WWW.GENERGYCABLE.COM | 800-308-1330
TM
INDUSTRIAL
800-308-1330 | WWW.GENERGYCABLE.COM
INDUSTRIAL CATALOG INDUSTRIAL CATALOG
Flexible.GenErgy was born from a wire and cable manufacturer with over a half a century of experience. The result is the most comprehensive and capable cable offering to the industry.
Vertically aligned with complete access to a fully-integrated copper and compound facility, GenErgy is strategically positioned to offer a competitive and adaptive cable assembly solution unmatched in the industrial market.
800-308-1330 | WWW.GENERGYCABLE.COM WWW.GENERGYCABLE.COM | 800-308-1330
INDUSTRIAL CATALOG INDUSTRIAL CATALOG
Assembled Cable ........................................................................................................................... 2Type W Assemblies and Pigtails ..............................................................................................................................2Type PPE Assemblies and Pigtails ..........................................................................................................................350A Twist-Lock Extensions and Tie-Ins .................................................................................................................4SC (Entertainment Cable) Feeder Cable Assemblies .......................................................................................5SC (Entertainment Cable) Tie-In Sets and Pigtails ............................................................................................65-Wire Banded Cam Lock Cable Extensions and Pigtails ..............................................................................7Quad Box Stringers and Extensions ......................................................................................................................8Edison Extensions/5-15 Straight Blade Extensions .........................................................................................920A and 30A Locking Extensions ........................................................................................................................ 10Pin & Sleeve Extensions .......................................................................................................................................... 11Medium Voltage ..................................................................................................................................................12-13
Cut to Length Cable ..................................................................................................................... 14Type SJOOW 300V Flexible Power Cord............................................................................................................ 14Type SOOW 600V Flexible Power Cord .......................................................................................................15-16Type SC 600V Entertainment Cable .................................................................................................................. 17Type PPE 2000V Portable Power Cable ............................................................................................................. 18Type W 2000V Power Cable ................................................................................................................................... 19Type W Multi-Conductor 2/C ................................................................................................................................ 20Type W Multi-Conductor 3/C ................................................................................................................................ 21Type W Multi-Conductor 4/C ................................................................................................................................ 22Type W Multi-Conductor 5/C ................................................................................................................................ 23Type DLO (Diesel Locomotive Cable) ................................................................................................................ 24Medium Voltage MV-105 5kV/8kV ...................................................................................................................... 25Medium Voltage MV-105 15kV ............................................................................................................................. 26Jumper Cable 5kV/8kV ............................................................................................................................................ 27Type SH 5kV Medium Voltage Power Cable .................................................................................................... 28Type SH 15kV Medium Voltage Power Cable .................................................................................................. 29
Cable Accessories ........................................................................................................................ 30Power Distribution Boxes .................................................................................................................................30-31Connectors: Turnarounds, T’s, 3-Fers .................................................................................................................. 32Connectors: Series 15 - 17 Cam Locks, Covers, Protective Caps ............................................................... 33Connectors: Lugs, Splices, Shoo-Pins, Center and Offset Pins, Twist-Locks ......................................... 34Cable Carrying Straps .............................................................................................................................................. 35Industrial Strength Cable Ramps ........................................................................................................................ 35Heavy-Duty Collapsible Containers ................................................................................................................... 36
Table of Contents
2 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
GENFLEX™ TYPE W 2000V PORTABLE POWER CABLE ASSEMBLIES GENFLEX™ TYPE PPE 2000V PORTABLE POWER CABLE ASSEMBLIES
FEATURES• UL Listed Portable Power Cable made
from annealed no. 30 gauge bare copper stranding
• Flexible EPR/CPE single conductor portable power cable
• Reinforced strength • Incredible resistance to impact and
abrasion• Water, flame, ozone, sunlight, grease,
weather, and chemical resistant• Operating temperatures range from
-40°C to 90°C dry
AVAILABLE OPTIONS• Multi-Conductor Type W cable• Custom cable print• Sequentially marked• Made-to-order lengths• Heat shrink logo ID• All standard cam-lock colors: Black,
White, Brown, Yellow, Red, Orange, Green, and Blue
APPLICATIONSFor heavy-duty temporary and permanent power for portable generators, grounding, power extension, mining and oil drilling
CONSTRUCTIONConductors – Extra flexible strand copper, ASTM B-172 and ICEA S-75-381Insulation – Ethylene-propylene rubber (EPR), UL 1072Jacket – Black heavy-duty CPE thermoset compound, ICEA S-75-381 sec 3.22Durable Jacket EPR (ethylene-propylene rubber) with black heavy-duty CPE thermoset compound
Part Number AWG
Ampacity* 40ºC
Ambient Temp.
Description
AW02BXXXAMBFB #2 190 #2 Type W with Black Male & Female CAM Connectors
W20BXXXAMBFB 2/0 300 2/0 Type W with Black Male & Female CAM Connectors
W40BXXXAMBFB 4/0 405 4/0 Type W with Black Male & Female CAM Connectors
* Ampacity – Free air measure; Based on continuous duty at 90°C conductor temperature no.Note: XXX in part number equals desired length: 025, 050, 075, 100
GENFLEX™ TYPE W ASSEMBLIES
GENFLEX™ TYPE W PIGTAILSPart Number Description
W40B006PMB 4/0 Type W 6 ft. Pigtail with Black Male CAM Connector and Bare
W40B006PFB 4/0 Type W 6 ft. Pigtail with Black Female CAM Connector and Bare
W40B003PMBH 4/0 Type W 3 ft. Pigtail with Black Male CAM Connector and Bare
W40B003PFBH 4/0 Type W 3 ft. Pigtail with Black Female CAM Connector and Bare
Termination Options Available: Lug, Center Pin, Offset Pin, Shoo-Pin, Barrel Pin
Rated up to 2000VUL, CSA, and MSHA approved
2 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 3
GENFLEX™ TYPE W 2000V PORTABLE POWER CABLE ASSEMBLIES GENFLEX™ TYPE PPE 2000V PORTABLE POWER CABLE ASSEMBLIES
APPLICATIONSTemporary and permanent power for portable generators, AC, grounding, power extension, shore power, mining, oil drilling
Rated up to 2000VUL and MSHA approved
CONSTRUCTIONConductors – Highly flexible stranded No. 30 bare copperSeparator – High strength fiber braid separator between the conductor and insulationInsulation – High grade RoHS compliant Thermoplastic Elastomer (TPE)Jacket – Black heavy-duty RoHS compliant Thermoplastic Elastomer (TPE)
Part Number AWG
Ampacity* 40ºC
Ambient Temp.
Description
A
G02BXXXAMBFB #2 190 #2 Type PPE with Black Male & Female CAM Connectors
G20BXXXAMBFB 2/0 300 2/0 Type PPE with Black Male & Female CAM Connectors
G40BXXXAMBFB 4/0 405 4/0 Type PPE with Black Male & Female CAM Connectors
* Ampacity – Free air measure; Based on continuous duty at 90°C conductor temperature no.
Note: XXX in part number equals desired length: 025, 050, 075, 100
GENFLEX™ TYPE PPE ASSEMBLIES
GENFLEX™ TYPE PPE PIGTAILSPart Number Description
G40B006PMB 4/0 Type PPE 6' Pigtail with Black Male CAM Connector and Bare
G40B006PFB 4/0 Type PPE 6' Pigtail with Black Female CAM Connector and Bare
G40B003PMB 4/0 Type PPE 3' Pigtail with Black Male CAM Connector and Bare
G40B003PFB 4/0 Type PPE 3' Pigtail with Black Female CAM Connector and Bare
Termination Options Available: Lug, Center Pin, Offset Pin, Shoo-Pin, Barrel Pin
FEATURES• UL Listed Portable Power Cable made from
annealed no. 30 gauge bare copper stranding• Durable TPE jacket and insulator for maximum
flexibility• UL and MSHA approved• National Electric Code Article 400• Can be used in Type W applications• Incredible resistance to impact and abrasion• Water, flame, ozone, sunlight, grease, weather,
and chemical resistant• Operating temperatures range from
-40°C to 90°C dry
AVAILABLE OPTIONS• Custom cable print• Sequentially marked• Made-to-order lengths• Heat shrink logo ID• Available in black, red, blue, white, green,
brown, orange, and yellow jacketed cable• All standard cam-lock colors: Black, White,
Brown, Yellow, Red, Orange, Green, and Blue
4 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
50A TWIST-LOCK EXTENSIONS AND TIE-INS GENFLEX™ TYPE SC FEEDER CABLE ASSEMBLIES
APPLICATIONSUsed to provide temporary power for disaster recovery and industrial applications
FEATURES• Also known as California style cords and
6/4 spider box cables • Assembled with 6/4 cable and black and
white 50A Non-NEMA line of industrial-grade locking blade connectors
• Great impact, sunlight, and chemical resistance
• Withstands rough use• Connectors feature one-piece construction
for maximum conductivity• Brass mounting system for a safer
resistance ground path
AVAILABLE OPTIONS• Custom lengths• Custom cable identification
Part Number AWG No. ofConductors
Stranding/ Diameter
Nominal Insulation Thickness
Nominal Jacket
ThicknessNominal
O.D.Approx.Weight
lbs./ 1000 ft.
