16
Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

Page 2: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

2

8"

1/2"

2"1/2"

FIGURE 2 FIGURE 3 FIGURE 4

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

FIGURE 1

This installation guide applies to the installation of Maibec ResistechTM panels, shingle strips and trims only. Carefully read this entire guide to understand all of the necessary steps and requirements for ensuring proper installation. DOWNLOAD THE LATEST VERSION ONLINE AT MAIBEC.COM. For assistance, please contact Maibec’s technical service toll-free at 1-800-363-1930, Monday to Friday from 8:30 a.m. to 4:30 p.m. (Eastern Time)

For the installation requirements for Maibec ResistechTM lap siding and soffits, please consult the installation guides for these products.

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Maibec ResistechTM engineered siding is for exterior use only.

This installation guide has been created according to Maibec’s requirements as well as to the requirements in the Louisiana-Pacific Corporation Installation Guide. Maibec’s requirements prevail over those of Louisiana-Pacific.

Drawings in this document are not to scale and are used solely to illustrate best practices.

All dimensions in this document are given in inches.

1. BASIC PRINCIPLES FOR INSTALLING SIDING Exterior siding is essential for protecting a home against water infiltration, but is not watertight. Water accumulation behind the siding can cause it to warp or swell, mould to form and even lead to rot inside the wall. This will affect the siding’s performance, durability and appearance.

1.1 MANAGING WATER

The following requirements must be respected to properly manage water: • Water must be able to drain away freely between the

siding and water-resistive barrier. • Install flashing over all openings, flat surfaces and wherever

moisture drainage is needed. Flashings must have a slope outward at an angle of at least 6% for adequate water drainage.

• Use weather-seal tape/membrane around windows, doors and all other openings to ensure a tight seal with the water-resistive barrier. This will protect the wall from water infiltration.

• No horizontal furring strips or surfaces at the bottom of walls to prevent water accumulation.

• Install gutters and kick out flashings on roofs.

ALLOW A MINIMUM CLEARANCE OF:

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

FURRING STRIP

FLASHING 6% SLOPE

VENTILATED SPACER

OPEN ON TOP

CONTINUOUS DRAINAGE OF INFILTRATED WATER

OPEN AT BOTTOM

8" from the ground - 2" from adjacent horizontal structures (e.g. decks, low walls, roof shingles) - 1/2" between siding and flashing

1/2" space between the siding and the flashing over all openings

Page 3: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

3

FIGURE 5

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

AIR GAP BETWEEN TWO

FURRING STRIPS

MOISTURE CAUSED BY HEAT FROM THE

SUN AND WATER VAPOUR EXPELLED

FROM THE INTERIOR CAN ESCAPE

AIR OUT 1/2" OPENING

AIR IN 1/2" OPENING

MINIMUM 6" FROM THE GROUND

1.2 VENTILATING THE WALL

• Continuous wall ventilation will allow heat and moisture to escape from between the siding and the insulating material. Using furring strips, create ventilated spaces (called air gaps or rainscreens) and leave a 1/2" minimum open space at the bottom and top of walls to allow air to enter and exit across the entire height and width of the wall.

• Wall ventilation is especially important when dark-coloured siding and/or foam insulation panels are used. Dark siding absorbs more heat and is more prone to thermal expansion. Foam insulation panels also tend to trap heat.

• Maibec ventilated strips* will allow proper water and heat management while preventing potential rodents and certain insects from getting in behind the siding. - Ventilated spacer: Used between furring strips at the top and bottom of panels; supports panels while ensuring adequate ventilation and drainage.

- Ventilated universal "L" strip: Top of windows, top and bottom of walls, and other types of installation. The addition of spacers is required depending on where the ventilated strip is used.

- Ventilated "J" strip: Bottom of windows and tops of walls.

- Ventilated universal band: Can be folded and cut on-site to meet any installation requirement.

*If non-Maibec ventilated strips are used, they must have a minimum 50% opening to ensure adequate ventilation of the wall.

1.3 PROTECTING THE INTEGRITY OF THE SIDING

To protect the integrity of the product, always follow the instructions for touching up and nailing the siding.

• Apply touch-up paint to any bare wood to seal it. This will keep water from seeping into the strands, ensuring the optimal performance of the siding and paint while preventing degradation. [SECTION 5]

• Correct nailing will result in a stable, long-lasting installation. [SECTION 4]

2. STORAGE• Keep the siding in a dry, unheated, well-ventilated

area away from the elements and at least 6" from the ground. Never let it come into direct contact with the ground.

