Page1of11
InstallationInstructionsEngineeredHardwoodHDFFlooringDocumentID#:VBHF080116_ENGHDF
ContactCustomerServiceat844-358-0107withallyourTechnicalQuestionsProductsIncluded ApprovedGradeLevels ApprovedInstallationMethods
AllEngineeredHardwoodHDFwithclicklockjoints.
AboveGrade.OnGrade.BelowGrade
PrimaryMethod:Floating.OptionalMethod:FullSpreadGlue.
ApprovedGradeLevels
AboveGrade.OnGrade.BelowGrade
Owner/InstallerResponsibilityTheownerisadvisedtobeathomeduringtheinstallationforconsultation/direction. Theownerandinstallershoulddiscussinstallationand layouttomaximizesatisfaction. Ifthisisnotpossible,consultationshouldbedonepriortoinstallation.Installersshouldbefamiliarwith installationguidelinesfromNationalWoodFlooringAssociation(woodfloors.org).
Theowner/installerassumesallresponsibilityforproductqualityofcompletedinstallation.PERFORMPRE-INSTALLINSPECTION. FORCLAIMSPURPOSES,YOUAREALLOWEDTOOPENUPTO2BOXESFORPRODUCTINSPECTION. DONOTOPENALLTHEBOXES. OPENINGALLTHEBOXESCONSTITUTESYOURACCEPTANCEOFTHEPRODUCT. INSPECTALLTHEPLANKSINTHESE4BOXESCAREFULLY.EXAMINEFLOORINGFORCOLOR,FINISHANDQUALITY. IFYOUDISCOVERTHATPRODUCTSAREDEFECTIVE,ORIFMATERIALISQUESTIONABLE,YOU SHOULDCONTACTTHERETAILER. IFYOUARESATISFIED,PROCEEDWITHINSTALLATION.
Thelengthoftheeachplankinanyboxcanvaryfrom12inchestothemaximumfulllengthstatedonthepackagingorotherproductdescriptions. Eachboxcancontainallfulllengthboardsoracombinationoffulllengthandshorterboards. Thereisnospecificpercentageof productlengthdistribution.
Priortoinstallation,rackupplanksfromseveralboxestoensureuniformdistributionofcolors,shadesandcharactersintheinstalledflooring. Plankshavingsimilarwidthsshouldbeplacedtogetherinthesamerowtominimizegapsbetweenboards.
Woodfloorsarenaturalproductscontainingnaturalvariations. Variationsincolor,tone,grain,mineralstreaks,smallknotsandothercharactersarefoundfromplanktoplank. Similarvariationsexistbetweensamples,picturesandpurchasedflooring. Theyarenormalandit doesnotmeantheproductisdefective.
Flooringtobeinstalledinonelargeareashouldbepurchasedatthesametime. Productpurchasedatalatertimethanthefirstpurchase mayvarybeyondyourexpectations.
Accessories,trimsandmoldingsaremanufacturedtocoordinatewiththevariedappearancesofthefloorplanks. Anyexactmatchesare coincidental. Non-matchingaccessoriesarenotdefectiveproducts.
PROPOSITION65WARNING:ThisproductcontainschemicalsknowntothestateofCaliforniatocausecancerand/or reproductiveharm
CAUTION:ASBESTOSINEXISTINGFLOORHome Modern product does not contain asbestos. Existing installed resilient flooring and asphaltic adhesive may containasbestos fillers or crystalline silica. Do not sand, dry sweep, dry scrape, drill, saw, bead-blast, or mechanically chip orpulverize existing resilient flooring, backing, lining felt, asphaltic “cutback” adhesive or other adhesive. See“Recommended Work Practices for Removal of ResilientFloorCoverings”(rfci.com)fordetailedinformationandinstructionsonremovingallresilientcoveringstructures.
CAUTION:WOODDUSTSawing,sandingandmachiningwoodproductscanproducewooddust. It cancauserespiratory,skinandeye irritation. Avoidprolonged exposure to wood dust. Power tools should be equipped with a dust collector. If possible, perform wood dustgeneratingactivities outdoors. IfhighdustlevelsareencountereduseanappropriateNIOSH-designateddustmask.
