Page 1: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

Installation Guide

ZKAccess.com

F18 Standalone Fingerprint Reader

&

ZKAccess | Classic softwear 3.5

Page 2: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

2

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

What’s in the Box

Diode

ZKAccess Software

F18

4 Large, Small Screws & Anchors

Screwdriver

ZKAccess Security Management Software

Installation Template Back PlateRubber Gasket

AC Power Adapter

Network Cable Adaptor

Power Cable AdaptorNetwork Cable Cables

Page 3: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

3

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

CONTENT

What’s in the Box .................................................................... 2

Optional accessories ............................................................ 4

Safety Precautions.................................................................. 5

Product PIN Diagram ........................................................... 6

Product Dimension ............................................................... 8

Cables and Connectors ..................................................... 9

Mounting the reader on the Wall ............................ 10

Power Connection ............................................................. 11

Ethernet Connection ........................................................ 12

RS485 Connection .............................................................. 14PC Connection ......................................................................... 14FR1200 Connection ................................................................ 16System Settings ........................................................................ 16

Lock Relay Connection ................................................... 18Normall Open Lock ................................................................. 18Normall Close Lock ................................................................. 19

Wiegand Output Connection .................................... 20Standalone Installation .......................................................... 21Third Party Controller .............................................................. 22

How Does F18 work .......................................................... 23How to Place a Finger on Scanner ......................... 24

Troubleshooting .................................................................. 26

Electrical Specifications ................................................. 27

Specifications ........................................................................ 28

ZKAccess | CLASSIC 3.5

Software Installation and Setupstarts at page 30

Page 4: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

4

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Optional accessories

Wiegand Card Reader

FR1200 FP Reader

Prox Card

K1-1 Exit Button

Page 5: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

5

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Safety PrecautionsThe following precautions are to keep user’s safe and prevent any damage. Please read carefully before installation

Do not install the device in a place subject to direct sun light, humidity, dust or soot

Do not place a magnet near the product. Magnetic objects such as magnet, CRT, TV, monitor or speaker may damage the device.

Do not place the device next to heating equipment

Be careful not to let liquid like water, drinks or chemicals leak inside the device.

Do not let children touch the device without supervision

Do not drop or damage the device

Do not disassemble, repair or alter the device.

Do not use the device for any other purpose than specified.

Clean the device often to remove dust on it. In cleaning, do not splash water on the device but wipe it out with smooth cloth or towel.

Contact your supplier in case of a problem.

Page 6: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

6

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

RESE

T

Product PIN Diagram

Figure 1

2.4 inch TFT LCD

USB Memory slot

Reset Switch

Speaker

Star-shaped screw hole for fixing reader to the back plate

Keypad & RF Card Area

Door Bell & LED Indicator Area

ZK Optical Sensor

Page 7: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

7

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

7 pin Cable connectors

4 pin Cable connectors – Ethernet (TCP/IP)

8 pin Cable connectors

2 pin Cable connectors

10 pin Cable connectors

Tamper alarm button

• Beep, LED

•Wiegand In

• Power Out

•Wiegand Out

• RS232

• RS485

• Power In

• Bell

•Door Sensor

• Button

• Lock

• Alarm

Page 8: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

RESE

T

8

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

3.15in (80mm)

2.8in (72mm)

1.65in (42mm)

7.2in (183mm)

6.75in (173mm)

Product Dimension

Page 9: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

9

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Cables and Connectors

1

10

PIN DESCRIPTION WIRE1 Bell- Purble2 Bell+ Brown3 Sensor White4 GND Black5 Button Gray6 NO Blue7 COM Red8 NC Yellow9 Alarm+ Orange

10 Alarm- Green

• Alarm

• Lock

• Button

•Door Sensor

•Door Bell

1

8

PIN DESCRIPTION WIRE1 WD0 Green2 WD1 White3 GND Black4 232 RX Gray5 232 TX Purple6 GND Black7 485A Blue8 485B Yellow

