—I N S TA LL ATI O N I N S TR U C TI O N
Switch DisconnectorsOT2000-2500_-135
—
Swit
ch D
isco
nnec
tors
34O
T25
00
-135
rev
. A/
1SC
C30
110
1M0
201
2 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
— Table of contents
003 Installation
004 Label Terminal clamps, OZX_
005 TerminalshroudsOTS_
006 Barrierinstallation&Circuits
007 Connectionkit,OTKIT2500B11
008 OT2500E_-135Switchesratingsandsupporting distances
009 AuxiliarycontactsOA_
010 Auxiliarycontactswiring
011 ModuleforauxcontactsOEA28_
012 DirectmounthandleOTV_
013 InterlockingOTZT4
014 Dimensionaldrawings
015 Warningtable
3S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Installation
KA
00
065
1
TORX T404 Nm35 Ib.in
A
C
M85/16
B
00
1
Handle: OHB274J12
1.2 Nm11 Ib.in2
4 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Label
—Terminal clamps, OZX_
A04
027
OT2000-2500 OZXB3OZXB4OZXB5OZXB6OZXB7L
KA
00
071
2
LINE1
LOAD21
3
3
1
1
1
2
2
2
Attach the warning label YKLW8765 according the pictureDO NOT OPERATE UNDER LOAD
AT Ue > 690 V
DO NOT OPERATE UNDER LOADAT Ue > 690 V
DO NOT OPERATE UNDER LOAD
AT Ue > 690 V
DO NOT OPERATE UNDER LOADAT Ue > 690 V
5S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—TerminalshroudsOTS_
4
OTS2500 1SGT
OTS2500 1LGT
1
2
KA
00
066
M12 443-664 lb.in50...75 Nm
1
2
M
M
3
6 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Barrierinstallation&CircuitsBarrier 68912 installation
Circuit1OT2500E02-135
Circuit2OT2500E04-135, OT2500E22-135
Circuit3OT2500E04-135, OT2500E22-135
A0
40
28
Type for package of 6 barriers is OTB1600/6.
Barriers 68912 or shrouds must be used on all types at voltages ≥ 500 V.
1
167
170
100
127
2
+(-) -(+)
+(-) -(+)
+(-)1
-(+)1
+(-)2
-(+)2
+(-)1
-(+)1
+(-)2
-(+)2
+(-)1
-(+)1
+(-)2
-(+)2
+(-)1
-(+)1
+(-)2
-(+)2
+(-) -(+)
+(-) -(+)
+(-) -(+)
+(-) -(+)
7S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Connectionkit,OTKIT2500B11
Busbarconnection,Circuit3
M12 50...75 Nm443-664 lb.in
OTKIT2500B11 (includes 4 busbars) Busbar connection points,
Connection busbar recommended cross section 4x100x10 Cu
8 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—OT2500E_-135 Switches ratingsandsupportingdistances
Switchtypes
Num- ber of poles
Circuittype
DC-20Brating@1500V
AC-20Brating@1000V
Withbusbars Supportdistance180mm
lcw 0,3s
Max. Let-throughPeakCurrentwhenprotected withFusesor CircuitBreaker
Max. Let-throughEnergywhenprotected withFusesorCircuitBreaker
OT2500E02-135 OT2500E20-135 2 1 2500 A 2500 A 80 kA 176 kA 363 MA2s
OT2500E04-135 OT2500E40-135 4 2 2500 A 2500 A 80 kA 176 kA 363 MA2s
OT2500E22-135 4 2 2500 A 2500 A 80 kA 176 kA 363 MA2s
OT2500E04-135 OT2500E40-135 4 3 4000 A 4000 A 100 kA 220 kA 616 MA2s
OT2500E22-135 4 3 4000 A 4000 A 100 kA 220 kA 616 MA2s
WithBusbars,Supportdistance180mm
180 350
9S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—AuxiliarycontactsOA_
Main contact
Test contact (NO)
Test indication contact (NO)
Test contact (NC)
Test indication contact (NC)
or
KA
00
073
Remove
NO: OA1G10NC: OA3G01
Test contact
Test indication contact
MAX 2 MAX 2MAX 2
MAX 2 MAX 2MAX 2
TEST IND.TEST IND.
1 2
43
3 4
Early operation
test contact
2C2A
2B
0 1 0 Test 0
~10°
10 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Auxiliarycontactswiring
KA
00
072
13
4
3
2
11S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—ModuleforauxcontactsOEA28_
1
OEA281...8 pcsOA1G10 (NO)OA3G01 (NC)
KA
00
075
MainNO
NC
0.4 Nm3.5 lb.in
6
0.4 Nm3.5 lb.in
5
CLICK !
2
4
3
1
OEA281...8 pcsOA1G10 (NO)OA3G01 (NC)
KA
00
075
MainNO
NC
0.4 Nm3.5 lb.in
6
0.4 Nm3.5 lb.in
5
CLICK !
2
4
3
12 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—DirectmounthandleOTV_
OTV1000EK
A0
400
4
mmin
27410.79
903.54
1064.18
150.59
Note: Use protection against direct contact. For example:Ø5...10 mm
5
Tx201,2 Nm11 lb.in
21,2 Nm11 lb.in
1
4
3
13S W ITCH D ISCO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—InterlockingOTZT4
OTZT4_
A0
40
20
1 1C 1D
CLICK !
1B
Flat connection6,3-0,8 (DIN46244)
1A
The cable is not included in the delivery
2
2A
2B
5
1,2 Nm11 lb.in
5A
Handle: OHB274J125B
3
4 Nm 35 lb.inTorx 20
4B
4AOXP12x_
4
Locking
Ø8 mm 0.32 in
NOTE:min. 94 mm 3.7 in
14 S W ITCH D I S CO N N EC TO R S , OT 2 5 0 0 _ -1 3 5
—Dimensionaldrawings
02 04 22
A mmin
B mmin
A1 mmin
B1 mmin
C1 mmin
OT 2000/ 2500E_-135
1264.96
346,513.64
30612.05
33613.23
36214.25
1264.96
598,523.56
55821.97
58823.15
61424.17
1264.96
598,523.56
55821.97
58823.15
61424.17
25
13,5/0.53
25
A
B
116
42132
100
14
15
376
206
131,5
62,5
120.4722
0.87
0.55
5.18
8.12
14.81
2.46 0.59
0.980.98
3.94
5.21.65
4.57
60.24
401.57
853.35
376,514.83
*) N3 types
*)
*)
60.24*)
501.97
M0
013
7/ O
T20
00
_250
0E
01-
04
D
1676.57
1676.57
251...380 (OXP12x280)9.84...14.96
168/107,56.61/4.23
80.31
80.31
1787.01
min 20min 0.79
1275
1084.25
1054.13
mmin
*)
*)
2108.27
ABM
00
138/
OT
200
0_2
500
E0
1-0
4 D
M85/16
M85/16
200.79
54
80
70
27410.79
2.13
2.76
3.15
A1
232
27
55
C1
176
B1
223
42
1.06
9.14
8.79
1.65
2.17
6.93
2329.14
2238.79
1766.93
1536.02
A1
B11817.13
1686.61
C1