Page2of11
Thisproductismanufacturedaccordingtostrictqualitystandards. Intheeventthatdefectsarediscoveredinthefield,theindustry standardspermitadefecttolerancenottoexceed5%. Thedefectsmaybeofanytype,whethermanufacturedornatural. Orderan additional5%extraforcuttingwastageandgradingallowances(10%fordiagonalinstallations).
Duringinstallation,inspecttheplankscontinuously. Defectsthatcanbeseenfromastandingpositionshouldbecutofforheldout.Installingdefectiveplanksimpliesacceptance.Squeakingandclickingnoisesaretheresultofinteractionsamongflooring,joistsandsubfloorswhentheymove. Limitingthemovementsof theflooringsystemusuallyeliminatesmostofthesenoises. Sometimes,itisimpossibletoeliminatethemcompletelyandminorsqueaking orclickingnoisesaretobeacceptedasnormalflooringphenomenon. Minorscratchescangenerallyberepairedwiththeuseofputty,stain orfiller. Itisanindustrystandardpracticeofflooringinstallationanditshouldbeacceptedasnormalbythehomeowner.
Toassurethewarrantyisnotinadvertentlyvoided,beforeproceedingwithanyactivitythatisnotcoveredinthismanual,pleasecontactour TechnicalSupportDepartment.CallTollFree844-358-0107
AcclimationandIn-serviceConditionsAcclimationistheprocessofadjusting(conditioning)themoisturecontentofhardwoodflooringtotheenvironmentinwhichitisexpected toperform. Thehardwoodflooringisfullyacclimatedwhenitsmoisturecontentanddimensions(widthandlength)arestable.Engineered hardwoodflooringtypicallydoesnotneedacclimationaslongastheenvironmentitisbeinginstalledinisfullyacclimated.ThismeanstheHVACsystemisfullyoperationalandthehomeisbeingmaintainedinlivedinconditionsduringandaftertheinstallation.Ifthetemperatureandrelativehumidityfallsoutsidenormalrangesof 60°F-80°Fandrelativehumidity(RH)of30%-50%thentheproductmustbeacclimatedforaminimumof3daysorlongerdependingonconditions.Tproperlyacclimateyoumust openboxes,openplasticwrap. Elevatecartonsfromthefloorbyplacingthemon2”X2”lumberorequivalence. Placespacers(3/4”to1”sticks)betweeneachlayeror crossstackthelayersformaximumexposuretoambientconditions. Acclimationtemperaturerangeis60°F-80°Fandrelativehumidity(RH)of30%-50%. Conditionsinwhichthefloorwasacclimatedshouldbemaintainedcontinuouslythereafter. Documentasmuchacclimation informationaspossiblebelow.Date: RelativeHumidity(%):_ Temperature(°F): SubfloorType: Subfloor Avg.MoistureContent(%): Acclimation Period:
Pre-acclimationFlooringAvg.MoistureContent(%): Pre-acclimationFlooringWidth:_______Pre-acclimationFlooringLength:_______
Post-acclimationFlooringAvg.MoistureContent(%): Post-acclimationFlooringWidth:_____Post-acclimationFlooringLength:____
JobSiteCondition
Priortoinstallation,theinstallermustensurethatatthetimeofinstallation,thejobsiteconditionsincludingsubfloor/substrate,ambient temperatureandrelativehumidity,andallimpactingvariableswillnotnegativelyaffectfloor. HomeModernwilldeclineresponsibilityfor damagesassociatedwithimproperinstallationorpoorsiteconditions.
StorageandConditions
Donotstoreflooringinuncontrolledenvironmentalconditions. Forexample,garagesandexteriorpatiosarenotacceptableareastostore flooring. Handleandunloadwoodflooringwithcareandstorewithintheenvironmentallycontrolledsiteinwhichitisexpectedtoperform. Flooringstoredonconcreteslabshouldbeelevatedatleastfourinchestoallowaircirculationundercartons.