•Wiegand Output

• RS232

• RS485

1

7

PIN DESCRIPTION WIRE1 12V Red2 GND Black3 INWD1 White4 INWD0 Green5 RLED Blue6 GLED Gray7 BEEP Purple

•Wiegand Output

• LED

• Power Out

• Beep

RJ 4

5

12345678

1

4

PIN DESCRIPTION WIRE1 RJ45-1 Yellow2 RJ45-2 Green3 RJ45-3 Red4 RJ45-6 Black

• TCP/IP

12

PIN DESCRIPTION WIRE1 12V DC Red2 GND Black • Power In

Page 10: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

10

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Mounting the reader on the WallFix back plate to the wall using wall mounting screws

We recommend drilling the mounting plate screws into solid wood (i.e. stud/beam). If a stud/beam cannot be found, then use the supplied drywall plastic mollies (anchors).

RESE

T

RESE

T

Use star-shaped screw to mount itInserting Reader to backplate

1

2

Page 11: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In OutputRS

485

RS2

32

W

iega

nd O

ut

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

Without UPS

With UPS (Optional)

12V DC Adaptor

GND

12V DC

12

Recommended power supply

•12V ± 10%, at least 500mA.

•Comply with standard IEC/EN 60950-1.

• To share the power with other devices, use a power supply with higher current ratings

11

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Power Connection

12V DC Adaptor

GND

12V DC

12

Page 12: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

12

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In OutputRS

485

RS2

32

W

iega

nd O

ut

Bell Button Lock Alarm PowerDoorSensor

Ethernet Connection

RJ 45

1 2 3 4 5 6 7 8

14

Network Cable Adaptor

Ethernet Cable

PIN DESCRIPTION WIRE1 RJ45-1 Yellow2 RJ45-2 Green3 RJ45-3 Red4 RJ45-6 Black

LAN Connection

Page 13: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

13

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In OutputRS

485

RS2

32

W

iega

nd O

ut

Bell Button Lock Alarm PowerDoorSensor

RJ 45

1 2 3 4 5 6 7 8

14

Network Cable Adaptor

Ethernet Cable

PIN DESCRIPTION WIRE1 RJ45-1 Yellow2 RJ45-2 Green3 RJ45-3 Red4 RJ45-6 Black

Direct Connection

Page 14: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

14

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

RS485 Connection

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

PC Connection

1

8

PIN DESCRIPTION WIRE1 WD0 Green2 WD1 White3 GND Black4 232 RX Gray5 232 TX Purple6 GND Black7 485A Blue8 485B Yellow

Important Notes:

1. RS485 communication wires should be a shielded and twisted pair cable.

2. RS485 communication wires should be connected in a bus cascade instead of a star form, to achieve a better shielding effect by reducing signal reflec-tion during communications.

3. Adjust the communication speed as needed. The signal quality vary depend-ing on wiring conditions, and it maybe necessary to lower the baudrates.