Ampacity*30ºC
Ambient Temp.
in. mm in. mm in. mm A
SOOW6-4 6 4 184/0.0117 0.060 1.52 0.140 3.56 1.05 26.7 785 45.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
Part Number Male Connector Female Connector Cable Lengths
P064BXXXACSMFNon-NEMA, 125/250V AC, 3P/4W, Black & White Locking Connector,
Industrial Grade, Grounding, California-Style (CS)
Non-NEMA, 125/250V AC, 3P/4W, Black & White Locking Connector,
Industrial Grade, Grounding, California-Style (CS)
6/4 25', 50', 75', 100'
P064B005PCSMBNon-NEMA, 125/250V AC, 3P/4W, Black & White Locking Connector,
Industrial Grade, Grounding, California-Style (CS)
Bare 6/4 5'
P064B005PCSFB BareNon-NEMA, 125/250V AC, 3P/4W, Black & White Locking Connector,
Industrial Grade, Grounding, California-Style (CS)
6/4 5'
Note: XXX in part number equals desired length: 005, 010, 025, 050, 075, 100
EXTENSIONS AND TIE-INS
SOOW CABLE
4 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 5
50A TWIST-LOCK EXTENSIONS AND TIE-INS GENFLEX™ TYPE SC FEEDER CABLE ASSEMBLIES
APPLICATIONSUsed for portable power and lighting events and applications in the entertainment industry including motion picture, television, theaters, stages, concerts, and conventions
FEATURES• UL and c(UL) Listed GenFlex™ Type SC cable
made from annealed no. 30 gauge bare copper stranding
• Durable CPE insulation• Meets/exceeds flame test requirements of
UL and c(UL)• Resistant to abrasion, acids, heat, flame,
chemicals, sunlight, water, and ozone• Excellent flexibility and durability• Standard lengths: 25', 50', 75', 100'
• Cable carrying strap included with 25' and 50' lengths
AVAILABLE OPTIONS• 5-wire banded sets or pigtails • Custom lengths• Custom cable identification• 6 AWG green jacketed cable • All standard cam-lock colors: Black, White, Brown,
Yellow, Red, Orange, Green, and Blue
Rating AWG Length Connectors Description Part Number190A, 600VAC #2 25', 50', 75', 100' 16 Series Cams #2 SC 25' BLK M&F BLK Cams S02BXXXAMBFB
300A, 600VAC 2/0 25', 50', 75', 100' 16 Series Cams 2/0 SC 25' BLK M&F BLK Cams S20BXXXAMBFB
405A, 600VAC 4/0 25', 50', 75', 100' 16 Series Cams 4/0 SC 25' BLK M&F BLK Cams S40BXXXAMBFB
Note: XXX in part number equals desired length: 025, 050, 075, 100
PowerConductor
Size
PowerConductorStranding
Nominal JacketThickness Nominal O.D. Approx. Weight Ampacity*
AWG No. ofWires in. mm in. mm lbs./
1000 ft. kgs/km A
6 AWG 258/30 0.095 2.41 0.371 9.4 131 195 105
4 AWG 410/30 0.095 2.41 0.430 10.9 189 282 140
2 AWG 649/30 0.106 2.69 0.509 12.9 285 424 190
1 AWG 815/30 0.136 3.45 0.611 15.5 379 564 220
1/0 AWG 1032/30 0.136 3.45 0.672 17.1 463 689 260
2/0 AWG 1287/30 0.136 3.45 0.697 17.1 549 816 300
3/0 AWG 1622/30 0.136 3.45 0.777 19.7 674 1003 350
4/0 AWG 2052/30 0.136 3.45 0.803 20.4 814 1212 405
* Ampacities are based on single conductor in free air, 30°C ambient air temperature 90°C conductor operating temperature per Table 400-5 (B) of the 2008 NEC
FEEDER ASSEMBLIES
GENFLEX™ TYPE SC CABLE
6 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
GENFLEX™ TYPE SC TIE-IN SETS AND PIGTAILS GENFLEX™ BANDED CAM LOCK EXTENSIONS AND BANDED PIGTAILS
FEATURES• Assembled with UL and c(UL) Listed GenFlex™
Type SC cable made from annealed no. 30 gauge bare copper stranding
• Banded every 24" with heavy-duty glued shrink• Durable CPE insulation• Meets/exceeds flame test
requirements of UL and c(UL)• Resistant to sunlight, water, ozone, abrasion,
acids, heat, flame, and chemicals• Excellent flexibility and durability• Standard lengths: 25' and 50'
AVAILABLE OPTIONS• Custom lengths• Custom cable identification• All standard cam-lock colors:
Black, White, Brown, Yellow, Red, Orange,Green, and Blue
APPLICATIONSPortable power and lighting applications in the entertainment industry including movie production, concerts, and convention center
Rating Male End Female End Cable Part Number
400A, 600VAC 16 Series Cams Bare 4/0 SC S40BXXXMB
400A, 600VAC Bare 16 Series Cams 4/0 SC S40BXXXFB
300A, 600VAC 16 Series Cams Bare 2/0 SC S20BXXXMB
300A, 600VAC Bare 16 Series Cams 2/0 SC S20BXXXFB
190A, 600VAC 16 Series Cams Bare #2 SC S02BXXXMB
190A, 600VAC Bare 16 Series Cams #2 SC S02BXXXFB
NOTE: Pigtails available with bare end, lug, or pin.
Rating Male End Female End Cable Part Number
400A, 600VAC Bare (5) 16 Series Cams (Black, White, Red, Blue, Green) 4/0 SC S40BXXXFB
300A, 600VAC Bare (5) 16 Series Cams (Black, White, Red, Blue, Green) 2/0 SC S20BXXXFB
190A, 600VAC Bare (5) 16 Series Cams (Black, White, Red, Blue, Green) #2 SC S02BXXXFB
NOTE: Reverse ground or reverse ground/neutral available.
TIE-IN SETS
PIGTAILS
6 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 7
GENFLEX™ TYPE SC TIE-IN SETS AND PIGTAILS GENFLEX™ BANDED CAM LOCK EXTENSIONS AND BANDED PIGTAILS
APPLICATIONSPortable power and lighting applications in the entertainment industry: motion picture, television, stage and event locations. Light industrial uses include temporary power and generator connections
FEATURES• Highly flexible annealed 30 gauge bare
copper conductor insulated with a durable high grade RoHS compliant CPE
• Banded every 24' with heavy-duty glued shrink
• Meets/exceeds flame test requirements of UL and c(UL)
• Resistant to sunlight, water, ozone, abrasion, acids, heat, flame, and chemicals
AVAILABLE OPTIONS• Reversed ground and neutral• #6 green ground • Custom lengths• Custom cable identification
GENFLEX™ SC BANDED EXTENSIONSGauge Male End Female End Description Part Number
#2 (5) 16 Series Cams (5) 16 Series Cams Stage Cable (SC) S02BXXXBANDMFC
2/0 (5) 16 Series Cams (5) 16 Series Cams Stage Cable (SC) S20BXXXBANDMFC
Note: XXX in part number equals desired length: 025, 050
Rating Gauge Male End Female End Part Number
100A, 600VAC #2 Bare (5) 16 Series Cams (Black, White, Red, Blue, Green) S02BXXXBAND5MB
200A, 600VAC 2/0 Bare (5) 16 Series Cams (Black, White, Red, Blue, Green) S20BXXXBAND5MB
100A, 600VAC #2 (5) 16 Series Cams (Black, White, Red, Blue, Green) Bare S02BXXXBAND5FB
200A, 600VAC 2/0 (5) 16 Series Cams (Black, White, Red, Blue, Green) Bare S20BXXXBAND5FB
Note: XXX in part number equals desired length: 005, 010, 015, 020, etc.
GENFLEX™ SC BANDED PIGTAILS
TM
8 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
QUAD BOX STRINGERS AND EXTENSIONS EDISON EXTENSIONS/5-15 STRAIGHT BLADE EXTENSIONS
APPLICATIONSAssembled with black SOOW cable, Wetguard connectors, and durable high quality yellow quad boxes
FEATURES• Molded Santoprene TPV housing
for harsh conditions
• Non-metallic construction provides protection
• Industrial grade
• Resistant to chemicals and fatigue
• Great impact resistance
• Spring loaded flip lids
• Wetguard connectors are water and corrosion resistant
– Acid and solvent resistant– Heavy-duty one-piece contacts– Innovative strain relief system
AVAILABLE OPTIONS• Non-GFCI receptacles
• Custom lengths and cable identification
Part Number Input/Output Feed Through Cable Length
QS105B050AMBFB NEMA L21-30 30A, 4P5W Locking plug/connector 120/208V
NEMA 5-20, 20 A, 2P3W 125/208 VAC GFCI
10/5 SOOW
50' (15'-10'-10'-15')
QS125B050AMBFB NEMA L21-20 20A, 4P5W Locking plug/connector 120/208V
NEMA 5-20, 20 A, 2P3W 125/208 VAC GFCI
12/5 SOOW
50' (15'-10'-10'-15')
QUAD BOX STRINGERS
Part Number Rating Connector CableP105BXXXL2130-WG 30A, 120 VAC L21-30 Locking 10/5 SOOWP125BXXXL2120-WG 20A, 120 VAC L21-20 Locking 12/5 SOOW
Note: XXX in part number equals desired length: 005, 010, 0150, 025, 050, 075, 100
QUAD BOX EXTENSIONS
8 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 9
QUAD BOX STRINGERS AND EXTENSIONS EDISON EXTENSIONS/5-15 STRAIGHT BLADE EXTENSIONS
APPLICATIONSUsed for supplying lighter-duty, general-purpose electrical devices in stage and theater productions, studio and event lighting, and in many other entertainment and industrial applications
FEATURES• Built to NEMA standards
• Indoor and outdoor UL listing/ CSA certified
• MSHA approved
• Factory-tested
• Oil, water, abrasion, and UV resistant outer jacket and insulation
• Edison plug and connectors
• 3-wire 15A assemblies
AVAILABLE OPTIONS• Custom lengths
• Custom cable identificationPart Number Rating Cable NEMA
P123BJXXX515 15A, 125 VAC 12/3 SJOOW 5-15 straight blade
P123BXXXE515 15A, 125 VAC 12/3 SOOW 5-15 straight blade
STRAIGHT BLADE/EDISON EXTENSIONS
Part Number AWG No. ofConductors
Stranding/ Diameter
Nominal Insulation Thickness
Nominal Jacket
ThicknessNominal O.D.
Approx.Weight
lbs./ 1000 ft.
Ampacity*30ºC
Ambient Temp.in. mm in. mm in. mm A
SJOOW12-3 12 3 65/30 0.030 0.76 0.045 1.14 0.43 10.9 131 25.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
SJOOW 300V CABLE
Part Number AWG No. ofConductors
Stranding/ Diameter
Nominal Insulation Thickness
Nominal Jacket
ThicknessNominal O.D.
Approx.Weight
lbs./ 1000 ft.
Ampacity*30ºC
Ambient Temp.in. mm in. mm in. mm A
SOOW12-3 12 3 65/30 0.045 1.14 0.095 2.41 0.59 15.2 217 25.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
SOOW 600V CABLE
10 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
20A AND 30A LOCKING EXTENSIONS PIN & SLEEVE EXTENSIONS
APPLICATIONS20A and 30A extra hard usage cords are built with plugs and connectors resistant to chemicals, and environmental concerns so you can use indoors or outdoors
FEATURES• Produced with SOOW cord
• Factory-tested
• Heavy-duty UL and CSA cable
• Excellent oil, water, abrasion, and UV resistance
AVAILABLE OPTIONS• Custom lengths
• Heat shrink logo identification
• SJOOW
NEMA CONFIGURATIONS• L5 – 125V 2P/3W
• L6 – 250V 2P/3W
• L14 – 125/250V 3P/4W
• L21 – 120/208V 4P/5W
• L22 – 277/480V 4P/5W
RATING CABLE CONNECTOR PART NUMBER20A, 125V 12/3 SOOW L5-20 P123BXXXL52020A, 250V 12/3 SOOW L6-20 P123BXXXL62020A, 125/250V 12/4 SOOW L14-20 P124BXXXL142020A, 120/208V 10/5 SOOW L21-20 P105BXXXL212020A, 277/480V 10/5 SOOW L22-20 P105BXXXL2220
Note: XXX in part number equals desired length: 025, 050, 075, 100, etc.
