2 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Hydraulic System Design Calculations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Model Code Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Model Code Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Specifications and Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Control Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Performance – Industrial
PVM018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
PVM020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PVM045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
PVM050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PVM057 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
PVM063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
PVM074 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
PVM081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
PVM098 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
PVM106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
PVM131 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
PVM141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Dimensions
PVM018/020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
PVM045/050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
PVM057/063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
PVM074/081 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
PVM098/106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
PVM131/141 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Mounting Flange Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Shaft Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Input Shaft Selection Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Port Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Operating Requirements and Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Installation and Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
M Series Variable Displacement Piston Pumps
3 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Introduction
Eaton M Series pumps are open circuit, axial pis-ton designs. A variety of control options allows the pumps to perform most efficiently in a specific application. Efficiency of the pump controls allows down-sizing of system cooling needs, saving up front cost in the machine. Alternatively, cooling capacity could be kept the same and the flow capa-bility of the system increased, thus improving per-formance and customer satisfaction.
The M Series also contains a strong proven rotat-ing group allowing the pumps to handle pressures to 315 bar (4568 psi) continuous with less main-tenance cost. High-load bearings and a stiff drive shaft help provide a pump life of 8000 hours at rated industrial conditions, reducing operating costs and extending operating life.
M Series pumps feature a saddle-type yoke with steel-backed polymer bearings. The stiff yoke reduces deflection and allows even loading of bear-ings, improving life. A single control piston reduces loading on the yoke, resulting in reduced pump size which allows installation in tighter locations.
M Series pumps operate at a level of quietness that exceeds the requirements of today’s demanding work conditions. The pumps feature a unique three-piece envelope (flange, housing and valve block) specifically created for low fluid-borne and struc-ture-borne noise levels. Another pump feature – a bimetal timing plate – improves pump filling charac-teristics which, in turn, reduce fluid-borne noise and extend pump life.
M Series pumps reduce, or in some cases remove, the need for damping barriers between the noise source and the operator. This saves money on the installed cost of the system while improving cus-tomer comfort.
An adjustable maximum stop provides a means of tuning flow to your system, while gauge ports allow monitoring of inlet and outlet conditions. These standard features reduce system complexity and cost.
Mounting flanges are offered in SAE and ISO con-fig urations, and ports are offered in SAE, ISO, and BSPP in both tube and flange versions. This pro-
vides a wide variety of installation opportunities for global machine design.
Side- or end-ported models are available to facilitate plumbing and help fit the pump to your machine space needs. Multiple drain ports allow many mounting orientations, reducing installed costs.
M Series pumps are capable of operating with many types of hydraulic fluids used in industrial sys-tems. High-water-content and phosphate ester flu-ids can be accommodated, in addition to the typical petroleum based and synthetic fluids.
Typical Applications
• Mining machinery
• Injection molding machines
• Metal forming machines
• Oil and Gas Equipment
• Conveyor lines
• Primary metals
• Metal cutting equipment
Features and Benefits
• Long pump life
• Quiet pump operation
• Inlet and outlet gauge ports and adjustable maximum displacement stops – standards
• Astonishingly low 4% pressure ripple
• Low installed and operating costs
• Reduced maintenance
• Flexibility in machine design
• Design promotes leak-free system
4EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Hydraulic System Design Calculations
Basic Formulas
Output Flow (Q)
lpm = gpm =
Input Power (P)
kW = hp =
Shaft Torque (M)
N-m = lb-in =
Shaft Speed (n)
rpm = RPM =
Output Power (P)
kW = hp =
Volumetric Displacement
cm3/r = in3/r =
Basic Formulasbar = 10 Newtons/cm2
gpm = gallons per minute
hp = horsepower
lb-in = pound inch
lb-ft = pound feet
kW = kilowatt
kgf = kilograms force
l/min = liters per minute
N-m = Newton meters
psi = pounds per square inch
rpm = revolutions per minute
EfficienciesVolumetric Nv =
Mechanical Nm =
Total Nt = Nv x Nm
Commonly Used ConversionsTo Convert Into Multiply by
bar psi 14.5
cm3 in3 0.06102
˚C ˚F (˚C x 1.8) +32
gallons (US) liters 3.785
kg lbs 2.205
kgf/cm2 psi 14.2
kW hp 1.341
liters US Gallons 0.2642
mm inches 0.03937
N-m lb-in 8.85
N-m lb-ft 0.7375
˚F ˚C (˚F-32)/1.8
hp kW 0.7457
inch mm 2.54
in3 cm3 16.39
lb-in N-m 0.113
lb-ft N-m 1.356
lbs kg 0.4535
psi bar 0.06896
psi kgf/cm2 .070307
Note: Performance charts can be found on subsequent pages.
cm3/r x rpm in3/r x rpm
1000 231
l/min x bar gpm x psi
600 1714
bar x cm3/r psi x in3/r
62.8 6.28
1000 x 1/min 231 x gpm
cm3/r in3/r
N-m x RPM lb-in x rpm
9549 63,025
lpm x 1000 gpm x 231
rpm rpm
PM
n
Q
p
gpm actual
gpm theorectical
lb-in actual
lb-in theorectical
5 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Model Code Selection
1, 2, 3 Product SeriesPVM – M Series Variable
Piston Pump
4, 5, 6 DisplacementTwelve displacements available 230 bar and 315 bar continuous ratings
7 Valve PlateE - Quiet version, optimized for 1000-1800 rpm
M - Higher speed version
ref speed performance data for individual dispalcements
8 Input Rotation
R – Clockwise (Righthand) L* – Counter-clockwise
(Lefthand)
9, 10 Input ShaftStandard SAE and ISO splined versions (Other configurations optional)
11 Mounting FlangeThirteen options in SAE and ISO mounts
12 Main Port LocationE** – End Ported S**** – Side Ported
13, 14 Main Port Type SAE & ISO tube ports and 4-bolt flange (Other configurations optional)
15, 16 Pump Special Features
00 – None AA – Adjustable Maximum
Displacement Stop and single shaft (standard)
AB – Double Shaft Seal, Two Way
17 Control 0 – None A – Pressure Compensator B – Pressure and Flow
Compensator with Bleed Orifice
C – Pressure and Flow Compensator with Plugged Orifice
E – Industrial/Remote (57cc through 141 cc only)
L - Power Control with Load Sense and Pressure compensator with Plugged Orifice (74,81 cc only, other displacements 57 cc through 141cc under development)
18, 19 Pressure Compensator Setting
00 – None 07 – 70 bar (Adjustable
between 40 bar and 130 bar)
23 – 230 bar (Adjustable between 130 bar and 320 bar)
28 – 280 bar (Adjustable between 130 bar and 320 bar)
20, 21 Flow Compensator Setting
00 – None 11 – 11 bar setting 20 – 20-20 bar setting 24 – 24-24 bar setting
22, 23 Power control Torque Limiter
Setting00 – None
50-50% of rated torque*
(adjustable from 20-90% of rated torque,*for any other values specify % of rated torque )
24 Compensator Special Features
0 – None
25 Auxiliary Mounting Pad0*** – None
(Auxiliary mounting available on all frame sizes)
26 Paint0 – No Paint A – Standard Blue Paint
27 Customer Identification0 – None (Contact Eaton
for Options)
28 Design CodeA – A (Initial Release)
PVM 045 E R 01 A E 01 AA A 28 00 00 0 0 A 0 A
1, 2, 3 13, 149, 10 15, 16 18, 19 20, 21 22, 234, 5, 6 7 8 11 12 17 24 25 26 27 28
* Not available on 074, 081, 098 and 106 End Port
** Not available on 074, 081, 098 and 106 LH
*** Through drive not available on the LH
**** Not available on 018
6EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Model Code Options
4,5,6 Maximum Geometric Displacement
Displacement Code 018 020 045 050 057 063 074 081 098 106 131 141cm3/r 18,0 21,1 45,1 50,0 57,4 63,1 73,7 81,0 98,3 106,5 131,1 141,0in3/r 1.1 1.29 2.75 3.05 3.50 3.85 4.50 4.94 6.00 6.50 8.00 8.60
11 Mounting Flange Specifications
Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141A SAE A, 2-bolt B ISO 80A2HW C SAE B, 2-bolt D ISO 100A2HW E SAE C, 2-bolt F ISO 125-A2HW G SAE C, 4-bolt H ISO 125B4HW J SAE D, 4-bolt K ISO 160B4HW
= Available
= Not Available
9,10 Shaft-End Type at Electric Motor End
Shaft CodeDescription PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141SAE, SAE A, Straight Keyed 01 – – – – –SAE, SAE 19-1, Straight Keyed 02 – – – – –SAE, SAE A, 9T Spline 03 – – – – –SAE, SAE A, 11T Spline 04 – – – – –SAE, SAE B, Straight Keyed 05 05 – – – –SAE, SAE B-B, Straight Keyed 06 06 06 – – –SAE, SAE B, 13T Spline 07 07 07 – – –SAE, SAE B-B, 15T Spline 08 08 08 – – –SAE, SAE C, Straight Keyed – – 09 09 09 09SAE, SAE C-C, Straight Keyed – – – 10 10 10SAE, SAE C, 14T Spline – – 11 11 11 11SAE, SAE C-C, 17T Spline – – – 12 12 12SAE, SAE D, Straight Keyed – – – – – 13SAE, SAE D, 13T Spline – – – – – 14ISO E20N, Straight Keyed 15 – – – – –ISO E25N, Straight Keyed, Short Spigot 16 – – – – –ISO E25N, Straight Keyed 17 17 17 – – –ISO E32N, Straight Keyed, Short Spigot – – 18 18 18 18ISO E40N, Straight Keyed, Short Spigot – – – 19 19 19
7 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Model Code Options
13,14 Main Port Options
Inlet Code Description Outlet PVM018/020 PVM045/050 PVM057/063 PVM074/081 PVM098/106 PVM131/141 Inlet –20 –24 –24 – – –
01 SAE J1926 (End ports only) Tube Ports Outlet –12 –16 –16 – – – (End ports only)
02 SAE J518 Inlet 1.25 inch 2.0 inch 2.0 inch 2.0 inch 2.5 inch 2.5 inch
Flange Ports Outlet 0.75 inch 1.0 inch 1.0 inch 1.0 inch 1.0 inch 1.25 inch* Inlet M42 M48 M48 – – –
03 ISO 6149-1 (End ports only) Tube Ports Outlet M27 M33 M33 – – – (End ports only)
04 ISO 6162 Inlet 32mm 51mm 51mm 51mm 64mm 64mm
Flange Ports Outlet 19mm 25mm 25mm 25mm 25mm 32mm* British Standard 05 Parallel Pipe – Inlet G 1-1/4 G 1-1/2 – – – – Tube Ports Outlet G 3/4 G 1 – – – –*SAE Code 62, high pressure series, or ISO 400 bar. Other flange ports are SAE Code 61, standard pressure series, or ISO 25-350 bar.
25 Thru-Drive Options
Code Description PVM018/020 PVM045/050 PVM057/063 PVM074/081* PVM098/106 PVM131/141O Single pump,
non-thru-drive A SAE A, 2-bolt,
9T spline B SAE A, 2-bolt,
11T spline C SAE B, 2-/4-bolt,
13T spline D SAE B-B, 2-/4-bolt,
15T spline E SAE C, 2-/4-bolt,
14T spline F SAE C-C, 2-/4-bolt,
17T spline G ISO 80-A2HW,
9T SAE spline H ISO 80-A2HW,
11T SAE spline J ISO 100-A2/B4HW,
13T SAE spline K ISO 100-A2/B4HW,
15T SAE spline L ISO 125-A2/B4HW,
14T SAE spline M ISO 125-A2/B4HW,
17T SAE spline
= Available
= Not Available
* Not available on the 074/081 LH
8EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Specifications and PerformanceQuiet version, optimized for 1000-1800 rpm (E)
Displacement, Pressure and Flow Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Maximum Maximum Flow at 280 bar (4000 psi)* Geometric Maximum Pressure bar (psi) l/min (USgpm) – Average measured flow rate Displacement @1800 @1500 @1200 @1000 Model Series cm3/r (in3/r) Nominal Peak** r/min r/min r/min r/minPVM018 18 (1.1) 315 (4568) 350 (5000) 31 (8.2) 26 (7) 21 (5.5) 17 (4.5)PVM020 21,1 (1.29) 230 (3300) 280 (4000) 35 (9) 29 (8) 23 (6) 19 (5)PVM045 45,1 (2.75) 315 (4568) 350 (5000) 76 (20) 65 (17) 49 (13) 42 (11)PVM050 50,0 (3.05) 230 (3300) 280 (4000) 87 (23) 75 (20) 62 (16) 49 (13)PVM057 57,4 (3.50) 315 (4568) 350 (5000) 102 (27) 85 (22.4) 66 (17.4) 54 (14.3)PVM063 63,1 (3.85) 230 (3300) 280 (4000) 111 (29) 93 (24) 74 (19) 60 (16)PVM074 73,7 (4.50) 315 (4568) 350 (5000) 127 (33.5) 106 (28) 86 (22.7) 70 (18.5)PVM081 81,0 (4.94) 230 (3300) 280 (4000) 139 (37) 116 (31) 93 (25) 76 (20)PVM098 98,3 (6.00) 315 (4568) 350 (5000) 170 (45) 141 (37) 112 (29.6) 92 (24.3)PVM106 106,5 (6.50) 230 (3300) 280 (4000) 187 (49) 155 (41) 123 (32) 102 (27)PVM131 131,1 (8.00) 315 (4568) 350 (5000) 215 (57) 178 (47) 141 (37) 118 (31)PVM141 141,0 (8.60) 230 (3300) 280 (4000) 238 (63) 199 (53) 158 (42) 131 (35)
**Momentary system pressure spikes only.
Speed, Input Power and Torque Ratings At 50°C (120°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Maximum Maximum Torque at Operating 280 bar Approximate Model Speed Maximum Input Power at 280 bar (4000 psi) kw (hp)*@88% M.E. (4000 psi)* WeightSeries r/min @1800 r/min @1500 r/min @1200 r/min @ 1000 r/min Nm (lb-ft) kg (lb)PVM018 1800 16 (22) 13 (18) 11 (15) 9 (12) 84 (62) 15 (33)PVM020 1800 14 (18) 11 (15) 9 (12) 8 (10) 73 (54) 15 (33) PVM045 1800 41 (55) 34 (46) 27 (37) 23 (31) 221 (163) 24 (52)PVM050 1800 35 (47) 30 (40) 28 (38) 23 (31) 190 (140) 24 (52)PVM057 1800 52 (70) 44 (59) 36 (49) 29 (39) 272 (201) 36 (79)PVM063 1800 42 (57) 36 (48) 29 (39) 24 (32) 228 (168) 36 (79)PVM074 1800 63 (84) 52 (70) 42 (56) 35 (47) 334 (246) 45 (99)PVM081 1800 56 (75) 46 (62) 35 (47) 28 (37) 286 (211) 45 (99)PVM098 1800 88 (118) 72 (97) 58 (78) 48 (64) 464 (342) 55 (121)PVM106 1800 72 (97) 60 (80) 48 (64) 40 (54) 383 (282) 55 (121)PVM131 1800 113 (152) 94 (126) 75 (101) 63 (85) 596 (440) 66 (145)PVM141 1800 94 (126) 79 (106) 63 (85) 53 (71) 497 (367) 66 (145)
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)PVM018 30 25PVM020 39 26PVM045 140 40PVM050 140 40PVM057 65 20PVM063 85 20* 3300 psi on overbore pumps
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)PVM074 85 30PVM081 85 30PVM098 65 25PVM106 72 29PVM131 135 30PVM141 100 30*Values with pressure compensator control.
9 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Specifications and PerformanceHigher speed version (M)
Displacement, Pressure and Flow Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Geometric Maximum Pressure bar (psi) Maximum Flow at 280 bar (4000 psi) Displacement Flange Ports Tube Ports Model Series cm3/r (in3/r) Nominal Peak** l/min (USgpm) @ 1 bar inlet l/min (USgpm) @ 1 bar inletPVM018 18,0 (1.10) 315 (4568) 350 (5000) 46 (12) @ 2800 r/min 46 (12) @ 2800 r/minPVM020 20,1 (1.22) 230 (3300) 280 (4000) 53 (14) @ 2800 r/min 53 (14) @ 2800 r/minPVM045 45,1 (2.75) 315 (4568) 350 (5000) 115 (30) @ 2600 r/min 106 (28) @ 2400 r/minPVM050 50,0 (3.05) 230 (3300) 280 (4000) 125 (33) @ 2600 r/min 116 (31) @ 2400 r/minPVM057 57,4 (3.50) 315 (4568) 350 (5000) 140 (37) @ 2500 r/min 128 (34) @ 2300 r/minPVM063 63,1 (3.85) 230 (3300) 280 (4000) 150 (40) @ 2500 r/min 140 (37) @ 2400 r/minPVM074 73,7 (4.50) 315 (4568) 350 (5000) 163 (43) @ 2400 r/min –PVM081 81,0 (4.94) 230 (3300) 280 (4000) 181 (48) @ 2400 r/min –PVM098 98,3 (6.00) 315 (4568) 350 (5000) 200 (53) @ 2200 r/min –PVM106 106,5 (6.50) 230 (3300) 280 (4000) 222 (59) @ 2200 r/min –PVM131 131,1 (8.00) 315 (4568) 350 (5000) 233 (62) @ 2000 r/min –PVM141 141,0 (8.60) 230 (3300) 280 (4000) 258 (68) @ 2000 r/min – **Less than 0.5 second.
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)PVM018 50 20PVM020 57 22PVM045 140 40PVM050 140 23PVM057 65 20PVM063 94 20
Standard Response Times*
Model Series On Stroke (msec) Off Stroke (msec)PVM074 95 30PVM081 135 30PVM098 85 24PVM106 90 25PVM131 100 30PVM141 128 28*Values with pressure compensator control.
10EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Specifications and PerformanceHigher speed version (M)
Speed, Input Power and Torque Ratings At 93°C (200°F), SAE 10W oil, 1 bar absolute (0 psig) inlet
Operating Speed and Pressure r/min Max. Input Power at Max. Torque at Approximate 1 bar Inlet 0,85 bar Inlet Max. Speed and 280 bar 280 bar (4000 psi) Weight (dry)Model Series Flange Ports Tube Ports Flange Ports (4000 psi) kW (hp) Nm (lb-ft) kg (lbs) 2800 r/min 24 (32)PVM018 2800 r/min 24 (32) 82 (60) 15 (33) 2600 r/min 22 (30) 2800 r/min 21 (28)PVM020 2800 r/min 21 (28) 72 (53) 15 (33) 2600 r/min 20 (27) 2600 r/min 56 (75)PVM045 2400 r/min 53 (71) 198 (46) 24 (52) 2200 r/min 48 (64) 2600 r/min 51 (68)PVM050 2400 r/min 48 (64) 204 (150) 24 (52) 2200 r/min 44 (59) 2500 r/min 68 (91)PVM057 2300 r/min 62 (83) 262 (193) 36 (79) 2100 r/min 56 (75) 2500 r/min 59 (79)PVM063 2400 r/min 57 (76) 225 (166) 36 (79) 2200 r/min 52 (69)
PVM074 2400 r/min 84 (113)
334 (246) 45 (99) 1900 r/min 69 (93)
PVM081 2400 r/min 69 (93)
276 (204) 45 (99) 1900 r/min 55 (74)
PVM098 2200 r/min 105 (141)
457 (337) 55 (121) 1800 r/min 86 (115)
PVM106 2200 r/min 87 (117)
377 (278) 55 (121) 1800 r/min 70 (94)
PVM131 2000 r/min 122 (164)
581 (429) 66 (145) 1600 r/min 98 (131)
PVM141 2000 r/min 102 (137)
483 (356) 66 (145) 1600 r/min 81 (109)
11 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Specifications and PerformanceVariable Speed Drive
Variable Speed Performance- System Pressure vs Speed
Model Max Speed Max Speed Min Speed Nominal Peak Inertia Series “E”* (rpm) “M”*(rpm) (rpm) Pressure (bar) Pressure (bar) ** (kg-cm2)
PVM018 1800 2800 0 315 350 11.8PVM020 1800 2800 0 230 280 11.8PVM045 1800 2600 0 315 350 36.2PVM050 1800 2600 0 230 280 33.9PVM057 1800 2500 0 315 350 51.6PVM063 1800 2500 0 230 280 50.5PVM074 1800 2400 0 315 350 78.1PVM081 1800 2400 0 230 280 72.7PVM098 1800 2200 0 315 350 131.6PVM106 1800 2200 0 230 280 122.7PVM131 1800 2000 0 315 350 213.5PVM141 1800 2000 0 230 280 209.7* Valve plate type **Less than 0.5 second.
PVM System Pressure vs. Shaft Speed
0
50
100
150
200
250
300
350
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800
Syst
em P
ress
ure
(bar
)
Shaft Speed (rpm)
230 bar (over-bore displacements) - PVM20, 50, 63, 81, 106, 141(max speed varies by displacement)
315 bar (standard-bore displacements) - PVM18, 45, 57, 74, 98, 131(max speed varies by displacement)
Max Speed Rating:1. Standard speed version "E" - Optimzed for low sound, 1800 RPM for all displacements2. High speed version "M" - up to 2800 RPM depending on displacement. See spec for details.
Test condition: Mineral oil SAE 10W, oil temperature 49º C (120º F), 1 bar absolute inlet pressure.
12 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Control Options
Pressure Compensator Control – Code A
The pump will provide a con-tinuously modulated flow to meet changing load demands at a pre-adjusted compensa-tor pressure. At pressures below the compensator set-ting, the pump will operate at maximum displacement. See model code on page 4 for compensator pressure ranges.
Warning: The pressure com-pensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a 0-350 bar (0-5000 psi) gage in the outlet gage port and limit the pressure setting to the con-tinuous rated pressure for the pump displacement shown on page 7.
Industrial Pressure Cut-off Characteristics of Code A Pressure Compensator Control at 50°C (120°F), static conditions.
“K” inlet gage port
“K” outlet gage port
“B” inlet
“F” case drain
“C” outlet
To load
•
•
•
•
•
See model code on page xx for spring (pressure) adjustment ranges.
•�
�
Change in Pressure A
Pressure Cut-off Characteristics of Code A Pressure Compensator Control @ 50C (120F), 1800 r/min, static conditions
Outlet Pressure
Change in Flow B
Q
P
Outle
t Flo
w
Pressure Cut-off Characteristics of Pressure Compensator Control @ 50°C (120°F), Static Conditions
“P” Outlet Max. Speed “Q” Outlet Flow Pressure A B Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)PVM018 1800 32 (8.5) 315 (4568) 2,8 (40) 4,5 (1.2)PVM020 1800 35 (9.25) 230 (3300) 2,8 (40) 4,5 (1.2)PVM045 1800 76 (20) 315 (4568) 10 (150) 4,5 (1.2)PVM050 1800 87 (23) 230 (3300) 10 (150) 4,5 (1.2)PVM057 1800 102 (27) 315 (4568) 3,5 (51) 14 (3.7)PVM063 1800 113 (29) 230 (3300) 7,4 (107) 7,6 (2.00)PVM074 1800 127 (33.5) 315 (4568) 1,5 (22) 37 (9.8)PVM081 1800 141 (37) 230 (3300) 1,5 (22) 37 (9.8)PVM098 1800 179 (47) 315 (4568) 1,5 (22) 25 (6.6)PVM106 1800 195 (51.5) 230 (3300) 1,5 (22) 20 (5.3)PVM131 1800 229 (60.5) 315 (4568) 3,5 (51) 19 (5.0)PVM141 1800 238 (63) 230 (3300) 3,5 (51) 14 (3.70)
“K” inlet gage port
“K” outlet gage port
“B” inlet
“F” case drain
“C” outlet
To load
•
•
•
•
•
See model code on page xx for spring (pressure) adjustment ranges.
•�
�
Change in Pressure A
Pressure Cut-off Characteristics of Code A Pressure Compensator Control @ 50°C (120°F), 1800 r/min, static conditions
Outlet Pressure
Change in Flow B
Q
P
Outle
t Flo
w
13EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Control Options
Mobil Pressure Cut-off Characteristics of Pressure Compensator Control at 93°C (200°F), static conditions.
“K” inlet gage port
“B” inlet
“F” case drain
“C” outlet
To load
åÅ•
åÅ•
åÅ•
åÅ•
åÅ•
See model code on page 5 for spring (pressure) adjustment ranges.