4. The GND Signal may be omitted if and only if the GND potential difference is less than ±5V

Do not use

Page 15: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

15

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

RS485

#1 F18 #2 F18 #63 F18

RS485 --RS485 +GND

Incorrect RS 485 connections

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

NO

COM

NC

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

D

AUXOUT4

SEN

GN

D

NO

COM

NC

LOCK1

SEN

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3

SEN

GN

D

NO

COM

NC

LOCK4 LOCK POWER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

NO

COM

NC

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

D

AUXOUT4

SEN

GN

D

NO

COM

NC

LOCK1SE

N

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3

SEN

GN

D

NO

COM

NC

LOCK4 LOCK POWER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1IN G

ND

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

NO

COM

NC

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

D

AUXOUT4SE

N

GN

D

NO

COM

NC

LOCK1

SEN

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3

SEN

GN

D

NO

COM

NC

LOCK4 LOCK POWER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READERN

OCO

MN

C

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

D

AUXOUT4

SEN

GN

D

NO

COM

NC

LOCK1

SEN

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3SE

N

GN

D

NO

COM

NC

LOCK4 LOCK POWERIN G

ND

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

NO

COM

NC

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

D

AUXOUT4

SEN

GN

D

NO

COM

NC

LOCK1

SEN

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3

SEN

GN

D

NO

COM

NC

LOCK4 LOCK POWER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

+

+

+

BUTTON BUTTONREADER 1 READER 2BUTTON BUTTONREADER 1 READER 2TX RX

TX

ACT

LIN

K

RX

POW

ERRU

NCA

RD

AUX 1

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12V

GN

D

485-

485+

AUX 2 AUX 3 AUX 4 EXT EXT

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

NO

COM

NC

485+

485

--G

ND

PC AUXOUT1

NO

COM

NC

AUXOUT2

NO

COM

NC

AUXOUT3

NO

COM

NC

V+ V- 12V

GN

DAUXOUT4

SEN

GN

D

NO

COM

NC

LOCK1

SEN

GN

D

NO

COM

NC

LOCK2

SEN

GN

D

NO

COM

NC

LOCK3

SEN

GN

D

NO

COM

NC

LOCK4 LOCK POWER

IN GN

D

BEEP

GLE

D

WD

1

WD

0

GN

D

+12V

BUTTON READER

1 2 3 4 5 6 7 8

ON

RS485

#1 F18

#1F18

#2 F18

#2 F18

#63 F18

#63 F18

RS485 --RS485 +GND

RS485 --RS485 +GND

RS485

x

x

Page 16: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

16

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

RS485 Connection

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

FR1200 Connection

1

8

FR1200

F18

Do not use

PIN DESCRIPTION WIRE1 WD0 Green2 WD1 White3 GND Black4 232 RX Gray5 232 TX Purple6 GND Black7 485A Blue8 485B Yellow

1 7

PIN DESCRIPTION WIRE1 12V Red2 GND Black3 INWD1 White4 INWD0 Green5 RLED Blue6 GLED Gray7 BEEP Purple

Page 17: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

17

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

System Settings

DIP Settings

1 2 3 4 5 6

ON

1 2 3 4 5 6

ON

Distance: More than 200 meters

1. There are six DIP switches on the back of FR1200, switches 1-4 is for RS485 address, switch 5 is reserved, switch 6 is for reducing noise on long RS485 cable.

2. If FR1200 is powered from F18 terminal ,the length of wire should be less than 100 meters or 330 ft.

3. If the cable length is more than 200 meters or 600 ft., the number 6 switch should be ON as below

Select > Access Setting Select > User Management

Select > Anti-Passback setting Change > 485 Reader Fun to (Y)

Page 18: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

18

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

PIN DESCRIPTION WIRE1 Bell- Purple2 Bell+ Brown3 Sensor White4 GND Black5 Button Gray6 NO Blue7 COM Red8 NC Yellow9 Alarm+ Orange

10 Alarm- Green

Lock Relay Connection

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

Normally Open Lock

1

10

FR107Diode

+-

GND NOSensor

Do not use

1 7

12V DCCOM

Page 19: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

19

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

PIN DESCRIPTION WIRE1 Bell- Purple2 Bell+ Brown3 Sensor White4 GND Black5 Button Gray6 NO Blue7 COM Red8 NC Yellow9 Alarm+ Orange