20A LOCKING EXTENSIONS
RATING CABLE CONNECTOR PART NUMBER20A, 125V 10/3 SOOW L5-30 P103BXXXL53020A, 250V 10/3 SOOW L6-30 P103BXXXL63020A, 125/250V 10/4 SOOW L14-30 P104BXXXL143020A, 120/208V 10/5 SOOW L21-30 P105BXXXL213020A, 277/480V 10/5 SOOW L22-30 P105BXXXL2230
Note: XXX in part number equals desired length: 025, 050, 075, 100, etc.
30A LOCKING EXTENSIONS
PARTNUMBER AWG NO. OF
CONDUCTORSSTRANDING/ DIAMETER
NOMINAL INSULATION THICKNESS
NOMINAL JACKET
THICKNESSNOMINAL
O.D.APPROX.WEIGHT
LBS./ 1000 FT.
AMPACITY*30ºC AMBIENT
TEMP.
IN. MM IN. MM IN. MM A
SOOW12-3SOOW12-4SOOW12-5
12345
65/30 0.045 1.14 0.095 2.410.590.640.76
15.216.517.8
217261319
25.020.016.0
SOOW10-3SOOW10-4SOOW10-5
10345
104/30 0.045 1.14 0.095 2.410.650.700.76
16.517.819.3
281336409
30.025.020.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
SOOW CABLE
10 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 11
20A AND 30A LOCKING EXTENSIONS PIN & SLEEVE EXTENSIONS
APPLICATIONSSafe, reliable power for any type of heavy-duty temporary or permanent equipment. Use to supply power to welders, gen-sets, compressors, conveyors, portable tools, and portable lighting equipment.
Rating Cable Connectors Part Number
30A, 4 Pole, 5-Wire, 120/208 VAC, 3 Phase 10/5 Type SOOW IEC 60309
Watertight Pin & Sleeve P105BXXXA60309
60A, 4 Pole, 5-Wire, 120/208 VAC, 3 Phase 6/5 Type SOOW IEC 60309
Watertight Pin & Sleeve P065BXXXA60309
100A, 4 Pole, 5-Wire, 120/208 VAC, 3 Phase 4/5 Type W IEC 60309
Watertight Pin & Sleeve P045BXXXA60309
30A, 4 Pole, 4-Wire, 600 VAC, 250V 10/5 Type SOOW NEMA 4X
Powermate Pin & Sleeve P105BXXXANEMA4X
60A, 4 Pole, 4-Wire, 600 VAC, 250V 6/5 Type SOOW NEMA 4X
Powermate Pin & Sleeve P065BXXXANEMA4X
100A, 4 Pole, 4-Wire, 600 VAC, 250V 4/4 Type W NEMA 4X
Powermate Pin & Sleeve P044BXXXANEMA4X
Note: XXX in part number equals desired length: 005, 010, 025, 050, 075, 100
PIN & SLEEVE EXTENSIONS
FEATURES• Assembled with 30A, 60A, and 100A plug and
connectors and Type W or Type SOOW cable
• Corrosion and impact resistance
• Waterproof seals to resist harsh weather and rough working conditions
• Secure electrical connections and superior performance in high-abuse environments
• Standard lengths: 25' and 50'
AVAILABLE OPTIONS• Tie-ins
• Custom lengths and cable identification
• Additional IEC 60309 watertight connectors
• Arktite® cast aluminum and non-metallic plugs, receptacles and connectors
12 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
MEDIUM VOLTAGE ASSEMBLIES MEDIUM VOLTAGE ASSEMBLIES
APPLICATIONSType SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent power including substations, switchgear, transformers, and utility applications.
FEATURES• HiPot testing report provided for each assembly
• Assemblies are HiPot tested at NETA recommended DC values
• Excellent flexibility
• Highly resistant to ozone, sun, weather and flame
• Rated and flexible at –40ºC
• Excellent impact and abrasion resistant
• Oil and heat resistant
AVAILABLE OPTIONS• 5kV, 15kV, and 35kV
• MV-105 Cable
• Lug, Loadbreak Elbow, and Deadbreak Elbow Terminations
• Heat Shrink Logo ID
• Custom lengths
12 | ASSEMBLED CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM ASSEMBLED CABLE | 13
MEDIUM VOLTAGE ASSEMBLIES MEDIUM VOLTAGE ASSEMBLIES
Part Number AWG Termination A Termination B Description
SH15KV40BXXXACSCS 4/0 2 Hole CU Lug (CS) 2 Hole CU Lug (CS) 4/0 Type SH 15kV with Lugs on Both Terminations
SH15KV40BXXXACSLE 4/0 2 Hole CU Lug (CS) 200A Loadbreak Elbow 4/0 Type SH 15kV with Lug and Loadbreak Elbow
SH15KV40BXXXACSDE 4/0 2 Hole CU Lug (CS) 600A Deadbreak Elbow 4/0 Type SH 15kV with Lug and Deadbreak Elbow
SH15KV40BXXXADEDE 4/0 600A Deadbreak Elbow 600A Deadbreak Elbow 4/0 Type SH 15kV Deadbreak Elbows on Both Terminations
Note: XXX in part number equals desired length: 025, 050, 075, 100, 200, 300
MEDIUM VOLTAGE ASSEMBLIES
Part Number AWG Termination A Termination B Description
SH15KV40B025PH 4/0 2 Hole CU Lug (CS) Bare 4/0 Type SH 15kV 25' Pigtail with Lug and Bare
SH15KV40B050PH 4/0 2 Hole CU Lug (CS) Bare 4/0 Type SH 15kV 50' Pigtail with Lug and Bare
Termination Options Available: Lug, Loadbreak Elbow, Deadbreak Elbow
AVAILABLE OPTIONS• 5kV and 15kV• MV-105 Cable• Heat Shrink Logo ID
• Custom lengths • Lug, Loadbreak Elbow, and Deadbreak Elbow
Terminations
14 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
APPLICATIONSIndustrial, electrical, and construction equipment, cranes, hoists, track systems, tools, motors, machinery, battery chargers
TYPE SJOOW 300V FLEXIBLE POWER CORD TYPE SOOW 600V FLEXIBLE POWER CORD
CONSTRUCTIONConductors – Flexible strand bare copper, ASTM B-174 and UL 62Separator – Paper tape between conductor and insulation Insulation – EPR 90ºC compound class 3 table 8 UL 62Assembly – Insulated conductors cabled together: integral filled jacket Separator –Talc for 18-10 AWG Jacket – Black CPE compound class, 90˚C + class 1.4, table 11, UL 62 integral fill Color code – ICEA S-58-679, Method 1, table 1, black, white, green
SPECIFICATIONS & STANDARDSUL 62, CSA-C 22.2 No 49
FEATURES• Durable construction allows for installation in practically
any environment
• Excellent flexibility
• Resistance to oil, solvents, ozone, weather, sunlight and water
• Flame test meets VW-1, FT2, MSHA
• Temperature range -40˚C to +90˚C
• Suitable for shallow water immersion
Part Number
ConductorSize Number
ofConductors
PowerConductorStranding
Nom.InsulationThickness
Nom. Jacket Thickness
Nom.Outer
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.
AWG No. in. mm in. mm in. mm lbs/ 1000 ft A
SJOOW18-2SJOOW18-3SJOOW18-4
18234
16/30 0.030 0.76 0.030 0.760.280.300.33
7.27.78.4
425263
10.010.07.0
SJOOW16-2SJOOW16-3SJOOW16-4
16234
26/30 0.030 0.76 0.030 0.760.310.330.36
7.98.49.1
536683
13.013.010.0
SJOOW14-2SJOOW14-3SJOOW14-4
14234
41/30 0.030 0.76 0.030 0.760.340.360.40
8.79.210.1
6888110
18.018.015.0
SJOOW12-2SJOOW12-3SJOOW12-4
12234
65/30 0.030 0.76 0.045 1.140.410.430.47
10.410.911.9
104131163
25.025.020.0
SJOOW10-2SJOOW10-3SJOOW10-4
10234
103/30 0.045 1.14 0.060 1.520.540.580.63
13.814.616.0
177225279
30.030.025.0
* Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature
TYPE SJOOW CABLE
14 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 15
TYPE SJOOW 300V FLEXIBLE POWER CORD TYPE SOOW 600V FLEXIBLE POWER CORD
APPLICATIONSIndustrial and processing equipment, cranes, hoists, rack systems, tools, construction equipment, motors, machinery, battery chargers, and electrical equipment
FEATURES• Excellent flexibility – resistance to oil, solvents,
ozone, weather, sunlight, and water
• Flame test – meets VW-1, FT2, and MSHA
• Temperature range from -40˚C to +90˚C
• Suitable for shallow water immersion
• NEC Article 700 permitted use for specific applications
• NFPA 70 permitted use – NFPA 70 permitted use in Hazardous Locations Classes I, II, III, Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140
CONSTRUCTIONConductors – Stranded bare copper, ASTM B-173 and UL 62Separator – Paper tape between conductor and insulationInsulation – EPR compound, 90˚C compound class 3, table 8, UL 62Assembly – Insulated conductors cabled together with integral filled or rubber fillers Separator – Talc for 8-2 AWG Jacket – Black CPE 90˚C compound class 1.4, UL 62, table 15 Color code – ICEA S-58-679, Method 1, table 1; 2/c, 3/c - black, white, green; 4/c, 5/c - black, white, red, green, orange
SPECIFICATIONS & STANDARDS UL 62/CSA-C 22.2 No 49
TYPE SOOW CABLE
Part Number AWG No. ofConductors
Stranding/ Diameter
Nominal Insulation Thickness
Nominal Jacket
ThicknessNominal O.D. Approx.
Weightlbs./
1000 ft.