åÅ•
� “K” outlet gage port
Change in Pressure A
Outlet Pressure
Outle
t Flo
w Change
in Flow B
Q
P
+
+
Pressure Cut-off Characteristics of Pressure Compensator Control @ 93°C (200°F), Static Conditions
“P” Outlet Rated Speed “Q” Outlet Flow Pressure A B Model Series r/min l/min (USgpm) bar (psi) bar (psi) L/min (USgpm)PVM018 2800 42 (11) 315 (4568) 2,8 (40) 4,5 (1.2)PVM020 2800 52 (14) 230 (3300) 2,8 (41) 4,5 (1.2)PVM045 2600 115 (30) 315 (4568) 10 (150) 4,5 (1.2)PVM050 2600 125 (33) 230 (3300) 10 (150) 4,5 (1.2)PVM057 2500 140 (37) 315 (4568) 3,5 (50) 14 (3.7)PVM063 2500 159 (42) 230 (3300) 7,4 (107) 11,4 (3.00)PVM074 2400 174 (46) 315 (4568) 1,5 (20) 37 (9.8)PVM081 2400 185 (49) 230 (3300) 1,5 (22) 37 (9.8)PVM098 2200 217 (57) 315 (4568) 1,5 (20) 32 (8.4)PVM106 2200 234 (62) 230 (3300) 1,5 (22) 24 (6.33)PVM131 2000 253 (67) 315 (4568) 1,0 (15) 23 (6.0)PVM141 2000 258 (68) 230 (3300) 7,0 (100) 14 (3.70)
14 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Control Options
Load Sensing and Pressure Compensator Control – Code B or C
The pump will provide power matching of pump output to system load demand, maximiz-ing efficiency and improving load metering characteristics of any directional control valve installed between the pump and the load.
Load sensing ensures that the pump always provides only the amount of flow needed by the load. At the same time, the pump operating pressure adjusts to the actual load pres-sure plus a pressure differ-ential required for the control action. When the system is not demanding power, the load sense control will operate in an energy-saving stand-by mode.
Typically, the differential pres-sure is that between the pres-sure inlet and service port of a proportionally controlled direc-tional valve, or a load sensing directional control valve. See the model code on page 4 for differential pressure settings for load sensing.
If the load pressure exceeds the system pressure setting, the pressure compensator de-strokes the pump. The load sensing line must be as short as possible and can also be used for remote control or unloading of the pump pressure. For remote control purposes, it is recommended that you contact your Eaton representative for the correct configuration of the control.
Warning: The pressure com-pensator may be adjusted beyond the rated pressure of the pump. When adjusting the pressure limiter, install a 0-350 bar (0-5000 psi) gage in the outlet gage port and limit the pressure setting to the continuous rated pressure for the pump displacement shown on page 7.
•
“K” outlet gage port
“B” inlet
“F” case drain
“C” outlet
To load
•
•
•
•
• •
•
•
“J” load sensesignal port
Optional bleed-down orifice in Code Bcontrol. ∆ 0,4 mm (.016 in.) Orifice is plugged for no bleed down in control Code C.
•�
�
“K” inlet gage port
15EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Control Options
Inlet
Case drain
Outlet
To load
Load sensesignal port
Tank port
Pressureport
Inlet
Case drain
Outlet
To load
Load sensesignal port
Tank port
Pressureport
This pump is intended for use when multiple, remote, or electronically controlled compensating settings, with or without load sensing, are desired.
Pressure compensation is obtained when an internal plug is removed, the load-sense signal port is kept plugged, and internal pilot pressure is applied to the spring cham-ber of the control spool. For pressure compensation with load sensing, the internal plug stays, the load-sense signal port is unplugged, and pilot pressure is externally applied.
An external relief valve (not supplied) controls spring chamber pressure. The exter-nally adjustable spring deter-mines the differential pressure setting of the control. Outlet pressure is limited to the valve of the spring chamber (pres-sure port) pressure, plus con-trol differential pressure.
Spring chamber (pilot) pres-sure is separated from outlet pressure by an internal orifice. Outlet pressure shifts the spool when pressure drop across the orifice reaches the differential pressure setting, and the pump de-strokes.
The relief valve can be mount-ed to an NFPA-D03/ISO 4401-03 pad on the pump control, or remotely located via tapping and blanking plates installed on the pad. See “Ordering Procedure”, page 27, for more on valves and plates.
The standard factory-set dif-ferential pressure setting of the pump control is 20 bar (290 psi) and is not specified in the pump model number. Any other ordered differential pressure, within the control’s adjustable pressure range of 17-35 bar (247-508 psi), will be specified in the model number.
Industrial Control Compensator – Code E & F (Model 057-141 only) With Pressure & Flow Compensator (E)
Pressure Compensating Without Load Sensing (F)
Inlet
Case drain
Outlet
To load
Load sensesignal port
Tank port
Pressureport
Inlet
Case drain
Outlet
To load
Load sensesignal port
Tank port
Pressureport
16EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Control Options
Power Control-Code L
The Power control limits the maximum torque output by the piston pump by reducing the displacement as pressure increases hence limiting the power rating at a given speed.
As pressure increases the pump displacement is reduced such that the set torque value is not exceeded.
The torque can be set between 20-90% of rated torque for given displacement at 1800 rpm (model code pos 22-23, ref table below for range of torque.
Warning: The pressure com-pensator may be adjusted beyond the rated pressure of the pump.When adjusting the pressure limiter, install a 0-350 bar (0-5000 psi) gage in the outlet gage port and limit the pressure setting to the con-tinuous rated pressure for the pump displacement shown on page 7.
Torque setting range by displacemnent
Displacement (cc) Rated Torque Min torque setting Max torque setting lb-in (N-m) lb-in (N-m), 20% lb-in (N-m), 90% of rated torque* of rated torque
74 2920 (330) 584 (66) 2628 (297)
81 2626 (297) 525 (59) 2363 (267)
* for Minimum torque setting (20%) the pump may not deliver the flow at higher pressure. Please contact Eaton Engineering for flow generated at max pressure
20%
35%
50%
65%
85%90%
0
0.2
0.4
0.6
0.8
1
1.2
0 0.2 0.4 0.6 0.8 1
Dis
plac
emen
t (1/
Dm
ax)
Pressure (1/ Pmax)
Flow Vs Pressure
20%
35%
50%
65%
85%90%
0.00
0.20
0.40
0.60
0.80
1.00
0 0.2 0.4 0.6 0.8 1
Torq
ue (1
/Tm
ax)
Pressure (1/ Pmax)
Torque Vs Pressure
`
Characteristics of Code L Power Control at 50°C (120°F), static conditions.
Pressure (1/Pmax)
Dis
plac
emen
t (1
/Dm
ax)
Torq
ue(1
/Tm
ax)
Pressure (1/Pmax)
17 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Performance Quiet version, optimized for 1000-1800 rpm (E), PVM074/PVM081 Power Control -code L
Mineral oil SAE 10W, oil temperature 49º C (120º F), 1 bar absolute inlet pressure. Curves plotted at load sense delta P = 24 bar
Mineral oil SAE 10W, oil temperature 49º C (120º F), 1 bar absolute inlet pressure. Curves plotted at load sense delta P = 24 bar
20%
30%
40%50%60%
70%80%90%
0 50 100 150 200 250
0
20
40
60
80
100
120
140
0
5
10
15
20
25
30
35
40
0 500 1000 1500 2000 2500 3000 3500 4000
Pressure (bar)
Flow
(lpm
)
Flow
(gpm
)
Pressure (PSI)
Flow Vs Pressure - 81cc
Mineral oil SAE 10W, oil temperature 49º C (120º F), 1 bar absolute inlet pressure. Curves plotted at load sense delta P = 24 bar
Mineral oil SAE 10W, oil temperature 49º C (120º F), 1 bar absolute inlet pressure. Curves plotted at load sense delta P = 24 bar
Performance curves for 74 & 81 cc with power control, at various torque setting %
20%
30%
40%
50%
60%
70%
80%
90%
0 50 100 150 200 250
0
50
100
150
200
250
0
500
1000
1500
2000
2500
0 500 1000 1500 2000 2500 3000 3500 4000
Pressure (bar)
Torq
ue (N
-m)
Torq
ue (l
b-in
)
Pressure (PSI)
Torque Vs Pressure - 81cc
20% 30%
40%50%60%
70%
80%90%
0 50 100 150 200 250 300
0
20
40
60
80
100
120
0
5
10
15
20
25
30
35
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Pressure (bar)
Flow
(lpm
)
Flow
(gpm
)
Pressure (PSI)
Flow Vs Pressure - 74cc
20%
30%
40%
50%
60%
70%80%
90%
0 50 100 150 200 250 300
0
50
100
150
200
250
300
0
500
1000
1500
2000
2500
3000
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Pressure (bar)
Torq
ue (N
-m)
Torq
ue (l
b-
in)
Pressure (PSI)
Torque Vs Pressure - 74cc
18 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceIndustrial PVM018
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
46
50
52
56
60
66
48
54
58
64
62
44
46
50
54
60
62
42
48
52
58
56
1800 r/minmin. flow
1200 r/minmax. flow
1800 r/minmax. flow
Typical Noise Levels at 1800 and 1200 r/min withPetroleum Oil (10W) at 50°C (120°F) and 1.0 barabsolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min withPetroleum Oil (10W) at 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Sound pressure dataequivalent to NFPA.
1200 r/minmin. flow
1000 r/minmin. flow
1000 r/minmax. flow
1500 r/minmin. flow
1500 r/minmax. flow
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
Inpu
t Tor
que
– N
m (i
n-lb
)
20 (27)
15 (20)
10 (13)
5 (7)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
40 (11)
30 (8)
20 (5)
10 (3)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
46
50
52
56
60
66
48
54
58
64
62
44
46
50
54
60
62
42
48
52
58
56
1800 r/minmin. flow
1200 r/minmax. flow
1800 r/minmax. flow
Typical Noise Levels at 1800 and 1200 r/min withPetroleum Oil (10W) at 50°C (120°F) and 1.0 barabsolute (0 psi gauge) Inlet
Typical Noise Levels at 1500 and 1000 r/min withPetroleum Oil (10W) at 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Sound pressure dataequivalent to NFPA.
1200 r/minmin. flow
1000 r/minmin. flow
1000 r/minmax. flow
1500 r/minmin. flow
1500 r/minmax. flow
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
Inpu
t Tor
que
– N
m (i
n-lb
)
20 (27)
15 (20)
10 (13)
5 (7)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
40 (11)
30 (8)
20 (5)
10 (3)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
19EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Inpu
t Tor
que
– N
m (i
n.lb
.)Ef
ficie
ncy
– %
Deliv
ery
– l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
Delivery and Efficiency at 1500 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
Overall Efficiency
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Inpu
t Tor
que
– N
m (i
n.lb
.)Ef
ficie
ncy
– %
Deliv
ery
– l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
Delivery and Efficiency at 1500 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
Overall Efficiency
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
30 (8)
20 (5)
10 (3)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)In
put T
orqu
e –
Nm
(in.
lb.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM018
20 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Effic
ienc
y –
%
Deliv
ery
– l/m
in (U
Sgpm
)
Inpu
t to0
rque
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.11)
0,2 (0.05)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Effic
ienc
y –
%
Deliv
ery
– l/m
in (U
Sgpm
)
Inpu
t to0
rque
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
20 (5)
10 (3)
0
Volumetric Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Overall Efficiency
100 (885)
90 (796)
80 (708)
70 (619)
60 (531)
50 (442)
40 (354)
30 (265)
20 (177)
10 (88)
0
20 (27)
15 (20)
10 (13)
5 (7)
0
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.11)
0,2 (0.05)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM018
21EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM018
76
72
68
64
60
56
52
48
44
40
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
600 r/minMin. Flow
600 r/minMax. Flow
2800 r/minMin. Flow
2800 r/minMax. Flow
350(5000)
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 500 1000 1500 2000 2500 3000
Effic
ienc
y –
%
Speed – r/min
200 bar(2900 psi)
100 bar(1500 psi)
320 bar (4600 psi)
280 bar(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
250 bar(3600 psi)
76
72
68
64
60
56
52
48
44
40
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
600 r/minMin. Flow
600 r/minMax. Flow
2800 r/minMin. Flow
2800 r/minMax. Flow
350(5000)
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 500 1000 1500 2000 2500 3000
Effic
ienc
y –
%
Speed – r/min
200 bar(2900 psi)
100 bar(1500 psi)
320 bar (4600 psi)
280 bar(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
250 bar(3600 psi)
40 (10.6)
20 (5.3)
00 500 1000 1500 2000 2500
1,0 (.3)
3,0 (.8)
4,0 (1.1)
Speed – r/min
Deliv
ery
– l/m
in (U
Sgpm
)In
put T
orqu
e –
Nm
(in.
lb.)
Case
Flo
w –
l/m
in (U
Sgpm
)
25 bar (365 psi),Delivery
250 bar (3600 psi),Delivery
25 bar (365 psi), Case flow
10 (2.6)
30 (7.9)
50 (13.2)
03000
35 (9.2)
15 (4.0)
5 (1.3)
25 (5.3)
45 (11.9)
2,0 (.5)
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
Input Torque Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
00 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
90 (796)
10 (88)
100 bar (1500 psi)
50 (442)
20 (177)
40 (354)
30 (265)
110 (973)
60 (531)
70 (619)
100 (885)
80 (708)
320 bar (4600 psi)
250 bar (3600 psi), Case flow
40 (10.6)
20 (5.3)
00 500 1000 1500 2000 2500
1,0 (.3)
3,0 (.8)
4,0 (1.1)
Speed – r/min
Deliv
ery
– l/m
in (U
Sgpm
)In
put T
orqu
e –
Nm
(in.
lb.)
Case
Flo
w –
l/m
in (U
Sgpm
)
25 bar (365 psi),Delivery
250 bar (3600 psi),Delivery
25 bar (365 psi), Case flow
10 (2.6)
30 (7.9)
50 (13.2)
03000
35 (9.2)
15 (4.0)
5 (1.3)
25 (5.3)
45 (11.9)
2,0 (.5)
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
Input Torque Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
00 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
90 (796)
10 (88)
100 bar (1500 psi)
50 (442)
20 (177)
40 (354)
30 (265)
110 (973)
60 (531)
70 (619)
100 (885)
80 (708)
320 bar (4600 psi)
250 bar (3600 psi), Case flow
22 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM018
0 500 1000 1500 2000 2500 3000
Inpu
t Pow
er @
Ful
l Flo
w –
kW
(hp)
Speed – r/min
280 bar (4000 psi)250 bar (3600 psi)
200 bar (2900 psi)
150 bar (2200 psi)
100 bar (1500 psi)
25 bar (365 psi)
320 bar (4600 psi)
28 (37.5)
24 (32.2)
20 (26.8)
16 (21.4)
12 (16.1)
8 (10.7)
4 (5.4)
2 (2.7)
6 (8.0)
10 (13.4)
14 (18.8)
18 (24.1)
22 (29.5)
26 (34.9)
0
Input Power Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential, Case Flow
0 500 1000 1500 2000 2500 3000
20 bar (300 psi)differential,Input Torque
11 bar (160 psi) differential,Input Torque 11 bar (160 psi)
differential,Case Flow
Input Torque and Case Flow Versus Speed @ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
Inpu
t Tor
que
- Nm
(in.
lb.)
Case
Flo
w (l
/min
(USg
pm)
2 (0.53)
4 (1.06)
2 (18)
3 (27)
1 (9) 5 (1.32)
1 (0.26)
3 (0.79)
00
0 500 1000 1500 2000 2500 3000
Inpu
t Pow
er @
Ful
l Flo
w –
kW
(hp)
Speed – r/min
280 bar (4000 psi)250 bar (3600 psi)
200 bar (2900 psi)
150 bar (2200 psi)
100 bar (1500 psi)
25 bar (365 psi)
320 bar (4600 psi)
28 (37.5)
24 (32.2)
20 (26.8)
16 (21.4)
12 (16.1)
8 (10.7)
4 (5.4)
2 (2.7)
6 (8.0)
10 (13.4)
14 (18.8)
18 (24.1)
22 (29.5)
26 (34.9)
0
Input Power Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential, Case Flow
0 500 1000 1500 2000 2500 3000
20 bar (300 psi)differential,Input Torque
11 bar (160 psi) differential,Input Torque 11 bar (160 psi)
differential,Case Flow
Input Torque and Case Flow Versus Speed @ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
Inpu
t Tor
que
- Nm
(in.
lb.)
Case
Flo
w (l
/min
(USg
pm)
2 (0.53)
4 (1.06)
2 (18)
3 (27)
1 (9) 5 (1.32)
1 (0.26)
3 (0.79)
00
40 (354)
00 500 1000 1500 2000 2500
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
280 bar (4000 psi)Input Torque
150 bar (2200 psi)Input Torque
280 bar (4000 psi), Case Flow
150 bar (2200 psi)Case Flow
10 (88)
20 (177)
30 (265)
50 (442)
5 (45)
15 (135)
25 (221)
35 (310)
45 (398)
Input Torque and Case Flow Versus Speed @ 93°C (200°F), cut-off and 1.0 bar absolute
(0 psi gauge) inlet
3 (0.8)6 (1.6)9 (2.4)
23EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
Input Torque,Cut off
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
Input Torque,Cut off
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM020
6264
60
58
56
54
52
50
48
46
44
42
40
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
1500 r/minMax. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
1000 r/minMin. Flow
Sound pressure dataequivalent to NFPA
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
62
64
60
58
56
54
52
50
48
46
44
42
400 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)Outlet Pressure – bar (psi)
1800 r/minMax. Flow
1800 r/minMin. Flow
1200 r/minMin. Flow
1200 r/minMax. Flow
6264
60
58
56
54
52
50
48
46
44
42
40
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
1500 r/minMax. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
1000 r/minMin. Flow
Sound pressure dataequivalent to NFPA
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
62
64
60
58
56
54
52
50
48
46
44
42
400 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)Outlet Pressure – bar (psi)
1800 r/minMax. Flow
1800 r/minMin. Flow
1200 r/minMin. Flow
1200 r/minMax. Flow
24 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM020
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
Input Torque,Cut off
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
Input Torque,Cut off
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
25EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.3 (0.07)
0.5 (0.13)
0.8 (0.20)
1.0 (0.26)
1.3 (0.33)
1.5 (0.40)
1.8 (0.46)
2.0 (0.53)
2.3 (0.59)
2.5 (0.66)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.3 (0.07)
0.5 (0.13)
0.8 (0.20)
1.0 (0.26)
1.3 (0.33)
1.5 (0.40)
1.8 (0.46)
2.0 (0.53)
2.3 (0.59)
2.5 (0.66)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM020
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
Effic
ienc
y –
%
Effic
ienc
y –
%
Inpu
t Pow
er –
kW
(hp)
Inpu
t tor
que
– N
m (i
n.lb
.)
Inpu
t tor
que
– N
m (i
n.lb
.)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
10 (3)
20 (5)
30 (8)
40 (11)
50 (13)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
Volumetric Efficiency
Overall Efficiency
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
010 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
90 (796)
100 (885)
110 (973)
120 (1062)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Input Power,Full Stroke
Input Torque,Full Stroke
Delivery (effective flow)
26 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM020
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77 2800 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar (2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
600 r/minmax. flow
2800 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77 2800 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar (2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
600 r/minmax. flow
2800 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BATypical Noise Levels at 2800 & 600 r/min with Petroleum Oil (10W)
at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
41
47
56
62
68
74
44
53
59
65
71
50
77 2800 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
150 bar (2200 psi)
230 bar (3300 psi)
210 bar (3000 psi)
50 bar (700 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
20 (5.3)
30 (7.9)
40 (10.6)
50 (13.2)
55 (14.5)
500 1000 1500 2000 2500
15 (4.0)
25 (6.6)
35 (9.2)
45 (11.9)
60 (15.9)
10 (2.6)
5 (1.3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
600 r/minmax. flow
2800 r/minmin. flow
27EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM020
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (l
b.in
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (l
b.in
.)
.8 (7)
1.2 (11)1.4 (12)1.6 (14)1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)2.0 (.53)1.0 (.26)0
3000
2 (18)2.2 (19)
Case Flow l/min
(USgpm)
5.0 (1.32)4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)2.6 (23)2.8 (25)3.0 (27)3.2 (28)
20 bar (290 psi) diff. Input Torque
11 bar (160 psi) diff. Input Torque
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Inpu
t Tor
que
– N
m (l
b.in
.)
30 (265)
Speed (r/min)
9 (2.4)
CaseFlow l/min (USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
210 bar (3000 psi) Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (l
b.in
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (l
b.in
.)
.8 (7)
1.2 (11)1.4 (12)1.6 (14)1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)2.0 (.53)1.0 (.26)0
3000
2 (18)2.2 (19)
Case Flow l/min
(USgpm)
5.0 (1.32)4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)2.6 (23)2.8 (25)3.0 (27)3.2 (28)
20 bar (290 psi) diff. Input Torque
11 bar (160 psi) diff. Input Torque
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Inpu
t Tor
que
– N
m (l
b.in
.)
30 (265)
Speed (r/min)
9 (2.4)
CaseFlow l/min (USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
210 bar (3000 psi) Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (l
b.in
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (l
b.in
.)
.8 (7)
1.2 (11)1.4 (12)1.6 (14)1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)2.0 (.53)1.0 (.26)0
3000
2 (18)2.2 (19)
Case Flow l/min
(USgpm)
5.0 (1.32)4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)2.6 (23)2.8 (25)3.0 (27)3.2 (28)
20 bar (290 psi) diff. Input Torque
11 bar (160 psi) diff. Input Torque
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Inpu
t Tor
que
– N
m (l
b.in
.)
30 (265)
Speed (r/min)
9 (2.4)
CaseFlow l/min (USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
210 bar (3000 psi) Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (l
b.in
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (88)
20 (177)
30 (265)
40 (354)
50 (442)
60 (531)
70 (619)
80 (708)
100 (885)
110 (973)
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
90 (796)
50 bar (725 psi)
100 bar (1500 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
2 (3)
4 (5)
6 (8)
8 (11)
10 (13)
12 (16)
14 (19)
16 (21)
18 (24)
20 (27)
22 (30)
24 (32)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (l
b.in
.)
.8 (7)
1.2 (11)1.4 (12)1.6 (14)1.8 (16)
500 1000 1500 2000 2500
.4 (4)
3.0 (.79)2.0 (.53)1.0 (.26)0
3000
2 (18)2.2 (19)
Case Flow l/min
(USgpm)
5.0 (1.32)4.0 (1.06)
.2 (2)
.6 (5)
1 (9)
2.4 (21)2.6 (23)2.8 (25)3.0 (27)3.2 (28)
20 bar (290 psi) diff. Input Torque
11 bar (160 psi) diff. Input Torque
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
6 (53)
12 (106)
18 (159)
24 (212)
500 1000 1500 2000 2500 3000
3 (27)
9 (80)
15 (133)
21 (186)
27 (239)
Inpu
t Tor
que
– N
m (l
b.in
.)
30 (265)
Speed (r/min)
9 (2.4)
CaseFlow l/min (USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
210 bar (3000 psi) Input Torque
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
28 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
50 (67)
40 (54)
0
Input Torque,Full Stroke
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Inpu
t tor
que
– N
m (i
n.lb
.)
Effic
ienc
y –
%
Deliv
ery
– l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
250(3600)
30 (40)
20 (27)
10 (13)
Input Power, Full Stroke
Input Torque,Cut-off
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
50 (67)
40 (54)
0
Input Torque,Full Stroke
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Inpu
t tor
que
– N
m (i
n.lb
.)
Effic
ienc
y –
%
Deliv
ery
– l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
250(3600)
30 (40)
20 (27)
10 (13)
Input Power, Full Stroke
Input Torque,Cut-off
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM045
72
70
68
66
64
62
60
56
54
52
72
70
68
66
64
62
58
60
56
54
52
50
480 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
Sound pressure data equivalent to NFPA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow1000 r/minMax. Flow
58
72
70
68
66
64
62
60
56
54
52
72
70
68
66
64
62
58
60
56
54
52
50
480 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BAN
oise
Lev
el –
dBA
Sound pressure data equivalent to NFPA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow1000 r/minMax. Flow
58
29EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM045
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
30 (40)
20 (27)
10 (13)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0 Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
30 (40)
20 (27)
10 (13)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
40 (54)
0
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Inpu
t tor
que
– N
m (i
n.lb
.)
Effic
ienc
y –
%
Deliv
ery
– l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
250(3600)
30 (40)
20 (27)
10 (13)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure – bar (psi)
102 (27)
76 (20)
49 (13)
27 (7)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
40 (54)
0
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Inpu
t tor
que
– N
m (i
n.lb
.)
