.15 Installing a TR344 Round Termination Cap

K. Install Termination CapInstall the chimney sections up through the chase enclo-sure.

• Caulktheoverlapseamofanyexposedpipesectionsthatarelocatedabovetherooflinetopreventleaks.

• Refer to termination cap instructions.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

Figure 6.16 Installing a TR342-B Round Telescoping Termination Cap

StormCollar

ChimneyPipe

Chase Top

TerminationCap

Chase

4 3/4 in. (121 mm)Maximum

Collar2 in. (51 mm)

Minimum Height

Caulk gaps between storm collar & pipe,

and storm collar& chase top.

Do NOT block air

holes3 clip brackets.

Slip over chase collarand attach with screws

provided.

Assemblestorm collar

around extended termination cap

pipeonce cap is

installed.

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

2 in. (51 mm)maximum

33Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Figure 6.19 Installing a TCT375 Terra Cotta Cap

Figure 6.17 Installing an ST375 Square Termination Cap

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Flange

2 in. (51 mm)maximum

4 3/4 in. (121 mm)maximum

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

2 in. (51 mm)maximum

4 3/4 in. (121 mm)maximum

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

Figure 6.18 Installing a TS345/TS345P Square Termination Cap

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Remove 2 screws from front & back to lift the top off

Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

The last section of pipe must stop between 2 in. (51 mm) above top of chase and 4-3/4 in. (121 mm) below top of chase

2 in. (51 mm)

4-3/4 in. (121 mm)

34 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

7 Finishing

A. TemplateAcardboardtemplateofthefrontisprintedontheoutsideoftheshippingbox.Cutoutthetemplatealongtheout-side of the line for use in your installation. A metal tem-plate(seecatalog)isavailableformoredurablecontin-ueduse,remainingaccurateovertime.Bothmeasure1/8in.(3mm)largerallthewayaroundthantheactualfront.

Note:This1/8in.ofthenon-combustiblematerialmustbepaintedortheredwillbevisible.

Tools Required: 1/8in.Allenwrench.• Removethedoorsonthefireplace(ifinstalled).• Removethescrewsfromthefasciaandremovefascia

fromthefireplace(ifinstalled).Savethescrews.Storethefasciainasafe,protectedareatopreventscratchingor other damage.

• Installthetemplateonthefrontofthefireplace(Figure7.1)usingthescrewssavedinthepreviousstep.

You are now ready to continue your installation with the desireddecorativematerial.Thetemplatealsoservesasaprotectivecoveringandpreventsdamagetothefrontofthefireplace.

NOTE: The decorative fascia must be removable for future serviceability of the automatic combustion control.

Figure 7.1 Install the Finishing Template

Note: DO NOT remove hang tags until installing finishmaterials.

B Finish the WallUseawetordrytowelorasoftbrushtoremoveanydustordirtfromthenon-combustiblefacingmaterial.

Applyanon-combustibleadhesivetoattachtile,stoneorothernon-combustiblefinishingmaterialspermanufac-turer’s instructions.

1. Stone, Brick FinishWARNING! Risk of Fire! DO NOT apply tar paper or water resistive barrier over non-combustible board.

• Applymetallathtothe1/2in.thicknon-combustibleboardwith corrosion resistant self-tapping screwscapableofpenetratingthemetalsurfacebehindthenon-combustibleboard.

• HHT recommendsusing typeNor typeSmortar.Duetohightemperatures,reviewpolymermodifiersspecificationsheetbeforeusing.

2. Tile, Granite, Marble Finish• Duetohightemperatures,HHTrecommendsusing

unmodifiedthinsetwhenapplyingtile.• Whenapplyinggraniteormarble,HHTrecommends

usingthinsettoadhere.Ifusingadifferentadhesive,review specification sheet for application in hightemperature areas.

Figure 7.2 Template Dimensions

38.25”

27.44”

(R37.13)

32.75”

35Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

C. Mantel and Wall ProjectionsAcombustiblemantelmaybepositionednolowerthan60in.(1524mm)fromthebaseofthefireplace.

Minimum clearance faceplate to sidewall is 16 in.