ExistingHome
Existinghomeshouldhaveaconsistentroomtemperatureof60°F-80°Fandrelativehumidity(RH)of30%-50%. Continualdeviationfrom theseconditionswillaffectthedimensionsofflooring. Duringheatingseason,humiditymaybemuchlowerthantheacceptablerange. Duringheatingseason,ahumidifierisrecommendedtopreventexcessshrinkageflooringtolowhumiditylevels.Duringthenon-heating season,humiditylevelscanbemaintainedbyusinganairconditioner,dehumidifier,orbyturningonyourheatingsystemperiodically.
NewConstructionorRemodel
Allworkinvolvingwater,suchaspouringbasementconcretefloors,drywallandplasterwork,plumbing,etc.mustbecompletedwellin advanceofthefloordelivery. Ensurethatthebuildingisenclosed. Wherebuildingcodesallow,permanentheatingand/orairconditioning systemsshouldbeoperatingatleastfivedaysprecedinginstallationtopromoteproperacclimationandshouldbemaintainedduringandafter installation. Ifitisnotpossibleforthepermanentheatingand/orairconditioningsystemtobeoperatingbefore,duringandafterinstallation, atemporaryheatingand/ordehumidificationsystemthatsimulatenormalliving(occupied)conditionscanenabletheinstallationtoproceeduntilthepermanentheatingand/orairconditioningsystemisfullyoperational.
Page3of11
Yourjobsiteshouldhaveaconsistenttemperatureof60°F-80°Fandrelativehumidity(RH)of30%-50%whichshouldbemaintainedcontinuouslythereafter.
BasementsandCrawlSpaces
Concreteslaborgroundmustbedry. Thegroundinthecrawlspacesmustbecompletelycoveredusing6milblackpolyethylene.Crawl spaceclearancebetweentheearthandundersideofjoistsshouldbenolessthan18inchesandtheperimeterventareashouldbeequalto1.5%ofthetotalsquarefootageofthecrawlspaceorasmandatedbycode.
ConcreteSubfloorRequirements
Itmusthaveminimumratedstrengthof3000psi.
Itmustbeflat. Itshouldbeflattowithin1/8”ina6-footspan;nobumpsorlowspots. Highspotscanberemovedbygrinding;depressions canbefilledwithpatchingcompoundformulatedforuseinfloorinstallation.
Itmustbeclean;noconstructiondebris,soil,mudandanyotherobjectson/oradheringtothefloor;ifnecessary,scrapeandsweepaway beforetheinstallation;noprotrusionsofnails,debris,metalsshouldremain.
Newconcreteslabmustcureforatleast60days. Itmusthaveaminimum10-milpolyethylenesheetbetweenthegroundandtheconcrete. Itmustmeetconcretemoisturerequirementbelow.
Itmustbefreefrommoisturerelatedconditionswhichcandamagetheinstalledflooring.
LightWeightConcrete
Itisconcretewhichratedstrengthislessthan3000psi.
Performaquickcheckbydrawinganailacrossthetop;ifitleavesindentation,itisprobablylightconcrete.
Forglue-downapplication,theconcretemustpossessshearstrengthgreaterthantheglue. Ifconcreteratedpsiisunknown,contactthe adhesivemanufacturerforguidance.
ConcreteMoisture
Allconcretesubfloorsshouldbetestedformoisturecontentandtheresultsdocumented. Visualchecksarenotreliable. Performtestsat locationsaroundexteriordoorways,nearwallscontainingplumbing,nearfoundationwallsandinthecenteroftheroom.Minimumsample sizeis3per1000squarefeetofareaandonetestforeveryadditional1000squarefeetthereafter.Itsmoisturecontentshouldmeetoneofthefollowingcriteriabelow:• 4.5%whentestedusingTramexConcreteMoistureEncounter
• Lessthan3poundsper1000squarefeetper24hourswhenusingCalciumChloridetest(ASTMF1869)• 75%whenusingRelativeHumidityTesting(ASTMF-2170).Pleasenote: Concretemoisturecontentmaybeacceptablethetimeofthetestbutthesetestsdonotguaranteeaperpetual“dry”concrete slab. Theconcreteslabmoisturecontentcanvaryatothertimesoftheyear.Wearenotresponsibleformoisturerelateddamagetoinstalled flooring.