• Cover any unused siding with its original packaging at all times, even during installation. If the original packaging is no longer in good condition, cover the siding with a waterproof tarp.

• Touch-up paint should always be kept at room temperature (15°C or 60°F).

FIGURE 6

Page 4: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

4

FIGURE 7

2 1/2"

3/8"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

INCORRECTCORRECT

3. BEFORE YOU BEGIN INSTALLATION

3.1 CHECK YOUR ORDER

• Make sure the product(s) delivered matches your order (colour, model, dimensions, quantity, nails, accessories, etc.).

• Sealant.• Have touch-up paint on hand.

• Inspect each piece prior to installing it. Never install a product that appears to be or that you think may be defective. Installed defective products are not covered by the warranty. Contact Maibec at 1 800 363-1930.

NOTE: Maibec sells sealant for stock program products but not for custom colour products. Be sure to have a sufficient amount of ASTM C920-approved, minimum Class 25 sealant on hand for sealing butt joints, gaps between siding and trim and all other gaps as needed. Maibec does not recommend customizable sealant.

For a list of ASTM-compliant sealant, go to maibec.com.

3.2 CONSULT THE BUILDING CODES

Make sure you are familiar with the specific requirements of all applicable federal and provincial building codes and municipal by-laws for your region with respect to installing siding, water-resistive barrier, sealant, etc. For the water-resistive barrier and the sealant, follow the manufacturers’ instructions.

For more information, see the National Model Construction Codes on the Government of Canada’s website at nationalcodes.nrcc.gc.ca

4. INSTALLATION SYSTEMMaibec ResistechTM siding is installed with Maibec hot dipped galvanized steel ring shank corrosion resistant nails with textured head as described below. These nails must be ordered at the same time as your siding.

DO NOT USE STAPLES.

4.1 NAIL SPECIFICATIONS

The nails specified below ensure the required minimum real penetration of 1 1/2" into solid wood. These nails are available only from Maibec.

8d (2 1/2") hot dipped galvanized steel ring shank Maibec coil nails with:

• A minimum .095" shank

• A minimum .219" head diameter

• Rings starting at 3/8" from the head

If Maibec ResistechTM siding is installed in Coastal regions*, unstained stainless steel grade 316 ring shank nails must be used for installing siding and trims. These nails must have the same features (shank, head, length and ring pattern) as that of galvanized steel ring shank nails described above. Failure to comply with this requirement will void the warranties.

* APPLICABLE COASTAL REGIONS INCLUDE THOSE LOCATED LESS THAN 600 M (2,000 FT) FROM THE COASTLINE IN THE ATLANTIC PROVINCES (NEW BRUNSWICK, PRINCE EDWARD ISLAND, NOVA SCOTIA, NEWFOUNDLAND AND LABRADOR), IN SAINT-PIERRE-ET-MIQUELON, AND IN THE U.S. EAST COAST STATES.

For information on installing Maibec ResistechTM products in high wind speed areas, refer to ICC-ES Report ESR-1301 or APA PR-N124.

Page 5: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

5

FIGURE 8

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

5. TOUCH-UPS• To ensure the optimal performance of the siding and paint, all cut panels, batten, shingle strip edges and trims must

be resealed to prevent water from seeping into the strands and causing degradation over time. • Apply touch-up paint to all cut or planed surfaces and to all exposed substrate, even if it will not be visible after the

siding is installed. Always touch up boards BEFORE installing them.

RESEAL ALL CUT BOARDS DO NOT SPILLOVER OR OVERBRUSH

APPLY PRECISELY

• Apply touch-up paint to all visible nail heads (and some invisible nail heads - FIGURE 8). Most of these nails can be found on panels, battens, shingle strip edges installed above doors, above and under windows, along the starter course, on corner trims, as well as around doors, windows and other openings on the wall.

• Use a polyester, nylon or any synthetic applicator with firm bristles approved for water-based coatings.• Touch-up paint is included with your order. If you need more, you can purchase a Maibec-approved paint

from your retailer. See the list of Maibec-approved paints in the Painting Guide at maibec.com.