10 Alarm- Green

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

Normally Closed Lock

1

10

FR107Diode

+-

GND NCSensor

Do not use

1 7

12V DCCOM

Page 20: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

20

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Wiegand Output Connection

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

SN 0000000000000

Fingerprint Access Control

SBTS Registered No H021

Power Supply DC 12V == 3A

Operating Environment Temperature: 0ºC-45ºC

ISO9001 : 2008 FC R0HS 6 9 3 7 0 2 2 6

RJ4

5-1

RJ4

5-2

RJ4

5-3

RJ4

5-6

BELL

-BE

LL+

SEN

GN

DBU

TN

01C

OM

1N

C1

N02

CO

M2

+12

VG

ND

+12

VG

ND

IWD

1IW

D0

RLE

DG

LED

BEEP

WD0WD1GNDRXDTXDGND485+485-

Ethernet Power out Wiegand In Output

RS48

5

R

S232

Wie

gand

Out

Bell Button Lock Alarm PowerDoorSensor

Do not use

1

8

PIN DESCRIPTION WIRE1 WD0 Green2 WD1 White3 GND Black4 232 RX Gray5 232 TX Purple6 GND Black7 485A Blue8 485B Yellow

EXT

RS

48

5E

XT

RS

48

5P

CR

S4

85

PC

RS

48

5C

AR

DC

AR

DR

UN

RU

NP

OW

ER

PO

WE

R

LA

NL

AN

485+

485-

SGND

NO

COM

NC

NO

COM

NC

NO

COM

NC

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

V+

V-

+12V

GND

485+

485-

SGND

NO

COM

NC

NO

COM

NC

NO

COM

NC

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

V+

V-

+12V

GND

IN

GND

IN

GND

IN

GND

IN

GND

+12V

GND

485-

485+

IN

GND

IN

GND

IN

GND

IN

GND

+12V

GND

485-

485+

AU

X 1 A

UX 2

AU

X 3

AU

X4

EXT

ST

AT

E B

UT

TO

N 1 R

EA

DE

R 1 B

UT

TO

N 2 R

EA

DE

R 2 B

UT

TO

N 3 R

EA

DE

R 3 B

UT

TO

N 4 R

EA

DE

R 4

AU

X 1 A

UX 2

AU

X 3

AU

X4

EXT

ST

AT

E B

UT

TO

N 1 R

EA

DE

R 1 B

UT

TO

N 2 R

EA

DE

R 2 B

UT

TO

N 3 R

EA

DE

R 3 B

UT

TO

N 4 R

EA

DE

R 4

Be

st Se

curity S

olu

tion

for th

e W

orld

B

est S

ecu

rity So

lutio

n fo

r the

Wo

rld

PWR

RUN

ACT

GRD

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

PWR

RUN

ACT

GRD

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

SW

ITC

HS

WIT

CH

PC

PC

AU

XO

UT

1A

UXO

UT

1A

UXO

UT

2A

UXO

UT

2A

UXO

UT

3A

UXO

UT

3A

UXO

UT

4A

UXO

UT

4L

OC

K1

LO

CK

1L

OC

K2

LO

CK

2L

OC

K3

LO

CK

3L

OC

K4

LO

CK

4L

OC

KL

OC

KP

OW

ER

PO

WE

R

Ad

va

nc

ed A

cc

es

s C

ontro

l

EXT

RS

48

5E

XT

RS

48

5P

CR

S4

85

PC

RS

48

5C

AR

DC

AR

DR

UN

RU

NP

OW

ER

PO

WE

R

LA

NL

AN

485+

485-

SGND

NO

COM

NC

NO

COM

NC

NO

COM

NC

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

V+

V-

+12V

GND

485+

485-

SGND

NO

COM

NC

NO

COM

NC

NO

COM

NC

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

SEN

GND

NO

COM

NC

V+

V-

+12V

GND

IN

GND

IN

GND

IN

GND

IN

GND

+12V

GND

485-

485+

IN

GND

IN

GND

IN

GND

IN

GND

+12V

GND

485-

485+

AU

X 1 A

UX 2

AU

X 3

AU

X4

EXT

ST

AT

E B

UT

TO

N 1 R

EA

DE

R 1 B

UT

TO

N 2 R

EA

DE

R 2 B

UT

TO

N 3 R

EA

DE

R 3 B

UT

TO

N 4 R

EA

DE

R 4

AU

X 1 A

UX 2

AU

X 3

AU

X4

EXT

ST

AT

E B

UT

TO

