I N S T A L L A T I O N I N S T R U C T I O N SA D D E N D U M

Powered Suspended Ceiling Projector System

Spanish Product DescriptionGerman Product Description

Portuguese Product Description Italian Product DescriptionDutch Product Description

French Product Description

SYSAUxP2

Page 2: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

2

DISCLAIMERMilestone AV Technologies, and its affiliated corporations andsubsidiaries (collectively, "Milestone"), intend to make thismanual accurate and complete. However, Milestone makes noclaim that the information contained herein covers all details,conditions or variations, nor does it provide for every possiblecontingency in connection with the installation or use of thisproduct. The information contained in this document is subjectto change without notice or obligation of any kind. Milestonemakes no representation of warranty, expressed or implied,regarding the information contained herein. Milestone assumesno responsibility for accuracy, completeness or sufficiency ofthe information contained in this document.

Chief® is a registered trademark of Milestone AV Technologies.All rights reserved.

IMPORTANT SAFETY INSTRUCTIONS

WARNING alerts you to the possibility ofserious injury or death if you do not follow the instructions.

CAUTION alerts you to the possibility ofdamage or destruction of equipment if you do not follow thecorresponding instructions.

WARNING: FAILURE TO READ ANDFOLLOW THE FOLLOWING INSTRUCTIONS CAN RESULTIN SERIOUS PERSONAL INJURY, DAMAGE TO EQUIPMENTOR VOIDING OF FACTORY WARRANTY. It is the installer’sresponsibility to make sure all components are properlyassembled and installed using the instructions provided.

READ ALL INSTRUCTIONS BEFORE USING THISPRODUCT!!!!

DANGER: TO REDUCE THE RISK OFELECTRIC SHOCK:

1. Always turn off power at source before installing the outlet.

WARNING: TO REDUCE THE RISK OF

BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TOPERSONS:

• Always turn off power at source before servicing orremoving the outlet.

• Do not use outdoors - For indoor use only.• Route cables as shown in these installation

instructions.• To disconnect, turn off power at source.

WARNING: RISK OF ELECTRIC SHOCK!Make sure the outlet is properly grounded. See GroundingInstructions.

WARNING: Failure to provide adequatestructural strength for this outlet can result in serious personalinjury or damage to equipment! It is the installer’s responsibilityto make sure the structure to which this mount is attached cansupport the weight of the box.

CAUTION: Apparatus shall not be exposed todripping or splashing and no objects filled with liquids, such asvases, shall be placed on the apparatus.

CAUTION: This equipment must be installedand assembled by qualified service personnel in accordancewith local building and electrical codes.

NOTE: Knockouts are provided for ease of installation. Anyunused knockouts that have been punched are to beclosed up with a metal plug.

NOTE: Ambient Temperature - The manufacturer’s maximumambient temperature is 104°F (40°C) and minimumambient temperature is 30°F (-1°C) so that the installeris able to determine acceptability of use of Accessoriesand components.

--SAVE THESE INSTRUCTIONS--

Page 3: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

Installation Instructions SYSAUxP2

3

DIMENSIONS

DIMENSIONS: INCHES [MILLIMETERS]

*SEE

SYS

AU F

OR C

EILIN

G PL

ATE

DIME

NSIO

NS*

3.8

497

.5

3.9

910

1.4

MIN

7.09

180.2

MAX

16.50

419.1

5.2

513

3.4

4.5

011

4.3

ABO

VE TI

LE IN

STAL

LATIO

N

0.6

917

.6

3.7

394

.6

3.8

397

.3

AC L

INE

POW

ER C

ONDI

TION

ER 1

25 V

~, 6

0 Hz

, 15

A

4x14

AW

G ST

RAND

ED W

IRE

W/ I

SOLA

TED

GROU

ND

SURG

E PR

OTEC

TION

EMI/R

FI FI

LTER

ING

POW

ER C

ONSU

MPTI

ON: <

0.5 W

ATT

1/2"