NEVER APPLY TOUCH-UP PAINT OVER NON-DAMAGED OR UNCUT FACTORY COATED MATERIAL. IMPROPER APPLICATION OF THE TOUCH-UP PAINT CAN RESULT IN DIFFERENCES IN COLOUR THAT WILL NOT NECESSARILY APPEAR IMMEDIATELY, BUT WHICH MAY BECOME MORE NOTICEABLE OVER TIME AFTER PROLONGED EXPOSURE TO ULTRAVIOLET RAYS.

For more information, consult the touch-up guide that accompanies the touch-up paint or go to maibec.com.

4.2 NAILING

• Ensure nails have a minimum real penetration of 1 1/2" in a solid substrate (wood, plywood or OSB). Nails must also penetrate into the structure. This penetration is obtained by using two nails to secure the board at the required locations.

• Do not overdrive nails. Nail head should seat firmly to face of siding but not be overdriven to distort the siding surface.

• All exposed face nails must be properly sealed in a manner that prevents moisture intrusion and water buildup.

SNUG

FLUSH

VISIBLE FIBER

COUNTERSUNK 1/16" - 1/8"

COUNTERSUNK MORE THAN 1/8"

OK

OK

PAINT

APPLY SEALANT

APPLY SEALANT. RE-NAIL

PAINT

PAINT

PAINT

APPLY SEALANT AND PAINT.

APPLY SEALANT AND PAINT. RE-NAIL

CONDITION CORRECTION : INVISIBLE NAILS VISIBLE NAILS

FIGURE 9 FIGURE 10

Page 6: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

6

FIGURE 11

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

FOUNDATION

6. SEALANTUse a ASTM C920-approved, minimum Class 25 sealant for sealing butt joints, gaps between siding and trim, and all other gaps as needed.

7. GENERAL STRUCTURE OF THE WALLSiding and trims must be installed over:

• A standard maximum 16" stud built wall.• Nailing base consisting of furring strips and

OSB (oriented strand board) or plywood, or foam insulation panels combined with OSB or plywood.

• For siding panels only: Ventilated spacer between furring strips at the top and bottom of panels.

• Approved water-resistive barrier (Tyvek®, Typar, etc.).

• Flashing installed over all openings, flat surfaces and wherever moisture drainage is needed.

• Weather-seal tape/membrane around windows, doors and all other openings to ensure a tight seal with the water-resistive barrier. This will protect the wall from water infiltration.

• Ventilated barriers preventing rodents and certain insect from infiltrating behind the siding.

Check the structural integrity of the wall prior to installation. It must be solid and straight, with an adequate nailing base to hold the siding securely in place. Maibec cannot be held responsible for any damage to the siding caused by the movement of a structure that has not been built on a frost-protected foundation.

Verify that the wall’s watertightness is ensured by a properly installed water-resistive barrier and appropriate flashing.

If you are using insulating concrete forms (ICF), please contact Maibec for technical assistance.

8. MAIBEC RESISTECHTM PANEL AND SHINGLE STRIPS INSTALLATION MAIBEC RESISTECHTM PANEL CAN ONLY BE INSTALLED VERTICALLY.

MAIBEC RESISTECHTM SHINGLE STRIPS CAN ONLY BE INSTALLED HORIZONTALLY.

8.1 MANDATORY VERTICAL FURRING STRIPS

Vertical furring strips create a ventilated space (called an air gap or rainscreen) between the siding and the water-resistive barrier. This space allows any water that may infiltrate behind the siding due to driving rain, wind or morning dew to escape rather than accumulating behind the siding. It also allows water vapour from inside the building released by the water-resistive barrier to escape without damaging the wall.

MANDATORY FURRING STRIP SPECIFICATIONS

• 1" x 3" furring strips (1" x 4" or 2" x 3" is acceptable) must be used. This requirement applies especially when foam insulation panels less than 1” thick are used.

• Furring strips must be kiln-dried with a moisture content below 19%. • They must be new, straight and undamaged. If the siding is being installed as part of a renovation project, replace all

existing furring strips with new compliant strips.

VENTILATED "L" STRIP

FURRING STRIP

WATER-RESISTIVE BARRIER

VENTILATED SPACER (PANELS ONLY)

Page 7: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

7

FIGURE 12

FIGURE 13

FIGURE 14

1"

1/2"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

8.1 Mandatory vertical furring strips (cont’d)

INSTALLING FURRING STRIPS

• Install furring strips vertically and secure them firmly to the structure using one staggered nail or angle screw every 6" maximum. Nails/screws must have a maximum penetration of 1 1/2" in the structure. [FIGURE 12]

• Furring strips should have a maximum spacing of 16" on centre. Maibec prohibits a spacing of 24" between furring strips.