Ampacity*30ºC
Ambient Temp.
in. mm in. mm in. mm A
SOOW8-3SOOW8-4SOOW8-5
8345
133/0.0156 0.060 1.520.1100.1250.125
2.793.183.18
0.830.931.00
21.123.525.4
452577683
40.035.028.0
SOOW6-3SOOW6-4SOOW6-5
6345
184/0.0117 0.060 1.520.1250.1400.140
3.183.563.56
0.971.051.18
24.626.730.0
641785983
55.045.036.0
SOOW4-3SOOW4-4SOOW4-5
4345
165/0.0156 0.060 1.520.1400.1550.155
3.563.943.94
1.131.251.31
28.731.833.2
91311561318
70.060.048.0
SOOW2-3SOOW2-4SOOW2-5
2345
262/0.0156 0.060 1.520.1550.1700.170
3.944.324.32
1.301.451.53
33.136.838.8
128716441900
95.080.064.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
16 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
TYPE SOOW 600V FLEXIBLE POWER CORD TYPE SC 600V ENTERTAINMENT CABLE
APPLICATIONSIndustrial and processing equipment, cranes, hoists, rack systems, tools, construction equipment, motors, machinery, battery chargers, and electrical equipment
Part Number AWG No. ofConductors
Stranding/ Diameter
Nominal Insulation Thickness
Nominal Jacket
ThicknessNominal O.D. Approx.
Weightlbs./
1000 ft.
Ampacity*30ºC
Ambient Temp.
in. mm in. mm in. mm A
SOOW18-2SOOW18-3SOOW18-4
18234
16/30 0.030 0.76 0.060 1.520.340.360.39
8.69.19.8
637487
10.010.07.0
SOOW16-2SOOW16-3SOOW16-4SOOW16-5
162345
26/30 0.030 0.76 0.060 1.520.370.390.420.49
9.310.110.512.5
7690107149
13.013.010.08.0
SOOW14-2SOOW14-3SOOW14-4
14234
41/30 0.045 1.14 0.080 2.030.500.520.57
12.613.314.4
137161192
18.018.015.0
SOOW12-2SOOW12-3SOOW12-4SOOW12-5
122345
65/30 0.045 1.14 0.095 2.410.570.590.640.76
14.415.216.517.8
184217261319
25.025.020.016.0
SOOW10-2SOOW10-3SOOW10-4SOOW10-5
102345
104/30 0.045 1.14 0.095 2.410.620.650.700.76
15.616.517.819.3
230281336409
30.030.025.020.0
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
CONSTRUCTIONConductors – Flexible stranded bare copper, ASTM B-174 and UL 62Insulation – EPR compound, 90˚C compound class 3, table 8, UL 62Assembly – Insulated conductors cabled together with integral filled or rubber filler Separator – Talc for 18-10 AWGJacket – Black CPE 90˚C compound class 1.4, table 22, UL 62Color code – ICEA S-58-679, Method 1, table 1; black, white, red, green
SPECIFICATIONS & STANDARDS UL 62/CSA-C 22.2 No 49
FEATURES• Excellent flexibility – resistance to oil, solvents,
ozone, weather, sunlight, and water
• Flame test – meets VW-1, FT2, and MSHA
• Temperature range from -40˚C to +90˚C
• Suitable for shallow water immersion
• NEC Article 700 permitted use for specific applications
• NFPA 70 permitted use NFPA 70 permitted use in Hazardous Locations Classes I, II, III, Divisions 1 & 2 as outlined in Articles 501, 502, 503 section 140
TYPE SOOW CABLE
16 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 17
TYPE SOOW 600V FLEXIBLE POWER CORD TYPE SC 600V ENTERTAINMENT CABLE
APPLICATIONSTemporary power supply applications such as TV, motion picture, indoor and outdoor theaters, sound or lighting systems, and stages
Part Number
PowerConduc-tor Size
Power Conductor Stranding/ Diameter
Nominal Jacket
Thickness
Nominal Outside
Diameter (O.D.)Approx.Weight
lbs./ 1000 ft.
Ampacity*30ºC
Ambient Temp.
AWG Ain. mm in. mm
SC8 8 7x24/.0100" 0.380 9.65 0.360 9.1 112 80
SC6 6 7x37/.010" 0.420 10.67 0.371 9.4 149 105
SC4 4 7x60/.010" 0.480 12.19 0.430 10.9 212 140
SC2 2 7x95/.010" 0.530 13.21 0.509 12.9 299 190
SC1 1 19x44/.010" 0.580 14.73 0.611 15.5 369 220
SC1/0 1/0 19x56/.010" 0.630 16.00 0.672 17.1 458 260
SC2/0 2/0 19x70/.010" 0.680 17.27 0.697 17.7 558 300
SC3/0 3/0 19x88/.010" 0.730 18.54 0.777 19.7 676 350SC4/0 4/0 19x111/.010" 0.790 20.07 0.803 20.4 826 405
* Ampacities are based on single conductor in free air, 30°C ambient air temperature 90°C conductor operating temperature per Table 400-5 (B) of the 1999 NEC
TYPE SC (STAGE CABLE)
CONSTRUCTIONConductors – Flexible strand bare copper, ASTM 172 class KSeparator – Polyester tape over conductorJacket – Black heavy duty EPR/CPE two layers bonded thermoset jacket, oil resistant, and flame retardant
SPECIFICATIONS & STANDARDS UL 62 / UL1581, CSA-C 22.2 No 96
FEATURES• For use in accordance with NEC Articles 520, 525 and
530, indoor and outdoor locations
• Flame test meets VW-1, MSHA
• Excellent flexibility, resistance to oil, solvents, ozone, aging and abrasion
• Suitable for continuous submersion in water
• Temperature range from -35°C to +105°C
18 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
GENFLEX™ TYPE PPE 2000V PORTABLE POWER CABLE GENFLEX™ TYPE W 2000V PORTABLE POWER CABLE
APPLICATIONSHeavy-duty temporary or permanent power for portable generators, air conditioning, grounding, power extension, shore power, mining and oil drillling
CONSTRUCTIONNominal Voltage – 2000VConductors – Flexible annealed No. 30 gauge bare copper strandingSeparator – Tape separator between conductor and insulationInsulation – Ethylene-propylene rubber (EPR)High Strength Fiber Braid – Provides extra strength between the insulation and jacketJacket – Durable RoHS compliant TPE
SPECIFICATIONS & STANDARDS • ISO 9001: 2008 certified• ISO 14001: 2004 certified
Part Number
ConductorSize Stranding
Nom.InsulationThickness
Nom. Jacket Thickness
Nom.O.D.
Ampacities*30ºC
Ambient Temp.AWG or MCM in. in. in. in. A
PPE8 8 AWG 7/24/010 (168) 0.060 0.075 0.455 80PPE6 6 AWG 7/38/010 (266) 0.060 0.095 0.523 105PPE4 4 AWG 7/60/010 (420) 0.060 0.095 0.591 140PPE2 2 AWG 7/95/010 (665) 0.070 0.095 0.662 190PPE1 1 AWG 19/44/010 (836) 0.080 0.095 0.723 220
PPE1/0 1/0 AWG 19/56/010 (1064) 0.080 0.095 0.773 260PPE2/0 2/0 AWG 19/70/010 (1330) 0.080 0.095 0.825 300PPE3/0 3/0 AWG 19/88/010 (1672) 0.080 0.095 0.880 350PPE4/0 4/0 AWG 19/111/010 (2109) 0.080 0.095 0.950 405PPE250 250MCM 19/133/010 (2527) 0.098 0.095 1.041 455PPE300 300MCM 19/7/23/010 (3059) 0.098 0.095 1.103 505
* Based on single conductor in free air, 30ºC ambient air temperature 90ºC conductor temperature per 2005 NEC Table 310.17
GENFLEX™ TYPE PPE CABLE
FEATURES• Made from annealed no. 30 gauge bare copper stranding
• Durable EPR (ethylene-propylene rubber) jacket with black heavy-duty CPE thermoset compound
• Excellent Flexibility – EPR/CPE single conductor portable power cable
• Excellent impact and abrasion resistant
• Ozone, sunlight, oil, grease, weather, and chemical resistant
• Operating Temperatures range from -40°C to 90°C wet or dry
• Rated up to 2000V
• UL listed and MSHA approved
AVAILABLE OPTIONS• Custom cable print and lengths
• Sequential markings
• Colored cable
18 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 19
GENFLEX™ TYPE PPE 2000V PORTABLE POWER CABLE GENFLEX™ TYPE W 2000V PORTABLE POWER CABLE
APPLICATIONSHeavy-duty industrial power applications that require flexibility and reliability include temporary and permanent power
Part Number
Conductor Size
Power Conductor
Size Stranding/ Diameter
Nominal Insulation Thickness
Nominal O.D. Approx.Weight
Ampacity*30ºC
Ambient Temp.AWG or
MCMNo. ofWires in. mm in. mm lbs./
1000 ft. kgs/km A
W8 8 AWG 162/30 133/0.0156 0.060 1.52 0.441 11.2 145 216 80
W6 6 AWG 264/30 184/0.0117 0.060 1.52 0.511 12.9 200 298 105
W4 4 AWG 418/30 165/0.0156 0.060 1.52 0.564 14.3 255 379 140W2 2 AWG 660/30 262/0.0156 0.060 1.52 0.651 16.5 375 558 190
W1 1 AWG 836/30 133/0.0156 0.080 2.03 0.729 18.5 475 707 220
W1/0 1/0 AWG 1056/30 184/0.0117 0.080 2.03 0.751 19.0 530 789 260
W2/0 2/0 AWG 1320/30 165/0.0156 0.080 2.03 0.800 20.3 650 967 300W3/0 3/0 AWG 1672/30 262/0.0156 0.080 2.03 0.856 21.7 750 1116 350
W4/0 4/0 AWG 2090/30 133/0.0156 0.080 2.03 0.981 24.9 970 1444 405
W250 250MCM 2496/30 184/0.0117 0.095 2.41 1.001 25.4 1130 1682 455
W300 300MCM 3416/30 165/0.0156 0.095 2.41 1.133 28.8 1420 2116 505
W500 500MCM 1221 37x33 184/0.0117 0.095 2.41 1.255 31.9 1913 2847 700
*Ampacity – Free air measured; based on continuous duty at 90°C conductor temperature
FEATURES• Made from annealed no. 30 gauge bare copper stranding
• Durable EPR (ethylene-propylene rubber) jacket with black heavy-duty CPE thermoset compound
• Excellent Flexibility – EPR/CPE single conductor portable power cable
• Excellent impact and abrasion resistant
• Ozone, sunlight, oil, grease, weather, and chemical resistant
• Operating Temperatures range from -40°C to 90°C wet or dry
• Rated up to 2000V
• UL listed and MSHA approved
AVAILABLE OPTIONS• Custom cable print, sequential markings, preassembled sets,
and custom lengths
GENFLEX™ TYPE W CABLE
CONSTRUCTIONConductors – Stranded bare copper, ASTM B-173 and UL 62Separator – Paper tape between conductor and insulationInsulation – EPR compound, 90˚C compound class 3, table 8, UL 62Assembly – Insulated conductors cabled together with integral filled or rubber fillers Separator – Talc for 8-2 AWG Jacket – Black CPE 90˚C compound class 1.4, UL 62, table 15 Color code – ICEA S-58-679, Method 1, table 1; 2/c, 3/c - black, white, green; 4/c, 5/c - black, white, red, green, orange
SPECIFICATIONS & STANDARDS UL 62/CSA-C 22.2 No 49
20 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
APPLICATIONSType W Multi-Conductor Power Cable is designed for portable power systems and other industrial applications including mining applications where bare grounding conductors are not required.