WoodSubfloorRequirements
Itmustbeclean;nopresenceofconstructiondebris,soil,mudandanyotherobjectsonoradheringtothefloor;noprotrusionsofnails, debris,metalsshouldremain. Ifnecessary,scrapeandsweepthesubfloorbeforetheinstallation.
Itmustbestructurallysoundandstable:nomovementsorsqueaks,noloosepanelsorloosenails,nosignsofplyde-laminationorother damages. Repairallshortcomingsbeforeinstallation.
Itmustbeflatwithnovisiblebumpsorlowspots;thesubfloorshouldbeflattowithin1/8”in6feetspan.
Testformoistureusingreliablemoisturemeter. Performtestsatlocationsaroundexteriordoorways,nearfoundationwalls,nearwallscontainingplumbinglinesandinthecenteroftheroom. Measure20locationsper1000squarefeet.
Moisturecontentofsubfloorshouldbelessthan12%.
Moisturecontentdifferencebetweensubfloorandacclimatedflooringshouldbe4%orless.
PlywoodorOrientedStrandBoard(OSB)Specifications
Ontruss/joistspacingof16”(406mm)O/Corless,theindustrystandardforsingle-panelsubflooringisminimum5/8”(19/32”,15.1mm)CDExposure1plywoodsubfloorpanels(CDExposure1)or23/32”OSBExposure1subfloorpanels,4’x8'sheets. Expansiongapbetweenpanels shouldbe1/8”(3mm). Ifpanelsarenottonguedandgroovedandthereisnotsufficientspacingorisinadequate,cutintherequiredspacingwithacircularsaw.Donotcutinexpansionspaceontongueandgroovepanels.Iftruss/joistspacingis19.2"apartthenminimumthickness ofplywoodorOSBpanelsis23/32".Iftruss/joistspacingislargerthan19.2"apartthenminimumplywoodthicknessis1"andminimumthicknessforOSBis1.125".Ifthesubstratedoesnotmeettheseminimumguidelinesthenadd1/2"ofplywoodtothesubstratebeforeproceeding
ParticleBoardorFiberBoard
Page4of11
Onlyforfloatinginstallation.
ExistingFloors
Installationoverexistingfloorrequirestheinstallertoconsiderpotentialissuesrelatedtomoisturedamage,adhesive failureandfastener failure. Contacttheadhesiveandfastenermanufacturersrespectivelyfortheirspecificinstructions,recommendationsandrequirements. Acceptable floor coverings include: solid hardwood, linoleum, terrazzo, ceramic tile and other “moisture sealingfloors.”
Unacceptablefloorcoveringsinclude:carpet,needlepunchfelt,edgegluedlinoleumandother“moistureabsorbingflooring.”
RadiantHeatedSubfloor
Thisproductcanbeinstalledoverradiantheatedsubfloor. Operatingsurfacetemperaturemustbelessthan82°F. Decreasetemperaturebeforeinstallation. Increasetemperaturegraduallyafterinstallation. Gluedowninstallationmayrequireadditionalinstallationrequirement.Contactgluemanufacturerforspecificrecommendation. Contactheatermanufacturerforspecificinstallationinstruction.
MoistureBarrierandMoistureRetarder
ConcreteSubfloor: Forfloatinginstallation,use6-milpolyethylenefilmorothermeanswithequivalentpermeability. Overlaptheedge seamsandtapeittogether. Extendmoisturebarrieruptothewallabout1inchhigh. Wheninstalledonabovegradeconcreteandthe concretemoisturecontentmeetstheconcretemoisturestandard,amoisturebarrierisnotrequired. Fordirectglueinstallation,useamoisturebarrierifmoisturelevelexceedsrequirement(seeConcreteMoisturesectionabove).
WoodSubfloor: Useasphalt-saturatedpaperor#15or#30feltthatmeetsASTMStandardD4869orUU-B-790,GradeD.Overlapalongtheedgeseams2”-4”wide. Thisretardsmoisturemovementfrombelow.