• Furring strips must extend beyond the concrete foundation line by 1" minimum to ensure the overlap of the siding and the foundation.

IMPORTANT - If foam insulation panels exceeding 1" in thickness are used or if the siding is installed in a high wind speed area, 1" x 4" or 2" x 3" vertical furring strips must be installed over the insulation to hold it in place. It is the installer’s responsibility to ensure the furring strips are firmly nailed/screwed to the structure and spaced a maximum of 16" on centre with a minimum nail/screw penetration depth of 1 1/2". Nails/screws cannot be spaced further apart than the width of the siding. Maibec and Louisiana-Pacific will assume no responsibility for any damage or condition arising from the use of foam insulation panels.

STRUCTURE

6" MAXIMUM BETWEEN

NAILS/ SCREWS

FURRING STRIP

FOUNDATION

FURRING STRIPS MUST

EXTEND BEYOND THE

FOUNDATION

FORBIDDEN

16" BETWEN FURRING STRIPS

8.2 PREPARING THE BOTTOM OF WALLS AND THE STARTER COURSE

BOTTOM OF WALLS

Install siding at least 8" from the ground to avoid exposing it to splashing rain and soil moisture. [FIGURE 14]

Siding should never come into direct contact with the ground.

Cut the surface of the siding such that the rotation of the blade cuts downward on the prefinished surface.

NEVER INSTALL FURRING STRIPS DIAGONALLY, WHICH WILL IMPEDE VENTILATION OF THE WALL AND PREVENT WATER FROM DRAINING FREELY. NEVER INSTALL FURRING STRIPS HORIZONTALLY AT THE BOTTOM OF WALLS OR AROUND DOORS AND WINDOWS. [FIGURE 13]

1" MINIMUM

VENTILATED "L" STRIP8"

FROM THE GROUND

Page 8: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

8

16"

FIGURE 15

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

8.2 Preparing the bottom of walls and the starter course (cont’d)

STARTER COURSE WITH MAIBEC VENTILATED STRIPS

Use one of the following ventilated strips* for the starter course:

- Ventilated universal "L" strip: The ventilated universal "L" strip ensures proper ventilation and drainage behind panels and shingle strips. A shim must be installed along the bottom of the ventilated strip to create the correct angle for the shingle strip. The shim consists of 1 1/2" high by 3/8" thick piece of siding and must run the entire perimeter of the building. Touch-up stain should be applied to the entire shim. [FIGURE 15]

- Ventilated universal band: Use the universal band if furring strips exceed 3/4" in thickness or if insulation panels are used. The ventilated band will cover the furring or insulation panels, preventing potential rodents and certain insects from getting behind the siding. The addition of a spacer is required for shingle strip.

*If non-Maibec ventilated strips are used, they must have a minimum 50% opening to ensure adequate ventilation of the wall.

Install the ventilated strip with a precision (laser) level or other type of level directly over the furring strips. The bottom of the furring strips should reach to the bottom of the ventilated strip. Secure with 2 nails horizontally every 16".

- Ventilated spacer: Used between furring strips at the top and bottom of panels; supports panels while ensuring adequate ventilation and drainage.

8.3 NAIL PLACEMENT ON SIDING

MAIBEC RESISTECH™ PANELS (VISIBLE NAIL SIDING)

• Install panels over furring strips with a maximum spacing of 16" on center.

• The edges of panels with overlap grooves must fall directly in the centre of the furring strip.

• Space nails 6" on center along the vertical edges of the panel. Nails spaced 6" on center along the bottom groove will be covered by the overlap flange. Nails spaced 6" on center on the overflap flange should be 1" from the edge of the panel. Use 2 nails at the top and bottom of panels between furring strips centered at 5 3/8". Nail panel on intermediate furring strips at 12" on center vertically. [FIGURE 26]

• Nails will be exposed on the overlap flange, along the horizontal edges at the top and bottom of panels and below window sills. Apply touch-up paint to all visible nails.

• It is recommended to use a fine-tooth carbide blade to ensure as smooth a cut as possible and to maintain the lifespan of the blade. Cut the surface of the siding so that the rotation of the blade cuts downward on the prefinished surface.