TYPE W MULTI-CONDUCTOR 2/C TYPE W MULTI-CONDUCTOR 3/C
Part Number
ConductorSize Power
ConductorStranding
Nom.InsulationThickness
NominalOuter
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.
AWG in. mm in. mm lbs./ 1000 ft. kgs/km A
W8-2 8 AWG 133 7x19 0.060 1.52 0.83 21.1 391 581 74
W6-2 6 AWG 133 7x19 0.060 1.52 0.94 23.9 571 849 99
W4-2 4 AWG 259 7x37 0.060 1.52 1.07 27.3 793 1180 130
W2-2 2 AWG 259 7x37 0.060 1.52 1.26 32.1 1142 1699 174* Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature
2 CONDUCTOR TYPE W CABLE
CONSTRUCTIONConductors –Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58 Separator –Tape separator between the conductor and insulation Insulation – Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-8 Assembly – Conductors and rubber fillers cabled to form round core Reinforcement – Single faced rubber filled binder tape over insulation Jacket – Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4Color Code – ICEA S-75-381 sec 3.18; black, white
FEATURES• Excellent flexibility
• Operating Temperature – Rated and flexible at –40ºC to +90ºC
• Water, flame, ozone, sunlight, oil, grease, weather, and chemical resistant
• Excellent resistance to impact and abrasion
SPECIFICATIONS & STANDARDS ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
20 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 21
TYPE W MULTI-CONDUCTOR 2/C TYPE W MULTI-CONDUCTOR 3/C
Part Number
ConductorSize Power
ConductorStranding
Nom.InsulationThickness
NominalOuter
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.
AWG in. mm in. mm lbs./ 1000 ft. kgs/km A
W8-3 8 AWG 133 7x19 0.060 1.52 0.91 23.1 541 805 65
W6-3 6 AWG 133 7x19 0.060 1.52 1.01 25.7 715 1064 87
W4-3 4 AWG 259 7x37 0.060 1.52 1.05 26.5 1010 1503 114
W2-3 2 AWG 259 7x37 0.060 1.52 1.32 33.6 1405 2091 152
W1-3 1 AWG 259 7x37 0.080 2.03 1.51 38.4 1734 2581 177
W1/0-3 1/0 AWG 266 19x14 0.080 2.03 1.63 41.4 2030 3010 205
W2/0-3 2/0 AWG 342 19x18 0.080 2.03 1.73 44.0 2566 3818 237
W3/0-3 3/0 AWG 418 19x22 0.080 2.03 1.85 47.0 2885 4293 274
W4/0-3 4/0 AWG 532 19x28 0.080 2.03 1.99 50.6 3479 5177 316
W250-3 250 MCM 627 19x33 0.095 2.41 2.39 60.7 4368 6500 352W350-3 350 MCM 888 37x24 0.095 2.41 2.66 67.5 5895 8772 433W500-3 500 MCM 1221 37x33 0.095 2.41 2.98 75.8 7820 11638 536
* Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature
3 CONDUCTOR TYPE W CABLE
CONSTRUCTIONConductors –Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58 Separator –Tape separator between the conductor and insulation Insulation – Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-9Assembly – Conductors and rubber fillers cabled to form round core Reinforcement – Single faced rubber filled binder tape over insulation Jacket – Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4Color Code – ICEA S-75-381 sec 3.18; black, white, green
FEATURES• Excellent flexibility
• Operating Temperature – Rated and flexible at –40ºC to +90ºC
• Water, flame, ozone, sunlight, oil, grease, weather, and chemical resistant
• Excellent resistance to impact and abrasion
SPECIFICATIONS & STANDARDS ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
APPLICATIONSType W Multi-Conductor Power Cable is designed for portable power systems and other industrial applications including mining applications where bare grounding conductors are not required.
22 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
APPLICATIONSType W Multi-Conductor Power Cable is designed for portable power systems and other industrial applications including mining applications where bare grounding conductors are not required.
TYPE W MULTI-CONDUCTOR 4/C TYPE W MULTI-CONDUCTOR 5/C
4 CONDUCTOR TYPE W CABLE
CONSTRUCTIONConductors –Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58 Separator – Tape separator between conductor and insulation Insulation – Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-10 Assembly – Conductors and rubber fillers cabled to form round core Reinforcement – Single faced rubber filled binder tape over insulation Jacket – Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4Color Code – ICEA S-75-381 sec 3.18; black, white, green, red
FEATURES• Excellent flexibility
• Operating Temperature – Rated and flexible at –40ºC to +90ºC
• Water, flame, ozone, sunlight, oil, grease, weather, and chemical resistant
• Excellent resistance to impact and abrasion
SPECIFICATIONS & STANDARDS ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
Part Number
ConductorSize Power
ConductorStranding
Nom.InsulationThickness
NominalOuter
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.
AWG in. mm in. mm lbs./ 1000 ft. kgs/km A
W8-4 8 AWG 133 7x19 0.060 1.52 0.97 24.6 656 976 52
W6-4 6 AWG 133 7x19 0.060 1.52 1.11 28.3 908 1352 69
W4-4 4 AWG 259 7x37 0.060 1.52 1.26 32.1 1262 1878 91
W2-4 2 AWG 259 7x37 0.060 1.52 1.43 36.3 1759 2618 121
W1-4 1 AWG 259 7x37 0.080 2.03 1.71 43.4 2322 3456 141
W1/0-4 1/0 AWG 266 19x14 0.080 2.03 1.78 45.2 2721 4050 164
W2/0-4 2/0 AWG 342 19x18 0.080 2.03 1.89 48.0 3293 4901 189
W3/0-4 3/0 AWG 418 19x22 0.080 2.03 2.02 51.4 3849 5729 219
W4/0-4 4/0 AWG 532 19x28 0.080 2.03 2.22 56.3 4765 7092 252* Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature
22 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 23
TYPE W MULTI-CONDUCTOR 4/C TYPE W MULTI-CONDUCTOR 5/C
5 CONDUCTOR TYPE W CABLE
CONSTRUCTIONConductors – Flexible strand tin copper, ASTM B-172 and ICEA S-75-381/NEMA WC58 Separator – Tape separator between conductor and insulation Insulation – Ethylene-propylene rubber (EPR), ICEA S-75-381 sec 3.15, table 3-16 Assembly – Conductors and rubber fillers cabled to form round core Reinforcement – Single faced rubber filled binder tape over insulation Jacket – Black heavy duty CPE thermoset compound, ICEA S-75-381 sec 3.4, table 3-4 Color Code – ICEA S-75-381 sec 3.18; black, white, red, green, orange
FEATURES• Excellent flexibility
• Operating Temperature – Rated and flexible at –40ºC to +90ºC
• Water, flame, ozone, sunlight, oil, grease, weather, and chemical resistant
• Excellent resistance to impact and abrasion
SPECIFICATIONS & STANDARDS ICEA S-75-381/NEMA WC58, ICEA S-95-658/NEMA WC70, ASTM B172, ASTM B 33, UL 44
APPLICATIONSType W Multi-Conductor Power Cable is designed for portable power systems and other industrial applications including mining applications where bare grounding conductors are not required.
Part Number
ConductorSize Power
ConductorStranding
Nom.InsulationThickness
NominalOuter
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.
AWG in. mm in. mm lbs./ 1000 ft. kgs/km A
W8-5 8 AWG 133 7x19 0.060 1.52 1.07 27.2 776 1154 52
W6-5 6 AWG 133 7x19 0.060 1.52 1.24 31.5 1024 1524 69
W4-5 4 AWG 259 7x37 0.060 1.52 1.36 35.2 1432 2131 91
W2-5 2 AWG 259 7x37 0.060 1.52 1.56 39.8 2051 3052 121
W1-5 1 AWG 259 7x37 0.080 2.03 1.85 47.1 2665 3967 141
W1/0-5 1/0 AWG 266 19x14 0.080 2.03 1.98 50.4 3406 5069 164
W2/0-5 2/0 AWG 342 19x18 0.080 2.03 2.13 54.1 3596 5351 189
W3/0-5 3/0 AWG 418 19x22 0.080 2.03 2.27 57.6 4728 7035 219
W4/0-5 4/0 AWG 532 19x28 0.080 2.03 2.46 62.6 5512 8203 252* Ampacity – Free air measured; Based on continuous duty at 90°C conductor temperature
24 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
TYPE DLO (DIESEL LOCOMOTIVE CABLE) MEDIUM VOLTAGE MV-105 5kV
APPLICATIONSType DLO 2000V Power Cable is designed for uses requiring flexible heavy-duty power cables in portable or fixed installations such as leads for motors, generators, batteries, and jumper cables. Deep well Submersible Pump Cable applications
Part Number
ConductorSize Power
ConductorStranding
ConductorDiameter
Nom.InsulationThickness
Nom. Jacket
Thickness
MaximumOuter
DiameterApprox.Weight
Ampacities*30ºC
Ambient Temp.AWG or
MCM in. in. in. in. mm lbs./ 1000 ft.