N 1 R

EA

DE

R 1 B

UT

TO

N 2 R

EA

DE

R 2 B

UT

TO

N 3 R

EA

DE

R 3 B

UT

TO

N 4 R

EA

DE

R 4

Be

st Se

curity S

olu

tion

for th

e W

orld

B

est S

ecu

rity So

lutio

n fo

r the

Wo

rld

PWR

RUN

ACT

GRD

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

PWR

RUN

ACT

GRD

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

IN

GND

BEEP

GLED

WD1

WD0

GND

+12V

SW

ITC

HS

WIT

CH

PC

PC

AU

XO

UT

1A

UXO

UT

1A

UXO

UT

2A

UXO

UT

2A

UXO

UT

3A

UXO

UT

3A

UXO

UT

4A

UXO

UT

4L

OC

K1

LO

CK

1L

OC

K2

LO

CK

2L

OC

K3

LO

CK

3L

OC

K4

LO

CK

4L

OC

KL

OC

KP

OW

ER

PO

WE

R

Ad

va

nc

ed A

cc

es

s C

ontro

l

GND WD1 WD0

Page 21: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

21

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Standalone Installation

ALARM

EXIT

No Touch

RS232/485 Converter

Sensor

Lock

Exit Button

RS485 Ethernet

Page 22: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

22

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Third Party Controller

Lock

Outside OutsideInsideInside

Lock

Ethernet

EXTRS485

EXTRS485

PCRS485

PCRS485 CARDCARD RUNRUN POWERPOWER

LANLAN

48

5+

48

5-

SG

ND

NO

CO

M

NC

NO

CO

M

NC

NO

CO

M

NC

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

V+

V-

+12

V

GN

D

48

5+

48

5-

SG

ND

NO

CO

M

NC

NO

CO

M

NC

NO

CO

M

NC

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

SE

N

GN

D

NO

CO

M

NC

V+

V-

+12

V

GN

D

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12

V

GN

D

48

5-

48

5+

IN GN

D

IN GN

D

IN GN

D

IN GN

D

+12

V

GN

D

48

5-

48

5+

AUX 1 AUX 2 AUX 3 AUX4 EXT STATE BUTTON 1 READER 1 BUTTON 2 READER 2 BUTTON 3 READER 3 BUTTON 4 READER 4AUX 1 AUX 2 AUX 3 AUX4 EXT STATE BUTTON 1 READER 1 BUTTON 2 READER 2 BUTTON 3 READER 3 BUTTON 4 READER 4

Best Security Solution for the World Best Security Solution for the World

PW

R

RU

N

AC

T

GR

D

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

PW

R

RU

N

AC

T

GR

D

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

IN GN

D

BE

EP

GL

ED

WD

1

WD

0

GN

D

+12

V

SWITCHSWITCH PCPC AUXOUT1AUXOUT1 AUXOUT2AUXOUT2 AUXOUT3AUXOUT3 AUXOUT4AUXOUT4 LOCK1LOCK1 LOCK2LOCK2 LOCK3LOCK3 LOCK4LOCK4 LOCKLOCK POWERPOWER

A d vanced Acces s Con trol

Wiegand Output Connection

Wiegand Output

Wiegand Output

Wiegand Output

Wiegand Output

Page 23: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

23

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

How Does F18 Work

Fingerprint must be registered firstby any finger print reader

Fingerprint Database

Identification

Verification failed

Verification

Finger Registration

Granted

Please try again !

Thank You

Door Opens

Event Log Stored

Page 24: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

24

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

How to Place a Finger on Scanner

ZKTeco’s fingerprint readers will give optimal results for fingerprint matching if the following recommendations and suggestions are followed.