Effic
ienc
y –
%
Del
iver
y –
l/m
in (U
Sgpm
)In
put P
ower
– k
W (h
p)
250(3600)
30 (40)
20 (27)
10 (13)
30 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM045
2,0 (0.53)
1,8 (0.47)
1,6 (0.42)
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.10)
0,2 (0.05)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
6 (1.59)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
2,0 (0.53)
1,8 (0.47)
1,6 (0.42)
1,4 (0.37)
1,2 (0.32)
1,0 (0.26)
0,8 (0.21)
0,6 (0.16)
0,4 (0.10)
0,2 (0.05)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at 1800 r/min, Full Flow50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
6 (1.59)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric EfficiencyOverall Efficiency
Delivery (effective flow)
Input Torque and Power at 1000 r/min50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
30 (40)
20 (27)
10 (13)
0
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
76 (20)
57 (15)
38 (10)
19 (5)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric EfficiencyOverall Efficiency
Delivery (effective flow)
Input Torque and Power at 1000 r/min50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
240 (2125)
210 (1860)
180 (1595)
150 (1325)
120 (1060)
90 (795)
60 (530)
30 (265)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
30 (40)
20 (27)
10 (13)
0
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
31EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Delivery and Case Flow Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
0,5 (.1)
1,0 (.3)
1,5 (.4)
2,0 (.5)
2,5 (.7)
Speed – r/min
Deliv
ery
– l/m
in (U
Sgpm
)
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi),Case flow10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
03000
225 (1991)
195 (1726)
165 (1460)
135 (1195)
105 (929)
75 (664)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
00 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
210 (1858)
180 (1593)
150 (1327)
120 (1062)
90 (796)
60 (531)
30 (265) 17 bar (250 psi)
100 bar (1500 psi)
Input Torque Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
150 bar (2200 psi)
50 bar (700 psi)
PerformanceHigher speed version (M) PVM045
82
78
74
70
66
62
58
54
50
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
600 r/minMin. Flow
600 r/minMax. Flow
2600 r/minMin. Flow
2600 r/minMax. Flow
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet(Sound pressure data equivalent to NFPA)
0 500 1000 1500 2000 2500 3000
Effic
ienc
y –
%
Speed – r/min
250 bar(3600 psi)
200 bar(2900 psi)
100 bar(1500 psi)
17 bar (250 psi)280 bar
(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
50 bar (700 psi)
82
78
74
70
66
62
58
54
50
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
600 r/minMin. Flow
600 r/minMax. Flow
2600 r/minMin. Flow
2600 r/minMax. Flow
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet(Sound pressure data equivalent to NFPA)
0 500 1000 1500 2000 2500 3000
Effic
ienc
y –
%
Speed – r/min
250 bar(3600 psi)
200 bar(2900 psi)
100 bar(1500 psi)
17 bar (250 psi)280 bar
(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
50 bar (700 psi)
Delivery and Case Flow Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
0,5 (.1)
1,0 (.3)
1,5 (.4)
2,0 (.5)
2,5 (.7)
Speed – r/min
Deliv
ery
– l/m
in (U
Sgpm
)
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi),Case flow10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
03000
225 (1991)
195 (1726)
165 (1460)
135 (1195)
105 (929)
75 (664)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
00 500 1000 1500 2000 2500
25 bar (365 psi)
250 bar (3600 psi)
200 bar (2900 psi)
280 bar (4000 psi)
3000
210 (1858)
180 (1593)
150 (1327)
120 (1062)
90 (796)
60 (531)
30 (265) 17 bar (250 psi)
100 bar (1500 psi)
Input Torque Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
150 bar (2200 psi)
50 bar (700 psi)
32 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM045
0 500 1000 1500 2000 2500 3000
Inp
ut
Pow
er @
Fu
ll Fl
ow
– k
W (
hp
)
Speed – r/min
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
Pres
sure
– b
ar (
psi
)
56 (75)
52 (70)
48 (64)
44 (59)40 (54)
36 (48)
32 (43)28 (38)
24 (32)20 (27)
16 (21)
12 (16)8 (11)
4 (5)
0
Input Power Versus Speed 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
6 (1 .6)5 (1 .3) 4 (1 .1) 3 (0 .8) 2 (0 .5)1 (0 .3)
0
Cas
e Fl
ow
– l/
min
(U
Sg
pm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
1.Case Flow at 2600 r/min, Full Flow 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
42 (11 .1)38 (10 .0)34 (9 .0)30 (7 .9)26 (6 .9)22 (5 .8)18 (4 .8)14 (3 .7)10 (2 .6)
Cas
e Fl
ow
– l/
min
(U
Sg
pm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Case Flow at Cutoff at 2600 r/min 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
50 (700)
25 (365)17 (250)
0 500 1000 1500 2000 2500 3000
Inp
ut
Pow
er @
Fu
ll Fl
ow
– k
W (
hp
)
Speed – r/min
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
Pres
sure
– b
ar (
psi
)
56 (75)
52 (70)
48 (64)
44 (59)40 (54)
36 (48)
32 (43)28 (38)
24 (32)20 (27)
16 (21)
12 (16)8 (11)
4 (5)
0
Input Power Versus Speed 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
6 (1 .6)5 (1 .3) 4 (1 .1) 3 (0 .8) 2 (0 .5)1 (0 .3)
0
Cas
e Fl
ow
– l/
min
(U
Sg
pm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
1.Case Flow at 2600 r/min, Full Flow 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
42 (11 .1)38 (10 .0)34 (9 .0)30 (7 .9)26 (6 .9)22 (5 .8)18 (4 .8)14 (3 .7)10 (2 .6)
Cas
e Fl
ow
– l/
min
(U
Sg
pm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Case Flow at Cutoff at 2600 r/min 93°C (200°F), 1 .0 bar absolute (0 psi gauge) Inlet
50 (700)
25 (365)17 (250)
33EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque, Cut-off
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque, Cut-off
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM050
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
44
48
52
56
60
64
68
72
1800 r/minmin. flow 1200 r/min
min. flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
44
48
52
56
60
64
68
72
1500 r/minmin. flow
1000 r/minmin. flow
1000 r/min
max. flow
1500 r/minmax. flow
1200 r/minmax. flow
1800 r/minmax. flow
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
44
48
52
56
60
64
68
72
1800 r/minmin. flow 1200 r/min
min. flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
44
48
52
56
60
64
68
72
1500 r/minmin. flow
1000 r/minmin. flow
1000 r/min
max. flow
1500 r/minmax. flow
1200 r/minmax. flow
1800 r/minmax. flow
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
34 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM050
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque, Cut-off
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque, Cut-off
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n-lb
)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Deliv
ery
– l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Deliv
ery
– l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
35EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.1 (0.03)
0.2 (0.05)
0.3 (0.08)
0.4 (0.11)
0.5 (0.13)
0.6 (0.16)
0.7 (0.18)
0.8 (0.21)
0.9 (0.24)
1.0 (0.26)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.1 (0.03)
0.2 (0.05)
0.3 (0.08)
0.4 (0.11)
0.5 (0.13)
0.6 (0.16)
0.7 (0.18)
0.8 (0.21)
0.9 (0.24)
1.0 (0.26)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM050
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Deliv
ery
– l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Delivery and Efficiency at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Deliv
ery
– l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
010 (13)
20 (27)
30 (40)40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Power,Full Stroke
Input Torque,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
20 (177)
40 (354)
60 (531)
80 (708)
100 (885)
120 (1062)
140 (1239)
160 (1416)
180 (1593)
200 (1770)
220 (1947)
240 (2124)
Input Torque,Full Stroke
Input Power,Full Stroke
36 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM050
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F) and
1.0 bar absolute (0 psi gauge) inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/minmax. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar (2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)140 (37)
20 (5)10 (3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)1 (0.26)0
3000
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
50 bar (725 psi) Delivery
2600 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F) and
1.0 bar absolute (0 psi gauge) inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/minmax. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar (2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)140 (37)
20 (5)10 (3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)1 (0.26)0
3000
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
50 bar (725 psi) Delivery
2600 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2600 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F) and
1.0 bar absolute (0 psi gauge) inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
64
68
74
78
82
86
66
72
76
80
84
70
88
2600 r/minmax. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed (r/min)
50
60
75
85
95
55
70
80
90
65
100
3000
100 bar (1500 psi)
200 bar (2900 psi)
230 bar (3300 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
130 (34)140 (37)
20 (5)10 (3)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
3 (0.79)
5 (1.32)
2 (0.53)1 (0.26)0
3000
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
210 bar (3000 psi) Delivery
50 bar (725 psi) Delivery
2600 r/minmin. flow
37EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM050
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar (3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
03000
7 (62)
8 (71)
20 bar (300 psi) diff. Input Torque
20 bar (300 psi) diff. Case Flow
11 bar (160 psi) diff.Case Flow
11 bar (160 psi) diff.Input Torque
Case Flow l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
Case Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar (3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
03000
7 (62)
8 (71)
20 bar (300 psi) diff. Input Torque
20 bar (300 psi) diff. Case Flow
11 bar (160 psi) diff.Case Flow
11 bar (160 psi) diff.Input Torque
Case Flow l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
Case Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar (3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
03000
7 (62)
8 (71)
20 bar (300 psi) diff. Input Torque
20 bar (300 psi) diff. Case Flow
11 bar (160 psi) diff.Case Flow
11 bar (160 psi) diff.Input Torque
Case Flow l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
Case Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (221)
50 (442)
75 (664)
100 (885)
125 (1106)
150 (1327)
175 (1549)
200 (1770)
250 (2212)
275 (2434)
300 (2655)
3000
210 bar (3000 psi)
200 bar (2900 psi)
225 (1991)
17 bar (250 psi)
100 bar (1500 psi)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
5 (7)
10 (13)
15 (20)
20 (27)
25 (34)
30 (40)
35 (47)
40 (54)
45 (60)
50 (67)
55 (74)
60 (80)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)200 bar (2900 psi)
100 bar (1500 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at93°C (200°F), Load Sense Standby and 1.0 bar
absolute (0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3.0 (.79)
2.0 (.53)
1.0 (.26)
03000
7 (62)
8 (71)
20 bar (300 psi) diff. Input Torque
20 bar (300 psi) diff. Case Flow
11 bar (160 psi) diff.Case Flow
11 bar (160 psi) diff.Input Torque
Case Flow l/min
(USgpm)
5.0 (1.32)
4.0 (1.06)
0
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-off and
1.0 bar absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
5 (44)
15 (133)
25 (221)
35 (310)
45 (398)
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
55 (487)
210 bar (3000 psi) Input Torque
Speed (r/min)
12 (3.2)
9 (2.4)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Case Flow
Case Flow l/min
(USgpm)
6 (1.6)
3 (0.8)
150 bar (2200 psi) Input Torque
38 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Inpu
t Tor
que
– N
m (i
n.lb
.)
Outlet Pressure – bar (psi)
130 (34)
104 (28)
78 (21)
52 (14)
26 (7)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM057
70
66
62
58
54
74
70
66
62
58
54
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure dataequivalent to NFPA)
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
(1500) (2200) (2900) (3600)
Noi
se L
evel
– d
BA
0 50(700)
100 150 200 250 300(4400)
Outlet Pressure – bar (psi)
1000 r/minMin. Flow
1000 r/minMax. Flow
1500 r/minMin. Flow
1500 r/minMax. Flow
70
66
62
58
54
74
70
66
62
58
54
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure dataequivalent to NFPA)
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
(1500) (2200) (2900) (3600)
Noi
se L
evel
– d
BA
0 50(700)
100 150 200 250 300(4400)
Outlet Pressure – bar (psi)
1000 r/minMin. Flow
1000 r/minMax. Flow
1500 r/minMin. Flow
1500 r/minMax. Flow
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Inpu
t Tor
que
– N
m (i
n.lb
.)
Outlet Pressure – bar (psi)
130 (34)
104 (28)
78 (21)
52 (14)
26 (7)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
39EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)In
put T
orqu
e –
Nm
(in.
lb.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
40 (54)
30 (40)
20 (27)
10 (13)
0
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)In
put T
orqu
e –
Nm
(in.
lb.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
40 (54)
30 (40)
20 (27)
10 (13)
0
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM057
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
60 (80)
50 (67)
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
40 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
1,1 (0.29)
1,0 (0.26)
0,9 (0.24)
0,8 (0.21)
0,7 (0.18)
0,6 (0.16)
0,5 (0.13)
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
5 (1.32)
4 (1.06)
3 (0.79)
2 (0.53)
1 (0.26)
0
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
1,1 (0.29)
1,0 (0.26)
0,9 (0.24)
0,8 (0.21)
0,7 (0.18)
0,6 (0.16)
0,5 (0.13)
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM057
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
80 (21)
60 (16)
40 (11)
20 (5)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
40 (54)
30 (40)
20 (27)
10 (13)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
80 (21)
60 (16)
40 (11)
20 (5)
0 Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
330 (2921)
300 (2655)
270 (2390)
240 (2124)
210 (1859)
180 (1593)
150 (1328)
120 (1062)
90 (797)
60 (531)
30 (266)
0
40 (54)
30 (40)
20 (27)
10 (13)
0
41EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM057
82
78
74
70
66
62
58
54
50
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
600 r/minMin. Flow
600 r/minMax. Flow
2500 r/minMin. Flow
2500 r/minMax. Flow
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),1.0 bar absolute (0 psi gauge) Inlet
(Sound pressuredata equivalent to NFPA)
0 500 1000 1500 2000 2500
Effic
ienc
y –
%
Speed – r/min
250 bar (3600 psi)
200 bar (2900psi)
50 bar (700 psi)
280 bar (4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
65
100 bar(1500 psi)
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
82
78
74
70
66
62
58
54
50
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
600 r/minMin. Flow
600 r/minMax. Flow
2500 r/minMin. Flow
2500 r/minMax. Flow
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),1.0 bar absolute (0 psi gauge) Inlet
(Sound pressuredata equivalent to NFPA)
0 500 1000 1500 2000 2500
Effic
ienc
y –
%
Speed – r/min
250 bar (3600 psi)
200 bar (2900psi)
50 bar (700 psi)
280 bar (4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
65
100 bar(1500 psi)
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet 280 (2478)
240 (2124)
200 (1770)
160 (1416)
80 (708)
40 (354)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
00 500 1000 1500 2000 2500 3000
300 (2655)
260 (1858)
220 (1947)
180 (1593)
120 (1062)100 (885)
60 (531)
20 (177)
140 (1239)
320 (2832)
Input Torque Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
1,0 (0.3)2,0 (0.5)3,0 (0.8)
Speed – r/min
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
140 (37)130 (34)
150 (40)
4,0 (1.1)5,0 (1.3)6,0 (1.6)
50 bar (700 psi),Case flow
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
100 bar (1500 psi)
250 bar (3600 psi)
150 bar(2200 psi)
17 bar (250 psi)
200 bar (2900 psi)
320 bar (4600 psi)
280 bar (4000 psi)
50 bar (700 psi)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
80 (708)
40 (354)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
00 500 1000 1500 2000 2500 3000
300 (2655)
260 (1858)
220 (1947)
180 (1593)
120 (1062)100 (885)
60 (531)
20 (177)
140 (1239)
320 (2832)
Input Torque Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
1,0 (0.3)2,0 (0.5)3,0 (0.8)
Speed – r/min
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
10 (3)
30 (8)
50 (13)
70 (18)
90 (24)
110 (29)
0
140 (37)130 (34)
150 (40)
4,0 (1.1)5,0 (1.3)6,0 (1.6)
50 bar (700 psi),Case flow
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
100 bar (1500 psi)
250 bar (3600 psi)
150 bar(2200 psi)
17 bar (250 psi)
200 bar (2900 psi)
320 bar (4600 psi)
280 bar (4000 psi)
50 bar (700 psi)
42 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM057
0 500 1000 1500 2000 2500
Inpu
t Pow
er @
Ful
l Flo
w –
kW
(hp)
Speed – r/min
250 (3600)
200 (2900)
150 (2200)
100 (1500)
50 (700)
17 (250)
280 (4000)
320 (4600)
Pres
sure
– b
ar (p
si)
60 (80)
48 (64)
36 (48)
24 (32)
12 (16)
66 (89)
72 (97)
78 (105)
6 (8)
18 (24)
30 (40)
42 (56)
54 (72)
0
Input Power Versus Speed 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
20 bar (300 psi) differential, Input Torque11 bar (160 psi)
differential,Input Torque
20 bar (300 psi) differential, Case Flow0
0 500 1000 1500 2000 2500Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w –
l/m
in (U
Sgpm
)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
4.0 (1.06)
6 (53)
4 (35)
2 (18)
0
1 (9)
3 (27)
5 (44)
Input Torque and Case Flow Versus Speed @ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
0 500 1000 1500 2000 25002 (0.5)4 (1.1)6 (1.6)8 (2.1)10 (2.6)
Case
Flo
w –
l/m
in (U
Sgpm
)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
280 bar (4000 psi)Input Torque
150 bar (2200 psi), Input Torque
280 bar (4000 psi)Case Flow
150 bar (2200 psi), Case Flow
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
Input Torque and Case Flow Versus Speed@ 93°C (200°F), cut-off and 1.0 bar absolute (0 psi gauge) inlet
11 bar (160 psi) differential, Case Flow
43EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM063
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50
55
60
65
70
75
1200 r/minmax. flow1800 r/min
min. flow
1200 r/minmin. flow
1800 r/minmax. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50
55
65
70
75
1500 r/minmax. flow
1000 r/minmin. flow
Typical Noise Levels at 1500 and 1000 r/min. withPetroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
60
1000 r/minmax. flow
1500 r/minmin. flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50
55
60
65
70
75
1200 r/minmax. flow1800 r/min
min. flow
1200 r/minmin. flow
1800 r/minmax. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
50
55
65
70
75
1500 r/minmax. flow
1000 r/minmin. flow
Typical Noise Levels at 1500 and 1000 r/min. withPetroleum Oil (10W) at 50°C (120°F) and 1.0 bar
absolute (0 psi gauge) Inlet
60
1000 r/minmax. flow
1500 r/minmin. flow
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque, Cut-off
Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque, Cut-off
Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Delivery (effective flow)
44 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM063
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque, Cut-off
Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
120 (32)
Volumetric Efficiency
Delivery (effective flow)
Overall Efficiency
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
Input Torque, Cut-off
Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
-l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Overall Efficiency
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
-l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Overall Efficiency
Delivery (effective flow)
45EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
- (U
Sgpm
)
Outlet Pressure - bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
- (U
Sgpm
)
Outlet Pressure - bar (psi)
0
1 (0.26)
2 (0.53)
3 (0.79)
4 (1.06)
5 (1.32)
6 (1.59)
7 (1.85)
8 (2.11)
9 (2.38)
10 (2.64)
11 (2.91)
12 (3.17)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM063
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
-l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Overall Efficiency
Delivery (effective flow)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
-l/m
in (U
Sgpm
)
0
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0
10
20
30
40
50
60
70
80
90
100Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
00
10
20
30
40
50
60
70
80
90
100
20 (5)
40 (11)
60 (16)
80 (21)
100 (26)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
0
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)Input Torque,Full Stroke
Input Power,Full Stroke
240 (2124)
270 (2390)
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
00
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
30 (226)
60 (531)
90 (1327)
120 (1062)
150 (1328)
180 (1593)
210 (1859)
240 (2124)
270 (2390)
Input Torque,Full Stroke
Input Power,Full Stroke
Overall Efficiency
Delivery (effective flow)
46 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM063
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
50
55
60
65
70
75
802500 r/minmax. flow
2500 r/minmin. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
85
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar (1450 psi)
150 bar (2200 psi)
210 bar (3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
50
55
60
65
70
75
802500 r/minmax. flow
2500 r/minmin. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
85
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar (1450 psi)
150 bar (2200 psi)
210 bar (3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2500 & 600 r/min with Petroleum Oil (10W)at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
50
55
60
65
70
75
802500 r/minmax. flow
2500 r/minmin. flow
600 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
85
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
230 bar (3300 psi)
100 bar (1450 psi)
150 bar (2200 psi)
210 bar (3000 psi)
60
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
Case
Flo
w –
l/m
in (U
Sgpm
)
4 (1.06)
2 (0.53)
0
3000
50 bar (725 psi) Delivery
210 bar (3000 psi) Case Flow
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
47EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM063
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case
Flo
w –
l/m
in (U
Sgpm
)
6.0 (1.59)
03000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque 8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
20 bar (300 psi) diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case
Flo
w –
l/m
in (U
Sgpm
)
6.0 (1.59)
03000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque 8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
20 bar (300 psi) diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case
Flo
w –
l/m
in (U
Sgpm
)
6.0 (1.59)
03000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque 8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
20 bar (300 psi) diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case
Flo
w –
l/m
in (U
Sgpm
)150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
230 bar (3300 psi)210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
60 (80)
70 (94)
80 (107)
100 (134)
50 bar (725 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and
1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
Case
Flo
w –
l/m
in (U
Sgpm
)
6.0 (1.59)
03000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque 8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
20 bar (300 psi) diff. Case Flow
2.0 (.53)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar
absolute (0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
210 bar (3000 psi) Input Torque
150 bar (2200 psi) Input Torque
Speed (r/min)
2.0 (.53)
Case
Flo
w –
l/m
in (U
Sgpm
)150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
10.0 (2.64)
12.0 (3.17)
14.0 (3.70)
16.0 (4.23)
18.0 (4.76)
20.0 (5.28)
210 bar (3000 psi) Case Flow
48 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
80 (107)
60 (80)
40 (54)
20 (27)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
150 (40)
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
80 (107)
60 (80)
40 (54)
20 (27)
0 Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
150 (40)
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM074
72
70
68
66
64
62
60
58
56
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
76
74
72
70
68
66
64
62
60
58
Noi
se L
evel
– d
BA
Sound pressure dataequivalent to NFPA.
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
72
70
68
66
64
62
60
58
56
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
76
74
72
70
68
66
64
62
60
58
Noi
se L
evel
– d
BA
Sound pressure dataequivalent to NFPA.
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
49EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM074
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric EfficiencyOverall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
125 (33)
100 (26)
75 (20)
50 (13)
25 (7)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric EfficiencyOverall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
50 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
12 (3.17)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Case
Flo
w -
l/m
in (U
Sgpm
)Ca
se F
low
- l/
min
(USg
pm)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
11 (2.91)
10 (2.64)
9 (2.38)
8 (2.11)
7 (1.85)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
12 (3.17)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min 50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
Case
Flo
w -
l/min
(USg
pm)
Case
Flo
w -
l/min
(USg
pm)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
11 (2.91)
10 (2.64)
9 (2.38)
8 (2.11)
7 (1.85)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM074
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
75 (20)
50 (13)
25 (7)
0 Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
400 (3540)
360 (3186)
320 (2832)
280 (2478)
240 (2124)
200 (1770)
160 (1416)
120 (1062)
80 (708)
40 (354)
0
80 (107)
60 (80)
40 (54)
20 (27)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100 (26)
75 (20)
50 (13)
25 (7)
0 Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
51EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
160 (42)
120 (32)
80 (21)
40 (11)
00 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi), Case flow
50 bar (700 psi), Case flow20 (5)
60 (16)
100 (26)
140 (37)
180 (48)
0 Case
Flo
w –
l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)In
put T
orqu
e –
Nm
(in.
lb.)