SoundControlUnderlayment
Checkwithsoundcontrolmanufacturerforapplicationguidelines. Generally,thelesscompressiveunderlaymentispreferred.
ExpansionGap
Requiredgapwidthis1/2”. Itisrequiredaroundtheperimeterofthefloorandbetweenfloorandallverticalobstructions.Donotplacepermanentlyinstalledstructuressuchaskitchencounter/cabinetontheinstalledfloor.
TransitionMoldingFloatinginstallation,transitionT-moldingisrequiredinthefollowingcases:floorspanninggreaterthan35feetinlengthorwidth;wallopenings-withorwithoutdoor;
Note:Floorareasinterruptedbywallsectionsextendingoutofthewall;floorareaswhicharenotrectangularmayexperiencebucklingor gappingifthereisexcessivefloorexpansionorshrinkage.
Adhesive
Usepremiumflooringadhesivewhichisnon-waterbased,formulatedforhardwoodflooringinstallation.Preferredtype:moisturecureurethanefloorglue.
ToolsandMaterials
Basics:
Tapemeasure•Moisturemeter(wood,concreteorboth)•Chalkline&chalk•Hammer•Electricpowersaw•Carbidetippedsawbladefor finecut•NIOSH-designateddustmask•Handsaworjambsaw•Eyeprotection•StraightedgeorSpacers•PryBar•Mallet•Broom•Colormatchedwoodputty•Tappingblock•Pullbar
AdditionalSuppliesforGlue-DownMethod:
Flooringadhesive•Trowels•Adhesiveremoverforselectedadhesive•Cleanrags•Weightroller•3MBluetape
BondFailure
BondfailureisNOTflooringproductdefect. Mostinstallationfailures,includingbondfailure,resultfromjobsitemoisture. Donotunpackor deliverflooringtothejobsiteuntilmoistureproblemsarecorrected. Readadhesivemanufacturer’sinstructioncarefully.Certainwood flooringadhesivesmayhavespecialrequirementsandlimitationsofuse. Someexistingfloormaynotbeacceptable.
SafetyandHealthPrecautionsPowertoolscanbedangerous. Operateinstrictaccordancetomanufacturer’soperatinginstructionsandsafetyprecautions.Unsafeand improperusecancauseseriousinjuries.Avoidinhalationandexposurestowooddustbymechanicalmeansandbywearingpersonalprotectiveequipment.Wearappropriatepersonalprotectiveequipment(PPE)whichincludeNIOSHorOSHAapprovedustmasks,safetygoggleandworkgloves.
Page5of11
Notfollowingthe adhesivemanufacturer’srecommendationscanleadtoinstallationfailureorproductdamageandwillvoidyourwarranty.
GlueSpotsonFaceofFinishedFloor
Adhesivecandamagethefloor’sfinish,especiallywhenithasdried. ItisextremelyimportanttotakeprecautionarystepsNOTtoleavefinger printsorfootprintsmarksonthefaceoftheboard. Ifgluecomesincontactwiththefaceoftheboard,removeimmediatelywiththeadhesive removerrecommendedbytheadhesivemanufacturer. Usecleantowels,changingfrequentlytopreventhazeandadhesiveresidue.Ifthespotremovaldamagestheappearanceoftheboards,replacetheboard.
HelpfulPointersGeneralTips• Makesureyourworkareaiswelllit. Goodvisibilityensuresthatcolorisconsistentandthatvisuallydefectiveplanksaredetectedand removed.
• Theminimumlengthofthefirstandlastplankis12”. Ifthelastplankwillbelessthan12”,adjustthelengthofthefirstplank. The remainderofthelastplankcanbeusedasastarterboardonthefollowingrows.
• Usingashorterpieceatundercutdoorjamswillhelpwhenfittingflooringinplace.Glue-DownInstallationTips• ALWAYSREFERTOTHESPECIFICINSTRUCTIONSONTHEFLOORINGADHESIVELABEL. Theinformationgivenhereisfortypicalinstallation. Adjustitaccordingtoadhesivemanufacturer’sinstruction.
• Dry-laymeansthegluehastosetbeforeplacingfloorplanksinit. Wet-laymeansthegluedoesnotneedtosetbeforeplacingflooronit.