Select a finger to enroll

• It is recommended to use an index finger or a middle finger.

• Thumb, ring or little finger are relatively difficult to place in the correct position

How to place a finger on a sensor

• Place a finger such that it completely covers the sensor area with maximum contact.

• Place core of the fingerprint at the center of the sensor. The core of a fingerprint is a center where the spiral of ridges is dense. (Usually core of fingerprint is the opposite side of the lower part of a nail.)

• Place a finger such that the bottom end of a nail is located at the center of a sensor.

Page 25: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

25

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Tips for different fingerprint conditions

• ZKTeco’s fingerprint products are designed to verify fingerprints with highest security irrespective of the conditions of the skin of the finger. However, in case a fingerprint is not read on the sensor, please refer to the followings tips.

ū If a finger is stained with sweat or water, scan after wiping moisture off.

ū If a finger is covered with dust or impurities, scan after wiping them off.

ū If a finger is way too dry, please blow some warm air from your mouth on the finger tip.

Tips for fingerprint enrollment

• In fingerprint recognition, enrollment process is very important. When enrolling a fingerprint, please try to place the finger correctly with utmost care.

• In case of low acceptance ratio, the following actions are recommended.

ū Delete the enrolled fingerprint and re-enroll the finger.

ū Try another finger if a finger is not easy to enroll due to scar or cuts.

• In case of an enrolled fingerprint cannot be used due to injury or if the hand is full, it is recommended to enroll more than two fingers per user.

Upright

Sideways

Skewed

Partial

DO NOT place the finger in the following positions

If a finger is placed as shown on the left, only a small area of a finger is captured. So it is recommended to place a finger as shown on page 24.

Page 26: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

26

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Troubleshooting

1. Fingerprint can not be read or it takes too long. › Check whether a finger or fingerprint sensor is stained with sweat, water, or dust › Retry after wiping off finger and fingerprint sensor with dry paper tissue or a mildly wet cloth.

› If a fingerprint is way too dry, blow on the finger and retry.

2. Fingerprint is verified but authorization keeps failing. › Check whether the user is restricted by group or time zone. › Check with administrator whether the enrolled fingerprint has been deleted from the device for some reason.

3. Authorized but door does not open. › Check whether the lock open duration is set to appropriate time, which opens the lock. › Check whether anti-passback mode is in use. In anti-passback mode, only the person who has entered through that door can exit.

4. Why device display “system broken“ and the alarm is ringing. › Check whether the device and back plate are securely connected to each other. If not, a tamper switch is activated which triggers the alarm and keeps it ringing.

5. How to set F18 used as fingerprint reader on inBio access controller. › Reeference the Wiegand Output Connection on page 20. › Enroll personnel’s PIN in inBio panel as a card

Page 27: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

27

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Electrical Specifications

Minim

um

Typical

Maxim

um

Notes

WORKING POWER SUPPLY

Voltage (V) 9.6 12 14.4 Use regulated DC power adaptor only

Current (A) 2

ELECTRONIC LOCK RELAY OUTPUT

Switching voltage (V) 12V Use regulated DC power adaptor only

Switching Current (A) 2

SWITCH AUX. INPUT

VIH (V) TBD

VIL (V) TBD

Pull- up resistance (Ω) 4.7kThe input ports are pulled up with 4.7k resistors

WIEGAND INPUT

Voltage (V) 10.8 12 13.5

Current (mA) 500

TTL/WIEGAND OUTPUT

VOH (V) 5

VOL (V) 0.8

Pull- up resistance (Ω) 4.7KThe outputs ports are open drain type, pulled up with 4.7k resistors internally

