2
Updated 6.11.2020 © Copyright 2020 Franklin Electric www.franklin-controls.com | 800.962.3787 | 310 Sequoia Parkway, Canby, Oregon 97013 indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations. indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. This is the safety alert symbol. Read and follow instructions carefully to avoid a dangerous situation. This symbol alerts the user to the presence of “dangerous voltage” inside the product that might cause harm or electrical shock. DANGER WARNING CAUTION Safety Instructions Equipment starts automatically. Lockout/tagout before servicing. As with all electrical products, read manual thoroughly. Only qualified, expert personnel should perform maintenance and installation. Contact the nearest authorized service facility for examination, repair, or adjustment. Do not disassemble or repair unit unless described in this manual; death or injury to electrical shock or fire hazard may result. Specifications and manual data subject to change. Consult factory for additional information. DANGER CAUTION 1Ø AC Input 50/60 Hz L1 L2/N T1 T2 M Voltage Input Auto Run Fault Output Status Output Dry Input Auto Run Normally Open Input 12-120VAC/DC Input Main Power Wiring Wire main power input and output to the appropriate 12AWG wire leads utilizing properly sized wire nuts. Use only copper conductors rated at least 60°C. Maintain proper clearances and verify that no possibility of an electrical short exists between the power conductors or enclosure. Ensure that wires are not under stress and all insulation is intact. Low Voltage Wiring Automation system control wiring should be run in a separate conduit. The control terminals accept 26~14AWG wire torqued to 3.5 in-lb. Installation FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN DEATH OR SERIOUS INJURY Mounting Mount the starter on a minimum 14 cu-in single gang junction box. To access mounting holes, slide upper and lower covers to the open position. (See Figure 1) Using provided mounting screws (6-32 x 7/8”), attach starter housing to junction box (once appropriate wiring has been completed). materials. Contact arcing can induce explosion or fire. g n i t n u o m e f a S . y l n o s n o i t a c o l e t a i r p o r p p a ) 1 A M E N ( 1 e p y T L U n i r e t r a t s l l a t s n I requires a dry, protected environment. • The BAS-1P is rated for maximum ambient temperature of 40°C . e r u s o l c n e r e t n e o t n o i t a l l a t s n i m o r f s i r b e d r o s g n i v a h s l a t e m y n a w o l l a t o n o D WARNING Figure 1 HAZARDOUS VOLTAGE . t n e m p i u q e g n i c i v r e s r o g n i l l a t s n i e r o f e b r e w o p l l a t u o k c o l d n a t c e n n o c s i D e c i v r e s o t r o i r p s e c r u o s r e w o p e l p i t l u m t u o g n i k c o l e r i u q e r y a m t n e m p i u q e s i h T d n a l a c i r t c e l e l a n o i t a n & l a c o l e l b a c i l p p a l l a h t i w e c n a d r o c c a n i e r i w d n a l l a t s n I construction codes Installation & Operation Guide LIT-12013012 Thank you for purchasing the Franklin Electric Single Phase Building Automation Starter! Please read this manual thoroughly to ensure safe installation and proper operation. Precautions To prevent injury and property damage, follow these instructions. Failure to adhere to installation/operation procedures and all applicable codes may result in hazards as indicated by warning codes outlined below:

Installation & Operation Guide Mounting

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Installation & Operation Guide Mounting

Updated 6.11.2020 © Copyright 2020 Franklin Electricwww.franklin-controls.com | 800.962.3787 | 310 Sequoia Parkway, Canby, Oregon 97013

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. This signal word is to be limited to the most extreme situations.

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.

This is the safety alert symbol. Read and follow instructions carefully to avoid a dangerous situation.

This symbol alerts the user to the presence of “dangerous voltage” inside the product that might cause harm or electrical shock.

DANGER

WARNING

CAUTION

Safety Instructions

Equipment starts automatically. Lockout/tagout before servicing.

As with all electrical products, read manual thoroughly. Only qualified, expert personnel should perform maintenance and installation. Contact the nearest authorized service facility for examination, repair, or adjustment. Do not disassemble or repair unit unless described in this manual; death or injury to electrical shock or fire hazard may result. Specifications and manual data subject to change. Consult factory for additional information.

DANGER

CAUTION

1Ø AC Input 50/60 Hz

L1 L2/N

T1 T2

M

Voltage Input Auto Run

Fault Output

Status Output

Dry Input Auto Run

Normally Open Input

12-120VAC/DC Input

Main Power WiringWire main power input and output to the appropriate 12AWG wire leads utilizing properly sized wire nuts. Use only copper conductors rated at least 60°C. Maintain proper clearances and verify that no possibility of an electrical short exists between the power conductors or enclosure. Ensure that wires are not under stress and all insulation is intact.