Thecombustiblemantelmayhaveamaximumdepthof12in.(305mm).Combustibletrimpiecesthatprojectnomorethan3/4in.(19mm)fromthefaceofthefireplacecanbeplacednocloserthan6in.(152mm)fromthesideofthedecorativefront.Surroundlegsthatprojectmorethan3/4in.must be 16 in. away from the side of the decorativefront.Combustibletrimmustnotcover:

• themetalsurfacesofthefireplace• where the non-combustible board is placedover the

metal surfaces• thespacebetweenthemetalfaceofthefireplaceand

framingmembers

60 in.(1524 mm)

Mantel

Clearances are from bottom of appliance to lower edge of mantel or trim

Trim

48 in.(1219 mm)

36 in. (914 mm)

Ceiling/enclosure

Trim 3/4 in. max

Figure 7.3 Mantel Specifications - Combustible Mantel

D. Finishing the Hearth Extension

Table 7.1

R = 1/k x inches of thickness

Table 7.2

WARNING! Risk of Fire! High temperatures, sparks, em-bers or other burning material falling from the fireplace may ignite flooring or concealed combustible surfaces.• Protective metal hearth strips MUST be installed.• Hearth extensions MUST be installed exactly as

specified.

Ahearthextensionmustbeinstalledwithallfireplacestoprotectthecombustiblefloorinfrontofthefireplacefrombothradiantheatandsparks.

• YouMUSTuseahearthextensionwiththisfireplace.

• RefertoFigure7.5forminimumdimensions.• Thisfireplacehasbeentestedandapprovedforusewith

ahearthextensioninsulatedtoaminimumRvalueof2.06.

• ThehearthextensionmaterialMUSTbecoveredwithtile,stoneorothernon-combustiblematerial.

• Manufactured hearthmaterials will usually have apublishedR value (resistance to heat) or k value (conductivityofheat).RefertotheformulainTable7.1toconvertakvaluetoanRvalue,

• Refer to Table 7.3 for hearth extension insulationalternatives.

Hearth Extension Insulation Alternatives, R Value = 2.06

Materialk per inch

thickr per inch

thick

Minimum thickness required

Hearth&HomeHX3,HX4 0.49 2.06 1 in.

USG Micore 300™ 0.49 2.06 1 in.

USG Durock™ Cement Board 1.92 0.52 4in.

Cement Mortar 5.0 0.20 101/2in.

Common Brick 5.0 0.20 101/2in.

Ceramic Tile 12.50 0.08 253/4in.

Armstrong™PrivacyGuardPlus 0.46 2.18 1 in.

Marble 14.3-20.0 0.07-0.05 29 1/2 - 41 1/4 in.

Anoncombustiblemantelmaybepositionednolowerthan46in.(1168mm)fromthebaseofthefireplace.

Noncombustible framingmaterialsmust be used abovethefireplacetoaheightof82in.(2083mm)ortotheceilingfromthebaseofthefireplaceforallconstructionmaterials,framingmembers,sheeting,andallfinishmaterials.

Figure 7.4 Mantel Specifications - Non-Combustible Mantel

46 in.(1168 mm)

Noncombustible Mantel

Clearances are from bottom of appliance to lower edge of mantel or trimAll construction materials, framing members, sheeting and finish materials MUST be noncombustible.

WARNING! Risk of Fire!

You must comply with all minimum air space clearances to combustibles as specified. Framing or finishing material used on the front of, or in front of, the fireplace closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc.). Failure to comply may cause fire.

36 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

8 in. (203mm) minimum from each side offuel opening

AB

Figure 7.5 Minimum Hearth Extension Dimensions

Model # 7100FP A Bin. 41 20mm 1041 508

• FireplaceandHearthExtensionflushonthefloor Non-combustibleflooringaminimumof20in.(508mm)

infrontofand8in.(203mm)toeithersideofthefuelopeningisrequiredasshowninFigure7.5.

The construction of, and materials used for a hearth extension are shown in Figure 7.6. A hearth extension of this constructionmay be coveredwith any non-combustible decorativematerial andmay have aminimumthicknessasperFigure7.6.Sealgapsbetweenthehearthextensionandthefrontofthefireplacewithabeadofnon-combustiblesealantorgrout.

FasciaOuter Can Flange

Protective metalhearth strip

Tile,marble or other non-combustible finish material

Minimum 4 in. (102 mm) Cement Board or equivalent, (or two pieces HX4)

Minimum 20 in. (508mm) in front and 8 in. (203mm) on sides to fuel opening

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . .

. . .

. . .

. .

Non-combustible material supplied with unit.

. . .

. . .

. . .

. .

Non-combustible sealant or groutTile,marble or other non-combustible finish material

Figure 7.6 Fireplace and Hearth Extension Flush on the Floor.

• RaisedHearthExtensionFraming The hearth framing must be constructed of non-

combustible materials (such as metal framing orequivalentmaterial) and toppedwith twoHX4s, orequivalentmaterial(Table7.3).

When creating the platform, allow for the thickness of the non-combustible finishing materials (Figure7.7).

Outer Can Flange

Non-combustible material supplied with unit

Fascia

Protective metalhearth strip

Minimum 4 in. (102 mm) Cement Board or equivalent, (or two pieces HX4)

Minimum 20 in. (508 mm) in front and 8 in. (203 mm) on sides to fuel opening

Combustible Floor

Non-combustible sealant or groutTile,marble or other non-combustible finish material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

. . .

. . .

. .

. . .

. . .

. . .

. .

Non-combustibleframing materials

Figure 7.7 Raised Hearth Extension to Bottom of Fascia

• Fireplaceinstalledflushonthefloorandhearthextensionraisedtobottomoffascia:

Non-combustibleflooringaminimumof20in.(508mm)infrontofand8in.(203mm)toeithersideofthefuelopeningisrequired(seeFigure7.4).

WARNING! Risk of Fire!

Hearth extensions are to be installed only as illustrated to prevent high tempertures from occurring on concealed combustible materials.

37Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

E. Non-Combustible Sealant Material• After completing the installation of non-combustible

materialintherequirednon-combustiblezoneandthenon-combustiblefinishingmaterialoverthat,removethetemplate.

• Abeadofnon-combustiblesealant(orSuperCalstick)mustbeusedtocloseoffanygapsatthetopandsidesbetween the fireplace and non-combustible facing(Figure7.6)topreventcoldairleaksandtheriskoffire.Largegapscanbebridgedwithfiberglassropegasket.

• Wheninstallationofthedecorativematerialiscomplete,replace/installthefasciaandfireplacedoors.

WARNING! Risk of Fire! • Maintain clearances. • Use only non-combustible material below standoffs,

material such as cement board is acceptable. • Framing or finishing material used on the front of

the fireplace closer than the minimums listed, must be constructed entirely of non-combustible materi-als (i.e., steel studs, concrete board, etc.).

WARNING! Risk of Fire! Hearth & Home Technologies is not responsible for

discoloration, cracking or other material failures of finishing materials due to heat exposure or smoke.

• Choose finishing materials carefully.

Seal inside perimeter of fireplace finished opening with non-combustible grout to prevent risk of fire and cold air infiltration.

7100

45-1/4 in.(1150 mm)

47-1/2 in.(1207 mm)

NON-COMBUSTIBLE ZONE

Figure 7.6

WARNING! Risk of Fire! Seal around finishing material to fireplace.

38 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

8 Fireplace Setup

A. Firebrick PlacementThefireboxofyourfireplaceislinedwithhighqualityfire-brick,whichhasexceptionalinsulatingproperties.

Donotuseagrate;simplybuildafireonthefireboxfloor.

Donotoperatethefireplacewithoutbricks.Makesurebricksareinstalledasshown.

IMPORTANT:Thebricksareverysimilarinsize.Becertainyouhavetheproperbrickinthecorrectlocation.Measurethebricksizeforaccuracy.

- Remove new brick set from box and lay out todiagram as shown in Figure 8.2.

- Laybottombricksinfirebox.- Install rearbrickson the topof thebottombricks.

Slidetopofbricksundercliponbackoffireboxwallandpushbottomofbrickback.

- Installsidebricks.Slidetopofbrickunderclipsonsideoffireboxandpushthebottomofthebrickuntilitisflushwiththesideofthefirebox.