Delivery and Case Flow Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi) gauge Inlet
350 (3097)300 (2655)250 (2212)200 (1770)150 (1327)
100 (885)50 (442)
Speed – r/min
00 500 1000 1500 2000 2500
50 bar (700 psi)17 bar (250 psi)
400 (3540)
Input Torque Versus Speed@ 93°C (200°F), full flow and 1.0 bar absolute (0 psi gauge) inlet
320 bar (4600 psi)
250 bar (3600 psi)
150 bar (2200 psi)200 bar (2900 psi)
280 bar (4000 psi)
100 bar (1500 psi)
Pres
sure
– b
ar (p
si)
70 (94)60 (80)50 (67)40 (54)30 (40)20 (27)10 (13)
100 (134)90 (121)80 (107)
0 500 1000 1500 2000 2500
Inpu
t Pow
er @
Ful
l Flo
w –
kW
(hp)
Speed – r/min
Input Power Versus Speed 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
280 (4000)
250 (3600)
200 (2900)
150 (2200)
100 (1500)
50 (700)
17 (250)
320 (4600)
Pres
sure
– b
ar (p
si)
0
PerformanceHigher speed version (M) PVM074
0 500 1000 1500 2000 2500
Effic
ienc
y –
%
Speed – r/min
250 bar(3600 psi)
200 bar(2900psi)
100 bar(1500 psi)
50 bar (700 psi)
320 bar (4600 psi)
280 bar(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
65
60
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
84
80
76
72
68
64
60
56
52
Noi
se L
evel
– d
BA
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
2400 r/min Min. Flow
2400 r/min Max. Flow
600 r/minMax. Flow
600 r/min Min. Flow
0 500 1000 1500 2000 2500
Effic
ienc
y –
%
Speed – r/min
250 bar(3600 psi)
200 bar(2900psi)
100 bar(1500 psi)
50 bar (700 psi)
320 bar (4600 psi)
280 bar(4000 psi)
150 bar(2200 psi)
95
90
85
80
75
70
65
60
Overall Efficiency Versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) Inlet
84
80
76
72
68
64
60
56
52
Noi
se L
evel
– d
BA
Typical Noise Levels Petroleum Oil (10W) at 93°C (200°F),
1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
(Sound pressure data equivalent to NFPA)
2400 r/min Min. Flow
2400 r/min Max. Flow
600 r/minMax. Flow
600 r/min Min. Flow
52 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM074
20 bar (300 psi) differential,Input Torque
11 bar (160 psi) differentialCase Flow
20 bar (300 psi) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w –
l/m
in (U
Sgpm
)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
0
4.0 (1.06)
6 (53)
4 (35)
2 (18)
00 500 1000 1500 2000 2500
1 (9)
3 (27)
5 (44)
7 (62)
11 bar (160) differentialInput Torque
Input Torque and Case Flow Versus Speed@ 93°C (200°F), load sense standby and
1.0 bar absolute (0 psi gauge) inlet
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
00 500 1000 1500 2000 2500
0
10 (2.6)
20 (5.3)
30 (7.9)
Case
Flo
w –
l/m
in (U
Sgpm
)
Speed – r/min
280 bar (4000 psi),Input Torque
150 bar (2200 psi),Input Torque
280 bar (4000 psi), Case Flow
Inpu
t Tor
que
– N
m (i
n.lb
.)
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential,Input Torque
11 bar (160 psi) differentialCase Flow
20 bar (300 psi) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w –
l/m
in (U
Sgpm
)
8.0 (2.11)
6.0 (1.58)
2.0 (0.53)
0
4.0 (1.06)
6 (53)
4 (35)
2 (18)
00 500 1000 1500 2000 2500
1 (9)
3 (27)
5 (44)
7 (62)
11 bar (160) differentialInput Torque
Input Torque and Case Flow Versus Speed@ 93°C (200°F), load sense standby and
1.0 bar absolute (0 psi gauge) inlet
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)
00 500 1000 1500 2000 2500
0
10 (2.6)
20 (5.3)
30 (7.9)
Case
Flo
w –
l/m
in (U
Sgpm
)
Speed – r/min
280 bar (4000 psi),Input Torque
150 bar (2200 psi),Input Torque
280 bar (4000 psi), Case Flow
Inpu
t Tor
que
– N
m (i
n.lb
.)
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
53EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM081
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
58
60
64
66
68
1800 r/minmin. flow
70
72
74
1200 r/minmax. flow
62
1800 r/minmax. flow
Typical Noise Levels at 1500 and 1000 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
56
58
60
62
64
66
68
70
72
1500 r/minmax. flow
1500 r/minmin. flow
1000 r/minmax. flow
1200 r/minmin. flow
1000 r/minmin. flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
58
60
64
66
68
1800 r/minmin. flow
70
72
74
1200 r/minmax. flow
62
1800 r/minmax. flow
Typical Noise Levels at 1500 and 1000 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
56
58
60
62
64
66
68
70
72
1500 r/minmax. flow
1500 r/minmin. flow
1000 r/minmax. flow
1200 r/minmin. flow
1000 r/minmin. flow
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
54 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM081
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
Outlet Pressure – bar (psi)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
55EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
- (U
Sgpm
)
Outlet Pressure - bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
- (U
Sgpm
)
Outlet Pressure - bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM081
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
0
25 (7)
50 (13)
75 (20)
100 (26)
125 (33)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Inpu
t Pow
er –
kW
(hp)
Volumetric Efficiency Volumetric Efficiency
56 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2400 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782400 r/minmin. flow
2400 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)100 bar (1450 psi)150 bar
(2200 psi)
200 bar (2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speedat 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
03000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725 psi) Delivery
600 r/minmax. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2400 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782400 r/minmin. flow
2400 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)100 bar (1450 psi)150 bar
(2200 psi)
200 bar (2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speedat 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
03000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725 psi) Delivery
600 r/minmax. flow
PerformanceHigher speed version (M) PVM081
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2400 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782400 r/minmin. flow
2400 r/minmax. flow
600 r/minmin. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speedat 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)100 bar (1450 psi)150 bar
(2200 psi)
200 bar (2900 psi)
60
230 bar (3300 psi)
Delivery and Case Flow versus Speedat 93°C (200°F), Full Flow 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)
03000
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
50 bar (725 psi) Delivery
600 r/minmax. flow
57EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM081
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi) diff. Case Flow
9 (80)
2.0 (0.53)
Case Flow l/min (USgpm)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
Speed (r/min)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Input Torque150 bar (2200 psi) Input Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi) diff. Case Flow
9 (80)
2.0 (0.53)
Case Flow l/min (USgpm)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
Speed (r/min)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Input Torque150 bar (2200 psi) Input Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi) diff. Case Flow
9 (80)
2.0 (0.53)
Case Flow l/min (USgpm)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
Speed (r/min)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Input Torque150 bar (2200 psi) Input Torque
2.0 (.53)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
0 1000500 20001500Speed (r/min)
25000
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
200 bar (2900 psi)
230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)In
put P
ower
– k
W (h
p)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9)
3000
7 (62)
8 (71)
11 bar (160 psi) diff.Input Torque
8.0 (2.11)
10.0 (2.64)
20 bar (300 psi) diff. Case Flow
9 (80)
2.0 (0.53)
Case Flow l/min (USgpm)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Case Flow
6.0 (1.59)
4.0 (1.06)
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)
20 (177)
30 (265)
40 (354)
500 1000 1500 2000 2500 3000
Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)
60 (531)
Speed (r/min)
Case
Flo
w –
l/m
in (U
Sgpm
)
150 bar (2200 psi) Case Flow
70 (619)
80 (708)
4.0 (1.06)
6.0 (1.59)
8.0 (2.11)
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Input Torque150 bar (2200 psi) Input Torque
2.0 (.53)
58 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
72
70
68
66
64
62
60
58
56
54
52
78
76
74
72
70
68
66
64
62
60
58
560 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BA
Sound pressure dataequivalent to NFPA)
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
72
70
68
66
64
62
60
58
56
54
52
78
76
74
72
70
68
66
64
62
60
58
560 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)Outlet Pressure – bar (psi)
Noi
se L
evel
– d
BA
Sound pressure dataequivalent to NFPA)
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1200 r/minMin. Flow
1200 r/minMax. Flow
1800 r/minMin. Flow
1800 r/minMax. Flow
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
Typical Noise Levels at 1500 and 1000 r/min with Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minMax. Flow
1000 r/minMin. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Deliv
ery
-l/m
in (U
Sgpm
)
Inpu
t Tor
que
- Nm
(in.
lb.)
Effic
ienc
y - %
Inpu
t Pow
er -
kW (h
p)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque,Cut-off
Input Torque and Power at 1800 r/min 50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Deliv
ery
-l/m
in (U
Sgpm
)
Inpu
t Tor
que
- Nm
(in.
lb.)
Effic
ienc
y - %
Inpu
t Pow
er -
kW (h
p)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM098
59EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100 (134)
75 (101)
50 (67)
25 (34)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
150 (40)
100 (26)
50 (13)
0
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
100 (134)
75 (101)
50 (67)
25 (34)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
150 (40)
100 (26)
50 (13)
0
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM098
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
200 (53)
150 (40)
100 (26)
50 (13)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
200 (53)
150 (40)
100 (26)
50 (13)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
60 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
5,5 (1.45)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
25 (6.60)
24 (6.34)
23 (6.08)
22 (5.81)
21 (5.55)
20 (5.28)
19 (5.02)
18 (4.76)
17 (4.49)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
Case
Flo
w -
l/m
in (U
Sgpm
)Ca
se F
low
- l/
min
(USg
pm)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
5,5 (1.45)
5,0 (1.32)
4,5 (1.19)
4,0 (1.06)
3,5 (0.92)
3,0 (0.79)
2,5 (0.66)
2,0 (0.53)
1,5 (0.40)
1,0 (0.26)
0,5 (0.13)
0
25 (6.60)
24 (6.34)
23 (6.08)
22 (5.81)
21 (5.55)
20 (5.28)
19 (5.02)
18 (4.76)
17 (4.49)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120° F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
Case
Flo
w -
l/min
(USg
pm)
Case
Flo
w -
l/min
(USg
pm)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM098
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque,Full Stroke
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
100 (134)
75 (101)
50 (67)
25 (34)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
200 (53)
150 (40)
100 (26)
50 (13)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
550 (4867)
500 (4425)
450 (3982)
400 (3540)
350 (3097)
300 (2655)
250 (2212)
200 (1770)
150 (1327)
100 (885)
50 (442)
0
61EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Delivery and Case Flow Versus Speed@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi),Case flow
Deliv
ery
– l/m
in (U
Sgpm
)
0
600 (5310)
540 (4779)
420 (3717)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
480 (4248)
360 (3186)
Inpu
t Tor
que
– N
m (i
n.lb
.)
500 1000 1500 2000 2500 3000
Input Torque Versus Speed@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
PerformanceHigher speed version (M) PVM098
100 bar (1500 psi)150 bar (2200 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)70
75
80
85
90
95
0 500 1000 1500 2000 2500Speed – r/min
Over
all E
ffici
ency
(%)
50 bar (700 psi)
Overall Efficiency Versus Speed@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
064
66
68
70
72
74
76
78
80
82
84
86
Noi
se L
evel
– d
BA
600 r/min Max. flow
600 r/min Min. flow
2000 r/minMax. flow
2000 r/minMin. flow
Sound pressure data equivalent to NFP
Typical Noise Levels at 2000 and 600 r/minwith petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
100 bar (1500 psi)150 bar (2200 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)70
75
80
85
90
95
0 500 1000 1500 2000 2500Speed – r/min
Over
all E
ffici
ency
(%)
50 bar (700 psi)
Overall Efficiency Versus Speed@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
064
66
68
70
72
74
76
78
80
82
84
86
Noi
se L
evel
– d
BA
600 r/min Max. flow
600 r/min Min. flow
2000 r/minMax. flow
2000 r/minMin. flow
Sound pressure data equivalent to NFP
Typical Noise Levels at 2000 and 600 r/minwith petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet Delivery and Case Flow Versus Speed@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
00 500 1000 1500 2000 2500
2 (0.5)
4 (1.1)
6 (1.6)
8 (2.1)
Speed – r/min
Case
Flo
w –
l/m
in (U
Sgpm
)
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi),Case flow
Deliv
ery
– l/m
in (U
Sgpm
)
0
600 (5310)
540 (4779)
420 (3717)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
480 (4248)
360 (3186)
Inpu
t Tor
que
– N
m (i
n.lb
.)
500 1000 1500 2000 2500 3000
Input Torque Versus Speed@ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
Speed – r/min
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
62 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Case Flow at 2200 r/min, Full Flow 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
16 (4.2)
14 (3.7)12 (3.2)10 (2.6)8 (2.1)6 (1.6)4 (1.0)2 (0.5)
0Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
240 (2124)
220 (1947)
200 (1770)
180 (1593)
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)
20 (177)0 500 1000 1500 2000 2500
5 (1.3)10 (2.6)15 (4.0)20 (5.3)25 (6.6)30 (7.9)
Case
Flo
w –
l/m
in (U
Sgpm
)
Inpu
t Tor
que
– N
m (l
b.in
.)
Speed – r/min
280 bar (4000 psi)Input Torque
150 bar (2200 psi) Input Torque
280 bar (4000 psi)Case Flow
150 bar (2200 psi), Case Flow
Input Torque and Case Flow Versus Speed@ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
32 (8.4)
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
Case Flow at 2200 r/min, Minimum Flow935C (2005F), 1.0 bar absolute (0 psi gauge) Inlet
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
PerformanceHigher speed version (M) PVM098
20 bar (300) differentialInput Torque
11 bar (160) differentialInput Torque
11 bar (160) differentialCase Flow
20 bar (300) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w (l
/min
(USg
pm)
7.0 (1.85)
6.5 (1.72)
6.0 (1.59)
5.5 (1.45)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0 500 1000 1500 2000 2500
9.0 (2.38)
8.5 (2.25)
8.0 (2.11)
7.5 (1.98)
1 (9)
3 (27)
5 (44)
7 (62)
9 (80)
11 (77)
Input Torque and Case Flow Versus Speed@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)130 (174)
Inpu
t Pow
er –
KW
(hp)
03000
Input Power Versus Speed@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300) differentialInput Torque
11 bar (160) differentialInput Torque
11 bar (160) differentialCase Flow
20 bar (300) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w (l
/min
(USg
pm)
7.0 (1.85)
6.5 (1.72)
6.0 (1.59)
5.5 (1.45)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
0 500 1000 1500 2000 2500
9.0 (2.38)
8.5 (2.25)
8.0 (2.11)
7.5 (1.98)
1 (9)
3 (27)
5 (44)
7 (62)
9 (80)
11 (77)
Input Torque and Case Flow Versus Speed@ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
60 (80)
70 (94)
80 (107)
90 (121)
100 (134)
110 (148)
120 (161)130 (174)
Inpu
t Pow
er –
KW
(hp)
03000
Input Power Versus Speed@93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
63EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure - bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure - bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM106
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
62
64
68
70
72 1200 r/minmin. flow
74
76
78
1200 r/minmax. flow
80
66
1800 r/minmax. flow
1800 r/minmin. flow
Typical Noise Levels at 1500 and 1000 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
58
60
62
64
66
68
70
72
1000 r/minmin. flow
1500 r/minmin. flow
74
76
1000 r/minmax. flow
1500 r/minmax. flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
62
64
68
70
72 1200 r/minmin. flow
74
76
78
1200 r/minmax. flow
80
66
1800 r/minmax. flow
1800 r/minmin. flow
Typical Noise Levels at 1500 and 1000 r/min. with Petroleum Oil (10W) at 50°C (120°F)
and 1.0 bar absolute (0 psi gauge) Inlet
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)Sound pressure dataequivalent to NFPA.
58
60
62
64
66
68
70
72
1000 r/minmin. flow
1500 r/minmin. flow
74
76
1000 r/minmax. flow
1500 r/minmax. flow
64 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM106
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure - bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y - %
Outlet Pressure - bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (13)
100 (26)
0
10
20
30
40
50
60
70
80
90
100
150 (40)
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
200 (53)
250 (66)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
Overall Efficiency
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure - bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
Input Power,Full Stroke
Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
Input Torque,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
Input Torque,Full Stroke
65EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
Case Flow versus Outlet Pressure at 1800 r/min, Full Flow, 50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0
0.5 (0.13)
1.0 (0.26)
1.5 (0.4)
2.0 (0.53)
2.5 (0.66)
3.0 (0.79)
3.5 (0.92)
4.0 (1.06)
Case Flow versus Outlet Pressure at Cutoff, 1800 r/min,50°C (120°F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Case
Flo
w l/
min
– (U
Sgpm
)
Outlet Pressure – bar (psi)
0
11 (2.91)
12 (3.17)
14 (3.70)
15 (3.96)
17 (4.49)
18 (4.76)
13 (3.43)
16 (4.23)
19 (5.02)
20 (5.28)
21 (5.55)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM106
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
Input Torque,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Deliv
ery
– l/m
in (U
Sgpm
)
00
10
20
30
40
50
60
70
80
90
100
Overall Efficiency
Delivery (effective flow)
Volumetric Efficiency
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)Input Torque,Full Stroke
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
100 (134)
Input Power,Full Stroke
Input Torque,Full Stroke
66 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM106
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2200 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782200 r/minmin. flow
600 r/minmax. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar (1450 psi)150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar (2900 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)0
50 bar (725 psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/minmin. flow
2200 r/minmax. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2200 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782200 r/minmin. flow
600 r/minmax. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar (1450 psi)150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar (2900 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)0
50 bar (725 psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/minmin. flow
2200 r/minmax. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
Typical Noise Levels at 2200 & 600 r/min with Petroleum Oil (10W) at 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
54
58
62
66
70
74
782200 r/minmin. flow
600 r/minmax. flow
Outlet Pressure – bar (psi)
82
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F) and 1.0 bar absolute (0 psi gauge) inlet
0 500 1000 1500 2000 2500
Speed – r/min
50
75
85
95
55
70
80
90
65
100
3000
50 bar (725 psi)
100 bar (1450 psi)150 bar
(2200 psi)
60
230 bar (3300 psi)
200 bar (2900 psi)
210 bar (3000 psi)
Delivery and Case Flow versus Speed at 93°C (200°F),Full Flow 1.0 bar absolute (0 psi gauge) Inlet
0Speed (r/min)
Deliv
ery
– l/m
in (U
Sgpm
)
40 (11)
60 (16)
80 (21)
100 (26)
120 (32)
500 1000 1500 2000 2500
140 (37)
20 (5)
4 (1.06)
2 (0.53)0
50 bar (725 psi) Delivery
50 bar (725 psi) Case Flow
160 (42)
6 (1.59)
8 (2.11)
210 bar (3000 psi) Delivery
200 (53)
180 (48)
Case Flow l/min
(USgpm)
210 bar (3000 psi) Case Flow
240 (63)
220 (58)
10 (2.6)
86
600 r/minmin. flow
2200 r/minmax. flow
67EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM106
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)400 (3540)
450 (3982)
200 bar (2900 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9) 6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)20 bar (300 psi) diff. Case Flow
9 (80)
6.0 (1.59)
Case Flow l/min (USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Input Torque
11 bar (160 psi) diff.Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)20 (177)30 (265)40 (354)
500 1000 1500 2000 2500
(Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi) Case Flow
70 (619)80 (708)
10 (2.6)15 (4.0)
30 (7.9)
150 bar (2200 psi) Input Torque
Case Flow l/min (USgpm)
90 (796)100 (885)110 (973)
120 (1062)130 (1150)140 (1239)
210 bar (3000 psi) Case Flow25 (6.6)
20 (5.3)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)400 (3540)
450 (3982)
200 bar (2900 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9) 6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)20 bar (300 psi) diff. Case Flow
9 (80)
6.0 (1.59)
Case Flow l/min (USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Input Torque
11 bar (160 psi) diff.Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)20 (177)30 (265)40 (354)
500 1000 1500 2000 2500
(Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi) Case Flow
70 (619)80 (708)
10 (2.6)15 (4.0)
30 (7.9)
150 bar (2200 psi) Input Torque
Case Flow l/min (USgpm)
90 (796)100 (885)110 (973)
120 (1062)130 (1150)140 (1239)
210 bar (3000 psi) Case Flow25 (6.6)
20 (5.3)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)400 (3540)
450 (3982)
200 bar (2900 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9) 6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)20 bar (300 psi) diff. Case Flow
9 (80)
6.0 (1.59)
Case Flow l/min (USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Input Torque
11 bar (160 psi) diff.Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)20 (177)30 (265)40 (354)
500 1000 1500 2000 2500
(Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi) Case Flow
70 (619)80 (708)
10 (2.6)15 (4.0)
30 (7.9)
150 bar (2200 psi) Input Torque
Case Flow l/min (USgpm)
90 (796)100 (885)110 (973)
120 (1062)130 (1150)140 (1239)
210 bar (3000 psi) Case Flow25 (6.6)
20 (5.3)
0 1000500 20001500Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
210 bar (3000 psi)
150 bar (2200 psi)
100 bar (1500 psi)
17 bar (250 psi)
50 bar (725 psi)
350 (3097)
230 bar (3300 psi)400 (3540)
450 (3982)
200 bar (2900 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Pow
er –
kW
(hp)
0
10 (13)
20 (27)
30 (40)
40 (54)
50 (67)
90 (121)
Input Power versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
3000
60 (80)
70 (94)
80 (107)
100 (134)
210 bar (3000 psi)230 bar (3300 psi)
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
17 bar (250 psi)
Input Torque and Case Flow versus Speed at 93°C (200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
2 (18)
3 (27)
4 (35)
5 (44)
6 (53)
500 1000 1500 2000 2500
1 (9) 6.5 (1.72)
7.0 (1.85)
7 (62)
8 (71)
7.5 (1.98)
8.0 (2.11)20 bar (300 psi) diff. Case Flow
9 (80)
6.0 (1.59)
Case Flow l/min (USgpm)
12 (106)
10 (88)
11 (97)
8.5 (2.25)
9.0 (2.38)
20 bar (300 psi) diff. Input Torque
11 bar (160 psi) diff.Input Torque
11 bar (160 psi) diff.Case Flow
0
Input Torque and Case Flow versus Speed at 93°C (200°F), Pressure Limit Cut-off and 1.0 bar absolute
(0 psi gauge) Inlet
10 (88)20 (177)30 (265)40 (354)
500 1000 1500 2000 2500
(Inpu
t Tor
que
– N
m (i
n.lb
.)
50 (442)60 (531)
210 bar (3000 psi) Input Torque
Speed (r/min)
5 (1.3)
150 bar (2200 psi) Case Flow
70 (619)80 (708)
10 (2.6)15 (4.0)
30 (7.9)
150 bar (2200 psi) Input Torque
Case Flow l/min (USgpm)
90 (796)100 (885)110 (973)
120 (1062)130 (1150)140 (1239)
210 bar (3000 psi) Case Flow25 (6.6)
20 (5.3)
68 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
140 (188)
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque,Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
140 (188)
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque,Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Input Torque and Power at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM131
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
76
74
72
70
68
66
64
62
60
58
56
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
1500 r/minMax. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
1000 r/minMin. Flow
82
80
78
76
74
72
70
68
66
64
62
60
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
Sound pressure dataequivalent to NFPA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
1800 r/minMax. Flow
1800 r/minMin. Flow
1200 r/minMax. Flow
1200 r/minMin. Flow
Typical Noise Levels at 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
76
74
72
70
68
66
64
62
60
58
56
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
1500 r/minMax. Flow
1500 r/minMin. Flow
1000 r/minMax. Flow
1000 r/minMin. Flow
82
80
78
76
74
72
70
68
66
64
62
60
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
Sound pressure dataequivalent to NFPA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
Outlet Pressure – bar (psi)
1800 r/minMax. Flow
1800 r/minMin. Flow
1200 r/minMax. Flow
1200 r/minMin. Flow
69EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1200 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM131
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
240 (63)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
00 50
(700)100
(1500)150
(2200)200
(2900)250
(3600)300
(4400)350
(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Del
iver
y –
l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1500 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
120 (161)
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
720 (6372)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
70 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
8 (2.1)
7 (1.8)
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.1)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
8 (2.1)
7 (1.8)
6 (1.6)
5 (1.3)
4 (1.1)
3 (0.8)
2 (0.5)
1 (0.3)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.1)
0
Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM131
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
350(5000)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
200 (53)
160 (42)
120 (32)
80 (21)
40 (11)
0
100
90
80
70
60
50
40
30
20
10
0
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque
Input Power, Full Stroke
Input Torque and Power at 1000 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
660 (5841)
600 (5310)
540 (4779)
480 (4248)
420 (3717)
360 (3186)
300 (2655)
240 (2124)
180 (1593)
120 (1062)
60 (531)
0
100 (134)
80 (107)
60 (81)
40 (54)
20 (27)
0
71EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet260 (69)
240 (63)
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 00 500 1000 1500 2000 2500
4 (1.1)
6 (2.1)
12 (3.2)
16 (4.2)
20 (5.3)
Speed – r/min
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi), Case flow
Deliv
ery
– l/m
in (U
Sgpm
)In
put T
orqu
e –
Nm
(in.
lb.)