• Usetrowelasspecifiedbyadhesivemanufacturer.• ContinuouslycheckthetransferofadhesiveTHROUGHOUTtheinstallationprocess. Iftheadhesivenolongertransferstothebackofthe flooringmaterial,itmustberemovedandnewadhesiveapplied.
• Workyourwayoutoftheroom.• Aftertheinstallationiscompleted,keepthefloorfreefromdailyfoottrafficforaminimumof24hourstoallowadhesivetoproperlycure.
CuttingtheLastRowtoWidth• Mostoftentheentirelengthofthelastrowwillneedtobecutsothatitisnarrowenoughtofittheremainingspace.• Measurethedistancebetweenthefloorfaceedge(excludethetongue)tothewall. Subtract1/2“fromthismeasurementforexpansion gap. Drawaline. Cutthroughtheline. Discardtheexcesspiece. Proceedwithinstallation.
Pre-InstallActivities
• Subfloorsshouldbeincleancondition.• Understandthepartsofthelockingpartoftheflooringplank. Thetongueisthethinnerextensioncomingoutofthesideofthe planks. Thegrooveisthewiderextensioncomingoutoftheothersideofthefloorplank. Theendsdonothavetongueandgroove. Thereisanupperdrop-lockendononesideandalower-droplockendontheotherside.
• Layoutseveralcartons. Randomlyrackplankstoensuregoodcolorandshademixtureandendjointspacing. Minimumendstagger is6”. Inspectplankqualityandgrading.
• Layouttrimmoldingsinadvanceandfindplankswhoseshadecloselymatches. Settheseasideforfutureuse.• Removeexistingbase,shoemoldingorthresholdcarefully.Theycanbeusedtocoverthe1/2”expansiongapleftaroundtheedgeof theroom.
• Undercutdoorsandcasingsusingahandsawlaidflatonapieceofscrapflooring.
Page6of11
• Installmoisturebarrieronconcrete. Forconcrete,letthemoisturebarrierrunupthewallabitbeforecuttingtosizeandtapeall seams
• Installtheunderlayment(ifused)accordingtounderlaymentmanufactureinstructions.
ContactCustomerServiceTollFreeat844-358-0107withallyourTechnicalQuestions
FloatingInstallation
Step1–InstalltheFirstRow• Whenpossible,begininstallationfromthestraightestwall. Ifpossible,installtheflooringperpendiculartothejoists.• Cutoffthetonguefromthefirstrowplanks.• Allow1/2”expansiongapbetweenplankandthewalls. Usespacersorboard.• Placethefirstplankwiththegroovesidefacingawayfromthewalls.• Placetheupperdrop-lockendofthesecondplankonthelowerdrop-lockendofthefirstplank. Theendsdonotclicklock.Maintain straightedgealongtherows.
• Continueplacingthesucceedingplankstocompletetherow
Page7of11
Step2–InstalltheSecondandRemainingRows• Cutoffasectionthefirstplanklengthwisetoensure6”jointsstaggering.• Holdtheplankwiththetonguefacingthepreviousrow. Keepitatabout30°angle.• Insertthetongueintothegroove.• Makesurethetonguearesnugglyandsecurelyengagedinthegroovebyexertingaconstantpressureinthedirectionofthegroove.
• Maintainthepressurewhilepressingtheplankflattolocktheedgejoints.• Ifthereisaslightgapalongtheedgejoints,itcanbeeliminatedwiththehelpofatappingblockandaplasticmallet. Usecautionto preventimpactdamage.
Step3-InstalltheLastRow• Usethepullbartodrawthelastrowtofittightlytothepreviousrow.
GlueDownInstallation
PLEASENOTE:ANYEXCESSGLUEWHICHGETSONTOTHESURFACEOFTHEFLOORMUSTBEREMOVEDIMMEDIATELYWITHADHESIVEREMOVER
Thestepsingluedownmethodareverysimilartothefloatinginstallationmethod. Theonlydifferenceistheapplicationofthegluetothe subfloorpriortoinstallation. Formoredetailinstruction,seethefloatinginstallationsectionabove.