kgs/km A
DLO2 2 AWG 150/24 0.314 0.060 0.030 0.489 12.4 248 369 190
DLO1/0 1/0 AWG 275/24 0.420 0.080 0.045 0.642 16.3 480 714 260
DLO2/0 2/0 AWG 325/24 0.460 0.080 0.045 0.681 17.3 558 830 300
DLO4/0 4/0 AWG 550/24 0.587 0.080 0.045 0.870 22.1 872 1298 405
DLO262 262MCM 650/24 0.660 0.095 0.065 0.990 25.1 1068 1589 471
DLO313 313MCM 775/24 0.725 0.095 0.065 1.055 26.8 1258 1872 511
DLO373 373MCM 925/24 0.787 0.095 0.065 1.125 28.6 1462 2176 590
DLO444 444MCM 1100/24 0.870 0.095 0.065 1.205 30.6 1726 2568 656
DLO535 535MCM 1325/24 0.950 0.110 0.065 1.290 33.1 2018 3046 731
DLO646 646MCM 1600/24 1.040 0.110 0.065 1.410 35.8 2416 3595 815
DLO777 777MCM 1925/24 1.130 0.110 0.065 1.500 38.1 2881 4287 905* Based on single conductor in free air, 30ºC ambient air temperature 90ºC conductor temperature per 2005 NEC Table 310.17
TYPE DLO 2000V RHH/RHW-2 600V and 2000V, RW-90 CSA, 1kV CABLE
CONSTRUCTIONNominal Voltage – RHH/RHW-2 600V and 2000V, RW-90 CSA, 1kV, DLO 2kVConductors – Flexible strand tin coated copper conductor, B-172, ASTM B-33Separator – Tape separator between conductor and insulationInsulation – Ethylene-propylene rubber (EPR), UL, CSA, ICEA, AAR RP-588, 90ºC Jacket – Black heavy duty, thermoset CPE, ICEA S-95-658 NEMA WC70, AAR RP-586Bending Radius – For fixed – minimum 4xD; For flexible – minimum 6xD, D – diameter of cableTorsion Stresses – ±100 ˚/m
SPECIFICATIONS & STANDARDS UL 44, ICEA S-95-658/NEMA WC70, UL 1685, IEEE-1202, CSA C22.2 No. 38, ASTM B 8, ASTM B 33, AAR, RP-588 RP-586
FEATURES• UL listed RHH/RHW-2 600V and 2000V
for black jacket • Rated 2kV DLO, 1kV RW90• 90˚C (dry) 90˚C (wet)• Ozone, sunlight, oil, grease, weather, water,
chemical and abrasion resistant jacket • Rated RW90-TC (Tray Cable) for sizes 1/0 AWG
and larger • MSHA,VW-1, SUN RES, FOR CT USE for sizes
1/0 AWG and larger and for black jacket• Limited Smoke (LS) ST1 in accordance with (UL)
1685• CSA listed RW90, RW90-TC for black jacket 1kV
24 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 25
TYPE DLO (DIESEL LOCOMOTIVE CABLE) MEDIUM VOLTAGE MV-105 5kV
APPLICATIONSIndustrial and commercial applications including chemical and petrochemical plants; electrical utility plants; water treatment facilities; textile, steel, and paper mills; airports; shopping malls; military bases; medical facilities; and sports stadiums
Part Number
Power Conductor
Size
Nominal Insulation Thickness
DiameterOver
Insulation Jacket
ThicknessOuter
DiameterCable
Weight Ampacities*
AWG/MCM mils in. mils in. lbs./kft Isolated in Air
Direct Buried
Underground Duct
#2MV105-05KV 2AWG-1 115 0.55 60 0.78 425 215 250 155
#1MV105-05KV 1AWG-1 115 0.60 60 0.80 515 250 280 180
1/0MV105-05KV 1/0AWG-1 115 0.65 60 0.85 580 290 320 210
2/0MV105-05KV 2/0AWG-1 115 0.69 80 0.95 675 330 365 235
3/0MV105-05KV 3/0AWG-1 115 0.75 80 1.00 860 385 415 270
4/0MV105-05KV 4/0AWG-1 115 0.80 80 1.05 985 445 465 310
250MV105-05KV 250MCM-1 115 0.85 80 1.10 1130 495 510 345
350MV105-05KV 300MCM-1 115 0.95 80 1.20 1480 615 615 410
500MV105-05KV 350MCM-1 115 1.10 80 1.35 2000 775 745 505
750MV105-05KV 500MCM-1 115 1.30 80 1.55 2870 1000 910 630
1000MV105-05KV 1000MCM-1 115 1.40 80 1.70 3690 1200 1055 720* Ampacities in “Underground Duct” per NEC 2011 Table 310.60(C) (77). Ampacities “Isolated in Air” per NEC 2011 Table 310.60(C) (69).
Ampacities “Direct Buried” per NEC 2011 Table 310.60(C) (81).
CONSTRUCTIONConductors – Class B compact annealed uncoated copperConductor shielding – Extruded layer of semi-conducting compound applied under simultaneous triple extrusion processInsulation – Extruded layer of 105˚C rated Ethylene Propylene Rubber (EPR)Insulation shield – Extruded layer of semi-conducting compound applied by triple extrusion processMetallic shield – 5 mil bare copper tape applied helically with an overlapJacket – Extruded layer of black sunlight resistant Polyvinyl Chloride (PVC)
MV-105 5KV/8KV CABLE
FEATURES• Durable construction allows for installation in
practically any environment
• 105ºC insulation rating allows for higher ampacity rating of cable
• Continuous conductor operating temperature 105ºC
• Emergency overload rating 140ºC
• Short circuit rating 250ºC
• UL listed as Type MV-105
• Oil and sunlight resistant
• Flame retardant PVC jacket
• Listed for CT use for sizes 1/0 AWG and larger
SPECIFICATIONS & STANDARDS Medium Voltage 5kV 133%/8kV 100% Copper Conductor, Copper Tape Shielded UL 1072, ASTM B-496, ICEA S-93-639, ICEA S-97-682, AEIC CS8-2000, IEEE 383
26 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
MEDIUM VOLTAGE MV-105 15kV JUMPER CABLE 5kV/8kV
Part Number
Power Conductor
Size
Nominal Insulation Thickness
DiameterOver
Insulation Jacket
ThicknessOuter
DiameterCable
Weight Ampacities*
AWG/MCM mils in. mils in. lbs./kft Isolated in Air
Direct Buried
Underground Duct
#2MV105-15KV 2AWG-1 220 0.75 80 1.03 503 215 225 165
#1MV105-15KV 1AWG-1 220 0.79 80 1.05 700 250 260 185
1/0MV105-15KV 1/0AWG-1 220 0.82 80 1.09 770 290 295 215
2/0MV105-15KV 2/0AWG-1 220 0.86 80 1.13 865 335 335 245
3/0MV105-15KV 3/0AWG-1 220 0.92 80 1.17 1040 385 380 275
4/0MV105-15KV 4/0AWG-1 220 0.97 80 1.21 1165 445 435 315
250MV105-15KV 250MCM-1 220 1.02 80 1.30 1320 495 475 345
350MV105-15KV 300MCM-1 220 1.12 80 1.40 1680 610 575 415
500MV105-15KV 350MCM-1 220 1.26 80 1.52 2200 765 700 500
750MV105-15KV 500MCM-1 220 1.41 110 1.77 3115 990 865 610
1000MV105-15KV 1000MCM-1 220 1.97 110 1.95 4060 1185 1005 690* Ampacities in “Underground Duct” per NEC 2011 Table 310.60(C) (77). Ampacities “Isolated in Air” per NEC 2011 Table 310.60(C) (69).
Ampacities “Direct Buried” per NEC 2011 Table 310.60(C) (81).
CONSTRUCTIONConductors – Class B compact annealed uncoated copperConductor shielding – Extruded layer of semi-conducting compound applied under simultaneous triple extrusion processInsulation – Extruded layer of 105˚C rated Ethylene Propylene Rubber (EPR)Insulation shield – Extruded layer of semi-conducting compound applied by triple extrusion processMetallic shield – 5 mil bare copper tape applied helically with an overlapJacket – Extruded layer of black sunlight resistant Polyvinyl Chloride (PVC)
MV-105 15KV CABLE
FEATURES• Durable construction allows for installation in
practically any environment
• 105ºC insulation rating allows for higher ampacity rating of cable
• Continuous conductor operating temperature 105ºC
• Emergency overload rating 140ºC
• Short circuit rating 250ºC
• UL listed as Type MV-105
• Oil and sunlight resistant
• Flame retardant PVC jacket
• Listed for CT use for sizes 1/0 AWG and larger
SPECIFICATIONS & STANDARDS Medium Voltage 15kV 133% Copper Conductor, Copper Tape Shielded UL 1072, ASTM B-496, ICEA S-93-639, ICEA S-97-682, AEIC CS8-2000, IEEE 383
APPLICATIONSIndustrial and commercial applications including chemical and petrochemical plants; electrical utility plants; water treatment facilities; textile, steel, and paper mills; airports; shopping malls; military bases; medical facilities; and sports stadiums
26 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 27
APPLICATIONSUsed as a flexible power lead for temporary connections and other vindustrial applications
MEDIUM VOLTAGE MV-105 15kV JUMPER CABLE 5kV/8kV
Part Number
Power Conductor
Size ConductorStranding
Nominal Insulation Thickness
Nominal Jacket
Thickness
Nominal Outside
Diameter
Approx.Weight
Ampacity*40ºC
Ambient Temp.lbs./
1000 ft.kgs/ kmAWG/MCM in. in. in. mm A
JC2 2 259x0.0159 0.175 0.080 0.820 20.8 480 714 195
JC1/0 1/0 414x0.0159 0.175 0.080 0.905 23.0 639 951 255
JC2/0 2/0 522x0.0159 0.175 0.080 0.997 25.3 747 1112 293
JC4/0 4/0 829x0.0159 0.175 0.080 1.140 29.0 1051 1564 389
JC350 350 1361x0.0159 0.175 0.080 1.305 33.1 1584 2357 543
JC500 500 1921x0.0159 0.175 0.080 1.410 35.8 2082 3099 678
*Ampacity and Impedance – Free air measured; Based on continuous duty at 90°C conductor temperature
CONSTRUCTIONConductors – Flexible strand tin coated copper, ASTM B-172 and ICEA S-75-381Separator – Synthetic semi-conducting tape separator between the conductor and insulationInsulation – Ethylene-propylene rubber (EPR), UL 1072Jacket – Red heavy-duty CPE thermoset compound, ICEA S-75-381 sec 3.22
FEATURES• Excellent flexibility
• Water resistant
• Rated and flexible at –40ºC to +90ºC
• Ozone, sunlight, oil, grease, weather, and chemical resistant
SPECIFICATIONS & STANDARDS According to ICEA S-97-682, ICEA S-75-381/NEMA WC-58, ASTM B172, ASTM B 33, UL 1072
JUMPER CABLE 5KV/8KV
28 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
TYPE SH 5kV MEDIUM VOLTAGE POWER CABLE TYPE SH 15kV MEDIUM VOLTAGE POWER CABLE
TYPE SH 5KV MEDIUM VOLTAGE POWER CABLE
CONSTRUCTIONConductors – Annealed flexible stranded tin coated copper Class I in accordance with ASTM B-172 and ICEA S-75-381Conductor shielding – Semi-conducting tape + layer over the conductorInsulation – Ethylene-propylene rubber (EPR)Insulation shield – Semi-conducting tape + Composite tinned copper/nylon braid. Covering minimum 60% Cable consist of EPR insulated central conductor with helically applied copper drain wire shield conductors over the insulation semi-conductive tape shield. Reinforcing tape over insulation shieldJacket – Black heavy-duty thermosetting poly- chloroprene jacket
FEATURES• Excellent flexibility
• Highly resistant to ozone, sun, weather and flame
• Rated and flexible at –40ºC
• Excellent impact and abrasion resistant
• Oil and heat resistant
SPECIFICATIONS & STANDARDS According to ICEA S-75-381/NEMA WC-58, ASTM B172, ASTM B 33
Part Number
Power Conductor
Size ConductorStranding
Nominal Insulation Thickness
Nominal Jacket
ThicknessApprox. O.D.