VENTILATED SPACER

VENTILATED "L" STRIP

Page 9: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

9

FIGURE 17

FIGURE 16

FIGURE 18

1/2"

1"

3/8"

3/8"

1/8" 1/8"

1"

3/4"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

8.3 Nail placement on siding (cont’d)

BATTENS

• To install battens, use 2 nails at each end, with additional nails spaced a maximum of 12" apart vertically on alternating edges along the length of the batten. [FIGURE 17]

BATTENPANEL

FURRING STRIP

VENTILATED SPACER PANEL WITH 1" X 2" BATTENS

TIP Space battens

symmetrically on the wall. Battens should cover the nails at panel joints. [FIGURE 16]

1 3/4" OVERLAP

10" EXPOSURE

SPACER

VENTILATED "L" STRIP

SHINGLE STRIPS (VISIBLE NAILS)

Start by nailing a 1 1/2" high by 3/8" thick shim to the ventilated strip. [FIGURE 18]

Staggered shingle strip: • When installing the staggered strip over another material,

the starter strip should be installed with the right side facing down. Continue installation according to the instructions in the next point.

• Working from left to right, install the first row of siding so that the random edge does not extend more than 1/2" below the shim.

• Cut the left edge so that the siding butts snugly against the corner board, with a gap of 3/16”. Make sure the other edge of the strip falls against a stud so that it can be nailed in place.

Straight shingle strip: • Working from right to left, install the first row of

siding so that the straight edge does not extend more than 1/2" below the shim.

• Cut the right edge so that the siding butts snugly against the corner board, with a gap of 3/16". Make sure the other edge of the strip falls against a stud so that it can be nailed in place.

Use the "alignment groove" in the edge of the shingle strip as an automatic guide for overlapping each row of shingles. At least 1 3/4" of the lower part of the groove should be covered. Nail 3/4" from the bottom edge to penetrate both layers of siding. All siding joints should fall on studs. Double nail at the edges of shingle strips. [FIGURES 19, 20 AND 21]

8" FROM THE GROUND

Page 10: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

10

FIGURE 25

3/8"

3/8"

FIGURE 19 FIGURE 20 FIGURE 21

Exposition de la barrière

perméable à l'air et

perméable à l'air

32 mm

32 mm

résistante à l'eau

mesure à partir du bas

centre la bride

montant

chevauchement

revêtement

Les extrémités des bardeaux doivent aboutir sur des montants.

Vue détaillée du clouage

Figure 2

Figure 3

Figure 5

Revêtement primaire et barrière résistante à l'eau

Exposition de la barrière

perméable à l'air et

perméable à l'air

32 mm

32 mm

résistante à l'eau

mesure à partir du bas

centre la bride

montant

chevauchement

revêtement

Les extrémités des bardeaux doivent aboutir sur des montants.

Vue détaillée du clouage

Figure 2

Figure 3

Figure 5

Revêtement primaire et barrière résistante à l'eau

1 1/4"

16" 16"

3/8"

Exposition de la barrière

perméable à l'air et

perméable à l'air

32 mm

32 mm

résistante à l'eau

mesure à partir du bas

centre la bride

montant

chevauchement

revêtement

Les extrémités des bardeaux doivent aboutir sur des montants.

Vue détaillée du clouage

Figure 2

Figure 3

Figure 5

Revêtement primaire et barrière résistante à l'eau

3/4"

3/8"

Exposition de la barrière

perméable à l'air et

perméable à l'air

32 mm

32 mm

résistante à l'eau

mesure à partir du bas

centre la bride

montant

chevauchement

revêtement

Les extrémités des bardeaux doivent aboutir sur des montants.

Vue détaillée du clouage

Figure 2

Figure 3

Figure 5

Revêtement primaire et barrière résistante à l'eau

3/4"

3/8"

1 1/4"

1"

FIGURE 22 FIGURE 23 FIGURE 24

3/8"

1/8" 3/8"

3/8" 3/8" 1/8" 1/8"

1" 1"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

PANEL-TO-TRIM

APPLY SEALANT

SPACING BETWEEN 3/16" TO 1/4"

SEALANT

8.3 Nail placement on siding (cont’d)

ALIGNMENT NOTCH

STAGGERED SHINGLE STRIP STRAIGHT SHINGLE STRIP

PANEL-TO-PANEL

SURFACE NAILING GROOVED PANEL

SURFACE NAILING NON-GROOVED PANEL

NAILING ALONG LOWER STRIP

FURRING STRIPFURRING STRIP

VENTILATED SPACER

VENTILATED SPACER

USE SEALANT ONLY WHERE NEEDED. IMPROPER USE OF SEALANT MAY PREVENT WATER DRAINAGE.