Step1–Setup• Cutoffthetonguefromthelongedgeoftheboardsforthefirstrows.• Ensureexpansiongapbymarkingoffastartingline1/2”awayfromthestartingwall. Markoffapproximately2plankswidthareato spreadglue.
Page8of11
Step2–Spreadingtheglue• Spreadthegluefromthestartinglineoutinthedirectionofthecenteroftheroom,thewidthoftwoplanks. Orspreadonlyenough gluetoinstallwhatcanbesetwithin45minutes(15minutesofOPENTIMEandanadditional30minutesforactualinstallation. Usuallyabouttworowswidthcoverage). Differentmanufacturermayrequiredifferentopentimeandsettime.Usespacersorboards tomaintainexpansiongapduringinstallation.
• Repeatwiththenexttworows,etc.
Step3–Installthefirsttworows• Installthefirstrowofstarterplanks.• Thelastplankofthefirstrowmayhavetobecuttosize. Discardremainderbecausethetonguehasbeenremoved.• Installthesecondrow. Makesurethereisarandomstaggeringattheendjointsofatleast6”apart.• Beattentivetostaggeringtheendsoftheboardscorrectlyinadjacentrowstoavoidclusteringendjoints.• Anygluethatcomesincontactwiththefaceoftheboardshouldberemovedimmediatelyusingadhesiveremoverformulatedforthe gluebeingused. Followadhesivemanufacturer’sinstructiononadhesiveremoval.
ContactCustomerServiceTollFreeat844-358-0107withallyourTechnicalQuestions
Step4–InstalltheremainingRowsSpreadanothersectionofglue. Neverspreadmorethatcanbecoveredbeforetheadhesiveisset. Ifadhesiveissetandwillnot transfertothebackoftheplank,scrapeofftheadhesiveandapplyfreshadhesive.Continuetoinstallthenextrows. Makesurethereisarandomstaggeringattheendjointsofatleast6”apart.Maintain1/2”expansiongapbetweenfloorandthewalls.Repeattheprocessforadditionalrows.Makesurethatthereis100%contactbetweenthewoodfloorandtheadhesive.
Page9of11
FinishingTouches
• Cleanthefloor.• Usematchingputtywherenecessary• Installorreinstallallwalltrimpieces. Nailthemthroughthewall,butnottothesubfloortoavoidrestrictingtheexpansiongap.• Installtransitiontrimpieces. Nailthemtothesubfloor,nottheflooring.• Atdoorways,transitionsshouldbeusedtoprotecttheedgesofthefloorandtoprovideadecorativetransitionfromonefloortypeto another.
• Iftheflooristobecovered,useabreathablematerialsuchascardboard. Donotcoverwithplastic.Donotapplyanytapetothefaceof theproductforprotectionoranyotherreasons.Finishdamagethatmayoccuristheresponsibilityofthepersonapplyingthetapeandisnotcoveredundertermsofthewarranty
Page10of11
ContactCustomerServiceTollFreeat844-358-0107withallyourTechnicalQuestions
AccessoriesPicturesareforgeneralillustrativepurposesonly.Actualproductsmaydifferfrompicture. T-Moldingisusedtocreateatransitionbetweenfloorcoveringsofsimilarheightsorto
coveran expansiongap.
StairNoseisusedinconjunctionwithflooringinstalledonstairstepsorfinishededgeofahigher levelfloorlikeinasunkenlivingroom.
CarpetReducer(alsocalledBabyThresholdorEndCap)isusedtotransitionfloorcoveringsof differingheights.Thisreducerstripisalsocommonlyusedtoborderafireplace,slidingglassdoor andotherexteriordoorjambs.
HardSurfaceReducerisusedtotransitiontoanotherhardsurfaceflooringofdifferentheights suchastile,vinyl,concrete.
QuarterRoundisusedtocovertheexpansionspacebetweentheWallBaseandyourflooring.It canalsobeusedthemtomakesmoothtransitionsbetweenthefloorandcabinetry. Itcanbeused withorwithoutWallBasemolding.
WallBaseisusedtogiveafinishedlookatthebaseofthewalls. Itcanbeusedwithorwithout QuarterRound.