Case
Flo
w –
l/m
in (U
Sgpm
)
800 (7080)
700 (6195)
600 (5310)
500 (4425)
400 (3540)
300 (2655)
200 (1770)
100 (885)
0
Speed – r/min0 500 1000 1500 2000 2500
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Input Torque Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
PerformanceHigher speed version (M) PVM131
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
058
60
62
64
66
68
70
72
74
76
78
80
82
84
Noi
se L
evel
– d
BA
600 r/min Max. flow
600 r/min Min. flow
2000 r/minMax. flow
2000 r/minMin. flow
Sound pressure dataequivalent to NFPA
Typical Noise Levels at 2000 and 600 r/minwith petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
65
70
75
80
85
90
95
Over
all E
ffici
ency
(%)
Overall Efficiency Versus Speed@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
100 bar (1500 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)
50 bar (700 psi)150 bar (2200 psi)
Outlet Pressure – bar (psi)
50(700)
100(1500)
150(2200)
200(2900)
250(3600)
300(4400)
058
60
62
64
66
68
70
72
74
76
78
80
82
84
Noi
se L
evel
– d
BA
600 r/min Max. flow
600 r/min Min. flow
2000 r/minMax. flow
2000 r/minMin. flow
Sound pressure dataequivalent to NFPA
Typical Noise Levels at 2000 and 600 r/minwith petroleum oil (10 W) @ 93°C (200°F)
and 1.0 bar absolute (0 psi gauge) inlet
65
70
75
80
85
90
95
Over
all E
ffici
ency
(%)
Overall Efficiency Versus Speed@ 93°C (200°F) and 1.0 bar absolute
(0 psi gauge) inlet
0 500 1000 1500 2000 2500Speed – r/min
100 bar (1500 psi)
200 bar (2900 psi)
250 bar (3600 psi)
280 bar (4000 psi)
320 bar (4600 psi)
50 bar (700 psi)150 bar (2200 psi)
Delivery and Case Flow Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi) gauge Inlet260 (69)
240 (63)
220 (58)
200 (53)
180 (48)
160 (42)
140 (37)
120 (32)
100 (26)
80 (21)
60 (16)
40 (11)
20 (5)
0 00 500 1000 1500 2000 2500
4 (1.1)
6 (2.1)
12 (3.2)
16 (4.2)
20 (5.3)
Speed – r/min
50 bar (700 psi),Delivery
280 bar (4000 psi),Delivery
280 bar (4000 psi),Case flow
50 bar (700 psi), Case flow
Deliv
ery
– l/m
in (U
Sgpm
)In
put T
orqu
e –
Nm
(in.
lb.)
Case
Flo
w –
l/m
in (U
Sgpm
)
800 (7080)
700 (6195)
600 (5310)
500 (4425)
400 (3540)
300 (2655)
200 (1770)
100 (885)
0
Speed – r/min0 500 1000 1500 2000 2500
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Input Torque Versus Speed @ 93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
72 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM131
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min0 500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)50 (67)
60 (80)70 (94)
80 (107)90 (121)
100 (134)
110 (148)
120 (161)130 (174)
140 (188)
Inpu
t Pow
er –
kW
(hp)
0
Input Power Versus Speed @93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential,Input Torque
11 bar (160 psi) differential,Input Torque
11 bar (160 psi) differentialCase Flow
20 bar (300 psi) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w (l
/min
(USg
pm)7 (1.85)
6 (1.58)
5 (1.32)
3 (0.79)
4 (1.06)
18 (159)
16 (142)
14 (124)
12 (106)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
00 500 1000 1500 2000 2500
Input Torque and Case Flow Versus Speed @ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
17 bar (250 psi)
50 bar (700 psi)
100 bar (1500 psi)
250 bar (3600 psi)
150 bar (2200 psi)
200 bar (2900 psi)
280 bar (4000 psi)
320 bar (4600 psi)
Speed – r/min0 500 1000 1500 2000 2500
10 (13)
20 (27)
30 (40)
40 (54)50 (67)
60 (80)70 (94)
80 (107)90 (121)
100 (134)
110 (148)
120 (161)130 (174)
140 (188)
Inpu
t Pow
er –
kW
(hp)
0
Input Power Versus Speed @93°C (200°F), full flow and
1.0 bar absolute (0 psi gauge) inlet
20 bar (300 psi) differential,Input Torque
11 bar (160 psi) differential,Input Torque
11 bar (160 psi) differentialCase Flow
20 bar (300 psi) differentialCase Flow
Speed – r/min
Inpu
t Tor
que
– N
m (i
n.lb
.)
Case
Flo
w (l
/min
(USg
pm)7 (1.85)
6 (1.58)
5 (1.32)
3 (0.79)
4 (1.06)
18 (159)
16 (142)
14 (124)
12 (106)
10 (88)
8 (71)
6 (53)
4 (35)
2 (18)
00 500 1000 1500 2000 2500
Input Torque and Case Flow Versus Speed @ 93°C (200°F), load sense standby
and 1.0 bar absolute (0 psi gauge) inlet
260 (2301)240 (2124)
220 (1947)
200 (1770)
180 (1593)
160 (1416)
140 (1239)
120 (1062)
100 (885)
80 (708)
60 (531)
40 (354)20 (177)
0 500 1000 1500 2000 25008 (2.1)16 (4.2)24 (6.3)
32 (8.5)
40 (10.6)
48 (12.7)
56 (14.8)
Case
Flo
w –
l/m
in (U
Sgpm
)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Speed – r/min
280 bar (4000 psi)Input Torque
150 bar (2200 psi)Input Torque
150 bar (2200 psi), Case Flow
280 bar (4000 psi), Case Flow
Input Torque and Case Flow Versus Speed @ 93°C (200°F), cut-off and
1.0 bar absolute (0 psi gauge) inlet
18 (4.7)
16 (4.2)
14 (3.7)
12 (3.2)
10 (2.6)
8 (2.1)
6 (1.6)
4 (1.0)
2 (0.5)Case
Flo
w –
l/m
in (U
Sgpm
)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
Case Flow at 2000 r/min, Full Flow 93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
28 (7.4)
24 (6.3)
20 (5.3)
16 (4.2)
12 (3.2)
8 (2.1)
4 (1.0)
Case Flow at 2000 r/min, Minimum Flow93°C (200°F), 1.0 bar absolute (0 psi gauge) Inlet
Case
Flow
– l/
min
(USg
pm)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure – bar (psi)
250(3600)
73EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM141
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
60
62
64
66
68
70
72
74 1200 r/minmax. flow
76
78
80
82
84
1800 r/minmax. flow
1800 r/minmin. flow
1200 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
54
56
58
60
62
64
66
68
70
72
74
76
78
1500 r/minmax. flow
1000 r/minmin. flow
1000 r/minmax. flow
Typical Noise Levels 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minmin. flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 1800 and 1200 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
60
62
64
66
68
70
72
74 1200 r/minmax. flow
76
78
80
82
84
1800 r/minmax. flow
1800 r/minmin. flow
1200 r/minmin. flow
Sound pressure dataequivalent to NFPA.
Noi
se L
evel
– d
BA
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
54
56
58
60
62
64
66
68
70
72
74
76
78
1500 r/minmax. flow
1000 r/minmin. flow
1000 r/minmax. flow
Typical Noise Levels 1500 and 1000 r/minwith Petroleum Oil (10W) at 50°C (120°F)and 1.0 bar absolute (0 psi gauge) Inlet
1500 r/minmin. flow
74 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM141
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1800 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Input Torque, Cut-off
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1500 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
025 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
025 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
75EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
7,6 (2.0)
6,6 (1.75)
5,7 (1.5)
4,7 (1.25)
3,8 (1.0)
2,8 (0.75)
1,9 (0.5)
0,9 (0.25)
0
Case
Flo
w -
l/min
(USg
pm)
Case Flow Versus Outlet Pressure at Full Flow, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
Case Flow Versus Outlet Pressure at Cutoff, 1800 r/min50°C (120°F) and 1.0 bar absolute (0 psi gauge) Inlet
22,7 (6)
18,9 (5)
15,1 (4)
11,4 (3)
7,6 (2)
3.8 (1)
0
Case
Flo
w -
l/min
(USg
pm)
0 100(1500)
50(700)
200(2900)
150(2200)
300(4400)
350(5000)
Outlet Pressure - bar (psi)
250(3600)
PerformanceQuiet version, optimized for 1000-1800 rpm (E) PVM141
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
025 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Effic
ienc
y –
%
Outlet Pressure – bar (psi)
Delivery and Efficiency at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
Deliv
ery
– l/m
in (U
Sgpm
)
Volumetric Efficiency
Overall Efficiency
Delivery (effective flow)
0
50 (13)
100 (26)
150 (40)
200 (53)
250 (66)
300 (79)
0
10
20
30
40
50
60
70
80
90
100
0 100(1500)
50(700)
200(2900)
150(2200)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1200 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
025 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Power,Full Stroke
Input Torque,Full Stroke
Outlet Pressure – bar (psi)
0 100(1500)
50(700)
200(2900)
150(2200)
Outlet Pressure – bar (psi)
250(3600)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Inpu
t Pow
er –
kW
(hp)
Input Torque and Power at 1000 r/min, 50C (120F), and 1.0 bar absolute (0 psi gauge) Inlet
0
25 (34)
50 (67)
75 (101)
100 (134)
125 (168)
150 (201)
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
350 (3097)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
Input Torque,Full Stroke
Input Power,Full Stroke
76 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM141
Noi
se L
evel
– d
BA
Typical Noise Levels at 2000 and 1000 r/min with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/minmin. flow
2000 r/minmax. flow
1000 r/minmin. flow
1000 r/minmax. flow
Sound pressure dataequivalent to NFPA.
0
Speed (r/min)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)150 bar (2200 psi)
50 bar (700 psi)210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)280 (74)
40 (11)20 (5)
0
8 (2.1)6 (1.6)
10 (2.6)
4 (1.1)2 (0.5)
Deliv
ery
– l/m
in (U
Sgpm
)
Case Flowl/min
(USgpm)
100 bar (1500 psi) Delivery
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Delivery
100 bar (1500 psi) Case Flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 2000 and 1000 r/min with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/minmin. flow
2000 r/minmax. flow
1000 r/minmin. flow
1000 r/minmax. flow
Sound pressure dataequivalent to NFPA.
0
Speed (r/min)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)150 bar (2200 psi)
50 bar (700 psi)210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)280 (74)
40 (11)20 (5)
0
8 (2.1)6 (1.6)
10 (2.6)
4 (1.1)2 (0.5)
Deliv
ery
– l/m
in (U
Sgpm
)
Case Flowl/min
(USgpm)
100 bar (1500 psi) Delivery
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Delivery
100 bar (1500 psi) Case Flow
Noi
se L
evel
– d
BA
Typical Noise Levels at 2000 and 1000 r/min with Petroleum Oil (10W) at 93°C (200°F), and
1.0 bar absolute (0 psi gauge) Inlet
0 50(700)
100(1500)
150(2200)
200(2900)
250(3600)
Outlet Pressure – bar (psi)
64
66
68
70
72
74
76
78
80
82
84
86
88
2000 r/minmin. flow
2000 r/minmax. flow
1000 r/minmin. flow
1000 r/minmax. flow
Sound pressure dataequivalent to NFPA.
0
Speed (r/min)
Over
all E
ffici
ency
(%)
Overall Efficiency versus Speed at 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
55
65
75
85
95
500 1000 1500 2000 2500
50
60
70
80
100
100 bar (1500 psi)150 bar (2200 psi)
50 bar (700 psi)210 bar (3000 psi)
230 bar (3300 psi)
90
Delivery and Case Flow versus Speed at 93°C (200°F), Full Flow and 1.0 bar absolute
(0 psi gauge) Inlet
0Speed (r/min)
80 (21)
120 (32)
160 (42)
200 (53)
240 (63)
500 1000 1500 2000 2500
60 (16)
100 (26)
140 (37)
180 (48)
220 (58)
260 (69)280 (74)
40 (11)20 (5)
0
8 (2.1)6 (1.6)
10 (2.6)
4 (1.1)2 (0.5)
Deliv
ery
– l/m
in (U
Sgpm
)
Case Flowl/min
(USgpm)
100 bar (1500 psi) Delivery
210 bar (3000 psi) Case Flow
210 bar (3000 psi) Delivery
100 bar (1500 psi) Case Flow
77EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
PerformanceHigher speed version (M) PVM141
Input Torque and Case Flow versus Speed at 93°C(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)14 (124)
2 (18)1 (9)
5.0 (1.32)4.5 (1.19)
5.5 (1.45)
4.0 (1.06)3.5 (0.92)3.0 (0.79)
6.0 (1.58)6.5 (1.72)
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Input Torque
Case Flow l/min
(USgpm)
20 bar (290 psi) diff. Case Flow
11 bar (160 psi) diff. Input Torque
0Speed (r/min)
Inpu
t Pow
er –
kW
(hp)
Input Power versus Speed, 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar (700 psi)
17 bar (250 psi)
150 bar (2200 psi)
100 bar (1500 psi)
210 bar (3000 psi)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Input Torque
Case Flow l/min
(USgpm)
150 bar (2200 psi) Case Flow
210 bar (3000 psi) Input Torque
Input Torque and Case Flow versus Speed at 93°C(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)14 (124)
2 (18)1 (9)
5.0 (1.32)4.5 (1.19)
5.5 (1.45)
4.0 (1.06)3.5 (0.92)3.0 (0.79)
6.0 (1.58)6.5 (1.72)
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Input Torque
Case Flow l/min
(USgpm)
20 bar (290 psi) diff. Case Flow
11 bar (160 psi) diff. Input Torque
0Speed (r/min)
Inpu
t Pow
er –
kW
(hp)
Input Power versus Speed, 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar (700 psi)
17 bar (250 psi)
150 bar (2200 psi)
100 bar (1500 psi)
210 bar (3000 psi)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Input Torque
Case Flow l/min
(USgpm)
150 bar (2200 psi) Case Flow
210 bar (3000 psi) Input Torque
Input Torque and Case Flow versus Speed at 93°C(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)14 (124)
2 (18)1 (9)
5.0 (1.32)4.5 (1.19)
5.5 (1.45)
4.0 (1.06)3.5 (0.92)3.0 (0.79)
6.0 (1.58)6.5 (1.72)
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Input Torque
Case Flow l/min
(USgpm)
20 bar (290 psi) diff. Case Flow
11 bar (160 psi) diff. Input Torque
0Speed (r/min)
Inpu
t Pow
er –
kW
(hp)
Input Power versus Speed, 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar (700 psi)
17 bar (250 psi)
150 bar (2200 psi)
100 bar (1500 psi)
210 bar (3000 psi)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Input Torque
Case Flow l/min
(USgpm)
150 bar (2200 psi) Case Flow
210 bar (3000 psi) Input Torque
Input Torque and Case Flow versus Speed at 93°C(200°F), Load Sense Standby and 1.0 bar absolute
(0 psi gauge) Inlet
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
4 (35)
6 (53)
8 (71)
10 (89)
12 (106)
500 1000 1500 2000 2500
3 (27)
5 (44)
7 (62)
9 (80)
11 (97)
13 (115)14 (124)
2 (18)1 (9)
5.0 (1.32)4.5 (1.19)
5.5 (1.45)
4.0 (1.06)3.5 (0.92)3.0 (0.79)
6.0 (1.58)6.5 (1.72)
11 bar (160 psi) diff. Case Flow
20 bar (290 psi) diff. Input Torque
Case Flow l/min
(USgpm)
20 bar (290 psi) diff. Case Flow
11 bar (160 psi) diff. Input Torque
0Speed (r/min)
Inpu
t Pow
er –
kW
(hp)
Input Power versus Speed, 93°C (200°F),and 1.0 bar absolute (0 psi gauge) Inlet
20 (27)
40 (54)
60 (80)
80 (107)
100 (134)
500 1000 1500 2000 2500
10 (13)
30 (40)
50 (67)
70 (94)
90 (121)
110 (148)
120 (161)
50 bar (700 psi)
17 bar (250 psi)
150 bar (2200 psi)
100 bar (1500 psi)
210 bar (3000 psi)
230 bar (3300 psi)
0 1000500 20001500
Speed (r/min)
2500
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque versus Speed at 93°C (200°F),Full Flow and 1.0 bar absolute (0 psi gauge) Inlet
0
50 (442)
100 (885)
150 (1327)
200 (1770)
250 (2212)
300 (2655)
3000
150 bar (2200 psi)
100 bar (1500 psi)
50 bar (725 psi)
350 (2655)
230 bar (3300 psi)
400 (3540)
450 (3982)
500 (4425)
550 (4867)
600 (5310)
17 bar (250 psi)
210 bar (3000 psi)
0
Speed (r/min)
Inpu
t Tor
que
– N
m (i
n.lb
.)
Input Torque and Case Flow versus Speedat 93°C (200°F), Pressure Limit Cut-Off and
1.0 bar absolute (0 psi gauge) Inlet
20 (177)
40 (354)
60 (531)
80 (708)
110 (973)
500 1000 1500 2000 2500
10 (88)
30 (265)
50 (442)
70 (619)
90 (796)
100 (885)
0
20 (5.3)
15 (2.6)
10 (4.0)
5 (1.3)
210 bar (3000 psi) Case Flow
150 bar (2200 psi) Input Torque
Case Flow l/min
(USgpm)
150 bar (2200 psi) Case Flow
210 bar (3000 psi) Input Torque
78 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM018/020
Dimensions in millimeters (inches)
B
Control position for right hand (clockwise) shaft rotation, as viewed from shaft end. Position for left hand rotation is shown on following page.
165,7(6.52)
85,1(3.35)
55,2(2.17)
M M
CD
G (with adj. max. stop)
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
L
K
J
23,0(.91)
Inlet gaugeport “K.”See optionson page 107.
34,0(1.34)
34,5(1.36)
Outlet port “C.” See options on page 106.
37,4(1.47)
Drain port“F.” See options onpage 107.
∆A
H (without adj. max. stop)
Inlet port “B.”See optionson page 106.
Alt. drain port “F.” (See options on page 107.)
Load sense port “J.” (See options on page 107.)Drain port “F” (See options on page 107.)
See shaft options starting on page 102.
58,0(2.28)
76,0(2.99)
73,0(2.87)
72,0(2.83)
72,0(2.83)
58,0(2.28)
F
E
79EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM018/020
Control position for left hand rotation (Pressure compensated control shown)
Inlet position for right hand rotation (Position for left hand rotation shown below).
Adjustable maximum displacementstop (1 turn = 1.1 cm3/rev). CCWreduces displacement.
Dimensions in millimeters (inches)
Control position for right hand rotation (Load sensing control shown)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Outlet
Inlet/Outlet Ports and ControlPositioned for Left Hand Rotation
Inlet/Outlet Ports and ControlPositioned for Right Hand Rotation
37,4(1.47)
34,0(1.34)
34,5(1.36)
37,5(1.48)
140,5(5.53)
126,3(4.97)
165,7(6.52)
Control position for left hand rotation (Pressure compensated control shown)
Inlet position for right hand rotation (Position for left hand rotation shown below).
Adjustable maximum displacementstop (1 turn = 1.1 cm3/rev). CCWreduces displacement.
Dimensions in millimeters (inches)
Control position for right hand rotation (Load sensing control shown)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Outlet
Inlet/Outlet Ports and ControlPositioned for Left Hand Rotation
Inlet/Outlet Ports and ControlPositioned for Right Hand Rotation
37,4(1.47)
34,0(1.34)
34,5(1.36)
37,5(1.48)
140,5(5.53)
126,3(4.97)
165,7(6.52)
80 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM018/020
Alt. drainport “F.” Seeoptions onpage 107.
Outlet port “C” (above).See options on page 106.
Dimensions in millimeters (inches)
M
E
Load sense port “J”(See options on page 107)
See shaft options starting on page 102.
Drain port “F” (See options on page 107)
72,0(2.83)
72,0(2.83)
58,0(2.28)
F
Alt. drain port “F”(See options on page 107)
108,8(4.28)
85,1(3.35)
55,2(2.17)
CD
M M
∆A
B
G (with adj. max. stop)
H (without adj. max. stop)
23,0(.91)
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
J
K
L
Inlet port “B.” See options on page 106.
62,9(2.48)
62,9(2.48)
21,9(.86)
21,6(.85)
Inlet gaugeport “K.”See optionson page 107.
Outlet gaugeport “K.”Seeoptionson page 107.
Control position for right hand (clockwise) shaft rotation, as viewed from shaft end. Position for left hand rotation is shown on following page.
114,7(4.52)
Outlet port “C.” See options on page 106.
M
N
To pilotmtg. flg.
outletport “C.”
CL
81EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM018/020
Inlet gauge port “K.” Seeoptions on page 107.
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand rotation (Load sensing control shown)
Control position for left hand rotation (Pressure compensated control shown)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Inlet position for right hand rotation (Position for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and ControlPositioned for Left Hand Rotation
Inlet/Outlet Ports and ControlPositioned for Right Hand Rotation
62,9(2.48)
21,9(.86)
86,5(3.41)
21,6(.85)
62,9(2.48)
Outlet gauge port “K.” See options on page 107.
72,3(2.85)
Outlet gauge port “K.” Seeoptions on page 107.
Inlet gauge port “K.”Seep options on page 107.
114,7(4.52)
Inlet gauge port “K.” Seeoptions on page 107.
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
Dimensions in millimeters (inches)
Control position for right hand rotation (Load sensing control shown)
Control position for left hand rotation (Pressure compensated control shown)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Inlet position for right hand rotation (Position for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and ControlPositioned for Left Hand Rotation
Inlet/Outlet Ports and ControlPositioned for Right Hand Rotation
62,9(2.48)
21,9(.86)
86,5(3.41)
21,6(.85)
62,9(2.48)
Outlet gauge port “K.” See options on page 107.
72,3(2.85)
Outlet gauge port “K.” Seeoptions on page 107.
Inlet gauge port “K.”Seep options on page 107.
114,7(4.52)
82 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM018/020
Dimensions in millimeters (inches)
164,2(6.46)
124,0(4.88)
Load sense port “J”(See options on page 107)
Drain port “F” (See options on page 107)
72,0(2.83)
72,0(2.83)
58,0(2.28)
26,1(1.03)
Alt. drain port “F”(See options on page 107)
108,1(4.14)
85,1(3.35)
60,0(2.36)
CD
M
∆AB
221,4 (8.72)with adj. max. stop
212,3 (8.36)without adj. max. stop
23,0(.91)
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
99,0(3.90)
167,7(6.60)
223,2(8.79)
Inlet port “B.” See options on page 106.
Alt. drain port “F.” See options on page 107.
114,7(4.52)
62,9(2.48)
64,2(2.53)
Control position for right hand (clockwise) shaft rotation, as viewed from shaft end. Position for left hand rotation is shown on following page.
Centerline of outlet port
M
Outlet port “C.” See options on page 106
164,2(6.46)
to pilotmtg. flg.
See shaft options startingon page 107.
83EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM018/020
Adjustable maximum displacement stop (1 turn = 1.1 cm3/rev). CCW reduces displacement.
Dimensions in millimeters (inches)
Control position for right handrotation (Load sensing control shown)
Control position for left hand rotation(Pressure compensator control shown)
Inlet position for left handrotation (Position for right hand rotation shown above)
Outlet
Inlet position for right hand rotation (Position for left hand rotation shown below) Outlet
114,7(4.52)
62,9(2.48)
64,2(2.53)
Inlet/Outlet Ports and ControlPositioned for Left Hand Rotation
Inlet/Outlet Ports and ControlPositioned for Right Hand Rotation
86,5(3.41)
72,3(2.85)
79,4(3.13)
20,0(0.79)
20,0(0.79)
H H
K (2 places)
N (2 places)
159,2(6.27)
57,49(2.26)
40,46(1.59)
12,25(0.48)
53,5(2.11)
8,50(0.33)
2,00 (0.079)1,90 (0.075)
89,70 (3.531)89,60 (3.527)
G
27,00(1.06)
Output shaft 21T, 32/64 DP,30° PA involute spline.
Model Code Position 25 ØG H K NA,B 82,625 (3.253)
53,2 (2.09) 375-16 UNC-2B thd. 375-16 UNC-2B thd.
82,575 (3.251) 0.75 deep min 0.62 deep min.G,H 80,046 (3.151)
54,5 (2.15) M10 x 1,50 thd. M10 x 1,50 thd.
80,002 (3.150) 19,05 deep min 15,88 deep min.
Model Code Position 25 DescriptionA For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle,
involute splineB For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle,
involute splineG For ISO 80 A2HW pad with a 9T SAE splineH For ISO 80 A2HW pad with a 11T SAE spline
84 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Flange DesignationsPVM018/020
“A” Pilot Flange Designation ØA B C D E F G H J K L M
SAE J744-82-2 82,55 11,35/10,97 106,4 53,2 Model Code A (3.25) (.447/.432) (4.19) (2.09) 131,5 33,6 228,9 219,8 106,5 166,7 200,7 65,2ISO 3019/2-80A2HW 80,00 11,27/11,00 109,0 54,5 (5.18) (1.32) (9.00) (8.65) (4.19) (6.56) (7.90) (2.57) Model Code B (3.15) (.444/.433) (4.29) (2.15) “B” Pilot Flange Designation
SAE J744-101-2 101,60 14,55/14,17 146,0 73,0 Model Code C (4.00) (.572/.557) (5.750) (2.875) 124,0 26,1 221,4 212,3 99,0 159,2 193,9 87,0ISO 3019/2-100A2HW 100,00 14,27/14,00 140,0 70,0 (4.88) (1.03) (8.72) (8.36) (3.90) (6.27) (7.63) (3.43) Model Code D (3.937) (.562/.551) (5.512) (2.756)
Pilot Flange Designation ØA B C D
SAE J744-127-2 Model Code C 101,60 (4.00) 14,55/14,17 (.572/.558) 146,0 (5.75) 73,0 (2.87)ISO 3019/2-100 A2HW Model Code D 100,00 (3.94) 14,27/14,00 (.562/.551) 140,0 (5.51) 70,0 (2.76)
85EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM045/050
80,0 (3.20)
135,4 (5.33)
175,0 (6.89) 75,1(2.96)
87,1(3.43)
174,0 (6.85)
178,6 (7.03)
B
Load sense port “J.” See options on page 107.