8.4 END JOINTS

PANEL-TO-PANEL AND PANEL-TO-TRIM

• Joints must occur over a furring strip and the bottom panel must be centred.• Nail at least 3/8" from the top and 1" from the edge of the panel. [FIGURE 22] • Where the siding butts against trim, door frames, masonry, etc., leave a 3/16" to 1/4" gap and apply sealant.

[FIGURE 25]

PANEL, SHINGLE STRIPS AND TRIM CAN VARY BY UP TO 1/16" (+/–) IN THICKNESS. AS A RESULT, SOME BOARDS MAY NOT ALIGN PERFECTLY. THIS IS NORMAL AND TO BE EXPECTED.

Page 11: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

11

FIGURE 26

FIGURE 27 FIGURE 28

3/8" 3/8"

1"1 5/8"1/2"

3/8"

6"

5 3/8"

12"

3/8"3/8"3/8"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

PANEL

FLASHING FLASHING

8.5 SUBSEQUENT COURSES

PANEL

• Do not force siding during installation.

• Joints must fall in the center of furring strips. [FIGURE 26]

• Verify course alignment with a level at every panel and adjust as needed. A maximum gap of 1/16" between panels is considered normal.

• If you are installing one panel above another, leave a 3/8" gap between flashing and the upper panel. [FIGURE 27]

• Make sure there is a ventilated spacer running along the top and bottom of each panel to properly support it and to provide adequate ventilation and drainage.

BATTENS

• If using battens, make sure they are not longer than the height of one storey. [FIGURE 28]

SHINGLE STRIPS

Depending on whether you’re following the random or straight strips installation method, begin installing the subsequent rows in the same way, but cut each length so that joints are staggered. For best results, shorten the first piece of the second row by 16" and the first piece of the third row by 32". Repeat this sequence every three rows. [FIGURE 19]

9. TRIMS AND CORNERSTrims should be thick enough so the siding does not extend beyond the face of the trim.

9.1 CUTTING TRIMS

• For the cleanest cut and longer blade life, a fine-tooth carbide tipped blade is recommended. Cut the surface of the trim such that the rotation of the blade cuts downward on the prefinished surface.

VENTILATED SPACER AT THE BOTTOM AND TOP OF THE PANELS

FLASHING

VENTILATED SPACER

VENTILATED "L" STRIP

PANEL PANEL

BATTEN

Page 12: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

12

FIGURE 29

FIGURE 31 FIGURE 32

3/8"

FIGURE 30

FIGURE 33

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

9.3 CORNERS

Maibec recommends finishing corners with Maibec ResistechTM trims or Maibec metal corners.

SEALANT

SEALANT

TRIM UNDER 7" WIDE AND BATTEN

1" x 2" AND 1" x 3"

9.1 Cutting trims(cont’d)

• Do not rip and/or rout the trim, as it will leave the edges unprotected. All cut trims must be resealed to prevent water from seeping into the strands. Apply touch-up paint to all cut surfaces and/or to all exposed substrate, even if it will not be visible after the siding is installed. Always touch up boards BEFORE installing them.

• Do not miter trim ends or edges. 45 degree diagonal cuts of trim ends around door and window opening are not permitted, as well as joining.

9.2 NAILING TRIMS AND END JOINTS

• For trims under 7" wide, fasten with 2 nails at both ends, with additional fasteners spaced a maximum of 12" along alternating edges the length of the trim. [FIGURE 30]

• Nails must have a penetration of 1 1/8" in solid wood.• Apply nails to meet specifications in Section 4.• Nail quantity:

- For trims under 7" wide use a minimum of 2 nails per width. - For trims 7" to 12" wide use a minimum of 3 nails per width.

• A 3/16" to 1/4" gap is required at trim joints and where edges of trim meet siding material, windows, doors or other finished openings to allow for proper sealing.