ZK ELECTRONIC LOCK

Voltage (V) 10.8 12 13.2

Current (mA) 500

Page 28: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

28

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Specifications

Fingerprint Capacity 3,000

Transaction capacity 100,000

Hardware Platform ZEM720

CPU ZK 6001, 400Mhz

Memory 64MB Flash, 32MB SDRAM

Fingerprint Sensor ZK optical sensor

Display 2.8” TFT LCD color screen

LED Indicator Red, Green

Communication Ethernet (10/100M), RS485, USB-HOST

Wiegand Signal Wiegand Input and Wiegand Output

Identification Speed ≤2 sec

FAR ≤0.0001%

FRR ≤1%

Operating Temperature 32º to 113º F ( 0º to 45º C)

Operating Humidity 20%-80%

Language English, Spanish, Portuguese, French…

Power Supply 12V DC, 3A

Access control interfaces Electric lock, alarm, exit button, wired door bell

Dimension W: 80x H: 183x D: 42mm ( W: 3 1/8” x H: 7 1/4” x D: 1 5/8“)

Certified

Page 29: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

29

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Page 30: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

30

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

ContentsDownloading ......................................................................... 31

Installation ............................................................................... 32

Adding an Area ..................................................................... 33

Adding a Device................................................................... 34To add a standalone device: ................................................. 34To add an Access Control Panel:.......................................... 35

Creating a Time Zone ....................................................... 36Creating an Access Level ............................................... 37

Creating Departments/ Enrolling Personnel .. 38

Importing Personnel Data from Device ............. 40

Exporting Personnel Data to Device ..................... 41

Door Settings ......................................................................... 42

Real Time Monitoring ....................................................... 43

Exporting Reports ............................................................... 44

Passage Mode ........................................................................ 45

First-Card Normal Open ................................................. 46

ZKAccess CLASSIC 3.5Installation Guide

Page 31: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

31

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

1. Go to zkaccess.com

2. Hover over Downloads then click Software Downloads in the dropdown menu.

3. Scroll to the bottom of the page and click ZKACCESS CLASSIC 3.5 to download

4. Extract Files to a Setup Folder

5. Open the setup folder and run setup.exe to install

If you do not have software to extract compressed files, Scroll up on the same page to find Winrar 32 or Winrar 64 to download

Downloading

2

5

3

Page 32: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

32

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Installation

1. Click Next until asked to choose a path for storing backup files

2. Click Browse and Make New Folder , now click OK

3. Click Next and then Install

1

2

2 2

3

Page 33: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

33

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

1. Click Area

2. Click Add

Before adding devices, it is required to add an area to manage devices. The system, by default, has set an area named Area Name and Area ID [1] .

3. Input the Area Name,

4. Area Code (Unique ID number up to 8 digit)

5. Choose a Parent Area from the dropdown menu

6. Click OK

Adding an Area

1

2

3

4

5

6

Page 34: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

34

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

1. Click Device

2. Click Add

To add a standalone device:

Adding a Device

21

3. Input a Device Name

4. For Access Control Panel Type, select [Standalone SDK Machine]

5. Choose an Area

6. Input the device’s IP Address

7. Click OK

3

6

7

4

5

Page 35: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

35

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

2. Click Search , and it will prompt [Please wait……];

3. Click the device you wish to add. Click Add Device

1. Click Search Access Control Panels , to show the Search interface, supports Ethernet and RS485 search.

223

3

To add an Access Control Panel:

1

4

5

4

4

4. Input a device name, type, and area.

5. Click OK

Page 36: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

36

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Creating a Time Zone

1. Click Access levels > Add to enter Add access levels edit interface;

Time Zones are used to set when readers will be active, when doors will be open, and when specified users will have access to specified doors.

1

2. Input a Time Zone Name

3. Click and drag in each day’s frame to set up to three intervals per day or holiday

23

Page 37: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

37

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Creating an Access Level

1. Click Access levels > Add

1

1

Access levels means in a specific time period, which door or door combination can be opened through verification

2. Set the access level name, time zone, doors, and personnel that will have access.

3. Click OK to complete setting and quit

2

2

2

Page 38: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

38

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Creating Departments/ Enrolling Personnel

1. Click Department > Add to create Departments.

1. Click Personnel > Add to show personnel profile edit interface

Before managing Personnel it is required to describe the company’s departmental organization.