TechnicalSupportForinstallationinformationandtechnicalquestionsnotcoveredinthisinstallationguide,pleasecontactourTechnicalSupportRepresentativebycallingthetollfreenumberbelow.
ContactCustomerServiceToolFreeat844-358-0107withallyourTechnicalQuestionsCareandMaintenanceDailyMaintenance1. Sweepdustmoporvacuumyourfloorregularlytoremoveanyparticlesthatcouldcauseabrasionorscratchyourfloor.CAUTION: Vacuumswithabeaterbarorpowerrotarybrushheadcandamageafloorandshouldneverbeused.
2. Applyappropriatecleaningsolutiontothecleaningcloth/mop. Useacleanerspecificallymanufacturedforhardwoodflooring.DoNotUseWaterorVinegar.DoNOTapplydirectlytothefloor.
• Fortougherspots,useahigherconcentrationofisopropylalcoholanddistilledwater.• Forextremecases,asolutionofnailpolishremover(acetone)anddistilledwatercanbeused.
HINT: Forbestresults,cleanthefloorinthesamedirectionoftheplanks. Whenthecleaningcloth/mopbecomessoiled,rinseorreplaceit withacleanone. Followingupwithaclean,dryclothwillremoveresidualstreakmarksandspots.
Page11of11
3. DoNOTleaveanyamountofliquids(water,juice,softdrinks,spills,etc.)onthefloor. Cleananywetspotsimmediately.4. DoNOTuseasteamcleaner.5. DoNOTuseawetmopordousefloorwithwaterorliquidcleaners.Liquidcanseepbetweenthecracksandcausemoisturedamage.6. DoNOTuseanycleaningagentscontainingwax,oilorpolish. Leftoverresiduewillformadullfilm.7. DoNOTusesteelwoolorscouringpowderwhichwillscratchthefloor.
BrandedorOff-the-shelfFloorCareProducts• Ifnoneoftheaboveareeffectiveandyouchoosetouseastoreboughtproduct,testtheproductinanon-conspicuousarea(i.e.,closet, corner,orscrappieces)forpotentialadversesideeffects.
PreventativeMaintenance• Protectyourfloorwhenusingadollyformovingfurnitureorappliances.Protectivesheetsand/orplywoodmaybeneeded.Neverslide orrollheavyfurnitureorappliancesacrossthefloor.
• Placeprotectivepadsbeneathfurniturelegsandotherheavyobjects.• Avoidexcessiveexposuretowaterfrombeingtrackedinduringperiodsofinclementweather.• Minimizeabrasivematerialanddirtbyplacingmatsonbothsidesofexteriordoorsandbyusingarearugsinhigh-trafficareas• Rearrangefurnitureandrugsperiodicallytoavoidunevencolorandshadechangesfromlightexposure.• Useprotectivematsbeneathrollingchairsandkeepfurniturecastersclean.• Keeppets’nailstrimmed.• Removeshoeswithcleats,spikesorexceptionallypointyheelsbeforewalkingonthefloor.
ClimateMaintenance• Careshouldbetakentocontrolhumiditylevelswithinthe30%-50%range. Hardwoodflooringcanbeaffectedbyvaryinglevelsof humidity.
• DryClimates:Ahumidifierisrecommendedtomaintainhumiditylevels. Woodstovesandelectricheattendtocreateverydry conditionsduringthewintermonthsthisalsowillcauseshrinkageinflooring.
• Humid,WetClimates: Byusinganairconditioner,heater,ordehumidifierproperhumiditylevelscanbemaintainedtoprevent excessiveexpansionduetohighmoisturecontent.
FloorRepair• Verylightandsmallsurfacescratchescanberepairedwithastaining“touchup”penoftheappropriatecolor.• Slightlydeeperscratchescanberepairedbymeansofcoloredputtyandorstains. Fillthescratcheswiththeputty. Levelwithputty knife. Wipeoffexcessputty.
• Verydeepscratchesmayrequirethereplacementoftheplanks.
ContactCustomerServiceTollFreeat844-358-0107withallyourTechnicalQuestions.