TOUCH-UP PAINT

NO 45 DEGREE DIAGONAL

CUTS

NEVER NAIL INTO EDGES

DO NOT MITER EDGES

DO NOT MITER CUT THE

CORNER JOINT

7" TO 12" TRIM

MAXIMUM 12" BETWEEN NAILS

MAXIMUM 6" BETWEEN

NAILS

2 NAILS AT TOP AND BOTTOM OF TRIM 3 NAILS AT

TOP AND BOTTOM OF TRIM

SEALED END JOINT 3/16" TO 1/4"

GAP AND SEAL

FURRING STRIP

2 1/2" NAIL

3/16" TO 1/4" GAP

3/16" TO 1/4" GAPTRIM MUST EXTEND BEYOND FACE OF SIDING

TRIM MUST EXTEND BEYOND FACE

OF SIDING

Page 13: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

13

FIGURE 34

FIGURE 35

2"

2"

2"

1/2"

1/2"

1/2"

1/2"

1/2" 1/2"

1/2"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

10.3 OTHER JUNCTIONS

Always install flashing and a ventilated strip to ensure ventilation when there is on the same wall:

SIDING AND OTHER MATERIAL FIGURE 36

2 1/2 OR MORE STORIES OF PANEL FIGURE 37

BOTTOM

OTHER MATERIAL

FLASHING

TOP

SEALANT

PANELPANEL BATTEN

FURRING STRIP

FLASHING

FLASHING

TRIM

2 1/2 OR MORE STORIES OF PANEL AND BATTENFIGURE 38

VENTILATED SPACER

10. JUNCTIONS

10.1 SIDING-DECK JUNCTION

• Siding must never come into direct contact with a balcony or deck. At all times, the installation should allow rainwater to drain freely and prevent pooling water from ice dams from penetrating behind the siding. Leave a 2" space between adjacent horizontal structures and a 1/2" space between the siding and the flashing. [FIGURE 34]

• Install the ventilated starter strip directly to the furring at the bottom of the wall.

10.2 DORMER-ROOF JUNCTIONS

• Leave a 2" space between the siding and the surface of the roof to allow water to drain freely. [FIGURE 35]

• Install the ventilated "L" strip or the universal band at the bottom of the dormer.

DECK

FLASHING

2" BETWEEN STRUCTURES

1/2" DRAINAGE AND AIRFLOW

VENTILATED "L" STRIP AND

VENTILATED SPACER

VENTILATED "L" STRIP

VENTILATED "L" STRIP AND

VENTILATED SPACER

VENTILATED "L" STRIP AND

VENTILATED SPACER

VENTILATED "L" STRIP AND VENTILATED

SPACER

VENTILATED "L" STRIP AND VENTILATED SPACER

VENTILATED "L" STRIP AND VENTILATED SPACER

ROOF CLADDING

FURRING STRIP

Page 14: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

14

1/2"

1/4"

6%

1/2"

1/2"

1/4"

6%1/2"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

FLASHING

FLASHING

11. WINDOW AND DOOR FINISHING DETAILS• The siding’s installation must allow for continuous

ventilation and adequate drainage above and below all openings. Maibec offers a full range of ventilated trims to ensure this.

• If you plan to install Maibec ResistechTM trims, you must properly set the window or door depth according to the thickness of the furring strips, the siding being installed and the trim.

• The trim must not extend too far past the window or door frame in areas where water can accumulate (header and sill). If the siding butts to the frame, the frame must be as deep as the thickness of the wall plus the thickness of the siding.

11.1 ABOVE WINDOWS

Flashings over openings must:

• Have a slope outward at an angle of at least 6%. • Minimum 1/2" spacing between flashing and the siding

to allow for adequate drainage and air flow.

• Cover the building element below it vertically by at least 1/2".

• Projection of at least 1/4" beyond the outer face of the building element below it.

A shim must be added to the row of shingle strips installed at the tops of windows. See section 8.3 for more details. The ventilated spacer is required between furring strips at the bottom of the panel. [FIGURE 11]

WITHOUT MAIBEC RESISTECHTM TRIMFIGURE 40

WITH MAIBEC RESISTECHTM TRIMFIGURE 39

FURRING STRIP

FLASHING

TRIM

FURRING STRIP

VENTILATED "L" STRIP

VENTILATED "L" STRIP

FURRING STRIP

FLASHING

VENTILATED SPACER BETWEEN TWO

FURRING STRIPS

VENTILATED SPACER BETWEEN TWO

FURRING STRIPS

Page 15: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

15

FIGURE 41 FIGURE 42

3/4"