Creating Departmets

Enrolling Personnel

1

1

1

1

2

2

2

2

2. Input department name and de-partment number. Choose parent department. Then click OK

Page 39: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

39

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

2. Enter a Personnel Number. It cannot exceed 9 digits.

3. Select a department from the pull-down menu

4. (Optional) Enter a card number manually or using a card issuer.

5. (Optional) Enter a password for readers with keypad

6. (Optional) Click USB Sensor to enroll fingerprints.

2 34

58

6

7. Select a finger and press on the sensor three times. When you see “Succeed in fingerprint registration” Click OK

7

8. (Optional) Register employee as Administrator through [Terminal Management]

9. Click the Alternative Access Levels tab choose the user’s Access Level. Click OK

9

9

Page 40: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

40

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Importing Personnel Data from Device

1. Click Device . Choose a device to import personnel from. Get Personnel Data From Device to import from device

1

2. Choose Personnel, Fingerprints, or Face Templates to download, click Get

2

Page 41: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

41

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Exporting Personnel Data to Device

1

1. To export personnel data to another device, go to Access levels > Edit

2. Add the personnel and device to an access level. Click OK

3. Go to Device , choose a device to export the personnel to, and click Sync All Data To Device

4. Click Synchronize .

2

3

4

Page 42: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

42

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Door Settings

2

3

3

3

3

33

1

1. Click Door Setting , select the door to be modified, click Edit

2. Set the verification mode desired for the door.

3. (Optional) Modify the Door’s name, active time zone, passage mode, sensor type, lock open duration, and duress settings.

Page 43: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

43

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Real Time MonitoringMonitor the statuses and real-time events of doors under the access control panels in the system in real-time.

1. Click Real-Time Monitoring to view live events

1

2. Right click on the door icon to remote open/close.

3. Choose door open time or Enable Intraday Passage Mode

4. Choose close door or Disable Intraday Passage Mode

2

Page 44: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

44

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Exporting Reports

1. Click Reports to access transaction logs

2. Set filters to examine desired transactions, click Search

3. Click Export to export reports in XLS, PDF, or TXT file format

3

2

1

Page 45: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

45

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Passage Mode The Passage Mode feature will keep a door unlocked during a specified time zone. It will automatically unlock at the beginning of the time zone and will lock auto-matically at the end of the specified time zone.

1

2

3

1. Create a new Time Zone with the hours you want the door to be unlocked.

2. In Door Settings, Click Edit to change door settings.

3. Click the dropdown menu titled “Door Passage Mode Time Zone” and select your new time zone

Page 46: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

46

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

First-Card Normal OpenThe First Card Normal Open feature will keep a door unlocked during a specified time zone when triggered by specified personnel. After a reader has been used by a specified personnel that day, the door will unlock automaticcally at the begin-ning of the time zone and lock again at the end of the specified time zone.

2

4

7 7

6

3

8

1. Create a new time zone with the hours you want the door to be unlocked.

2. Select the First-Card Normal Open Menu

3. Click Setting

4. Click Add Door

5. Choose the door you want to set to normal open and the time frame it will be unlocked. Click OK

6. Select the door and click Add Personnel

7. Select Personnel and use the arrow buttons to move them to the Selected personnel panel.

8. Click OK

Design and Specifications subject to change without notice. © 2015 ZKTeco and its subsidiaries.

Page 47: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

47

F18 & ZKAccess CLASSIC 3.5 software INSTALLATION GUIDE

Page 48: Installation Guide - zktecousa.com · Fingerprint Access Control SBTS Registered No H021 Power Supply DC 12V == 3A Operating Environment Temperature: 0ºC-45ºC ISO9001 : 2008 FC

Vers

ion:

Mar

ch 2

015