-3/4

" CO

NDUI

T KNO

CKO

UTS (

16)

FLUS

H M

OUN

T INS

TALL

ATIO

N

0.2

5 6.2

0.2

56.3

3.6

692

.9

Page 4: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

4

LEGEND

TOOLS REQUIRED FOR INSTALLATION / PARTS

Tighten Fastener

Apretar elemento de fijación

Befestigungsteil festziehen

Apertar fixador

Serrare il fissaggio

Bevestiging vastdraaien

Serrez les fixations

Loosen Fastener

Aflojar elemento de fijación

Befestigungsteil lösen

Desapertar fixador

Allentare il fissaggio

Bevestiging losdraaien

Desserrez les fixations

Phillips Screwdriver

Destornillador Phillips

Kreuzschlitzschraubendreher

Chave de fendas Phillips

Cacciavite a stella

Kruiskopschroevendraaier

Tournevis à pointe cruciforme

Adjust

Ajustar

Einstellen

Ajustar

Regolare

Afstellen

Ajuster

Grounding screw installed at factory

10-32grounding screw

Earthing symbol IEC 60417 No. 5019affixed adjacent to grounding terminal

Grounding screw

A (1)[SYSAUxP2]

B (1)[Outlet cover]

C (1)[3/4" mud ring]

D (2) [Screw spacer]

E (4) 06-32 x 1/4"

F (1)06-32 x 1/2"

G (1) #06

(see note to left)

Page 5: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

Installation Instructions SYSAUxP2

5

Isolated Ground ReceptacleThis product incorporates an isolated ground receptacle,identified by the orange triangle on its face. This feature may beuseful to reduce common noise in the connected equipment. Itsintended use is to reduce electrical noise (electromagneticinterference) by purposely insulating the grounding circuit fromany metallic wiring system. The ground pin of the receptacle isconnected to the green/yellow wire and is isolated from themetal mounting yoke of the receptacle. The accessible metal ofthe product is connected to the green wire. If it is not desired touse this feature, connect the green/yellow and green wirestogether.

ReferencesApplication Guide for Isolated Ground Wiring Devices 2007,National Electrical Manufacturers Association (NEMA)IEEE Std 1100™-2005, “IEEE Recommended Practice forPowering and Grounding Electronic Equipment” (EmeraldBook), Section 8.5.3.2.IEEE Std 142™-2007, “IEEE Recommended Practice forGrounding of Industrial and Commercial Power Systems”(Green Book), Sections 5.5.1, 5.5.2NFPA-70, “National Electrical Code”, Article 250.146Connecting Receptacle Grounding Terminal to Box.

• (D) Isolated Ground Receptacles. Where installedfor the reduction of electrical noise (electromagneticinterference) on the grounding circuit, a receptaclein which the grounding terminal is purposefullyinsulated from the receptacle mounting means shallbe permitted. The receptacle grounding terminalshall be connected to an insulated equipmentgrounding conductor run with the circuit conductors.This equipment grounding conductor shall bepermitted to pass through one or more panel boardswithout a connection to the panel board groundingterminal bar as permitted in 408.40, Exception, soas to terminate within the same building or structuredirectly at an equipment grounding conductorterminal of the applicable derived system or service.Where installed in accordance with the provisions ofthis section, this equipment grounding conductorshall also be permitted to pass through boxes, wireways, or other enclosures without being connectedto such enclosures.

• Informational Note: Use of an isolated equipmentgrounding conductor does not relieve therequirement for grounding the raceway system andoutlet box.

C22.2 No. 1, “Canadian Electrical Code, Part 1”, Rule 10-906Bonding conductor connection to circuits and equipment.

• (6) A bonding jumper shall be installed to connectthe bonding conductor to the grounding terminal ofa receptacle and in such a manner thatdisconnection or removal of the receptacle will notinterfere with, or interrupt grounding continuity.