212,0 (8.350)
Outlet gauge port “K.” See options on page 107.
Alternate drain port “F”
19,1(0.75)
Alternate load sense port “J”
42,0(1.65)
Inlet port “B.” See options on page 106.
47,8 (1.88) 53,0 (2.09)
44,6 (1.75)
130,6 (5.14)
D
87,0 (3.425)
C
E
∆A
80,0(3.15)
80,0 (3.20)
134,3 (5.29) max.
28,0 (1.10)
36,9 (1.45)
Drain port “F.” See options on page 107.
80,0(3.15)
Adjustable maximum displacement stop (1 turn = 2 cm3/rev).
Control position for left hand (counterclockwise) shaft rotation, as viewed from shaft end. Position for right hand rotation is shown on following page.
Alternate drain port “F”
257,0 (10.12) max.
247,0 (9.72)
Inlet gauge port “K”
Outlet port “C.” See options on page 106.
Dimensions in millimeters (inches)
Load sensing control (See pressure compensated control on following page.)
See shaft options starting on page 102.
86 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM045/050
Dimensions in millimeters (inches)
Non-maximum adjustment stop control cap. See preceding page for adjustable maximum displacement stop
138,5 (5.45)
Control position for left hand rotation
98,9 (3.89)
121,8 (4.80) max.34,4 (1.35)
4,0 (0.16) Control position for right hand rotation (Pressure compensated control shown)
Control position for right hand rotation
Control position for left hand rotation (Load sensing control shown)
75,1 (2.96)
87,1 (3.43)
47,8 (1.88)53,0(2.09)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Inlet position for right hand rotation (Position for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control Positioned
for Left Hand RotationDimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
Dimensions in millimeters (inches)
Non-maximum adjustment stop control cap. See preceding page for adjustable maximum displacement stop
138,5 (5.45)
Control position for left hand rotation
98,9 (3.89)
121,8 (4.80) max.34,4 (1.35)
4,0 (0.16) Control position for right hand rotation (Pressure compensated control shown)
Control position for right hand rotation
Control position for left hand rotation (Load sensing control shown)
75,1 (2.96)
87,1 (3.43)
47,8 (1.88)53,0(2.09)
Inlet position for left hand rotation (Position for right hand rotation shown above)
Outlet
Inlet position for right hand rotation (Position for left hand rotation shown below)
Outlet
Inlet/Outlet Ports and Control Positioned
for Left Hand RotationDimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Right Hand Rotation
87EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM045/050
134.3 (5.29)max.
135,4(5.33)87,0
(3.425)
174,0 (6.850)
78,0(3.07)
109,1(4.30)
191,6 (7.54)
75,5 (2.97)
Control position for right hand (clockwise) shaft rotation, as viewed from shaft end. Position for left hand rotation is shown on following page.
Drain port “F.” See options on page 107.
Load sense port “J.” See options on page 107.
Alternate drain port “F”
Inlet port “B.” See options on page 106.
257,0(10.12)max.
178,6(7.03)
36,9(1.45)
42.0 (1.65)
42.0(1.65)
168,2(6.62)
230,0(9.06)
183,0 (7.20)
208,0 (8.19)
Outlet port “C.”See options on page 106.
72,1(2.84)
Alternate drain port “F”
130,6 (5.14)
19,1 (0.75)44,6 (1.75)
E
∆A
81,3(3.20)
81,3(3.20)
Adjustable max. displacement stop (1 turn = 2 cm3/rev)
Alternate load sense port “J”
B
Dimensions in millimeters (inches)
247,0 (9.72)
DC
Z
Z
View Z-Z
72,5 (2.85) 69,0 (2.72)
Outlet gaugeport “K.”See optionon page 107.
Inlet gauge port “K”
57,50 (2.26) 50,0 (1.97)
Load sensing control (See pressure compensated control on following page.)
See shaftoptions startingon page 102.
117,6(4.63)
88 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM045/050
Control position for left hand rotation (Inlet/outlet port positions for left hand rotation are the opposite of those shown for right hand rotation on preceding page.)
Dimensions in millimeters (inches)
72,5 (2.85) 69,0 (2.72)
Outlet gauge port “K.” See options on page 107.
Inlet gauge port “K”
57,50 (2.26) 50,0 (1.97)
Non-maximum adjustment stop control cap. See preceding page for adjustable maximum displacement stop.
138,5 (5.45)
Control position for left hand rotation (Pressure compensated control shown). Inlet/outlet port positions for left hand rotation are the opposite of those shown for right hand rotation on preceding page.
98,9 (3.89)
121,8 (4.80) max. 34,4 (1.35)
4,0 (0.16) Control position for right hand rotation (Inlet/outlet port positions for right hand rotation are shown on preceding page.)
Outlet gauge port “K.” See options on page 107.
Inlet gauge port “K”
Control position for right hand rotation(Load sensing control shown). Inlet/outlet port positions for right hand rotation are shown on preceding page.
Inlet/Outlet Ports and Control Positionedfor Right Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Left Hand Rotation
Control position for left hand rotation (Inlet/outlet port positions for left hand rotation are the opposite of those shown for right hand rotation on preceding page.)
Dimensions in millimeters (inches)
72,5 (2.85) 69,0 (2.72)
Outlet gauge port “K.” See options on page 107.
Inlet gauge port “K”
57,50 (2.26) 50,0 (1.97)
Non-maximum adjustment stop control cap. See preceding page for adjustable maximum displacement stop.
138,5 (5.45)
Control position for left hand rotation (Pressure compensated control shown). Inlet/outlet port positions for left hand rotation are the opposite of those shown for right hand rotation on preceding page.
98,9 (3.89)
121,8 (4.80) max. 34,4 (1.35)
4,0 (0.16) Control position for right hand rotation (Inlet/outlet port positions for right hand rotation are shown on preceding page.)
Outlet gauge port “K.” See options on page 107.
Inlet gauge port “K”
Control position for right hand rotation(Load sensing control shown). Inlet/outlet port positions for right hand rotation are shown on preceding page.
Inlet/Outlet Ports and Control Positionedfor Right Hand Rotation
Dimensions shown on preceding page.
Inlet/Outlet Ports and Control Positioned
for Left Hand Rotation
89EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM045/050
B
Dimensions in millimeters (inches)
View “A-A”
Outletport “C.”See optionson page 106.
183,0(7.20)
208,0(8.19)
197,7(7.78)
135,8(5.35)
81,3(3.20)
81,3(3.20)
Alt. drain port “F.” See options on page 107.
Drain port “F.” See options on page 107.
36,9(1.45)
68,8(2.71)
72,3(2.85)
Left Hand Rotation
121,8(4.80)
34,4(1.35)
98,9(3.89)
Control position for R.H. rotation
Control position for L.H. rotation
138,5(5.45)
133,3(5.25)
110,8(4.36) 44,6
(1.76)
34,1(1.34)
Load sense port “J.” See options on page 107.
130,6(5.14)
78,6(3.09)
87,0(3.43)
87,0(3.43)
C
D
168,2(6.62)
249,0(9.80)
178,6(7.03)
∆A
251,0(9.88)
191,6(7.54)
Drain port “F.” See options on page 107.
11,0(0.43)
42,0 (1.65)
117,6(4.63)
Adjustable maximum displacement stop (1 turn = 2.1 cm3/rev)
Load sense control position for R.H. rotation
Load sensecontrol positionfor L.H. rotation
Right Hand RotationInlet port “B.”See options on page 106. 5,4
(0.21)
35,0(1.38)
36,0(1.42)
Inlet gauge port “K.” See options on page 107.
Outlet gauge port “K”
42,0(1.65)
A
A
Right Hand Rotation with Load Sensing Control and Tube Ports
See shaft options starting on page 102.
Flange dependent
90 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM045/050
263,5(10.37)
276,0(10.87)
86,49(3.41) 10,28
(0.40)
∆ 107,90 (4.248)107,82 (4.244)
∆G
∆ 35,30 (1.39)
L (4 places)
77,47(3.05)
11,75(0.46)
2,00 (0.079)1,90 (0.075)
86,0(3.39)2 plcs
86,0(3.39)2 plcs
H H
K (2 places)J (2 places)
J (2 places)
K (2 places)
M (4 places)
N (2 places)
Output shaft 26T, 32/64 DP, 30° PA involute spline.
53,0(2.09)
53,0(2.09)
N (2 places)
Output shaft 26T, 32/64 DP,30° PA involute spline.
Dimensions in millimeters (inches)
H H
61,74(2.43)
40,4(1.59)
12,24(0.482)
∆G
∆ 31,75 (1.25)
∆ 89,70 (3.531)89,60 (3.527)
“A” Pad
“B” Pad
Model Code Position 25 ØG H J K L M NA,B 82,58 (3.251) 53.2 – – – – .375-16 UNC-2B 82,52 (3.249) (2.09) thd. 0.60 deep min.
G,H 80,046 (3.15) 54,5 – – – – M10 thd. x 1,50 80,002 (3.149) (2.15) 15,0 deep min. 101,65 (4.002) 73,0 44,9 89,8 .500-13 UNC-2B thd. .500-13 UNC-2B .500-13 UNC-2B C,D 24.9 deep min. M12 x thd. thru M10 x thd. thru 101,60 (4.00) (2.87) (1.77) (3.54) 1,50 thd. 24,9 deep min. 1,50 thd. thru M12 x 1,50 thd. thru
J,K 100,0 (3.937) 70,0 44,2 88,38 M12 thd. x 1,50 thd. M10 x 1,50 thd. M12 x 1,50 thd. 99,946 (3.935) (2.76) (1.74) (3.48) 24,9 deep min. thru thru
Model Code Position 25 DescriptionA For SAE “A” pad with a 9T,
16/32 DP, 30° pressure angle, involute spline
B For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle, involute spline
C For SAE “B” pad with a 13T, 16/32 DP, 30° pressure angle, involute spline
D For SAE “B” pad with a 15T, 16/32 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
91EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Flange DesignationsPVM045/050
Pilot Flange Designation ØA B C D E
SAE J744-101-2 101,60/101,55 9,70/9,19
146,0 (5.750) 73,0 (2.875) 14,55/14,17
(4.000/3.998) (.382/.362) (.572/.557)
ISO 3019/2-100A2HW 100,00/99,95 9,50/9,00
140,0 (5.512) 70,0 (2.756) 14,27/14,00
(3.937/3.935) (.374/.354) (.562/.551)
Pilot Flange Designation ØA B C D SAE 2-bolt mount 101,60/101,55 (4.000/3.998) 73,0 (2.87) 146,0 (5.750) 14,55/14,17 (.572/.557)ISO 100 2-bolt mount 100,00/99,95 (3.937/3.935) 70,0 (2.76) 140,0 (5.512) 14,27/14,00 (.562/.551)
92 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM057/063
Drain port “F.” Alternate drain port “F” on opposite side. See options on page 107.
Dimensions in millimeters (inches)
Left Hand Rotation, Tube Portwith Pressure Compensator
Inlet port “B.” See options on
Outlet port “C.” See options on page 106.
206,2(8.12)
116,0(4.57)
Right Hand Rotation, Flange Port with Load Sensing Control
254,3(10,0)
199,3(7.85)
121,8(4.80)
77,5(3.05)
38,89(1.53)
77,78(3.06)
SAE .500-13UNC-2B thd. 1.06deep min.ISO M12 x 1,75 thd.29.0 deep min.
SAE .375-16 UNC-2B thd. .88 deep min. ISO M10 x 1,5 thd. 23.0 deep min.
52,38(2.06)
26,19(1.03)
165,6(6.52)
42,88(1.69)
88,7(3.49)
75,7(2.98)
21,44(.84)
26,18(1.03)
13,1(.51)
292,2(11.50)
87,0(3.43)
245,4(9.66)
201,4(7.93)
102,8(4.05)
Load sense port “J.” See options on page 107.
Outlet gauge port “K.”Inlet gauge port “K” onopposite side. Seeoptions on page 107.
39,0(1.54)
274,8(10.82)
168,2(6.62)
32,9(1.30)
157,0(6.18)
269,7(10.62)
w/o adj. max. stop
w/adj. max. stop
See mounting flange options on page 101.See shaft options starting on page 102.
Outlet port“C.” Seeoptions onpage 106.
Inlet port “B.” See optionson page 106.
82,3(3.24)
82,3(3.24)
page 106.
93EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM057/063
Dimensions in millimeters (inches)
198,1(7.80)
Left Hand Rotation with Pressure Compensator
116,0(4.57)
Right Hand Rotation with Load Sensing Control
269,7(10.62)
w/o adj. max. stop
274,8(10.82)
168,2(6.62)
32,9(1.30)
157,0(6.18)
224,4(8.83)
To mounting face
42,88(1.69)
21,44(.84)
38,89(1.53)
77,78(3.06)
Adjustable maximum displacement stop 1 turn = 2.98 l/min (0.79 USgpm)
199,3(7.85)
121,8(4.80)
77,5(3.05)
247,9(9.76)
165,6(6.52)
75,0(2.95)
75,0(2.95)
57,0(2.24)
61,5(2.42)
Inlet port “B.” See options on page 106.
SAE .500-13UNC-2B thd.1.06 deep min.ISO M12 1,75thd. 29.0 deepmin.
Outlet gauge port“K.” See optionson page 107.
Drain port “F.” Alternate drain port “F” on opposite side. See options on page 107.
Inlet gauge port “K.”See options on page 107.
102,8(4.05)
39,0(1.54)
87,0(3.43)
52,37(2.06)
26,2(1.03)
292,2(11.50)
266,5(10.49)
241,5(9.51)
213,4(8.40)
Load sense port “J.” Seeoptions on page 107.
SAE .375-16UNC-2B thd. .88deep min.ISO M10 x 1,5 thd.23.0 deep min.
Outlet port“C.” Seeoptions on page 106.
26,19(1.03)
13,1(.51)
See mounting flange options on page 101.See shaft options starting on page 102.
82,3(3.24)
82,3(3.24)
w/adj. max. stop
94 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM057/063
89,0(3.50)
Dimensions in millimeters (inches)
205,0(8.07)
Left Hand Rotation with Pressure Compensator and SAE 2-bolt “A” Flange (no adapter)
116,0(4.57)
Outlet gauge port“K.” See optionson page 107.
Inlet gauge port“K.” See optionson page 107.
Inlet port “B.” See optionson page 106.
M12 thd. 21,0 deep (4 places) ∆R
T1 (2 places)
224,4(8.83)
To mounting face
42,88(1.69)
21,44(.84)
SAE .500-13UNC-2B thd. 1.06 deep min.ISO M12 x 1,75 thd.29.0 deep min.
38,89(1.53)
77,78(3.06)
199,3(7.85)
121,8(4.80)
77,5(3.05)
254,6(10,0)
165,6(6.52)
12,0(.47)
92,0(3.62)
14,0(.55)
Right Hand Rotation with Load Sensing Control and SAE 2-bolt “A” Flange (no adapter)
80,1(3.15)
44,8(1.76)
S (See table next page)
157,0(6.18)
32,9(1.30)
168,2(6.62)
292,2(11.5)
284,4(11.2)
213,4(8.40)
39,0(1.54)
102,8(4.05)
87,0(3.43)
52,37(2.06)
26,18(1.03)
Drain port “F.” Alternate drainport “F” on opposite side.See options on page 107.
Alternate drain port “F”
Load sense port “J.” Seeoptions on page 107.
Outletport “C.”See options on page 106.
SAE .375-16UNC-2B thd. .88deep min.ISO M10 x 1,5 thd.23.0 deep min.
13,1(.52)
26,2(1.03)
See pilot flange options on page 101.See shaft options starting on page 102.
82,3(3.24)
82,3(3.24)
95EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM057/063
Dimensions in millimeters (inches)
To mounting face
To mounting face Right hand rotation with Load Sensing Control and SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,7(2.70)
Coupling length(see table)
Coupling (see table)
∆“R”
“V” Supportmounting point
(4 plcs)
35,0(1.38)
(4 plcs) “T2”
“T1”
92,0(3.62)
309,9(12.20)
297,4(11.70)
“S”
Model Code Position 25 DescriptionA SAE “A,” 9T, 16/32 DP,
30° pressure angle, involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute spline
D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
Coupling Length CodeSAE “A,” 9T 62,5 (2.46) A,GSAE “B,” 13T 93,0 (3.66) C,JSAE “B-B,” 15T 93,0 (3.66) D,KSAE “C,” 14T 93,0 (3.66) E,L
Support Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points Flange Bolt “R” “S” “T1” “T2” “V”A,B SAE “A” 2-bolt SAE Ø82,65 (3.25±.001) 8,6/8,1 (.32/.34) .375-16 UNC-2B thd. N/A N/AG,H ISO 80 ISO Ø80,05 (3.15) 9,0/8,0 (.35/.31) M10 thd. N/A N/AC,D SAE “B” 2-/4-bolt SAE Ø101,65 (4.002±.001) 12,5/11,5 (.49/.45) .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deepJ,K ISO 100 ISO Ø100,05 (3.94) 12,5/11,5 (.49/.45) M12 thd. M12 thd. M12 thd. x 25,0 deep
96 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM057/063
Support Model Code Position 25 Pilot Dia. Pilot Depth 2-bolt 4-bolt Mounting Points Flange Bolt “R” “S” “T1” “T2” “V”E,F SAE “C” 2-/4-bolt SAE Ø127,05 (5.002±.001) 15,5/14,5 (.61/.57) .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B thd. .98” deepL,M ISO 125 ISO Ø125,05 (4.92) 15,5/14,5 (.61/.57) M16 thd. M12 thd. M12 thd. x 25,0 deep
Dimensions in millimeters (inches)
“C” Adapter Flange
To mtg. face
To mtg, face
“W” (4 plcs)
35,0(1.38)
(4 plcs)
“T2”
“T1”
92,0(3.62)
Left hand rotation with Pressure Compensator and SAE 2-/4-bolt “C” Adapter Flange
309,9(12.20)
297,4(11.70) ∆ “R”
107,0(4.21)
97EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM074/081
*Right Hand Only
TO MOUNTING FACE
w/o max adj stop
Inlet port "B". See options on page 106.
Inlet gauge port "K". See options on page 107.
Outlet gauge port"K". See options on page 107.
Outlet port "C". See options on page 106.
Load sense port "J".See options on page 107.
Drain port "F". See options on page 107.
C/G locationInlet gauge port "K". See options on page 107.
Alt. drain port "F". See options on page 107.
Max. Adj. stop. One rotation will change displacement 6,1-6,8 l/min (1.6-1.8 USgpm) at 1800 rpm
Alt. drain port "F". See options on page 107.
Lifting point .375-16 UNC thd.10,0 (.39) deep with SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See options on page 107.
Left hand rotation with Pressure Compensator
Right hand rotation with Load Sensing Control
Outlet gauge port "K". See options on page 107.
86,0(3.39)
86,0(3.39)
249,6(9.83)
65,0(2.56)
65,0(2.56)
92,0(3.62)
91,0(3.58)
114,0(4.49)
114,0(4.49)
143,3(5.64)
33,0(1.30)
181,6(7.15)
246,6(9.71)
279,6(11.01)
288,0(11.34)
194,87.67( )
110,0(4.33)
Outlet port "C". See options on page 106.
319,1(12.56)
334,8(13.18)
2X 87,0(3.42)
33,9(1.33)113,6
(4.47)
102,0(4.02)
4,3(.17)
146,15.75( )
16,8(.66)
Inlet port "B". See options on page 106.
Dimensions in millimeters (inches)
See pilot flange options on page 101.See shaft options starting on page 102.
PVM074/108 is not available with left hand rotation in any port configuration.
Right hand rotation with Power/Torque limiter control
Load Sense Port 9/16-18 UNF - 2A THRD (ORS PORT)
110 (4.33)
191.8 (7.55)
200.7 (7.90) (Max length For Min Torque Setting)
158 (6.22)
98 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM074/081 *Right-hand only
TO MOUNTING FACE
Alt. drain port "F". See options on page 107.
Inlet gauge port "K". See options on page 107.
Outlet gauge port "K". See options on page 107.
Load sense port "J". See options on page 107.
Drain port "F". See options on page 107.
w/o max adj stop
Alt. drain port "F". Seeoptions on page 107.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". Seeoptions on page 107.
Inlet port "B". See options on page 106.
Inlet gauge port "K". See options on page 107.
Outlet gauge port "K". See options on page 107.
Outlet port "C". See options on page 106.
C/G location
Max. Adj. stop. One rotation will changedisplacement 6,1-7,4 l/min (1.7-1.9 USgpm) at 1800 rpm
2X T1
Dimensions in millimeters (inches)
See pilot flange options on page 101.See shaft options starting on page 102.
249,6(9.83)
92,0(3.62)
91,0(3.58)
114,0(4.49)
114,0(4.49)
143,3(5.64)
33,0(1.30)
181,6(7.15)
246,6(9.71)
194,8(7.67)
110,0(4.33)
Outlet port "C".See options on page 106.
319,1(12.56)
334,8(13.18)
2X 87,0(3.42)
33,9(1.33)113,6
(4.47)
102,0(4.02)
4,08(.16)
146,1(5.75)
14.5(0.57)
Inlet port "B". See options on page 106.
86,0(3.39)
86,0(3.39)
"A2" 45,0(1.77)
322.6(12.70)
277,6(10.93)
Left hand rotation with Pressure Compensator
Right hand rotation with Load Sensing Control
and 2-bolt“A” flange
PVM074/108 is not available with left hand rotation in any port configuration.
99EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM074/081 *Right-hand only
“T1”
“T2”
To mtg, face
To mtg, face
View rotated 90°
4X “W”“A1”
“A2”
92,0(3.62)
“A1”
335,1(13.19)
372,6(14.68)
4X 35,0(1.38)
Dimensions in millimeters (inches)
Right hand rotation with Load Sensing Control and ISO or SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,3(2.69)
Coupling length(See table)
25,0 (.98)
Coupling (see table)
“S”
“R3”
“R1” “R2"
43,3(1.70) “S”
“R3”
“R1” “R2”
Coupling (see table)Coupling length (see table)
With adapter plate Without adapter plate
Model code Position 25 DescriptionA SAE “A,” 9T, 16/32 DP,
30° pressure angle, involute spline
B SAE “A,” 11T, 16/32 DP, 30° pressure angle, involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute spline
D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11 T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
M For ISO 125-A2/B4HW pad with a 17T SAE spline
Coupling Length CodeSAE “A,” 9T 64,5 (2.54) A,GSAE “A,” 11T 65,3 (2.57) B,HSAE “B,” 13T 95,3 (3.75) C,JSAE “B-B,” 15T 95,3 (3.75) D,KSAE “C,” 14T 95,3 (3.75) E,LSAE “C-C,” 17T 91,8 (3.61) F,M
Model Code Position 25 Pilot O-ring O-ring Pilot Support Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt “R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B thd. N/A N/A N/A 53,2 G,H 2-bolt (3.25) (3.53) 1,90 (.07) (.35/.31) ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5 (3.15) (3.53) 2,60 (.10) (.35/.31) (2.15)C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0 J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98”deep(1.77) (2.87) ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0 (3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)
100 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
To mtg, face
To mtg, face
“T1”
“T2”
View rotated 90∞
4X “W”
92,0(3.62)
“A1”
“A1”
“A2”
335,1(13.19)
347,6(13.69)
35,0(1.38)
4X
Dimensions in millimeters (inches)
“C” Adapter Flange
Left hand rotation with Pressure Compensatorand ISO or SAE 2-/4-bolt “C” Adapter Flange
Thru-drive ModelsPVM074/081 *Right-hand only
Model Code Position 25 Pilot O-ring O-ring Pilot Support Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points “R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5 L,M 2-/4-bolt thd. .98” deep (2.25) (3.56) ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 25,0 deep 56,57 90,0 (4.92) (3.26) 2,60 (.10) (.61/.57) (2.23) (3.54)
101EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM098/106
w/o max adj stop
To mounting face
C/G location
Drain port “F”. See options on page 107.
Load sense port “J”. See options on page 107.