4

5 5 5 5 5 5

5

5

3

5 5 5 5 5

222224

5

5

5

3

11

5 5 5 5 5

5 5 5 5 5 11

4 2 2 2 2 2 4

5

5

5

3

5

5

5

3

Left Side Right SideBack

Floor

1-1/4"3-1/4"

9.0"

1

# Brick Size Qty. In Set1 9”x3-1/4”x1-1/4”Angled(see drawing) 22 6-1/4”x4-1/2”x1-1/4” 53 9”x2”x1-1/4” 24 6-1/4”x3-1/2”x1-1/4” 25 9”x4.5”x1-1/4” 16

Figure 8.1 Fire Brick Configurations

Figure 8.2 Fire Brick Configurations

Table 8.1

39Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

B. Baffle and Blanket PlacementEnsurecorrectbaffleandbaffleprotectionchannelplace-ment;replacebafflecomponentsifdamagedormissing.

TheceramicblanketandbaffleboardMUSTbeincontactwiththebackofthefireboxandevenwitheachotherinthe front.ThebaffleprotectionchannelMUSTbeinposi-tion.

Figure 8.3

Ceramic BlanketBack of Firebox

Baffle Board

Baffle Protection Channel in position

C. Install Fascia (Fronts)Frontsarerequiredtocompletetheinstallation.The7100fireplaceallowsachoiceoffronts,thereforetheyareshippedseparatelyfromthefireplaceduetocustomerpreference and selection. Instructions for attachment of the fronts are included with them. Contact your local dealerwithanyquestionsonofferingsorinstallation.

40 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

A. Chimney ComponentsThefollowingdrawingsshowtheSL-300Serieschimneyandfireplacecomponentswhichmaybesafelyusedwiththisfireplace.The8in.DuraPluscanalsobeused.

ID4 Insulated Duct

UD4 Uninsulated Duct

42 in. (1067 mm)

4 in. (102 mm) i.d.

42 in.(1067 mm)

4 in. (102 mm) i.d.

8 in.(203 mm)

10-1/2 in.(267 mm)

A

B

10-1/2 in.(287 mm)

12 in.(305 mm)

5-1/4 in.(133 mm) 4 in. (102 mm)

12 in.(305 mm)

CAK4A Chimney Air Kit (shipped with fireplace)

Catalog #A B

in mm in mmSL306 6 152 4-3/4 121

SL312 12 305 10-3/4 273

SL318 18 457 16-3/4 425

SL324 24 610 22-3/4 578

SL336 36 914 34-3/4 883

SL348 48 1219 46-3/4 1187

9 Reference Materials

Catalog # DescriptionCAK4A ChimneyAirKit(shippedwithfireplace)

ID4 InsulatedDuct(usedwithchimneyairkit)

UD4 UninsulatedDuct(usedwthchimneyairkit)

SL306 ChimneySection-6in.(152mm)long

SL312 ChimneySection-12in.(305mm)long

SL318 ChimneySection-18in.(457mm)long

SL324 ChimneySection-24in.(610mm)long

SL336 ChimneySection-36in.(914mm)long

SL348 ChimneySection-48in.(1219mm)long

SL3 ChimneyStabilizer

SL315 ChimneyOffset/Return-15deg

SL330 ChimneyOffset/Return-30deg

FS338 Ceiling Firestop - Straight

FS339 CeilingFirestop-15deg

FS340 Ceiling Firestop - 30 deg

AS8 SL300StraightAtticInsulationShield,24in.(610mm)(shippedwithfireplace)

JB877 Chimney Joint Band

CB876 Chimney Bracket

RF370 RoofFlashing-Flatto6/12Pitch

RF371 RoofFlashing-6/12to12/12Pitch

DTO134/146 OctogonalDecorativeCaps

DTS134/146 SquareDecorativeCaps

ST375 SquareTerminationCap

TCT375 Terra Cotta Termination Cap

TR344 Round Termination Cap

TR342-B Round Telescoping Termination Cap

TR-TVK TR Top Vent Kit

TS345 SquareTerminationCap

TS345P SquareTerminationCap-Painted

12966A ManufacturedHomeThimble

MH841 ManufacturedHomeThimbleExtension20in./508mm

HX4 MicoreHearthExtension,20in./508mmwide

LDS33 DecorativeShroud-3ftx3ft(.91mx.91m)

LDS46 DecorativeShroud-4ftx6ft(1.22mx1.83m)

LDS-BV DecorativeShroud-26in.x26in.(660mmx660mm)