Low Voltage WiringAutomation system control wiring should be run in a separate conduit. The control terminals accept 26~14AWG wire torqued to 3.5 in-lb.

InstallationFAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN DEATH OR SERIOUS INJURY

MountingMount the starter on a minimum 14 cu-in single gang junction box. To access mounting holes, slide upper and lower covers to the open position. (See Figure 1)

Using provided mounting screws (6-32 x 7/8”), attach starter housing to junction box (once appropriate wiring has been completed).

• materials. Contact arcing can induce explosion or fire.

gnitnuom efaS .ylno snoitacol etairporppa )1 AMEN( 1 epyT LU ni retrats llatsnI •requires a dry, protected environment.

• The BAS-1P is rated for maximum ambient temperature of 40°C.erusolcne retne ot noitallatsni morf sirbed ro sgnivahs latem yna wolla ton oD •

WARNING

Figure 1

HAZARDOUS VOLTAGE

.tnempiuqe gnicivres ro gnillatsni erofeb rewop lla tuo kcol dna tcennocsiD •ecivres ot roirp secruos rewop elpitlum tuo gnikcol eriuqer yam tnempiuqe sihT • dna lacirtcele lanoitan & lacol elbacilppa lla htiw ecnadrocca ni eriw dna llatsnI •

construction codes

Installation & Operation GuideLIT-12013012

Thank you for purchasing the Franklin Electric Single Phase Building Automation Starter! Please read this manual thoroughly to ensure safe installation and proper operation.

PrecautionsTo prevent injury and property damage, follow these instructions. Failure to adhere to installation/operation procedures and all applicable codes may result in hazards as indicated by warning codes outlined below:

Page 2: Installation & Operation Guide Mounting

QSTART-BAS1P-V3 © Copyright 2020 Franklin Electricwww.franklin-controls.com | 800.962.3787 | 310 Sequoia Parkway, Canby, Oregon 97013

3.2884.984

2.808

1.4272.147

HAND

RESE

TAU

TO

All dimensions in inches

Dimensions

OperationOverload AdjustmentConfirm nameplate Full Load Amperage (FLA) to ensure proper overload protection. Using a flathead screwdriver, turn the adjustment dial to the desired amperage setting. The starter is not rated to protect loads exceeding 16 amps @120VAC, and 8.8A @230VAC.

LED Status Indicators

POWER (PWR)Illuminates when voltage is applied to the input terminals and main power switch is in the ON (I) position.

RUNUnder a RUN condition, the RUN LED will remain illuminated if the BAS-1P senses current providing status. The LED will flash when the unit does not sense current.

FAULT (FLT) - Overload TripThe BAS-1P indicates a fault condition by flashing the red FAULT LED which will remain constant in the event of a fault trip. The LED will also flash if a RESET attempt is made during the 180 second overload cool down period.

Operation Modes

RESETTo reset the starter to normal operation following a Fault condition, slide the 3-position switch to RESET and hold for a minimum of 5 seconds (after 180 second cool down period has elapsed). Once starter has been reset, return switch to the desired mode.

MANUAL (HAND MODE) In Manual or HAND mode, the BAS-1P will function as a manual motor controller. Select the ON (I) position on the main power switch to engage motor.

AUTOMATIC (AUTO MODE) When utilizing the starter in the AUTO mode, a signal sent via the terminal inputs (located on rear of unit) determine motor operation (ON or OFF).

Lockout OptionsTo lockout, slide the lower cover upward to reveal concealed locking grasp. Insert a standard padlock to prevent unauthorized access or tampering. If multiple padlocks are required, an optional padlocking attachment can be utilized (not included). See Figure 2B.

Figure 2A Figure 2B

HAND

RESE

TAU

TO

PWR

RUN

FLT

Product Ratings

123456

Overload AdjustmentOperation Mode SelectorMain Power Switch*PWR Power Status LEDRUN Run Status LEDFLT Fault / Overload LED

UL 508 HorsepowerShort Circuit Protection Interrupt

Current Max Current Overload Reset115VAC 230VAC

BAS-1P 1HP

Suitable for use on a circuit capable of delivering not more than 1kA RMS Symmetrical Amperes, 230 Volts maximum when protected by Class RK5 fuses (30 Amp max) or inverse time circuit breaker (40 Amp max)

Ik ≤ 1kA RMS Symmetrical

16A @ 120VACI2t Class 10 Manual

1

2

3

4

5

6

*This device meets NFPA-70 (NEC) motor disconnect requirements per paragraph 430.109 (C)(2) Stationary Motors of 2HP or Less.

8.8A @230VAC