Inlet gauge port “K”. See options on page 107.
Outlet gauge port “K”. See options on page 107.
Max. Adj. stop. One rotation will change displacement 7,9-8,7 l/min (2.1-2.3 USgpm) at 1800 rpm
Alt. drain port “F”. See options on page 107.
Alt. drain port “F”. Seeoptions on page 107.
Lifting point .375-16 UNC thd.10,0 (.39) deep with SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port “F”. See options on page 107.
Outlet port “C”. See options on page 106.
Inlet port “B”. See options on page 106.
Outlet gauge port“K”. See options on page 107.
Inlet gauge port “K”. See options on page 107.
Left hand rotation with Pressure Compensator
Left hand rotation with Load Sensing Control
Dimensions in millimeters (inches)
See pilot flange options on page 101.See shaft options starting on page 102.
214,6(8.45)
107,5(4.23)
2X 194,5(7.66)
266,9(10.51)
305,6(12.03)
322,6(12.70)
37,0(1.46)
91,0(3.58)
98,0(3.86)
70,0(2.76)
70,0(2.76)
119,0(4.69)
119,0(4.69)
90,0(3.54)
92,5(3.64)
276,9(10.90)
33,9(1.33)
115,5(4.55)
342,4(13.48)
357,8(14.09)
2X 95,0(3.74)
162,0(6.38)
170,6(6.72)
Inlet port “B”. Seeoptions on page 106.
155,7(6.13)
35,5(1.40)
Outlet port “C”. See options on page 106.
16,4(.65)
121,0(4.76)
PVM098/106 is not available in left hand rotation with rear ports.
102 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM098/106
w/o max adj stop
Alt. drain port "F". Seeoptions on page 107.
Lifting point .375-16 UNC thd. 10,0 (.39) deep with SAE drain M10 thd. 10,0 (.39) deep with ISO drain
Alt. drain port "F". See options on page 107.
Inlet gauge port "K". See options on page 107.
Outlet gauge port "K". See options on page 107.
To mounting face
Max. Adj. stop. One rotation will changedisplacement 7,9-8,7 l/min (2.1-2.3 USgpm) at 1800 rpm
C/G location
Drain port "F". See options on page 107.
Alt. drain port "F". See options on page 107.
Load sense port "J".See options on page 107.
Outlet port "C". See options on page 106.
Inlet port "B". See options on page 106.
Outlet gauge port "K". See options on page 107.
Inlet gauge port "K". See options on page 104.
2X T1
Dimensions in millimeters (inches)
See pilot flange options on page 101.See shaft options starting on page 102.
Left hand rotation with Pressure Compensator
Right hand rotation with 2-bolt “A” flangeand Load Sensing Control
214,6(8.45)
107,5(4.23)
2X 194,5(7.66)
266,9(10.51)
2X37,0(1.46)
91,0(3.58)
98,0(3.86)
119,0(4.69)
119,0(4.69)
90,0(3.54)
92,5(3.64)
276,9(10.90)
33,9(1.33)
115,5(4.55)
342,4(13.48)
357,8(14.09)
2X 95,0(3.74)
162,0(6.38)
170,6(6.72)
Inlet port "B". Seeoptions on page 106.
164,4(6.47)
36,6(1.44)
Outlet port "C". See options on page 106.
17,3(0.68)
121,0(4.76)
45,0(1.77)
A2*
42,0(1.65)
150,0(5.91)
347,9(13.70)
PVM098/106 is not available in left hand rotation with rear ports.
103EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
“T1”
“T2”
92,0(3.62)
“A1”
“A1”“A2”
4X 35,0(1.38)
360,4(14.19)
372,6(14.68)
To mtg, face
To mtg, face
4X “W” Supportmounting points
View Rotated 90° Right hand rotation with Load Sensing Control
“B” Adaptor Flange
COMBINE WITH EXISTING GRAPHIC
FOR THIS PAGE
Thru-drive ModelsPVM098/106
Dimensions in millimeters (inches)
View Rotated 90°
To mtg, face
To mtg, face
Right hand rotation with “CV” compensation and ISO or SAE 2-/4-bolt “B” adapter flange
“B” Adapter Flange
68,3(2.69)
Coupling length (see table)
25,0(.98)
Coupling (see table)
“S”
“R3”
“R1” “R2”
43,3(1.70) “S”
“R3”
“R1” “R2”
Coupling (see table)Coupling length(see table)
“V” Supportmounting points (4 plcs)
35,0(1.38)
(4 plcs)
“A2”
“A1”
“T2”
“T1”92,0(3.62)
“A1”
372,9(14.68)
360,4(14.19)
With adapter plate Without adapter plate
Coupling Length CodeSAE “A,” 9T 64,5 (2.54) A,GSAE “A,” 11T 65,3 (2.57) B,HSAE “B,” 13T 95,3 (3.75) C,JSAE “B-B,” 15T 95,3 (3.75) D,KSAE “C,” 14T 95,3 (3.75) E,LSAE “C-C,” 17T 91,8 (3.61) F,M
Model Code Position 25 DescriptionA SAE “A,” 9T, 16/32 DP,
30° pressure angle, involute spline
B SAE “A,” 11T, 16/32 DP, 30° pressure angle, involute spline
C SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute spline
D SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute spline
E SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute spline
F SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, involute spline
G For ISO 80-A2HW pad with a 9T SAE spline
H For ISO 80-A2HW pad with a 11 T SAE spline
J For ISO 100-A2/B4HW pad with a 13T SAE spline
K For ISO 100-A2/B4HW pad with a 15T SAE spline
L For ISO 125-A2/B4HW pad with a 14T SAE spline
M For ISO 125-A2/B4HW pad with a 17T SAE spline
Model Code Position 25 Pilot O-ring O-ring Pilot Support Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points 4-bolt 2-bolt “R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”A,B SAE “A” SAE Ø82,6 Ø89,65 2,00 (.08) 9,0/8,0 375-16 UNC-2B N/A N/A N/A 53,2 G,H 2-bolt (3.25) (3.53) 1,90 (.07) (.35/.31) thd. 0.59 deep ISO 80 ISO Ø80,05 Ø89,75 2,70 (.11) 9,0/8,0 M10 thd. N/A N/A N/A 54,5 (3.15) (3.53) 2,60 (.10) (.35/.31) x 18,0 deep (2.15)C,D SAE “B” SAE Ø101,65 Ø108,05 2,00 (.08) 12,5/11,5 .50-13 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 44,9 73,0 J,K 2-/4-bolt (4.00) (4.25) 1,90 (.07) (.49/.45) thd. .98” deep (1.77) (2.87) ISO 100 ISO Ø100,05 Ø108,75 2,70 (.11) 12,5/11,5 M12 thd. M10 thd. M12 thd. 25,0 deep 44,19 70,0 (3.94) (4.28) 2,60 (.10) (.49/.45) (1.74) (2.76)
104 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM098/106
To mtg, face
To mtg, face
4X “W” Support mounting points
View Rotated 90°
“T2”
“T1”
372,9(14.68)
4X 35,0(1.38)
360,4(14.19)
“A1”
“A2”
“A1” 92,0(3.62)
Dimensions in millimeters (inches)
“C” Adapter Flange
Left hand rotation with Pressure Compensatorand ISO or SAE 2-/4-bolt “C” adapter flange
Model Code Position 25 Pilot O-ring O-ring Pilot Support Flange Bolt Dia. Dia. Depth Depth 2-bolt 4-bolt Mounting Points “R1” “R2” “R3” “S” “T1” “T2” “W” “A1” “A2”E,F SAE “C” SAE Ø127,05 Ø133,45 2,00 (.08) 15,5/14,5 .625-11 UNC-2B thd. .50-13 UNC-2B thd. .50-13 UNC-2B 57,25 90,5 L,M 2-/4-bolt thd. .98” deep (2.25) (3.56) ISO 125 ISO Ø125,05 Ø133,75 2,70 (.11) 15,5/14,5 M16 thd. M12 thd. M12 thd. 56,57 90,0 (4.92) (3.26) 2,60 (.10) (.61/.57) 25,0 deep (2.23) (3.54)
105EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
End-ported ModelsPVM131/141
See pilot flange options on page 101.See shaft options starting on page 102.
115,0(4.53)
Dimensions in millimeters (inches)
111,5(4.39)2 plcs.
143,5 (5.65)
“F3” 192,6 (7.58)2 plcs.
346,1 (13.63) max. lengthw/o max. adj. stop
122,6 (4.83) 2 plcs.
“F” drain port
Lifting point.500-13 UNC-2B thd.18,0 (.709) dp. 2 plcs.
65,0 (2.56) 2 plcs. 55,0 (2.17) 2 plcs.
330,6 (13.02)
“K” Inletgage port
25,0(0.98)
172,0(6.77)
34,0(1.34)
369,4 (14.54)
230,4 (9.07)
Optional drain port “F”
“F2”
“B2” 4 plcs.
“K” Inletgage port
“B” inlet port
Right hand rotation withLoad Sensing Control
104,2(4.10)
91,5(3.60)
49,7 (1.95)
64,0(2.52)
“J” Load sense signal port
132,7 (5.22)
110,5 (4.35) R.H.94,5 (3.72) L.H.
“C2” 4 plcs.
“K” Outletgage port
“C” outletport
180,6 (7.11)
131,0(5.16)132,7
(5.22)
“C”outletport
“K”Outlet gageport
Left hand rotationwith Pressure Compensator
“B” inlet port
“K”Inletgageport
Adjustable maximum stop option.Torque locknut to 37-45 Nm (27-33 lb ft).One turn of screw wil change pumpdisplacement 5,7 cm3/rev (0.35 in3/rev).Turn CCW to destroke.
106,0 (4.17)
55,0(2.17)
Optional drainport “F”
106 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Side-ported ModelsPVM131/141
See pilot flange options on page 101.See shaft options starting on page 102.
“C2” 4 plcs.
“C”outletport
Outlet gage port “K”
70,0(2.76)
346,1 (13.63) max. lengthw/o max. adj. stop
143,5(5.70)
Dimensions in millimeters (inches)
115,0(4.53)
172,0(6.77)
34,0(1.34)
369,4 (14.54)
230,4 (9.07)
Optional drain port “F”
280,4 (11.04) outletport
CL
100,0 (3.94)
131,0 (5.16)
132,7(5.22)
Left hand rotation withPressure Compensator
Inlet port “B”
Inlet gageport “K”
Outlet gage port “K”
Outlet port “C.”
111,5(4.39)2 plcs.
“F3”
122,6(4.82)2 plcs.
65,0 (2.56) 2 plcs.55,0 (2.16) 2 plcs.
192,6 (7.58)2 plcs.
298.6 (11.76)
“F” drain port
Lifting point.500-13 UNC-2B thd.18.0 (.709) dp. 2 plcs.
Inlet port “B”
“B2”4 plcs.
180,6 (7.11)
“F2”
106,0(4.17)
Right hand rotation withLoad Sensing Control
95.0(3.74)
70,0(2.76)
“J” Load sense signal port
132,7 (5.22)110,5 (4.35) R.H.94,5 (3.72) L.H.
Optional drainport “F”
Inlet gageport “K”
A
A
View A - A Outlet port
280,4 (11.04)
ref.
318,1 (12.52) gage port spotface
341,1 (13.43) gage port spotface
Adjustable maximum stop option.Torque locknut to 37-45 Nm (27-33 lb ft).One turn of screw will change pumpdisplacement 5,7 cm3/rev (0.35 in3/rev)
55,0 (2.17)
Right hand rotation with Power/Torque limiter control
85 (7.28)
221.6 (8.73) (Max length For Min Torque Setting)
110.5 (4.35)
220.8 (8.69)
Load Sense Port 9/16-18 UNF - 2A THRD (ORS PORT)
107EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM131/141
See pilot flange options on page 101.See shaft options starting on page 102.
369,4(14.54)
346,1(13.63) w/o max.
adj. stop122,6(4.83)
Left Hand Rotation with Pressure Compensatorand SAE 2-bolt “A” Flange (no adapter)
Right Hand Rotation with Load Sensing Control and SAE 2-bolt “A” Flange (no adapter)
173,0(6.81)
192,6(7.58)
298,6(11.76)
∆ “Q” See table below
65,0(2.56)
55,0(2.17)
305,6(12.03)
143,5(5.65)
SAE port 116,1 (4.57)ISO port 150,0 (5.91)
Inlet gage port “K”
54,5(2.15)
15,0(.59)
Inlet port “B.” Seeoptions on page 106.
SAE .500-13 UNC-2Bthd. 1.19 deep min. orISO M12 x 31.0 deep min.
SAE .500-13 UNC-2Bthd. 1.00 deep min. orISO M12 x 27.0 deep min.
180,6(7.11)
111,5(4.39)
106,0(4.17)
55,0(2.16)
11,5(.45)
100,0(3.94)
SAE port 116,1 (4.57)ISO port 150,0 (5.91)
95,0(3.74)
40,0(1.57)
4,0(.16)
Inlet gageport “K.” See options on page 107.
Outlet gage port “K.” Seeoptions on page 107.
Alt. drain port “F.” Seeoptions on page 107.
Load sense port “J.” See options on page 107.
132,7(5.22)
313,6(12.35)
280,4(11.04)
45,0(1.77)
Outlet port “C.”See options onpage 106.
“Q2” See table below
Outlet port “C.”See options onpage 106.
Inlet port “B.”See options onpage 106.
132,7(5.22)
131,0(5.16)
Drain port “F.” See options on page 107.
172,0(6.77)
347,1(13.67)
230,4(9.07)
80,0(3.15)
44,7(1.76)
8,5 (.33)
14,0 (.55) A919,0 (.75) A11
See coupling code below
See output shaft below
Dimensions in millimeters (inches)
34,0(1.33)
280,4(11.04)
outletport
CL
Model Code Position 25 “Q1” Thru-drive Flange “Q2” 2-bolt ThreadA,B SAE J744-82-2 .375-16 UNC-2B Ø82.625/82.575 bore thd. 0.80 deepG,H ISO 3019/2-80A2 M10 thd. x 18,0 deep Ø80.075/80.25 bore
108 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM131/141
Right Hand Rotation with SAE 2-/4-Bolt “B”Flange and ISO 100 Adapter Flange
372,1 (14.65)
359,6 (14.16)
35,0 (1.38) 4 places
“R2” - 2 places
“R3” 4 places
∆ “R1” 92,0 (3.62) 4 places
69,7 (2.74)
14,0 (.55)
O-ring (furnished)
Coupling (See table)
Dimensions in millimeters (inches)
“B” Adapter Flange
“R4” (4 plcs)
Model Code Position 25 DescriptionA For SAE “A” pad with a 9T, 16/32 DP, 30° pressure angle, involute splineB For SAE “A” pad with a 11T, 16/32 DP, 30° pressure angle, involute spline Output shaft 14T 12/24 DP external involute splineC SAE “B,” 13T, 16/32 DP, 30° pressure angle, involute splineD SAE “B-B,” 15T, 16/32 DP, 30° pressure angle, involute
splineE SAE “C,” 14T, 12/24 DP, 30° pressure angle, involute splineF SAE “C-C,” 17T, 12/24 DP, 30° pressure angle, involute
splineG For ISO 80-A2HW pad with a 9T SAE splineH For ISO 80-A2HW pad with a 11T SAE splineJ For ISO 100-A2/B4HW pad with a 13T SAE splineK For ISO 100-A2/B4HW pad with a 15T SAE splineL For ISO 125-A2/B4HW pad with a 14T SAE splineM For ISO 125-A2/B4HW pad with a 17T SAE spline
Model Code Position 25 “R1” Thru-drive Flange “R2” 2-bolt Thread “R3” 4-bolt Thread “R4” Support Mounting PointsC,D SAE J744-101-2 & -4 .500-13 UNC-2B .500-13 UNC-2B .500-13 UNC-2B Ø101,675/101.625 bore 12,50/11,50 deep 0.98 deep 0.98 deep 0.98 deepJ,K ISO 3019/2-100A2 & B2 M12 M12 M12 Ø100,075/100.025 bore 12,50/11,50 deep 25,0 deep 25,0 deep 25,0 deep
109EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Thru-drive ModelsPVM131/141
359,6 (14.16)
372,1 (14.65)
“S4” 4 places
35,0 (1.38)4 places
92,0 (3.62) 4 places∆ “S1”
“S2”2 places
“S3”4 places
Left Hand Rotation with SAE 2-/4-bolt “C” and ISO 125 Adapter Flange
Dimensions in millimeters (inches)
“C” Adapter Flange
Model Code Position 25 “S1” Thru-drive Flange “S2” 2-bolt Thread “S3” 4-bolt Thread “R4” Support Mounting PointsE,F SAE J744-127-2 & -4 .625-11 UNC-2B .500-13 UNC-2B .500-13 UNC-2B Ø127,075/127.025 bore 15,50/14,50 deep 0.98 deep 0.98 deep 0.98 deepL,M ISO 3019/2-125A2 & B4 M16 M12 M12 Ø125,075/125.025 bore 15,50/14,50 deep 25,0 deep 25,0 deep 25,0 deep
Port “B”* “B2” “C”* “C2” “F2” “F3”
SAE 2.50 inch dia. SAE J518 .500-13 UNC-2B thd. 1.25 inch dia. SAE J518 .500-13 UNC-2B thd. 146,8 114,9 Code 61, low pressure 1.19 deep minimum Code 62, high pressure 1.00 deep minimum (5.78) (4.52)
ISO 64mm diameter. ISO M12 thread 32mm diameter. M12 thread 148,5 116,6 6162 Type II, 315 bar 31,0 deep minimum ISO 6162, 400 bar 27,0 deep minimum (5.85) (4.59)*4-bolt flange port. See page 101 for load sensing, drain, and gage port threads.
110 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Mounting Flange Options
A
∆ J pilot
E
F
G
H
G
H
∆ J pilot
A45°
K
KL
L
Dimensions in millimeters (inches)
2-bolt “A, B & C” FlangeISO & SAE
2-bolt “B” Flange4-bolt “C” or “D” Flange
ISO & SAE
2-bolt or 4-bolt Series Flange Code Flange Description A E F G H J K L
PVM018 2-bolt A SAE J744-82-2 Ø11,14 53,2 106,4 – – Ø82,53 +.02 -.03 – – PVM020 “A” (4.38) (2.09) (4.19) – – (Ø3.249) +.000 -.001
PVM018 2-bolt B ISO 3019/2-80A2HW Ø11,14 54,5 109,0 – – Ø79,98 +.02 -.03 – – PVM020 “A” (4.38) (2.15) (4.29) – – (Ø3.15) +.000 -.001
PVM018 PVM020 PVM045 2-bolt C SAE J744-101-2 14,36 73,0 146,0 – – Ø101,58+.02 PVM050 “B” -.03 – – PVM057 (.565) (2.87) (5.75) – – (Ø3.999) ±.001 PVM063
PVM018 PVM020 PVM045 2-bolt D ISO 3019/2-100A2HW 14,14 70,0 140,0 – – Ø100,00/99,95 – – PVM050 “B” (special) (.557) (2.76) (5.51) (Ø3.937/3.935) PVM057 PVM063
PVM057 E SAE J744-127-2 (“C”) 17,4 90,5 181,0 – – Ø127,00/126,95 – –
PVM063 2-bolt (.685) (3.562) (7.125) (Ø5.000/4.998)
PVM074 “C” F ISO 3019/2-125A2HW 18,0 90,0 180,0 – – Ø125,00/124,95 – – PVM081 (.709) (3.543) (7.09) (Ø4.921/4.919) PVM098 G SAE J744-127-4 (“C”) 14,2 – – 57,25 114,50 Ø127,00/126,95 – – PVM106 4-bolt (.559) (2.254) (4.508) (Ø5.000/4.998) PVM131 “C” H ISO 3019/2-125B4HW 14,0 – – – – Ø125,00/124,95 80,0 160,0 PVM141 (.551) (Ø4.921/4.919) (3.150) (6.299) J SAE J744-152-4 (“D”) 20,6 – – 80,82 161,64 Ø152,40/152,35 – – PVM131 4-bolt (.812) (3.182) (6.364) (Ø6.000/5.998) PVM141 “D” K ISO 3019/2-160B4HW 18,0 – – – – Ø160,00/159,95 100,0 200,0 (.709) (Ø6.299/6.297) (3.937) (7.874)*Flanges for PVM020 and PVM050 are shown on pages 73 and 80, respectively.
111EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Shaft Options
B spline
C
D
Dimensions in millimeters (inches)
SAE Splined Shaft
∆A
SAE Spline Shaft Max. Input Torque Model Series Designation Shaft Code A max. B C D Nm (lb. in.) SAE J744-16-4 03 15,88 (.625) 9T 16/32 DP 37,0 (1.46) 32,0 (1.26) 58 (517) SAE “A” (9T) SAE J744-19-4 04 19,05 (.750) 11T 16/32 DP 30,0 (1.18) 38,0 (1.50) 123 (1100)
PVM018/020 SAE “A” (11T) SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850) SAE “B” (13T) SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987) SAE “B-B” (15T) SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850)
PVM045/050 SAE “B” (13T) SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987) SAE “B-B” (15T) SAE J744-22-4 07 21,81 (.859) 13T 16/32 DP 33,0 (1.31) 41,0 (1.61) 208 (1850) SAE “B” (13T)
PVM057/063 SAE J744-25-4 08 24,98 (.983) 15T 16/32 DP 38,0 (1.50) 46,0 (1.81) 337 (2987) SAE “B-B” (15T) SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660) SAE “C” (14T) SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660) PVM074/081 SAE “C” (14T)PVM098/106 SAE J744-38-4 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750) SAE “C-C” (17T) SAE J744-32-4 11 31,22 (1.23) 14T 12/24 DP 48,0 (1.89) 56,0 (2.20) 640 (5660) SAE “C” (14T)
PVM131/141 SAE J744-38-4 12 37,57 (1.479) 17T 12/24 DP 54,0 (2.13) 62,0 (2.44) 1215 (10,750) SAE “C-C” (17T) SAE J744-44-4 14 43,71 (1.721) 13T 8/16 DP 67,0 (2.63) 75,0 (2.95) 1215 (10,750) SAE “D” (13T)
112 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Shaft Options
Dimensions in millimeters (inches)
D
C
B ∆ A
SAE Keyed Shaft
E key
Max. Input SAE Keyed Shaft Shaft Torque Model Series Designation Code A B C D E Nm (lb. in.) SAE J744-16-1 01 15,88 (.625) 17,73 (.698) 24,0 (.94) 32,0 (1.26) 4,0 (.157) 58 SAE “A” (517) SAE J744-19-1 02 19,05 (.750) 21,23 (.836) 24,0 (.94) 32,0 (1.26) 4,81 (.189) 104
PVM018/020 SAE “19-1” (918) SAE J744-22-1 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) 135 SAE “B” (1200) SAE J744-25-1 06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250) 215 SAE “B-B” (1900) SAE J744-22-1 05 22,22 (.875) 25,12 (.989) 33,0 (1.31) 41,0 (1.61) 6,35 (.250) 135
PVM045/050 SAE “B” (1200) SAE J744-25-1 06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250) 215 SAE “B-B” (1900) SAE J744-25-1 06 25,37 (.999) 28,22 (1.111) 38,0 (1.50) 46,0 (1.81) 6,35 (.250) 215
PVM057/063 SAE “B-B” (1900) SAE J744-32-1 09 31,75 (1.25) 35,32 (1.390) 48,0 (1.89) 56,0 (2.20) 7,93 (.312) 450 SAE “C” (3980) SAE J744-32-1 09 31,75 (1.25) 35,32 (1.390)48,0 (1.89) 56,0 (2.20) 7,93 (.312) 450 PVM074/081 SAE “C” (3980)PVM098/106 SAE J744-38-1 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375) 765 SAE “C-C” (6770) SAE J744-32-1 09 31,75 (1.25) 35,32 (1.390)48,0 (1.89) 56,0 (2.20) 7,93 (.312) 450 SAE “C” (3980)
PVM131/141 SAE J744-38-1 10 38,10 (1.50) 42,39 (1.67) 54,0 (2.13) 62,0 (2.44) 9,52 (.375) 765 SAE “C-C” (6770) SAE J744-44-1 13 44,45 (1.75) 49,46 (1.95) 67,0 (2.63) 75,0 (2.95) 11,11 (.438) 1200 SAE “D” (10,620)
113EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Dimensions in millimeters (inches)
C
∆ A
B
E
ISO Keyed Shaft
D key
Shaft Options
Max. Input ISO Keyed Shaft Shaft Torque Model Series Designation Code A B C D E Nm (lb. in.) ISO 3019/2 E20N 15 19,9 (.786) 8,5 (.335) 36 (1.42) 6 (.236) 22,5 (.886) 113 (1000)
PVM018/020 ISO 3019/2 E25N Short Spigot 16 25 (.984) 8,5 (.335) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900) ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)PVM045/050 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900)PVM057/063 ISO 3019/2 E25N 17 25 (.984) 10 (.393) 42 (1.65) 8 (.315) 28,0 (1.102) 215 (1900) ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)PVM074/081 ISO 3019/2 E32N 18 32 (1.26) 10,5 (.413) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980)PVM098/106 ISO 3019/2 E40N 19 40 (1.57) 10,5 (.413) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)PVM131/141 ISO 3019/2 E32N 18 32 (1.26) 10 (.393) 58 (2.28) 10 (.394) 35,0 (1.378) 450 (3980) ISO 3019/2 E40N 19 40 (1.57) 10 (.393) 82 (3.23) 12 (.472) 43,0 (1.693) 870 (7700)(1)ISO 80mm pilot only – B(2)ISO 80mm pilot only – D*Torque of non-thru-drive PVM pump, or combined torque of PVM thru-drive pump and thru-driven pump.NOTE: In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified,
consult Eaton Engineering for specific limits.