1/2"

1/2"

3/4"

1/2"

3/4"

1/2"

FIGURE 44FIGURE 43

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

Installation Guide Maibec ResistechTM Panel, Shingle Strips and Trims

11.2 BELOW WINDOWS

All flat horizontal surfaces (such as window sills) are prone to water or snow accumulation. To avoid such accumulation, one of the following options is mandatory: • Flashing with a minimum 6% slope • Sealant• Ventilated spacer (panel only)

To minimize movements in the boards, ventilation at the bottom of windows is required when the window has a width of more than 4 ft and is located more than 4 ft from the first course.

WITH MAIBEC RESISTECHTM TRIM

SEALANT

SEALANT

SEALANT SEALANT

TRIM

FLASHING

INCORRECT

WITHOUT MAIBEC RESISTECHTM TRIM

SEALANT

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

TIP For a neat finish, make

a cut in the board of siding and insert underneath the

ventilated "J" strip.

12. TOP OF WALLS FINISHING DETAILS Several ventilated strips can be used to allow air to circulate and for heat to escape at the top of the wall.

VENTILATED "J" STRIP

TOUCH UP NAIL HEAD

TOUCH UP NAIL HEAD

VENTILATED "J" STRIP

WITHOUT MAIBEC RESISTECHTM TRIM - VENTILATED "J" STRIPFIGURE 45

VENTILATED "J" STRIP

TOUCH UP NAIL HEAD

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

WITHOUT MAIBEC RESISTECHTM TRIM - VENTILATED "L" STRIPFIGURE 46

VENTILATED "L" STRIP

*WHEN ROOF OVERHANG EXCEEDS 2"

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

Page 16: Installation Guide - Maibec...• Install gutters and kick out flashings on roofs. ALLOW A MINIMUM CLEARANCE OF: Installation Guide Maibec Resistech TM Panel, Shingle Strips and Trims

16

1/2"

FIGURE 49

1/2"

3/4"

FIGURE 50

1/2"

3/4"

COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

1 800 363-1930 maibec.com

202 – 1984, 5e Rue, Lévis QC G6W 5M6 Canada

® REGISTERED TRADE-MARK PROPERTY OF MAIBEC INC. © COPYRIGHT - MAIBEC INC PRINTED IN CANADA AUGUST 2020 A1818463.5A 76-00195-N

IMPORTANT: COMPLIANCE WITH MAIBEC’S INSTALLATION, STORAGE AND MAINTENANCE REQUIREMENTS, AND WITH ALL APPLICABLE BUILDING CODES IS MANDATORY. PROBLEMS CAUSED BY FAILURE TO COMPLY WITH THESE REQUIREMENTS AND CODES MAY NOT BE COVERED BY THE APPLICABLE WARRANTIES.

13. FINISHING GABLES AND BOTTOM SIDES OF DORMERS The ventilated "J" strip allows for proper ventilation of the wall.

Extra pieces of furring strips must be added at the top of the wall. These pieces must be 3’ long to allow siding to be properly nailed in place without blocking airflow. Do not add furring diagonally as this will block airflow.

Refer to section 8.5 and 10.3 for siding junctions.

PANEL

SHINGLE STRIPS

TRANSITION FLASHING

14. MAINTENANCE As with all exterior products, siding is prone to organic or inorganic substances accumulating on its surface over time. This is a natural phenomena and is to be expected. To ensure the performance and longevity of your siding, check its appearance on a regular basis.

See the maintenance guide at maibec.com for more details.

SIDING

VENTILATED BAND

ROOF FLASHING

TOUCH UP NAIL HEAD

12. Top of walls finishing details (cont’d)

FURRING STRIP

FLAT ROOF – VENTILATED BAND FIGURE 48

WITH MAIBEC RESISTECHTM TRIM - VENTILATED "L" STRIP OR VENTILATED BAND*FIGURE 47

VENTILATED BAND

2" TRIM

*WHEN ROOF OVERHANG EXCEEDS 2”

SEALANT

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

VENTILATED SPACER BETWEEN TWO FURRING STRIPS

FURRING STRIP

VENTLATED "J" STRIP INSTALLED ON AN ANGLE

FURRING STRIP

TOUCH UP NAIL HEAD

VENTLATED "J" STRIP

VENTILATED SPACER