FieldConstructedShrouds(See“WoodburningTerminationCap”)

CT-3A-B Adapter-Maybeusedwiththefollowingcaps

CT Series

DT Series

8DP-BP DuraplusBasePlate(requiredifusingDuraPlusChimney)

41Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

RF370 - Roof Flashing Flat to 6/12 Pitch

RF371 - Roof Flashing 6/12 to 12/12 Pitch

Firestop Spacer

A = Actual LengthB=Effectivelength(lengthofchimneypart

afterithasbeensnappedtoanother)

A

B 14-1/2 in.(368 mm)

24-5/8 in.(625 mm)

27-3/8 in.(695 mm)

12 in.(305 mm)

31 in.(787 mm)

24-5/8 in.(625 mm)

12 in.(305 mm)

Catalog # A BFS338 0-deg. 14-1/2in. 368 mm

FS339 15-deg. 18-3/8in. 467mm

FS340 30-deg. 23 in. 584mm

20-3/4 in.(527 mm)

InsideDiameter

8 in.(203 mm)

OutsideDiameter10-1/2 in.(267 mm)

4-3/4 in. (121 mm)Effective Height

SL3 Chimney Stabilizer

AS8 SL300 Straight Attic Insulation Shield (shipped with unit)

2 in. (51 mm)

10-1/2 in.(267 mm)

JB877 Chimney Joint Band

10-1/2 in.(267 mm)

CB876 Chimney Bracket

MH841 Manufactured Home Thimble Extension

24-5/8 in.(625 mm)

16-5/8 in.(422 mm)

29 in.(737 mm)

16-5/8 in.(422 mm)

12966A Manufactured Home ThimbleAssembled

Diameter: 14 1/2 in./368 mmHeight: 24 in./610 mm

20 in.(508 mm)

66 in.(1676 mm)

1/2 in.(13 mm)

HX4 Micore Hearth Extension

InsideDiameter

8 in. (203 mm)

OutsideDiameter10-1/2 in.(267 mm)

SL315 Chimney Offset/Return - Effective Height 13-3/8in. (380 mm)SL330 Chimney Offset/Return - Effective Height 15-1/2in. (394 mm)

42 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

B

A

C

B

C

A

DTS134/DTS146 DTO134/DTO146Decorative Caps

DTO134 A B Cin 34 20 24mm 864 508 610

DTO146in 46 22.7 26mm 1168 576 660

DTS134 A B Cin 34 21.18 24mm 864 538 610

DTS146in 46 21.18 26mm 1168 538 660

15-3/4 in.(400 mm)

TR344 Round Termination Cap

TCT375 Terra Cotta Cap

TR342-B Round Telescoping Termination Cap

ST375 Square Termination Cap

43Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

TR-TVK Top Vent Kit

A

B

C

D

Catalog #A B C D

in. mm in. mm in. mm in. mmLDS33 36 914 36 914 8.5 216 11 279

LDS46 48 1219 72 1829 8.5 216 11 279

LDS33/LDS46 Decorative Shroud

Catalog # A B C D E

LDS-BVin. 26 12.5 15.5 22 23

mm 660 318 394 533 584

ED

A

CB

LDS-BV Decorative Shroud

TS345/TS345P Square Termination Cap

CT-3-B

44 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

B. Accessories

Fronts (Required to Complete)Mission Hill FrontDF-7100MH-B MissionHillfront,classicblacksmoothfinishRolling Meadows FrontDF-7100RM RollingMeadowsFront,classicblacksmoothfinishDF-7100RM-NL RollingMeadowsFront,classicblacksmoothfinishValley Forge FrontDF-7100VF-B ValleyForgefront,classicblackhammeredfinish

FirescreensSCR-433 FirescreenLintel BarLINTEL-433 LintelBarFinishing TemplateTMP-433 MetalFinishingTemplate

45Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

This page intentionally left blank.

46 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18

Quadra-Fire,abrandofHearth&HomeTechnologies1915WestSaundersStreet,MountPleasant,Iowa52641

www.quadrafire.com

PleasecontactyourQuadra-Firedealerwithanyquestionsorconcerns.ForthelocationofyournearestQuadra-Firedealer,pleasevisitwww.quadrafire.com.

47Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev Q • 01/18