• (7) In the case of metallically enclosed systemswhere the grounding path is provided by the metalenclosure, a bonding jumper shall be installed tobond the grounding terminal of the receptacle to theenclosure.

• (8) Notwithstanding Sub-rules (6) and (7), thebonding jumper, in the case of receptacles havinggrounding terminals isolated from the mountingstrap required for special equipment, shall bepermitted to be extended directly back to thedistribution panel.

WARNING: IMPROPER INSTALLATION CAN RESULT INDEATH OR SERIOUS PERSONAL INJURY! This mountingsystem should be installed by qualified personnel.

IMPORTANT ! : In addition to the SYSAU installationinstructions accompanying the products, the followingsteps must also be taken when installing the SYSAUxP2.NOTE: The SYSAUxP2 must be connected to a 15 Amp

branch circuit.NOTE: In some installations, the electrical install may be

facilitated by loosening the wing nut and removing theentire outlet plate from the SYSAUxP2. (See Figure 1)

Figure 1IMPORTANT ! : There are two different methods ofSYSAUxP2 installation:

• If installing the SYSAUxP2 in the flush mode,proceed to Installing in Flush Mode section.

• If installing the SYSAUxP2 in the above-tile mode,proceed to Installing in Above-Tile Mode section.

Installing in Flush Mode1. Loosen, but do not remove, two Phillips head screws

holding outlet box to outer housing. (See Figure 2)

2. Rotate outlet box counter-clockwise until it is free to beremoved from housing. (See Figure 2)

3. Remove outlet box from housing. (See Figure 2)

Figure 2

(top view) Outlet plate

1 x 2

2

3

outlet box

(view from below)

Page 6: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

6

4. Wire the outlet box as required. Refer to Table 1 and Table2 for input and output specifications. (See Figure 3)

Table 1: Input Specifications

Table 2: Output Specifications

CAUTION: Isolated ground-mounting means NOTgrounded. Grounding wire connection required.

IMPORTANT ! : If a separate isolated green/yellowground wire is installed in the building wiring, attach itseparately to the green/yellow isolated ground wire onbox. If there is no separate green/yellow isolated groundwire, connect green ground wire to both green/yellowisolated ground wire and green box ground wire on box.NOTE: The grounding conductors serving this outlet are to be

connected to earth ground at the service equipment orother acceptable building earth ground such as thebuilding frame in the case of a high-rise steel-framestructure. Connections should be made with minimumAWG 14 copper wire intended for use on a 15 Ampcircuit. The conductors used to connect the outlet to theline or bus and ground shall not be any longer thannecessary and shall avoid unnecessary bends.

NOTE: An insulated grounding conductor that is identical insize and insulation material and thickness to thegrounded and ungrounded circuit supply conductors,except that it is green with or without one or moreyellow stripes, is to be installed as part of the circuit thatsupplies the outlet. Refer to Table 250-122 of theNational Electrical Code regarding the appropriate sizeof the grounding conductor.

NOTE: Pressure terminal or pressure splicing connectors andsoldering lugs used in the installation of the outlet shallbe identified as being suitable for the material of theconductors. Conductors of dissimilar metals shall notbe intermixed in a terminal or splicing connector wherephysical contact occurs between dissimilar conductorsunless the device is identified for the purpose andconditions of use.

Figure 3

5. Replace the outlet box in the housing. (See Figure 4)

6. Rotate outlet box clockwise until it is in proper position to besecured to the housing. (See Figure 4)

7. Tighten two Phillips screws to secure outlet box to housing.(See Figure 4)

Figure 4

Input

Input voltage, frequency 125 V AC, 60 Hz

Input connection type 4x14 AWG stranded, UL Style1015, CSA TEW

Input Wire colors Black - LineWhite - NeutralGreen - Box GroundGreen/Yellow - Isolated Ground

Input wire length (ft.) 1 (with a 3/4" stripped end)