Approx.Weight
Ampacity40ºC
Ambient Temp.lbs./
1000 ft.kgs/ kmAWG/MCM in. in. in. A
#2SH-05KV 2AWG-1 259x0.0157 0.110 0.125 0.902 575 856 195
#1SH-05KV 1AWG-1 259x0.0177 0.110 0.125 0.953 659 981 225
1/0SH-05KV 1/0AWG-1 266x0.0197 0.110 0.140 1.028 786 1170 260
2/0SH-05KV 2/0AWG-1 342x0.0193 0.110 0.140 1.055 890 1324 299
3/0SH-05KV 3/0AWG-1 418x0.0197 0.110 0.155 1.154 1075 1600 345
4/0SH-05KV 4/0AWG-1 532x0.0197 0.110 0.155 1.201 1240 1846 400
250SH-05KV 250MCM-1 627x0.0197 0.120 0.155 1.303 1435 2136 444
300SH-05KV 300MCM-1 740x0.0197 0.120 0.170 1.398 1655 2462 496
350SH-05KV 350MCM-1 888x0.0193 0.120 0.170 1.441 1858 2765 549
500SH-05KV 500MCM-1 1221x0.0197 0.120 0.190 1.630 2471 3677 688
APPLICATIONSSingle Conductor Type SH 5000V Medium Voltage Portable Power Cable is designed for use on mobile substation equipment and other industrial applications
28 | CUT TO LENGTH CABLE 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CUT TO LENGTH CABLE | 29
TYPE SH 5kV MEDIUM VOLTAGE POWER CABLE TYPE SH 15kV MEDIUM VOLTAGE POWER CABLE
Part Number
Power Conductor
Size ConductorStranding
Nominal Insulation Thickness
Nominal Jacket
ThicknessApprox. O.D.
Approx.Weight
Ampacity40ºC
Ambient Temp.lbs./
1000 ft.kgs/ kmAWG/MCM in. in. in. A
#2SH-15KV 2AWG-1 259x0.0157 0.210 0.155 1.165 847 1261 195
#1SH-15KV 1AWG-1 259x0.0177 0.210 0.155 1.216 944 1405 225
1/0SH-15KV 1/0AWG-1 266x0.0197 0.210 0.155 1.260 1052 1566 259
2/0SH-15KV 2/0AWG-1 342x0.0193 0.210 0.155 1.307 1183 1761 298
3/0SH-15KV 3/0AWG-1 418x0.0197 0.210 0.170 1.398 1382 2057 343
4/0SH-15KV 4/0AWG-1 532x0.0197 0.210 0.170 1.453 1570 2337 397
250SH-15KV 250MCM-1 627x0.0197 0.210 0.170 1.543 1771 2636 440
300SH-15KV 300MCM-1 740x0.0197 0.210 0.170 1.606 1926 2920 491
350SH-15KV 350MCM-1 888x0.0193 0.210 0.190 1.658 2192 3261 543
500SH-15KV 500MCM-1 1221x0.0197 0.210 0.190 1.807 2701 4123 678
TYPE SH 15KV MEDIUM VOLTAGE POWER CABLE
CONSTRUCTIONConductors – Annealed flexible stranded tin coated copper Class I in accordance with ASTM B-172 and ICEA S-75-381Conductor shielding – Semi-conducting tape + layer over the conductorInsulation – Ethylene-propylene rubber (EPR)Insulation shield – Semi-conducting tape + Composite tinned copper/nylon braid. Covering minimum 60% Cable consist of EPR insulated central conductor with helically applied copper drain wire shield conductors over the insulation semi-conductive tape shield. Reinforcing tape over insulation shieldJacket – Black heavy-duty thermosetting poly- chloroprene jacket
FEATURES• Excellent flexibility
• Highly resistant to ozone, sun, weather and flame
• Rated and flexible at –40ºC
• Excellent impact and abrasion resistant
• Oil and heat resistant
SPECIFICATIONS & STANDARDS According to ICEA S-75-381/NEMA WC-58, ASTM B172, ASTM B 33
APPLICATIONSSingle Conductor Type SH 15000V Medium Voltage Portable Power Cable is designed for use on mobile substation equipment and other industrial applications
30 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
PORTABLE POWER DISTRIBUTION UNITS PORTABLE POWER DISTRIBUTION UNITS
HEAVY-DUTY TEMPORARY POWER DISTRIBUTION UNITS
Part Number Rating Distribution
DevicesReceptacle
RatingsReceptacleComponent
Protection
Overload GFCI
RB300M 50A, 120/240 V/AC max.
(6) WR Duplex Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
WRBR20BK L630R CS6375RB CS6369RB
XX--
XX--
RB300M-L5 50A, 120/240 V/AC max.
(6) WR Duplex Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 125V 50A, 125/250V 50A, 125/250V
WRBR20BK L530R CS6375RB CS6369RB
XX--
XX--
RB301M 50A, 120/240 V/AC max.
(6) Single Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
1877BK L630R CS6375RB CS6369RB
XX--
X---
RB302M 50A, 120/240 V/AC max.
(6) Locking Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
L530R L630R CS6375RB CS6369RB
XX--
X---
RB303M 50A, 120/240 V/AC max.
(3) Single Receptacles (3) Locking Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
1877BK L520R L630R CS6375RB CS6369RB
XXX--
X-- --
RB3001M 50A, 120/240 V/AC max.
(7) WR Duplex Receptacles (1) Locking Inlet (1) Locking Outlet
20A, 125V 50A, 125/250V 50A, 125/250V
WRBR20BK CS6375RB CS6369RB
X--
X--
RB3021M 50A, 120/240 V/AC max.
(7) Locking Receptacles (1) Locking Inlet (1) Locking Outlet
20A, 125V 50A, 125/250V 50A, 125/250V
L520R CS6375RB CS6369RB
X--
X--
FEATURES• High visibility OSHA Safety Red powder-coated
weather resistant enclosures
• Stackable units securely lock together for safe transport and storage
• Weatherproof outlet covers and flip-up circuit breaker cover prevent accidental tripping and protect from damage and weather
APPLICATIONSPortable power distribution units safely distribute temporary power for industrial and construction job sites, live entertainment events, film sets, and all of your temporary power needs
50A Input20A, 30A, 50A Output 120/240 VAC (Max.)
30 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CABLE ACCESSORIES | 31
PORTABLE POWER DISTRIBUTION UNITS PORTABLE POWER DISTRIBUTION UNITS
HEAVY-DUTY TEMPORARY POWER DISTRIBUTION UNITS
Part Number Rating Distribution
DevicesReceptacle
RatingsReceptacleComponent
Protection
Overload GFCI
RB300ME 50A, 120/240 V/AC max.
(6) WR Duplex Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
WRBR20BK L630R CS6375RB CS6369RB
XX--
X---
RB300ME-L5 50A, 120/240 V/AC max.
(6) WR Duplex Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 125V 50A, 125/250V 50A, 125/250V
WRBR20BK L530R CS6375RB CS6369RB
XX--
X---
RB301ME 50A, 120/240 V/AC max.
(6) Single Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
1877BK L630R CS6375RB CS6369RB
XX--
X---
RB302ME 50A, 120/240 V/AC max.
(6) Locking Receptacles (1) Locking Receptacle (1) Locking Inlet (1) Locking Outlet
20A, 125V 30A, 250V 50A, 125/250V 50A, 125/250V
L530R L630R CS6375RB CS6369RB
XX--
X---
FEATURES• Safely centralize and distribute temporary
power on the job and construction site
• Heavy-duty safety yellow steel enclosure provides NEMA 3R weather resistance for durability and long life
• Units securely lock together for safe transport and storage
• Weatherproof outlet covers and flip-up circuit breaker cover prevent accidental tripping and protect from damage and weather
• Designed with two devices per circuit
APPLICATIONSPortable power distribution units provide reliable power for industrial and construction sites, live entertainment events, film sets, and all of your temporary power needs
50A Input20A, 30A, 50A Output 120/240 VAC (Max.)
32 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
CONNECTORS CONNECTORS
APPLICATIONSGenErgy sells and stocks a wide variety of connectors in addition to those listed here. Contact customer service at 800-308-1330 for assistance with your application requirements.
Part Number Description
16A21-X* 16 Series, Female-Male-Male, Multi-Way Connector, Paralleling Tee, 400A
16A22-X* 16 Series, Male-Female-Female, Multi-Way Connector, Paralleling Tee, 400A
T’S/PARALLELING T’S
Part Number Description
16A31-X*16-Series, Soft Tapping Tee, Female Plug to Male/Male Tee, 24" Cable Length
16A32-X*16 Series, Soft Tapping Tee, Female Plug to Male/Female Tee, 24" Cable Length
SOFT TAPPING T’S
Part Number Description
16A24-X* Female-Female Turnaround, Double, 400A, 16 Series
16A25-X* Male-Male Turnaround, Double, 400A, 16 Series
TURNAROUNDS/MULTI-WAY CONNECTORS
THREE-FERS/3-FERSPart Number Description
16A23-X*16 Series, Three-Fer 45 Degree Single Pole Cam Type Multi-Way Connector Reverse Male-Fe-male-Female-Female
16A26-X*16 Series, Three-Fer 45 Degree Single Pole Cam Type Multi-Way Connector Reverse Female-Male-Male-Male
X* = Color of ConnectorE Black Y YellowW White O OrangeR Red H BrownG Green B Blue
32 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CABLE ACCESSORIES | 33
CONNECTORS CONNECTORS
Shoo-Pins | Compression Lugs | Three-Fers | T’s | Soft-Tapping T’s | Turnarounds | Snap Back Covers | 15 Series Cam Lock Single Set Screw Connectors | 16 and 17 Series Cam Lock Double Set Screw Connectors | Insulated Receptacles | Protective Caps | Center Pins | Offset Pins | Butt Splices | Twist-Lock Connectors
Cam-lock receptacles and plugs allow you to quickly and safely connect and disconnect power systems. Appropriate usage includes concerts and carnivals, connecting generators, standby power, and load testing hospitals, utilities, and heavy industrial environments.