114 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Input Shaft Selection Data
SAE Splined Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡ Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.) SAE J744-16-4 (SAE “A,” 9T) 03 58 (513) Exceeds maximum input torque
PVM018/020 SAE J744-19-4 (SAE “A,” 11T) 04 123 (1100) Exceeds maximum input torque SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 123 (1100) SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 123 (1100)
PVM045/050 SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*
SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987) SAE J744-22-4 (SAE “B,” 13T) 07 208 (1850) 208 (1850)*PVM057/063 SAE J744-25-4 (SAE “B-B,” 15T) 08 337 (2987) 337 (2987) SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 337 (2987)
PVM074/081 SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 515 (4560)PVM098/106 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 515 (4560) SAE J744-32-4 (SAE “C,” 14T) 11 640 (5660) 640 (5660)PVM131/141 SAE J744-38-4 (SAE “C-C,” 17T) 12 1215 (10,750) 640 (5660) SAE J744-44-4 (SAE “D,” 13T) 14 1215 (10,750) 640 (5660)
SAE Keyed Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡ Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.) SAE J744-16-1 (SAE “A”) 01 58 (513) Exceeds maximum input torque
PVM018/020 SAE J744-19-1 (SAE “19-1”) 02 104 (920) Exceeds maximum input torque
SAE J744-22-1 (SAE “B”) 05 135 (1200) 123 (1100) SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 123 (1100)
PVM045/050 SAE J744-22-1 (SAE “B”) 05 135 (1200) 135 (1200)*
SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
PVM057/063 SAE J744-25-1 (SAE “B-B”) 06 215 (1900) 215 (1900)*
SAE J744-32-1 (SAE “C”) 09 450 (3980) 337 (2987)PVM074/081 SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*PVM098/106 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 515 (4560) SAE J744-32-1 (SAE “C”) 09 450 (3980) 450 (3980)*PVM131/141 SAE J744-38-1 (SAE “C-C”) 10 765 (6770) 640 (5660) SAE J744-44-1 (SAE “D”) 13 1200 (10,620) 640 (5660)
ISO Keyed Shafts
Max. Input Torque† Max. Thru-drive Output Torque‡ Model Series Shaft Designation Shaft Code Nm (lb. in.) Nm (lb. in.) ISO 3019/2 E20N (B mount only) 15 113 (1000) Exceeds maximum input torquePVM018/020 ISO 3019/2 E25N (B mount only) 16 215 (1900) Exceeds maximum input torque ISO 3019/2 E25N (D mount only) 17 215 (1900) 123 (1100)PVM045/050 ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
PVM057/063 ISO 3019/2 E25N 17 215 (1900) 215 (1900)*
ISO 3019/2 E32N 18 450 (3980) 337 (2987)
PVM074/081 ISO 3019/2 E32N 18 450 (3980) 450 (3980)*PVM098/106 ISO 3019/2 E40N 19 870 (7700) 515 (4560)
PVM131/141 ISO 3019/2 E32N 18 450 (3980) 450 (3980)*
ISO 3019/2 E40N 19 870 (7700) 640 (5660)†Maximum total torque of the thru-drive pump and the thru-driven pump(s).
‡Maximum torque that can be applied to the thru-driven pump(s).
*This value is limited by the maximum input torque.
115EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Port Options
Inlet and Outlet Ports
Inlet/Outlet Port Option Port Model Series (per model code, page 5) Code Inlet Port “B” Outlet Port “C” Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure. 1.25 inch diameter, .4375-14 x 1.12 bolt holes 0.75 inches diameter, .375-16 x .88 bolt holes Metric Flange 04 ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar. PVM018/020 31,75mm diameter, M10 x 28 bolt holes 19,05mm diameter, M10 x 22 bolt holes Inch Tube 01 SAE J514 O-ring –20, for 1-1/4 inch O.D. tube SAE J514 O-ring -12, for 3/4 inch O.D. tube Metric Tube 03 ISO 6149-1, M42 thread ISO 6149-1, M27 thread British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/4 thread ISO 228-1:1994 (E), G 3/4 thread Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure. 2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .87 bolt holes Metric Flange 04 ISO 6162 Type II, 315 bar. ISO 6162 Type II, 315 bar. PVM045/050 51mm diameter, M12 x 27 bolt holes 25mm diameter, M10 x 22 bolt holes Inch Tube 01 SAE J514 O-ring -24, for 1-1/2 inch O.D. tube SAE J514 O-ring -16, for 1 inch O.D. tube Metric Tube 03 ISO 6149-1, M48 thread ISO 6149-1, M33 thread British Parallel Pipe 05 ISO 228-1:1994 (E), G 1-1/2 thread ISO 228-1:1994 (E), G1 thread Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure. 2.00 inch diameter, .500-13 x 1.06 bolt holes 1.00 inch diameter, .375-16 x .88 bolt holes Metric Flange 04 ISO 6162 Type II, 350 bar. ISO 6162 Type, 350 bar.
PVM057/063 51mm diameter, M12 x 29 bolt holes 25mm diameter, M10 x 23 bolt holes
Inch Tube 01 SAE J514 O-ring -24, SAE J514 O-ring (End ported models only) for 1-1/2 inch O.D. tube -16 for 1 inch O.D. tube Metric Tube 03 ISO 6149-1, M48 thread ISO 6149–1, M33 thread (End ported models only) Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
PVM074/081 2.00 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
Metric Flange 04 ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar. 51mm diameter, M12 x 20 bolt holes 25mm diameter, M10 x 17 bolt holes Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 61, standard pressure.
PVM098/106 2.50 inch diameter, .500-13 x 1.19 bolt holes 1.00 inch diameter, .375 -16 x .88 bolt holes
Metric Flange 04 ISO 6162 Type I, 350 bar. ISO 6162 Type I, 350 bar. 64mm diameter, M12 x 31 bolt holes 25mm diameter, M10 x 23 bolt holes Inch Flange 02 SAE J518 Code 61, standard pressure. SAE J518 Code 62, high pressure.
PVM131/141 2.50 inch diameter, .500-13 x 1.19 bolt holes 1.25 inch diameter, .500 -13 x 1.00 bolt holes
Metric Flange 04 ISO 6162 Type II, 315 bar. ISO 6162 Type, 400 bar. 64mm diameter, M12 x 31 bolt holes 32mm diameter, M12 x 27 bolt holes
Drain, Load Sensing, and Gauge Ports
Inlet/Outlet Port Option Port Model Series (per model code, page 5) Code Drain Port “F” Load Sensing Port “J” Gauge Port “K” Inch Flange or Tube 01, 03 SAE J514 O-ring, .50’’ O.D. SAE J514 O-ring, .25’’ O.D. SAE J514 O-ring, .25’’ tube. tube. .750-16 UNF 2B thread tube. .4375-20 UNF 2B thread .4375-20 UNF 2B thread
PVM018/020 Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M18 x 1,5 thread M12 x 1,5 thread M12 x 1,5 thread British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E) G 1/2 thread G 1/4 thread G 1/4 thread Inch Flange or Tube 01, 03 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .250’’ O.D. SAE J514 O-ring, .375’’ O.D. tube. tube. .875-14 UNF 2B thread tube. .4375-20 UNF 2B thread .5625-18 UNF 2B thread
PVM045/050 Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring
M22 x 1,5 thread M12 x 1,5 thread M14 x 1,5 thread British Parallel Pipe 05 ISO 228-1:1994 (E) ISO 228-1:1994 (E) ISO 228-1:1994 (E) G 1/2 thread G 1/4 thread G 1/4 thread Inch Flange or Tube 01, 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
PVM057/063 tube. .875-14 UNF 2B thread tube. .5625-18 UNF 2B thread .5625-18 UNF 2B thread
Metric Flange or Tube 03, 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread Inch Flange 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube. PVM074/83 tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B threadPVM098/106 Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread Inch Flange 02 SAE J514 O-ring, .625’’ O.D. SAE J514 O-ring, .375’’ O.D. SAE J514 O-ring, .375’’ O.D. tube.
PVM131/141 tube. .875-14 UNF 2B thread tube. .562-18 UNF 2B thread .5625-18 UNF 2B thread
Metric Flange 04 ISO 6149-1 O-ring ISO 6149-1 O-ring ISO 6149-1 O-ring M22 x 1,5 thread M14 x 1,5 thread M14 x 1,5 thread
116EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Operating Requirements
Inlet Pressure, Case Pressure, and Operating Temperature Requirements
Inlet Pressure Case Pressure Operating TemperatureRated Minimum Maximum Maximum Maximum Maximum Absolute bar, absolute Gauge Continuous Intermittent Peak Rated Intermittent bar (psi) (in. Hg) bar (psi) bar (psi) bar (psi) bar (psi) °C (°F) °C (°F)1,0 (14.5) 0,85 (5) 3,5 (50) 0,5 (7) 2 (30) 3,5 (50) 82 (180) 104 (220)
Hydraulic Fluids
Minimum Viscosity @ Max. Recommended Operating Maximum Viscosity Intermittent Temperature of Viscosity Range at Startup 104°C (220°F) Fluid cSt (SUS) cSt (SUS) cSt (SUS)Use antiwear hydraulic oil, or automotive type crankcase oil (designations SC, SD, SE, 16 to 40 (83 to 187) 1000 (4550) 10 (90) or SF) per SAE J183 FEB80For more information, see Eaton publication 579. For operation on other alternative or environmentally friendly fluids, please contact your Eaton Representative.
Fluid Cleanliness
The M Series pumps are rated in anti-wear petroleum fluids with a contamination level of 20/18/13 (Eaton) or ISO 18/13. Operation in fluids with levels more contaminated than this is not recommended. Fluids other than petroleum, severe service cycles, or temperature extremes are cause for adjustment of these codes. Please contact your Eaton Representative for specific duty cycle recom mendation.
Eaton M Series pumps, as with any variable displacement piston pumps, will operate with apparent satisfaction in fluids up to the rating specified here. Experience has shown, however, that pump and hydraulic system life is not optimized with high fluid contamination levels (high ISO cleanliness codes).
Proper fluid condition is essential for long and satisfac tory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials, and additives for protection against wear of components, elevated viscosity and inclusion of air.
Essential information on the correct methods for treating hydraulic fluid is included in Eaton publication 561 – “Eaton Guide to Systemic Contamination Control” – Available from your local Eaton distributor. In this publication, filtration and cleanliness levels for extending the life of axial piston pumps and other system components are listed. Included is an excellent discussion of the selection of products needed to control fluid condition.
Moment of Inertia (single pump rotating group)
Model Moment of Inertia
N-m (sec2) lbf-in (sec2)
PVM018 0.0012 0.0104
PVM020 0.0012 0.0104
PVM045 0.0036 0.0320
PVM050 0.0034 0.0300
PVM057 0.0052 0.0457
PVM063 0.0051 0.0447
PVM074 0.0078 0.0691
PVM081 0.0073 0.0643
PVM098 0.0132 0.1165
PVM106 0.0123 0.1086
PVM131 0.0213 0.1889
PVM141 0.0210 0.1856
117 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Specifications and PerformanceQuiet version, optimized for 1000-1800 rpm (E) and Higher speed version (M) Alternate fluids guide
Flu
id Ty
pe /
Mode
l Seri
es
Pe
troleu
m Ba
se
Pe
troleu
m Ba
se
Mo
tor O
il
Unive
rsal
Au
toma
tic
Mil S
pec F
luids
En
viron
ment
ally A
ccep
table
Fluids
Fir
e Res
istan
t Flui
ds
Spec
ialty
Fluids
Fo
od G
rade
Fluid
ZD
DP
Zin
c Free
Tr
actor
Tr
ansm
ission
Flu
id
Vege
table
Base
Synth
etic B
ase
Synth
etic B
ase
Wate
r Con
tainin
g Cu
tting F
luids
H1 - a
pprov
ed
AW
(HM)
AW (H
M)
UTTO
ATF
HETG
HEES
Ph
osph
ate es
ter
HFDR
Po
lyeste
r - HF
DU
Polye
ther p
olyol
- HF
DU
Wate
r Glyc
ol -
HFC
Invert
Emuls
ion -
HFB
1 Mo
del s
eries
Quie
t ver
sion “
E” @
18
00 R
PM U
nless
Not
ed
PV
M 18
, PVM
45, P
VM 57
, PVM
74,
PVM
98
40
60 P
SI
NR
3625
PSI
**
36
25 P
SI **
3625
PSI
**
NR
3625
PSI
**
3625
PSI
1800
RP
M
3300
PSI
**
33
00 P
SI **
NR
25
00 P
SI **
2250
PSI
**
NR
3625
PSI
**
PVM
20, P
VM 50
, PVM
63, P
VM 81
, PV
M 10
6
33
35 PS
I
NR
32
50 PS
I **
32
50 PS
I **
32
50 PS
I **
NR
3250
PSI *
* 32
50 PS
I 1
800
RPM
30
00 P
SI **
3000
PSI
**
NR
2250
PSI
**
20
00 P
SI **
NR
32
50 P
SI *
*
PVM
131
40
60 PS
I
NR
36
25 PS
I **
36
25 PS
I **
36
25 PS
I **
NR
3625
PSI **
36
25 P
SI
150
0 RP
M 33
00 P
SI **
150
0 rpm
33
00PS
I ** 1
500
rpm
NR
25
00 P
SI **
15
00 rp
m 22
50 P
SI **
150
0 rpm
NR
3625
PSI
**
PVM
141
33
35 P
SI
NR
3250
PSI
**
32
50 P
SI **
3250
PSI
**
NR
3250
PSI
**
3250
PSI
1
500
RPM
3000
PSI
** 1
500
rpm
3000
PSI
**
1500
rpm
NR
22
50 P
SI **
15
00 rp
m 20
00 P
SI **
150
0 rpm
NR
3250
PSI
**
2 Mo
del S
eries
High
er Sp
eed
Vers
ion (M
)
PVM
18
4060
PSI
280
0 RP
M
NR
3625
PSI **
28
00 RP
M 36
25 PS
I **
2800
RPM
3625
PSI **
28
00 RP
M
NR
36
25 P
SI **
28
00 R
PM
3625
PSI
18
00
RPM
3300
PSI
**
1800
RPM
33
00 P
SI **
18
00 R
PM
NR
25
00 P
SI **
18
00 R
PM
2250
PSI
**
1800
RPM
NR
NR
PVM
20
3335
PSI
2
800
RPM
NR
32
50 PS
I ** 28
00
RPM
3250
PSI **
2800
RP
M 32
50 PS
I ** 28
00
RPM
NR
32
50 PS
I ** 28
00
RPM
3250
PSI
180
0 RP
M 30
00 PS
I **
1800
RPM
30
00 PS
I **
1800
RPM
NR
22
50 P
SI **
18
00 R
PM
2000
PSI
**
1800
RPM
NR
NR
PVM
45
4060
PSI
2
600
RPM
NR
36
25 PS
I **
2600
RPM
36
25 PS
I **
2600
RPM
36
25 PS
I **
2600
RPM
NR
36
25 P
SI **
26
00 R
PM
3625
PSI
1
800
RPM
3300
PSI
**
1800
RPM
33
00 P
SI **
18
00 R
PM
NR
25
00 P
SI **
18
00 R
PM
2250
PSI
**
1800
RPM
NR
NR
PVM
50
3335
PSI
260
0 RP
M
NR
3250
PSI
** 2
600
RPM
3250
PSI
** 2
600
RPM
3250
PSI
** 2
600
RPM
NR
32
50 PS
I ** 26
00
RPM
3250
PSI
180
0 RP
M 30
00 PS
I **
1800
RPM
30
00 PS
I **
1800
RPM
NR
22
50 P
SI **
18
00 RP
M 20
00 P
SI **
18
00 RP
M
NR
NR
PVM
57
4060
PSI
2
500
RPM
NR
36
25 PS
I **
2500
RPM
36
25 PS
I **
2500
RPM
36
25 PS
I **
2500
RPM
NR
36
25 P
SI **
25
00 RP
M 36
25 P
SI
180
0 RP
M 33
00 P
SI
180
0 RP
M 33
00 P
SI
1800
RPM
NR
25
00 P
SI **
18
00 R
PM
2250
PSI
**
1800
RPM
NR
NR
PVM
63
3335
PSI
250
0 RP
M
NR
32
50 P
SI **
250
0 RP
M 32
50 P
SI **
250
0 RP
M 32
50 P
SI **
250
0 RP
M
NR
32
50 P
SI **
250
0 RP
M 32
50 P
SI
180
0 RP
M 30
00 P
SI **
18
00 R
PM
3000
PSI
**
1800
RPM
NR
22
50 P
SI **
18
00 RP
M 20
00 P
SI **
18
00 RP
M
NR
NR
PVM
74
4060
PSI
2
400
RPM
NR
36
25 PS
I **
2400
RPM
36
25 PS
I **
2400
RPM
36
25 PS
I **
2400
RPM
NR
36
25 P
SI **
24
00 RP
M 36
25 P
SI
180
0 RP
M 33
00 P
SI **
180
0 RP
M 33
00 P
SI **
18
00 RP
M
NR
25
00 P
SI **
18
00 R
PM
2250
PSI
**
1800
RPM
NR
NR
PVM
81
3335
PSI
240
0 RP
M
NR
32
50 P
SI **
240
0 RP
M 32
50 P
SI **
240
0 RP
M 32
50 P
SI **
240
0 RP
M
NR
32
50 P
SI **
240
0 RP
M 32
50 P
SI
180
0 RP
M 30
00 P
SI **
18
00 R
PM
3000
PSI
**
1800
RPM
NR
22
50 PS
I **
1800
RPM
2000
PSI **
18
00 RP
M
NR
NR
PVM
98
4060
PSI
2
200
RPM
NR
36
25 P
SI **
220
0 RP
M 36
25 P
SI **
220
0 RP
M 36
25 P
SI **
220
0 RP
M
NR
36
25 P
SI **
220
0 RP
M 36
25 P
SI
1800
RP
M 33
00 P
SI **
180
0 RP
M 33
00 P
SI **
18
00 RP
M
NR
25
00 P
SI **
18
00 R
PM
2250
PSI
**
1800
RPM
NR
NR
PVM
106
3335
PSI
220
0 RP
M
NR
32
50 P
SI **
220
0 RP
M 32
50 P
SI **
220
0 RP
M 32
50 P
SI **
220
0 RP
M
NR
32
50 P
SI **
220
0 RP
M 32
50 P
SI
180
0 RP
M 30
00 P
SI **
180
0 RP
M 30
00 P
SI **
18
00 R
PM
NR (P
SI)
180
0 RP
M 22
50 P
SI **
18
00 R
PM
20
00 PS
I **
NR
NR
PVM
131
4060
PSI
200
0 RP
M
NR
36
25 P
SI **
200
0 RP
M 36
25 P
SI **
200
0 RP
M 36
25 P
SI **
200
0 RP
M
NR
36
25 P
SI **
200
0 RP
M 36
25 P
SI
150
0 RP
M 33
00 P
SI **
180
0 RP
M 33
00 P
SI **
18
00 R
PM
NR
25
00 P
SI **
15
00 R
PM
2250
PSI
1
500
RPM
NR
NR
PVM
141
3335
PSI
2
000
RPM
NR
32
50 P
SI **
200
0 RP
M 32
50 P
SI **
200
0 RP
M 32
50 P
SI **
200
0 RP
M
NR
32
50 P
SI **
200
0 RP
M 32
50 P
SI
150
0 RP
M 30
00 P
SI **
180
0 RP
M 30
00 P
SI**
1800
RP
M
NR
22
50 P
SI **
15
00 R
PM
2000
PSI
** 1
500
RPM
NR
NR
Spec
ifica
tions
and
Per
form
ance
118 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Installation and Start-up
Warning: Care should be taken that mechanical and hydraulic resonances are avoided in the application of the pump. Such resonances can seriously compromise the life and/or safe operation of the pump.
Drive Data
Mounting attitude can be either horizontal or vertical, using the appropriate case drain ports to ensure that the case remains full of fluid at all times. Consult your local Eaton Representative if a different arrangement is required.
In those cases where geometric tolerances of mounting are critical, or where specific tolerance ranges are required and not specified, consult Eaton Engineering for specific limits.
Direction of shaft rotation, viewed from the prime mover end, must be as indicated in the model designation on the pump – either right hand (clockwise) or left hand (counterclockwise).
Direct coaxial drive through a flexible coupling is recommended. If drives imposing radial shaft loads are considered, please consult your Eaton Representative.
Start-up Procedure
Make sure the reservoir and circuit are clean and free of dirt/debris prior to filling with hydraulic fluid.
Fill the reservoir with filtered oil and fill to a level sufficient enough to prevent vortexing at the suction connection to pump inlet. It is good practice to clean the system by flushing and filtering, using an external slave pump.
Caution: Before the pump is started, fill the case through the uppermost drain port with hydraulic fluid of the type to be used. The case drain line must be connected directly to the reservoir and must terminate below the oil level.
Once the pump is started, it should prime within a few seconds. If the pump does not prime, check to make sure that there are no restrictions between the reservoir and the inlet to the pump, that the pump is being rotated in the proper direction, and that there are no air leaks in the inlet line and connections. Also check to make sure that trapped air can escape at the pump outlet.
After the pump is primed, tighten the loose outlet con-nections, then operate for five to ten minutes (unloaded) to remove all trapped air from the circuit.
If the reservoir has a sight gage, make sure the fluid is clear – not milky.
119 EATON Industrial Variable Displacement Piston Pumps V-PUPI-TM007-E2 April 2015
Operation and Installation
Power Control/Torque Limiter
Description
PVM series piston pump with Power Control consists of, A)pump with modified pressure and flow compensator and B) Power Control subassembly installed.
Power Control Operation
The Power Control Subassembly consists of a poppet type valve guided by a specially designed control piston having a unique profile. The cracking pressure of the poppet valve, being guided by the profile on the control piston, is dependent on the actual displacement of the pump. For lower displacement the cracking pressure is high. As displacement is increased, the cracking pressure is reduced according to the profile on the control piston. The poppet type valve gets pressure signal either from the modified load sense port (for Pressure Flow Compensated) or the pump outlet pressure (for Pressure Compensated). The power control subassembly regulates this pressure based on the displacement. This regulated pressure is internally fed back to the control piston chamber, which compensates by adjusting the pump displacement appropriately. This results in achieving the desired control of constant nput power.
Power Control Adjustment
To adjust the control power setting, power measurement devices are required. For Input power, motor torque and speed need to be measured. For output power, devices for pump pressure and flow measurements are required. The pump comes with factory set power setting as indicated by pos. 22 23 of pump model code. It is recommended not to change this setting unless absolutely necessary. The setting can be changed by loosening the lock nut on top of the control subassembly and turning the adjust ment screw with help of allen key. Rotating adjustment screw clockwise increases the power setting while rotating it anticlockwise reduces it. After adjustment as required ensure that the locknut is tightened properly.
Pump with PFC
Power control S/A
Lock nut
Adjusting screw
© 2015 EatonAll Rights Reserved Printed in USADocument No. V-PUPI-TM007-E2April 2015
EatonHydraulics Group USA14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952-937-9800Fax: 952-294-7722www.eaton.com/hydraulics
EatonHydraulics Group EuropeRoute de la Longeraie 71110 MorgesSwitzerlandTel: +41 (0) 21 811 4600Fax: +41 (0) 21 811 4601
EatonHydraulics Group Asia PacificEaton BuildingNo.7 Lane 280 Linhong RoadChangning District,Shanghai 200335ChinaTel: (+86 21) 5200 0099Fax: (+86 21) 2230 7240