Output

Output 15 A, 1875 W

Power consumption <0.5 watt

Fuses Thermal current interrupting circuitsare in MOVs

Quantity/Type Duplex NEMA 5-15R Isolated GroundReceptacle

Color/Markings Grey with protection symbol (Orangetriangle)

GREEN(box ground)

WHITE(neutral)

BLACK (line)

GREEN/YELLOW (isolated ground)

6

7 x 2

5

Housing

(View from underneath)

Page 7: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

Installation Instructions SYSAUxP2

7

8. Install outlet cover (B) over outlet box using one 6-32 x 1/2"Phillips flat head screw (F) and one #06 lock washer (G).(See Figure 5)

NOTE: Be sure to line up hole in outlet cover over light in outlet.

Figure 59. Proceed to Outlet Box Use section.

Installing in Above-Tile Mode1. Loosen, but do not remove, two Phillips head screws

holding outlet box to outer housing. (See Figure 6)

2. Rotate outlet box counter-clockwise until it is free to beremoved from housing. (See Figure 6)

3. Remove outlet box from housing. (See Figure 6)

Figure 64. Remove four Phillips screws from ring attached to outlet

box. (See Figure 7)

5. Remove and discard ring from outlet box. (See Figure 7)

Figure 7

6. Wire the outlet box as required. Refer to Table 1 and Table2 on previous page) for input and output specifications. (SeeFigure 3)

8

(B)

(View from underneath)

(F)

Line up holein outletcover overlight in outlet

(G)

1 x 2

2

3

outlet box

(view from below)

4 x 4

Ring

5

Above-Tile Installation Only

Page 8: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

8

7. Lower outlet box into the mud ring (C) and attach two screwspacers (D) inside the mud ring on either side of outlet boxusing four 06-32 x 1/4" Phillips pan head screws (E). (SeeFigure 8)

8. Lower housing from above SYSAU, install outlet boxassembly up into housing, and rotate clockwise into place.(See Figure 8) and (See Figure 9)

Figure 8

9. Tighten existing Phillips head screws (in outlet housing) tohold in place. (See Figure 9)

NOTE: Follow installation instructions (included with theSYSAU) to complete installation. Proceed with Step10 after the SYSAU is installed above the tile.

NOTE: Be sure to line up hole in outlet cover over light in outlet.

10. Install outlet cover (B) over outlet box using one 6-32 x 1/2"Phillips flat head screw (F) and one #06 lock washer (G).(See Figure 9)

Figure 9

Outlet Box UseNOTE: The "PROTECTED" light indicates that the surge

protection circuitry is active and operational. (SeeFigure 10)

Figure 10

11. Complete the installation following the SYSAU installationinstructions.

(E) x 4

(D)

(C)

Outlet box

HousingSYSAUxP2

8

7 Line up hole inoutlet cover overlight in outlet

10 (F)

(G)

(B)

10

(View fromunderneath)

9

8

"PROTECTED"indicator light

Page 9: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

Installation Instructions SYSAUxP2

9

Page 10: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

10

Page 11: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

Installation Instructions SYSAUxP2

11

Page 12: INSTALLATION INSTRUCTIONS ADDENDUM - …downloads.chiefmfg.com/manuals-i/SYSAUxP2-I.pdf · INSTALLATION INSTRUCTIONS ADDENDUM ... IEEE Std 1100™-2005, “IEEE Recommended Practice

SYSAUxP2 Installation Instructions

USA/International A 6436 City West Parkway, Eden Prairie, MN 55344P 800.582.6480 / 952.225.6000F 877.894.6918 / 952.894.6918

Europe A Franklinstraat 14, 6003 DK Weert, NetherlandsP +31 (0) 495 580 852F +31 (0) 495 580 845

Asia Pacific A Office No. 918 on 9/F, Shatin Galleria18-24 Shan Mei StreetFotan, Shatin, Hong Kong

P 852 2145 4099F 852 2145 4477

Chief, a products division ofMilestone AV Technologies

8800-002795 Rev012018 Milestone AV Technologies

www.milestone.com01/18