• Rated up to 600V• UL and CSA listed• Brass contact• TPE connector body• Black, white, brown, yellow, red, orange, green
and blue connector colors available
Part Number Description16D22-X* Male, DSS, #2-2/0 AWG, 16 Series Cam
16D31-X* Female, DSS, #2-2/0 AWG, 16 Series Cam
16D24-X* Male, DSS, 2/0-4/0 AWG, 16 Series Cam
16D33-X* Female, DSS, 2/0-4/0 AWG, 16 Series Cam
Part Number Description16R21-X* M Receptacle, DSS, #2 – 4/0 AWG
16R22-X* F Receptacle, DSS, #2 – 4/0 AWG
16R23-X* M Receptacle, Threaded, #2 – 4/0 AWG, 3/4"
16R24-X* F Receptacle, Threaded, #2 – 4/0 AWG, 3/4"
16R25-X* M Receptacle, Threaded, #2 – 4/0 AWG, 1 1/4"
16R26-X* F Receptacle, Threaded, #2 – 4/0 AWG, 1 1/4"
SERIES 16 CAM LOCK DSS CONNECTORS
INSULATED RECEPTACLES
Part Number Description16S31-X* 16 Series, Snap Back Cover Enclosure Assembly
SNAP BACK COVERS
Part Number Description15D21-X* Male, Single Set Screw, #8 – #4 AWG, 15 Series
15D22-X* Female, Single Set Screw, #8 – #4 AWG, 15 Series
SERIES 15 CAM LOCK SSS CONNECTORS
Part Number Description16P21-X* 16 Series, Male Protective Cap with Lanyard
16P22-X* 16 Series, Female Protective Cap with Lanyard
PROTECTIVE CAPS
Part Number Description17D21-X* Male, DSS, 250 – 350 MCM, 17 Series Cam
17D23-X* Female, DSS, 250 – 350 MCM, 17 Series Cam
17D22-X* Male, DSS, 350 – 500 MCM, 17 Series Cam
17D24-X* Female, DSS, 350 – 500 MCM, 17 Series Cam
SERIES 17 CAM LOCK DSS CONNECTORSX* = Color of Connector
E Black Y YellowW White O OrangeR Red H BrownG Green B Blue
34 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
CONNECTORS CABLE CARRYING STRAPS AND INDUSTRIAL STRENGTH CABLE RAMPS
APPLICATIONSGenErgy sells and stocks a wide variety of connectors in addition to those listed here. Contact customer service at 800-308-1330 for assistance with your application requirements.
Part Number Description8904H 4 AWG, Heavy-Duty, 1/2" (13mm) Single Hole
8901H 1 & 2 AWG, Heavy-Duty, 1/2" (13mm) Single Hole
8910H 1/0 AWG, Heavy-Duty, 1/2" (13mm) Single Hole
8920H 2/0 AWG, Heavy-Duty, 1/2" (13mm) Single Hole
8940H 4/0 AWG, Heavy-Duty, 1/2" (13mm) Single Hole
1/4" (6mm), 5/16" (8mm), 3/8" (10mm) hole sizes also available
COMPRESSION LUGSPart Number Description
102455 4 AWG Butt Splice, Extra Length 3.5"
102456 1 AWG/2 AWG Butt Splice, Extra Length 3.5"
102457 1/0 AWG Butt Splice, Extra Length 3.5"
102458 2/0 AWG Butt Splice, Extra Length 3.5"
102459 3/0 AWG Butt Splice, Extra Length 3.5"
102460 4/0 AWG Butt Splice, Extra Length 3.5"
BUTT SPLICES
Part Number DescriptionPT131FX20 2/0 AWG Shoo-Pin all-copper compression adapter
PT222FX40 4/0 AWG Shoo-Pin all-copper compression adapter
SHOO-PINSPart Number Description
AYP250Center Pin, Aluminum Compression Pin Adapter, 250 kcmil, 0.47" Plug Dia, 1.22" Plug Length, Al/Cu Rated, Tin Plated
AYPO250Offset Pin, Aluminum Compression Pin Adapter, 250 kcmil, 0.47" Plug Dia, 1.22" Plug Length, Al/Cu Rated, Tin Plated
OFFSET PINS AND CENTER PINS
TWIST-LOCK CONNECTORSPart Number Description Part Number Description
2311 20A, 125V, NEMA L5-20P, 2 Pole, 3-Wire, Locking Plug, Extra Heavy Duty 2611 30A, 125V, NEMA L5-30P, 2 Pole, 3-Wire, Locking Plug
2313 20A, 125V, NEMA L5-20R, 2 Pole, 3-Wire, Locking Connector 2613 30A, 125V, NEMA L5-30R, 2 Pole, 3-Wire, Locking
Connector
2321 20A, 250V, NEMA L6-20P, 2 Pole, 3-Wire, Locking Plug 2811 30A, 120/208V 3PY, NEMA L21-30P, 4 Pole, 5-Wire, Locking Plug
2323 20A, 250V, NEMA L6-20R, 2 Pole, 3-Wire, Locking Connector 2813 30A, 120/208V 3PY, NEMA L21-30R, 4 Pole, 5-Wire,
Locking Connector
2511 20A, 120/208V, NEMA L21-20P, 4 Pole, 5-Wire, Locking Plug CS636-4C 50A, 125/250VAC, Non-NEMA, 3 Pole, 4-Wire, Black &
White Locking Connector, California-Style (CS)
2513 20A, 120/208V, NEMA L21-20P, 4 Pole, 5-Wire, Locking Connector CS636-5C 50A, 125/250VAC, Non-NEMA, 3 Pole, 4-Wire, Black &
White Locking Plug, California-Style (CS)
34 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
WWW.GENERGYCABLE.COM CABLE ACCESSORIES | 35
CONNECTORS CABLE CARRYING STRAPS AND INDUSTRIAL STRENGTH CABLE RAMPS
CABLE RAMPSSecure and protect your cables from traffic and environmental concerns
Part Number Description
STRAPHANDLE 1.5" x 24" carrying strap
Part Number Description Length Width Height Weight lbs.
SlotSize
GD5X125-Y/B Guard Dog yellow and black 5 slot straight 3 ft. 36 in. 20 in. 2 in. 28 1.25 in.
GD5X125-O/B Guard Dog orange and black 5 slot straight 3 ft. 36 in. 20 in. 2 in. 28 1.25 in.
YJ5-125 Yellow Jacket® 5-channel 36 in. 20 in. 2 in. 28 1.25 in.
CARRYING STRAPS
CABLE RAMP PROTECTORS
CARRYING STRAPSCarrying and transporting cable coilswhile reducing back strain
FEATURES• Made from black reusable nylon
• Durable handle to make it easy to transport cable coils
• Measures 1.5" wide x 24" long
• Prevents cable from twisting while in use
• Sturdy construction to support up to 50 lbs.
• Ergonomically designed to reduce strain on back and hands while transporting cable
FEATURES• Industrial strength cable ramps
protect your cables
• Ideal for environments with heavy traffic
• Keep cable, hoses, and lines in place so they stay in place
• Original dog-bone connector
• Secures up to five cables
• Highly visible colors
• Designed for industrial use
• Ensure job site safety
• Capable of withstanding high volumes of traffic from commercial vehicles
36 | CABLE ACCESSORIES 800-308-1330 | MADE IN THE USA
Specifications contained herein reflect current data and are subject to change. Values are nominal and/or approximate.
HEAVY-DUTY COLLAPSIBLE CONTAINERS
STORAGE BINSOur heavy-duty collapsible containers offer easy access to job site storage materials
Part Number Description Color Dimensions Weight (lbs.)
HDBINLID Heavy-Duty Collapsible Container with Lid Black 48" X 45" X 34" 145
BINLID Heavy-Duty Lid Black 48" X 45" X 2.25" 15
BN48453420 Heavy-Duty Collapsible Container without Lid Black 48" X 45" X 34" 130
STORAGE CONTAINERS
FEATURES• Rated for load capacity up to
2500 lbs.
• Collapses in seconds and stacks for storage
• Easy access to materials through side drop panels
• Material handling accessible from all sides
• Four drain holes for better outside storage
• High strength, injection-molded, two-piece welded base interlocks into container below for secure upright or collapsed stacking
• Constructed from 100% recyclable HDPE
• Perfect for storing cable and other construction site materials
• Available with lid for additional job site security
HEAVY-DUTY COLLAPSIBLE CONTAINERS
GENERGYCABLE.COMPhone 717-584-0375 Fax 717-704-8445Toll-Free 800-308-1330
WAREHOUSESEdmonton, ABHouston, TXLancaster, PAOrlando, FL Valencia, CA
Type W Assemblies and PigtailsType PPE Assemblies and Pigtails50A Twist-Lock Extensions and Tie-InsSC Feeder Cable AssembliesSC Tie-In Sets and Pigtails5-Wire Banded Cam Lock Cable ExtensionsQuad Box AssembliesEdison Extensions/5-15 Straight Blade ExtensionsNema Wiring Device ExtensionsPin & Sleeve ExtensionsMedium VoltageType SJOOW 300V Flexible Power CordType SOOW 600V Flexible Power CordType SC 600V Entertainment CableType PPE 2000V Portable Power CableType W 2000V Power CableType W Multi-Conductor 2/C, 3/C, 4/C, 5/CType DLO (Diesel Locomotive Cable)Medium Voltage MV-105 5kV/8kVMedium Voltage MV-105 15kVJumper Cable 5kV/8kVType SH 5kV Medium Voltage Power CableType SH 15kV Medium Voltage Power CablePower Distribution BoxesConnectorsCable Carrying StrapsIndustrial Strength Cable RampsHeavy-Duty Collapsible Containers
INDUSTRIAL
Assembled Cable
Cut to Length Cable
Cable Accessories
EAST COAST HEADQUARTERS 170 EARLAND DRNEW HOLLAND, PA 17557
WEST COAST OPERATIONS 28365 CONSTELLATION ROADVALENCIA, CA 91355